winterwarm - chauffageindustriel-soper.be · acr 20 2-3,5 m 100-250 mm acr 28 2-4,5 m 100-250 mm t...

4
Winterwarm ACR air curtains Winterwarm presents the ACR-series: air curtains with an indirect fired unit air heater as heating unit. The ACR keeps the warmth inside and the cold outside! . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Winterwarm heating solutions Characteristics of the Winterwarm ACR-series Creates a comfortable climate inside Indirect fired unit air heater as heating unit Modern design Simple to install Maintenance friendly Energy saving Winterwarm-ACR brochure EN_Univ.-Brochuredef-204175 09-03-11 08:49 Pagina 2

Upload: others

Post on 18-Jan-2020

1 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Winterwarm - chauffageindustriel-soper.be · ACR 20 2-3,5 m 100-250 mm ACR 28 2-4,5 m 100-250 mm t opview b t mview frontview 2000 ACR20 -290 ACR28 -540 MultiTherm S (art.nr. IX.3911)

Winterwarm ACR air curtainsWinterwarm presents the ACR-series: air curtains with an indirect fired unit air heater as heating unit.

The ACR keeps the warmth inside and the cold outside!

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . .

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Winterwarm

heating solutions

h

Characteristics of theWinterwarm ACR-series

• Creates a comfortable climate inside

• Indirect fired unit air heater as heating unit

• Modern design• Simple to install• Maintenance friendly• Energy saving

Winterwarm-ACR brochure EN_Univ.-Brochuredef-204175 09-03-11 08:49 Pagina 2

Page 2: Winterwarm - chauffageindustriel-soper.be · ACR 20 2-3,5 m 100-250 mm ACR 28 2-4,5 m 100-250 mm t opview b t mview frontview 2000 ACR20 -290 ACR28 -540 MultiTherm S (art.nr. IX.3911)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

An inviting entrance determinesthe first impression of a company.Whether it is a shop, a hotel or ahospital: customers, guests or patients want to feel welcome. An air curtain above your entrancecan help achieve this for you.

Comfortable

With an air curtain, doors can remain

open, inviting people inside. The cur-

tain of air invisibly separates the

inside from the outside. The inner

climate is preserved while no draughts

and hardly any temperature changes

arise. Additionally, dust, exhaust

gases and other outside odours are

literally kept outside the door. Also, in

the summer, the heat does not enter

as quickly as it would without the air

curtain.

Indirect fired unit air heater

As a specialist in unit air heating,

Winterwarm introduces an air curtain

in which the heating unit is an

indirect fired unit air heater.

This combination offers several

advantages over electrical air curtains

or air curtains which are connected

to a water heated system:

• gas fired is cheaper than electrical

• no expensive central heating

system required

• simple installation

• no frost danger

• efficient energy consumption

(no pipe losses)

• produces heat within one minute

Functional

The Winterwarm air curtains are

available in 2 types: ACR 20 (19.7

kW) and ACR 28 (27.7 kW) which are

suitable for doors of max. 3.5 m and

4.5 m height respectively; both types

having a width of 2 m. The box at the

front of the unit air heater contains 4

fans with 1 motor. These provide a

strong vertical air current. The ACR

has a modern design with a neutral

colour suitable for every interior. This

is especially important in public

rooms. However, the ACR is also very

suitable for industrial applications

such as over cargo platforms: the

heater starts to operate as soon as the

roller door goes up. A major advanta-

ge of the indirect gas fired heater is

that the unit produces heat very

quickly.

DDV 80/125 – art.nr. IA.8202 CT 80/125 – art.nr. IA.8113

Winterwarm-ACR brochure EN_Univ.-Brochuredef-204175 09-03-11 08:49 Pagina 3

Page 3: Winterwarm - chauffageindustriel-soper.be · ACR 20 2-3,5 m 100-250 mm ACR 28 2-4,5 m 100-250 mm t opview b t mview frontview 2000 ACR20 -290 ACR28 -540 MultiTherm S (art.nr. IX.3911)

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Another application of the ACR is over

a passage between e.g. a heated

production hall and an unheated

warehouse. When an ACR is located

over the passage, the temperature in

the production hall remains fairly

constant and there is no draught from

the warehouse, while fork lift trucks

still have free passage.

Control and suspension

The control of the ACR can take place

by means of a digital modulating room

thermostat (MultiTherm S) which can

also be applied as a 3 stages-switch.

On the lowest setting the heater

produces about 60% of both its

heating capacity and air output.

A second option is the digital modula-

ting clock thermostat MultiTherm C.

Additionally, it is possible to connect

the ACR to a building management

system by means of an interface

(0-10V; optionally). There is a moun-

ting rail on top of the ACR to allow

easy installation by suspension from

the ceiling with threaded bar.

A

B

1000

763

450

630

ACR20 -1117ACR28 -1040

A BACR 20 2-3,5 m 100-250 mmACR 28 2-4,5 m 100-250 mm

topview bottomview

frontview

2000

ACR20 -290ACR28 -540

MultiTherm S (art.nr. IX.3911)

MultiTherm C(art.nr. IX.3912)

Applications ACR air curtains:

• shops

• hotels/restaurants

• shopping malls

• warehouses

• banks

• shopping passages

• cargo platforms, etc.

Winterwarm-ACR brochure EN_Univ.-Brochuredef-204175 09-03-11 08:49 Pagina 4

Page 4: Winterwarm - chauffageindustriel-soper.be · ACR 20 2-3,5 m 100-250 mm ACR 28 2-4,5 m 100-250 mm t opview b t mview frontview 2000 ACR20 -290 ACR28 -540 MultiTherm S (art.nr. IX.3911)

Winterwarm: leadingWinterwarm has been engaged in the development, production and sales of industrial heating in Europe since 1936.

The company not only specialises in indirect fired unit air heaters, but also sells radiant tubes,

rooftops, water heaters and destratification fans.

. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Famous Winterwarm-quality

• 75 years of experience• ISO 9001-2000 certified• Quick delivery• Reliable

Technical data

Type ACR 20 ACR 28

Article no. GT20A0WW GT28A0WW

Nominal heat input max. kW 21.5 30.0

Nominal heat input min. kW 14.5 20.5

Nominal heat output max. kW 19.7 27.7

Nominal heat output min. kW 12.8 18.3

Air output max. m3/h 3000 4000

Electrical supply Vac 230 230

Power consumption max. W 400 700

Current consumption A 1.7 3.0

Gas connection G” 1/2” 1/2”

Dimensions flue terminal concentric mm 80/125 80/125

Maximum suspension height (from bottom air curtain) m 3.5 4.5

Minimum suspension height (from bottom air curtain) m 2.0 2.0

Weight kg 120 140

Natural gas G20 II2E3P, II2ELL3P, II2ELwLs3P, II2Er3P, I2E(S)B, II2H3P, I3P

Max. gas consumption G20* m3/h 2.3 3.2

Winterwarm

heating solutions

h

Winterwarm BVIndustrieweg 8 Winterswijk The NetherlandsP.O.Box 36 NL-7100 AA Winterswijk The NetherlandsTel. +31 (0)543 54 63 00 Fax +31 (0)543 54 63 10www.winterwarm.nl [email protected]

Winterwarm UK Ltd. Unit H3, Taylor Business Park, Warrington Road, Risley, Warrington, Cheshire WA3 6BLTel. +44 (0)870 90 89 906 Fax +44 (0)192 57 62 996 www.winterwarmuk.com [email protected]

Winterwarm-ACR brochure EN_Univ.-Brochuredef-204175 09-03-11 08:49 Pagina 1