xsp series - grainger industrial supply - mro products ... ref er to field adjustable output spec...
TRANSCRIPT
T (800) 236-6800 F (262) 504-5415US: www.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada
† See www.cree.com/lighting/products/warranty for warranty terms
Rev. Date: V4 10/01/2015
Product DescriptionDesigned from the ground up as a totally optimized LED street and area lighting system, the XSPSeries delivers incredible efficiency without sacrificing application performance. Beyond substantial energy savings and reduced maintenance, Cree achieves greater optical control with our NanoOptic® Precision Delivery Grid™ optic when compared to traditional cobra head luminaires. The XSP Series is the better alternative for traditional street and area lighting with quick payback and improved performance.Applications: Roadway, parking lots, walkways and general area spaces
Accessories
Field-Installed
Backlight Control ShieldXA-SP1BLS - Provides 1/2 mounting height cutoff
Bird SpikesXA-SP1BRDSPK
NanoOptic® Precision Delivery Grid™ optic
Made in the U.S.A. of U.S. and imported parts
CRI: Minimum 70 CRI
CCT: 4000K (+/- 300K); 5700K (+/- 500K)
Limited Warranty†: 10 years on luminaire/10 years on Colorfast DeltaGuard® finish
Performance Summary
XSP SeriesXSP1™ LED Street/Area Light – Single Module – Version B
Ordering InformationExample: BXSP-B-HT-2ME-A-40K-UL-BZ
BXSP B HT A
Product Version Mounting Optic Input Power Designator CCT Voltage Color
Options Options
BXSP B HTHorizontal Tenon
2ME*Type II Medium2LG*Type II Long3ME*Type III Medium4ME*Type IV Medium5METype V Medium 5SHType V Short
A53W
40K4000K57K5700K
ULUniversal 120-277V
BKBlackBZBronzeSVSilver
ML Multi-Level - Refer to ML spec sheet for details - High: 100%, Low : 26%
N Utility Label and NEMA® Photocell Receptacle - External wattage label per ANSI C136.15 - 7-pin receptacle per ANSI C136.41 - Factory connected 0-10V dim leads - Photocell and shorting cap by others - Includes Q9 option - Refer to Field Adjustable Output spec sheet for details
Q9 Field Adjustable Output - Refer to Field Adjustable Output spec sheet for details
R NEMA® Photocell Receptacle - 7-pin receptacle per ANSI C136.41 - Factory connected 0-10V dim leads - Photocell and shorting cap by others
* Available with Backlight Shield when ordered with field-installed accessory (see table above)NOTE: Price adder may apply depending on configuration
23.7"(601mm)
5.1"(129mm)
9.3"(237mm)
Multi-Level Sensor location(ordered as an option)
Shown with PT-1H Tenon
Shown with Type 5ME Optics
Weight
18 lbs. (8kg)
T (800) 236-6800 F (262) 504-5415US: www.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada
Product Specifications
CONSTRUCTION & MATERIALS• Die cast aluminum housing • Tool-less entry• Mounts on 1.25" (32mm) IP, 1.66" (42mm) O.D. or 2" (51mm) IP, 2.375" (60mm) O.D.
horizontal tenon (minimum 8" [203mm] in length) and is adjustable +/- 5˚ to allow for fixture leveling (includes two axis T-level to aid in leveling)
• Luminaire secured with two mounting bolts standard• Designed with 0-10V dimming capabilities. Controls by others• Exclusive Colorfast DeltaGuard® finish features an E-Coat epoxy primer with an
ultra-durable powder topcoat, providing excellent resistance to corrosion, ultraviolet degradation and abrasion. Black, bronze and silver are available
• Weight: 18 lbs. (8kg)
ELECTRICAL SYSTEM• Input Voltage: 120-277V, 50/60Hz• Power Factor : > 0.9 at full load• Total Harmonic Distortion: < 20% at full load• Class 2 driver• Integral 10kV surge suppression protection standard• To address inrush current, slow blow fuse or type C/D breaker should be used• 10V Source Current: 0.15mA
REGULATORY & VOLUNTARY QUALIFICATIONS• cULus Listed• Suitable for wet locations• Certified to ANSI C136.31-2001, 3G bridge and overpass vibration standards• Meets CALTrans 611 Vibration testing• 10kV surge suppression protection tested in accordance with IEEE/ANSI C62.41.2• Meets FCC Part 15 standards for conducted and radiated emissions • Luminaire and finish endurance tested to withstand 5,000 hours of elevated ambient
salt fog conditions as defined in ASTM Standard B 117• Meets Buy American requirements within ARRA• DLC qualified. Exceptions apply when N or Q9 (select adjustments) options are
ordered. Please refer to www.designlights.org/QPL for most current information• RoHS compliant. Consult factory for additional details• Dark Sky Friendly, IDA Approved. Please refer to www.darksky.org for most current
information
1 Lumen maintenance values at 25˚C (77˚F) are calculated per TM-21 based on LM-80 data and in-situ luminaire testing2 In accordance with IESNA TM-21-11, Projected Values represent interpolated value based on time durations that are within six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)3 In accordance with IESNA TM-21-11, Calculated Values represent time durations that exceed six times (6X) the IESNA LM-80-08 total test duration (in hours) for the device under testing ((DUT) i.e. the packaged LED chip)
Electrical Data*
Input PowerDesignator
System Watts120-277V
Total Current
120V 208V 240V 277V
A 53 0.44 0.25 0.22 0.20
XSP1™ LED Street/Area Luminaire – Single Module – Version B
* Electrical data at 25˚C (77˚F). Actual wattage may differ by +/- 10% when operating between 120-277V +/- 10%
Recommended XSP Series Version B Luminaire Lumen Maintenance Factors (LMF)1
Ambient Optic InitialLMF
25K hrProjected2
LMF
50K hrProjected2
LMF
75K hrProjected/Calculated2,3
LMF
100K hrCalculated3
LMF
5˚C(41˚F)
2ME, 2LG, 3ME, 4ME 1.04 1.02 1.01 1.00 0.99
5ME, 5SH 1.05 0.94 0.86 0.80 0.74
10˚C(50˚F)
2ME, 2LG, 3ME, 4ME 1.03 1.01 1.00 0.99 0.98
5ME, 5SH 1.04 0.93 0.86 0.79 0.73
15˚C(59˚F)
2ME, 2LG, 3ME, 4ME 1.02 1.00 0.99 0.98 0.97
5ME, 5SH 1.03 0.92 0.85 0.78 0.72
20˚C(68˚F)
2ME, 2LG, 3ME, 4ME 1.01 0.99 0.98 0.97 0.96
5ME, 5SH 1.01 0.90 0.83 0.77 0.71
25˚C(77˚F)
2ME, 2LG, 3ME, 4ME 1.00 0.98 0.97 0.96 0.95
5ME, 5SH 1.00 0.89 0.82 0.76 0.70
T (800) 236-6800 F (262) 504-5415US: www.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada
PhotometryAll published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Products/Outdoor/Streetlights/XSP-Series-Streetlight
XSP1™ LED Street/Area Luminaire – Single Module – Version B
RESTL Test Report #: PL06675-002BXSP-C-**-2ME-E-40K-UL w/XA-SP1BLSInitial Delivered Lumens: 7,078
1921
3843
5764
7686150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-2ME-A-40K-UL w/XA-SP1BLSMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 4,133Initial FC at grade
.1 .5
60˚
.21
80'
20'
20'
40'
6.1
0m
6.1
12.2
40'60' 20' 0' 20' 40' 60'
12.218.3 6.1 0m 6.1 12.2 18.3
80'
24.4 24.4
0'
40' 12.2
18.360'
Position of vertical planeof maximum candlepower.
CURB LINE
RESTL Test Report #: PL04512-001BXSP-B-**-2LG-A-40K-UL w/XA-SP1BLSInitial Delivered Lumens: 3,837
1869
3738
5607
7476150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-2LG-A-40K-UL w/XA-SP1BLSMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 3,784Initial FC at grade
80' 80'
20'
20'
40'
0m
6.1
6.1
12.2
12.2
40' 40'60' 60'20' 20'0'
12.218.3 6.1 0m 6.1 12.2 18.324.4 24.4
0'
40'
30.5 30.5 36.636.642.7 42.7
100' 100'120' 120'140' 140'
18.3
18.3
60'
24.4
24.4
80'
80'
60'
Position of vertical planeof maximum candlepower.
1
CURB LINE
.5
80˚
.2.1
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
Type II Long w/BLS Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings**
Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 3,784 B1 U0 G1 4,050 B1 U0 G1
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
2LG
RESTL Test Report #: PL04169-001BXSP-B-**-2LG-A-40K-ULInitial Delivered Lumens: 4,956
1913
3826
5739
7653150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-2LG-A-40K-ULMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 4,979Initial FC at grade
.2.1
80˚
1
80'
20'
20'
40'
6.1
0m
6.1
12.240'60' 20' 0' 20' 40' 60'
12.218.3 6.1 0m 6.1 12.2 18.3
80'
24.4 24.4
0'
40' 12.2
30.5 30.5
100' 100'
Position of vertical planeof maximum candlepower.
18.360'
.5
CURB LINE
Type II Long Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 4,979 B2 U0 G1 5,329 B2 U0 G1
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
Type II Medium w/BLS Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings**
Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 4,133 B1 U0 G1 4,592 B1 U0 G1
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
2ME
RESTL Test Report #: PL06675-001BXSP-C-**-2ME-E-40K-ULInitial Delivered Lumens: 8,850
1951
3902
5852
7803150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-2ME-A-40K-ULMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 4,806Initial FC at grade
1.1 .5
60˚
.2
80'
20'
20'
40'
6.1
0m
6.1
12.2
40'60' 20' 0' 20' 40' 60'
12.218.3 6.1 0m 6.1 12.2 18.3
80'
24.4 24.4
0'
40' 12.2
18.360'
Position of vertical planeof maximum candlepower.
CURB LINE
Type II Medium Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 4,806 B1 U0 G1 5,340 B1 U0 G1
T (800) 236-6800 F (262) 504-5415US: www.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada
PhotometryAll published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Products/Outdoor/Streetlights/XSP-Series-Streetlight
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
Type III Medium w/BLS Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings**
Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 4,085 B1 U0 G1 4,539 B1 U0 G1
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
3ME
RESTL Test Report #: PL04170-001BXSP-B-**-3ME-A-40K-ULInitial Delivered Lumens: 5,085
839
1678
2517
3356150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-3ME-A-40K-ULMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 4,806Initial FC at grade
1.1 .5
60˚
.2
80'
20'
20'
40'
6.1
0m
6.1
12.2
40'60' 20' 0' 20' 40' 60'
12.218.3 6.1 0m 6.1 12.2 18.3
80'
24.4 24.4
0'
40' 12.2
18.360'
Position of vertical planeof maximum candlepower.
CURB LINE
Type III Medium Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 4,806 B1 U0 G1 5,340 B1 U0 G1
XSP1™ LED Street/Area Luminaire – Single Module – Version B
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
Type IV Medium w/BLS Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings**
Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 3,983 B1 U0 G1 4,263 B1 U0 G1
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
4ME
RESTL Test Report #: PL04171-001BXSP-B-**-4ME-A-40K-ULInitial Delivered Lumens: 4,947
995
1990
2984
3979150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-4ME-A-40K-ULMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 4,979Initial FC at grade
0m6.1 18.312.218.3
18.3
0m0'
6.120'
6.120'
60'
24.480'
12.240'
12.240'
60'
40'
18.3
60' 20'
12.2
40'
6.1
20'0' 60'
24.4
80'
24.4
80'
.2
.1
Position of vertical planeof maximum candlepower.
45˚
1
.5
30.5100'
CURB LINE
Type IV Medium Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 4,979 B1 U0 G1 5,329 B2 U0 G1
RESTL Test Report #: PL04513-001BXSP-B-**-3ME-A-40K-UL w/XA-SP1BLSInitial Delivered Lumens: 4,272
816
2448
3265
1632
150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-3ME-A-40K-UL w/XA-SP1BLSMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 4,085Initial FC at grade
.5.2 1
45˚
.1
80'80'
20'
20'
40'
6.1
0m
6.1
12.2
40'60' 20' 0' 20' 40' 60'
12.218.3 6.1 0m 6.1 12.2 18.3
80'
24.4 24.4
24.4
0'
40' 12.230.5 30.5
100' 100'
18.360'
Position of vertical planeof maximum candlepower.
CURB LINE
RESTL Test Report #: PL04514-001BXSP-B-**-4ME-A-40K-UL w/XA-SP1BLSInitial Delivered Lumens: 3,973
984
1968
2953
3937150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-4ME-A-40K-UL w/XA-SP1BLSMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 3,983Initial FC at grade
0m6.1 18.312.2
30.5
18.3
18.3
24.4
24.4
0m0'
6.120'
6.120'
60'
80'
100'
12.240'
12.240'
60'
40'
18.3
60' 20'
12.2
40'
6.1
20'0' 60'
24.4
80'
24.4
80'
Position of vertical planeof maximum candlepower.
80'
100'30.5 30.5
30.5
100'100'
.1
.2
45˚
.5
1
CURB LINE
© 2015 Cree, Inc. and/or one of its subsidiaries. All rights reserved. For informational purposes only. Content is subject to change. Patent www.cree.com/patents. Cree®, NanoOptic®, and Colorfast DeltaGuard® are registered trademarks, and the Cree logo, Precision Delivery Grid™ and XSP1™ are trademarks of Cree, Inc. The UL logo is a registered trademark of UL LLC. NEMA® is a registered trademark of the National Electrical Manufacturers Association. The DLC QPL logo is a registered trademark of Northeast Energy Efficiency Partnerships, Inc.
T (800) 236-6800 F (262) 504-5415US: www.cree.com/lighting T (800) 473-1234 F (800) 890-7507Canada: www.cree.com/canada
XSP1™ LED Street/Area Luminaire – Single Module – Version B
PhotometryAll published luminaire photometric testing performed to IESNA LM-79-08 standards by a NVLAP accredited laboratory. To obtain an IES file specific to your project consult: www.cree.com/Lighting/Products/Outdoor/Streetlights/XSP-Series-Streetlight
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
5ME
RESTL Test Report #: PL02880-001BXSP-B-**-5ME-B-40K-ULInitial Delivered Lumens: 8,714
934
1868
2802
3736150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-5ME-A-40K-ULMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 4,049Initial FC at grade
0m6.1 18.312.2
18.3
18.3
0m0'
6.120'
6.120'
60'
24.480'
24.480'
12.240'
12.240'
60'
40'
18.3
60' 20'
12.2
40'
6.1
20'0' 60'
24.4
80'
24.4
80'
.2 .1
Position of vertical planeof maximum candlepower.
0˚
CURB LINE
Type V Medium Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 4,049 B3 U1 G3 4,218 B3 U1 G3
Horizontal Tenon Mount – Weight: 18 lbs. (8kg)
Single 2 @ 90˚ 2 @ 180˚ 3 @ 90˚ 4 @ 90˚
Tenon Configuration If used with Cree tenons, please add tenon EPA with luminaire EPA
PD-1H4; PT-1H PD-2H4(90); PT-2H(90) PD-2H4(180); PT-2H(180) PD-3H4(90); PT-3H(90) PD-4H4(90); PT-4H(90)
0.71 1.02 1.43 1.74 2.04
Tenons and Brackets‡ (must specify color)
Square Internal Mount Horizontal Tenons (Aluminum)- Mounts to 4" (102mm) square aluminum or steel polesPD-1H4 – Single PD-3H4(90) – 90˚ TriplePD-2H4(90) – 90˚ Twin PD-4H4(90) – 90˚ QuadPD-2H4(180) – 180˚ Twin
Wall Mount Brackets- Mounts to wall or roofWM-2L – Extended Horizontal
Round External Mount Horizontal Tenons (Aluminum)- Mounts to 2.375"-3" (60-76mm) O.D. round aluminum or steel poles or tenonsPT-1H – Single PT-3H(90) – 90˚ TriplePT-2H(90) – 90˚ Twin PT-4H(90) – 90˚ QuadPT-2H(180) – 180˚ Twin
Direct Arm Pole Adaptor Bracket - Mounts to 3-6" (76-152mm) round or square aluminum or steel polesXA-TMDA8
Tenon EPA
Part Number EPA
PD Series Tenons 0.09
PT Series Tenons 0.10
WM-2L 0.13
XA-TMDA8 0.19
‡ Refer to the Bracket and Tenons spec sheet for more details
Luminaire EPA
* Initial delivered lumens at 25˚C (77˚F). Actual production yield may vary between -10 and +10% of initial delivered lumens** For more information on the IES BUG (Backlight-Uplight-Glare) Rating visit: www.ies.org/PDF/Erratas/TM-15-11BugRatingsAddendum.pdf. Valid with no tilt
5SH
RESTL Test Report #: PL02880-002BXSP-B-**-5SH-B-40K-ULInitial Delivered Lumens: 9,321
755
1511
2266
3022150°
120° 120°
60°
90° 90°
60°
30°
150°
Candlepower Trace: Vertical plane throughhorizontal angle of maximum candlepower.
BXSP-B-**-5SH-A-40K-ULMounting Height: 25' (7.6m) A.F.G.Initial Delivered Lumens: 4,293Initial FC at grade
0m6.1 18.312.2
18.3
18.3
0m0'
6.120'
6.120'
60'
24.480'
24.480'
12.240'
12.240'
60'
40'
18.3
60' 20'
12.2
40'
6.1
20'0' 60'
24.4
80'
24.4
80'
2 1
Position of vertical planeof maximum candlepower.
45˚
CURB LINE
Type V Short Distribution
Input PowerDesignator
4000K 5700K
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
InitialDeliveredLumens*
BUGRatings** Per TM-15-11
A 4,293 B3 U0 G2 4,472 B3 U0 G2