wall mount handrail options - cooper industries mount handrail options ramps ramp handrail wall...

11
Wall Mount Handrail Options RAMPS Ramp handrail wall returns may be specified with a 12" extension. io requires field verified “horizontal” and “diagonal” ramp dimensions in order to generate shop drawings. Additional field dimensions may be required depending on the complexity of the handrail design. 401 E. Michigan Designer: Gary Steffy Lighting Design Photographer: Nelson Nave Mississippi River Overlook Designer: HOK Photographer: Dave Pickett 12" (0.3m) 6" (0.15m) 3.25" (83mm) Wall Return Ext. Wall Return 3.25" (83mm) 12" (0.3m) 6" (0.15m) 3.25" (83mm) Wall Return Ext. Wall Return 3.25" (83mm) Horizontal Elevation Change 6" (0.15m) 10" (0.15m) Diagonal Slope Horizontal Elevation Change Diagonal Slope STAIRS Stair handrail wall returns may be specified with a 12" extension. io requires field verified “horizontal” and “diagonal” stair dimensions in order to generate shop drawings. Additional field dimensions may be required depending on the complexity of the handrail design. io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E info@iolighting.com W iolighting.com

Upload: vodat

Post on 26-Mar-2018

217 views

Category:

Documents


1 download

TRANSCRIPT

Wall Mount Handrail Options

Ramps Ramp handrail wall returns may be specified with a 12" extension. io requires field verified “horizontal” and “diagonal” ramp dimensions in order to generate shop drawings. Additional field dimensions may be required depending on the complexity of the handrail design.

401 E. MichiganDesigner: Gary Steffy Lighting DesignPhotographer: Nelson Nave

Mississippi River Overlook Designer: HOK Photographer: Dave Pickett

12"(0.3m)

6"(0.15m)

3.25" (83mm)

Wall Return

Ext. Wall Return

3.25" (83mm)

12"(0.3m)

6"(0.15m)

3.25" (83mm)

Wall Return

Ext. Wall Return

3.25" (83mm)

Horizontal

Elevation Change

6" (0.15m)

10" (0.15m)

Diagonal

slope

Horizontal

Elevation Change

Diagonal

slope

staiRs Stair handrail wall returns may be specified with a 12" extension. io requires field verified “horizontal” and “diagonal” stair dimensions in order to generate shop drawings. Additional field dimensions may be required depending on the complexity of the handrail design.

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

Posts are chosen to match or complement your handrail selection. Posts are spaced between 4' and 5' on-center depending on specified size and alloy. Posts may be surface mounted or embedded below concrete surface and set with quick-setting grout by contractor. Base plates are optional.

Post Mount Options

Surface Mounted Embedded

Cover Flange

41⁄2"(114mm)

13⁄1

6"(2

1mm

)

1" (2

5mm

)

Clear Hole for 3⁄8" bolts(9.6mm)

31⁄4" diameterBolt Circle(82.5mm)

Flange Base

Concrete

Rocktite

slip Flange with or without set screw

1⁄2" or 3⁄4" Conduit

(13mm or 19mm)

Return to Walking Surface

Return to Post

ADA Compliant Return Options

345 Park AvenueDesigner: Jaros Baum & BollesPhotographer: Dave Pickett

Lake Forest High School Designer: Perkins & Will Photographer: Dave Pickett

Eden Roc Hotel Photographer: Dave Pickett

12" min(0.3m)

12" min(0.3m)

1 tread width

12" min(0.3m)

12" min(0.3m)

1 tread width

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

Length Options

Application Options

Standard grab bar lengths may be ordered available in nominal lengths of 2', 3', 4', and 5'.

grab bar may be customized to accommodate ADA lighting or aesthetic requirements. Submit concept sketches to io Lighting for design assistance.

standard grab bar

Custom grab bar

Custom grab bar

Railings shown are not to scale.

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

505.7.1 CiRCulaR CRoss sECtion

Handrail gripping surfaces with a circular cross section shall have an outside diameter of 11⁄4" (32mm) minimum and 2" (51mm) maximum.

The following references are taken from the 2004 Americans with Disabilities Act Accessibility Guidelines.

Capital One Designer: Oglesby Holtman DesignPhotographer: Dan Kohnen

Handrail Dimensions

Custom luxrail grab bar lengths can be specified to accommodate all ADA Compliant applications

Shower StallsBath TubsWater Closets

12"

36" min

36" min

12"

12"

54" min

54" min

17"-19"19" min 33"-36"

48" min12" max

33"-36" 33"-36"

15" max

9"

Back Wall

side Wall

With seat at Head of tub

Back

24" min12" max

33"-36"

15" max

9"33"-36"

24" min

27" max

Control area

38" min48" max

33"-36"

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

Transition Sleeve

luxrail integrates a low voltage LED-based linear light fixture within the handrail. luxrail requires a power supply to transform and regulate the voltage. This power supply is called a “driver.”

The luxrail requires that the 24v driver be remotely located. The driver must be housed in an enclosure that is rated for use in both interior and exterior applications. luxrail utilizes a compact electronic driver which is protected against open circuit, short circuit, overload and overheating conditions. It is UL recognized and FCC compliant.

Electrical

When a handrail is installed on ramps, stairs or landings 30" above finished floor – it is referred to as a “guardrail.” Handrails provide guidance, while guardrails prevent accidental falls. Guardrails have opening limitations. The most common requirement is that no opening be large enough to allow a4" sphere to pass. luxrail has two infill options to address this requirement: stainless steel cable and glass. Stainless steel cable and all required hardware are supplied with system. For glass infill option, panel clips are supplied with system; glass is supplied by others.

Glass inFill

Panel clips are used to support 1⁄4" or 1⁄2" tempered glass infill panels. Glass is provided by others.

stainlEss stEEl CaBlE inFill

Stainless steel cable railing system integrates all cable hardware inside the end posts, making it virtually invisible. The cable railing system may only be usedwith the stainless steel railing frame. Stainless steel railing hardware can be factory swaged or field swaged by the installer. Cable infill is only available for flat surfaces.

Infill Options

io Studio Photographer: Dave Pickett

Light Backing Pad

Feed Termination

Slotted Tube Insert

Secondary Feed Routed through

Wall Bracket

Light Mounting Clip

Wall Mount Bracket

io Luxrail LED Fixture

22 AWG, 300 Volt Power Cord

Wire Nut Connections within Wireway

Driver with Enclosure

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

Rubber O-ring

Glass Supported PinInstall through predrilled hole in the glass (optional)

2 1/8"(54mm)

2 1/4"(57mm)

Code Details

aCCEssiBility GuiDElinEs

Two references:1) ICC/AnSI A117.1: Accessible And Usable Buildings & Facilities2) The Americans with Disabilities Act Accessibility Guidelines (ADAAG) Note: ADA is a civil rights law – it is not a building code. However, the ADAAG has been incorporated into many state and local building codes.

illuminanCE lEvEl REquiREmEntsIBC: 1 footcandle for means of egress for emergency lighting. IRC: Light level not specified.AnSI A117: Stairways shall have 10 footcandles measured at the

center of the tread surface and on landing surfaces within 24" of step nosing.

Accessibility Code References

ICC: International Code Council

BOCA: Building Officials Code Administration

ICBO: International Conference of Building Officials

SBCCI: Southern Building Code Congress

IBC: International Building Code

IRC: International Residential Code

Prior to 2000, BOCA, SBCCI and ICBO each prepared their own model codes that were regionally applied. In 1999, these three organizations merged to form the International Code Council (ICC).

In 2000, the ICC published the International Building Code (IBC) and the International Residential Code (IRC). The IRC and the IBC model codes have since been adopted by states throughout the U.S.

AnSI Compliant Illumination Levels

Rio Hondo Pedestrian Bridge Designer: Steven Ehrlich ArchitectsPhotographer: Manuel Jaramillo

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

Sustainability io Recommends Aluminum

Handrails and GuardrailsHanDRails pRoviDE GuiDanCE

Handrails are located between 34" and 38" above stair nosings or ramp surfaces and have dimensional limitations for graspability. In areas where children are the principal users (e.g., elementary schools), the ADAAG recommends a second set of handrails be located at 28" above stair nosings or ramp surfaces.

Reference: IBC 2000, ANSI A117.1, ADAAG

GuaRDRails pREvEnt aCCiDEntal Falls

Guardrails are generally required for ramps, stairs or landings above 30". The height will vary depending on local code. The IBC requires a guardrail to be 42" in height. If a 42" guardrail is called for on a stair or ramp, it will require a handrail at a height of between 34" and 38". The IRC requires 36" high guardrails for porches, balconies and raised floor surfaces. A guard’s top rail does not have to meet the requirements for graspability if a handrail is in place.

Capital One Designer: Oglesby Holtman DesignPhotographer: Dan Kohnen

GREEn

Aluminum is one of the most sustainable materials on earth. Making up 8% of the Earth’s crust, Aluminum is one of the most plentiful elements and most preferred building material because it can be indefinitely recycled without loss of properties or quality.

DuRaBlE

Aluminum generates a protective oxide coating which makes it naturally corrosion resistant, weather proof and immune to harmful effects of UV rays. Requiring little to no maintenance, Aluminum does not absorb moisture and is saltwater resistant. It will not rust, rot, swell, warp, twist, split or crack.

RoBust

Aluminum is about one-third the weight of steel yet its tensile strength is perfect for handrails, curtain walls, window frames, wall framing systems and solar shading.

lEED

Although recycled material percentages constantly change, approximately 25% of io’s aluminum handrail comes from recycled pre-consumer aluminum.

FinisH

Aluminum can be anodized or painted in any color. Some surface finishes can offer increased durability and corrosion resistance. Consult io Lighting for details.

Clear Anodized Aluminum Caprail

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

luxrail crosses into two separate sections of the architectural specification – both as handrail which is listed in the “Miscellaneous Metals” section and as lighting which is listed in the “Electrical” section. As such, it requires two different trades for installation: an experienced handrail installer and a licensed electrician. It is important that contractors understand that luxrail must be bid on and installed by two separate trades to ensure accurate labor estimates. On some projects, architects have created an entirely new and separate section of the specification package for luxrail, spelling out exactly how the bidding and installation need to be handled.

When requesting a quote for luxrail, fully dimensioned plan and elevation drawings of each individual railing section are required. Stair and ramp elevations can be found in the Architectural details. Exterior railing locations and elevations are usually shown in the Landscape plans and details. The elevations illustrate the required style, size and features of each railing. The plan views show the location, length and quantity of rails needed. The lighting fixture schedule should also be provided as it lists the desired light output, color and distribution. From these project specific details a customized quotation is created.

After an order is placed, detailed submittal drawings are prepared and sent to the customer for approval. The submittals must be reviewed for compliance with site conditions, conformance with lighting specification and fulfillment of the electrical power requirements. This may require review by several parties.

The lead-time on luxrail fixtures begins once the signed approval drawings have been returned. Once approved, luxrail is custom fabricated to the exact project details and specifications as illustrated in the approvals.

Submittals should be reviewed with three objectives in mind:1. The handrail drawings must be reviewed for compliance to site conditions. Finished stair and ramp dimensions usually vary from the architectural plans. For this reason, actual field dimensions must be used when reviewing the submittals. This portion of the review is typically done by the handrail installer. Contact io Lighting for approved luxrail installers.

2. The LED fixture counts and run lengths must be reviewed to verify that adequate power is provided to each railing and that all remote driver restrictions have been met. This portion of the review is typically done by the electrical contractor.

3. The luxrail catalog code must be reviewed for compliance to the lighting specifications. The light output, beam spread and distribution should be verified. This portion of the review is typically done by the lighting designer.

io has a dedicated team for luxrail projects. Let us help you from design through installation.

The Specification Process

ElEvation DRaWinGs suBmittal DRaWinGs ComplEtED luxRail pRojECt

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

Power suPPlies

Key Features Recommended for long

continuous runs Suitable for dry, damp and

wet locations Built in wiring compartments

for easy installation Built in EMI Filter for low noise Class 2 w/dual 24v output

specificationsLocation: wet iP65Output Voltage: 24v DCOutput Power: 200w (96 w/channel)Input Voltage: 90 to 264 VAC Frequency: 47 to 63 HZAmbient Temp: -20˚C to +50˚CWeight: 6.61 lbsDimming: Not Available

200-Watt Driverio PArT#: Dr2ØØAM

200W Max Run Length in Series Max Run Lengths in Parallel

line .75 - SO 50' (15.24m) 111' (33.83m)line .75 - MO 23' (7.01m) 50' (15.24m)line .75 - HO and color 15’ (4.57m) 34' (10.36m)line .75 - VHO 11' (3.35m) 25' (7.62m)line 1.5 - SO 15' (4.57m) 111' (33.83m)line 1.5 - MO 7.5' (2.29m) 50' (15.24m)line 1.5 - HO 6' (1.83m) 34' (10.36m)line 1.5 - VHO 4' (1.22m) 21' (6.40m)LEDge - SO 23' (7.01m) 50' (15.24m)LEDge - HO 15' (4.57m) 34' (10.36m)luxrail - SO 50' (15.24m) 111' (33.83m)luxrail - HO and color 15' (4.57m) 34' (10.36m)line 2.0 - SO 20' (6.10m) 46' (14.02m)line 2.0 - HO 14' (4.27m) 31' (9.45m)line 2.0 - VHO 10' (3.05m) 22' (6.71m)line 2.0 - V2HO 6' (1.83m) 15' (4.57m)

2 7 7 N O T A V A I L A B L E

Input Cable Output Cable

Input CableOutput Cable

Inpu

t Cab

leOu

tput

Cab

le

5.85"(148.6mm)

3.05"(77.5mm)

1.57"(39.9mm)

15.59"(396mm)

3.94"(100mm)

Single Line Voltage Input Dual Output Channels

Note: For higher IP enclosure alternatives contact io Lighting for availability.

REMOTE DISTANCE DIAMETER

7'-0" (2.1m) w/22 AWG (.644mm)18'-0" (5.5m) w/18 AWG (1.02mm)46'-0" (14.0m) w/14 AWG (1.63mm)71'-0" (21.6m) w/12 AWG (2.05 mm)

Key Features Light weight, low profile Short circuit and overload

protection Low power supply losses

specificationsLocation: DryOutput Voltage: 24v DCOutput Power: 20wInput Voltage: 120 to 240 VAC Frequency: 50 to 60 HZAmbient Temp: -20˚C to +50˚CWeight: .21 lbsDimming: Yes w/ 250ioXFDiM

20-Watt Driverio PArT#: Dr2Øos

20W Max Run Length in Series Max Run Lengths in Parallel

line .75 - SO 11' (3.35m) 11' (3.35m)line .75 - MO 5' (1.52m) 5' (1.52m)line .75 - HO and color 3’ (.91m) 3' (.91m)line .75 - VHO 2' (.61m) 2' (.61m)line 1.5 - SO 11' (3.35m) 11' (3.35m)line 1.5 - MO 5' (1.52m) 5' (1.52m)line 1.5 - HO 3' (.91m) 3' (.91m)line 1.5 - VHO 2' (.61m) 2' (.61m)LEDge - SO 5' (1.52m) 5' (1.52m)LEDge - HO 3' (.91m) 3' (.91m)luxrail - SO 11' (3.35m) 11' (3.35m)luxrail - HO and color 3' (.91m) 3' (.91m)line 2.0 - SO 4' (1.22m) 4' (1.22m)line 2.0 - HO 3' (.91m) 3' (.91m)line 2.0 - VHO 2' (.61m) 2' (.61m)line 2.0 - V2HO 1' (.30m) 1' (.30m)

2.20"(56.0mm)

2.20"(56.0mm)

24VDC+ –

2.36"(60.0mm)

1.20"(30.5mm)

2.36"(60.0mm)

Line

Load side: use 14 AWG wire

Line side: use 12 AWG wire

Load

4 LampN L

2.36"(60.0mm)

2.20"(56.0mm)

1.2"(30.5mm)

2.36"(60.0mm)

2.20"(56.0mm)

Line

Load

24VDC+ _

Line side: use 12 AWG wire

Load side: use 14 AWG wire

Note: 6" (L) x 4" (W) x 4" (H) enclosure is requied by UL.

REMOTE DISTANCE DIAMETER

7'-0" (2.1m) w/22 AWG (.644mm)18'-0" (5.5m) w/18 AWG (1.02mm)46'-0" (14.0m) w/14 AWG (1.63mm)71'-0" (21.6m) w/12 AWG (2.05 mm) 2 7 7 N O T A V A I L A B L E

Note: 11" (L) x 4" (W) x 4" (H) enclosure is requied by UL.

Key Features UL Class 2 Ultra small, compact size Tightly regulated output:

1% line, 5% load Power factor: 90% min Total harmonic distortion:

20% max Current crest factor: 1.5 max

specificationsLocation: Damp iP66Output Voltage: 24v DCOutput Power: 100wInput Voltage: 120 to 277 VAC Ambient Temp: -40˚C to +50˚CWeight: 1.41 lbsDimming: requires 250ioXFDiM (shown above)

100-Watt Driverio PArT#: 250ioADV100

100W Max Run Length in Series Max Run Lengths in Parallel

line .75 - SO 50' (15.24m) 55' (16.76m)line .75 - MO 23' (7.01m) 25' (7.62m)line .75 - HO and color 15’ (4.57m) 17' (5.18m)line .75 - VHO 11' (3.35m) 12' (3.66m)line 1.5 - SO 15' (4.57m) 55' (16.76m)line 1.5 - MO 7.5' (2.29m) 25' (7.62m)line 1.5 - HO 6' (1.83m) 17' (5.18m)line 1.5 - VHO 4' (1.22m) 10' (3.05m)LEDge - SO 23' (7.01m) 25' (7.62m)LEDge - HO 15' (4.57m) 17' (5.18m)luxrail - SO 50' (15.24m) 55' (16.76m)luxrail - HO and color 15' (4.57m) 17' (5.18m)line 2.0 - SO 20' (6.10m) 21' (6.40m)line 2.0 - HO 14' (4.27m) 15' (4.57m)line 2.0 - VHO 10' (3.05m) 10' (3.05m)line 2.0 - V2HO 6' (1.83m) 7' (2.13m)

REMOTE DISTANCE DIAMETER

7'-0" (2.1m) w/22 AWG (.644mm)18'-0" (5.5m) w/18 AWG (1.02mm)46'-0" (14.0m) w/14 AWG (1.63mm)71'-0" (21.6m) w/12 AWG (2.05 mm)

Dimming Module io PArT#: 250ioXFDiM

io Lighting 370 Corporate Woods Pkwy Vernon Hills, IL 60061-3107 T 847.735.7000 F 847.735.7001 E [email protected] W iolighting.com

Dimming Module Key Features• Utilizes pulse width

modulation, (PWM) tocontrol LED performance

• Options available for analogor DMX control protocols

• Dimming range: 0-100%• Short circuit, overload and

overheating protection

SpecificationsLocation: DryInput Voltage: 24v DCMax. Input Current: 5.3AControl Voltage: 0-10V DCOutput Frequency: 135 HZAmbient Temp: -20C to +50CWeight: .165 lbsPower Consumption Up to 3W

.13"3.5mm3.5mm

1.65"42mm42mm

.78"20mm

6.46 ± .02"164 ± 0.3 mm164 ± 0.3 mm

6.77 ± .02"6.77 ± .02"172 ± 0.3 mm

serutxiFDEL

gnimmiDeludoM

Input Line Voltageoltage

Control signal 1...10VDC

revirDDEL

Exterior Rated Enclosure

Two dimming modules can be located in each 11"x4"x4" enclosure

Specify wire gage, and number of dimming modules.

DMX CompatibilityA DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Fluorescent Option Module will provide up to (24) 0-10V signals from a single unit. The dimming module has also been tested with a 0-10V converter from Northlight Systems.

Lutron Products

0-10 V (current sink) IEC 60929

Entire Room ControlsRadio TouchTM includedmicroWattTM includedGrafi k Eye 3000/2000 GRX-TVI 4000® TVM Module GXI includedSpacer System SPSF-6A + GRX-TVI

Building ControlsBuilding ControlsLCP128TM TVM ModuleG5000TM/6000®/7000TM TVM Module

Whole Home ControlsRadio RA® RA-6ND + GRX-TVIHomeworks® GRX-TVI, TVM

WallboxNovaT*® NTFTVNova® NFTVVareo® 2 VF10 + GRX-TVIDiva® 2 DVF103P + GRX-TVISkylark® 2 SF103P + GRX-TVI

Source: Lutron Application Note #138:

**Please contact specifi c manufacturers for details on specifi c dimming control.

Tested by OSRAM

Manufacturer Type ModelManufacturer Type ModelManufacturer Type Model

HUNT 0 - 10 wall mount PS-010Leviton 0 - 10 wall mount IP710-DLWLightolie 0 - 10 wall mount ZP600F-AM 120WLutron 0 - 10 wall mount NTFTV Series Control Panel Grafi k Eye Converter to 0- 10v dc GRX-TVI, GRX-TVMNortLight Systems DMX to 0-10v Converter 8 channels 24 channels

Source: OSRAM’s “Controllers for LED Modules” powerpoint

10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

20 30 40 50 60

Output Power in Watts

Power loss curve for OTDIM

Po

we

r Lo

ss in

Wa

tts

70 80 90 100 110 120

10V

24V

IO PART#: 250IOXFDIM

Wiring Diagram

Key Features Utilizes pulse width modulation

(PWM), to control LED performance Options available for analog

or DMX protocols Dimming range: 0-100% Short circuit, overload and

overheating protection

specificationsLocation: DryInput Voltage: 24v DCMax Input Current: 5.3AControl Voltage: 0-10v DCFrequency: 135 HZAmbient Temp: -20˚C to +50˚CWeight: .165 lbsPower Consumption: up to 3w

io Lighting 370 Corporate Woods Pkwy Vernon Hills, IL 60061-3107 T 847.735.7000 F 847.735.7001 E [email protected] W iolighting.com

Dimming Module Key Features• Utilizes pulse width

modulation, (PWM) tocontrol LED performance

• Options available for analogor DMX control protocols

• Dimming range: 0-100%• Short circuit, overload and

overheating protection

SpecificationsLocation: DryInput Voltage: 24v DCMax. Input Current: 5.3AControl Voltage: 0-10V DCOutput Frequency: 135 HZAmbient Temp: -20C to +50CWeight: .165 lbsPower Consumption Up to 3W

.13"3.5mm3.5mm

1.65"42mm42mm

.78"20mm

6.46 ± .02"164 ± 0.3 mm164 ± 0.3 mm

6.77 ± .02"6.77 ± .02"172 ± 0.3 mm

serutxiFDEL

gnimmiDeludoM

Input Line Voltageoltage

Control signal 1...10VDC

revirDDEL

Exterior Rated Enclosure

Two dimming modules can be located in each 11"x4"x4" enclosure

Specify wire gage, and number of dimming modules.

DMX CompatibilityA DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Fluorescent Option Module will provide up to (24) 0-10V signals from a single unit. The dimming module has also been tested with a 0-10V converter from Northlight Systems.

Lutron Products

0-10 V (current sink) IEC 60929

Entire Room ControlsRadio TouchTM includedmicroWattTM includedGrafi k Eye 3000/2000 GRX-TVI 4000® TVM Module GXI includedSpacer System SPSF-6A + GRX-TVI

Building ControlsBuilding ControlsLCP128TM TVM ModuleG5000TM/6000®/7000TM TVM Module

Whole Home ControlsRadio RA® RA-6ND + GRX-TVIHomeworks® GRX-TVI, TVM

WallboxNovaT*® NTFTVNova® NFTVVareo® 2 VF10 + GRX-TVIDiva® 2 DVF103P + GRX-TVISkylark® 2 SF103P + GRX-TVI

Source: Lutron Application Note #138:

**Please contact specifi c manufacturers for details on specifi c dimming control.

Tested by OSRAM

Manufacturer Type ModelManufacturer Type ModelManufacturer Type Model

HUNT 0 - 10 wall mount PS-010Leviton 0 - 10 wall mount IP710-DLWLightolie 0 - 10 wall mount ZP600F-AM 120WLutron 0 - 10 wall mount NTFTV Series Control Panel Grafi k Eye Converter to 0- 10v dc GRX-TVI, GRX-TVMNortLight Systems DMX to 0-10v Converter 8 channels 24 channels

Source: OSRAM’s “Controllers for LED Modules” powerpoint

10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

20 30 40 50 60

Output Power in Watts

Power loss curve for OTDIM

Po

we

r Lo

ss in

Wa

tts

70 80 90 100 110 120

10V

24V

IO PART#: 250IOXFDIM

Wiring Diagram

Tested by osrAM

io Lighting 370 Corporate Woods Pkwy Vernon Hills, IL 60061-3107 T 847.735.7000 F 847.735.7001 E [email protected] W iolighting.com

Dimming Module Key Features• Utilizes pulse width

modulation, (PWM) tocontrol LED performance

• Options available for analogor DMX control protocols

• Dimming range: 0-100%• Short circuit, overload and

overheating protection

SpecificationsLocation: DryInput Voltage: 24v DCMax. Input Current: 5.3AControl Voltage: 0-10V DCOutput Frequency: 135 HZAmbient Temp: -20C to +50CWeight: .165 lbsPower Consumption Up to 3W

.13"3.5mm3.5mm

1.65"42mm42mm

.78"20mm

6.46 ± .02"164 ± 0.3 mm164 ± 0.3 mm

6.77 ± .02"6.77 ± .02"172 ± 0.3 mm

serutxiFDEL

gnimmiDeludoM

Input Line Voltageoltage

Control signal 1...10VDC

revirDDEL

Exterior Rated Enclosure

Two dimming modules can be located in each 11"x4"x4" enclosure

Specify wire gage, and number of dimming modules.

DMX CompatibilityA DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Fluorescent Option Module will provide up to (24) 0-10V signals from a single unit. The dimming module has also been tested with a 0-10V converter from Northlight Systems.

Lutron Products

0-10 V (current sink) IEC 60929

Entire Room ControlsRadio TouchTM includedmicroWattTM includedGrafi k Eye 3000/2000 GRX-TVI 4000® TVM Module GXI includedSpacer System SPSF-6A + GRX-TVI

Building ControlsBuilding ControlsLCP128TM TVM ModuleG5000TM/6000®/7000TM TVM Module

Whole Home ControlsRadio RA® RA-6ND + GRX-TVIHomeworks® GRX-TVI, TVM

WallboxNovaT*® NTFTVNova® NFTVVareo® 2 VF10 + GRX-TVIDiva® 2 DVF103P + GRX-TVISkylark® 2 SF103P + GRX-TVI

Source: Lutron Application Note #138:

**Please contact specifi c manufacturers for details on specifi c dimming control.

Tested by OSRAM

Manufacturer Type ModelManufacturer Type ModelManufacturer Type Model

HUNT 0 - 10 wall mount PS-010Leviton 0 - 10 wall mount IP710-DLWLightolie 0 - 10 wall mount ZP600F-AM 120WLutron 0 - 10 wall mount NTFTV Series Control Panel Grafi k Eye Converter to 0- 10v dc GRX-TVI, GRX-TVMNortLight Systems DMX to 0-10v Converter 8 channels 24 channels

Source: OSRAM’s “Controllers for LED Modules” powerpoint

10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

20 30 40 50 60

Output Power in Watts

Power loss curve for OTDIM

Po

we

r Lo

ss in

Wa

tts

70 80 90 100 110 120

10V

24V

IO PART#: 250IOXFDIM

Wiring Diagramwiring Diagram

io Lighting 370 Corporate Woods Pkwy Vernon Hills, IL 60061-3107 T 847.735.7000 F 847.735.7001 E [email protected] W iolighting.com

Dimming Module Key Features• Utilizes pulse width

modulation, (PWM) tocontrol LED performance

• Options available for analogor DMX control protocols

• Dimming range: 0-100%• Short circuit, overload and

overheating protection

SpecificationsLocation: DryInput Voltage: 24v DCMax. Input Current: 5.3AControl Voltage: 0-10V DCOutput Frequency: 135 HZAmbient Temp: -20C to +50CWeight: .165 lbsPower Consumption Up to 3W

.13"3.5mm3.5mm

1.65"42mm42mm

.78"20mm

6.46 ± .02"164 ± 0.3 mm164 ± 0.3 mm

6.77 ± .02"6.77 ± .02"172 ± 0.3 mm

serutxiFDEL

gnimmiDeludoM

Input Line Voltageoltage

Control signal 1...10VDC

revirDDEL

Exterior Rated Enclosure

Two dimming modules can be located in each 11"x4"x4" enclosure

Specify wire gage, and number of dimming modules.

DMX CompatibilityA DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Fluorescent Option Module will provide up to (24) 0-10V signals from a single unit. The dimming module has also been tested with a 0-10V converter from Northlight Systems.

Lutron Products

0-10 V (current sink) IEC 60929

Entire Room ControlsRadio TouchTM includedmicroWattTM includedGrafi k Eye 3000/2000 GRX-TVI 4000® TVM Module GXI includedSpacer System SPSF-6A + GRX-TVI

Building ControlsBuilding ControlsLCP128TM TVM ModuleG5000TM/6000®/7000TM TVM Module

Whole Home ControlsRadio RA® RA-6ND + GRX-TVIHomeworks® GRX-TVI, TVM

WallboxNovaT*® NTFTVNova® NFTVVareo® 2 VF10 + GRX-TVIDiva® 2 DVF103P + GRX-TVISkylark® 2 SF103P + GRX-TVI

Source: Lutron Application Note #138:

**Please contact specifi c manufacturers for details on specifi c dimming control.

Tested by OSRAM

Manufacturer Type ModelManufacturer Type ModelManufacturer Type Model

HUNT 0 - 10 wall mount PS-010Leviton 0 - 10 wall mount IP710-DLWLightolie 0 - 10 wall mount ZP600F-AM 120WLutron 0 - 10 wall mount NTFTV Series Control Panel Grafi k Eye Converter to 0- 10v dc GRX-TVI, GRX-TVMNortLight Systems DMX to 0-10v Converter 8 channels 24 channels

Source: OSRAM’s “Controllers for LED Modules” powerpoint

10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

20 30 40 50 60

Output Power in Watts

Power loss curve for OTDIMP

ow

er

Lo

ss in

Wa

tts

70 80 90 100 110 120

10V

24V

IO PART#: 250IOXFDIM

Wiring Diagram

io Lighting 370 Corporate Woods Pkwy Vernon Hills, IL 60061-3107 T 847.735.7000 F 847.735.7001 E [email protected] W iolighting.com

Dimming Module Key Features• Utilizes pulse width

modulation, (PWM) tocontrol LED performance

• Options available for analogor DMX control protocols

• Dimming range: 0-100%• Short circuit, overload and

overheating protection

SpecificationsLocation: DryInput Voltage: 24v DCMax. Input Current: 5.3AControl Voltage: 0-10V DCOutput Frequency: 135 HZAmbient Temp: -20C to +50CWeight: .165 lbsPower Consumption Up to 3W

.13"3.5mm3.5mm

1.65"42mm42mm

.78"20mm

6.46 ± .02"164 ± 0.3 mm164 ± 0.3 mm

6.77 ± .02"6.77 ± .02"172 ± 0.3 mm

serutxiFDEL

gnimmiDeludoM

Input Line Voltageoltage

Control signal 1...10VDC

revirDDEL

Exterior Rated Enclosure

Two dimming modules can be located in each 11"x4"x4" enclosure

Specify wire gage, and number of dimming modules.

DMX CompatibilityA DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Fluorescent Option Module will provide up to (24) 0-10V signals from a single unit. The dimming module has also been tested with a 0-10V converter from Northlight Systems.

Lutron Products

0-10 V (current sink) IEC 60929

Entire Room ControlsRadio TouchTM includedmicroWattTM includedGrafi k Eye 3000/2000 GRX-TVI 4000® TVM Module GXI includedSpacer System SPSF-6A + GRX-TVI

Building ControlsBuilding ControlsLCP128TM TVM ModuleG5000TM/6000®/7000TM TVM Module

Whole Home ControlsRadio RA® RA-6ND + GRX-TVIHomeworks® GRX-TVI, TVM

WallboxNovaT*® NTFTVNova® NFTVVareo® 2 VF10 + GRX-TVIDiva® 2 DVF103P + GRX-TVISkylark® 2 SF103P + GRX-TVI

Source: Lutron Application Note #138:

**Please contact specifi c manufacturers for details on specifi c dimming control.

Tested by OSRAM

Manufacturer Type ModelManufacturer Type ModelManufacturer Type Model

HUNT 0 - 10 wall mount PS-010Leviton 0 - 10 wall mount IP710-DLWLightolie 0 - 10 wall mount ZP600F-AM 120WLutron 0 - 10 wall mount NTFTV Series Control Panel Grafi k Eye Converter to 0- 10v dc GRX-TVI, GRX-TVMNortLight Systems DMX to 0-10v Converter 8 channels 24 channels

Source: OSRAM’s “Controllers for LED Modules” powerpoint

10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

20 30 40 50 60

Output Power in Watts

Power loss curve for OTDIM

Po

we

r Lo

ss in

Wa

tts

70 80 90 100 110 120

10V

24V

IO PART#: 250IOXFDIM

Wiring Diagram

io Lighting 370 Corporate Woods Pkwy Vernon Hills, IL 60061-3107 T 847.735.7000 F 847.735.7001 E [email protected] W iolighting.com

Dimming Module Key Features• Utilizes pulse width

modulation, (PWM) tocontrol LED performance

• Options available for analogor DMX control protocols

• Dimming range: 0-100%• Short circuit, overload and

overheating protection

SpecificationsLocation: DryInput Voltage: 24v DCMax. Input Current: 5.3AControl Voltage: 0-10V DCOutput Frequency: 135 HZAmbient Temp: -20C to +50CWeight: .165 lbsPower Consumption Up to 3W

.13"3.5mm3.5mm

1.65"42mm42mm

.78"20mm

6.46 ± .02"164 ± 0.3 mm164 ± 0.3 mm

6.77 ± .02"6.77 ± .02"172 ± 0.3 mm

serutxiFDEL

gnimmiDeludoM

Input Line Voltageoltage

Control signal 1...10VDC

revirDDEL

Exterior Rated Enclosure

Two dimming modules can be located in each 11"x4"x4" enclosure

Specify wire gage, and number of dimming modules.

DMX CompatibilityA DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Fluorescent Option Module will provide up to (24) 0-10V signals from a single unit. The dimming module has also been tested with a 0-10V converter from Northlight Systems.

Lutron Products

0-10 V (current sink) IEC 60929

Entire Room ControlsRadio TouchTM includedmicroWattTM includedGrafi k Eye 3000/2000 GRX-TVI 4000® TVM Module GXI includedSpacer System SPSF-6A + GRX-TVI

Building ControlsBuilding ControlsLCP128TM TVM ModuleG5000TM/6000®/7000TM TVM Module

Whole Home ControlsRadio RA® RA-6ND + GRX-TVIHomeworks® GRX-TVI, TVM

WallboxNovaT*® NTFTVNova® NFTVVareo® 2 VF10 + GRX-TVIDiva® 2 DVF103P + GRX-TVISkylark® 2 SF103P + GRX-TVI

Source: Lutron Application Note #138:

**Please contact specifi c manufacturers for details on specifi c dimming control.

Tested by OSRAM

Manufacturer Type ModelManufacturer Type ModelManufacturer Type Model

HUNT 0 - 10 wall mount PS-010Leviton 0 - 10 wall mount IP710-DLWLightolie 0 - 10 wall mount ZP600F-AM 120WLutron 0 - 10 wall mount NTFTV Series Control Panel Grafi k Eye Converter to 0- 10v dc GRX-TVI, GRX-TVMNortLight Systems DMX to 0-10v Converter 8 channels 24 channels

Source: OSRAM’s “Controllers for LED Modules” powerpoint

10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

20 30 40 50 60

Output Power in Watts

Power loss curve for OTDIMP

ow

er

Lo

ss in

Wa

tts

70 80 90 100 110 120

10V

24V

IO PART#: 250IOXFDIM

Wiring Diagram

io Lighting 370 Corporate Woods Pkwy Vernon Hills, IL 60061-3107 T 847.735.7000 F 847.735.7001 E [email protected] W iolighting.com

Dimming Module Key Features• Utilizes pulse width

modulation, (PWM) tocontrol LED performance

• Options available for analogor DMX control protocols

• Dimming range: 0-100%• Short circuit, overload and

overheating protection

SpecificationsLocation: DryInput Voltage: 24v DCMax. Input Current: 5.3AControl Voltage: 0-10V DCOutput Frequency: 135 HZAmbient Temp: -20C to +50CWeight: .165 lbsPower Consumption Up to 3W

.13"3.5mm3.5mm

1.65"42mm42mm

.78"20mm

6.46 ± .02"164 ± 0.3 mm164 ± 0.3 mm

6.77 ± .02"6.77 ± .02"172 ± 0.3 mm

serutxiFDEL

gnimmiDeludoM

Input Line Voltageoltage

Control signal 1...10VDC

revirDDEL

Exterior Rated Enclosure

Two dimming modules can be located in each 11"x4"x4" enclosure

Specify wire gage, and number of dimming modules.

DMX CompatibilityA DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Fluorescent Option Module will provide up to (24) 0-10V signals from a single unit. The dimming module has also been tested with a 0-10V converter from Northlight Systems.

Lutron Products

0-10 V (current sink) IEC 60929

Entire Room ControlsRadio TouchTM includedmicroWattTM includedGrafi k Eye 3000/2000 GRX-TVI 4000® TVM Module GXI includedSpacer System SPSF-6A + GRX-TVI

Building ControlsBuilding ControlsLCP128TM TVM ModuleG5000TM/6000®/7000TM TVM Module

Whole Home ControlsRadio RA® RA-6ND + GRX-TVIHomeworks® GRX-TVI, TVM

WallboxNovaT*® NTFTVNova® NFTVVareo® 2 VF10 + GRX-TVIDiva® 2 DVF103P + GRX-TVISkylark® 2 SF103P + GRX-TVI

Source: Lutron Application Note #138:

**Please contact specifi c manufacturers for details on specifi c dimming control.

Tested by OSRAM

Manufacturer Type ModelManufacturer Type ModelManufacturer Type Model

HUNT 0 - 10 wall mount PS-010Leviton 0 - 10 wall mount IP710-DLWLightolie 0 - 10 wall mount ZP600F-AM 120WLutron 0 - 10 wall mount NTFTV Series Control Panel Grafi k Eye Converter to 0- 10v dc GRX-TVI, GRX-TVMNortLight Systems DMX to 0-10v Converter 8 channels 24 channels

Source: OSRAM’s “Controllers for LED Modules” powerpoint

10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

20 30 40 50 60

Output Power in Watts

Power loss curve for OTDIMP

ow

er

Lo

ss in

Wa

tts

70 80 90 100 110 120

10V

24V

IO PART#: 250IOXFDIM

Wiring Diagram

io Lighting 370 Corporate Woods Pkwy Vernon Hills, IL 60061-3107 T 847.735.7000 F 847.735.7001 E [email protected] W iolighting.com

Dimming Module Key Features• Utilizes pulse width

modulation, (PWM) tocontrol LED performance

• Options available for analogor DMX control protocols

• Dimming range: 0-100%• Short circuit, overload and

overheating protection

SpecificationsLocation: DryInput Voltage: 24v DCMax. Input Current: 5.3AControl Voltage: 0-10V DCOutput Frequency: 135 HZAmbient Temp: -20C to +50CWeight: .165 lbsPower Consumption Up to 3W

.13"3.5mm3.5mm

1.65"42mm42mm

.78"20mm

6.46 ± .02"164 ± 0.3 mm164 ± 0.3 mm

6.77 ± .02"6.77 ± .02"172 ± 0.3 mm

serutxiFDEL

gnimmiDeludoM

Input Line Voltageoltage

Control signal 1...10VDC

revirDDEL

Exterior Rated Enclosure

Two dimming modules can be located in each 11"x4"x4" enclosure

Specify wire gage, and number of dimming modules.

DMX CompatibilityA DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Fluorescent Option Module will provide up to (24) 0-10V signals from a single unit. The dimming module has also been tested with a 0-10V converter from Northlight Systems.

Lutron Products

0-10 V (current sink) IEC 60929

Entire Room ControlsRadio TouchTM includedmicroWattTM includedGrafi k Eye 3000/2000 GRX-TVI 4000® TVM Module GXI includedSpacer System SPSF-6A + GRX-TVI

Building ControlsBuilding ControlsLCP128TM TVM ModuleG5000TM/6000®/7000TM TVM Module

Whole Home ControlsRadio RA® RA-6ND + GRX-TVIHomeworks® GRX-TVI, TVM

WallboxNovaT*® NTFTVNova® NFTVVareo® 2 VF10 + GRX-TVIDiva® 2 DVF103P + GRX-TVISkylark® 2 SF103P + GRX-TVI

Source: Lutron Application Note #138:

**Please contact specifi c manufacturers for details on specifi c dimming control.

Tested by OSRAM

Manufacturer Type ModelManufacturer Type ModelManufacturer Type Model

HUNT 0 - 10 wall mount PS-010Leviton 0 - 10 wall mount IP710-DLWLightolie 0 - 10 wall mount ZP600F-AM 120WLutron 0 - 10 wall mount NTFTV Series Control Panel Grafi k Eye Converter to 0- 10v dc GRX-TVI, GRX-TVMNortLight Systems DMX to 0-10v Converter 8 channels 24 channels

Source: OSRAM’s “Controllers for LED Modules” powerpoint

10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

20 30 40 50 60

Output Power in Watts

Power loss curve for OTDIM

Po

we

r Lo

ss in

Wa

tts

70 80 90 100 110 120

10V

24V

IO PART#: 250IOXFDIM

Wiring Diagram

io Lighting 370 Corporate Woods Pkwy Vernon Hills, IL 60061-3107 T 847.735.7000 F 847.735.7001 E [email protected] W iolighting.com

Dimming Module Key Features• Utilizes pulse width

modulation, (PWM) tocontrol LED performance

• Options available for analogor DMX control protocols

• Dimming range: 0-100%• Short circuit, overload and

overheating protection

SpecificationsLocation: DryInput Voltage: 24v DCMax. Input Current: 5.3AControl Voltage: 0-10V DCOutput Frequency: 135 HZAmbient Temp: -20C to +50CWeight: .165 lbsPower Consumption Up to 3W

.13"3.5mm3.5mm

1.65"42mm42mm

.78"20mm

6.46 ± .02"164 ± 0.3 mm164 ± 0.3 mm

6.77 ± .02"6.77 ± .02"172 ± 0.3 mm

serutxiFDEL

gnimmiDeludoM

Input Line Voltageoltage

Control signal 1...10VDC

revirDDEL

Exterior Rated Enclosure

Two dimming modules can be located in each 11"x4"x4" enclosure

Specify wire gage, and number of dimming modules.

DMX CompatibilityA DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Fluorescent Option Module will provide up to (24) 0-10V signals from a single unit. The dimming module has also been tested with a 0-10V converter from Northlight Systems.

Lutron Products

0-10 V (current sink) IEC 60929

Entire Room ControlsRadio TouchTM includedmicroWattTM includedGrafi k Eye 3000/2000 GRX-TVI 4000® TVM Module GXI includedSpacer System SPSF-6A + GRX-TVI

Building ControlsBuilding ControlsLCP128TM TVM ModuleG5000TM/6000®/7000TM TVM Module

Whole Home ControlsRadio RA® RA-6ND + GRX-TVIHomeworks® GRX-TVI, TVM

WallboxNovaT*® NTFTVNova® NFTVVareo® 2 VF10 + GRX-TVIDiva® 2 DVF103P + GRX-TVISkylark® 2 SF103P + GRX-TVI

Source: Lutron Application Note #138:

**Please contact specifi c manufacturers for details on specifi c dimming control.

Tested by OSRAM

Manufacturer Type ModelManufacturer Type ModelManufacturer Type Model

HUNT 0 - 10 wall mount PS-010Leviton 0 - 10 wall mount IP710-DLWLightolie 0 - 10 wall mount ZP600F-AM 120WLutron 0 - 10 wall mount NTFTV Series Control Panel Grafi k Eye Converter to 0- 10v dc GRX-TVI, GRX-TVMNortLight Systems DMX to 0-10v Converter 8 channels 24 channels

Source: OSRAM’s “Controllers for LED Modules” powerpoint

10

0

0.5

1

1.5

2

2.5

3

3.5

4

4.5

20 30 40 50 60

Output Power in Watts

Power loss curve for OTDIM

Po

we

r Lo

ss in

Wa

tts

70 80 90 100 110 120

10V

24V

IO PART#: 250IOXFDIM

Wiring Diagram

DMX Compatibility A DMX to 0-10V converter will typically be required to interface with DMX control systems. ETC has tested the dimming module with the Unison Series Dimming Rack. The Unison Flourescent Option Module will provide up to (24) 0-10 signals from a single unit. The dimming module has also been tested with a 0-10 converter from Northlight Systems.

Mississippi River OverlookDesigner: HOKPhotographer: Dave Pickett

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com

io Lighting 1100 Busch Pkwy Buffalo Grove, IL 60089 T 847.777.3900 F 847.777.3901 E [email protected] W iolighting.com