Equipment modernization package APPLICATION The HS-200 PT RO Processor is specifically designed to supply treated water for point-of-use electric steam generators to significantly reduce or eliminate boiler scaling and to extend peak equipment performance. This unit is intended for use with a single sterilizer/electric boiler combination – with boilers in the range of 12 to 30 KW. FEATURES • Universal mounting system for quick, easy
installation. • Attractive Stainless Steel Cabinet. • Small size (24”x16”x20”) permits installation
virtually anywhere. BENEFITS • Requires service connection to cold / hot water
supply and drain. No electrical requirement. • Extended life from boiler heating element. • Increased reliability – fewer equipment breakdowns
due to boiler scaling. • Convenient quarterly maintenance intervals with
economical PM packages available.
SPECIFICATIONS • Provides 5-50 TDS output water from potable
water sources up to 2000 TDS, 250 ppm or 14 grains hardness.
PM package (available separately) Includes a year’s supply of consumable components.
Watts Modernization Package HS-200 PT
Reverse Osmosis Processor Getinge Part #61301605522
MATERIALS AND SERVICES SUPPLIED Self contained RO Processor including filters, housings, pressure tank, bypass valve and permeate pumps in a stainless steel cabinet. Includes connection to equipment. WARRANTY Watts HS-200 PT systems are warranted for one year. Labor for repairs is provided for 90 days following installation and start-up. Warranty repairs will be performed Monday through Friday, 8am to 5pm, excluding weekends and Holidays.
HS-200 PT Installation Instructions Refer to drawing A2 in this brochure for mounting instructions, minimum service clearances and service connections. Utility Requirements: Note: A floor drain within 10 feet of the Boiler Mate is required. ½” potable cold water supply – 2gpm, 45-110 degrees F, 50 – 90 psig - 2000TDS, 250ppm or 14 grains hardness Operation Once all service and output connections are made, simply turn on cold water supply to the unit. Maintenance Quarterly - Replace pre-filters – items # 1, 2, 3, & 8. Annually - Replace membrane cartridges – item# 4. Replacement Parts PM Package –Part# 501020 PM package includes a 1 year supply of Items #1, 2, 3, 4 & 8 Individual part numbers for component parts – refer to drawing A1 in this brochure. (Front view with access panel removed)
1
1
2
2
3
3
4
4
A A
B B
C C
D D
TITLE
SIZE DWG NO REV
SCALESHEET OF
DRAWN
CHECKED
QA
MFG
APPROVED
M200 Installation Specifications
M-2001 1
07/07/03C
Watts PremierCraig Schmitt 7/8/2003
M-200 PROCESSOR SPECIFICATIONS1) INLET WATER: MUST BE POTABLEWATER THAT IS MICROBIOLOGICALLY SAFE.2) CONNECTIONS: 1,2 & 3 ARE 1/2" NPT; L GRADE COPPERWITH FLAIRED FITTINGS REQUIRED.3) PRESSURE: MIN. 40 PSI, MAX 90 PSI (OPTIMUM 65 PSI)PRESSURE REGULATOR P/N 134030 REQUIREDIF OVER 90 PSI.4) PH RANGE: 4-7 PPM.5) HARDNESS: MAXIMUM 10 GRAINS OR 171 PPM.6) TEMPRATURE: MIN 40 DEG. F MAX 100 DEG. F (OPTIMUM 77 DEG. F).7) TDS: MAXIMUM 1200 PPM OR 500mg/L NaCl8) First year preventitive maintenance kit included. (P/N 501020)9) CLEARANCE: MINIMUM 18" SERVICE CLEARANCE ON SIDES D & C, MINIMUM 35" ON SIDE A.10) FLOOR DRAIN REQUIREMENTS: MIN. 1/2" DIA. WITHIN 10' OF PROCESSING UNIT.
SOURCE OF SUPPLY: PROCESSOR P/N 570200MFG: Watts Pure Water
Phoenix, AZ USA
9.50 9.50
24.00
22.00
14.0016.07
1.50
13.00
16.02
21.15
20.00
24.00
22.00
(1) PERMEATE WATER CONNECTION (1/2" NPT)
(2) CONCENTRATE WATER CONNECTION (1/2" NPT)
(3) FEED WATER CONNECTION (1/2" NPT)
LEFT SIDE B FRONT (ACCESS PANEL SIDE) A
TOP VIEW (ACCESS PANEL) D
RIGHT SIDE AIR VALVE ACCESS PANEL CTANK NEEDS TO BE EMPTY WHEN CHARGING
TO THE REQUIRED 15 P.S.I.
BOLT HOLES FOR CEILING MOUNT (4 PLACES)3/8" THREAD STOCK WITH WASHERS AND
LOCK NUTS REQUIRED
MANUAL BYPASS VALVE FOR RAPID STARTUP / BOILER FILL.
Rods run throughcabinet @ all four corners.
Nylon lock nuts & flat washerslock rods at top & bottomof M-200 enclosure
Threaded rods attached to ceiling
Threaded Rod
Flat Washer
Nylon Lock Nut
Metal or wood stud
Rear panel
Mounting holesfor stud attachmenton 18” or 16” centers
18”
16”
Bottom panel
California Code requiresfour sizemic mounting holesfor floor attachment
Equipment Outlet
(Product Water)
DrainOutlet
TapwaterInlet
Air Tank Access
Four AdjustableLeveler Feet
NOTE:Need access to front panel and right side “Air Tank Access Cap” .Recommended:Front Panel Access - 18” clearanceSide Panel Access - 12” clearnace
Panel Cover
ACCESSAREA
ACCESSAREA
18”
24”
16”
20-1/4”
12”
17.8762.063
16.36
3.062
1.95
%%c.50
20.25
Rear View
E
E
E
E
E
E
2
5
3
6
1
4
24.00
14.00
22.00
9.50 9.50 2.50
1.00
1.09
%%c.50
Top View
A
DD
DD
2
3
4
1
B C
%%c2.50
6.3
5.94Side View
10.94 10.94 1.062
7.00
7.00
%%c.375
Bottom View
G
G G
G
1
2 3
4
D
C
3 4
B
D
E
FDWG NO.
REVISION
DO NOT SCALE DRAWING
WEIGHT:
MATERIAL:
DATENAME
Q.A
DRAWN
1 2
E
D
A
B
C
21 43
C
3 4
B
D
E
FDWG NO.
REVISION
DO NOT SCALE DRAWING
WEIGHT:
MATERIAL:
DATENAME
Q.A
DRAWN
1 2
E
D
A
B
C
21 43
TAPWATERINLET
EQUIPMENTOUTLET
DRAINOUTLET
PERMIN
PERMIN
BRINEIN
BRINEOUT
BRINEOUT
BRINEOUT
BRINEIN
BRINEIN
PERMOUT
PERMOUT
PERMOUT
PERMIN
PERMIN
1
9
2 3
10
5 5 5
4 4 4
6 6 67
8
X
GREEN TUBING
BLACK TUBING
BLACK > BLACK >
BLA
CK
TU
BIN
G
BLA
CK
BLACK
BLU
E
BLU
E
BLU
E
BLU
E
BLU
E
BLU
E BLA
CK
BLA
CK
TU
BIN
G
BLA
CK
TU
BIN
G
BLA
CK
TU
BIN
G
E4
E2E1
E3
AA
ITEMITEM DESCRIPTIONPART NUMBER
1
2
3
4
5
6
7
8
9
1010
A
B
C
D
D1-D4
E1-E4
H1-H6
G1-G4
G1-G4
107021
107024
101011
210000
222019
152002
219002
307020
234010
134028
5 MICRON SEDIMENT FILTER
GAC/KDF
10 MICRON CARBON BLOCK
MEMBRANE TFM 100 GPD
750 ML FLOW RESTRICTOR
PERMEATE PUMP WITH CLIP
PRESSURE TANK
ALL CALCITE
1/2” BRASS CHECK VALVE
1/2” BY PASS VALVE
ON UNIT CONNECTION SIZE APPROVED MATERIAL
PERMEATE WATER TO BOILER
DRAIN WATER CONNECTION
INLET “COLD” WATER CONNECTION
AIR TANK ACCESS
MOUNTING LOCATION
CEILING MOUNT ( TOP PANEL )
CEILING MOUNT ( BOTTOM PANEL )
WALL MOUNT
FLOOR MOUNT
FLOOR MOUNT FOR SEISMIC STATES
1/2” FPT
1/2” FPT
1/2” FPT
2 1/2” OPENING
SIZE
3/8”
3/8”
3/8”
3/8”
3/8”
1/2” L COPPER ( SWEAT OR FLAIR )
1/2” L COPPER/PVC/POLY PROPYLENE
1/2” L COPPER/PVC/POLY PROPYLENE
TIRE PRESSURE GAUGE 0-50 PSI RANGE
APPROVED MATERIAL
THREADED STOCK
THREADED STOCK
5/16” X 2 1/2”
LEG GUIDE ( PROVIDED )/HILTI
HILTI ANCHORS (3/8” X 3 1/2” )
304 Stainless Steel
77 LBS
304 Stainless Steel
M-200-1
7/15/02
A1
TITLE: M-200 BoilerMate
7/18/02
7/18/02
7/18/02
7/18/02
ENG.
PROD.
SALES
A2
TITLE: M-200 BoilerMate
M-200-1
7/15/02
ENG.
PROD.
SALES
7/18/02
7/18/02
7/18/02
7/18/02
7/18/02
77 LBSNELSON A.
SCHMITT C.
HENSS M.
HANFORD J.
MANGIN P.
NELSON A.
SCHMITT C.
HENSS M.
HANFORD J.
MANGIN P. 7/18/02
Rods run throughcabinet @ all four corners.
Nylon lock nuts & flat washerslock rods at top & bottomof M-200 enclosure
Threaded rods attached to ceiling
Threaded Rod
Flat Washer
Nylon Lock Nut
Metal or wood stud
Rear panel
Mounting holesfor stud attachmenton 18” or 16” centers
18”
16”
Bottom panel
California Code requiresfour sizemic mounting holesfor floor attachment
Equipment Outlet
(Product Water)
DrainOutlet
TapwaterInlet
Air Tank Access
Four AdjustableLeveler Feet
NOTE:Need access to front panel and right side “Air Tank Access Cap” .Recommended:Front Panel Access - 18” clearanceSide Panel Access - 12” clearnace
Panel Cover
ACCESSAREA
ACCESSAREA
18”
24”
16”
20-1/4”
12”
17.8762.063
16.36
3.062
1.95
%%c.50
20.25
Rear View
E
E
E
E
E
E
2
5
3
6
1
4
24.00
14.00
22.00
9.50 9.50 2.50
1.00
1.09
%%c.50
Top View
A
DD
DD
2
3
4
1
B C
%%c2.50
6.3
5.94Side View
10.94 10.94 1.062
7.00
7.00
%%c.375
Bottom View
G
G G
G
1
2 3
4
D
C
3 4
B
D
E
FDWG NO.
REVISION
DO NOT SCALE DRAWING
WEIGHT:
MATERIAL:
DATENAME
Q.A
DRAWN
1 2
E
D
A
B
C
21 43
C
3 4
B
D
E
FDWG NO.
REVISION
DO NOT SCALE DRAWING
WEIGHT:
MATERIAL:
DATENAME
Q.A
DRAWN
1 2
E
D
A
B
C
21 43
TAPWATERINLET
EQUIPMENTOUTLET
DRAINOUTLET
PERMIN
PERMIN
BRINEIN
BRINEOUT
BRINEOUT
BRINEOUT
BRINEIN
BRINEIN
PERMOUT
PERMOUT
PERMOUT
PERMIN
PERMIN
1
9
2 3
10
5 5 5
4 4 4
6 6 67
8
X
GREEN TUBING
BLACK TUBING
BLACK > BLACK >
BLA
CK
TU
BIN
G
BLA
CK
BLACK
BLU
E
BLU
E
BLU
E
BLU
E
BLU
E
BLU
E BLA
CK
BLA
CK
TU
BIN
G
BLA
CK
TU
BIN
G
BLA
CK
TU
BIN
G
E4
E2E1
E3
AA
ITEMITEM DESCRIPTIONPART NUMBER
1
2
3
4
5
6
7
8
9
1010
A
B
C
D
D1-D4
E1-E4
H1-H6
G1-G4
G1-G4
107021
107024
101011
210000
222019
152002
219002
307020
234010
134028
5 MICRON SEDIMENT FILTER
GAC/KDF
10 MICRON CARBON BLOCK
MEMBRANE TFM 100 GPD
750 ML FLOW RESTRICTOR
PERMEATE PUMP WITH CLIP
PRESSURE TANK
ALL CALCITE
1/2” BRASS CHECK VALVE
1/2” BY PASS VALVE
ON UNIT CONNECTION SIZE APPROVED MATERIAL
PERMEATE WATER TO BOILER
DRAIN WATER CONNECTION
INLET “COLD” WATER CONNECTION
AIR TANK ACCESS
MOUNTING LOCATION
CEILING MOUNT ( TOP PANEL )
CEILING MOUNT ( BOTTOM PANEL )
WALL MOUNT
FLOOR MOUNT
FLOOR MOUNT FOR SEISMIC STATES
1/2” FPT
1/2” FPT
1/2” FPT
2 1/2” OPENING
SIZE
3/8”
3/8”
3/8”
3/8”
3/8”
1/2” L COPPER ( SWEAT OR FLAIR )
1/2” L COPPER/PVC/POLY PROPYLENE
1/2” L COPPER/PVC/POLY PROPYLENE
TIRE PRESSURE GAUGE 0-50 PSI RANGE
APPROVED MATERIAL
THREADED STOCK
THREADED STOCK
5/16” X 2 1/2”
LEG GUIDE ( PROVIDED )/HILTI
HILTI ANCHORS (3/8” X 3 1/2” )
304 Stainless Steel
77 LBS
304 Stainless Steel
M-200-1
7/15/02
A1
TITLE: M-200 BoilerMate
7/18/02
7/18/02
7/18/02
7/18/02
ENG.
PROD.
SALES
A2
TITLE: M-200 BoilerMate
M-200-1
7/15/02
ENG.
PROD.
SALES
7/18/02
7/18/02
7/18/02
7/18/02
7/18/02
77 LBSNELSON A.
SCHMITT C.
HENSS M.
HANFORD J.
MANGIN P.
NELSON A.
SCHMITT C.
HENSS M.
HANFORD J.
MANGIN P. 7/18/02
Model HS-200 Boiler Mate # 570200 Replacement Parts
Item # Item Description Qty per unit
61301605453 Permeate Pump 361301605455 Membrane Filter 361301605473 Flow Restrictor 750 ml 361301605471 5 Gal Storage tank 161301605449 Filter Sediment 5 micron 161301605447 Filter Carbon Block 5 micron 161301605450 Filter GAC/KDF 161301605516 Filter Calcite 161301605476 Valve Check 1/2" Brass 261301605474 Valve Ball 1/2" Brass 161301605518 HS-200 Unit PM Kit 1
1 A BOX-FILTERPAK PACK CARDBOARD SHEET WHT15.5 X 9.625 32 ECT GETIN 4.0000 EA
2 A BOX-HS333 PACK BOX 28X28X26 FORHS-333 1.0000 EA
3 A BOX-HS333-PLY PACK HS333 PLYWOOD INSERT 1.0000 EA
4 A FOAM-HS333 PACK FOAM CORNER PADS FORHS333 UNIT 8.0000 EA
5 C2500W RO MOUNTING CLIP SINGLE2 1/2" WHITE 6.0000 EA
6 CI061208W FTG 3/8 - 1/4 REDUCER WHITE 1.0000 EA
7 ERP-1000 PUMP AQUATEC PERMEATE PUMP UP TO 100 GPD/NON ELEC 3.0000 EA
8 F10-4-6-N-O FTG JACO MALE CONNECTOR 1/4" NUT X 3/8" MNPT 3.0000 EA
9 F107021 SED-5M-Q SERIES Q/C-14" 4.0000 EA
10 F107024 KDF HS-333 Q-SERIES-14" 4.0000 EA
11 F107027 HOUSING-LID-Q SER-3/8"F-VLV HD 4.0000 EA
12 F110000 ROM - 100 GPD MEMBRANE 3.0000 EA
13 F125062 TEE-PL-M-RUN-3/8MPTX1/2C 1.0000 EA
14 F125089 ELB-1/4FQCX1/4MQC-PLASTICWHITE 12.0000 EA
15 F134015 RO CHECK VALVE FOR MANIFOLD 6.0000 EA
16 F219002 TANK PRESSURE (RP-5) 105 1.0000 EA
17 F222019 FLOW RESTRICTOR-750ML/M-STD 3.0000 EA
18 F231023 SLEEVE-DELRIN-1/2-PL 14.0000 EA
19 F231029 INSERT-BR-1/2 14.0000 EA
20 F231055 HEX NIPPLE-BR-1/2MX1/4M-REDUCR 1.0000 EA
21 F231095 CON-BR-1/2CX1/2M 2.0000 EA
22 F231098 CON-BR-1/2CX3/4M 1.0000 EA
23 F231152 ELB-BR-1/2Cx3/8M-90 3.0000 EA
24 F231155 ELB-BR-1/2CX1/2M-90 2.0000 EA
25 F231179 TEE-BR-1/2C ALL 2.0000 EA
26 F231194 FTG ELBOW BR 3/4"F X 3/4"F 90 1.0000 EA
27 F231272 ADAPT-BR-BULKHEAD-1/2F 3.0000 EA
28 F234010 VALVE-CHECK-BR-1/2F-#6 2.0000 EA
29 F234058 VALVE-BLENDING 1/2"NPT 60-120 1.0000 EA
30 F237002 BRACKET-SINGLE-Q SERIES-14 GA 1.0000 EA
31 F237023 FRAME-M200 SS BOX 1.0000 EA
32 F240024 CAP PLUG 8X- M200 3.0000 EA
33 F246002 INSERT 1/4-20 4.0000 EA
34 F246033 BOLT-DOME-1/4-20x1/2"L-PHIL-SS 2.0000 EA
35 F246081 NUT-1/4-20 HEX FINISH STAR LOC 4.0000 EA
36 F249019 LEG-GLIDE-1/4-20 4.0000 EA
37 F261008-NP GAUGE 0-200 PRESSURE/TEMP2.5 CENTER BACK MOUNT NO 1.0000 EA
38 F264013 PLUG-NYLON-BLACK-2.5" 1.0000 EA
39 F299120 MANUAL-HS200 1.0000 EA
40 F299300 STICKER BOILER MATE 1.0000 EA
41 F299301 LABELS-KIT-INFO-M200-2-1/2X1/2 1.0000 EA
42 F299600 LABEL-MEMBRANE-GETINGE-GREEN#4 3.0000 EA
43 F299609 LABELS-KIT-FILT-#'S-HS20-41279 1.0000 EA
44 F299610 LABEL-GETINGE-BRINE & PERMEATE 3.0000 SET
570200 HS-200 PT BOM
45 F299611 LABEL-FILTER-GET-CB-BLACK-#3 4.0000 EA
46 F299620 LABEL-FILTER-GET-TDS/PH-BL-#5 4.0000 EA
47 F299621 LABEL-FILTER-GET-SED-RED 4.0000 EA
48 F299624 LABEL-FILTER-GET-KDF-6LB-GLD#2 4.0000 EA
49 F307020 PH/TDS BALANCER-Q SERIES-6" 4.0000 EA
50 F334001 FTG BALL VALVE BRASS 1/2"FXF 1.0000 EA
51 FMPE-14-L-500 TUB FLOWMATIC 1/4" P.E. TUBING BLUE 500FT 0.0010 ROLL
52 I35216P-6 PLB NIPPLE HEX BRASS .375" 25/BX 4.0000 EA
53 I35216P-8 PLB NIPPLE HEX BRASS .50"10/BX 4.0000 EA
54 I352200P-6-6 PLB ELBOW BRASS .375" FXF PARKER 1.0000 EA
55 I352203P-4 PLB TEE BRASS .25" FXFXF25/BX PARKER 1.0000 EA
56 I352203P-6 PLB TEE BRASS .375" FXFXF PARKER 2.0000 EA
57 I352203P-8 PLB TEE BRASS .50" FXFXFPARKER 1.0000 EA
58 I8080 TUBING POLYETHYLENE .50"OD LD BLK PER 100' 0.0600 ROLL
59 JG-020800-W/MRT TGI-MALE RUN TEE 1/4ODX1/4ODX1/4NPT WHITE 1.0000 EA
60 JG-301208-W/3 FTG REDUCING BRANCH TE E3/8X3/8X1/4 IMPORT 1.0000 PC
61 JG-480822-W/3 TGI-PUSH IN FIXED ELBOW 1/4"TBX1/4,NPT WH 1.0000 PC
62 JG-481223-W/3 TGI-PUSH IN FIXED ELBOW 3/8"TB X 3/8,NPT WH 1.0000 PC
63 MH-200WL/3 TGI-MEMBRANE HOUSING WHITE SIDE PORT 1/8"NPT 3.0000 PC
64 MS1034 FTG MOUNTING SCREW #10X3/4" FOR 4000/4200 SERIES S 16.0000 EA
65 N-O-4W FTG JACO COMPRESSION NUT1/4" NUT/WHITE 6.0000 EA
66 NMSSS8C BOLT NUT HEX SS 8/32 12.0000 EA
67 PE-08-BI-0500FB TUB 1/4 INCH TUBE (500FTROLL) BLUE 0.0160 ROLL
68 PE-08-BI-0500FE TUB 1/4 Inch Tube (500ftRoll)BLACK 0.0180 ROLL
69 PE-08-BI-0500FG TUB 1/4 Inch Tube (500ftRoll)GREEN 0.0040 ROLL
70 PE-12-EI-0500FN TUB 3/8 Inch Tube (500ftRoll)NATURAL 0.0020 ROLL
71 PIC1808R FTG 1/4 LOCKING CLIP RED 46.0000 EA
72 PIC1812R FTG 3/8 LOCKING CLIPRED 5.0000 EA
73 PP301208W FTG 3/8 - 1/4 - 3/8 REDUCING BRANC WHITE 1.0000 EA
74 PPC-1000 PART PERMEATE PUMP CLIPFOR ERP1000 3.0000 EA
75 Q5721 CAR - Q SERIES REPLACEMENT FILTER 2 1/2" X 14"/10U 4.0000 EA
76 R191434-SS BOLT NC HEX CAP SCREW .25"NCX.75" 18-8SS 6.0000 EA
77 R1914F-SS BOLT WASHER FLAT .25" 18-8SS 10.0000 EA
78 R1914SN-SS BOLT NUT LOCK NYLON INSERT .25"NC 18-8SS 8.0000 EA
79 R19832SN-SS BOLT NUT LOCK NYLON INSERT 8-32 18-8SS 12.0000 EA
80 WA-ME0402 ELBOW MALE 1/4"TUBE X 1/8 9.0000 EA
Customer Service Toll Free Hot Line: 888-774-7405 1725 W. Williams Dr. C-20 Phoenix, AZ 85027
HS-200 Quarterly PM Maintenance Procedure:
Remove Front Panel Figure 1
Remove 3 prefilters
Figure 2
Remove Calcite feeder
Figure 3
1. Remove eight screws from front panel (figure 1). Remove front panel, 2. Unscrew first stage sediment filter by grasping and turning counter clockwise (Figure 2) (No need to turn off incoming water source) discard, unscrew remaining filters and discard. 3. Install new filters by removing yellow cap (figure 3).on top and inserting each
filter into corresponding element head. Insure all filters are hand tight and listen for permeate pumps to begin pulsating, check for leaks
4. Secure front panel. A full one-year supply of filters is supplied with system upon installation. After one year of service the HS-200 will need to have an annual PM kit ordered #61301605518 this kit will include one full year supply of pre-filters and three replacement membranes.
Customer Service Toll Free Hot Line: 888-774-7405 1725 W. Williams Dr. C-20 Phoenix, AZ 85027
Membrane replacement: Performed every year after the first year in service. Annual PM Procedures: Follow quarterly PM procedures as described above.
1. Remove top and front panels 2. Remove 3 prefilters and post calcite feeders (DO NOT REPALACE WITH
NEW FILTERS AT THIS TIME) 3. Remove 3 Reverse Osmosis Membranes (figure 5) 4. Replace with new membranes provided in PM kit #501020 5. Replace 3 prefilters and PH Balancer. Installing these filters will turn the water
supply on to the unit and start production of water.
Figure 4 Figure 5 Figure 6 Remove eight screws from front panel. Remove front panel. Remove first stage filter to shut down incoming water flow to system. Drain the tank of boiler feed water by performing a blow down on the boiler. After tank has been completely drained, disconnect the membranes by pressing in on the collets around the colored tubing (figure 6) to the membrane and pull. Each membrane should be removed one at a time insuring proper placement of tubing in corresponding color coded ports. Re-tighten first stage filter to start water flow, listen for permeate pumps to begin pulsating and check for leaks then secure panel. By passing the unit: The HS-200 unit can be placed into by pass if for some reason the equipment has failed and or has clogged filters. To by pass the RO system, open top panel by removing eight screws (figure 7)and open ½” brass “Watts” ball valve (figure 8) for tap water by-pass. After service has been achieved close the “Watts” ball valve and wait for the system to begin permeating.
Figure 7 Figure 8
Series 1170, L1170 Hot Water Temperature Control Valves Size: 1h'\ %11
, 111 (15, 20, 25mm)
Installation Instructions Valve should be installed and adjusted by a licensed contractor in accordance with local codes and ordinances. Further, this valve should be Installed in a location where it is accessible for cleaning, service or adjustment.
1 . Close both the hot and cold water shutoff valves upstream nearest to the intended installation.
2. Bleed the remaining water from the system.
3. Connect the water supply to valve as shown in Flgure 1 or 2, depending on the application. Supply piping must be flushed clean before making connections to the valve.
IMPORTANT!: To prolong the life of the Model 1170-M2, L1170-M2 valve, it is recommended that it be trapped as shown: I.e. t11e hot water inlet to the 1170-M2 valve should be 8" - 12" (200 - 305mm) below the hot water supply feed.
4. Valve can be installed in any position. Note: the inlet hot supply is to be connected to the "H" side of the valve, the cold supply side to the "C" side and the mixed water outlet to the "M" side. ·
~ 5. Make sure union nuts are placed over tailpieces prior to
IS-1170-M2_L 1170-M2
1170-UT-M2
(
1170-QC-M2
'~ soldering or threading to pipe.
6. For valves with Quick-Connect tailpieces refer to "QuickConnect Installation" instructions below.
Quick-Connect Installation
Note: To prevent damage to valve from excessive heat during soldering, remove unions and gaskets from valve body prior to
~ soldering .
7. After soldering, flush piping and install valve using filter washer on hot and cold water inlet and fiber washer on the mixed water outlet.
8. Start-up: Open cold water supply, then hot water supply. Inspect for leaks.
9. Adjust temperature to desired setting (see Temperature Adjustment Section).
Figure 1
Domestic Hot Water Application
WattsT&P Relief Valve
i +u !!! (I)
a. E ~
·a·-12·
I 1170-M2, L 1170·M2
u_~::::::::~-Cold
Domestic Hot Water Application
Note: To prolong the life of the valve, it is recommended the valve be trapped as shown
Devices tested !o ASSE Standard 1016 such as Watts USG, L 111 or MMV should be used at fixture to prevent possible injury.
To Connect
11/: In. {JB.lmm) -- -:-t '" ln.Plpop2.7mm)
1'1• In. (44.45mm)
· 'ld :1 Pojl!! (19.0511111J)
1'/1 In. (47.63mm)
1 In.Pipe {25.4mm)
1. Mark ~ipe as shown. • This is pipe insertion depth.
PEX tubing only
3. If using PEX tubing, insert pipe s1Kfener (proyided) into end of pipe.
lo Disconnect
/ /
2. Clean pipe end.
~ /Collolcllp
---- ', -I
.. t Mark
4. Push tubing into !&piece up to mark. 5. Insert collet clip.
l - -
\ Colle! depll?SS!Hf
1. Remove collet clip. 2. Depress collet. 3. Pull tubing from tailpiece.
WWMI IS®
Figure 2
Radiant Heat Application
i. to Boiler
Figure 3
Temperature Adjustment
Factory Preset: 1·~. 170-M2: 120°F (49°C) L 1170-M2: 90°F (31°C)
Un.der following conditions:
Cold Inlet: 60-70°F (16-21°C) Hot Inlet: 140-145°F (60-63°C) $upply Pressure: 45psi (3.15 bar)
B-6000 o 11.' Ball Valve ""\'f..e oie.~
,,....,., \0 \'.\'Ci
~ Unscrew, lift cap to adjust
3/32" Hex Wrench
1 . Let water flow for at least two minutes to allow supply temperature to stabilize.
2. Calibrate the mixed water outlet temperature by placing a thermometer in the mixed water stream.
3. To adjust the setting of the valve, loosen locking cap screw with hex wrench, see Figure 3. Cap must be lifted 1/4" to adjust temperature. To increase the temperature, turn counterclockwise. To decrease temperature turn clockwise.
4. Lower handle and tighten screw.
5. Check outlet temperature.
Period Inspection/Maintenance Tl1is valve requires periodic inspection and verification of the outlet temperature by a licensed contractor. Corrosive water conditions, hot inlet water temperature over 200°F (93°C), unauthorized adjustments or repairs could render the valve ineffective for its intended service. Regular cleaning and checking of thermostat assembly helps to maximize valve life and mixing function. Frequency of cleaning depends on local water conditions.
Pressure - Temperature Minimum Supply Pressure (Static): 30psi (207 kPa)
Inlet Temperatures: hot inlet, 120°F - 200°F (49°C - 93°C), cold inlet, 40°F - B5°F (4°C - 29°C)
Hot Water Inlet to Outlet Differential Temperatwe: 5°F (3°C)
1170-M2 Temperature Out: Field range: 90°F - 160°F (32°C - 71 °C), adjustable. Accurate within ±3°F (1 .7°C)
L 1170-M2 Temperature Out: Field range: 60°F - 120°F (16°C - 49°C), adjustable. Accurate within ±3°F (1.7°C)
Maximum Temperature: 200°F (93°C)
Maximum Pressure: 150psi (10.3 bar)._ .
Approval: CSA 8125 certified Listing: ASSE 1017
l
,,
tWARNlNG Watts Hot Water Temperature Control Valves cannot be used for tempering water tempera~e at fixtures. Severe bodily injury O.e. scalding or chilling) and/or dej;th may result depending upon system water pressure changes. ASSE Standard 1016, ASSE 1070 listed devices such as Watts Model L 111 or Series USG, or MMV should be used at fixtures to prevent possible injury. The Watts Hot Water Temperature Control Valves are designed to be inslalled at or near the boiler or water heater. They are not designed to compensate for system pressure fluctuations and should not be used where ASSE 1016 devices are required. These WATIS valves should never be used to provide "anti-scald" or 'anti-chill" service.
When installing the Series 1170-M2 valves in a radiant heat ilpplicatlon, the components of the radiant heat system must be of materials with a construction capable of wilhstanding the high fimlt output temperatures of the heating boiler. If you are uncertain as to the product's adaptability for your application, please consult an authorized representative before installing or using the product.
I·
" <
r'
Watts 1170-M2, L 1170-M2 Troubleshooting Guide Problem & Cause
~· Unaqle tp reach required sel point or set polnl difficult to set
A.1 Supply temperatures not within specified llmit!;
A? Hot and cold supplies reversed
A.3 Filters are blocked by pebris
8. Unable to achieve required flow
8.1 Too much pressure drop at fixture
8.2 Checks valve/filters blocked by debris
C. Valve does not maintain required temperature or temperature changes over time
c.1 Fluctuation in supplx pressures
C.2 Check valve/fillers bl~cked by debris
C.3 Recirculation loop not piped properly
·:o. Discharge temperature loo hot or cold
0.1 Valve not calibrated properly
~· Hot water from cold water tap or cold from hot
' E.1 Check valves fouled
F. Valve is noisy F.1 Water velocity is too high
F.2 Valve not sized properly
~· No flow from valve
G.1 Hot or cold water supply failure or shutoffs closed
G.2 Check valve/filters block~d by debris
H. Flow from valve fluctuates
H.1 Fluctuation in supply pressures
H.2 Check valve/filters blocked by debris
Answer
A.1 Check di_fferential •temper(!ture betwe_en hpt and cold supplies and outlet 10°F (5.6°C) minimum required
A.2 Reinstall valve with supplies connected to marked inlets
A.:,3 Clean filters
8.1 Measure supply pressures and check against flow chart. Look for restrictions in valve or piping-
8.2 Clean check valves/filters
C.1 Stabilize water pressures with·pressure re!;Julatlng·or balancing valves
C.2 Clean check valves/fili-ers
C.3 .Pipe recirculated tempered water return so ii connects
to hot water so~irce and cold side of mixing valve
(see Product Guide for piping details)
- . ·-- . · : 1!
0.1 Readjust valve temperature per installation instruclions
E.1 Clean check valves/filters
r F.1 Reduce water velocity wilt) i;iressure regulating valves
F.2 Check flow required versus rated flow capacity of valve ,
G.1 Open shutoffs or restore hot and cold supply
G.2 Clean check valves and filters
H.1 Stabilize water pressure with pressure regufating valves
H.2 Clean check valves and filters
ATTENTION INSTALLER: After installation, please leave this Instruction Sheet for occupant's information. IMPORTANT: Inquire with governing authorities for local installation requirements.
WARNING! For valves with CPVC or PEX end connections do not exceed the tubing manufacturers pressure and temperature ratinps. Refer to the tubing manufacturers product specifications for that information.
I
r I
CALIFORNIA PROPOSITION 65 WARNING WARNING: This product contains chemicals known to the State of California to cause cancer and birth defects or other reproductive harm. (California law requires this warning to be given to customers In the State of California.) For more inlonnalion: www.watts.com/prop65
Umited Warranty: Watts Regulator Company warrants each product to be free from defects in material and workmanship under normal usage for a period of one year from the date of orl,~al shipment In the event of such defects wilhin the warranty period, Uie Company will, at Its option, replace or recondition tile product witllout charge. This shall constitute the solo and exclusive remedy for breach of warranty, and Uie Company shall not be responsible for any incidental, special or consequential damages, Including without llmltatlon, lost profits or the cost of repairing or replacing other property which Is damaged If this product does not work properly, othor costs resulling from labor charges, delays, vandalism, negligence, fou ling caused by foreign materlal, damage from adverse water conditions, chemical, or any other circumstances over which the Company has no control. This warranty shall be invalidated by any abuse, misuse, misapplication or Improper installation of the product THIS WARRANTY IS IN LIEU OF All OTHER WARRANTIES, EXPRESS OR IMPLIED, fNCWDING ANY IMPLIED WARRAHTJES OF MERCHANTABILITY OR ATNESS FOR A PARTICULAR PURPOSE. Any lmpOed warranties that are imposed by law are 6mlled In duration to one year. Some States do not allow limitations on how long an implied warranty lasts, and some States do not allow tile exclusion or limitation or Incidental or consequential damages. Therefore the above limitations may not apply to you. TI1ls limited Warranty gives you specific legal rights, and you may have otlrnr rights that vary from State to State. You should consult applicable state laws to determine your rights.
WWMI IS® Water Safety & Flow Control Products
IS-1170-M2_L 1170-M2 0735
• 9001 CETmFIED
USA: Bl 5 Chestnut St., No. Andover, MA 01845-6098: www.watts.com
Canada: 5435 North Service Rd., Burlington, ONT. L7L 5H7; www.wattscanada.ca
EDP/I 1915905 ©Watts Regulator Co., 2007