PROJ. #: DRAWN BY: SCALE: DATE: GARLAND ® AS NOTED 04/13/2021 COVERSHEET A-001 DRAWING INDEX A-001 COVERSHEET A-101 ROOF PLAN CITY of CUYAHOGA FALLS LIMIT OF WORK PROJECT AERIAL VIEW CITY of CUYAHOGA FALLS 2028 Munroe Falls Avenue Cuyahoga Falls, OH 44221 2028 Munroe Falls Avenue, Cuyahoga Falls, OH 44221 WATER PLANT ROOF WATER PLANT ROOF A-501 ROOF DETAILS ENLARGED AERIAL VIEW

Upload: others

Post on 23-Nov-2021

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: WATER PLANT ROOF - Cuyahoga Falls

PROJ. #:

DRAWN BY:

SCALE:

DATE:

GARLAND®

AS NOTED

04/13/2021

COVERSHEET

A-001

DRAWING INDEX

A-001 COVERSHEET

A-101 ROOF PLAN

CITY of CUYAHOGA FALLS

LIMIT OF WORK

PROJECT AERIAL VIEW

CITY of

CUYAHOGA FALLS

2028 Munroe Falls Avenue

Cuyahoga Falls, OH 44221

2028 Munroe Falls Avenue, Cuyahoga Falls, OH 44221

WATER PLANT ROOF

WATER PLANT ROOF

A-501 ROOF DETAILS

ENLARGED AERIAL VIEW

AutoCAD SHX Text
s
AutoCAD SHX Text
i
AutoCAD SHX Text
n
AutoCAD SHX Text
e
AutoCAD SHX Text
8
AutoCAD SHX Text
c
AutoCAD SHX Text
1
AutoCAD SHX Text
9
AutoCAD SHX Text
5
brendan.grady
Stamp
Page 2: WATER PLANT ROOF - Cuyahoga Falls

30'-0" 30'-0" 30'-0"

16

'-0

"

5'-0

"

11'-0"

21

'-0

"

RD RD RD RD RD RD

ROOF N.I.C.

19'-0"

ROOF HATCH

CURB DETAIL

COUNTER FLASHING DETAIL COUNTER FLASHING DETAIL

COPING CAP DETAIL

COPING CAP DETAIL

COPING CAP DETAIL

PROJ. #:

DRAWN BY:

SCALE:

DATE:

GARLAND®

AS NOTED

04/13/2021

ROOF PLAN

A-101

1

A-101

ROOF PLAN

SCALE: N.T.S.

1.) IT IS THE ROOFING CONTRACTOR'S RESPONSIBILITY TO

FAMILIARIZE THEMSELVES WITH ALL DETAILS INVOLVED IN THE

ROOFING CONTRACT.

2.) ALL DRAWINGS ARE GRAPHIC REPRESENTATION OF

APPROXIMATE LOCATIONS OF EXISTING AND NEW MATERIALS. IT

IS THE CONTRACTOR'S RESPONSIBILITY TO VERIFY ALL EXISTING

CONDITIONS PRIOR TO COMMENCEMENT OF WORK.

3.) THE ROOFING CONTRACTOR TO PROTECT ALL ADJACENT

SURFACES NOT SCHEDULED FOR WORK AND TO REPAIR ANY

DAMAGED AREAS AS A RESULT OF CONTRACTOR WORK AT NO

ADDITIONAL COST TO THE OWNER.

4.) THE ROOFING CONTRACTOR SHALL BE RESPONSIBLE TO

MAINTAIN WATER TIGHTNESS AND PROVIDE PROTECTION AT

ANY/ALL OPENINGS IN THE ROOF LEFT AT THE END OF EACH

CONSTRUCTION DAY.

5.) CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS,

CONDITIONS AND QUANTITIES.

GENERAL NOTES:

2

A-101

TYPICAL ROOF SECTION GRAVEL FINISH

SCALE: N.T.S.

3

A-101

AIR HANDLING UNIT DETAIL

SCALE: N.T.S.

CITY of

CUYAHOGA FALLS

2028 Munroe Falls Avenue

Cuyahoga Falls, OH 44221

WATER PLANT ROOF

AutoCAD SHX Text
s
AutoCAD SHX Text
i
AutoCAD SHX Text
n
AutoCAD SHX Text
e
AutoCAD SHX Text
8
AutoCAD SHX Text
c
AutoCAD SHX Text
1
AutoCAD SHX Text
9
AutoCAD SHX Text
5
brendan.grady
Stamp
Page 3: WATER PLANT ROOF - Cuyahoga Falls

PROJ. #:

DRAWN BY:

SCALE:

DATE:

GARLAND®

AS NOTED

04/13/2021

ROOF DETAILS

A-501

1

A-501

CURB AT AIR HANDLING STATION DETAIL

SCALE: N.T.S.

2

A-501

ROOF HATCH DETAIL

SCALE: N.T.S.

3

A-501

PIPE PENETRATION DETAIL

SCALE: N.T.S.

4

A-501

ROOF DRAIN DETAIL

SCALE: N.T.S.

5

A-501

ROOF DRAIN RETROFIT DETAIL

SCALE: N.T.S.

6

A-501

SURFACE MOUNTED COUNTERFLASHING DETAIL

SCALE: N.T.S.

CITY of

CUYAHOGA FALLS

2028 Munroe Falls Avenue

Cuyahoga Falls, OH 44221

WATER PLANT ROOF

AutoCAD SHX Text
s
AutoCAD SHX Text
i
AutoCAD SHX Text
n
AutoCAD SHX Text
e
AutoCAD SHX Text
8
AutoCAD SHX Text
c
AutoCAD SHX Text
1
AutoCAD SHX Text
9
AutoCAD SHX Text
5
brendan.grady
Stamp
Page 4: WATER PLANT ROOF - Cuyahoga Falls
Page 5: WATER PLANT ROOF - Cuyahoga Falls
Page 6: WATER PLANT ROOF - Cuyahoga Falls

15.5 Zone 2 psf 26.1 39.3

3 ft. 0 in.

Fastener Safety Factor 3.00

IV

1

120

ASCE 7-10

B

20.00

Minimum Building Width 16.00

Roof Pitch (X, Y) 0.13 : 12

Zone 2(eaves, ridge,

hip)

If you have any questions, please call 800-321-9336 or respond to [email protected]

System Type:

NOTES:

*Unless specifically stated otherwise, these calculations are based on

ASCE 7-10 (American Society for Civil Engineers); if a specific building code is required, please specify.

*It is recommended to include the "Negative Uplift Pressures" in the specifications as well as the Safety

Factor, Importance Factor, Building Category, Wind Speed, Ultimate Pullout Value, and Exposure.

EDGE SECUREMENT: Edge metal system must be ANSI/SPRI ES-1 compliant, as required by

section 1504.5 of International Building Code. Edge metal system may be an ANSI/SPRI ES-1

*The Wind Speed is determined based upon geographical location.

*The Exposure and Importance Factors are needed to determine the uplift pressures.

The Garland Company, Inc.

Low Slope Roofing Wind Uplift Calculations

3800 East 91st Street

Cleveland, Ohio 44105-2197

Phone: (800) 321-9336 Fax (216) 883-2046

Roof

Water Plant Roof

Pump Station

Project

Sales Rep. Matt McGonigal Location Cuyahoga Falls, OH

System Type:

Edge Zone Width "a"

Importance Factor

Design Roof

Importance

Exposure Category

Zone 3

Attachment Method: Mech/ Fasten Surfacing:

__ fasteners per 4' x

8' board(mid roof) (corners)

Zone 1

Mineral Surface

__ fasteners per 4' x

8' board

__ fasteners per 4' x

8' board

Zone 1 psf

Modified Bitumen Hot

(eaves, ridge, hip)

Modified Bitumen

Design Methodology

Zone 3 psf

(corners)(mid roof)

Wind Speed

3800 East 91st Street, Cleveland, Ohio 44105-2197 Phone: (800) 321-9336

Page 7: WATER PLANT ROOF - Cuyahoga Falls

PROJECT Water Plant Roof

ROOF SECTION Pump Station

DATE 4/12/2021

BASIC VELOCITY PRESSURE 21.95 psf

DESIGN CODE ASCE 7-10

SYSTEM TYPE BASIC WIND SPEED 120 mph

SYSTEM SCOPE EXPOSURE CATEGORY B

SURFACING TOPOGRAPHY FACTOR 1.00

ATTACHMENT METHOD BUILDING TYPE

SUBSTRATE MATERIAL ROOF PITCH (X, Y) 0.13 12

SUBSTRATE THICKNESS 22 gauge RUN TO RIDGE 8

FASTENER TYPE EAVE HEIGHT 20

FASTENER SAFETY FACTOR 3 DESIGN ROOF HEIGHT 20.00 ft

ULTIMATE FASTENER PULLOUT 456 lbs/screw IMPORTANCE CLASS / FACTOR IV 1

ALLOWABLE FASTENER PULLOUT 152 lbs/screw MIN. BLDG WIDTH 16 ft

WIND-BORNE DEBRIS REGION

PARAPET No

ROOF ANGLE 0.62 deg

PROTECTED OPENINGS Yes

ROOF TYPE

ZONE 1 ZONE 2 ZONE 3 ZONE 4 ZONE 5

ROOF PRESSURE (psf) 15.5 26.1 39.3 15.4 19.0

OVERHANG PRESSURE (psf) 22.39 22.39 36.88

EDGE ZONE WIDTH "a" = 3.00 ft 1.6 0.64 3

No

Modified Bitumen Hot

Mech/ Fasten Insul/Board

Gable

Steel: OMG Standard

Steel

Building & Site Data

Enclosed

System & Attachment Data

Modified Bitumen

Mineral Surface