welcome to windhager zentralheizung gmbh. wärme in perfektion. biowin –...
TRANSCRIPT
![Page 1: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/1.jpg)
Welcome toWelcome to
Windhager Zentralheizung Windhager Zentralheizung GmbHGmbH
![Page 2: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/2.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – Pellets-Central-Heating-System
The new Pellets-Comfort
Output: 2,9 - 25,9 kW
![Page 3: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/3.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – Pellets-Central-Heating-System
Overview:
1. Boiler types2. Assembly and Function
3. Handling
4. Cleaning
5. Pellets-storage & -feeding
6. Planning
7. Systems
![Page 4: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/4.jpg)
Wärme in Perfektion.www.windhager.com
To be used at Low-Energy-Houses till 2-Family-Houses
4 sizes of output:
BW_100: 2,9 – 10 kW
BW_150: 5,0 – 15 kW
BW_210: 6,5 – 21 kW
BW_260: 8,0 – 25,9 kW
![Page 5: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/5.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – the new Pellets-Central-Heating-Comfort3 Classes of Comfort: ExklusivExklusiv
Feeding unit
Ash-discharge
Heating surface cleaningPremiumPremiumFeeding unit
Ash box
Cleaning leverKlassikKlassikStorage room
Ash box
Cleaning lever Support rate
Till 1 Week
Till 2 Months
Till 1 Year
![Page 6: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/6.jpg)
Wärme in Perfektion.www.windhager.com
24 Boiler-Possibilities – Solutions for every need and budget
4 sizes of output(10, 15, 21 & 26 kW)
x 3 classes of comfort (Klassik, Premium & Exklusiv)
x 2 controls(MES & REG)
= 24 boiler-possibilities!!= 24 boiler-possibilities!!
![Page 7: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/7.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – Pellets-Central-Heating-System
Overview:
1. Boiler types
2. Assembly and Function3. Handling
4. Cleaning
5. Pellets-storage & -feeding
6. Planning
7. Systems
![Page 8: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/8.jpg)
Wärme in Perfektion.www.windhager.com
Fully automatic pellets-feeding-unit
Burner-bowl
Fully automatic ash-discharge
For ~ 150 kg Pellets
ash box
Switchboard InfoWIN
Integrated ash box
Pellets-storage tank
Maintenance-free system with sound-absorbing
In high heat-resisting high grate steel
Burner-room and heating-surface
With full-text-display
Clocked dosing conveyor screwFor modulating performance
BioWIN – thought out to the detail
Fully automatic burner-grate-ash-
dischargeOf the heating-surface
![Page 9: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/9.jpg)
Wärme in Perfektion.www.windhager.com
Feeding from the storage tank
Pellets supply
Automatic ignition
Heating operation
BioWIN – burning procedure
![Page 10: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/10.jpg)
Wärme in Perfektion.www.windhager.com
Basic: burner-systems
From below:
advantage:•High output•For wood-chips & pellets
disadvantage:•not 100 % combustion•No back-burning safety•Inexact control of burning
![Page 11: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/11.jpg)
Wärme in Perfektion.www.windhager.com
Basic: burner-systems
From the side:
advantage:•High output•For wood-chips & pellets•Also for wet fuel
disadvantage:•not 100 % combustion•No back-burning safety•Inexact control of burning
![Page 12: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/12.jpg)
Wärme in Perfektion.www.windhager.com
Drop system:
advantage:•Back-burning safety•100 % combustion•Exact control of combustion
disadvantage:•cleaning•„only“ for pellets
Basic: burner-systems
![Page 13: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/13.jpg)
Wärme in Perfektion.www.windhager.com
Pellets- or drop systemadvantage:
Pellets without connection to the burning zonehomogeneous, non compressed burning zoneNo wear constructionExact combustionLong-term best combustion-results Total combustionLow ash contentAutomatic ash grate cleaning
![Page 14: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/14.jpg)
Wärme in Perfektion.www.windhager.com
Lambda probe Thermo probe?
Lambda probe
Exhaust-sensor
Measurement of rest-oxygen in the exhaust-gas
Directly in the exhaust-gaspollution of the sensor
Expensive sparepart
Thermo probe
Temperature-sensor
Measurement of temperature
Installed in protection pipeno pollution !!!
Cheap sparepart
![Page 15: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/15.jpg)
Wärme in Perfektion.www.windhager.com
Thermo control: long-term control of combustion
advantage: Active control (combustion-temperature)sensitive dosage of fuel and air Best combustion-values over years and over
the full modulating rangeVery high firing efficiencyLambda-probe free !!!
![Page 16: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/16.jpg)
Wärme in Perfektion.www.windhager.com
Modulating boiler-output – heat how you need it
with switch on/off modulation starting at 30% output
Save heating costs Minimise emissions Improve efficiency-rate Extend life-cycle
![Page 17: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/17.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – Pellets-Central-Heating-System
Overview:
1. Boiler types
2. Assembly and Function
3. Handling4. Cleaning
5. Pellets-storage & -feeding
6. Planning
7. Systems
![Page 18: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/18.jpg)
Wärme in Perfektion.www.windhager.com
Kesseltemperatur
55Menü
°C
InfoModulationsbetrieb
switchboard InfoWIN
On/off-switch
check-light
operating-phase
Menu-line
Lighted display
Manual-/Chimney-sweeper
Menu for buttons
Menu-buttons
![Page 19: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/19.jpg)
Wärme in Perfektion.www.windhager.com
InfoWIN – basic functions
Check-light:„operation“ = green „failure“ = red
On/off-switchPower supply of extern units (control, pumps, mixer, ...) persist
Kesseltemperatur
55Menü
°C
InfoModulationsbetrieb
![Page 20: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/20.jpg)
Wärme in Perfektion.www.windhager.com
Kesseltemperatur
55Menü
°C
ModulationsbetriebInfo
InfoWIN – Info-text
Info-text: boiler-temperature actual value (°C) boiler-temperature set-point (°C) exhaust-temperature (°C) actual boiler-output (%) operation-hours (Std.) clock software version InfoWIN software version firing-automat boiler-type
Betriebsstunden
zurück1.238
h
![Page 21: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/21.jpg)
Wärme in Perfektion.www.windhager.com
Kesseltemperatur
55°C
InfoModulationsbetriebModulationsbetrieb
Menü
InfoWIN – chimney-sweeper-functionChimney-sweeper-function: switch on: short push on button
Max./Min. output: selection over menu-button
Finish: push „Abbruch“-button automatically after 45 Min.
KaminkehrerfunktionLeistung 100%
Abbruch
°C5530% 100%
![Page 22: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/22.jpg)
Wärme in Perfektion.www.windhager.com
Kesseltemperatur
55Menü
°C
InfoModulationsbetrieb
InfoWIN – Manuel
Menu-structure: „Betreiberebene“ changing of the basic-adjustment from the enduser
„Serviceebene“ ONLY for briefed personal
wählen
BetreiberebeneServiceebene
zurück
![Page 23: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/23.jpg)
Wärme in Perfektion.www.windhager.com
InfoWIN – Manual„Betreiberebene:“ „Uhrzeit“ only without MES „Betriebsart Zuführung“ - with „Freigabezeit“ - with „Startzeit“ - without „Zeitsteuerung“ - „ausgeschaltet“„Zeitprofil Zuführung“ Beginn/end „Freigabezeit“ or „Startzeit“ „Sondenumschaltung“ - „automatisch“ - „only Probe 1, 2 oder 3“
zurückwählen
UhrzeitBetriebsart ZuführungZeitprofil ZuführungSondenumschaltung
![Page 24: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/24.jpg)
Wärme in Perfektion.www.windhager.com
InfoWIN – troubleshooting
troubleshooting:Check-light shows „red“ Display failure-info (blink)
Gebläse defekt
Al 01642°C
!
Info
Push info-button: display Info text
Some failures are repairable by the customers themselves (no technician necessary!!!)
Gebläse defekt
a) Steckverbindung prüfen
b) Gebläserad reinigen und Leichtgängigkeit prüfen
zurück
![Page 25: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/25.jpg)
Wärme in Perfektion.www.windhager.com
InfoWIN – easy & save information is easier to understand, more details are shown in
two levels
enduser briefed technicians& chimney sweeper
profit:
- easy & clear- „Hilfetext“ is shown- full-text-display for more safety- in future on every WINDHAGER-boiler - multilingual programming possible
![Page 26: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/26.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – Pellets-Central-Heating-System
Overview:
1. Boiler types
2. Assembly and Function
3. Handling
4. Cleaning
5. Pellets-storage & -feeding
6. Planning
7. Systems
![Page 27: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/27.jpg)
Wärme in Perfektion.www.windhager.com
Burning residues are great isolators !!!
Thickness of residues in mmIncr
ease
of
exha
ust-
gas-
tem
pera
ture
in °
K
![Page 28: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/28.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN & cleaning ?
Cleaning-tools
![Page 29: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/29.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN - Ash–recycling
Exklusiv: empty ash box (till 1 year)
Premium & Klassik: empty ash box & use the cleaning-lever (~ every 2 months)
![Page 30: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/30.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN - Checklist
Deflector-plate: cleaning
Thermocontrol-sensor: cleaning
Water-tank: refill
![Page 31: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/31.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – Combustion-chamber
Combustion-chamber: cleaning:1. Hoover the chamber2. Replace the cone3. Hoover once more4. Replace the primary air throne5. Hoover once again6. Replace the ash-grate-plate7. Hoover the last time
![Page 32: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/32.jpg)
Wärme in Perfektion.www.windhager.com
Draught-fan: Cleaning and check smooth
running
Daily-storage-tank: Cleaning and refill
Storage-room: Cleaning every 3 years
BioWIN – anual checklist
![Page 33: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/33.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – fully automated cleaning
Automatic burner-grate-ash-dischargecleans periodical
Automatic heating-surface-cleaningTo save a constantly high efficiency the heating surfaces are cleaned steady (Exklusiv).
Automatic ash-discharge from burner-room and heating-surface
2 conveyor-screw deliver the ash to the integrated ash-box (Exklusiv)
![Page 34: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/34.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – Pellets-Central-Heating-System
Overview:
1. Boiler types
2. Assembly and Function
3. Handling
4. Cleaning
5. Pellets-storage & -feeding6. Planning
7. Systems
![Page 35: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/35.jpg)
Wärme in Perfektion.www.windhager.com
Full-automatic Pellets-feeding-unit
Change-over-unit
3 suction-probes
European-wide patented pneumatic suction unit
Fully automated change-over-unit with 3 suction-probes
![Page 36: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/36.jpg)
Wärme in Perfektion.www.windhager.com
Feeding-unit - components
Feeding-unit:• suction-turbine• cyclone• storage-room
3 suction-probes
Change-over-unit
Feeding- & return hose
![Page 37: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/37.jpg)
Wärme in Perfektion.www.windhager.com
Feeding-unit - function
1. Storage-room empty / „Sperrzeit“ starts / „Startzeit“ starts
2. Suction-turbine (no filter!!!) starts & sucks Pellets
3. Pellets fall over cyclone in storage room
4. Return-air goes back to probe (closed circuit – no dust in storage-rooms)
5. Suction-turbine stops after programmed interval-time
6. Pellets-container-flap opens and fills pellets-tank
7. This procedure repeats till container is filled (switch at top of the container)
![Page 38: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/38.jpg)
Wärme in Perfektion.www.windhager.com
Unique-patented-solution
optimum immunity because of 3 probes in the storage room
position of storage room is independent of heating-room
maintenance-free system
fullautomatic function-control
flushing – when blockage caused by foreign substance, the forward- and return flow changes 180° - the probes get flushed Change-over – if the flushing does not solve the problem the system switches automatically to the next probe no interruption of the operations!
![Page 39: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/39.jpg)
Wärme in Perfektion.www.windhager.com
Diverse possibilities of pellets-storage
„classic“ storage room Steel-plate-tank
Texture-tank Plastic-tank
![Page 40: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/40.jpg)
Wärme in Perfektion.www.windhager.com
„classic“ pellet-storage-room
![Page 41: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/41.jpg)
Wärme in Perfektion.www.windhager.com
example: heating-demand of building: 15 kW X0,9= storage-room-volume 13,5 m3 (incl. Head-
space) Equivalent with a room of 2 x 3 x 2,25 m
Rule of thump:Heating-demand of building (kW) x faktor 0,9 = storage-
room-volume (m3)
Dimensions
Should be at least 1-year-amount of fuel Size depends on heating demand of building
![Page 42: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/42.jpg)
Wärme in Perfektion.www.windhager.com
Lagerraum-Schnitt
![Page 43: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/43.jpg)
Wärme in Perfektion.www.windhager.com
Topview
![Page 44: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/44.jpg)
Wärme in Perfektion.www.windhager.com
Dry, tight and solid
Walls and ceiling – fire-resistance-class F 90
Door or access-door should open outwards, fire-resistant-class T 30
No electric installations (except e-installations in explosion-proof design))
No liquid-bearing pipes/lines (condensing or burst of pipes)
Design (ÖNORM M7137 bzw. TRVB H118):
„classic“ pellet-storage-room
![Page 45: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/45.jpg)
Wärme in Perfektion.www.windhager.com
Wooden boards at the inside of the door – pelets should not press at the door
Z-angel-profile (PMX 016)
Access-door:
Wooden boards (3 cm dick)
Fire-resistant door T 30
„classic“ pellet-storage-room
![Page 46: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/46.jpg)
Wärme in Perfektion.www.windhager.com
Always 2 connections PMX 014 (System Storz, Typ A Ø 100 mm)
Connection should be on the small side Return-connection must be always free, also at full-filled
storage-room Storage-room inside the house:
connections till outside, connection-pipe made of metal, fire-resistant-class F 90 and mounted on the wall (grounded)
Feeding- and return-connection:
„classic“ pellet-storage-room
![Page 47: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/47.jpg)
Wärme in Perfektion.www.windhager.com
Connection on smaller side:
„classic“ pellet-storage-room
Connection on wider side:
![Page 48: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/48.jpg)
Wärme in Perfektion.www.windhager.com
Free of any form of dirt (small stones, pieces of wood etc.)
deflector opposite of feeding- and return-connectors
No damaging of walls - pieces of wall may fall into suction-turbine and blockade suction-system or conveyor screw .
construction:
„classic“ pellet-storage-room
![Page 49: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/49.jpg)
Wärme in Perfektion.www.windhager.com
Steel-plate-tank for pellets
![Page 50: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/50.jpg)
Wärme in Perfektion.www.windhager.com
18 sizes (from 2,2 till 9,6 to pellets):Wide: 1,5m
length: 1,5m, 2m, 3m, 3,5m und 4mheight: 2,2m und 1,9m
Wide: 2,0mlength: 2m, 3m, 3,5m und 4mheight: 2,2m und 1,9m
zinc-coated steel-plates in modular design extraction with 2- or 3 probes and change-over-unit perfect for reconstruction (wet basement)
Steel-plate-tank for pellets
![Page 51: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/51.jpg)
Wärme in Perfektion.www.windhager.com
Steel-plate-tank for pellets
1,9 or 2,2 m height
![Page 52: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/52.jpg)
Wärme in Perfektion.www.windhager.com
Texture-tank for pellets
![Page 53: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/53.jpg)
Wärme in Perfektion.www.windhager.com
Texture-tank for pellets
3 sizes:
1,7 x 1,7m for approx. 2 – 3,2 to
2,1 x 2,1 m for approx. 3 – 4,7 to
2,5 x 2,5 m for approx. 5 – 6,7 to
Atvantage to competitors:
Extraction with 2 probes and change-over-unit!
![Page 54: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/54.jpg)
Wärme in Perfektion.www.windhager.com
Reference to partners:
Plastic-tank for underground-storage of pellets
Geoplast GmbH
www.pelletstank.com
NAU GmbH
www.nau-gmbh.de
![Page 55: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/55.jpg)
Wärme in Perfektion.www.windhager.com
BASIC: Max. conveying-lenght: 15m
Max. conveying-height: 2,8m
Min. hose-bend-radius: 30cm
Important: Feeding-hose in one piece
Return-hose can be more pieces
Hoses should not be placed up and down
Details for hose-mounting
calculation:distance – feeding-unit to change-over-unit distance: ..... ....m x 2 = ..........m
distance – feeding-unit to suction-probe 1 distance: .............m x 2 = ..........m
distance – feeding-unit to suction-probe 2 distance: .............m x 2 = ..........m
distance – feeding-unit to suction-probe 3 distance: .............m x 2 = ..........m
nessassary hose-lenght: ..........m
TIP: put the hoses in 80mm plastic-tubes !!!
![Page 56: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/56.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – Pellets-Central-Heating-System
Overview:
1. Boiler types
2. Assembly and Function
3. Handling
4. Cleaning
5. Pellets-storage & -feeding
6. Planning7. Systems
![Page 57: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/57.jpg)
Wärme in Perfektion.www.windhager.com
Technical dataBW 100 BW 150 BW 210 BW 260
Nennwärmeleistungsbereich kW 2,9 - 9,9 4,3 - 15 6,3 - 21 7,5 - 25,9Rücklauftemperatur mindestens °CKesselwasserinhalt l 59 59 53 53Pelletsbehälter l/kg
Nettogewicht klassik
premiumexklusiv
kg
Einbringmaße B x T x H mmAbgastemperatur Nennlast/Teillast °C 114 / 76 136 / 82 144 / 84 154 / 85Volumenkonzentration an CO2 Nennlast/Teillast % 11,7 / 8,2 13,3 / 9,7 14,0 14,8 / 11,8Abgasrohranschluss Ø mm
elektrische Leistungsaufnahmemaximal beim Zünden Wmittlere Leistung beim Zünden W 591 591 607 607durchschnittliche Zündzeit min 3,86 3,86 4,35 4,35elektrische Arbeit beim Zünden Wh 38 38 44 44Heizbetrieb Teillast/Nennlast W 41,9 / 68 53,1 / 88,5 47,7 / 107,3 47,7 / 107,3Schlummerbetrieb Wautomatische Pelletszuführung WStromaufnahme maximal A 5,8 5,8 5,8 5,8
1580
130
20
232 / 150,8
Pellets-central-heating-boiler BioWIN
860
6,3
318318333
329329344
1200x790x1610 (getrennte Einbringung möglich!)
![Page 58: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/58.jpg)
Wärme in Perfektion.www.windhager.com
Heating-unit
Internal return temperature of 20°C possible! Serially internal return temperature rising External return temperature rising only by
loading an accumulator-tank directly Terminal safety device only for 21 and 26 kW
necessary
Minimum boiler temperature 60°C For each heating circuit one motor mixing
valve
Motor mixer valve
![Page 59: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/59.jpg)
Wärme in Perfektion.www.windhager.com
In principal a buffer-tank is not necessary for a normal pellet-boiler-system!
BASIC:
Minimum heat-consumption is given (e.g. 1 radiator with open valves)
boiler-size is calculated with heating-demand of building
BioWIN & buffer-tank combination?
![Page 60: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/60.jpg)
Wärme in Perfektion.www.windhager.com
Exceptions:
1. We recommend a buffer-tank when the heating-demand of the building < 50% boiler-output
2. If the heating demand of the house < 5kW a buffer-tank is necessary.
BioWIN & buffer-tank-combination?
![Page 61: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/61.jpg)
Wärme in Perfektion.www.windhager.com
small base (only 0,75 m2)
all components are available from the front
almost arrangable to the wall
small height (only 1,89 m)
separable for delivery (narrow locations, stairs, ...)
fitts in almost every baesment!
BioWIN perfect for reconstruction
![Page 62: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/62.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – Pellets-Central-Heating-System
Overview:
1. Boiler types
2. Assembly and Function
3. Handling
4. Cleaning
5. Pellets-storage & -feeding
6. Planning
7. Systems
![Page 63: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/63.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN – System-solution
![Page 64: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/64.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN & AquaWIN
![Page 65: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/65.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN & solar, AquaWIN and CaloWIN classic
![Page 66: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/66.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN & solar, CaloWIN premium
![Page 67: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/67.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN & SilvaWIN, AquaWIN
![Page 68: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/68.jpg)
Wärme in Perfektion.www.windhager.com
BioWIN & solar, CaloWIN premium
![Page 69: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/69.jpg)
Wärme in Perfektion.www.windhager.com
Support rate till 1 time/year:
The burner-bowl is cleaned automatically by the patented burner-bowl-ash-discharge, the heating-surface is also automatic cleaned and two conveyor-screws transport all the ash automatically to the integrated ash box.
BioWIN – the strong facts
All informations on the full-text-display switchboard InfoWIN:
After activating the InfoWIN the BioWIN starts with a selve-control – controlling each sensor, switch, motor, .... On the switchboard InfoWIN all informations can be selected on the full-text-display.
24 „custom made“ - solutions
3 classes comforts x 4 sizes of output x 2 controls = 24 different boiler-solutions.
![Page 70: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/70.jpg)
Wärme in Perfektion.www.windhager.com
Fuly automatic pellets-feeding-unit
Patented & awarded pneumatic system with change-over-unit and 3 seperated suction-probes in closed circuit
BioWIN – the strong facts
Space-saving in new buildings & reconstruction:
The small design of the BioWIN is perfect for both:
new buildings (low-energy-houses, pre-fabricated-houses)
older houses (reconstruction or restoration)
Systems: ideal for combinations and always expandeble:
The BioWIN can be combinated with e.g.: tanks, solar, 2nd boiler. Also upgradings for more heating-circuits are possible with the control-system MES.
![Page 71: Welcome to Windhager Zentralheizung GmbH. Wärme in Perfektion. BioWIN – Pellets-Central-Heating-System The new Pellets-Comfort Output:](https://reader035.vdocument.in/reader035/viewer/2022062313/56649c9c5503460f9495a60c/html5/thumbnails/71.jpg)
Thank you very muchThank you very much
for Your attention!for Your attention!