PX-iP GatewayOperating Manual
EN2
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 3
EN
The original version of this instruction has been prepared in German in accordance with DIN EN 82079-1.
1 Notes on the operating manual
We are glad that you have chosen our product and we would like to thank you for your trust!This operating manual contains infor-mation and instructions for safe installa-tion, commissioning, setup and mainte-nance, as well as proper operation of the PX-iP gateway.The operating manual is intended to in-crease the reliability and life cycle, and to help avoid hazards and downtime, or a loss of warranty claims. It is absolutely necessary that the operating manual is read and understood.For a better readability, the PX-iP gateway is hereinafter referred to as "gateway" or "device" and the smoke alarm device with radio link is referred to as "smoke alarm device".1.1 Scope of operating manualThe operating manual only applies for the gateway.
1.2 Applicable documentsThe gateway is used in combination with the manufacturer's smoke alarm devices with radio link (e.g., PX-1C). In addition to this operating manual, also observe: • The Quick Reference Guide
provided with the device • The operating manual for
the smoke alarm device • FAQ for the web app under
the menu item "Help/FAQ"The operating manual of the PX-iP gate-way is not provided in printed form with the device. The current version of this manual is available at: pyrexx.com/en/support/download
f Print out the operating manual in colour if possible.
Content
1 Notes on the operating manual 32 Safety instructions 93 Overview 144 Commissioning and setting up 165 Reset 246 Installation variants 267 Messages 298 Troubleshooting 339 Maintenance 4410 Decommissioning 4511 Accessories, spare parts and service 4612 Glossary 4613Technicalspecifications 4714 Alarm and alert tones 49
EN4
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 5
1.3 Name plate and identifi cationThe name plate of the gateway can be found on the underside of the device.
Fig. 1 Name plate (sample, information can deviate)
1.4 CE conformityPyrexx Technologies GmbH declares that the PX-iP gateway is compliant with the fundamental requirements and other rele-vant provisions of the following directives:
• Low Voltage Directive 2014/35/EU • EMC Directive 2014/30/EU • R&TTE Directive 2014/53/EU • Environmentally compatible design for
energy-related products 2009/125/EC • Waste Electrical and Electronic Equip-
ment Directive (disposal) 2012/19/EU • Restriction on the use of certain haz-
ardous substances in electrical and electronic equipment 2011/65/EU
in accordance with: • EN 301 489-1 V1.9.2 • EN 55022 • EN 300 220 V2.4.1
(receiver category: 2)The CE Declaration of Conformity is available from the manufacturer under the following reference number: k_76680
1.5 Safekeeping of the operating manual
The operating manual is an important component of the gateway and must al-ways be kept at hand near the installation location.1.6 Symbols usedVarious markings and symbols are used in the text in the operating manual.These are explained below.
Warning symbol in warning labels
Additional information and guidelines
(1) Numbered action steps f Symbol for an instruction or a
required action 5 Result of an action
4 Problem associated with an action • Symbol for a list
Light signal of the signal LED
Length of the signal tone or interval
Volume of a signal tone
Back
Edit
Delete
Main menu
EN6
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 7
1.7 CopyrightAll rights are reserved, particularly the rights of duplication, distribution and translation. No par t of this operating manual may be reproduced in any form, or processed, duplicated, or disseminated using electronic systems without written permission of Pyrexx Technologies GmbH.1.8 Limited warrantyWhen used and serviced as intended, Pyrexx Technologies GmbH warrants a de-fect-free device only for the original purchas-er of this product that was purchased either from Pyrexx Technologies GmbH directly, or through an authorized reseller, for a period of 12 years from the date of purchase. The limited warranty is not transferable and does not apply to buyers who have purchased the device from a reseller who is not au-thorized by Pyrexx Technologies GmbH. This also applies for online auctions, but is not limited thereto. Rights arising from stat-utory regulations remain unaffected by the limited warranty.
f Please keep your receipt as proof that the device has been purchased from Pyrexx Technologies GmbH or from an authorized dealer, and as a proof of purchase date.
This receipt is mandatory for any warranty claims! The limited warranty will be grant-ed only if the device is used in accordance with the operating manual. The limited warranty does not cover claims resulting from accidents, misuse, application errors, negligence, or the warranty exclusion cri-teria described below.1.9 Warranty exclusion criteria
Physical/mechanical damageIf the device has been damaged, e.g., the housing has been broken or the device has been opened, any warranty claim shall be forfeited. The same shall apply to subjecting the device to any form of force, which does not cause physical damage to the device, but does cause damage inside the housing (e.g., the electronics).
ContaminationIf the device is externally and/or internal-ly contaminated by adhering substances (excessively contaminated), any warranty claim shall be forfeited. Paint and similar substances on the surface of the device and within the housing of the device shall be considered as contamination.Moisture damage/corrosionIf the device, and in particular its electron-ics, are damaged by moisture of any kind, any warranty claim shall be forfeited. Thus moistureisnotonlytheexposuretofluid,but also regular, above-average exposure of the device to humidity (> 70 %). Liquids and high humidity can damage the elec-tronics of the device by causing corrosion.Thermal damageIf the device has been exposed temporari-ly or continuously to a temperature below 0 °C or above 70 °C, any warranty claim shall be forfeited.
Excessive rechargeable battery loadThe device's rechargeable battery is used for emergency power supply (e.g., during a power failure) and it can be recharged a limited number of times. Excessive device operation via this rechargeable battery and premature consumption of the limit-ed number of charge cycles can cause any warranty claim to be forfeited.Observe with the following before sub-mitting a warranty claim:
f Check if at least one of the aforementioned warranty exclusion reasons is present.
f Bear in mind also that there are sufficienttechnicalcapabilitiestodetermine, when submitting a warranty claim, whether the device has really been used as intended, and therefore if the warranty claim isjustifiedorunjustified.
Pyrexx Technologies GmbH expressly re-serves the right to charge a person who makes a warranty claim although at least
EN8
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 9
one of the aforementioned warranty ex-clusion reasons is present, for the costs associated with the necessary technical examination of the facts!1.10 DisclaimerExcept for the limited warranty described herein, Pyrexx Technologies GmbH as-sumes no additional explicit or implicit liability under the applicable statutory pro-visions. This shall also extend to any liability in relation to tradability and/or suitability for a particular purpose under any implied liability which nevertheless exists under the law; the after-sales services shall be limited to the duration of this warranty.
1.11 Limitation of liabilityYour rights are limited to the repair or replacement of this device as shipped. Pyrexx Technologies GmbH shall accept no liability for any special, incidental or consequential damages, including, but not limited to, resulting loss of revenue, loss of profits,restrictionsoftheuseofsoftware/hardware, loss or recovery of data, cost of substitute equipment, downtime, damage to property and claims by third parties as a result of contractual, statutory or tort recovery claims arising out of warranty, regardless of any other warranty, limited or implied by the law, or in the event that the limited warranty shall not apply, the liability of Pyrexx Technologies GmbH shall be limited to the purchase price of the device.
2 Safety instructions
• Use for smoke alarm devices in private households and small, commercially used areas with typically occurring frequency of smoke alarms
Note the following when using the gateway:
f Only use the device with the power unit and power cable provided
f Use the device only as intended and in a technically perfect condition
2.3 Unintended useThe device must not be used for the fol-lowing purposes: • Communication with smoke alarm
devices from another manufacturer • Firealarmsystemasspecified
in EN 54 and DIN 14675
2.1 Representation and display of warning labels
The warning labels are action-oriented; they are structured and graded as follows:
CAUTIONType and source of the risk!Explanation about the type and source.
f Measures to prevent the risk.
CAUTIONPotential minor injuries, material or environmental damage.
2.2 Intended useThe gateway is designed for the follow-ing purposes: • Communication with the
manufacturer's smoke alarm devices (e.g., PX-1C) and relaying information (e.g., smoke alarm) to the user via the Internet
EN10
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 11
• Testing of the alarm function by intentionally triggering alarms in excess of the afore-mentioned frequencies. If there are more than 3 smoke alarms per year, thiscanblockthenotificationfunction of the gateway
• Monitoring rooms with foreseeable regular/frequently occurring smoke development
• Any use that is not expressly described as permitted in this operating manualExceptions to the above require a wr itten agreement with the manufacturer.
2.4 General safety informationThe general safety information describes all measures to ensure safety thematically and applies at all times.General informationNeither the gateway nor the smoke alarm devices connected to it directly transmit analarmtoanofficialentitythatcanpro-videhelp (firebrigade).Thegateway issubject to strict quality controls during production. In addition, a function test is performed before delivery. Nevertheless, unexpected malfunctions can occur. The manufacturer is not responsible for timely forwarding of an alarm and accordingly accepts no liability if an alarm is not or forwarded or not promptly forwarded to the user (e.g., failure of the Internet connection).Data securityThe device can communicate with smoke alarm devices and report information (e.g., smoke alarm) to the user via the Internet.
Relative to data security, the manufacturer warrants the following: • Your gateway sends data via the
Internet with strong encryption and an individual key
• Personal data is treated with strict confidentialitybyPyrexxDataGmbH
• All information concerning residen-tial addresses, as well as positions of smoke alarm devices, is optional
• Forwarding of alarms to systems of third party providers is only possible if you make these settings yourself
• The web app does not process any data concerning the position of your smartphone, the gateway or the smoke alarm device
• On request, Pyrexx customer support will delete your data from its IT system
Replacing the rechargeable batteryUnder some circumstances you must re-place the rechargeable battery, e.g., if the provided rechargeable battery is defective or if the charge cycles have been used up.
CAUTIONDanger of explosion if the re-chargeable battery is not replaced properly!The battery can explode or ignite due to improper replacement of the rechargeable battery. This can result in chemical burns and other burn injuries.
f Only use the type of rechargea-ble battery recommended by the manufacturer (see chapter 13 „Technicalspecifications“onpage 47)
f Observe the instructions "Re-placing the rechargeable battery" in the FAQ
EN12
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 13
External influencesExternalinfluencescancausemalfunctionsand damage to the device as well as the rechargeable battery.Protect the device from: • Moisture • Cold • Direct sunlight and excessive heat
(damage to the rechargeable battery) • Dustandfinedust • Spiders and insect infestation • Grease • Nicotine and paint fumes • Paintfinishes(e.g.,wallpaint) • Adhesives • Contamination of any kind
Immersion in waterImmersion in water can damage the device.
f Do not immerse the device in waterOpening the deviceThe device is a closed system. Any tam-pering with the device, in addition to the loss of the limited warranty and statutory warranties, also means that the device cannot and must not be used as intended.
f Do not open the deviceException:
f Seechapter“Replacingtherechargeablebattery“onpage11
Sensitive componentsThe dev ice cons i s ts o f sens i t ive components.
f Do not throw the device f Do not let the device fall f Do not exert any pressure on the
device
EN14
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 15
3 Overview
3.1 Function
Fig. 2
1
2
3
4
Mode of operation
1 Internet2 Server3 Web app4 "Apartment" with gateway, smoke
alarm device and router
Basic functionsThe basic functions of the device are: • Sending warnings (e.g., smoke alarm)
of the connected smoke alarm devices, to the user via SMS or email
• Read-out and analysis of measured data of the connected smoke alarm devices
NotificationIntheeventofafirealarm,thegatewaycanrelayanotificationviaSMSoremail.In the web app you can specify who receives the alarm (see chapter 4.11 “Notification“onpage22).The gateway itself does not generate any alarm signal.3.2 ControlsThe gateway is controlled via buttons with signal LEDs. You must be able to see the light signals, even when the buttons are activated.
IMPORTANT: Only press the buttons to the point that you feel a resistance, and keep them pressed in that position.
2 3 4 51
Fig. 3 Gateway controls
1 Battery compartment2 Radio button (A) with signal LED3 Gateway button (B) with signal LED4 Port for power unit5 LAN port
Battery compartmentThe installed energy reserve (rechargea-ble battery) is used as to protect the gate-way from failure during an interruption of the power supply (e.g., power outage). In this case the energy supply is assured over a period of at least 2 hours.When power supply via the grid connec-tion is restored, the rechargeable battery will be recharged.
Radio button (A)The radio button (A) is used to set up and delete radio connections between gateway and smoke alarm devices.Gateway button (B)The gateway button (B) has 3 functions: • Mute in battery mode • Switch-off after unplugging the
power cable on the device • Resetting the connection
settings to the router
EN16
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 17
Signal LEDsThe signal LEDs in the radio button (A) and gateway button (B) show status messages (e.g., at commissioning and set-up).Connection for the power unitThe mains connection is used for the energy supply of the gateway via power unit and power cable. By plugging in and unplugging the power cable on the device you switch the gateway on or off (see chapter4.13“Switchingoffthegateway“on page 24).
By unplugging the power unit from electrical outlet, you bring the gateway into battery operation.
LAN connectionThe LAN connection connects the gateway to the router via the LAN cable. It is strictly required for the installation.
4 Commissioning and setting up
The Operating Manual describes initial installation of the gateway in combina-tion with smoke alarm devices from the web app.
f It is essential that you follow the action steps in the order given for a successful installation
f For other installation types, e. g. installation of the gateway in an existing radio group, see chapter 6 „Installationvariants“onpage26
f Observe the notes in the web app f Only use the power unit and power
cable included in the shipping package
f Removetheprotectivefilmfromthe plug and gateway
4.1 Requirements for commissioning
Prior to commissioning, ensure the follow-ing at the installation location: • Internet connection • Router with LAN port
• LAN or WI-FI connection • For WI-FI:
WLAN-SSID (WI-FI name), password and encryption type must be available
• At least one PX-1C smoke alarm device • Gateway in default state
(seechapter5.1“Gatewayreset“ on page 24)
• End device for web app operation: smartphone, tablet or PC with Internet browser
4.2 Opening the web app
f Open the web app in the browser at www.pyrexx.com/app
4.3 Registering as a userIf you do not have access to the web app yet,setupyouruseraccountfirst.(1) Enter the registration details
f In the web app's start-up screen, click "Register"
f Enter your email address and choose a passwordThe email address will be your user name.
f Fornotification,seechapter4.11“Notification“onpage22
f Check the "I accept the terms and conditions of use" check box
f Click "Complete registration"(2) Confirmtheregistrationprocessin
the email 5 Registration successful
4.4 Log-in
(1) In the start-up screen, enter user name and password
(2) Click "Log in" 5 Web app log-in successful
5 Empty device list appears
EN18
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 19
4.5 Adding a gateway
(1) Click "Add a device"(2) Assign the gateway to a room(3) Enter the serial number on the
name plate of your gateway 5 "Gateway" is shown as the type and
"Pyrexx" as the manufacturer(4) Entertheverificationcodeonthe
name plate of your gateway(5) Click "Save"
5 Gateway icon appears in the device list
4.6 Gateway setup
(1) Click the gateway(2) Click "Radio group" title, then click
"Gateway functions" button 5 You are now in the "Gateway
functions" menu(3) Set up gateway
f Click "Set up the gateway" and observe notes
f Click "Continue"(4) Even if you want to set up a WI-FI
connection, connect the gateway to the router using a LAN cable
(5) Select LAN or WI-FI connectionFor a more stable installation, we recommend the LAN connection.
f For a WI-FI connection enter the WI-FI parameters and click "Save"
4.7 Connecting the gateway
(1) Connect plug with power cable and plug into power outlet
(2) Connect power cable with gateway(3) As soon as the signal LED of the
gatewaybutton(B)startsflashingclick "Establish connection"
5 Message: "The connection attempt is running. This process can take up to 3 minutes."
While the gateway is starting up the LEDs of the gateway button (B) and the radio button (A) become active in that order:
Gateway starts:
(B)Gateway parameter query:
(B)Normal operation:
(B) 5 Gateway is connected with the
routerRadio group query:
(A)(A)
5 No radio group found in learning mode
5 Message: "The connection attempt was successful"
(4) Click "Installation complete" 5 You are in the room sketch
4.8 Creating a radio group with gateway and smoke alarm devices
The connection between smoke alarm devices and the gateway is set up di-rectly on the devices (learning mode).
(1) For a WI-FI connection now re-move the LAN cable and bring the gateway to the planned installation site
(2) Press radio button (A) on the gateway until signal LED is on, then release:
(A)Star ting learning mode on the gateway:
(A)(A)
(A)
EN20
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 21
5 Gateway is in the learning mode for 10 minutes max.
Adding a smoke alarm device to a radio group
IMPORTANT:a) Do not activate any smoke alarm device until it is at the intended installation location.b) Ensure a minimum distance of 3 m to the other smoke alarm devices and the gateway.
1
2
4
3
5
7
6
Fig. 4 Smoke alarm device controls
1 Split pin (activation backup)2 Activation button3 Magnetic carrier4 Signal LED5 Radio button6 Smoke intake lamellaes7 Test/Stop button
(smoke alarm device cover)
(1) Remove split pin at the red activation button of the smoke alarm device
(2) PushactivationbuttonflushShort acoustic signal
Starting learning mode on the smoke alarm device:
5 Radio group in learning mode for another 10 minutes
(3) Switch all other smoke alarm devic-es into learning mode as described
(4) Finalise radio group f Brieflypressflashingradiobutton(A)
on the gateway until light goes off 5 Radio group is in operation
5 No device in the radio group is flashing
4.9 Network scan
(1) Click the gateway icon(2) Click "Radio group" title, then click
"Gateway functions" button(3) Click "Scan network"
5 Message: "Network scan in progress"(4) Wait until network scan has
completed(5) Click "Network scan complete"
4 In the case of an error see chap-ter7.7“Connectiontosmokealarmdevicelost“onpage30
(6) Click "Gateway functions" title, then click "Radio group" button
5 You are now in the "Radio group" menu
EN22
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 23
Assigning smoke alarm devices to rooms
f Assign each smoke alarm device the correct room
5 Smoke alarm devices have been assigned to the rooms
4.10 Test signal and measured data
(1) Click to go back to the room sketch menu
(2) Click the gateway icon(3) Click "Radio group" title, then click
"Gateway functions" button(4) Click "Trigger test signal"
5 Message:“Testsignalinprogress”
Short acoustic signal from all installed smoke alarm devices
(5) Click "Test signal complete"
(6) To view the measured data of a smoke alarm device, click the smoke alarm device in the "Radio group" menu
(7) Click "Maintenance" title, then click "Measured data" button
5 Measured data of the smoke alarm device is displayed
4.11 Notifi cationFor the following events the web app sends notificationstotheuserviaemailorSMS: • Smoke alarm:
In addition, to the email, an SMS can also be sent (see FAQ)
• Malfunction (see chapter 8 “Troubleshooting“onpage33)
• Test requirement for smoke alarm devices and maintenance reminder
Allnotificationsarealwayssenttotheus-er who created the apartment in the web app. The email address and mobile phone number can be changed in the web app (see FAQ).
For apartments that are self-created you can set-up a different app user who will be informed in the event of alarm or malfunction.Proceedasfollowstodefinethis user :(1) Register the new user as user in the
webapp(seechapter4.3“Register-ingasauser“onpage17)
(2) Register with your user name(3) Select the desired apartment
(4) Top right click 5 "Apartment" menu opens
(5) Enter user name of the new user in the"User"field
(6) Click "Save" 5 Theuserwillbenotifiedinthe
future(7) Relay user data to the new user
Under his user account, the user can enter an email address and the mobile phone number of his choice. After changing the password, this data is only visible to the user.
Inordertoviewthenotificationsofthe smoke alarm device, enter it in the "Apartment" menu.
4.12 GSM alarming
If there is a connection fault to the router, the gateway can send a smoke alarm, as long as GSM reception is available.
Check GSM reception at the gateway location, toensurerelayofnotificationseven if the WI-FI or LAN connection is interrupted. Proceed as follows:(1) With a smartphone, check whether
GSM reception exists at the installa-tion site of the gateway
(2) Change the location of the gateway if necessary
EN24
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 25
4.13 Switching off the gatewayTo switch off the gateway without re-setting the gateway or the radio settings, proceed as follows:(1) Remove power cable on gateway
Cyclic acoustic signal on the gateway for 30 seconds
(2) Wait 30 secondsor(3) Brieflypressgatewaybutton(B)
5 Gateway is switched off
5 With a delay of 10 minutes you will get the message "Connection to PX-iP lost"When you reconnect the power cable, the gateway is placed in service again. You will receive an email stating "Gateway is again reachable".
5 Reset
In some situations you must execute a reset to restore the default state, e.g., for new installation of the radio group after a move.5.1 Gateway resetPrior to the reset, the gateway must be connected to the power supply.(1) Start reset
f Remove power cable on the gateway
Cyclic acoustic signal on the gateway for 30 seconds
(B)During this time, the following steps must be performed in that sequence:
(2) Reset radio module f Press radio button (A) on the gate-wayuntilitflashes,thenrelease
(A)
(A)Signal LED of radio button (A) "Off"
(3) Reset network f Press gateway button (B) until a long
acoustic signal is emitted, then release
(B) 5 Gateway is switched off
5.2 Smoke alarm device resetIn order to re-create the radio group after the gateway reset, also reset the smoke alarm devices. (1) Pull out activation button(2) Press and hold Test/Stop button for
2 to 3 seconds
Sof t t i ck ing for about 2 seconds
(3) Press radio button with splint pin untilitflashes,thenrelease
5 The device is in its default state
EN26
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 27
6 Installation variants
6.1 Large dwelling unitsWith each new apar tment, by default the web app creates 6 typical living areas. For large dwelling units (e.g., kindergar-tens, dormitories) we recommend add-ing all rooms in the web app beforehand (see FAQ).6.2 Scanning in the serial numbersWith the Android and iOS app, when in-stalling the smoke alarm devices you can scan in the serial number of each device from the name plate (see FAQ) and allo-cate it to the respective room. The gate-way takes this allocation into account with the network scan.6.3 Shared radio groups and
subgroupsThe gateway supports radio networks with shared radio groups and subgroups (see operating manual of the smoke alarm devices). It is always installed as a mem-ber of the shared radio group so that it is connected with all smoke alarm devices.
Extension of the radio networkThe radio network can be retroactively ex-tended with smoke alarm devices (see oper-ating manual for smoke alarm devices). These changes become visible through a network scan in the web app.6.4 Installation of the gateway in
an existing radio groupTo do this you must extend the radio group. In this regard observe the following:(1) Observe the installation steps in
chapter4.1“Requirementsforcom-missioning“onpage16uptoandincludingchapter4.7“Connectingthegateway“onpage18
(2) Bring the existing radio group (shared radio group) into learning mode
f Press and hold the radio button with splint pin on any smoke alarm device of the radio group, until:
All signal LEDs "Off"
f Release radio button
5 Device max. 10 minutes in learning mode
(3) Add additional devices f Seechapter4.7“Connectingthegateway“onpage18
(4) Connect plug with power cable and plug into power outlet
(5) Connect power cable to gateway
(B)(6) Immediately click "Establish
connection" 5 Message: "The connection attempt
is running. This process can take up to 3 minutes."
While the gateway is starting up the LEDs of the gateway button (B) and the radio button (A) are active.
Gateway starts:
(B)Gateway parameter query:
(B)Normal operation:
(B) 5 Gateway is connected to the router
Radio group query: (A)
(A) 5 After start, the radio button (A) on thegatewayflasheslikethesignalLED of the smoke alarm device.
EN28
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 29
(7) Finalise radio group f Brieflypressradiobutton(A)on
the gateway until the light goes off 5 Radio group gateway is in operation
No device in the radio group isflashing
(8) Observe the installation steps in chapter4.7“Connectingthegateway“on page 18
6.5 Changing the connection to the router
After installation you can also select be-tween LAN connection to the router and WI-FI connection to the router.
IMPORTANT:To ensure that the radio group remains intact, DO NOT execute radio module reset.
(1) Remove power cable on the gateway
(2) Only execute the network reset (seechapter5.1“Gatewayreset“on page 24)
(3) Set up gateway (see chapter 4.6 “Gatewaysetup“onpage18)
5 Router connection is changedA network scan (see chapter 4.9 “Networkscan“onpage21)isnot required, however to be certain, it should be executed.
7 Messages
7.1 Smoke alarmA smoke alarm is sent via email, and SMS if desired. In the web app it is possible to flexiblyspecifywhowillbenotified(seechapter11“Notification“onpage22).While a smoke alarm is active, the web app shows the development of the temperature values in the dwelling unit (see FAQ).
f In every case, clarify and eliminate the cause of the smoke alarm
7.2 Smoke alarm has endedYou get this message if the conditions for a smoke alarm are no longer present.7.3 Connection to gateway lostYou get the fault message as soon as the regular signals of the gateway are not received for 10 minutes. Possible causes aredescribed inchapter8.6“Error inaradiofunction(gatewayreachability)“onpage 39.
7.4 Connection to gateway restored
You get this message, when after loss of connection(seechapter7.3“Connectionto gateway lost“onpage29)normaloperation is restored.
7.5 Gateway in battery operationYou get this message if the power to the power unit is interrupted. In this case there is an emergency supply via the re-chargeable battery for a period of approx. 2 hours. All functions of the gateway remain avail-able in battery operation.
4 Gateway goes into battery operationRegular signal over 1 minute on the gateway
4 Gatewaybutton(B)flashesaslongas battery operation continues
(B)
EN30
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 31
Possible causes: • Gateway power plug unplugged • Power outage • Power unit or cable defective
Remedy: f Restore the power supply within
2 hours or replace rechargeable battery (see FAQ)
f Replace power unit or cable if necessary
7.6 Gateway in network operation again
You get this message, when after battery operation(seechapter7.5“Gateway inbatteryoperation“onpage29)of thegateway the grid power supply is restored.
7.7 Connection to smoke alarm device lost
Connection problems to smoke alarm devices are detected individ-ually with the aid of a network scan (seechapter4.9“Networkscan“onpage 21).
4 If the connection to a smoke alarm device is interrupted, you will get an email within the automatic test interval.
Possible causes: • Installation location of an
existing smoke alarm device has been changed
• Smoke alarm devices that have been added have been mounted too far away from, or too close to existing smoke alarm devices
• Thefirstinstallationwasfaulty,this is especially possible for installations without gateway
• Other sources of radio interference impair the radio communication
• Smoke alarm devices are defective or switched off
Remedy: f Seechapter8.7“Errorinaradio
function (smoke alarm device reachability)“onpage42
7.8 Maintenance reminderWhen the last maintenance of the smoke alarm device of an apartment is 11 months in the past, a reminder is sent to the person who created the dwell-ing unit. This message will be repeated monthly until the executed maintenance has been documented in the web app.7.9 Status of the smoke alarm devicesWithin the automatic test interval the gateway reads out the status of the smoke alarm devices. The result is sent per email to the user of the web app (see FAQ for information on the adjustment possibilities).
This status message alerts the user when at least one of the smoke alarm devices provides measured data that soon there-after will result in acoustic fault messages (battery status, contamination).Regardless of the above, the reminder message concerning the maintenance oc-curs in accordance with DIN 14676.
EN32
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 33
Example of a status message via email
Web app: 3 devices to test
Dear Mr Neumann,Smoke alarm devices with radio link that you maintain will soon generate acoustic fault alarms (due to the battery condition or the amount of contamination, see chapter 7 "Fault and error messages" in the operating manual of the smoke alarm device with radio link).
The list of these devices can be found in the web app under menu item "Devices with need for testing".
IMPORTANT: Please note that, due to technical reasons, it is possible that there might be transmission errors of the measured data and, in addition, that there are other reasons which might make maintenance necessary. For example, this is the case when one of the above mentioned alarm devices is no longer in its intended installation location or if it is painted over during renovation work.
Best regards,Your Pyrexx team
8 Troubleshooting
Problems during commissioning and set-up are indicated by error messages in the web app and LED signals on the devices.Faults during operation are communicated through appropriate messages (see chap-ter7“Messages“onpage29).8.1 Commissioning in the wrong
sequence
4 Gateway cannot connect to the Internet
4 Network scan cannot be executed
4 Maintenance data cannot be read outPossible causes: • Gatewaywasnotaddedfirstinthe
web app • The prerequisite for network scan
is that the gateway must be correctly connected
• Maintenance data will only be read out if a network scan was executed beforehand
Remedy: f Place the gateway in service again
and pay attention to the sequence of installation steps (see chapter 4 “Commissioningandsettingup“onpage 16)
8.2 Error when adding the gateway
4 Gateway cannot be created in the web app
Invalid serial number or verification code
• Serialnumberorverificationcode entered incorrectly
Remedy: f Check entry and correct if necessary
or f Use iOS or Android app to scan the
serial number from the QR code on the name plate
EN34
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 35
Gateway of another manufacturer
• Serial number belongs to a gateway of another manufacturer
Remedy: f Install the gateway with the app of
the third-party manufacturerGateway not in default state
• Gateway already installed at a different location
Remedy: f Delete other installation (see chap-ter5“Reset“onpage24)
f Contact customer support if neces-sary(seechapter11.2“Customersupport“onpage46)
8.3 Error when connecting the gateway
4 Gatewaybutton(B)flashesatregular intervals
(B)
4 A connection cannot be established
4 An error message appears in the web app
Possible causes: • No LAN connection or faulty
LAN connection • Router has no connection to the
Internet • WI-FI settings are not correct
or completeRemedy:(1) Return gateway to default state
(seechapter5.1“Gatewayreset“on page 24)
(2) Establish LAN connection between gateway and router (also for WI-FI installation!)
(3) Check whether the router actually has a connection to the Internet
f Use a smart phone or PC to call up a website via the router
(4) For a WI-FI connection, ensure that WLAN-SSID, password and encryp-tion type are correct
(5) Set up the gateway again (see chap-ter4.7“Connectingthegateway“on page 18)
(6) After establishing a WI-FI connec-tion the LAN cable can be removed
8.4 Smoke alarm device does not change to learning mode
4 No connection between smoke alarm device and a radio group
4 Radio button (A) is illuminated red
(A)Smoke alarm device incorrectly positioned
• Smoke alarm device is installed too close or too far away from other smoke alarm devices
Remedy:(1) Return smoke alarm device to de-
faultstate(seechapter5.2“Smokealarmdevicereset“onpage25)
(2) Correct the position of the smoke alarm device
(3) Activate smoke alarm device 5 Smoke alarm device in learning
mode
Radio group no longer in learning mode
• Learning mode will be switched off after 10 minutes
Remedy: f Return the radio group to learning mode(seechapter4.7“Connectingthegateway“onpage18)
5 Smoke alarm device in learning mode
EN36
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 37
5 Gateway in learning mode(A)
Smoke alarm device not in default state
• A reset was not executed on the smoke alarm device prior to activation
4 Radiobutton(A)isbrieflyilluminat-ed green
(A)Remedy:(1) Reset of the smoke alarm device in
question(seechapter5.2“Smokealarmdevicereset“onpage25)
(2) Reactivate smoke alarm deviceSmoke alarm device from another manufacturer
• Smoke alarm device is an identical type from a different manufacturer
Remedy: f Ensure that the manufacturer on
the name plate is identical for all devices of the radio group
Smoke alarm device is defectiveRemedy:(1) Check whether a different smoke
alarm device in the same position changes to learning mode
(2) Replace defective smoke alarm device
(3) Re-teach the replaced smoke alarm device(seechapter4.7“Connectingthegateway“onpage18)
8.5 Gateway does not change to learning mode
4 No connection between gateway and an existing radio group
4 Radio button (A) is illuminated red
(A)
Gateway is incorrectly positioned
• Gateway is installed too close or too far away from other smoke alarm devices
Remedy:(1) Execute reset of the radio module
in the gateway (see chapter 5.1 “Gatewayreset“onpage24)
(2) Correct the position of the gateway(3) Reconnect the gateway, with powerRadio group not in learning mode
4 Signal LEDs of the smoke alarm devicesarenolongerflashing
• Learning mode will be switched off after 10 minutes
Remedy: f Bring the radio group into learning mode(seechapter6.4“Installationof the gateway in an existing radio group“onpage26)
Maximum number of smoke alarm devices
• Radio group already contains the maximum number of smoke alarm devices
Remedy: f Reinstall radio group with a lower
number of smoke alarm devicesGateway not in default state
• Radio module in gateway was not in default state
4 Radiobutton(A)isbrieflyilluminat-ed green
(A)Remedy:(1) Execute reset of the radio module
in the gateway f Remove power cable on the
gateway Cyclic acoustic signal on the gateway for 30 seconds
EN38
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 39
(B)During this time, the following steps mustbeperformedinthespecifiedsequence:
f Press radio button (A) on the gate-wayuntilitflashes,thenrelease
(A)(A)
Signal LED of radio button (A) "Off"
(2) Return the radio group to learning mode(seechapter6.4“Installationof the gateway in an existing radio group“onpage26)
(3) Connect power cable to gatewayStart learning mode on the gateway:
(A)(A)
(A)
5 Gateway detects the radio group and is in learning mode for another 10 minutes
(4) Brieflypressradiobutton(A)onthe gateway
Signal LED of radio button (A) "Off"
5 Radio group is extended
Gateway is defectiveRemedy:(1) If it was possible to establish the
connection to the gateway, but the measures cited above do not func-tion, contact customer support (see chapter11.2“Customersupport“onpage46”)
(2) Replace defective gateway (see chapter4“Commissioningandsettingup“onpage16)
(3) Dispose of the old device (see chap-ter10.1“Disposal“onpage45)
8.6 Error in a radio function (gateway reachability)
4 An error message appears in the web app.
4 Procedure (network scan, test signal, firmwareupdate,readmaintenancedata) cannot be successfully con-cluded, because the gateway does not respond.
Gateway is switched off
4 Gateway is switched offSignal LED gateway button (B) "Off"
Possible causes: • Gateway has been switched off
intentionally (see chapter 4.13 “Switchingoffthegateway“ on page 24)
Remedy: f No additional measures are
required
Gateway damaged
• Gateway shows possible external damage(seechapter2.4“Generalsafetyinformation“onpage10)
Remedy:(1) Replace damaged gateway(2) Reinstallthechapter4“Com-
missioningandsettingup“onpage 16 replacement device accordingly
(3) Dispose of old device (see chap-ter10.1“Disposal“onpage45)
Gateway without grid power
4 Gateway is switched offSignal LED gateway button (B) "Off"
• Power outage • Network power plug is unplugged
and no emergency reserve (rechargeable battery of the gateway is dead or defective)
EN40
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 41
Remedy: f Restore power supply f Replace rechargeable battery if
necessary (see FAQ)Connection fault – IP network
4 Gatewaybutton(B)flashesatregular intervals
(B) • Internet outage • Router defective or without
grid powerRemedy:(1) With other devices, check whether
an Internet connection exists f Inform Internet provider if necessary
(2) Check Internet connection of the router
(3) Restore power supply(4) Restart router(5) Replace router if necessary (see FAQ)
WI-FI connection to the router is faulty
• WI-FI error, e.g., after a power outage or due to changed WI-FI settings
Remedy:(1) Checkconfigurationoftherouter(2) Set up gateway connection again
(seechapter4.6“Gatewaysetup“on page 18)
LAN connection to the router is faulty
4 Gatewaybutton(B)flashesatregular intervals
(B) • LAN cable not plugged in
correctly or defectiveRemedy:(1) Check plug connection of the LAN
cable(2) Check LAN cable and replace if
necessary
(3) Set up gateway connection again (seechapter4.6“Gatewaysetup“on page 18)
Gateway malfunction
4 Gateway malfunction, in spite of ex-cluding the possibility of interruption of communication or energy supply
• Network function fault • Gateway is defective
Remedy:(1) Switch off gateway (see chapter 4.13
“Switchingoffthegateway“onpage 24) and reconnect
(2) If the error persists, reset the net-work function
f Remove power cable on the gateway
Cyclic acoustic signal on the gateway for 30 seconds
(B)
f Press gateway button (B) until a longer acoustic signal is emitted, then release
(B) 5 Network function is reset
If the long tone does not sound, see chapter8.8“Erroratgatewayreset“on page 44.
f Reconnect gateway (see chapter 4.7 “Connectingthegateway“onpage 18)
(3) If the error persists, reset and re-in-itialize all smoke alarm devices and thegateway(seechapter5“Reset“on page 24)
(4) If the error persists, contact cus-tomer support (see chapter 11.2 “Customersupport“onpage46)
(5) If a solution cannot be found, during the warranty period, send defective gateway with purchase receipt back to the manufacturer
EN42
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 43
(6) Replace defective gateway (see chapter4“Commissioningandsettingup“onpage16)
(7) Dispose of old device (see chap-ter10.1”Disposal“onpage45)When the connection is functioning again, you will receive an email automatically (see chapter 7.4 “Connectiontogatewayrestored“on page 29).
• Gateway not reachableRemedy:(1) Ensure that the gateway is connect-
ed to the router (see chapter 7.3 “Connectiontogatewaylost“onpage 29)
(2) Repeat network scan (see chapter4.9“Networkscan“onpage 21)
8.7 Error in a radio function (smoke alarm device reachability)
4 Procedure (network scan, test signal, firmwareupdate,readmaintenancedata) is concluded with an error message
4 A wrong response or no response fromspecificsmokealarmdevicesor radio groups
Temporary radio fault
• Interference due to other radio-based devices
Remedy: f Repeat network scan (see chapter4.9“Networkscan“onpage 21)
Smoke alarm device switched offRemedy:(1) Switch on the smoke alarm device
(see operating manual for the smoke alarm devices)
(2) Repeat network scan (see chapter 4.9 “Networkscan“onpage21)
Smoke alarm device is defectiveRemedy:(1) Procure a replacement device(2) Bring the radio group into learning
mode and add replacement device (seechapter4.8“Creatingaradiogroup with gateway and smoke alarmdevices“onpage19)
or(1) Reset and set-up the radio group
again with replacement device(2) Repeat network scan (see chapter 4.9
“Networkscan“onpage21)(3) Dispose of old device (see chap-
ter10.1“Disposal“onpage45)Not with the smoke alarm device connected to the radio group
• A smoke alarm device has indeed been installed but not integrated in the radio group
Remedy:(1) Bring the radio group into learning
mode(2) Add smoke alarm devices(3) Repeat network scan (see
chapter4.9“Networkscan“onpage 21)
Smoke alarm device incorrectly positioned
• Excessiveorinsufficientdistancebetween smoke alarm devices
Remedy:(1) Reset all devices to default
state(seechapter5“Reset“onpage 24)
(2) Mount smoke alarm devices with the prescribed relative distance
(3) Reconnect gateway (see chap-ter4.7“Connectingthegateway“on page 18)
EN44
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 45
(4) Set up radio group again (see chapter4.6“Gatewaysetup“onpage 18)
(5) After each added smoke alarm device execute a network scan for verification(seechapter4.9“Net-workscan“onpage21)
8.8 Error at gateway reset
4 There is no long acoustic signal at network reset
Remedy:(1) Reconnect power cable(2) If necessary repeat gateway reset
several timesEnsure that you maintain the pressure point of the gateway button (B).
9 Maintenance
9.1 MaintenanceYou must perform visual and function tests at regular intervals.Software updateAs a rule the software of the gateway is updated at regular intervals (see FAQ).Visual inspection and function checkPerform a visual inspection once a month. Ensure that: • The Power cable and the power
unit are undamaged and connected • The router is undamaged
and connected • The radio button (A) on the
gateway is illuminated green • The gateway button (B) on the
gateway is illuminated green andflashesevery10seconds
CAUTIONReduced battery service life!Radio functions of the gateway, such as network scan or test signal, reduce the battery service life of the smoke alarm devices.
f Only execute the network scan at thespecifiedinterval(seeFAQ).
9.2 CleaningObserve the following when cleaning:
f Clean with care, e.g., with a damp cloth
f Do not press the radio button (A) or the gateway button (B) by mistake
10 Decommissioning
10.1 DisposalThis product should never be placed in domestic waste according to the German Electrical and Electronic Devices Act (ElektroG).
f Return the device to be disposed of to the manufacturer for further utilization, or hand it over to your local waste disposal company
f Note that improper dispos-al can harm the environment
EN46
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 47
11 Accessories, spare parts and service
11.1 Accessories and spare parts
• Power cable • Power unit • Spare rechargeable battery for
gateway (can be purchased from the manufacturer)
• Smoke alarm device with radio link PX-1C
11.2 Customer supportPyrexx Technologies GmbHSpichernstraße 210777 BerlinGermany
+49 30 8871 606 641
Customer suppor t can be reached via "Contact" in the login screen of the web app.
pyrexx.com/de/support
12 Glossary
Radio networkThe total number of shared radio groups and subgroups in the connection with a gateway.Learning modeIn this status, gateway and smoke alarm device "learn" which devices are members of a radio group.Network scanThe network scan scans all members of a radio network and allocates the devices to the gateway. In this process it reads-in the measured data of the connected smoke alarm device • Temperature • Contamination • Battery level • Smoke density • Signal strength
After the network scan, the measured da-ta is updated regularly and automatically.
13 Technical specifications
Prerequisite for operation Internet, WI-FI or LANUse With the manufacturer’s smoke alarm
device with radio link (e.g., PX-1C)Emergency power supply/duration 3.6 V NiMH AA-LSD-NTC, interchange-
able/at least 2 hoursPower supply 5 V, 1 A USB power supply unit32-bit processor 32-bit, SMD technologyOptimum storage temperature 5 to 35 °C, <70 % rel. humidityProtection class IP 40Colour Refrigerator whiteMaterial ABSDimensions (L x W x H) 10 x 10 x 3,6 cmWeight Approx. 210 g, netOperation Web appUpdate capability Via WI-FI and LAN
EN48
Operating Manual: PX-iP - Gateway Operating Manual: PX-iP - GatewayEN 49
Radio networking Frequency: 868.3 MHz in accordance with R&TTE Directive, ISM-band, WI-FI, GSM
Data encryption AES256Maximum number of networked nodes per group
15 (including PX-iP)
Maximum number of networked radio groups with PX-iP
15
Radio range 400 m (± 10 %) on open transmis-sionfield
14 Alarm and alert tones
Alarm or alert tones
Description Volume Interval length Interval
Alert tone – commissioning and setup
Power cable un-plugged fromgateway
/ 30 seconds
Network plug removed or power failure
60 seconds
Network resetsuccessful
No interval/
2 secondsLastly 1 second continuous tone
1 secondStart can take up to 2 minutes.
1 second continuous tone