xtreme performance series cables · high workover costs, corrosive or gas laden conditions, or high...

2
Features and benefits CEB: Barrier cable Provides reliable operations in high H 2 S environments less than 3% and high CO 2 environments less than 10% Lead covering Provides reliable operations in severe levels of H 2 S greater than 3% and severe levels of CO 2 greater than 90% CEL: High temperature cable Offers reliable operations in hot wells Solid copper conductors Prevents gas migration in the cable and increases clearance in the well Armored capillary line cable Allows for pressure measurement, chemical insertion, and diluent insertion Baker Hughes is the only electrical submersible pumping (ESP) system provider that designs and manufactures the complete ESP system, including the power cable. The Xtreme Performance (XP ) series cable is designed to support extended run life for ESP systems in the world’s most hostile oilfield environments. This includes critical wells with high workover costs, corrosive or gas laden conditions, or high temperatures. Our FluoroBarrier CEB (round) cables are rated from -40ºF (-40ºC) to 400ºF (204ºC). FluoroBarrier CEB can operate over a broad temperature range using insulation that is a specially compounded oil resistant EPDM rubber with proven electrical properties. This is covered with an extruded FluoroBarrier layer to provide complete protection from chemicals in well fluids and gases. A patented, high modulus jacket of breathable oil-resistant rubber and galvanized steel armor offer final layers of protection. The Baker Hughes CEL (round or flat) cable is applicable in a wide range of temperatures from -40ºF (-40ºC) to 450ºF (232ºC). CEL cable is the best choice for extreme downhole conditions, featuring a special oil-resistant EPDM rubber insulation for high dielectric strength and excellent decompression resistance. The CPL (flat) cable is rated from -40ºF (-40ºC) to 257ºF (125ºC). CPL cable is best suited for cooler well conditions and Xtreme Performance Series Cables Supports extended run life in harsh environments with rugged construction OVERVIEW | bakerhughes.com

Upload: others

Post on 17-Mar-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Xtreme Performance Series Cables · high workover costs, corrosive or gas laden conditions, or high temperatures. Our FluoroBarrier™ CEB (round) cables are rated from -40ºF (-40ºC)

Features and benefi ts

CEB: Barrier cable

– Provides reliable operations in

high H2S environments less than

3% and high CO2 environments

less than 10%

Lead covering

– Provides reliable operations in

severe levels of H2S greater than

3% and severe levels of CO2

greater than 90%

CEL: High temperature cable

– Offers reliable operations in hot wells

Solid copper conductors

– Prevents gas migration in the

cable and increases clearance in

the well

Armored capillary line cable

– Allows for pressure

measurement, chemical

insertion, and diluent insertion

Baker Hughes is the only electrical

submersible pumping (ESP) system provider

that designs and manufactures the complete

ESP system, including the power cable. The

Xtreme Performance (XP™) series cable is

designed to support extended run life for ESP

systems in the world’s most hostile oilfi eld

environments. This includes critical wells with

high workover costs, corrosive or gas laden

conditions, or high temperatures.

Our FluoroBarrier™ CEB (round) cables are

rated from -40ºF (-40ºC) to 400ºF (204ºC).

FluoroBarrier CEB can operate over a broad

temperature range using insulation that is

a specially compounded oil resistant EPDM

rubber with proven electrical properties. This

is covered with an extruded FluoroBarrier

layer to provide complete protection from

chemicals in well fl uids and gases. A

patented, high modulus jacket of breathable

oil-resistant rubber and galvanized steel

armor offer fi nal layers of protection.

The Baker Hughes CEL (round or fl at) cable

is applicable in a wide range of temperatures

from -40ºF (-40ºC) to 450ºF (232ºC). CEL

cable is the best choice for extreme downhole

conditions, featuring a special oil-resistant

EPDM rubber insulation for high dielectric

strength and excellent decompression

resistance. The CPL (fl at) cable is rated from

-40ºF (-40ºC) to 257ºF (125ºC). CPL cable

is best suited for cooler well conditions and

Xtreme Performance Series CablesSupports extended run life in harsh environments with rugged construction

OVERVIEW| bakerhughes.com

Page 2: Xtreme Performance Series Cables · high workover costs, corrosive or gas laden conditions, or high temperatures. Our FluoroBarrier™ CEB (round) cables are rated from -40ºF (-40ºC)

XP, FluoroBarrier, and AutographPC are trademarks of Baker Hughes Incorporated.

Disclaimer of Liability: This information is provided for general information purposes only and is believed to be accurate as of the date hereof; however, Baker Hughes Incorporated and its affi liates do not make any warranties or representations of any kind regarding

the information and disclaim all express and implied warranties or representations to the fullest extent permissible by law, including those of merchantability, fi tness for a particular purpose or use, title, non-infringement, accuracy, correctness or completeness of the

information provided herein. All information is furnished “as is” and without any license to distribute. The user agrees to assume all liabilities related to the use of or reliance on such information. BAKER HUGHES INCORPORATED AND ITS AFFILIATES SHALL NOT BE

LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL, PUNITIVE, EXEMPLARY OR CONSEQUENTIAL DAMAGES FROM ANY CAUSE WHATSOEVER INCLUDING BUT NOT LIMITED TO ITS NEGLIGENCE.

© 2014 Baker Hughes Incorporated. All rights reserved. 38640 01/2014

features a specially formulated, rugged

polypropylene insulation for damage

resistance and longer run life.

Both CEL and CPL designs employ a fatigue

and corrosion resistant lead sheath over the

insulation for maximum fl exibility and run

life. Lead sheaths are made to Baker Hughes

specifi cations and extruded on state-of-the-

art equipment, using laser diameter controls

for the highest quality and consistency.

These features make CEL and CPL cable ideal

for wells with high gas content or high levels

of CO2 or H

2S.

We employ a proprietary process to

apply the lead sheath directly over the

polypropylene insulation in CPL cables.

For additional protection on CEL cable, a

bedding tape is used to protect the lead

sheath during application of the armor. The

armor on all Baker Hughes cables is edge-

coated on all sides to provide the industry’s

best corrosion protection.

Baker Hughes Capillary (round or fl at) cable

is rated from -30ºF (-34ºC) to 450ºF (232ºC).

Capillary cable uses patented designs and

unique manufacturing methods to incorporate

one or two capillary or bubble tube lines with

the cable. This eliminates the cost of running

separate chemical treatment lines down wells.

The tubes are enclosed in a second armor

layer, which adds more mechanical protection

to the hydraulic tube and ESP power cable.

The additional armor layer allows capillary

tubes to be terminated at any desired location

without disturbing the power cable.

Contact your Baker Hughes representative

today or visit www.bakerhughes.com/esp to

fi nd out how the XP series cable can help

you maximize production in challenging

downhole conditions.

XP Power Cable Characteristics

† Monel® is a registered trademark of the Special Metals Corporation.

*Use AutographPC™ software to determine the operating temperature for cable.

Description Application

Product Conductor Insulation Covering Jacket Confi guration Armor Min Temp* Max Temp* Gas ServicePerformance

Rating

CEBN Copper EPDM Barrier Nitrile RoundGalvanized steel,

stainless steel,

Monel†

-40°F (-40°C) 280°F (138°C)High gas

<3% H2S

Xtreme

Performance

CEBE Copper EPDM Barrier EPDM Round -40°F (-40°C) 300°F (149°C)

CEBE (-HT) Copper EPDM Barrier EPDM Round -60°F (-51°C) 400°F (204°C)

CPL Copper Polypropylene Lead Flat Galvanized steel,

stainless steel,

Monel†

-40°F (-40°C) 257°F (125°C)High CO

2

H2S & CO

2CEL Copper EPDM Lead Round or fl at -40°F (-40°C) 450°F (232°C)

Capillary

cableCopper

Multiple

options;

adaptable to all

cable types

Multiple

options;

adaptable to all

cable types

Round or fl at

Galvanized steel,

stainless steel,

Monel†

-30°F (-34°C) 450°F (232°C)

Baker Hughes cable development and testing center

OVERVIEW