Page 1: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

PD 2/4/2014 | v 1.3Pricing shown is in U.S. DollarsPricing subject to change without notice

YORK HVACPRODUCT GUIDE

Page 2: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

1HVAC Distribution Product Guide

Table of Contents

Mated ERVs ...........................................................................................2OA Hood Economizer Systems ...........................................................3Hood and Duct Part Numbering ..........................................................3Hood and Duct Packages/Options ......................................................4Economizer Systems ........................................................................5-6Sensors .................................................................................................7Accessories .......................................................................................8-9Notes....................................................................................................10RTU Reference Guide.........................................................................11

iAIRE, LLC6805 Hillsdale Court

Indianapolis, IN 46250

www.myiaire.com | 800-886-2281

Page 3: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

2HVAC Distribution Product Guide

MATED ERVs

MATED ERV PART NUMBERING SCHEME

PLEASE NOTE: It is assumed that the RTU fan is running at 400 CFM/Ton (i.e. If the RTU is a 6 ton unit, the RTU fan is running at 2,400 CFM).

Min OA ERV is sized for 33% of the total fan capacity of the RTU (i.e. If the ERV is mated to a 6 ton unit, the ERV would be sized for 800 CFM).

The IAQ ERV is sized to handle the same amount of outside air as the Min OA ERV, but uses the iAIRE patent pending technol-ogy to reduce the size of the ERV wheel.

Both the Min OA ERV and the IAQ ERV come standard with the following accessories: Built in economizer damper, Controller that controls both the ERV and economizer, VOC sensor, CO2 sensor, two (2) temperature probes (outside air and supply air), variable quantity of ionization devices sized to handle the airflow of the RTU.

EMsize

A - IAQ LOWB - IAQ STDC - IAQ HIGHD - MIN OA LOWE - MIN OA STDF - MIN OA HIGH

unit/tonSUN36PRED 36PRED 712SUN15SUN1725

voltage control0 - ELECTRO MECHA - IAQ

options0 - NO OPTIONSC - BUILDING PRESSD - FROST PROTECTE - HUMIDITY SENSF - BACNETK - HORIZ RA RTU

maintenanceindicator

0 - NO INDICATORSA - DIRT FILT INDIC

disconnect0 - NO DISCONNECTA - 240 V NON FUSEDB - 240 V FUSEDC - 600 V NON FUSEDD - 600 V FUSED

wheelA - TOTL ENTHLPYB - SENSIBLE ONLYC - PURGE

Page 4: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

3HVAC Distribution Product Guide

HD * * - * - * *options

0 - NO OPTIONSA - HUM / ENTHB - BACNETC - AIRFLOW MON.D - LL DAMPER

package0 - NO PACKAGEA - IAQB - DCVC - ECOND - CO2 DIRECT CNTRL

unit/ton

PRED36PRED712SUN36SUN15SUN17251010 - 10x10 DUCT2020 - 20x20 DUCT

sizeA - RTU OA HDB - RTU ECON HDC - DUCTD - ERV IAQ OA HDE - ERV IAQ EX HDF - ERV MINOA OA HDG - ERV MINOA EX HD

accessory0 - NONEC - MODULAT DMPER

OA HOOD ECONOMIZER SYSTEMS

OA HOOD WITH ECONOMIZER PACKAGE PART NUMBER

OUTSIDE AIR HOOD ECONOMIZER PACKAGEFor units that have a modulating damper, the unit is equipped with a damper and modulating actuator on it. You need to have a modulating damper to pick any of the package options in digit 4.

*Contact factory for additional duct sizes

21 3 4 5

AIRFLOW HOODS AND DUCTS All flow hood and duct units have airflow sensing technology built into the package so units read accurately once installed.

All units also have the ability to change standard economizer controllers to CFM based control systems and can bring CFM points out to BACnet.

All units eligible for LEED credit with CFM output and a low CFM alarm point.

ERV HOODS All ERV hoods must be ordered when ordering the ERV. Hoods for the ERV can only add the airflow option as the ERV will include package and accessory components based on ERV ordered.

Page 5: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

4HVAC Distribution Product Guide

HOOD AND DUCT PACKAGES/OPTIONSThe base airflow monitoring hood or duct (selected in the 4th and 8th digit of the part number) has airflow sensing technology built into the package so units read accurately once installed. They have the ability to change standard economizer controllers to CFM based control systems and can bring CFM points out to BACnet.

When you add a modulating damper (selected in the 4th digit of the part number), a modulating damper will be added to the hood. A controls package should be selected (8th digit of the part number) to control the damper. The packages are as follows:

IAQ (A) - Supplied with controller, VOC sensor, CO2 sensor, temperature probes (2) and ionization devices. This will allow you to monitor CFM through the hood and will reduce our OA with the iAIRE patent pending process. DCV (B) - Supplied with controller, CO2 sensor and temperature probes (2). This will allow you to monitor CFM through the hood while controlling the damper based on CFM.

ECON (C) - Supplied with controller and temperature probes (2). This will allow you to monitor CFM through the hood while controlling the damper to a set CFM position.

CO2 DIRECT CONTROL (D) - Supplied with CO2 sensor. This will allow for output from the CO2 sensor directly to the modulating damper to control the damper.

Options that come with the airflow hoods and ducts are as follows:

HUM / ENTH (A) - For use when converting any of the packages from dry bulb to wet bulb or enthalpy control of the damper.

BACNET (B) - For use when translating values from the system and sending them out to BACnet.

Page 6: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

5HVAC Distribution Product Guide

ECONOMIZER SYSTEMSIAQ CONTROLS PACKAGEThe iAIRE IAQ controls packages come with the items and quantity outlined below. These packages will allow you to reduce the amount of outside air needed by up to 2/3 and will improve your indoor air quality. This system is set up to go directly on an existing economizer or OA hood that has a modulating damper. The packages are a lower cost alternative to buying each part individually.

Ionizationair cleaner

mod. # ION-0A*00

Page 7: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

6HVAC Distribution Product Guide

ECONOMIZER SYSTEMSCONTROLLERThe iAIRE economizer controller is used to control the economizer actuator and all sensors to achieve outdoor air savings and clean air unlike any other system before.

PART NUMBERSIAIRE-1000

BACnet TRANSLATORThe iAIRE BACNet translator provides reliable protocol translation for your system.

PART NUMBERSTRANS-AE-001 (Econ & ERV board)TRANS-AH-001 (Hood)

Page 8: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

7HVAC Distribution Product Guide

SENSORS

TEMPERATURE PROBEiAIRE’s 10K, type 2, NTC temperature transmitters are a cost effective solution for all of your temperature measurement needs. The transmitters are accurate, durable, and reliable.

PART NUMBERSTP-B-0-J-02-72-A

HUMIDITY SENSORiAIRE’s humidity sensors are great for high end HVAC, clean rooms, green houses and other locations needing to measure temperature and humidity. It also offers the ability to determine enthalpy in HVAC systems. 0-10V or 4-20mA output.

PART NUMBERSSEN-HUM-A-02-02-0

VOC SENSORThe iAIRE VOC sensor is a versatile product and can be mounted to any standard wall. It is designed for VOC detection and should not be used as a safety detector (for example, a gas alert detector). 0-10V or 4-20mA output.

PART NUMBERSSEN-VOC-A-01-01-0

CO2 SENSORThe iAIRE CO2 detector provides real-time CO2 levels and is designed for basic application in HVAC and ventilation systems applications. 0-10V or 4-20mA output.

PART NUMBERSSEN-CO2-B-01-01-0

BUILDING PRESSURE SENSORThe iAIRE building pressure sensor offers low-pressure measurement for building energy management and comfort control. 0 - 0.25” w.c.

PART NUMBERSSEN-DP-C-01-03-0

Page 9: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

8HVAC Distribution Product Guide

ACCESSORIES20 IN-LB ACTUATORiAIRE’s low torque actuator works on small dampers, economizer units, residential zoning equipment as well as terminal units.

PART NUMBERSMTR-0002

62 IN-LB ACTUATORiAIRE’s medium torque actuator works on outside air dampers, mixing boxes, small rooftop units, return air dampers, zone isolation dampers and economizer units.

PART NUMBERSMTR-0003

160 IN-LB ACTUATORiAIRE’s high torque actuator works on outside air dampers, mixing boxes, rooftop units, return air dampers, zone isolation dampers and vortex dampers.

PART NUMBERSMTR-0004

ACTUATOR FLOOR MOUNTMounting kit allows for foot mounting of the actuator. Mounting should be used for in-the-air stream applications or other acceptable location for foot mounting.

PART NUMBERSMTR-0006

ACTUATOR FRAME MOUNTMounting kit allows for direct mounting of actuator to the damper frame. Should be used with louvers and vents as well as when floor mounting is not permitted.

PART NUMBERSMTR-0007

Page 10: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

9HVAC Distribution Product Guide

ACCESSORIESACTUATOR WALL MOUNTMounting kit allows for economical mounting of the actuator to a variety of surfaces. Mount should be used where the actuator can be rigidly mounted and a linear stroke output is required.

PART NUMBERSMTR-0008

MOUNTING PLATEThe iAIRE mounting plate offers easy mounting when you have multiple ion air cleaners for your system. It is located near the inlet to the HVAC supply blower so ion air cleaners can mount easily and provide optimized ion coverage.

PART NUMBERSUNV0016

24V TRANSFORMERThe iAIRE transformer is to be used when additional power is needed on your rooftop unit to support the ionization air cleaner system. 75KV with built in circuit breaker.

PART NUMBERSTRN-0002

Page 11: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

10HVAC Distribution Product Guide

NOTES

Page 12: YORK HVAC PRODUCT GUIDE - iAIRE HVAC and air … Boo… ·  · 2018-02-12YORK HVAC PRODUCT GUIDE. HVAC Distribution Product Guide 1 Table of Contents Mated ERVs ... MATED ERV PART

11York Branded Units

YORK JOHNSON CONTROLS COLEMAN LUXAIRE

CHASSISCLASSIFICATION

UNIT PART NUMBER

UNIT PART NUMBER UNIT PART NUMBER UNIT PART

NUMBER

PREDATOR 36

ZR/ZH 037,049,061,078,090;ZJ 037,049,061;XP/ZF 078,090;DM/DF 090,102;DH 078,090,102

JA3-JA5 ZH/ZJ;J06-J07 ZH/ZF/ZR/XP

ZU/ZK A3-07; ZS 06-07;ZW/ZV A3-A5; DS/DL 07-08;DU 06-08; XA/BA 07

ZU/ZK A3-07; ZS 06-07; ZW/ZV A3-A5;DS/DL 07-08; DU 06-08; XA/BA 07

PREDATOR 712

ZF/XP/ZH/ZR 102,120,150;ZJ 078,090,102,120,150;DF 078,120; DM/DH 120,150;DJ 150; DR 090,120,150

J06-J12 ZJ;J08-J12 ZH/ZF/ZR/XP;

ZU/ZK/ZS 08-12; ZW 06-12;DW 12; DK 07-10; DS 06,10;DU 10-12; DL 06,10,12;XA/BA 06,08-12

ZU/ZK/ZS 08-12;ZW 06-12; DW 12;DK 07-10; DS 06,10;DU 10-12; DL 06,10,12; XA/BA 06,08-12

SUN 36

ZR/XP/DJ/ZJ 036,048,060;ZF/DR/DM/DF/DH/DCG/DCE 036,048,060,072

J03-J06 ZF;J03-J05 ZR/XP/ZJ/ZH

XA/DW/DG 03-05;ZS/ZK/DK/BA 03-A6

XA/DW/DG 03-05;ZS/ZK/DK/BA 03-A6

SUN 15

ZF/DM 180 J15 ZF ZS/DU/DL/BA 15 ZS/DU/DL/BA 15

SUN 1725

ZF/DH 210-300;DJ/ZJ/ZR/DR 180-300;XP 180-240; DM 240-300

J28,J20,J25 ZF;J15,J18,J20,J25 ZR/ZJ

ZW/ZK/DW/WW/WK/DK 15-25;ZS/DU 18-25; DL 20-25;XA 15-20; BA/BB 20

ZW/ZK/DW/WW/WK/DK 15-25;ZS/DU 18-25; DL 20-25; XA 15-20; BA/BB 20

YORK CHASSIS REFERENCE GUIDE