Sensor-Actuator-Interface-Active

Page 4: Weidmuller SAI PI

Overview

4

SAI-Active Universal

I/O LEDs for status, input and output

as well as individual channel diagnosis

Status LEDs for voltage,

fieldbus and

group diagnosis

2 x Multicard markers or

1 x 40-mm long strip

for printing IP addresses

2-hole mounting and functional earth connection

Transparent strips of markers:

• A marker for each I/O point

• Illuminated print

• Printjet compatible

M12 or M8 circular connectors

with threaded ring made of metal

Illuminated configuration area

for fieldbus address and

plug-in jumpers for voltages

2 x M12 circular connectors for fieldbusses

2 x M12 circular connectors for power supply

Just 54 mm wide

The SAI-Active Universal range is the result of years of

experience that Weidmüller has made with distributors for

industry. The fieldbus systems supported are PROFIBUS-DP,

DeviceNet™ and CANopen.

The housing has been tailor made to meet the demands of

industry. That is why it is resistant to aggressive cleaning

agents, vibration, shocks and temperature as well as being

sealed against the ingress of water and dust.

One module – three Ethernet dialects

The new SAI Active Universal modules for Industrial Ethernet

have three Ethernet dialects integrated. The module selects

PROFINET IO, EtherNet/IP or Modbus TCP by means of

automatic port recognition functionality.

Page 5: Weidmuller SAI PI

5

Overview

Connection technology

The concept behind the new distributors champions rapid and

simple installation in harsh environments. Commercially avail-

able, standardised M8 and M12 connectors form the back-

bone of the connection technology. Robust threaded rings

made of metal as well as standard assignments ensure safety

and fewer mistakes during the wiring process.

Two M12 connections are available respectively for the field-

bus. Thus, there is no need for an external T-piece – and the

modules can easily be connected up to one another. As the

standards specify, B-coding is used for PROFIBUS-DP and

A-coding for DeviceNet™ und CANopen. Industrial Ethernet is

wired point-to-point from a switch. The modules are equipped

with a D-coded M12 connector.

User-friendly connection of the functional earth is achieved by

means of a metal clip in the mounting hole. A secure contact is

created automatically when screwed to an earthed base made

of metal. Otherwise, the screw point offers sufficient space for

a round cable lug, via which a cable can be connected for

dissipation purposes.

Two central mounting holes ensure simple and reliable

mounting.

Status indication

I/O statuses are indicated by means of elegant light guides

in the form of arrowheads. These point in the direction of

the markings and connectors.

The light also illuminates the corresponding marker, which

allows it to be quickly and clearly read under working

conditions.

In addition, the power supplies, group diagnostic messages

and fieldbus statuses are indicated via seven status

indicators.

Page 6: Weidmuller SAI PI

Overview

6

SAI-Active Universal

The electronics

Diagnosis

Each I/O channel is constantly scanned for errors. If an error is

detected, the colour of the LED changes from yellow to red

and a message is transmitted via the fieldbus. As well as

individual channel diagnostics, a module diagnosis is also

available for overvoltages, short-circuits and the fieldbus.

Outputs

The outputs are short-circuit proof as well as being protected

against polarity reversal. Two outputs are available for high-

performance actuators that can be operated with max. output

power of 2 A. As well as offering freedom of choice between

16DI through to 8DI/8DO, the 16DI/8DO allows the user to

customise the configuration to suit the application.

Analogue modules

The analogue combi-module is uniquely versatile. The configu-

ration between current and voltage is selected via the configu-

ration software of the master. JACKPAC® offers further inter-

face options. These modules are simply installed between the

distributors and the sensors where they condition signals.

The module offers 4 additional digital inputs.

Power supply

The modules can be supplied with max. 4 different voltages.

In addition to the module voltage, which is also used for the

inputs, three supply terminals are available for the outputs.

The outputs can also be individually switched off in accordance

with application needs. Two jumpers provide the option of

bridging the electrical power supply. Thus enabling 3 output

circuits to be operated separately.

Illuminated configuration area

The configuration area for the module is situated below the

transparent cover. Two rotary switches are available to set the

fieldbus addresses. Thus allowing up to a max. 126 addres-

ses to be set for PROFIBUS-DP. Two jumpers have also been

included on the right-hand side to bridge the electrical power

supplies. Illuminating the configuration area is to date a unique

feature that signalises the module is switched on and

functioning. Moreover, it also allows the rotary switches to be

more easily recognised.

Page 7: Weidmuller SAI PI

Overview

7

Transparent markers

A marker is available for each I/O channel as well as two

markers for the module as a whole. The markers do not have

to be fitted individually on the I/O side. Marker strips offer the

added advantage of rapid installation. An additional 40-mm

wide marker has been specially adapted to suit the module.

This allows longer texts such as markings with up to

40 characters to be fitted and clearly read without hindrance.

Supplementary products

A Multicard strip is included in the range of supply for marking

the module. In conjunction with Weidmüller’s PrintJet, these

markers are remarkably user-friendly to print.

The new M12 sealing plugs can now be more easily fitted

manually and to the correct torque using our Screwty® tool.

Two additionally integrated slots allow the plug to be fitted with

either a small or large flat bladed screwdriver.

Cables and accessories provide a perfect finish to our

programme of distributors.

Page 8: Weidmuller SAI PI

Applications

8

SAI products in action

If it is true that Weidmüller belongs to the world-wide leaders

in the field of distributors, then this has a particularly good

reason. In developing SAI distributors Weidmüller’s design

engineers have concentrated on achieving economically

favourable installation concepts. This has led, quite often in

close co-operation with renowned users, to the introduction of

sophisticated products onto the market that lead the way with

regard to functionality and set standards in quality – all over

the world.

Today, modern installation concepts have to be drawn up so

that they save materials, money, time, space and weight from

the very beginning. For that reason, products that make such

concepts possible are of crucial significance.

And it is exactly in this regard that you can trust Weidmüller's

quality, experience and innovative force.

Page 9: Weidmuller SAI PI

Applications

9

‘Mounted directly’, Weidmüller’s SAI distributors are integrated

into the machine or system. They bring together signals from

the sensors and actuators on the spot. At this point, installa-

tion and service costs can be reduced by utilising pre-

assembled cables and commercially available M8/M12 circular

connectors. Fieldbus interfaces on the other side of the

distributor provide the connection to the controls.

In order to supply the customer with optimum products for

their applications, the new SAI-Active Universal series has

turned to innovative ideas and remained true to proven

standards. Our SAI-Active distributors are at home in factory

automation - in the field. Exactly where the process is in action

– where the sensors and actuators are fitted. These versatile

products support all conventional fieldbus systems as well as

being able to process both analogue and digital signals.

Page 10: Weidmuller SAI PI

10

System description PROFIBUS-DP

PROFIBUS

Principle

PROFIBUS-DP is a master–slave system consisting of one

master (usually implemented in the PLC) and up to 31 slaves

per segment. During operation, the master constantly interrog-

ates the slave stations. Several masters can also be integrated

within one network to relay the transmission authorisation

(token passing).

PROFIBUS-DP uses a physical layer based on the RS 485

standard which has performed excellently in industrial applica-

tions.

The system uses a shielded, twisted 2-wire cable and is

extremely resistant to electrical interference. PROFIBUS-DP

is suitable for connecting a large number of I/O points. Up

to 126 addressable subscribers enable the connection of

thousands of analogue and digital I/O points within a network.

Every PROFIBUS-DP module has a so-called GSD file which

contains detailed information about the module (I/O data

volume, possible transmission rates, update status, etc.).

The station GSD file is required in order to configure a station

within the PROFIBUS-DP system.

The GSD files are available on the Weidmüller website at

www.weidmueller.com.

Network structure

The network is constructed as a line structure with an active

bus termination at both ends.

When utilising SAI-Active Universal modules a bus terminator

plug (Order No.: 1784770000) is plugged into the BUS-Out

socket. Ideally, no spur lines should be created; to that end,

the Weidmüller modules have been designed with two

connections for connecting the fieldbus.

Max. 126 nodes can be addressed at all transmission

rates. The maximum extension with 7 repeaters is 9.6 km

(8 x 1.2 km).

Bus extension

Transmission Length of bus line Stub cable length No. of repeaters

rate Total segment (max.)

9.6 kbps 1200 m 6.6 m 7

19.2 kbps 1200 m 6.6 m 7

93.75 kbps 1200 m 6.6 m 7

187.5 kbps 1200 m 6.6 m 7

500 kbps 400 m 6.6 m 7

1.5 Mbps 200 m 6.6 m 4

12 Mbps 100 m preferably none 4

Maximum system extension

PROFIBUS-DP can accommodate max. 32 devices per

segment. One segment corresponds to a subsection between

two repeaters. If no repeaters are used, the complete network

corresponds to one segment. The following table indicates

the maximum extension options.

Addressing

The address setting for the corresponding station is set

manually by means of two coded rotary switches.

Transmission rate

The transmission rate must be identical throughout the

whole network, and is defined by the master. The baud rate

is compared automatically upon switching on. No adjustments

need to be made at the module.

At 12 Mbps the typical response time is < 1 ms per

1000 I/O points.

The baud rate cannot be changed during operation!

Page 11: Weidmuller SAI PI

11

PROFIBUS

PROFIBUS-DP Universal

Ordering dataPlug-on type

16 digital inputs

16 digital inputs / 8 digital outputs

4 analogue inputs / 2 analogue outputs / 4 digital inputs

Information

Technical data bus system

Bus sharing unit Slave

Transmission rate Max. 12 Mbps

Diagnostic display red

Fieldbus interface RS 485

Potential isolation yes

Station address rotary switch 1–125

bps rate automatic

Information

Technical dataGeneral data

Insulation material of housing PBT

Flammability class UL 94 V-0

Operation temperature 0 °C ... 55 °C

Storage temperature –25 °C ... 70 °C

Ingress protection class IP 67

Electrical data electronics-module

Operating voltage 24 V DC (20,4 … 28.8 V)

Max. current carrying capacity per output signal 0.5 A; 2.0 A

Output levels Short-circuit-protected

Total current. max. 8 A

Digital inputs TYPE 1 to EN 61131-2

Analogue outputs –10 … +10 V; 0 … +10 V; 0 … 20 mA; 4 … 20 mA

Analogue inputs –10 … +10 V; 0 … +10 V; 0 … 20 mA; 4 … 20 mA

Resolution 12 Bit

Accuracy < 0.2 %

UL certification in preparation UL certification in preparation

Type Qty. Order No.

SAI-AU M8 PB 16DI 1 1906550000

SAI-AU M8 PB 16DI/8DO 1 1906640000

Type Qty. Order No.

SAI-AU M12 PB 16DI 1 1890020000

SAI-AU M12 PB 16DI/8DO 1 1890010000

SAI-AU M12 PB AI/AO/DI 1 1890000000

AccessoriesPlug Type Qty. Order No.

Terminating plug PB in M12 plug SAIEND PB M12 5P B-COD 1 1784770000

Metal plug, pin M12, 5-pole, b-coded SAISM 5/8S M12 5P B-COD 1 1784790000

Metal plug, socket M12, 5-pole, b-coded SAIBM 5/8S M12 5P B-COD 1 1784780000

Accessories

Protective cap, M12, black SAI-SK-M12-UNI 20 2330260000

Marker, transparent ESG 8/13.5/43.3 SAI AU 5 1912130000

SAI-AU SAI-AU

M8 M12

Page 12: Weidmuller SAI PI

12

DeviceNetTM

DeviceNetTM

Principle

DeviceNetTM is a fieldbus system from the USA that is being

increasingly employed in Europe and Asia. In terms of the

physical layers 1 and 2 of the ISO 7-layer model, DeviceNetTM

is based on CAN (Controller Area Network).

The ISO application layer (layer 7) in DeviceNetTM makes use

of the so-called “Common Industrial Protocol” (CIP). This is

an open standard which is also used for ControlNetTM and

EtherNet/IP. In the future this will enable permanent communi-

cation between the field level and the Internet.

DeviceNetTM is a multi-master system and its protocol pri-

oritises the data traffic in such a way that I/O signals have

a higher priority than configuration data.

Every DeviceNetTM module has a so-called EDS file (Electronic

Data Sheet), containing an exact description of the module.

All information about I/O and status data required by a master,

e.g. a PLC or IPC, are saved in this file and can be used to

integrate the module step by step into the control program.

The EDS files are available for downloading on the Weidmüller

website at www.weidmueller.com.

Network structure

ISO 11898 prescribes a line structure for the DeviceNetTM

network.

A line structure has a terminating resistor of 120 Ω at each

end. A bus terminator connector (order No. 1784760000) can

be plugged into the “Bus OUT” output socket of the

Weidmüller DeviceNetTM SAI distributors.

Ideally, there should be no stub cables; Weidmüller modules

have two special connections for the fieldbus. The number of

subscribers is limited to 63.

Addressing

Any address from 1 to 63 is possible. The address setting of

the station can be set manually at the device or via the master.

Two coded rotary switches are located underneath the cap,

with separate adjustment of tens and units.

Bus line length, transmission rate

The maximum length of the bus line depends on the transmis-

sion rate (baud rate). The following table serves as a guide for

an optimum bus design:

Max. bus expansion in m Data rate in kbps

500 125

250 250

100 500

DeviceNet™

Pin Plug (x71) Socket (x72)

1 shield

2 Vplus

3 CAN-GND

4 CAN-H

5 CAN-L

Housing shield

Page 13: Weidmuller SAI PI

13

DeviceNetTM

DeviceNetTM Universal

Ordering dataPlug-on type

16 digital inputs

16 digital inputs / 8 digital outputs

4 analogue inputs / 2 analogue outputs / 4 digital inputs

Information

Technical data bus system

Bus sharing unit Slave

Transmission rate Max. 500 kbps

Diagnostic display red

Fieldbus interface RS 485

Potential isolation yes

Station address rotary switch 1–63

bps rate automatic

Information

Technical dataGeneral data

Insulation material of housing PBT

Flammability class UL 94 V-0

Operation temperature 0 °C ... 55 °C

Storage temperature –25 °C ... 70 °C

Ingress protection class IP 67

Electrical data electronics-module

Operating voltage 24 V DC (20.4 … 28.8 V)

Max. current carrying capacity per output signal 0.5 A; 2.0 A

Output levels Short-circuit-protected

Total current. max. 8 A

Digital inputs TYPE 1 to EN 61131-2

Analogue outputs –10 … +10 V; 0 … +10 V; 0 … 20 mA; 4 … 20 mA

Analogue inputs –10 … +10 V; 0 … +10 V; 0 … 20 mA; 4 … 20 mA

Resolution 12 Bit

Accuracy < 0.2 %

UL certification in preparation UL certification in preparation

Type Qty. Order No.

SAI-AU M8 DN 16DI 1 1906730000

SAI-AU M8 DN 16DI/8DO 1 1906740000

Type Qty. Order No.

SAI-AU M12 DN 16DI 1 1906700000

SAI-AU M12 DN 16DI/8DO 1 1906710000

SAI-AU M12 DN AI/AO/DI 1 1906720000

AccessoriesPlug Type Qty. Order No.

Terminating resistor in M12 plug SAIEND CAN-M12 5P A-COD 1 1784760000

Metal plug, pin M12, 5-pole, A-coded shield SAIS-M-5/8S M12 5P A-COD 1 1784740000

Metal plug, socket M12, 5-pole, A-coded shield SAIB-M-5/8S M12 5P A-COD 1 1784750000

Accessories

Protective cap, M12, black SAI-SK-M12-UNI 20 2330260000

Marker, transparent ESG 8/13.5/43.3 SAI AU 5 1912130000

SAI-AU SAI-AU

M8 M12

Page 14: Weidmuller SAI PI

Bus line length, transmission rate

The maximum length of the bus line

depends on the transmission rate (baud

rate). The following table serves as a

guide for an optimum bus design:

14

The CANopen system

CANopen

CANopen (M12 A-coded)

Pin Plug (x71) Socket (x72)

1 shield

2 not used

3 CAN-GND

4 CAN-H

5 CAN-L

Housing shield

Active

A CAN network is based on a server–

client principle with a serial bus connec-

ting network subscribers having equal

access status. The electrical connection

consists of a 2-wire line with or without

shielding depending on the application.

CANopen was defined as a uniform

protocol for networking the different

CANopen subscribers. The protocol

stipulates the significance of the data

for the corresponding device type (e.g.

I/O modules, drives, shaft encoders,

controls).

This means it is now easy for application

programmers to use all types of

CANopen-compatible components

irrespective of manufacturer.

CANopen subscribers in the same devi-

ce series organise their data in the same

way. The characteristics of these device

classes are summarised in “device

profiles”.

An object directory is defined in

CANopen nodes and describes all devi-

ce parameters. This is used not only for

device description but also as a data

access interface by other CANopen

devices.

Larger, non-time-critical data quantities

are transmitted using “service data

objects” (SDO). In addition, at least

two “process data objects” (PDO) are

available for transmitting process data.

Manufacturer-specific objects and other

functions are described in the manual.

Every CANopen module has a so-called

EDS file (Electronic Data Sheet) contai-

ning an exact description of the module.

All information about I/O and status data

required by a master, e.g. a PLC or IPC,

Bus expansion

Max. bus expansion Data rate in kbps

7000 m 10

3500 m 20

600 m 125

300 m 250

90 m 500

40 m 1000

are saved in this file and can be used

to integrate the module step by step into

the control program.

The EDS files are available for down-

loading on the Weidmüller website at

www.weidmueller.com.

Network structure

ISO 11898 prescribes a line structure for

the CANopen network. A line structure

has a terminating resistor of 120 at each

end.

The cable gland version of the

Weidmüller CANopen SAI distributors

have an internal switch for activating the

terminating resistor.

When utilising SAI-Active Universal

modules a bus terminator plug (Order

No.: 1784760000) is plugged into the

BUS-Out socket. Ideally, no spur lines

should be created; to that end, the

Weidmüller modules have been designed

with two connections for connecting the

fieldbus.

Addressing

Any address from 1 to 126 is possible

with CANopen. The address is set by

means of two coded rotary switches in

the module.

Page 15: Weidmuller SAI PI

15

CANopen

CANopen Universal

Ordering dataPlug-on type

16 digital inputs

16 digital inputs / 8 digital outputs

4 analogue inputs / 2 analogue outputs / 4 digital inputs

Information

Technical data bus system

Bus sharing unit Slave

Transmission rate Max. 1 Mbps

Diagnostic display red

Fieldbus interface RS 485

Potential isolation yes

Station address rotary switch 1–125

bps rate automatic

Information

Technical dataGeneral data

Insulation material of housing PBT

Flammability class UL 94 V-0

Operation temperature 0 °C ... 55 °C

Storage temperature –25 °C ... 70 °C

Ingress protection class IP 67

Electrical data electronics-module

Operating voltage 24 V DC (20.4 … 28.8 V)

Max. current carrying capacity per output signal 0.5 A; 2.0 A

Output levels Short-circuit-protected

Total current. max. 8 A

Digital inputs TYPE 1 to EN 61131-2

Analogue outputs –10 … +10 V; 0 … +10 V; 0 … 20 mA; 4 … 20 mA

Analogue inputs –10 … +10 V; 0 … +10 V; 0 … 20 mA; 4 … 20 mA

Resolution 12 Bit

Accuracy < 0.2 %

UL certification in preparation UL certification in preparation

Type Qty. Order No.

SAI-AU M8 CAN 16DI 1 1906680000

SAI-AU M8 CAN 16DI/8DO 1 1906690000

Type Qty. Order No.

SAI-AU M12 CAN 16DI 1 1906650000

SAI-AU M12 CAN 16DI/8DO 1 1906660000

SAI-AU M12 CAN AI/AO/DI 1 1906670000

AccessoriesPlug Type Qty. Order No.

Terminating resistor in M12 plug SAIEND CAN-M12 5P A-COD 1 1784760000

Metal plug, pin M12, 5-pole, A-coded shield SAIS-M-5/8S M12 5P A-COD 1 1784740000

Metal plug, socket M12, 5-pole, A-coded shield SAIB-M-5/8S M12 5P A-COD 1 1784750000

Accessories

Protective cap, M12, black SAI-SK-M12-UNI 20 2330260000

Marker, transparent ESG 8/13.5/43.3 SAI AU 5 1912130000

SAI-AU SAI-AU

M8 M12

Page 16: Weidmuller SAI PI

16

PROFINET

PROFINET

Principle

PROFINET is the open automation standard of the PROFIBUS

Users Organisation. The aim is to realise a consistent auto-

mation concept based on Industrial Ethernet that is indepen-

dent of manufacturers.

The PROFINET specification distinguishes between three dif-

ferent forms:

• PROFINET CBA (component-based automation) a superim-

posed networking of installation elements

• PROFINET IO for real-time communication with field devices

• PROFINET IRT for isochronous real-time communication,

e.g. with drives

The Weidmüller SAI modules comply with the PROFINET IO

standard and are approved by the PROFIBUS Users

Organisation. The customary IO view familiar to PROFIBUS-DP

users is employed, with cyclic transmission of the IO data of

field devices to the process image of the PLC.

PROFINET IO describes a device model that is based on the

key features of PROFIBUS-DP and comprises slots and chan-

nels. The characteristics of the field devices are described by

a GSD (General Station Description) on an XML basis.

Network structure

PROFINET installations are based on the specific requirements

for Ethernet networks in an industrial environment. They pro-

vide the device manufacturer with clear specifications for

device interfaces and the cabling required.

Like Standard Ethernet, PROFINET installations are also wired

with a star structure. The star structure is characterised by a

central signal distributor (switch) with individual connections

to all the network’s terminals. A line or tree structure can be

set up with the help of a 3-port switch in the device or in the

proximity of each device.

Weidmüller can supply products for the network infrastructure

– please refer to our Industrial Ethernet catalogue.

Addressing

Address assignment supports two standards:

Discovery and Basic Configuration protocol (DCP) and

Dynamic Host Configuration Protocol (DHCP).

• DCP enables assignment of IP parameters with manufac-

turer-specific configuration/programming tools or in pan-

system engineering.

• DHCP specifies the Ethernet standard for dynamic assign-

ment and management of IP addresses from a predefined

range.

Transmission rate

The transmission rate is 10 or 100 Mbps.

Weidmüller modules detect the transmission rate automatically

and set themselves accordingly.

PROFINET distinguishes between three categories for the

transmission of data:

• TCP, UDC and IP for non-time-critical data such as par-

ameter assignment and configuration; response time 100 ms

• Soft Real Time (SRT) for time-critical process data used in

factory automation; response time 10 ms

• Isochronous Real Time (IRT) for particularly demanding

applications, e.g. motion control; response time < 1 ms

category.

The maximum length of the bus cable is the same for both

transmission rates.

The following table can serve as a guide for bus installations

complying with the standard:

Max. bus extension (m) Data rate (Mbps)

100 10

100 100

Page 17: Weidmuller SAI PI

17

EtherNet/IP

EtherNet/IP

Principle

EtherNet/IP (Ethernet Industrial Protocol) is an open standard

that was developed by Rockwell Automation and the Open

DeviceNet Vendor Association (ODVA) for industrial networks.

EtherNet/IP is based on the Ethernet TCP/IP standards and

the Common Industrial Protocol (CIP).

CIP an open standard that is implemented in ISO layer 7, and

is also used for ControlNet™ and DeviceNet™ installations.

This enables continuous communications between the field

level and the Internet. The protocol includes a control compo-

nent for cyclic, real-time-compatible I/O signal transmission

(implicit messaging) and an information component for the

configuration, diagnosis and management messages (explicit

messaging).

The I/O data uses the User Datagram Protocol/Internet

Protocol (UDP/IP) and the information data uses TCP/IP

protocols.

The IEEE802.3 standard is incremented on layers 1 and 2

(physical media and data link respectively).

Addressing

The Dynamic Host Configuration Protocol (DHCP) is used to

assign addresses to modules in EtherNet/IP networks.

Network structure

Like Standard Ethernet, EtherNet/IP installations are also wired

with a star structure. The star structure is characterised by a

central signal distributor (switch) with individual connections to

all the network’s terminals. A line or tree structure can be set

up with the help of a 3-port switch in the device or in the

proximity of each device.

Weidmüller can supply products for the network infrastructure

– please refer to our Industrial Ethernet catalogue.

Transmission rate

The transmission rate is 10 or 100 Mbps.

Weidmüller modules detect the transmission rate automatically

and set themselves accordingly.

The maximum length of the bus cable is the same for both

transmission rates.

The following table can serve as a guide for bus installations

complying with the standard:

Max. bus extension (m) Data rate (Mbps)

100 10

100 100

Page 18: Weidmuller SAI PI

18

Modbus TCP

MODBUS TCP

Principle

Modbus TCP is a fieldbus system for automation technology

based on EtherNet TCP/IP. It has been accepted by the

Internet Engineering Task Force (IETF) as a draft RFC standard

and has been made available for all to use by Schneider

Automation. Modbus TCP is based on Modbus, a well-

established industrial application protocol. The Modbus object

models remain unchanged.

A connection is set up via TCP/IP by the server (e.g. I/O

device) being addressed via port number 502. Commands are

initiated by the client (Master) and executed by the server

(slave). The length of a Modbus telegram is max. 256 bytes.

Network structure

Like Standard Ethernet, Modbus TCP installations are also

wired with a star structure. The star structure is characterized

by a central signal distributor (switch) with individual connec-

tions to all the network’s terminals. A line or tree structure can

be set up with the help of a 3-port switch in the device or in

the proximity of each device.

Weidmüller can supply products for the network infrastructure

– please refer to our Industrial Ethernet catalogue.

Addressing

The addressing is carried out via a BOOTP (Internet Bootstrap

Protocol) inquiry via the client, using the Dynamic Host

Configuration Protocol (DHCP), or the user can set the IP

address with a software tool.

Bus extension/transmission rate

The transmission rate is 10 or 100 Mbps.

Weidmüller modules detect the transmission rate automatically

and set themselves accordingly.

The maximum length of the bus cable is the same for both

transmission rates.

The following table can serve as a guide for bus installations

complying with the standard:

Max. bus extension (m) Data rate (Mbps)

100 10

100 100

Page 19: Weidmuller SAI PI

19

Active Universal

Active Universal

Ordering dataPlug-on type

16 digital inputs

16 digital inputs / 8 digital outputs

4 analogue inputs / 2 analogue outputs / 4 digital inputs

Information

Technical data bus system

Bus sharing unit Server

Transmission rate 10 / 100 Mbps

Diagnostic display red

Fieldbus interface IEEE 802.3

Potential isolation yes

Station address rotary switch 1-125

bps rate automatic

Information

Technical dataGeneral data

Insulation material of housing PBT

Flammability class UL 94 V-0

Operation temperature 0 °C ... 55 °C

Storage temperature -25 °C ... 70 °C

Ingress protection class IP 67

Electrical data electronics-module

Operating voltage 24 V DC (20,4…28.8 V)

Max. current carrying capacity per output signal 0.5 A;2.0 A

Output levels Short-circuit-protected

Total current. max. 8 A

Digital inputs TYPE 1 to EN 61131-2

Analogue outputs -10…+10 V;0…+10 V;0…20 mA;4…20 mA

Analogue inputs -10…+10 V;0…+10 V;0…20 mA;4…20 mA

Resolution 12 Bit

Accuracy < 0.2 %

Information UL certification in preparation

Voltage supply with standard M12 plug-in connectors (see chap. D)

Type Qty. Order No.

SAI-AU M8 IE 16DI 1 1906880000

SAI-AU M8 IE 16DI/8DO 1 1906890000

Type Qty. Order No.

SAI-AU M12 IE 16DI 1 1906850000

SAI-AU M12 IE 16DI/8DO 1 1906860000

SAI-AU M12 IE AI/AO/DI 1 1906870000

AccessoriesPlug Type Qty. Order No.

Metal plug Ethernet, socket M12, D-coded, straight SAISM-4/8S-M12-4P D-COD 1 1892120000

Metal plug Ethernet, pin M12, D-coded, straight SAIBM-4/8S-M12-4P D-COD 1 1892130000

Accessories

Protective cap, M12, black SAI-SK-M12-UNI 20 2330260000

Marker, transparent ESG 8/13.5/43.3 SAI AU 5 1912130000

SAI-AU SAI-AU

M8 M12

Page 20: Weidmuller SAI PI

20

Accessories

Profibus cables with moulded plugs

Dimensions

L L

M12

M12

M12

M12

The following cables are available:

Pre-assembled cables with a connector at one end only require

suitable plugs and sockets to complete the cable assembly.

Ordering dataMoulded plugs and sockets

one end only

straight plug 1.5 m

3.0 m

5.0 m

10.0 m

straight socket 1.5 m

3.0 m

5.0 m

10.0 m

Connecting cables

straight plug to straight socket 0.3 m

1.5 m

3.0 m

5.0 m

10.0 m

Note

Technical dataCable

Conductor cross-section mm2

Strands mm2

Insulation

Filler strand mm2

Individual shielding (wire)

Total shielding (cable)

Wire colour

Sheathing

Mechanical properties

Permissible temperature °C

Storage temperature °C

Operating temperature °C

Electrical properties

Impedance Ohm

Note

2 x 0.33

42 x 0.1

PE; 2.6 – 0.2 dia

0.34 stranded wire

aluminium foil

C-shielding made from tinned 0.1 mm wires,

coverage approx. 85 %

red, green

PUR, violet (RAL 4008)

–25 ... 80

–5 ... 80

135 – 165 at f = 3 – 20 MHz

L in the drawing is the cable length

Type (Qty = 1) Order No.

SAIL-M12G-PB-1.5U 1873300150

SAIL-M12G-PB-3.0U 1873300300

SAIL-M12G-PB-5.0U 1873300500

SAIL-M12G-PB-10U 1873301000

SAIL-M12BG-PB-1.5U 1873320150

SAIL-M12BG-PB-3.0U 1873320300

SAIL-M12BG-PB-5.0U 1873320500

SAIL-M12BG-PB-10U 1873321000

SAIL-M12G-M12G-PB-0.3U 1873310030

SAIL-M12G-M12G-PB-1.5U 1873310150

SAIL-M12G-M12G-PB-3.0U 1873310300

SAIL-M12G-M12G-PB-5.0U 1873310500

SAIL-M12G-M12G-PB-10U 1873311000

Other versions on request

Wall bushing

Ordering data

Type Length Qty Order No.

SAI-WDF-5P M12 60 mm 60 mm 1 1819450000

SAI-WDF-5PB M12 60 mm 60 mm 1 1820690000

SAI-WDF-4PB M12 60 mm 60 mm 1 1820700000

SAI-WDF-4P M12 60 mm 60 mm 1 1820710000

Page 21: Weidmuller SAI PI

21

Accessories

PROFIBUS-DP M12 plug-in connectors

Ordering dataPlug

4-pole, PG 7

4-pole, PG 9

5-pole, PG 9

5-pole, PG 9

8-pole, PG 9

Socket

4-pole, PG 7

4-pole, PG 9

5-pole, PG 9

5-pole, PG 9

8-pole, PG 9

Notes

Technical data

No. of Poles

Type of connection

Housing material

Connection thread

Cable connection diameter mm

Connection cross-section mm2

Rated current A

Rated voltage V

Temperature range °C

Class of protection

Contact surface

Notes

Plug / socket

5-pole straight

Type Qty Order No.

SAISM-5/8S M12 5P B-COD 1 1784790000

SAIBM-5/8S M12 5P B-COD 1 1784780000

Other versions on request

5

screw

CuZn

M12

6 ... 8

0.25 ... 0.75

4

125

–40 ... 85

IP67

CuSnZn

Dimensions

appr

ox. 6

2

M12x1

Ø 19.6

Ø 6–8 mmCable bushing

Ø 6–8 mmCable bushing

M12x1

Ø 19.6

appr

ox. 5

7

Plug / socket

4-pole straight

Type Qty Order No.

SAIS-4-IDC-M12 (PB) 1 1864730000

SAIB-4-IDC-M12 (PB) 1 1864740000

Other versions on request

4

IDC

CuZn

M12

7 ... 8.8

0.25 ... 0.75

4

32

–25 ... 85

IP67

tinned

Dimensions

M12x1

app

rox.

48.

8

O20.5

app

rox.

52.

2

M12x1

O20.5

Page 22: Weidmuller SAI PI

22

Accessories

Protective caps for various distributors

Ordering data

Type Qty Order No.

SAI-SK-M8 50 1802760000

Protective cap M8 socket Dust cap for M12 plug

Ordering data

Type Qty Order No.

Dust cap for M12 plug (yellow) 50 1781520000

Protective cap M12 Universal socket

Ordering data

Type Qty Order No.

SAI-SK-M12-UNI 20 2330260000

Ordering data

Type Colour Order No.

TM sleeve TM 203/18 VO 1798480000

TM-I 18 NEUTRAL WS white 1718431044

TM-I 18 NEUTRAL GS yellow 1718431687

Ordering data

Type Colour Order No.

for SAI-Active Universal

ESG 8/13,5/43,3 SAI AU transparent 1912130000

HARAX® is a registered trademark of Harting KGaA.

The marker tags can be labelled quickly and reliably using Weidmüller’s PrintJet

marking system.

TM-I

Marking systemfor sensor cables

Markers in MultiCard format

Screwty® compatible, can also be operated by hand.

Page 23: Weidmuller SAI PI

23

Screwty® for M8 / M12

Accessories

The perfect tool for all situations

Screwty® is the ideal, universal tool for tightening and releasing cable

glands on all common sensor and actuator cables. The Screwty® can

also reach those round plug connectors normally considered inaccessible!

No great force is required – simply turn the tool to tighten or release the

plug connector as required.

The Screwty® also fits the majority (more than 90%) of the line and

plug connectors of other suppliers and is therefore a unique tool useful

throughout the world. The Screwty® consists of a handle with a conven-

tional 1/4" fitting. This means it can be used for all sizes: for M12 and M8

round plug connectors, and the M12F and M8F types, also for plugs

and sockets on custom cables.

The Screwty® is suitable for the following round plug connectors:

Size M8 M8F M12 M12F

10 ±0.3 mm 11.9 ±0.3 mm 14.5 ±0.3 mm 19.8 ±0.3 mm

Thread M8x1 M8x1 M12x1 M12x1

An adjustable torque fitting is also available for the Screwty® – for

guaranteeing extra reliability during installation.

The torque can be infinitely adjusted between 0.5 and 1.7 Nm. This

accurate setting enables all round plug connectors to be tightened

precisely with a certain torque.

Weidmüller specifies the following torques for its round plug connectors:

Size M8 M8F M12 M12F

Torque 0.5 – 0.6 Nm 0.5 – 0.6 Nm 0.8 – 1.0 Nm 0.8 – 1.0 Nm

Thread M8x1 M8x1 M12x1 M12x1

The Screwty® an also be fitted with other blades to create a torque screw-

driver. You can find these blades in the “Tools” section of the main

catalogue.

The following Screwty® models are available:

Ordering data

Type Use Qty Order No.

Screwty® M12 moulded M12 lines 1 1900000000

Screwty® M8 moulded M8 lines 1 1900010000

Screwty® M12 F M12 plugs for custom assembly 1 1900020000

Screwty® M8 F M8 plugs for custom assembly 1 1900030000

Screwty® M12 KO or SD 1 1900100000

Screwty® M8 KO or SD 1 1900110000

Screwty® M12F KO or SD 1 1900120000

Screwty® M8F KO or SD 1 1900130000

WK-1/4" (Screwty®) 1 1862200000

1/4"-Handhold 1 4294820000

Screwty®-M12-DM* moulded M12 lines with torque requirement 1 1900001000

Screwty®-M8-DM* moulded M8 lines with torque requirement 1 1900011000

Screwty®-M12 F-DM* M12 plugs, custom assembly w. torque requirement 1 1900021000

Screwty®-M8 F-DM* M8 plugs, custom assembly with torque requirement1 1900031000

Screwty®-Set* 1 1910000000

Screwty®-Set-DM* 1 1920000000

Other sizes in preparation

*) Fittings

Type Contents

Screwty®-M12-DM 1 interchangeable blade, 1 torque handle, 1 setting aid fo Screwty®

torque, 1 Screwty® M12 fitting

Screwty®-M8-DM 1 interchangeable blade, 1 torque handle, 1 setting aid fo Screwty®

torque, 1 Screwty® M18 fitting

Screwty®-M12 F-DM 1 interchangeable blade, 1 torque handle, 1 setting aid fo Screwty®

torque, 1 Screwty® M12 F fitting

Screwty®-M8 F-DM 1 interchangeable blade, 1 torque handle, 1 setting aid fo Screwty®

torque, 1 Screwty® M18 F fitting

Screwty® Set 1 Screwty® standard handle and one M12, M8, M12 F, M8 F fittings

Screwty® Set-DM 1 interchangeable blade, 1 torque handle, 1 setting aid for Screwty®

torque, 1 each of Screwty® M12, M8, M12 F, M8 F fittings

Simply turn the ratchet to tighten

or loosen the cable gland.

Legend:

F for custom assemblies

DM torque

KO or SD ratchet only (attachment)

Screwty® screwdriver, 4 ratchets

Screwty® DM torque screwdriver, 4 ratchets, interchangeable blade

WK interchangeable blade

Page 24: Weidmuller SAI PI

24

Sensor cables

Are you already a Weidmüller customer?

Why not buy your M12 or M8 cables from us as well?

Weidmüller has a wide range of M12 and M8 cables on offer.

And, as you would expect, Weidmüller quality also applies to

these articles.

Why take any risks?

In response to numerous customer requests, we have exten-

ded our portfolio to include:

• PVC cables

• PUR/PVC cables

• PUR halogen-free cables

… all that on top of fast delivery times and reasonable

conditions. Contact us and we will make you an offer. It costs

nothing to ask.

Page 25: Weidmuller SAI PI

25

Sensor cables

Connecting lines

Many applications with sensors require suitable connecting

cables. The connecting cables are available in different designs.

The M12/M8 plug-in connectors are available in straight and

90° versions and also with LEDs.

• When plugged in, the M12 connecting cables comply with

class of protection IP68.

• The cable sheathing is black and made of polyurethane

(PUR or PVC).

• The connecting cables are supplied with two marking

sleeves.

Corresponding tags TM-I 18 for the marking sleeves can be

found in this chapter.

Sensor cables

Weidmüller can supply various cable lengths as indicated in the

following table:

Typical cable lengths are:

Order No. code

Practical solutions based on practical experience

The coded order number represents an easy way of ordering

the cables you want from this wide range of products. The

cable length required is added to the 6-digit number specified

by Weidmüller (see example). The order numbers on the

following pages show the extensive range of cable lengths

available.

Example:

Ordering data for a cable

SAIL-M12G M12G-5-x.xU = 945734xxxx.

The placeholder “x” is replaced by the cable length.

The following example is for a line 1.2 m long.

SAIL-M12G M12G-5-1.2U = 9457340120.

In the case of connecting cables with two plug-in connectors,

the male end is always specified first and the socket end

second.

• 1.5 m • 3.0 m • 5.0 m • 10.0 m

M12/M12

M12/M8

Example of designation

S A I L - M 1 2 G M 8 W S - 2 / 4 S 1 . 5 U M12

M8

G = straightW = 90°

for M8

S = ScrewR = Clipfor M12 not specified

3 poli

4 poli

5 poli

2/4

bridged

Cable length

  1.5 m  3.0 m  5.0 m 10 m  X m

Cable

Q = PUR-PURV = PVC-PVCU = PUR-PVC

- = no optionsL = LED (for W only, not 2/4)S = shielded

M12

M8

G = straightW = 90°

Pin Socket

M8/M8

Page 26: Weidmuller SAI PI

26

Sensor cables with plug at one end only

Sensor/actuator cable pre-assembled with M8/M12

plug-in connector at one end

Machine designers frequently require individual line lengths.

Sensor cables with a connector fitted at one end only can

be easily adapted to the corresponding situation.

The cables are available in many different versions: straight,

90° and with all common pole numbers (3, 4 and 5). Plugs

and sockets can be assembled to suit individual customer

requirements for connecting cables.

The cable sheathing is of PUR (polyurethane) and is suitable for

use with cable carrier systems.

Plugs and cables are in neutral black.

Sensor cables

Weidmüller can supply various cable lengths as indicated in

the following table:

Typical cable lengths are:

Order No. code

Ordering data for a cable

SAIL-M12G M12G-5-x.xU = 945734xxxx.

The placeholder “x” is replaced by the cable length. The

following example is for a line 1.2 m long.

SAIL-M12G M12G-5-1.2U = 9457340120.

In the case of connecting cables with two plug-in connectors,

the male end is always specified first and the socket end

second.

Example of designation

• 1.5 m • 3.0 m • 5.0 m • 10.0 mM12 with plug or socket

at one end

M8 with plug or socket

at one end

M8 or M12 with LEDs

at one end

M8 or M12 shielded

at one end

S A I L - M 8 B G S - 2 / 4 S 1 . 5 U M12

M8

not specified = PinB = socket

G = straightW = 90°

for M8

S = ScrewR = Clipfor M12 not specified

3-poli

4-poli

5-poli

8-poli

12-poli

2/4

bridged

Cable length

  1.5 m  3.0 m  5.0 m 10 m   X m

Cable

Q = PUR-PURV = PVC-PVCU = PUR-PVC

- = no optionsL = LEDS = shielded

connector at one end only

Sensor cables

Page 27: Weidmuller SAI PI

27

Valve connector

Valve connector with integral seal

This range of valve connectors are fitted with a transparent

housing, which provides the added advantage of allowing the

operating status indicators to be seen from all sides. An additio-

nal seal is not needed in this case as it is already integrated in

the housing. In addition, a lug has been included in the con-

struction to ensure that the protective hose fits securely. All

variants are equipped with supprossor circuitry.

Weidmüller’s delivery programme includes valve connectors of

the types A, B and C to DIN and industrial standards.

Protection to IP67 is fulfilled when plugged. Socket or pin

connectors with various cable exits and a variety of pole

numbers can also be obtained from Weidmüller.

Type A

Type C with protective sleeve

Valve plugtype A

Valve plugtype B

Contact gab 18 mm

Type VSA

Contact gab 11 mm

works standard

Type VSB

Contact gab 10 mm

DIN 43650 (ISO 6952)

Type VSBD

Contact gab 9.4 mm

works standard

Type VSC

Contact gab 8 mm

DIN 43650 (ISO 6952)

Type VSCD

1 2

18

1 211

1210

129.

4

128

Valve plugtype C

1

2

brown

LEDyellow

blue

PE

PE

green/yellow

Page 28: Weidmuller SAI PI

28

Appendix

UAEUnited Arab EmiratesWeidmüller Middle-EastP.O. Box 62448DubaiPhone +971 4 3522215, 3523043Fax +971 4 [email protected]

ArgentinaCPI SABauness 26601431 Buenos AiresPhone +54 11 45238008Fax +54 11 [email protected]

AustriaWeidmüller Ges.m.b.H.Industriezentrum Nö SüdStraße 2, Objekt M22355 Wiener NeudorfPhone +43 2236 6708-0Fax +43 2236 [email protected]

AustraliaWeidmüller Pty. Ltd.43 Huntingwood DriveHuntingwood,NSW, 2148P.O.Box 6944BlacktownNSW, 2148Phone +61 2 9671-9999Fax +61 2 [email protected]

AzerbaijanWest Industries Ltd. Caspian Plaza, 5-th Floor 44 J. Jabbarly Str., Baku, Azerbaijan Phone +99412 499 15 15 Fax +99412 499 14 93 [email protected]

Bosnia-HerzegovinaBH ES Elektrosistem d.o.o.ul. J. Veselinovica 1878000 Banja LukaBosnaPhone +387 51 317500Fax +387 51 [email protected]

BelgiumWeidmüller Benelux B.V.Ambachtenlaan 11 A3001 HeverleePhone +32 16 395990 Fax +32 16 [email protected]

BulgariaWeid-Bul eOOdul. Nezabravka 33 A, bl. 315/3/101113 SofiaPhone +359 2 9632560Fax +359 2 [email protected]

BahrainKhayber Trading CompanyP.O. Box 1976 Manama, BahrainPhone +973 17720747 Fax +973 17720331 [email protected]

BrazilConexel Conexoes Elétricas Ltda.Rua Garcia Lorca, 176- V. Paulicéia, 09695-900, Sao Bernado do Campo - SP, BrasilPhone +55 11 43669600Fax +55 11 [email protected]

BelarusTECHNIKON Ltd.Oktyabrskaya Str. 16/5 Apt. 704 220030 Minsk Belarus Phone +375 17 2104626Fax +375 17 [email protected]

BY

BR

BH

BG

BE

BA

AZ

AU

AT

AR

AE CanadaW Interconnections Canada Inc.10 Spy Court, Markham, Ontario L3 R5 H6Phone +1 905 475-1507Fax +1 905 [email protected] www.weidmuller.ca

SwitzerlandWeidmüller Schweiz AGRundbuckstrasse 28212 Neuhausen am RheinfallPhone +41 52 6740707Fax +41 52 [email protected]

ChileFelipe Bahamondes S.A./ATS AGROServicios AgroindustrialesMaria Luisa Santander 0475ProvidenciaCasilla 3425SantiagoPhone +56 2 341-1271Fax +56 2 [email protected]

ChinaWeidmüller Interface InternationalTrading (Shanghai) Co., Ltd.12 F, Century Ba-Shi Building,No. 398 Huaihai Road (M)Shanghai 200020P.R. China Phone +86 21 63868188Fax +86 21 63867177www.cnweidmuller.com

ColombiaAutomatizacion Avanzada S. A.Carrera 97 No. 42 A-23 B3, Santafe de Bogotá Colombia.Phone +57 1 4132048 Fax +57 1 [email protected]

Costa RicaELVATRON S.A.400 Norte Banco Costa Rica, la Uruca, San José, Costa RicaPhone +506 2 961060 Fax +506 2 960328 [email protected]

Serbia and MontenegroES-YU ElektrosistemPariske komune 4111070 Novi Beograd SerbiaPhone +381 11 697212 Fax +381 11 693608 [email protected]

Czech RepublicWeidmüller s. r. o.Videnska ul. 34025242 Vestec u PrahyPhone +420 2 44001400Fax +420 2 [email protected]

GermanyWeidmüller GmbH & Co. KGOhmstraße 932758 DetmoldPhone +49 5231 1428-0Fax +49 5231 [email protected]

DenmarkKnud Wexøe A/SSkaettekaeret 11P.O. Box 1522840 HoltePhone +45 45465800Fax +45 45465801 [email protected]

EstoniaAlter Electric OÜTüri 6, 11313 Tallinn, EstoniaPhone +372 65 19 666Fax +372 65 [email protected]

EE

DK

DE

CZ

CS

CR

CO

CN

CL

CH

CA EgyptStandard Electric87, Mohamed Farid Street Heliopolis, Cairo, EgyptPhone +20 6 42 29 77/ 6 42 29 88Fax +20 6 42 29 [email protected]

SpainWeidmüller S. A.Narcis Monturiol 11-13Pol.Ind. Sudoeste08960 Sant Just DesvernBarcelonaPhone +34 93 4803386Fax +34 93 [email protected] www.weidmuller.es

FinlandJUHA-ELEKTRO OYKylvöpolku 6, P. O. Box 5700681 HelsinkiPhone +358 9 478411Fax +358 9 47841311

FranceWeidmüller EURL12, Chaussée Jules CésarB.P. 263 Osny95523 CERGY PONTOISE CedexPhone +33 1 34245500Fax +33 1 [email protected]

United KingdomWeidmuller Ltd.1 Abbey Wood RoadKings Hill, West MallingKent ME19 4YTPhone +44 1732 877000Fax +44 1732 [email protected]

GreeceElectrorama S.A.1 An. Martali Str.41335 LarissaPhone +30 2410 552533 Fax +30 2410 283463 [email protected]

Hong KongUnited Equity LimitedSuite B, 11/F International IndustrialCentre2-8 Kwei Tei Street, Fotan, ShatinHong KongPhone +852 26876739Fax +852 [email protected]

CroatiaElektro Partner d.o.o.Radnicka cesta 2210000 ZagrebPhone +385 1 6184793Fax +385 1 [email protected]

HungaryWeidmüller Kereskedelmi KftDombóvári út 13 1117 BudapestP. O. Box 221507 BudapestPhone +36 1 464-7888Fax +36 1 [email protected]

IndonesiaP. T. Nego ElectrindoKomplek Sentra Kramat, Blok A18Jl. Kramat Raya No. 7-9Jakarta 10450 IndonesiaPhone +62 21 3156218Fax +62 21 [email protected]

IrelandA.P. Haslam Ltd.14 Sunshine Ind. EstateCrumlin RoadDublin 12Phone +353 1 453-2522 Fax +353 1 [email protected]

IE

ID

HU

HR

HK

GR

GB

FR

FI

ES

EG IsraelA.U. Shay Ltd.Embar Street 23/25P.O.Box 10049Petach-Tikva 49222Phone +972 3 9233601Fax +972 3 [email protected]

IndiaWeidmüller Representative officeVijay Dattani# 156-4th cross, Prashant ExtensionWhitefieldBangalore - 560 066Phone +91 80 [email protected]

IranTAF Co.72, Iranshahr Av.Unit 5, 15816 TeheranPhone +98 21 8831-7851Fax +98 21 [email protected]

IcelandSamey Automation CenterLyngas 13, 210 Garoabaer,IcelandPhone +354 510 5200Fax +354 510 [email protected]

ItalyWeidmüller S.r.l.Via Albert Einstein 420092 Cinisello BalsamoMilanoPhone +39 02 660681Fax +39 02 [email protected]

JordanHorizons Engineering P.O. Box 330607 ZC 11133 Amman Phone +962 64882114 Fax +962 4882115 [email protected]

JapanNihon Weidmüller Co. Ltd. Asahi Seimei Bldg. 11F1-14-1 Fuchucho Fuchu-shiTokyo 183-0055 JapanPhone +81 42 330-7891 Fax +81 42 330-7895www.weidmuller.co.jp

South KoreaWeidmüller Co., Ltd.2 floor Wooam B/D 46-27Samsung2-Dong, Kangnam-KuSeoul Korea, Zip: 135-868Phone +82 2 5160003 Fax +82 2 [email protected]

KuwaitNOURI Industrial Establishment Co.P.O.Box 2829, Safat 13029 KuwaitPhone +965 4333355Fax +965 [email protected]

KazakhstanSEA STAR58-A, Office 609, Abilay Khan Aven.Almaty, 50004KazakhstanPhone +7 3272 733307Fax +7 3272 [email protected]

KazakhstanElectric Light LLP84, Auezov StreetOffice 310480057 AlmatyKazakhstanPhone +7 3272 421709Fax +7 3272 [email protected]

KZ

KZ

KW

KR

JP

JO

IT

IS

IR

IN

IL

Worldwide activities

Page 29: Weidmuller SAI PI

29

Appendix

LebanonProgress Engineering & TradingEnterprisesP.O. Box 11-1111Pharaon Bldg., Opp Electr. du LibanChafaca Str., Al NahrBeirut - LebanonPhone +961 1 444664Fax +961 1 [email protected]

LithuaniaELEKTROS IRANGATinklu g.29a, 5319 Panevezys,LithuaniaPhone +370 45582828Fax +370 [email protected]

LuxembourgPlease contact Weidmüller Belgium, Heverlee

LatviaElektrosistemas SIAK. Ulmana gatve 140LV-1029 RigaLatviaPhone +371 7870557Fax +371 [email protected] www.profs.lv

MacedoniaES MK Elektrosistem d.o.o.Ul. Bulevar III makedonske brigade bb91000 SkopljeMacedoniaPhone +389 91 460295Fax +389 91 [email protected]

MexicoW Interconnections, S.A. de C.VAv. Ingenieros Civiles No. 204-B, Conjunto Industrial Chachapa72990 Chachapa, Puebla MexicoPhone +52 222 2866247/48/49Fax +52 222 [email protected]

MalaysiaConnect Plus Technology Sdn Bhd9, Jalan PJS 11/24,Bandar Sunway,46150 Petaling Jaya,Selangor Darul Ehsan,MalaysiaPhone +60 3 5633 7363Fax +60 3 5633 [email protected]

NetherlandsWeidmüller Benelux B.V.Franciscusweg 2211216 SE HilversumPostbus 15051200 BM HilversumPhone +31 35 6261261Fax +31 35 [email protected]

NorwaySiv. Ing. J. F. Knudtzen A/SBillingstadsletta 971396 Billingstad, P.O. Box 1601378 NesbruPhone +47 66 983350Fax +47 66 [email protected]

New ZealandCuthbert S. Steward Limited27 Te Puni StreetPOB 38496 PetonePetone, WellingtonPhone +64 4 5686156Fax +64 4 5686056

Oman DAN INTERNATIONAL LLC. PO.BOX 2901 111 Seeb Oman Phone +968 503 677 Fax +968 503 755 [email protected]

OM

NZ

NO

NL

MY

MX

MK

LV

LU

LT

LB PeruTECNOLOGÍA ELÉCTRICAY SOLUCIONES S.A.C.Calle Huandoy 501, Lima 32 – PerúPhone +51 1 5620004Fax +51 1 [email protected]

PhilippinesEl Criscent CorporationB-41 L-10, Villa Palao,Banlic, Calamba City Laguna 4027,PhilippinesPhone +63 49 3456329Fax +63 49 [email protected]

PhilippinesEnclosure Systems Specialists IncG/F, GE Building2291 Don Chino Roces Ava ExtMakati City 1231,PhilippinesPhone +63 2 813 8580Fax +63 2 813 [email protected]

PolandWeidmüller Sp. z o.o.ul. Goledzinowska 1003-302 WarszawaPolandPhone +48 22 5100940Fax +48 22 [email protected]

PortugalWeidmüller - Sistemas de Interface, S. A.Estrada Outeiro Polima, Lote B, N° B2, Escritório 2 - Abóboda2785-518 Sao Domingos de RanaLisboaPhone +351 21 4459190Fax +351 21 [email protected] www.weidmuller.pt

ParaguayRewo Paraguay S.A.Sucre 2590 esq Emeterio MirandaAsunciónParaguayPhone +595 21 60 60 13Fax +595 21 60 60 [email protected]

QatarDoha Motors (Technical Division) Post Box No. 145 Al Wakrath Road Doha-Qatar Phone +974 465 1441 Fax +974 465 4579 [email protected]

Romania Rominterface Impex SRL Str. Gh. Dem Teodorescu 30A 030916 Bukarest - sector 3 Phone +40 21 3220230Fax +40 21 [email protected]

RussiaWeidmüller Representative Office Shabolovka street 2119049 Russia, MoskauPhone +7 495 771-6940Fax +7 495 [email protected]

Saudi ArabiaAl Abdulkarim Trading P.O. Box 5777, Dammam 31432 Saudi ArabiaPhone +966 3 833-7110Fax +966 3 [email protected]

SA

RU

RO

QA

PY

PT

PL

PH

PH

PE Saudi ArabiaSaudi Electric Supply Co.P.O. Box 3298, Al Khobar 31952 Saudi ArabiaPhone +966 3 882-9546227Fax +966 3 [email protected]

SwedenWeidmüller ABStockholm, Arenavägen 39, 12177 JohanneshovP.O. Box 1012012128 Stockholm-GlobenPhone +46 771 43 00 44Fax +46 8 [email protected]

SingaporeWeidmüller Pte. Ltd.629 Aljunied Road, #05-05Cititech Industrial BuildingSingapore 389838Phone +65 6841 5311Fax +65 6841 [email protected]

SloveniaELEKTROSPOJI d.o.o.Stegne 251000 LjubljanaPhone +38 6 15113810 Fax +38 6 [email protected]

SlovakiaElektris s.r.o.Racianska 188SK 83153 Bratislava, Slovakia Phone +421 2 49200113Fax +421 2 [email protected]

Syria Hovaguimian Bros. P.O. Box 5093 Damascus Syria Phone +963 11-221 84 05 Fax +96311-224 48 69 [email protected]

ThailandPisanu Engineering Co., Ltd 800/2 Asoke Dindaeng Road, Dindaeng, Bangkok 10400ThailandPhone +66 2 2459113 Fax +66 2 [email protected]

TurkeyWeidmüller Elektronik Ticaret Ltd. Sti.Kavacik Mah. Mihrabad Cad. 143/134810 Beykoz –

.Istanbul / Turkey

Phone +90 216 5371070 (Pbx)Fax +90 216 [email protected]

TaiwanFittatek Co., Ltd.12 F No. 185 Fu-Kuo Road, Tso Ying Dist, Kaohsiung, TaiwanPhone +886 7556-0858 Fax +886 [email protected]

TaiwanEucan Enterprise Ltd.No. 145 He Ping 2nd RdKaohsiung, TaiwanPhone +886 7 715 6610Fax +886 7 715 [email protected]

UkraineTEKO InterfacePer.Industrialny 203056 - KievPhone +380 04463 57760Fax +380 04463 [email protected]

UA

TW

TW

TR

TH

SY

SK

SI

SG

SE

SA USAW-Interconnections, Inc.821 Southlake Boulevard,Richmond, VA 23236Phone +1 804 7942877Fax +1 804 [email protected]

Uruguay Rewo Uruguay S.A. AV. Bolivia 2001 Esq Rocafuerte Carrasco Montevideo Phone +598 260 4 8439 Fax +598 260 4 8439 [email protected]

VenezuelaSomerinca C. A.Edificio Esteban Piso 2Calle Vargas Bolleita Notre Caracas 1070 AVenezuelaPhone +58 212 2352748Fax +58 212 [email protected]

VietnamNew Sky Co., Ltd 206 Nguyen Thai Binh Str., Ward 12., Tan Binh Dist.,Ho Chin Minh CityVietnam Phone +848 811 6768Fax +848 811 [email protected]

YemenPlease contact Weidmüller Middle-East United Arab Emirates

South AfricaRAD Interface Pty. Ltd.5 Bundo RoadSebenza ExtensionEdenvale 1609P.O.Box 193Edenvale 1610Phone +27 11 452-1930Fax +27 11 [email protected]

Other countriesWeidmüller Interface GmbH & Co. KGP.O. Box 303032720 DetmoldKlingenbergstraße 1632758 DetmoldPhone +49 5231 14-0Fax +49 5231 14-20 [email protected]

DE

ZA

YE

VN

VE

UY

US

DE Group companies

DE Agency abroad

DE Without own Agency

Page 30: Weidmuller SAI PI

30

Appendix

We cannot guarantee that there are no mistakes in thepublications or software provided by us to the customer for thepurpose of making orders. We try our best to quickly correcterrors in our printed media. For this purpose we list corrections,which have been identified after publishing printed media, on ourweb site at www.weidmueller.com. For convenience we list thesecorrections against product catalogue number and/or pagenumber. This Internet-database is part of our catalogue.

All orders are based on our general terms of delivery, which canbe reviewed on the websites of our group companies where youplace your order. On demand we can also send the general termsof delivery to you.

Page 31: Weidmuller SAI PI
Page 32: Weidmuller SAI PI

Order number:

5654350000/04/2006/DMMD

www.weidmueller.com

ArgentinaAustraliaAustriaAzerbaijan BahrainBelarusBelgiumBosnia-HerzegovinaBrazilBulgariaCanadaChileChinaColombiaCosta RicaCroatiaCzech RepublicDenmarkEgyptEstoniaFinlandFranceGermanyGreeceHong KongHungaryIcelandIndiaIndonesiaIran

IrelandIsraelItalyJapanJordanKazakhstanKuwaitLatviaLebanonLithuaniaLuxembourgMacedoniaMalaysiaMexicoNetherlandsNew ZealandNorwayOmanParaguayPeruPhilippinesPolandPortugalQatarRomaniaRussiaSaudi ArabiaSerbia/MontenegroSingaporeSlovakia

SloveniaSouth AfricaSouth KoreaSpainSwedenSwitzerlandSyriaTaiwanThailandTurkeyUAEUkraineUnited KingdomUruguay USAVenezuelaVietnamYemen

Weidmüller is the leading manufacturer of componentsfor electrical connection technology. The Weidmüller product portfolio ranges from terminal blocks, PCB connectors and terminals, protected components, Industrial Ethernet components and relay sockets to power supply and overvoltage protection modules suitable for all applications. Electrical installation andmarking material, basic I/O components and a variety oftools round off the range. As an OEM supplier, the company sets global standards in the field of electricalconnection technology.