z:aa n45 jobs 414-027 expansion ecole elementaire publique ... · 6/2/2015 · january 2015 rm gm...
TRANSCRIPT
1 2 3 5 7 9 11 12
A
B
C
D
A
3 4 6 8 10 12
2
AB
3283 8624 7520 7520 7520 148613005
12477
12477
7520 7520 7520 7520 2590
3405
9855
610
2795
5725
4130
9855
6209
190
1.9
12815
102
ART ROOM
104
CLASSROOM
106
CLASSROOM
100
CORRIDOR
107
CLASSROOM
105
CLASSROOM
103
CLASSROOM
101
CLASSROOM
118
STORAGE
117
JANITOR
113
BOYS
W/C
114
GIRLS
W/C
115
COPY RM
103.1
101.1
107.1
105.1
106.1
104.1
102.1
ST1
STAIR 1
ST
1.2
115.1
116.1
116
STAFF
W/C
117.1
118.1
XA301
XA301
XA301
XA301
XA301
XA301
XA301
XA301
W1
W1
W1
P1
P1
P2
P2
P2
P2P2P2
P4P4
P2P2P2
P2P2P2
P2
W1 W1W1
W1
W1
W1W1W1W1
P1
ST
1.1
ST2
STAIR 2
ST
2.2
ST2.1
108
SUMP ROOM
P2
109
ELEVATOR
MACH. RM
108.1
108.2
109.1
LEVEL 1 FLOOR PLAN LAYOUT
AS NOTED ML
JANUARY 2014 GM
SCALE 1:100
LEVEL 1 FLOOR PLANA101
1
seal
DO NOT SCALE DRAWINGS.
DISCREPANCIES BEFORE WORK COMMENCES.
AND NOTIFY THE ARCHITECT OF ANY
CONTRACTOR TO VERIFY ALL DIMENSIONS
project
drawing title
scale
date
numberproject
revision
drawing number
checked by
drawn by
14-027
north
1385 HALTON TERRACE
KANATA, ONTARIO
EXPANSION ÉCOLEÉLÉMENTAIREPUBLIQUE DE KANATA
no. revision date
1 ISSUED FOR SITE PLAN CONTROL 19 MAY 2015
133
CLASSE
136
ENTREPOT
134
BUREAU
137VESTIBULE
138
CLASSE
139
CLASSE
170
TOILETTES
GAR
CONS
169CONC.
169
168
170
139
138
136
134
133
137.1
1
2
3
4
5
A
B
9B
8B
7B
6B
1 2 3 5 7 9 11 12
A
B
C
D
A
3 4 6 8 10 12
2
AB
3283 8624 7520 7520 7520 148613005
12477
12477
7520 7520 7520 7520 2590
3405
9855
610
2795
5725
4130
9855
6209
190
1.9
12815
MW
DW
RE
F.
RE
F.
CO
MP
UT
ER
DW
REF.
REF.
MW
MW
MW
MW
202
CLASSROOM
204
CLASSROOM
206
CLASSROOM
200
CORRIDOR
207
CLASSROOM
205
CLASSROOM
203
CLASSROOM
201
CLASSROOM
210
CORRIDOR
212
TEACHERS
PREP.
211
MULTIPURPOSE
218
IT
217
JANITOR
213
BOYS
W/C
214
GIRLS
W/C
215
COPY RM
XA301
XA301
XA301
203.1
201.1
207.1
205.1
206.1
204.1
202.1
212.1
210.1
211.1
211.2
ST1
STAIR 1
ST
1.3
215.1
216.1
216
STAFF
W/C
217.1
218.1
W1
W2
W1
W1
XA301
XA301
XA301
XA301
W2
W2
5433
DNUP
DN
XA301
UP
DNUP
S1
P1
P1
P2
P2
P2
P2P2P2
P4P4
P5
P2P2P2
P2P2P2
S1
S1
P3
P3
P4
S1
P2
211A
STORAGE
211.2
211.3
P5
P2
P1
ST2
STAIR 2
W1 W1W1
W1
W1
W1W1W1W1
W2
P1
P5
W2
P4
ST
1.1
P2
P5
W2W2
ST
2.3
P4
LEVEL 2 FLOOR PLAN LAYOUT
AS NOTED ML
JANUARY 2014 GM
SCALE 1:100
LEVEL 2 FLOOR PLANA102
1
seal
DO NOT SCALE DRAWINGS.
DISCREPANCIES BEFORE WORK COMMENCES.
AND NOTIFY THE ARCHITECT OF ANY
CONTRACTOR TO VERIFY ALL DIMENSIONS
project
drawing title
scale
date
numberproject
revision
drawing number
checked by
drawn by
14-027
north
1385 HALTON TERRACE
KANATA, ONTARIO
EXPANSION ÉCOLEÉLÉMENTAIREPUBLIQUE DE KANATA
no. revision date
1 ISSUED FOR SITE PLAN CONTROL 19 MAY 2015
1 2 3 5 7 9 11 12
A
B
C
D
A
3 4 6 8 10 12
2
AB
3283 8624 7520 7520 7520 148613005
12477
12477
7520 7520 7520 7520 2590
3405
9855
610
2795
5725
4130
9855
6209
190
1.9
12815
302
MUSIC ROOM
304
CLASSROOM
306
CLASSROOM
300
CORRIDOR
307
CLASSROOM
305
CLASSROOM
303
CLASSROOM
301
CLASSROOM
318
STORAGE
317
JANITOR
313
BOYS
W/C
314
GIRLS
W/C
315
COPY RM
303.1
301.1
307.1
305.1
306.1
304.1
302.1
ST1
STAIR 1
ST
1.4
315.1
316.1
316
STAFF
W/C
317.1
318.1
XA301
XA301
XA301
XA301
XA301
XA301
XA301
XA301
W1
W1
W1
W2
P1
P1
P2
P2
P2
P2P2P2
P4P4
P5
P2P2P2
P2P2P2
P5
P2
W1 W1W1
W1
W1
W1W1W1W1
W2
P1
W2
W2W2
W1
W1
W1
ST
2.4
P5
P2
W2W2
LEVEL 3 FLOOR PLAN LAYOUT
AS NOTED ML
JANUARY 2014 GM
SCALE 1:100
LEVEL 3 FLOOR PLANA103
1
seal
DO NOT SCALE DRAWINGS.
DISCREPANCIES BEFORE WORK COMMENCES.
AND NOTIFY THE ARCHITECT OF ANY
CONTRACTOR TO VERIFY ALL DIMENSIONS
project
drawing title
scale
date
numberproject
revision
drawing number
checked by
drawn by
14-027
north
1385 HALTON TERRACE
KANATA, ONTARIO
EXPANSION ÉCOLEÉLÉMENTAIREPUBLIQUE DE KANATA
no. revision date
1 ISSUED FOR SITE PLAN CONTROL 19 MAY 2015
1 2 3 5 7 9 11 12
A
B
C
D
A
3 4 6 8 10 12
2
AB
3283 8624 7520 7520 7520 148613005
12477
12477
7520 7520 7520 7520 2590
3405
9855
610
2795
5725
4130
9855
6209
190
1.9
12815
XA301
XA301
XA301
XA301
XA301
XA301
XA301
XA301
RD
RD
RD
RD
RD
RD
SCU
PPER
SCU
PPER
SCUPPER
SCU
PPER
SLOPED STRUCTURE
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
TI
HIGH POINT
SLOPED STRUCTURE
SLOPED STRUCTURE
TI
TI
TI
TI
TI
TI
TI
TI
SLO
PE
D S
TR
UC
TU
RE
SLO
PE
D S
TR
UC
TU
RE
TI
TI
TI
RTU
RTU RTU
RTU
RTURTU
1,070mm HIGH GUARDRAIL
9576
ROOF PLAN
AS NOTED ML
JANUARY 2014 GM
SCALE 1:100
ROOF PLANA104
1
seal
DO NOT SCALE DRAWINGS.
DISCREPANCIES BEFORE WORK COMMENCES.
AND NOTIFY THE ARCHITECT OF ANY
CONTRACTOR TO VERIFY ALL DIMENSIONS
project
drawing title
scale
date
numberproject
revision
drawing number
checked by
drawn by
14-027
north
1385 HALTON TERRACE
KANATA, ONTARIO
EXPANSION ÉCOLEÉLÉMENTAIREPUBLIQUE DE KANATA
no. revision date
1 ISSUED FOR SITE PLAN CONTROL 19 MAY 2015
3 4 6 8 10 12
LEVEL 192.390
LEVEL 2
EXISTING BLDG FLOOR
94.550
LEVEL 3
96.170
99.950
T/O DECK103.870
MULTI-PURPOSE94.550
T/O EXIST. SCHOOL94.550
T/O MULTI-PURPOSE ROOFT/O GYMNASIUM ROOF102.080 102.080
T/O SCHOOL ROOF99.280
T/O NEW SCHOOL ROOF104.160
2590
32670
7520752075207520
3920
3780
1610
2170 3780
11480
2082
7530
4400
7530
P1P1
P1P1
P1
S1
S1
S1
1235791112
LEVEL 192.390
LEVEL 296.170
LEVEL 399.950
T/O LANDING93.650
T/O LANDING97.970
T/O DECK103.800
T/O GYMNASIUM ROOF102.080
T/O MULTI-PURPOSE ROOF102.080
T/O NEW SCHOOL ROOF104.160
7530
1486 7520 7520 7520 8624 3100
35770 13200
P1P1 P1 P1 P1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1
S1 S1 S1
S1 S1 S1 S1 S1 S1 S1
ABCD
LEVEL 296.170
LEVEL 399.950
T/O DECK103.800
T/O DECK103.870
LEVEL 192.390
LEVEL 296.170
LEVEL 399.950
LEVEL 192.390
3780
3780
3920
9855 3405 9855
23115
11480
S1
S1
S1
S1
S1
P1P1 P1 P1
T/O MULTI PURPOSE RM94.550
A
T/O MULTI-PURPOSE ROOF102.080
12369
7530
P1
P1
P1
PROPOSED SCHOOL ELEVATIONSAND EXISTING SCHOOL ELEVATIONS
AS NOTED ML
JANUARY 2015 RM GM
seal
DO NOT SCALE DRAWINGS.
DISCREPANCIES BEFORE WORK COMMENCES.
AND NOTIFY THE ARCHITECT OF ANY
CONTRACTOR TO VERIFY ALL DIMENSIONS
project
drawing title
scale
date
numberproject
revision
drawing number
checked by
drawn by
14-027
north
1385 HALTON TERRACE
KANATA, ONTARIO
EXPANSION ÉCOLEÉLÉMENTAIREPUBLIQUE DE KANATA
no. revision date
P1CAST-IN-PLACE CONCRETE TILT-UP PANEL- FINISH
4-TEXTURED SURFACE.
S1ALUMINUM SPANDREL PANEL
1 ISSUED FOR SITE PLAN CONTROL 19 MAY 2015