WL 850 HVTechnical Manual

Page 2: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

2

WL850 HV Technical Manual - Version 1, November 2007

3

Index

Introduction 5Operational Information 6Creating Carbonated Water 10Components Layout Diagram 12Pre Delivery Inspection Procedures (PDI) 14Installation Procedures 16Operating Instructions 20Maintenance And Servicing 22Sanitizing The Machine 24Cleaning WL 850 HV 25Troubleshooting The WL 850 HV 26WL 850 HV Exploded Diagram 28WL 850 HV Wetted Parts Diagram 30WL 850 HV Main Parts Layout Diagram 33WL 850 HV Electrical Wiring Diagrams 34Technical Specifications 36

Page 3: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

4

WL850 HV Technical Manual - Version 1, November 2007

5

Thank you for purchasing the Waterlogic WL850HV water purifier.The WL850HV is suitable for use in a small or large office and it is designed to beconnected to mains public drinking water supplies.Waterlogic International are using proven technology to clean and then purify your mains water supply and then chill the water so that you can enjoy great tasting and healthy still and sparkling water all the time.Waterlogic uses a unique filtration system containing activated carbon to remove chlorine and other chemicals from your water supply as well as sediment that have not been removed by your water authority.The water is then stored in a double cold tank assembly with choice of cold and sparkling and also a hot tank providing in total 5.5 litres of stored purified water. The cold tank contains a specially designed ultra violet light that destroys bacteria and protects the water from bacteria build-up while in storage.The WL850HV has been designed in a way that enables ease of service by your nominated supplier to change both the filter and the UV lamp at 6-month service intervals.The WL850HV has new design for the bottle fill solution.With over 10 years experience in the water industry Waterlogic International Ltd. is continually developing new products to meet the needs, and health concerns of businesses and the general public.If you would like Waterlogic International to keep you informed of the latest developments in the water industry go to our website at www.waterlogic.com and register for our free newsletter.

Introduction

Page 4: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

6

WL850 HV Technical Manual - Version 1, November 2007

77

Operational Information

WL850 HV moving of the small switch will allow just the hot button to be pushed to vend ambient water. This option does allow you to convert the machine for one button operation for hot water. All machines are factory set at two-button operation for hot water. Any change of the button configuration for use in hot water dispensing is the responsibility of the distributor if so required. Waterlogic strongly advises against the use of a one button operation for a hot water. The PCB also has a UV failure alarm, and timer switches that can set the UV lamp on time as 3 minutes, 10 minutes or constant.

COLD TANKThe cold tank is manufactured from 304 Stainless Steel which is non-corrosive, inert and reflects Ultra Violet Light (UV). The tank system consists of a double tank assembly. The cold water temperature should be set at 5ºC, this being ideal temperature for a cold drink. The capacity of the tank is two litres. When the water is stored in the Cold Tank it is chilled and exposed to UV at the same time, this protects the water from Bacteria growth.

UV LAMPThe UV light is an 8watt germicidal lamp at a wavelength of 253.7 NM, which is very efficient at destroying Bacteria found in water. UV radiation kills Bacteria by destroying the DNA nucleus of Bacteria. An 8-watt lamp is at peak performance for six months and then should be changed. Tests prove that the 8-Watt lamp in combination with a 2 litre stainless tank has a very effective kill rate of Bacteria. The lamp is immersed in the cold tank and protected by a quartz sleeve which allows UV radiation to pass through to the water. When the lamp is changed the quartz sleeve should be removed and cleaned also.The UV lamp can be set to 3 minutes, 10 minutes and constant time on the PCB.

The WL850HV is available in following options:a) Cold, Hot & Sparklingb) Cold, Ambient & Sparklingc) Cold & Sparkling

When reading this manual, note the differences between theoptions and focus on the particular sections that concern the unit installed.

WL3 Technical Manual - Version 1, October 2012

PCBThe PCB controls the solenoid valves, the pump level probe, the LED power and warning light. There is also a small switch mounted on the back of the PCB that will change the function of the hot button. On a hot and cold machine, the hot and sparkling button must be pushed together for hot water. But on an ambient machine

Page 5: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

8

WL850 HV Technical Manual - Version 1, November 2007

9

WATER PIPE AND FITTINGSAll water connection fittings are made by the John Guest Company and are approved to NSF standard 51. The machine is connected the water supply by a ¼” female bulkhead fitting.The entire internal water circuit and all the components which come in contact with water are food grade NSF / WRAS approved.

PLASTIC PANELSThe moulded panels are made from ABS plastic. All the ABS plastic panels are UV resistant and incorporate the heat retardant standards of CE and UL... Please note that the machine should not be exposed to direct sunlight. Placing machines in direct sunlight from a window, or close to a radiator, or on in a room of high ambient temperature will effect the efficiency of the refrigeration circuit.

WATER PUMPThe pump is 24V DC and forces the pre-chilled cold still water in to carbonation tank at high pressure. This pressure is required to overcome the internal carbonation tank pressure of 45 PSI of CO2 gas. By forcing cold water at pressure into a tank of CO2 gas the machine produces carbonated water. A level probe in the carbonation tank controls the water pump connected to the machine PCB.

THE GAS REGULATORThe correct flow and pressure of gas that is fed to the carbonation tank is controlled by a CO2 gas regulator and is factory set at 45PSI. The gas pressure can be increased and this may see an increase in the level of carbonation, but this is also relevant to water temperature and pressure. Over adjustment of gas pressure (50PSI) will see no increase of carbonation levels and in fact will stop the machine functioning correctly. Food grade CO2 gas must be used at all times.

FILTERSThe filtration system on the WL850HV is NSF approved two –stage filter. Stage one is a 10 micron screen; Stage two is a Granular Activated Carbon (GAC) process which will remove a whole range of contaminates e.g. chlorine, pesticides, sediment, and any taste or odour that may be in the water. Carbon filter also remove a whole range of other contaminants found in water. It is important for the UV sterilization system to be supplied with clean water in order to achieve maximum efficiency. If the water is not cleaned of particulate matter, this will restrict the penetration of the UV radiation into water. There are many kinds of different filter combinations available from Waterlogic to suit local water conditions, and for the exclusion of Crypto, Cysts and heavy metals. All filters must be changed at 6-month service interval.

HOT TANK The hot water tank has a two litre capacity; it is manufactured from 304 stainless steel and is heated by a 800 watt heating element. Temperature of the Hot Tank is controlled by a mechanical thermostat and is factory set at 87ºC, this being the ideal temperature for instant drinks. A thermal cut out is fitted to the Hot Tank to prevent overheating. The tank can be fitted with an optional scale-inhibiting filter to increase the tank life. Setting the hot water temperature at 87 ºC also helps stop scale forming in the Hot Tank.

COMPRESSORThe compressor operates at 220-240V and at 50Hz. It uses R134a non-Ozone depleting refrigerant gas. There is also the option to use Natural refrigeration gas

WATER VALVESDispensing of water to the customer is achieved by means of a 24V DC electrical solenoid valve. The valves are energized every time a customer pushes the dispense button for a drink. DC voltage is used to give a positive and quieter action of the solenoid valve. The WL850HV model is fitted with both inlet and outlet valves.

Page 6: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

10

WL850 HV Technical Manual - Version 1, November 2007

11

Creating Carbonated Water

CARBONATIONThe carbonation in the tank has been designed to a similar level to that in international soft drinks.Good carbonation depends on a combination of CO2 gas pressure, water pressure, water quality and temperature.

CREATING CARBONATED WATERUnderstanding how it works.Carbonated water is created by mixing carbon dioxide gas with water in a stainless steel chamber and is controlled by the following parameters:1. Temperature. The colder the water, the more the gas can be absorbed2. Water pumping pressure 75 PSI (4.8bar)3. CO2 gas pressure 45 psi (3bar)Water is pumped into the chamber in the form of a jet which strikes the plate at the bottom of the tank causing turbulence which in turn causes the gas to be rapidly absorbed into the water.

Page 7: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

12

WL850 HV Technical Manual - Version 1, November 2007

13

Components Layout DiagramHot and Cold

1

14151617

3456789

1011

1213

229282726 30

3132

33

34

1819202122

232425

Page 8: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

14

WL850 HV Technical Manual - Version 1, November 2007

15

Pre Delivery Inspection Procedures (PDI)

CAUTION:Only competent trained technicians should work on Waterlogic products.Waterlogic units may weigh over 25KG. We recommend caution when lifting.Packing materials could present a trip hazard. Keep them off the floor.Take care not to allow the power lead to get wet. If the lead gets wet it must not be used.CO2 gas cylinders used for sparkling units are under high pressure and should be handled carefully and all safety instructions should be followed.For Hot and Cold units, omit section 8, 10, 12.For Cold and Sparkling units, omit section 13, 15.

1. Unpack and carry out a visual inspection of the unit for any transit damage.

2. Remove the top cover and the lower front panel and visually inspect the internals

of the machine for any wires or pipes that may have come loose in transit.

3. Connect the water supply.

4. Ensure the switch on the rear of the machine is in the off position

and connect the unit to a power supply.

5. Connect CO2.

6. The unit is now live and suitable safety precautions should be taken.

7. Flush water through the hot tank first until the water runs clear of any carbon fines. Approximately 15 litres.

8. Now flush water through the cold tank. Approximately 5 litres. (20 litres if cold only)

9. Once you are sure that water is running through both the cooling and heating circuit

then turn on the heat and compressor switch at the rear of the machine.

10. Carry out a visual inspection for any water leaks.

11. The hot water will heat to approx 87ºC.

12. To test the cold water wait until the compressor has shut off. Extract a further 500 ml of water and allow the compressor to recover again. Test the 2nd cup of water taken. It should be between 3 and 7ºC.

13. Inspect the cold water produced for clarity and taste. If required flush more water to remove any adverse taste or carbon fines.

14. Return the switch to the off position and isolate the power and water to the machine.

15. Drain the hot tank and cold tank.

16. Replace all panels, clean the machine and repack the machine.

Pre Delivery Inspection Procedures (PDI)

Page 9: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

16

WL850 HV Technical Manual - Version 1, November 2007

17

Installation Procedures

Important notice: This procedure should only be carried out by an engineer or staff trained by Waterlogic International or an approved distributing agent.

1. Site the machine with a 50mm. air gap at both sides and back. Mount the machine

on a firm flat surface so that it cannot topple over.

2. Level the machine using the adjustable feet.

3. It is advisable that the water supply and electrical supply is within 2 Meters of the

machine.

4. Remove the top cover of the machine. If you are installing a freestanding machine also remove the lower front cover. This is retained by two clips located under the front edge at the bottom of the cover, push clips up to release.

5. Before connecting the CO2 bottle to the machine prepare the gas bottle by removing the dust cover (if fitted). Now face the gas outlet away from you and momentarily turn the gas on and off by twisting the knob located on the gas bottle. This will allow a high pressure burst of CO2 gas to clean any dust and dirt from the fittings. Now attach the gas regulator to the bottle and the gas pipe to the push fitting on the regulator. The pressure of the regulator should be set at 45PSI. Locate the gas bottle inside the machine and strap the gas bottle to the holder and turn on the gas. On mini machines, the gas will be located on the outside of the machine.

6. Make the water connection to the water supply pipe using an installation kit, turn on the water supply and flush the pipe until water supply runs clear of any dirt; then make the water connection to rear of the machine. Ensure that the water supply is turned on. The minimum working pressure is 30PSI/2 bar. The ideal pressure is 42 PSI/3bar.

7. Check the electrical socket, and then make the electrical connection to the machine, plugging the power lead into the rear of the machine, then connecting to the electrical socket. Make sure that the red and green switches located at the rear of the machine are off before connecting the electrical supply to the machine. Do not at this stage turn on these switches.

8. The water temperature of the machine is factory set at 5ºC for still/cold water and

87ºC for hot water. Sparkling water will automatically be colder than the still water as the cold tank system is designed to do this. It is possible to adjust the still water warmer or colder. It is advised not to adjust the cold water temperature as this could result in the cold tank freezing, or impairing the quality of the sparkling water.

9. Purge CO2 gas through the carbonation tank by lifting the yellow lever on the relief valve located on top of the carbonation tank for a few seconds.

10. Turn on the Red Power switch at the rear of the machine.

11. Flush 10 litres of water through the hot tank. To do so, depress the hot water button at the same time as the sparkling button, if installing a hot & cold machine. The first few litres of water through the machine may have a dark appearance. This is due to a small amount of carbon being released from the water filter when they are new. It is harmless and will disappear very quickly whilst you flush the machine.

12. Now depress the cold water button, this will flush water through the still cold tanks. Flush 5 litres. The sparkling water tank will automatically fill.

13. Check the machine for any water leaks or gas leaks.

14. Once you are satisfied that water is passing through both the hot and cold tank successfully then turn on the green heater compressor switch. The machine will now start to heat and chill.

15. The hot water will heat rapidly but it will take about approximately 40 minutes before the cold temperature reaches its set point.

16. When the machine has reached the target temperature the compressor will stop running. The temperature will continue to drop, as any ice that has formed on the sides of the tanks will start to melt and equalize the tank temperature.

17. To measure the water temperatures, please ensure that an accurate previously calibrated thermometer is available.

18. Once the machine has reached the correct temperatures then please ensures that the cold still and sparkling water produced tastes good. A plastic taste indicates that the machine needs to be flushed again.

Page 10: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

18

WL850 HV Technical Manual - Version 1, November 2007

19

19. The sparkling water quality is dependent on the water temperature, and the water/gas pressure. If the sparkling water is not sharp enough at first, then completely purge the sparkling tank of water by holding the dark blue button until no more water comes out of the machine and it starts blowing gas.

Stop pushing the dark blue button and allow the tank to automatically refill and chill down again. If you do need to make the water colder then please adjust the thermostat mounted on the rear of the machine in small movements clockwise. Over adjustment of the thermostat will cause the cold tank to freeze. If you need to increase the gas pressure then turn the screw adjuster clockwise on the gas regulator to do this and observe the needle position on the pressure indicator dial change. The regulator is factory set at 45 PSI. Adjustment of the gas pressure over 50 PSI could impair the quality of the sparkling water and stop the correct function of the machine.

20. If required by local health and safety guidelines test the machine to make sure it is electrically safe.

INSTALLATION KIT• Not supp lied with the machine• 2 meters of ¼” water pipe• PRV (pressure reducing valve) set at 3 bar or 42 psi• Non return valve (It is advisable to use a non-return valve on all carbonation units connected to a water supply)• Self-cutting sadd le valve or isolating valves (Check local water authority requirements)• CO 2 Gas• Allow 1 Hour

Page 11: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

20

WL850 HV Technical Manual - Version 1, November 2007

21

Operating the machine is very simple. It’s as simple as selecting the option you want, and press the dispense button.

THE MACHINE WILL DISPENSE FRESH WATER AT yOUR DISPOSAL.1. Green LED indicates the power is ON. Flashing red LED indicates no water/pump time out. If LED flashes green then orange this indicates a UV fault.

2. Push button 2 to select still water.

3. Push button 3 and then button 4 to dispense hot water.

4. Push button 4 to select sparkling water.

5. Dispense nozzle.

6. Drip tray.

Operating Instructions

1

3

5

6

24

Page 12: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

22

WL850 HV Technical Manual - Version 1, November 2007

23

Maintenance and Servicing1. Every six months it is strongly recommended that the filters and UV lamp be changed. If the model of machine is hot and cold, the hot tank may require any build up of Calcium to be removed. The need to remove calcium from the hot tank depends on local water conditions and the flow of water from the hot tank being restricted.

2. To carry out the service you will need to switch off the red and the green switch at the back of the machine and remove the machine top cover and lower front cover, if the machine is free standing.

3. Remember there is no need to turn off the water with a Waterlogic Twist Filter; the water is automatically isolated when you remove the filter.

4. The filter is located on the lower part of a freestanding machine behind the lower front cover. On a mini machine the filter is under the top cover. Remove the filter by gripping the filter head and twisting the filter body by hand clockwise (left-hand thread).

5. Replace with a new Twist Filter.

6. Make sure you turn off the red switch at the back of the machine to isolate the electrical power.

7. Remove the UV lamp by unplugging the UV loom connector and pulling the lamp upward, then unscrewing the UV retaining nut located on the top shelf of both models, and remove the Quartz Sleeve from the cold tank. Clean the Quartz Sleeve and remove any surface lime scale that may have adhered to the sleeve surface. Check the black O Ring for signs of perishing and change if necessary.

8. Fit the Quartz Sleeve back into the cold tank taking great care at this stage not to crack the Quartz Sleeve by over tightening the UV retaining nut.

9. Inspect the UV loom if it shows signs of discolouration or wear, replace it. Assemble the UV loom onto a new UV lamp and fit into the quartz sleeve. Do not touch the UV lamp.

10. Inspect the blue faucet nipple and if it is cracked or has Calcium build up, replace it. Please ensure that you use cleaning gloves when handling parts that come in direct contact with the water.

11. Clean the Condenser Grill and Compressor of any dirt build up.

12. Check the air gap around the machine is not blocked.

13. Turn on the power supply and make sure only the red switch on the rear of the machine in the on position.

14. Flush five litres of hot water (if a hot & cold machine), 5 litres of cold water and one litre of carbonated water through the machine to ensure that the filters are generated and the water is running clear of any carbon fines.

15. Purge the CO2 gas by lifting the yellow pressure release lever for 3 seconds.

16. Make sure that the UV lamp is alight by observing a blue glow from the top of the UV cap. Do not remove the lamp from holder whilst ignited and do not look into a naked UV light.

17. Inspect the water and electrical connections visually.

18. Turn on the green switch and allow the machine to cool and heat the water.

19. Check the machine is clean and functions to the customer’s satisfaction.

PARTS REqUIRED FOR 6-MONTH SERVICE• Waterlogic Twist Filter• UV Lamp• UV Loom (Only replace if required on visual inspection)• Cleaning Materials• De-Scaler Non Toxic (Hot & Cold models only)• Allow 45 minu tes

Notes: Only trained personnel should repair and service a Waterlogic 850.To sanitise or de-scale a machine with a Waterlogic twist filter it is necessary to mix a solution of either de-scaler or sanitizer in a dummy filter cartridge to flush it into the machine. Please ensure no de-scaler enters the cold or sparkling tanks. Sanitizer and de-scaler must be flushed into the system down stream of any Carbon filter installation, otherwise the filter will remove the sanitizer or de-scaler being used.Waterlogic recommend the use of sterilizing solution, vending machine surface cleaner, and Bacterial Wipes. Please do not use any abrasive or cream surface cleaners.

Page 13: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

24

WL850 HV Technical Manual - Version 1, November 2007

25

SANITISING THE MACHINE1. You will need to have an Ametek filter housing to follow this procedure. Also sanitizer, disposable rubber gloves, and bacterial wipes or spray.

2. Mix a solution of sanitizer in the Ametek filter housing.

3. Turn off the water supply to the machine and release the internal water pressure by depressing the dispense button momentarily and remove the water supply pipe.

4. Isolate the power to the machine.

5. Bypass the internal twist filter to avoid mixing sanitizing solution with the active carbon.

6. Connect the outlet of the Ametek housing to the inlet of the machine and connect supply water pipe to the inlet of the Ametek housing.

7. Turn on the power and water supply to the machine.

8. Depress the blue dispense button until the sanitation fluid starts to flow out of the faucet nipple.

9. Allow the sanitation fluid to stand in the machine for 20 minutes.

10. Do not let any sanitation fluid enter the hot tank.

11. Then flush the cold water until the water runs clear of sanitizer.

12. Again isolate the water to the machine and release any internal water pressure now isolate the power.

13. If this procedure is being done in conjunction with the 6 monthly services then change the filter.

14. Remove the Ametek filter housing from the back of the machine and re-connect the water supply pipe to the back of the machine. Reconnect the filter.

15. Turn on the power and water flush the machine until the water runs clear.

16. Visually inspect water connections for any leaks.

17. Remove the faucet nipple and inspect to see if there are any cracks or scratches or lime-scale build up on the nipple, if so then replace it. If the faucet nipple is OK then sterilise it and put back using clean rubber gloves.

18. Remove and clean the drip tray, and grill. If the grill is damaged or heavily stained and you are unable to clean it then it is advisable to replace the grill.

19. Wipe all surfaces around the drip tray and faucet nipple area with a bacterial wipe or spray.

20. Return the drip tray to position.

21. Flush a further 15 litres of water if you have changed the filter and ensure there are no carbon fines and all sanitation fluid has been removed from the water system.

22. All personnel should be aware of the company requirements for their own personal health and hygiene.

23. Test for taste before leaving and ensure that the water quality of the machine is adequate.

CLEANING WL850HV1. It is recommended to clean the machine at least once per week. The cleaning cycle may be required more often depending on the amount of use of the machine and the surrounding environment.

2. Turn off the power at the wall socket and remove the power cord at the rear of the machine.

3. Please wear clean rubber gloves to carry out the cleaning functions.

4. Remove the top cover and replace the blue faucet nipple. Clean and soak the removed nipple in sterilizing solution ready for the next cleaning cycle. Discard any faucet nipples that are cracked, or split. Be careful not to drip water on the PCB.

5. Remove and clean the drip tray assembly.

6. Clean all machine surfaces with non-abrasive vending machine cleaner/sanitizer.

7. Replace the drip tray.

8. Wipe the faucet nipple and all plastic surfaces with an anti Bacterial Wipe.

9. Re-connect the machine and turn on the power and check for correct operation.

PARTS REqUIRED TO CLEAN A MACHINE• Rubber Gloves.• Paper Towel.• Surface Cleaner.• Blue Faucet Nipple.• Bacterial Wipes.• A Replacement drip tray/grill if required.• Allow 15 minutes.

Page 14: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

26

WL850 HV Technical Manual - Version 1, November 2007

27

TROUBLESHOOTING THE WL850HV1. No Cold Water Flowing: There are a number of reasons that could be causing this problem. 1) Check if the water in the building is turned off! 2) Check if the isolating valve has been turned off! 3) Check if the filter blocked with sediments or passed its change date! 4) Check if the solenoid valves are operating! 5) Check if the cold tank has frozen. 6) Check if the red LED warning light is flashing!

2. Water Flows but is Not Cold: 1) Check that the compressor switch at the rear of the machine is turned on. 2) Have you just taken more than 3 jugs of water? The machine takes about 30 min to recover temperature after heave use. 3) Is the machine sited in an area with an ambient room temperature in excess of 30°C. 4) Does the machine have a 5cm air gap around it? 5) Test the machine cooling system for loose of refrigeration gas. If the compressor is continually running hot and mot making cold water, then this could mean it need gas. Check the compressor to ensure it is running. Make sure the thermostat is adjusted correctly.

3. Water has a Plastic or Funny Taste: 1) If the machine is new it may need to be flushed. 2) Has the machine been unused over a long weekend? Then flush 5 litres of water before using. 3) Fit a new filter if it has passed its changing date. 4) Contact you local dealer if adverse local water conditions are causing taste problems.

4. Restricted or Slow flow of cold or sparkling water: 1) Check that the water supply is above 1.5 bar or 21 PSI, as the machine will not function correctly below this! 2) Check that the gas bottle is not empty. 3) Check that the filter is not blocked or past its changing date. 4) Check that the faucet is not blocked.

5. Vend buttons sticking: 1) this fault is caused by dirt or cleaning material filling the gap around the button. Do not use cream or abrasive surface cleaner.

6. Red LED Warning Light flashing: 1) the pump has been running too long and has timed out. Please check the water supply to the pump. Te reset the pump turn the power on and off to the machine.

7. Machine no Power: 1) check that the machine switches are on the back of the machine. 2) Isolate the power supply and check the machine fuse. 3) Check that the power cord is plugged into the back of the machine and is pushed home. 4) Check that the power cord is plugged into the wall socket and is switched on. 5) Check that there is no problem with the building electrical supply.

8. No Hot Water: 1) Make sure the heater switch is on at the rear of the machine. 2) Does the hot tank need to be de-scaled? 3) Check the power supply to the heating element. 4) Disconnect the power and check the resistance of the heating element. 5) Is the water supply to the machine turned on? 6) Are the solenoid valves operating correctly? 7) Is the filter blocked or past its change by date?

9. Factory sets the cold water at 5°C. Waterlogic strongly advice that you do not adjust the water to a colder temperature. Care should be taken if the thermostat is adjusted colder as this could increase the risk of the cold tank freezing. It is advised that any adjustment to the thermostat to male the water colder be done in small turns of the thermostat of a few degrees at a time. Allow the compressor to cycle on and off, check that the temperature is as required before any further adjustment. In the event that the cold tank should freeze then please turn the compressor switch mounted at the rear of the machine to the off position. Allow the machine to stand for one hour. Flush 1 litre of water through the machine, adjust the thermostat back to the factory position set point as marked and turn the compressor switch back on.

WL850 HV Technical Manual - Version 1, November 2007

26 27

Page 15: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

28

WL850 HV Technical Manual - Version 1, November 2007

29

Exploded Diagram

50 3237

333436

30

35

22

3940414243

4431

10

1214

13

15

2425272829

4511

46

47

23

26

4818

38

19

2120

16

17

9

67

8

1

4

3

2

5

Replacement Parts List

Page 16: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

30

WL850 HV Technical Manual - Version 1, November 2007

31

Wetted Parts Diagram

12

3

5

6

7

8

9

10

1112

14

29

39

41

4543

5354

44

47

46

484950

5251

42

58596061

63

62

40

56

57

55

38

36

30

3337

3235

34

3164

15

20

24

2526

27

28

23

21

19

16

17

182213

4

Page 17: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

32

WL850 HV Technical Manual - Version 1, November 2007

33

Main Parts Layout Diagram

DRAINVALVE

SOLENOIDVALVE

SOLENOIDVALVE

FILTERDRYER

HOTTANK

COMPRESSOR

CONDENSER

FILT

ER

IN (Water)

SOLENOIDVALVE

WAT

ER IN

SPARKLING WATER OUT

SOLENOIDVALVE

PUMPCHECKVALVE

CO2 In

SPARKLINGTANK

SAFETYVALVE

COLDSENSOR

COLDTANK

SUCK BACK

SOLENOIDVALVE

CHECK VALVE

HOT WATER OUTHOT WATER OUT

AIR VENT

SOLENOIDVALVE

SOLENOIDVALVE

Page 18: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

34

WL850 HV Technical Manual - Version 1, November 2007

35

Electrical Wiring DiagramCold, Ambient and Sparkling

Electrical Wiring Diagram Cold, Hot and Sparkling

DANGER HIGH VOLTAGES PRESENT ON THIS PCBCARE MUST BE TAKEN WHEN LIVE TESTING

DANGER HIGH VOLTAGES PRESENT ON THIS PCBCARE MUST BE TAKEN WHEN LIVE TESTING

Page 19: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

36

WL850 HV Technical Manual - Version 1, November 2007

37

Description WL850 HV HCS

WL850 HVCS

WL850 HV MHCS

WL850 MCS

Width Depth Height

38W-34D-114H (CM)

38W-34D-114H (CM) 38W-34D-47H 38W-34D-47H

Water Connection Dia ¼” Dia ¼” Dia ¼” Dia ¼”

Cold Water Temp 5-8ºC 5-8ºC 5-8ºC 5-8ºC

Hot Water Temp 85-87ºC 85-87ºC 85-87ºC 85-87ºCWeight 40Kg 38Kg 29Kg 28KgPower Supply 230Volt/50Hz 230Volt/50Hz 230Volt/50Hz 230Volt/50HzCompressor 140W 140W 140W 140WHeater 800W 800W 800W 800WPump 35W 35W 35W 35W

Technical Specifications

WL850 HV Technical Manual - Version 1, November 2007

36 37

Page 20: WL 850HV technical manual - Waterlogic · connected to mains public drinking water supplies. ... The PCB also has a UV failure alarm, ... The entire internal water circuit and all

38

EN

G02

79-2

5/0

2/1

3

WLI Trading Ltd.Suite 4, 2nd Floor Beacon Court, Sandyford, Dublin 18, Ireland

www.waterlogic.com

Waterlogic USA, 4141 N. 156th Street, Omaha, NE 68116

Speak to a Water Expert Rest of the world

[email protected] + 353 1 293 1960

USA, Canada and Mexico

[email protected] + 1 402 884 7212