z/OS Basic Skills Information Center
z/OS system installation and management
���
z/OS Basic Skills Information Center
z/OS system installation and management
���
Note
Before using this information and the product it supports, read the information in “Notices” on page 67.
This edition applies to z/OS (product number 5694-A01).
We appreciate your comments about this publication. Comment on specific errors or omissions, accuracy,
organization, subject matter, or completeness of this book. The comments you send should pertain to only the
information in this manual or product and the way in which the information is presented.
For technical questions and information about products and prices, please contact your IBM branch office, your IBM
business partner, or your authorized remarketer.
When you send comments to IBM, you grant IBM a nonexclusive right to use or distribute your comments in any
way it believes appropriate without incurring any obligation to you. IBM or any other organizations will only use
the personal information that you supply to contact you about the issues that you state on this form.
Send your comments through this Web site: http://publib.boulder.ibm.com/infocenter/zoslnctr/v1r7/index.jsp?topic=/com.ibm.zcontact.doc/webqs.html
© Copyright International Business Machines Corporation 2005, 2008.
US Government Users Restricted Rights – Use, duplication or disclosure restricted by GSA ADP Schedule Contract
with IBM Corp.
Contents
z/OS system management roles and
tasks . . . . . . . . . . . . . . . . v
Part 1. Installation of z/OS and other
software products . . . . . . . . . 1
Chapter 1. z/OS base elements and
optional features . . . . . . . . . . . 3
Chapter 2. Methods of installing z/OS . . 7
Chapter 3. Typical organization of IBM
and other software in storage . . . . . 9
Part 2. z/OS system customization 11
Chapter 4. z/OS system libraries . . . . 13
Chapter 5. System symbols in
PARMLIB . . . . . . . . . . . . . . 15
Chapter 6. Search order for programs 17
Chapter 7. Input/output (I/O) device
configuration . . . . . . . . . . . . 19
Chapter 8. Console configuration . . . 21
Part 3. Starting z/OS: The
initialization (IPL) process . . . . . 25
Chapter 9. System IPL: Sequence and
key controls . . . . . . . . . . . . 27
Chapter 10. System IPL: Address space
creation and subsystem initialization . . 31
The master scheduler subsystem . . . . . . . 31
The job entry subsystem (JES) . . . . . . . . 32
Initialization of additional subsystems . . . . . 33
Chapter 11. System IPL: Description of
IPL types . . . . . . . . . . . . . . 35
Part 4. z/OS system tuning . . . . . 37
Part 5. z/OS software maintenance 39
Chapter 12. z/OS conventions:
Following a process of change control . 41
Chapter 13. System installation and
maintenance using SMP/E . . . . . . 45
The SMP/E view of the system . . . . . . . . 45
How the SMP/E environment is similar to a public
library . . . . . . . . . . . . . . . . 47
SMP/E data sets for inventory, zones, and libraries 48
What is a SYSMOD? . . . . . . . . . . . 50
Function SYSMOD: Introducing an element in
the system . . . . . . . . . . . . . . 51
PTF SYSMOD: Preventing or fixing problems
with an element . . . . . . . . . . . . 52
APAR SYSMOD: Fixing problems with an
element . . . . . . . . . . . . . . . 54
USERMOD SYSMOD: Customizing an element 55
Best practice: Keep track of system elements and
modifications . . . . . . . . . . . . . 56
The SMP/E process for installing z/OS elements or
service . . . . . . . . . . . . . . . . 57
SMP/E commands . . . . . . . . . . . . 58
The SMP/E RECEIVE command . . . . . . 59
The SMP/E APPLY command . . . . . . . 60
The SMP/E ACCEPT command . . . . . . 62
Part 6. Appendixes . . . . . . . . . 65
Notices . . . . . . . . . . . . . . 67
Programming interface information . . . . . . 68
Trademarks . . . . . . . . . . . . . . 69
© Copyright IBM Corp. 2005, 2008 iii
iv z/OS Basic Skills Information Center: z/OS system installation and management
z/OS system management roles and tasks
The job of the z/OS® system programmer is very complex and requires skills in
many aspects of the system. The role of the z/OS system programmer can vary
from one installation to another, but usually includes installing, customizing, and
maintaining the operating system. In most large z/OS installations, system
programmers become specialists for only specific tasks.
Generally speaking, the system programmer is responsible for managing the
mainframe hardware configuration, and installing, customizing, and maintaining
the mainframe operating system. System programmers ensure that their
installation’s system and its services are available and operating to meet service
level agreements. Installations with 24-hour, 7-day operations need to plan for
minimal disruption of their operation activities.
The role of system programmer usually includes some degree of involvement in all
of the following aspects of system operation shown in Figure 1.
“Separation of duties” enables specialization
In a large z/OS installation, there is usually a separation of duties both among
members of the system programming staff, and between the system programming
department and other departments in the IT organization. A typical z/OS
installation includes the following roles and more:
v z/OS system programmer
v CICS® system programmer
v Database system programmer
v Database administrator
v Network system programmer
Figure 1. Some areas in which the system programmer is involved
© Copyright IBM Corp. 2005, 2008 v
v Automation specialist
v Security manager
v Hardware management
v Production control analyst
v System operator
v Network operator
v Security administrator
v Service manager
In part, the separation is an audit requirement– ensuring that one person does not
have too much power on a system.
When a new application is to be added to a system, for example, a number of
tasks need to be performed before the application can be used by end users. A
production control analyst is needed to add batch applications into the batch
scheduling package, add the new procedures to a procedure library, and set up the
operational procedures. The system programmer is needed to perform tasks
concerned with the system itself, such as setting up security privileges and adding
programs to system libraries. The programmer is also involved with setting up any
automation for the new application.
On a test system, however, a single person might have to perform all the roles,
including being the operator, and this is often the best way to learn how
everything works.
vi z/OS Basic Skills Information Center: z/OS system installation and management
Part 1. Installation of z/OS and other software products
To install means to perform the tasks necessary to make the system operational,
starting with a decision to either install for the first time or upgrade, and ending
when the system is ready for production.
An installation plan is a record of the actions you need to take to install z/OS.
© Copyright IBM Corp. 2005, 2008 1
2 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 1. z/OS base elements and optional features
The z/OS operating system consists of base elements and optional features.
v The base elements (or simply elements) deliver essential operating system
functions. Base elements include:
The Base Control Program (BCP)
The BCP provides essential operating system services. The BCP includes
the I/O configuration program (IOCP), the workload manager (WLM),
system management facilities (SMF), the z/OS UNIX® System Services
(z/OS UNIX) kernel, the program management binder, and other
components.
Common Information Model (CIM)
CIM is a standard data model for describing and accessing systems
management data in heterogeneous environments. It allows system
administrators to write applications that measure system resources in a
network with different operating systems and hardware.
Communications Server
Communications Server (also known as CS z/OS) supports secure
TCP/IP, SNA, and UNIX networking throughout an enterprise. It gives
you the ability to connect subsystems and applications to each other, and
to connect network devices (such as terminals and printers) to the
system.
Cryptographic Services
Cryptographic Services provides the following base cryptographic
functions: data secrecy, data integrity, personal identification, digital
signatures, and the management of cryptographic keys. Keys as long as
56 bits are supported by this base element.
DFSMSdfp™
DFSMSdfp provides storage, data, program, and device management
functions.
Distributed File Service
Distributed File Service provides:
– The DCE file serving (DFS(TM)) component of the Open Group Open
Software Foundation (OSF) DCE. The file serving support (the DFS™
client and server) is at the OSF 1.2.2 level.
– The zSeries® File System (zFS). The zFS is a UNIX file system that can
be used in addition to the hierarchical file system (HFS). zFS file
systems contain files and directories that can be accessed with the
z/OS hierarchical file system file APIs. zFS file systems can be
mounted into the z/OS UNIX hierarchy along with other local (or
remote) file system types (such as HFS, TFS, AUTOMNT, and NFS).
The zFS does not replace the HFS; it is complementary to the HFS.
Hardware Configuration Definition (HCD)
HCD defines both the operating system configuration and the processor
hardware configuration for a system.
IBM® HTTP Server
IBM HTTP Server is the Web server for z/OS. It provides scalable, high
performance Web serving for critical e-business applications. It supports
© Copyright IBM Corp. 2005, 2008 3
Secure Sockets Layer (SSL) secure connections, dynamic caching using
the Fast Response Cache Accelerator, multiple IP addresses, proxy
authentication, and double-byte character set characters.
Integrated Security Services
Integrated Security Services provides base security functions for z/OS.
Its components include:
– DCE Security Server, which uses the limited DES algorithm for
encryption.
– Enterprise Identity Mapping (EIM), which allows you to map a user’s
identity on one system to the user’s identity on another system.
– Network Authentication Service, which uses the DES algorithm for
encryption.
Interactive System Productivity Facility (ISPF)
ISPF provides facilities for all aspects of host-based software
development. ISPF has four major components: Dialog Manager,
Program Development Facility, Software Configuration and Library
Manager, and the Client/Server component.
Job entry subsystem (JES)
z/OS installations may use one of two job entry subsystems; a job entry
subsystem accepts the submission of work for the BCP.
– JES2 exercises independent control over its job processing functions.
– JES3 exercises centralized control.
JES2 is a base element of z/OS; JES3 is an optional feature.
Language Environment®
Language Environment provides the run-time environment for programs
generated with C, C++, COBOL, Fortran, and PL/I.
Network File System (NFS)
NFS acts as a file server to workstations, personal computers, or other
authorized systems in a TCP/IP network.
System Modification Program Extended (SMP/E)
SMP/E is a tool for installing and maintaining software, and for
managing the inventory of software that has been installed.
Time Sharing Option/Extensions (TSO/E)
TSO/E allows users to create an interactive session with the z/OS
system. TSO provides a single-user logon capability and a basic
command prompt interface to z/OS.
z/OS UNIX System Services (z/OS UNIX)
z/OS UNIX provides the standard command interface familiar to
interactive UNIX users.v The optional features (or simply features) are orderable with z/OS and provide
additional operating system functions. Optional features include:
DFSMSdss™
DFSMSdss copies and moves data for backup and recovery, and to
reduce free-space fragmentation.
DFSMShsm™
DFSMShsm provides automated DASD storage management, including
space management for low and inactive data, and availability
management for accidental data loss caused by local and site disasters.
DFSMShsm also lets you make effective use of tape media.
4 z/OS Basic Skills Information Center: z/OS system installation and management
DFSMS™ Transactional VSAM Services (DFSMStvs)
DFSMStvs enables batch jobs and CICS online transactions to update
shared VSAM data sets concurrently.
DFSORT™
DFSORT provides fast and easy sorting, merging, copying, reporting,
and analysis of your business information, as well as versatile data
handling at the record, field, and bit level.
Infoprint Server
Infoprint Server allows you to print files on z/OS printers from any
workstation that has TCP/IP access.
Resource Measurement Facility (RMF™)
RMF gathers data about z/OS resource usage and provides reports at
any system in a sysplex.
System Display and Search Facility (SDSF)
SDSF provides you with information to monitor, manage, and control
your z/OS system.
Chapter 1. z/OS base elements and optional features 5
6 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 2. Methods of installing z/OS
Several IBM packages are available for installing z/OS. Some are entitled with the
product (as part of your z/OS license, at no additional charge), while others are
available for an additional fee.
The most commonly used methods of installation include:
ServerPac
ServerPac is an entitled software delivery package consisting of products
and service for which IBM has performed the SMP/E installation steps and
some of the post-SMP/E installation steps. To install the package on your
system and complete the installation of the software it includes, you use
the CustomPac Installation Dialog.
Custom-Built Product Delivery Option (CBPDO)
CBPDO is an entitled software delivery package consisting of uninstalled
products and unintegrated service. There is no dialog program to help you
install, as there is with ServerPac. You must use SMP/E to install the
individual z/OS elements and features, and their service, before you can
IPL.
SystemPac®
SystemPac is a software package, available for an additional fee and
offered worldwide, that helps you install z/OS, subsystems (DB2®, IMS™,
CICS, NCP, and WebSphere® Application Server), and selected vendor
products. SystemPac is tailored to your specifications; it is manufactured
according to parameters and input/output definition file (IODF) definitions
that you supply during order entry.
© Copyright IBM Corp. 2005, 2008 7
8 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 3. Typical organization of IBM and other software in
storage
Your installation’s operating system environment consists of several different types
of code and data– some supplied by IBM, some by other vendors, or some by your
company’s programmers– all of which combine to make your z/OS system unique.
Once these software products and applications have been organized and stored,
system programmers spend much of their time planning when to install updates or
new software products, how to test them, and when to move them into production
systems without adversely affecting workloads.
Figure 2 illustrates the different types of software code and data that exist in a
system, and how they are usually organized in system storage.
The z/OS software– as supplied by IBM– is usually installed on a series of disk
volumes known as the system residence volumes (SYSRES). Much of the flexibility
of z/OS is built on these SYSRES sets. They make it possible to apply maintenance
to a new set that is cloned from the production set while the current set is running
production work. A short outage can then be taken to IPL from the new set--and
the maintenance has been implemented! Also, the change can be backed out by
IPLing from the old set.
Fixes to z/OS are managed with a product called System Modification
Program/Extended (SMP/E). Indirect cataloging using system symbols is used so
that a particular library is cataloged as being on, for example, SYSRES volume 2,
and the name of that volume is resolved by the system at IPL time from the
system symbols.
Figure 2. Typical organization of software
© Copyright IBM Corp. 2005, 2008 9
Other IBM software (such as CICS and DB2), and non-IBM or third-party vendor
software products are usually installed on another group of volumes, rather than
on the SYSRES volumes. The SYSRES sets are usually managed as one entity by
SMP/E, so their content is usually limited to z/OS software. The non-z/OS
software is installed on as many volumes as are required, and thus can be
managed separately.
Another group of volumes is reserved for customization data, which refers to data
such as the z/OS system libraries (SYS1.PARMLIB and SYS1.PROCLIB, for
example); the master catalog; the I/O definition file (IODF); page data sets; job
entry subsystem (JES) spools; the /etc directory; and other items that are essential
to the running of the z/OS system. It is also where SMP/E data is stored to
manage the software.
These data sets are not always located on separate DASD volumes from
IBM-supplied z/OS software; some installations place the PARMLIB and PROCLIB
on the first SYSRES pack, others place them on the master catalog pack or
elsewhere. This is a matter of choice and is dependent on how the SYSRES
volumes are managed. Each installation will have a preferred method.
On many systems, some of the IBM-supplied defaults are not appropriate, so they
need to be modified. User exits and user modifications (usermods) are made to
IBM code so that it will behave as the installation requires. The modifications are
usually managed using SMP/E.
Finally, another set of volumes contains production, test, and user data; this set is
usually the largest pool of disk volumes. This set of volumes is not part of the
system libraries, but is presented here for completeness. It is often split into pools
and managed by System Managed Storage (SMS), which can target data to
appropriately managed volumes. For example, production data can be placed on
volumes that are backed up daily, whereas user data may only be captured weekly
and may be migrated to tape after a short period of inactivity to free up the disk
volumes for further data.
10 z/OS Basic Skills Information Center: z/OS system installation and management
Part 2. z/OS system customization
System customization (also known as tailoring) is the overall process by which an
installation selects its operating system. System programmers thoroughly plan and
complete the steps in this process, selecting system options through several
different mechanisms.
System customization is accomplished through the following mechanisms:
MVS™ hardware configuration definition (HCD)
System programmers use the HCD dialog to perform a variety of tasks,
including defining the operating system and hardware configurations,
activating configuration data (that is, applying configuration changes to the
system), and querying or printing configuration data.
Initialization-time selections
When initializing the operating system, system programmers tailor the
system environment through several sources, including operator actions,
customization data in system libraries (SYS1.PARMLIB and other parmlib
data sets), and job control language (JCL) for the master scheduler
subsystem.
Implicit system parameters
Various system requirements affect the way the system performs. These
system requirements may be considered as ″implicit″ parameters. They
involve DD statements, data sets, hardware choices, and so forth. Some
examples are:
v SYSABEND, SYSMDUMP, and SYSUDUMP DD statements.
v The System Management Facilities (SMF) data sets.
v Addition of new modules to the LPALST concatenation.
v Choice of the device on which the PLPA paging data sets will reside.
v Definition of page data sets through the DEFINE PAGESPACE
command.
© Copyright IBM Corp. 2005, 2008 11
12 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 4. z/OS system libraries
The z/OS system libraries contain customization data that is essential to the
running of the z/OS system. Some of these data sets are related to IPL processing,
while others are related to the search order of invoked programs or to system
security, among other functions.
SYS1.PARMLIB
SYS1.PARMLIB is a required partitioned data set that contains control
parameters for the whole system. PARMLIB is an important data set in a
z/OS operating system, and can be thought of as performing a function
similar to /etc on a UNIX system. The purpose of PARMLIB is to provide
many control parameters in a pre-specified form in a single data set, thus
minimizing the need for the operator to enter parameters during the
initialization (IPL) process.
SYS1.PARMLIB must reside on a direct access volume, which can be the
system residence volume. Parameters are specified in both IBM-supplied
and installation-created members. All parameters and members of the
SYS1.PARMLIB data set are described in z/OS MVS Initialization and Tuning
Reference, SA22-7592.
SYS1.LINKLIB
SYS1.LINKLIB contains many of the executable code, also known as
modules, for z/OS components and utilities. By default, SYS1.LINKLIB is
the first data set in the linklist, which is a collection of libraries containing
system and user code.
One of the modules in SYS1.LINKLIB is MSTJCL00, which contains the
initial job control language (JCL) statements that start the master scheduler
subsystem. The master scheduler subsystem establishes communication
between the operating system and the primary job entry subsystem, which
is either JES2 or JES3.
System libraries for the link pack area (LPA)
The LPA is part of an address space’s common area storage, and is divided
into pageable, fixed, and modified sections:
v Libraries specified in SYS1.LPALIB, the LPALSTxx, or PROGxx parmlib
members are loaded into pageable LPA (PLPA). These libraries contain
modules for read-only system programs, along with any read-only
reenterable user programs selected by an installation that can be shared
among users of the system.
v IEAFIXxx members specify the modules loaded into fixed LPA (FLPA).
This area should be used only for modules that significantly increase
performance when they are fixed rather than pageable. The best
candidates for the FLPA are modules that are infrequently used, but are
needed for fast response. Modules placed in FLPA are always in central
storage.
v IEALPAxx members specify the modules loaded into modified LPA
(MLPA). The MLPA is used to contain reenterable routines from
APF-authorized libraries that are to be part of the pageable extension to
the link pack area during the current IPL. Note that the MLPA exists
only for the duration of an IPL.
© Copyright IBM Corp. 2005, 2008 13
Link pack area (LPA) modules are loaded in common storage, and shared
by all address spaces in the system. Because these modules are reentrant
and are not self-modifying, each can be used by a number of tasks in any
number of address spaces at the same time.
Modules placed anywhere in the LPA are always in virtual storage. To
prevent their pages from being stolen, LPA modules must be referenced
very often. When a page in LPA (other than in FLPA) is not continually
referenced by multiple address spaces, it tends to be stolen.
SYS1.PROCLIB
SYS1.PROCLIB is a required partitioned data set that contains the
IBM-supplied JCL procedures used to perform certain system functions.
The JCL can be for system tasks or for processing program tasks invoked
by the operator or the programmer.
One JCL procedure in SYS1.PROCLIB is the JES2 cataloged procedure,
which defines job-related procedure libraries.
SYS1.NUCLEUS
SYS1.NUCLEUS contains the basic supervisor modules of the system.
14 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 5. System symbols in PARMLIB
System symbols are elements that allow different z/OS systems to share PARMLIB
definitions while retaining unique values in those definitions. System symbols act
like variables in a program; they can take on different values, based on the input
to the program.
When you specify a system symbol in a shared PARMLIB definition, the system
symbol acts as a “placeholder”. Each system that shares the definition replaces the
system symbol with a unique value during initialization.
Each system symbol has a name, which begins with an ampersand (&) and
optionally ends with a period (.), and has substitution text, which is the character
string that the system substitutes for a symbol each time it appears.
There are two types of system symbols:
Dynamic
The substitution text can change at any point in an IPL.
Static The substitution text is defined at system initialization and remains fixed
for the life of an IPL.
Some symbols are reserved for system use. You can display the symbols in your
system by entering the D SYMBOLS command. Figure 3 shows the result of
entering this command.
The IEASYMxx PARMLIB member provides a single place to specify system
parameters for each system in a multisystem environment. IEASYMxx contains
statements that define static system symbols and that specify IEASYSxx PARMLIB
members that contain system parameters (the SYSPARM statement). Figure 4 on
page 16
HQX7708 ----------------- SDSF PRIMARY OPTION MENU --
COMMAND INPUT ===> -D SYMBOLS
IEA007I STATIC SYSTEM SYMBOL VALUES
&SYSALVL. = "2"
&SYSCLONE. = "70"
&SYSNAME. = "SC70"
&SYSPLEX. = "SANDBOX"
&SYSR1. = "Z17RC1"
&ALLCLST1. = "CANCEL"
&CMDLIST1. = "70,00"
&COMMDSN1. = "COMMON"
&DB2. = "V8"
&DCEPROC1. = "."
&DFHSMCMD. = "00"
&DFHSMHST. = "6"
&DFHSMPRI. = "NO"
&DFSPROC1. = "."
&DLIB1. = "Z17DL1"
&DLIB2. = "Z17DL2"
&DLIB3. = "Z17DL3"
&DLIB4. = "Z17DL4"
&IEFSSNXX. = "R7"
&IFAPRDXX. = "4A"
Figure 3. Partial output of the D SYMBOLS command (some lines removed)
© Copyright IBM Corp. 2005, 2008 15
page 16 shows an IEASYMxx PARMLIB member.
In the example, the variable &SYSNAME will have the value specified by the
SYSNAME keyword; SC70 in this case. Because each system in a sysplex has a
unique name, you can use &SYSNAME in the specification of system-unique
resources, where permitted. As an example, you could specify the name of an SMF
data set as SYS1.&SYSNAME..MAN1, with substitution resulting in the name
SYS1.SC70.MAN1 when running on SC70.
You can use variables to construct the values of other variables. In Figure 4,
&SYSCLONE takes on the value of &SYSNAME beginning at position 3 for a
length of 2. Here, &SYSCLONE will have a value of 70. Similarly, &SYSR2 is
constructed from the first 5 positions of &SYSR1 with a suffix of 2. Where is
&SYSR1 defined? &SYSR1 is system-defined with the VOLSER of the IPL volume.
If you refer back to Figure 3 on page 15, you will see the values of &SYSR1 and
&SYSR2.
Figure 4 also shows the definition of a global variable defined to all
systems--&IFAPRDXX with a value of 00--and its redefinition for SC70 to a value
of 4A.
System symbols are used in cases where multiple z/OS systems share a single
PARMLIB. The use of symbols allows individual members to be used with
symbolic substitution, as opposed to having each system require a unique member.
The LOADxx member specifies the IEASYMxx member that the system is to use.
SYSDEF SYSCLONE(&SYSNAME(3:2))
SYMDEF(&SYSR2=’&SYSR1(1:5).2’)
SYMDEF(&SYSR3=’&SYSR1(1:5).3’)
SYMDEF(&DLIB1=’&SYSR1(1:3).DL1’)
SYMDEF(&DLIB2=’&SYSR1(1:3).DL2’)
SYMDEF(&DLIB3=’&SYSR1(1:3).DL3’)
SYMDEF(&DLIB4=’&SYSR1(1:3).DL4’)
SYMDEF(&ALLCLST1=’CANCEL’)
SYMDEF(&CMDLIST1=’&SYSCLONE.,00’)
SYMDEF(&COMMDSN1=’COMMON’)
SYMDEF(&DFHSMCMD=’00’)
SYMDEF(&IFAPRDXX=’00’)
SYMDEF(&DCEPROC1=’.’)
SYMDEF(&DFSPROC1=’.’)
SYSDEF HWNAME(SCZP901)
LPARNAME(A13)
SYSNAME(SC70)
SYSPARM(R3,70)
SYMDEF(&IFAPRDXX=’4A’)
SYMDEF(&DFHSMHST=’6’)
SYMDEF(&DFHSMPRI=’NO’)
SYMDEF(&DB2=’V8’)
Figure 4. Partial IEASYMxx PARMLIB member (some lines removed)
16 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 6. Search order for programs
Modules (programs), whether stored as load modules or program objects, must be
loaded into both virtual storage and central storage before they can be run. When
one module calls another module, either directly by asking for it to be run or
indirectly by requesting a system service that uses it, it does not begin to run
instantly. How long it takes before a requested module begins to run depends on
where in its search order the system finds a usable copy and on how long it takes
the system to make the copy it finds available.
When a program is requested through a system service (like LINK, LOAD, XCTL,
or ATTACH) using default options, the system searches for it in the following
sequence:
1. Job pack area (JPA)
A program in JPA has already been loaded in the requesting address space. If
the copy in JPA can be used, it will be used. Otherwise, the system either
searches for a new copy or defers the request until the copy in JPA becomes
available. (For example, the system defers a request until a previous caller is
finished before reusing a serially-reusable module that is already in JPA.)
2. TASKLIB
A program can allocate one or more data sets to a TASKLIB concatenation.
Modules loaded by unauthorized tasks that are found in TASKLIB must be
brought into private area virtual storage before they can run. Modules that
have previously been loaded in common area virtual storage (LPA modules or
those loaded by an authorized program into CSA) must be loaded into
common area virtual storage before they can run.
3. STEPLIB or JOBLIB
These are specific DD names that can be used to allocate data sets to be
searched ahead of the default system search order for programs. Data sets can
be allocated to both the STEPLIB and JOBLIB concatenations in JCL or by a
program using dynamic allocation. However, only one or the other will be
searched for modules. If both STEPLIB and JOBLIB are allocated for a
particular jobstep, the system searches STEPLIB and ignores JOBLIB.
Any data sets concatenated to STEPLIB or JOBLIB will be searched after any
TASKLIB but before LPA. Modules found in STEPLIB or JOBLIB must be
brought into private area virtual storage before they can run. Modules that
have previously been loaded in common area virtual storage (LPA modules or
those loaded by an authorized program into CSA) must be loaded into
common area virtual storage before they can run.
4. LPA, which is searched in this order:
a. Dynamic LPA modules, as specified in PROGxx members
b. Fixed LPA (FLPA) modules, as specified in IEAFIXxx members
c. Modified LPA (MLPA) modules, as specified in IEALPAxx members
d. Pageable LPA (PLPA) modules, loaded from libraries specified in LPALSTxx
or PROGxx
LPA modules are loaded in common storage, shared by all address spaces in
the system. Because these modules are reentrant and are not self-modifying,
each can be used by any number of tasks in any number of address spaces at
the same time. Modules found in LPA do not need to be brought into virtual
storage, because they are already in virtual storage.
© Copyright IBM Corp. 2005, 2008 17
5. Libraries in the linklist, as specified in PROGxx and LNKLSTxx
By default, the linklist begins with SYS1.LINKLIB, SYS1.MIGLIB, and
SYS1.CSSLIB. However, you can change this order using SYSLIB in PROGxx
and add other libraries to the linklist concatenation. The system must bring
modules found in the linklist into private area virtual storage before the
programs can run.
The default search order can be changed by specifying certain options on the
macros used to call programs. The parameters that affect the search order the
system will use are EP, EPLOC, DE, DCB, and TASKLIB. Some IBM subsystems
(notably CICS and IMS) and applications (such as ISPF) use these facilities to
establish other search orders for programs.
18 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 7. Input/output (I/O) device configuration
The I/O configurations to the operating system (software) and the channel
subsystem (hardware) must be defined. The Hardware Configuration Definition
(HCD) component of z/OS consolidates the hardware and software I/O
configuration processes under a single interactive end-user interface.
The output of HCD is an I/O definition file (IODF), which contains I/O
configuration data. An IODF is used to define multiple hardware and software
configurations to the z/OS operating system.
When a new IODF is activated, HCD defines the I/O configuration to the channel
subsystem or the operating system, or both. With the HCD activate function or the
z/OS ACTIVATE operator command, changes can be made in the current
configuration without having to initial program load (IPL) the software or
power-on reset (POR) the hardware. Making changes while the system is running
is known as dynamic configuration or dynamic reconfiguration.
© Copyright IBM Corp. 2005, 2008 19
20 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 8. Console configuration
Operating z/OS involves managing hardware such as processors and peripheral
devices (including the consoles where your operators do their work); and software
such as the z/OS operating control system, the job entry subsystem, subsystems
(such as NetView®) that can control automated operations, and all the applications
that run on z/OS.
The operation of a z/OS system involves the following:
v Message and command processing that forms the basis of operator interaction
with z/OS and the basis of z/OS automation
v Console operations, or how operators interact with z/OS to monitor or control
the hardware and software
Planning z/OS operations for a system must take into account how operators use
consoles to do their work and how to manage messages and commands. The
system programmer needs to ensure that operators receive the necessary messages
at their consoles to perform their tasks, and select the proper messages for
suppression, automation, or other kinds of message processing.
In terms of z/OS operations, how the installation establishes console recovery or
whether an operator must re-IPL a system to change processing options are
important planning considerations.
Because messages are also the basis for automated operations, the system
programmer needs to understand message processing to plan z/OS automation.
As more installations make use of multisystem environments, the need to
coordinate the operating activities of those systems becomes crucial. Even for
single z/OS systems, an installation needs to think about controlling
communication between functional areas.
In both single and multisystem environments, the commands that operators can
enter from consoles can be a security concern that requires careful coordination. As
a planner, the system programmer needs to make sure that the right people are
doing the right tasks when they interact with z/OS.
A console configuration consists of the various consoles that operators use to
communicate with z/OS. Your installation first defines the I/O devices it can use
as consoles through the Hardware Configuration Definition (HCD), an interactive
interface on the host that allows the system programmer to define the hardware
configuration for both the channel subsystem and operating system.
Hardware Configuration Manager (HCM) is the graphical user interface to HCD.
HCM interacts with HCD in a client/server relationship (that is, HCM runs on a
workstation and HCD runs on the host). The host systems require an internal
model of their connections to devices, but it can be more convenient and efficient
for the system programmer to maintain (and supplement) that model in a visual
form. HCM maintains the configuration data as a diagram in a file on the
workstation in sync with the IODF on the host. While it is possible to use HCD
directly for hardware configuration tasks, many customers prefer to use HCM
exclusively, due to its graphical interface.
© Copyright IBM Corp. 2005, 2008 21
Besides HCD, Once the devices have been defined, z/OS is told which devices to
use as consoles by specifying the appropriate device numbers in the CONSOLxx
PARMLIB member.
Generally, operators on a z/OS system receive messages and enter commands on
MCS and SMCS consoles. They can use other consoles (such as NetView consoles)
to interact with z/OS, but here we describe the MCS, SMCS, and EMCS consoles
as they are commonly used at z/OS sites:
v Multiple Console Support (MCS) consoles are devices that are locally attached to a
z/OS system and provide the basic communication between operators and
z/OS. MCS consoles are attached to control devices that do not support systems
network architecture or SNA protocols.
v SNA Multiple Console Support (SMCS) consoles are devices that do not have to be
locally attached to a z/OS system and provide the basic communication between
operators and z/OS. SMCS consoles use z/OS Communications Server to
provide communication between operators and z/OS, instead of direct I/O to
the console device.
v Extended Multiple Console Support (EMCS) consoles are devices (other than MCS or
SMCS consoles) from which operators or programs can enter commands and
receive messages. Defining EMCS consoles as part of the console configuration
allows the system programmer to extend the number of consoles beyond the
MCS console limit, which is 99 for each z/OS system in a sysplex.
The system programmer defines these consoles in a configuration according to
their functions. Important messages that require action can be directed to the
operator, who can act by entering commands on the console. Another console can
act as a monitor to display messages to an operator working in a functional area
like a tape pool library, or to display messages about printers at your installation.
Figure 5 on page 23 shows a console configuration for a z/OS system that also
includes the system console, an SMCS console, NetView, and TSO/E.
22 z/OS Basic Skills Information Center: z/OS system installation and management
The system console function is provided as part of the Hardware Management
Console (HMC). An operator can use the system console to start up z/OS and
other system software, and during recovery situations when other consoles are
unavailable.
In addition to MCS and SMCS consoles, the z/OS system shown in Figure 5 has a
NetView console defined to it. NetView works with system messages and
command lists to help automate z/OS operator tasks. Many system operations can
be controlled from a NetView console.
Users can monitor many z/OS system functions from TSO/E terminals. Using the
System Display and Search Facility (SDSF) and the Resource Measurement Facility
(RMF?), TSO/E users can monitor z/OS and respond to workload balancing and
performance problems. An authorized TSO/E user can also initiate an extended
MCS console session to interact with z/OS.
The MCS consoles shown in Figure 5 are:
v An MCS console from which an operator can view messages and enter z/OS
commands
This console is in full capability mode because it can receive messages and
accept commands. An operator can control the operations for the z/OS system
from an MCS or SMCS console.
v An MCS status display console
An operator can view system status information from DEVSERV, DISPLAY,
TRACK, or CONFIG commands. However, because this is a status display
console, an operator cannot enter commands from the console. An operator on a
full capability console can enter these commands and route the output to a
status display console for viewing.
v An MCS message-stream console
Figure 5. Sample console configuration for a z/OS system
Chapter 8. Console configuration 23
A message-stream console can display system messages. An operator can view
messages routed to this console. However, because this is a message-stream
console, an operator cannot enter commands from here. Routing codes and
message level information for the console are defined so that the system can
direct relevant messages to the console screen for display. Thus, an operator who
is responsible for a functional area like a tape pool library, for example, can view
MOUNT messages.
In many installations, this proliferation of screens has been replaced by operator
workstations that combine many of these screens onto one windowed display.
Generally, the hardware console is separate, but most other terminals are
combined. The systems are managed by alerts for exception conditions from the
automation product.
The IBM Open Systems Adapter-Express Integrated Console Controller (OSA-ICC)
is the modern way of connecting consoles. OSA-ICC uses TCP/IP connections over
Ethernet LAN to attach to personal computers as consoles through a TN3270
connection (telnet).
24 z/OS Basic Skills Information Center: z/OS system installation and management
Part 3. Starting z/OS: The initialization (IPL) process
How often do you start or reboot the operating system for your personal computer
or notebook? Probably at least once a day, maybe more often, if you want to install
upgrades or security patches. Depending on the work you are doing, you might
reboot almost automatically, without doing more than a few save operations.
Starting z/OS is, in a very general sense, a similar process, but is done far less
frequently and only with much careful planning beforehand.
z/OS initialization, or an initial program load (IPL), is the act of loading a copy of
the operating system from disk into the processor’s real storage and executing it.
This process essentially consists of:
v System and storage initialization, including the creation of system component
address spaces
v Master scheduler initialization and subsystem initialization
z/OS systems are designed to run continuously with many months between
reloads, allowing important production workloads to be continuously available.
Change is the usual reason for a reload, and the level of change on a system
dictates the reload schedule. For example:
v A test system may be IPLed daily or even more often.
v A high-availability banking system may only be reloaded once a year, or even
less frequently, to refresh the software levels.
v Outside influences may often be the cause of IPLs, such as the need to test and
maintain the power systems in the machine room.
v Sometimes badly behaved software uses up system resources that can only be
replenished by an IPL, but this sort of behavior is normally the subject of
investigation and correction.
Many of the changes that required an IPL in the past can now be done
dynamically. Examples of these tasks are:
v Adding a library to the linklist for a subsystem such as CICS
v Adding modules to LPA
Shutting down z/OS happens as rarely as an IPL. To shut down the system, each
task must be closed in turn, in the correct order. Today’s z/OS installations use an
automation package to control and execute this process. Shutting down the system
usually requires a single command, which results in the removal of most tasks
except for the automation task itself. The automation task is closed manually,
followed by any commands needed to remove the system from a sysplex or
serialization ring.
© Copyright IBM Corp. 2005, 2008 25
26 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 9. System IPL: Sequence and key controls
The initialization process begins when the system programmer or operator selects
the LOAD function at the Hardware Management Console (HMC).
To successfully IPL z/OS, the system programmer needs to supply the following
information:
v The device address of the IPL volume
v The LOADxx member that contains pointers to system parameters
v The IODF data set that contains the configuration information
v The device address of the IODF volume
z/OS locates all usable central storage that is online and available, and begins
creating the various system areas.
Not all disks attached to a CPU have loadable code on them. A disk that does is
generally referred to as an ″IPLable″ disk, and more specifically as the SYSRES
volume.
IPLable disks contain a bootstrap module at cylinder 0 track 0. At IPL, this
bootstrap is loaded into storage at real address zero and control is passed to it. The
bootstrap then reads the IPL control program IEAIPL00 (also known as IPL text)
and passes control to it. This in turn starts the more complex task of loading the
operating system and executing it.
After the bootstrap is loaded and control is passed to IEAIPL00, IEAIPL00 prepares
an environment suitable for starting the programs and modules that make up the
operating system, as follows:
1. It clears central storage to zeros before defining storage areas for the master
scheduler.
2. It locates the SYS1.NUCLEUS data set on the SYSRES volume and loads a
series of programs from it known as IPL Resource Initialization Modules
(IRIMs).
Figure 6. IPLing the machine
© Copyright IBM Corp. 2005, 2008 27
3. These IRIMs begin creating the normal operating system environment of
control blocks and subsystems.
Some of the more significant tasks performed by the IRIMs are as follows:
v Read the LOADPARM information entered on the hardware console at the time
the IPL command was executed.
v Search the volume specified in the LOADPARM member for the IODF data set.
IRIM will first attempt to locate LOADxx in SYS0.IPLPARM. If this is
unsuccessful, it will look for SYS1.IPLPARM, and so on, up to and including
SYS9.IPLPARM. If at this point it still has not been located, the search continues
in SYS1.PARMLIB. (If LOADxx cannot be located, the system loads a wait state.)
v If a LOADxx member is found, open and read information including the nucleus
suffix (unless overridden in LOADPARM), the master catalog name, and the
suffix of the IEASYSxx member to be used.
v Load the operating system’s nucleus.
v Initialize virtual storage in the master scheduler address space for the System
Queue Area (SQA), the Extended SQA (ESQA), the Local SQA (LSQA), and the
Prefixed Save Area (PSA). At the end of the IPL sequence, the PSA will replace
IEAIPL00 at real storage location zero, where it will then stay.
v Initialize real storage management, including the segment table for the master
scheduler, segment table entries for common storage areas, and the page frame
table.
The last of the IRIMs then loads the first part of the Nucleus Initialization Program
(NIP), which invokes the Resource Initialization Modules (RIMs), one of the
earliest of which starts up communications with the NIP console defined in the
IODF.
During the NIP stage, the system might prompt the system programmer or
operator to provide system parameters that control the operation of z/OS. The
system also issues informational messages about the stages of the initialization
process. IEASYSnn, a member of PARMLIB, contains parameters and pointers that
control the direction that the IPL takes. The system programmer or operator may
alter these parameters as necessary.
IEASYSnn, a member of PARMLIB, contains parameters and pointers that control
the direction that the IPL takes. Figure 7 on page 29 illustrates partial content of an
IEASYSxx member.
28 z/OS Basic Skills Information Center: z/OS system installation and management
The system continues the initialization process, interpreting and acting on the
system parameters that were specified. NIP carries out the following major
initialization functions:
v Expands the SQA and the extended SQA by the amounts specified on the SQA
system parameter.
v Creates the pageable link pack area (PLPA) and the extended PLPA for a cold
start IPL; resets tables to match an existing PLPA and extended PLPA for a quick
start or a warm start IPL.
v Loads modules into the fixed link pack area (FLPA) or the extended FLPA. Note
that NIP carries out this function only if the FIX system parameter is specified.
v Loads modules into the modified link pack area (MLPA) and the extended
MLPA. Note that NIP carries out this function only if the MLPA system
parameter is specified.
v Allocates virtual storage for the common service area (CSA) and the extended
CSA. The amount of storage allocated depends on the values specified on the
CSA system parameter at IPL.
v Page-protects the NUCMAP, PLPA and extended PLPA, MLPA and extended
MLPA, FLPA and extended FLPA, and portions of the nucleus. An installation
can override page protection of the MLPA and FLPA by specifying NOPROT on
the MLPA and FIX system parameters.
To see information on how your system was IPLed, you can issue the D IPLINFO
command, as Figure 8 on page 30 shows.
----------------------------------------------------------------------------
File Edit Edit_Settings Menu Utilities Compilers Test Help
-------------------------------------------------------------------------------
EDIT SYS1.PARMLIB(IEASYS00) - 01.68 Columns 00001 00072
Command ===> Scroll ===> CSR
*********************************** Top of Data ******************************
000001 ALLOC=00,
000002 APG=07,
000003 CLOCK=00,
000004 CLPA,
000005 CMB=(UNITR,COMM,GRAPH,CHRDR),
000006 CMD=(&CMDLIST1.),
000007 CON=00,
000008 COUPLE=00, WAS FK
000009 CSA=(2M,128M),
000010 DEVSUP=00,
000011 DIAG=00,
000012 DUMP=DASD,
000013 FIX=00,
000014 GRS=STAR,
000015 GRSCNF=ML,
000016 GRSRNL=02,
000017 IOS=00,
000018 LNKAUTH=LNKLST,
000019 LOGCLS=L,
000020 LOGLMT=999999,
000021 LOGREC=SYS1.&SYSNAME..LOGREC,
000022 LPA=(00,L),
000023 MAXUSER=1000,
000024 MSTRJCL=00,
000025 NSYSLX=250,
000026 OMVS=&OMVSPARM.,
Figure 7. Partial listing of IEASYS00 member
Chapter 9. System IPL: Sequence and key controls 29
D IPLINFO
IEE254I 11.11.35 IPLINFO DISPLAY 906
SYSTEM IPLED AT 10.53.04 ON 08/15/2007
RELEASE z/OS 01.07.00 LICENSE = z/OS
USED LOADS8 IN SYS0.IPLPARM ON C730
ARCHLVL = 2 MTLSHARE = N
IEASYM LIST = XX
IEASYS LIST = (R3,65) (OP)
IODF DEVICE C730
IPL DEVICE 8603 VOLUME Z17RC1
Figure 8. Output of the D IPLINFO command
30 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 10. System IPL: Address space creation and
subsystem initialization
In addition to initializing system areas, z/OS establishes system component
address spaces. It establishes an address space for the master scheduler and other
system address spaces for various subsystems and system components. Some of
the component address spaces are: *MASTER*, ALLOCAS, APPC, CATALOG, and
so on.
The master scheduler address space is the first system component address space to
be created (ASID=1). Then, the master scheduler may start the primary job entry
subsystem (JES2 or JES3). On many production systems, JES is not started
immediately; instead, an automation package starts all tasks in a controlled
sequence.
Then other defined subsystems are started. All subsystems are defined in the
PARMLIB library, in member IEFSSNxx. These subsystems are secondary subsystems.
Figure 9 shows some of the important system component address spaces; for
started tasks VTAM®, CICS, TSO; and for a TSO user and a batch initiator. Each
address space has 2 GB of virtual storage by default, whether the system is
running in 31-bit or 64-bit mode.
The private areas are available only to that address space, but common areas are
available to all.
After the system is initialized and the job entry subsystem is active, the installation
can submit jobs for processing by using the START, LOGON, or MOUNT
command. When a job is activated through START (for batch jobs), LOGON (for
time-sharing jobs), or MOUNT, a new address space is allocated.
The master scheduler subsystem
The master scheduler subsystem establishes communication between the operating
system and the primary job entry subsystem, which can be JES2 or JES3.
Figure 9. Virtual storage layout for multiple address spaces
© Copyright IBM Corp. 2005, 2008 31
To do its work, the master scheduler subsystem uses an MSTJCLxx member,
commonly called master JCL, which contains data definition (DD) statements for all
system input and output data sets that are needed to do the communication
between the operating system and JES.
An initial MSTJCL00 load module can be found in the SYS1.LINKLIB library. As
shipped, MSTJCL00 contains an IEFPDSI DD statement that defines the data set
that contains procedure source JCL for started tasks. Normally this data set is
SYS1.PROCLIB; it may be a concatenation. For useful work to be performed,
SYS1.PROCLIB must at least contain the procedure for the primary JES.
If modifications are required, the recommended procedure is to create an
MSTJCLxx member in the PARMLIB data set. The suffix is specified by the
MSTRJCL parameter in the IEASYSxx member of PARMLIB.
Figure 10 shows a sample MSTJCLxx member.
When the master scheduler has to process the start of a started task, the system
determines whether the START command refers to a procedure or to a job. If the
IEFJOBS DD exists in the MSTJCLxx member, the system searches the IEFJOBS DD
concatenation for the member requested in the START command.
If there is no member by that name in the IEFJOBS concatenation, or if the
IEFJOBS concatenation does not exist, the system searches the IEFPDSI DD for the
member requested in the START command. If a member is found, the system
examines the first record for a valid JOB statement and, if one exists, uses the
member as the JCL source for the started task. If the member does not have a valid
JOB statement in its first record, the system assumes that the source JCL is a
procedure and creates JCL to invoke the procedure. After the JCL source has been
created (or found), the system processes the JCL.
As shipped, MSTJCL00 contains an IEFPDSI DD statement that defines the data set
that contains procedure source JCL for started tasks. Normally this data set is
SYS1.PROCLIB; it may be a concatenation. For useful work to be performed,
SYS1.PROCLIB must at least contain the procedure for the primary JES.
The job entry subsystem (JES)
For useful work to be performed on z/OS, SYS1.PROCLIB must contain a job
procedure for the primary job entry subsystem.
File Edit Edit_Settings Menu Utilities Compilers Test Help
-------------------------------------------------------------------------------
EDIT SYS1.PARMLIB(MSTJCL00) - 01.07 Columns 00001 00072
Command ===> Scroll ===> CSR
*********************************** Top of Data ******************************
000100 //MSTRJCL JOB MSGLEVEL=(1,1),TIME=1440
000200 // EXEC PGM=IEEMB860,DPRTY=(15,15)
000300 //STCINRDR DD SYSOUT=(A,INTRDR)
000400 //TSOINRDR DD SYSOUT=(A,INTRDR)
000500 //IEFPDSI DD DSN=SYS1.PROCLIB,DISP=SHR
000600 // DD DSN=CPAC.PROCLIB,DISP=SHR
000700 // DD DSN=SYS1.IBM.PROCLIB,DISP=SHR
000800 //IEFJOBS DD DSN=SYS1.STCJOBS,DISP=SHR
000900 //SYSUADS DD DSN=SYS1.UADS,DISP=SHR
********************************** Bottom of Data ****************************
Figure 10. Sample master JCL
32 z/OS Basic Skills Information Center: z/OS system installation and management
To initialize JES, the master scheduler subsystem looks in SYS1.PROCLIB for the
JES cataloged procedure. This procedure defines the job-related procedure libraries,
including those that the JES subsystem uses to locate the JES initialization
statements. A sample job procedure library is shown in Figure 11.
Many installations have very long lists of procedure libraries in the JES procedure.
Care should be taken as to the number of users who can delete these libraries
because JES will not start if one is missing. Normally a library that is in use cannot
be deleted, but JES does not hold these libraries although it uses them all the time.
You can override the default specification by specifying this statement: /*JOBPARM
PROCLIB=
After the name of the procedure library, you code the name of the DD statement in
the JES2 procedure that points to the library to be used. For example, in Figure 11,
assume that you run a job in class A and that class has a default PROCLIB
specification on PROC00. If you want to use a procedure that resides in
SYS1.LASTPROC, you’ll need to include this statement in the JCL:/*JOBPARM
PROCLIB=PROC99
Another way to specify a procedure library is to use the JCLLIB JCL statement.
This statement allows you to code and use procedures without using system
procedure libraries. The system searches the libraries in the order in which you
specify them on the JCLLIB statement, prior to searching any unspecified default
system procedure libraries.
Figure 12 shows the use of the JCLLIB statement.
Assuming that the system default procedure library includes SYS1.PROCLIB only,
the system searches the libraries for procedure MYPROC1 in the following order:
1. MY.PROCLIB.JCL
2. SECOND.PROCLIB.JCL
3. SYS1.PROCLIB
Initialization of additional subsystems
Subsystem initialization is the process of readying a subsystem for use in the
system. IEFSSNxx members of SYS1.PARMLIB contain the definitions for the
primary subsystems such as JES2 or JES3, and the secondary subsystems such as
NetView and DB2.
During system initialization, the defined subsystems are initialized. You should
define the primary subsystem (JES) first because other subsystems, such as DB2,
//PROC00 DD DSN=SYS1.PROCLIB,DISP=SHR
// DD DSN=SYS3.PROD.PROCLIB,DISP=SHR
//PROC01 DD DSN=SYS1.PROC2,DISP=SHR
...
//PROC99 DD DSN=SYS1.LASTPROC,DISP=SHR
...
Figure 11. Job procedure libraries in the JES2 procedure
//MYJOB JOB
//MYLIBS JCLLIB ORDER=(MY.PROCLIB.JCL,SECOND.PROCLIB.JCL)
//S1 EXEC PROC=MYPROC1
...
Figure 12. Sample JCLLIB statement
Chapter 10. System IPL: Address space creation and subsystem initialization 33
require the services of the primary subsystem in their initialization routines.
Problems can occur if subsystems that use the subsystem affinity service in their
initialization routines are initialized before the primary subsystem. After the
primary JES is initialized, the subsystems are initialized in the order in which the
IEFSSNxx PARMLIB members are specified by the SSN parameter. For example,
for SSN=(aa,bb), PARMLIB member IEFSSNaa would be processed before
IEFSSNbb.
34 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 11. System IPL: Description of IPL types
Depending on the circumstances under which you want to start or restart z/OS,
you may use one of three types of initialization: Cold start, quick start, or warm
start.
The primary difference between the three types is whether or not certain storage is
treated.
Cold start
An IPL that loads (or reloads) the pageable link pack area (PLPA) and
clears the virtual input/output (VIO) data set pages.
The first IPL after system installation is always a cold start because the
PLPA is initially loaded. Subsequent IPLs are cold starts when the PLPA is
reloaded, either to alter its contents or to restore its contents if they were
lost. This is usually done when changes have been made to the LPA (for
example, when a new SYSRES containing maintenance is being loaded).
VIO is a method of using memory to store small temporary data sets for
rapid access. However, unlike a RAM disk on a PC, these are actually
backed up to disk and so can be used as a restart point. Obviously there
should not be too much data stored in this way, so the size is restricted.
Quick start
An IPL that does not reload the PLPA, but clears the VIO data set pages.
(The system resets the page and segment tables to match the last-created
PLPA.) This is usually done when there have been no changes to LPA, but
VIO must be refreshed. This prevents the warm start of jobs that were
using VIO data sets.
Warm start
An IPL that does not reload the PLPA, and preserves journaled VIO data
set pages. This will allow jobs that were running at the time of the IPL to
restart with their journaled VIO data sets.
Often, the preferred approach is to do a cold start IPL (specifying CLPA). The other
options can be used, but extreme care must be taken to avoid unexpected change
or backout of change. A warm start could be used when you have long-running
jobs which you want to restart after IPL, but an alternative approach is to break
down those jobs into smaller pieces which pass real data sets rather than use VIO.
Modern disk controllers with large cache memory have reduced the need for VIO
data to be kept for long periods.
Also, do not confuse a cold start IPL (CLPA would normally be used rather than
the term ″cold start″) with a JES cold start. Cold starting JES is something that is
done extremely rarely, if ever, on a production system, and totally destroys the
existing data in JES.
© Copyright IBM Corp. 2005, 2008 35
36 z/OS Basic Skills Information Center: z/OS system installation and management
Part 4. z/OS system tuning
The task of ″tuning″ a system is an iterative and continuous process, and it is the
discipline that most directly impacts all users of system resources in an enterprise.
The z/OS Workload Management (WLM) component is an important part of this
process and includes initial tuning of selecting appropriate parameters for various
system components and subsystems.
After the system is operational and criteria have been established for the selection
of jobs for execution through job classes and priorities, WLM controls the
distribution of available resources according to the parameters specified by the
installation.
WLM, however, can deal with only available resources. If these are inadequate to
meet the needs of the installation, even optimal distribution may not be the
answer; other areas of the system should be examined to determine the possibility
of increasing available resources. When requirements for the system increase and it
becomes necessary to shift priorities or acquire additional resources (such as a
larger processor, more storage, or more terminals), the system programmer needs
to modify WLM parameters to reflect changed conditions.
© Copyright IBM Corp. 2005, 2008 37
38 z/OS Basic Skills Information Center: z/OS system installation and management
Part 5. z/OS software maintenance
As a z/OS system programmer, it will be your responsibility to ensure that all
software products and their modifications are properly installed on the system.
You will also have to ensure that all products are installed at the proper level so
that the elements of the system can work together.
At first, that might not sound too difficult, but as the complexity of the software
configuration increases, so, too, does the task of monitoring all the elements of the
system. Data center management is typically held accountable for Service Level
Agreements (SLAs), often through a specialist team of service managers. Change
control mechanics and practices in a data center are implemented to ensure that
SLAs are met.
System Modification Program Extended (SMP/E) is the primary means of
installing and updating the software in a z/OS system. SMP/E consolidates
installation data, allows more flexibility in selecting changes to be installed,
provides a dialog interface, and supports dynamic allocation of data sets. SMP/E
can be run either using batch jobs or using dialogs under Interactive System
Productivity Facility/Program Development Facility (ISPF/PDF). With SMP/E
dialogs, you can interactively query the SMP/E database and create and submit
jobs to process SMP/E commands.
Software to be installed by SMP/E must be packaged as system modifications or
SYSMODs, which combine the updated element with control information. This
information describes the elements and any relationships the software has with
other products or service that may also be installed on the same system.
The SMP/E job control language (JCL) and commands will be used frequently by a
large enterprise z/OS system programmer, however, SMP/E modification control
statement (MCS) instructions will rarely be coded by the same system programmer.
The product and SYSMOD packaging will include the necessary MCS statements.
A critical responsibility of the system programmer is to work with IBM defect
support when a problem surfaces in z/OS or optional IBM products. Problem
resolution requires the system programmer to receive and apply fixes to the
enterprise system.
© Copyright IBM Corp. 2005, 2008 39
40 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 12. z/OS conventions: Following a process of change
control
One of the advantages of the mainframe is the very high availability that it offers;
therefore, all change must therefore be carefully controlled and managed. A high
proportion of any system programmer’s time is involved in the planning and risk
assessment of change. One of the most important aspects of change is how to
reverse it and go back to the previous state.
The implementation of any change must be under the control of the Operations
staff. When a change is introduced into a production environment that results in
problems or instability, Operations staff are responsible for observing, reporting,
and then managing the activities required to correct the problem or back out the
change.
Although system programmers will normally originate and implement their own
changes, sometimes changes are based on a request through the change
management system. Any instructions for Operations or other groups would be in
the change record, and the approval of each group is required.
Implementing business application changes would normally be handled by a
production control analyst. Application changes will normally reside in test
libraries, and an official request (with audit trail) would result in the programs in
the test libraries being promoted to the production environment.
Procedures involved in the change must be circulated to all interested parties.
When all parties consider the change description to be complete, then it is
considered for implementation and either scheduled, deferred, or possibly rejected.
The factors that need to be considered when planning a change are:
v The benefits that will result from the change
v What will happen if the change is not done
v The resources required to implement the change
v The relative importance of the change request compared to others
v Any interdependency of change requests
Risk assessment
It is common practice for data center management to have a weekly change control
meeting to discuss, approve, or reject changes. These changes might be for
applications, a system, a network, hardware, or power.
An important part of any change is risk assessment, in which the change is
considered and evaluated from the point of view of risk to the system. Low risk
changes may be permitted during the day, while higher risk changes would be
scheduled for an outage slot.
It is also common practice for a data center to have periods of low and high risk,
which will influence decisions. For example, if the system runs credit
authorizations, then the periods around major public holidays are usually
© Copyright IBM Corp. 2005, 2008 41
extremely busy and may cause a change freeze. Also, annual sales are extremely
busy periods in retailing and may cause changes to be rejected.
IT organizations achieve their goals through disciplined change management
processes and policy enforcement. These goals include:
v High service availability
v Increased security
v Audit readiness
v Cost savings
Change control record system
A change control record system is typically in place to allow for the requesting,
tracking, and approval of changes. This is usually the partner of a problem
management system. For example, if a production system has a serious problem on a
Monday morning, then one of the first actions will be to examine the changes that
were implemented over the weekend to determine if these have any bearing on the
problem.
These records also show that the system is under control, which is often necessary
to prove to auditors, especially in the heavily regulated financial services sector.
The Sarbanes-Oxley Act of 2002 in the United States, which addresses corporate
governance, has established the need for an effective internal control system.
Demonstrating strong change management and problem management in IT
services is part of compliance with this measure. Additionally, the 8th Directive on
Company Law in the European Union addresses similar areas to Sarbanes-Oxley.
For these reasons, and at a bare minimum, before any change is implemented,
there should be a set of controlled documents defined, which are known as change
request forms. These should include the following:
v Who is responsible for implementing the change, completing the successful test
and responsible for backout if required. Also who will ″sign off″ the change as
successful. This is usually a department, group or person that requires the
change.
v What are the affected systems or services (for example e-mail, file service,
domain, and so on). Include as much detail as possible. Ideally, complete
instructions should be included so that the change could be performed by
someone else in an emergency.
v The start date and time and estimated duration of the change. There are often
three dates: requested, scheduled. and actual.
v The scope of change, the business units, buildings, departments or groups
affected or required to assist with the change.
v The implementation plan and a plan for backing off the changes, if the need
arises.
v The priority of the change; that is, high, medium, low, business as usual,
emergency, dated (for example clock change).
v The risk, which is usually classified as high, medium, or low.
v The impact if the change is implemented; what will happen if it is not; what
other systems may be affected; what will happen if something unexpected
occurs.
42 z/OS Basic Skills Information Center: z/OS system installation and management
Production control
Production control usually involves a specialized staff to manage batch scheduling,
using a tool such as Tivoli® Workload Scheduler to build and manage a complex
batch schedule. This work might involve daily and weekly backups running at
particular points within a complex sequence of application suites. Databases and
online services might also be taken down and brought back up as part of the
schedule. While making such changes, production control often needs to
accommodate public holidays and other special events such as (in the case of a
retail sales business) a winter sale.
Production control is also responsible for taking a programmer’s latest program
and releasing it to production. This task typically involves moving the source code
to a secure production library, recompiling the code to produce a production load
module, and placing that module in a production load library. JCL is copied and
updated to production standards and placed in appropriate procedure libraries,
and application suites added to the job scheduler.
There might also be an interaction with the system programmer if a new library
needs to be added to the linklist, or authorized.
Chapter 12. z/OS conventions: Following a process of change control 43
44 z/OS Basic Skills Information Center: z/OS system installation and management
Chapter 13. System installation and maintenance using SMP/E
System Modification Program Extended (SMP/E) is the z/OS tool for managing
the installation of software products on a z/OS system and for tracking
modifications to those products.
SMP/E controls these changes at the component level by:
v Selecting the proper levels of code to be installed from a large number of
potential changes.
v Calling system utility programs to install the changes.
v Keeping records of the installed changes by providing a facility to enable you to
inquire on the status of your software, and to reverse the change if necessary.
All code and its modifications are located in the SMP/E database called the
consolidated software inventory (CSI), which is comprised of one or more VSAM
data sets.
SMP/E can be run either using batch jobs or using dialogs under ISPF/PDF. With
SMP/E dialogs, you can interactively query the SMP/E database and create and
submit jobs to process SMP/E commands.
The SMP/E view of the system
A z/OS system might appear to be one big block of code that drives the CPU.
Actually, z/OS is a complex system comprising many different smaller blocks of
code, and that’s how SMP/E sees z/OS.
Each of those smaller blocks of code perform a specific function within the system.
Functions that can appear in a z/OS system (some of which are shown in
Figure 13 on page 46) include:
v Base Control Program (BCP)
v Job entry subsystem (JES2 or JES3)
v Time Sharing Option/Extensions (TSO/E)
v Interactive System Productivity Facility (ISPF)
v System Display and Search Facility (SDSF)
v Data Facility Storage Management Subsystem (DFSMS)
v System Modification Program Extended (SMP/E)
v z/OS UNIX System Services (z/OS UNIX)
v Resource Measurement Facility (RMF)
v HTTP Server
v DB2 (Database 2™)
v Customer Information Control System (CICS)
v WebSphere MQ
© Copyright IBM Corp. 2005, 2008 45
Each system function is composed of one or more load modules. In a z/OS
environment, a load module represents the basic unit of machine-readable,
executable code. Load modules are created by combining one or more object
modules and processing them with a link-edit utility. The link-editing of modules
is a process that resolves external references and addresses. The functions on your
system, therefore, are one or more object modules that have been combined and
link-edited.
To see where the object module comes from, look at the example in Figure 14.
Most of the time, object modules are sent to you as part of a product. In this
example, the object module MOD1 was sent as part of the product. Other times,
you might need to assemble source code sent to you by product packagers to
create the object module. You can modify the source code and then assemble it to
produce an object module. In the example, SRCMOD2 is source code that you
assemble to create object module MOD2. When assembled, you link-edit object
module MOD2 with object module MOD1 to form the load module LMOD1.
In addition to object modules and source code, most products distribute many
other parts, such as macros, help-panels, CLISTs and other z/OS library members.
These modules, macros and other types of data and code are the basic building
blocks of your system. All of these building blocks are called elements.
Elements are associated with, and depend upon, other products or services that
may be installed on the same z/OS system. They describe the relationship the
software has with other products or services that may be installed on the same
z/OS system.
Figure 13. SMP/E view of the system
Figure 14. Load module creation
46 z/OS Basic Skills Information Center: z/OS system installation and management
How the SMP/E environment is similar to a public library
To properly perform its processing, SMP/E must maintain a great deal of
information about the structure, content, and modification status of the software it
manages. Think of all the information SMP/E has to maintain as if it were all the
information contained in the public library.
In a public library, you see bookshelves filled with books and a card catalog with
drawers containing a card for each book in the library. These cards contain
information, such as the title, author, publishing dates, type of book, and a pointer
to the actual book on the shelf.
In the SMP/E environment, there are two distinct types of ″bookshelves.″ They are
referred to as the distribution libraries and the target libraries. In much the same
way the bookshelves in the public library hold the library books, the distribution
and target libraries hold the elements of the system.
Distribution libraries contain all the elements, such as modules and macros, that are
used as input for running your system. One very important use of the distribution
libraries is for backup. Should a serious error occur with an element on the
production system, the element can be replaced by a stable level found in the
distribution libraries.
Target libraries contain the executable code needed to run your system (for example,
the libraries from which you run your production system or your test system).
As you think of the analogy of the public library, you can see that there is one
important piece of that picture that we have not yet considered. In the public
library, there is a card catalog to help you find the book or piece of information
you are looking for. SMP/E provides the same type of tracking mechanism in the
form of the consolidated software inventory (CSI).
The CSI data sets contain all the information SMP/E needs to track the distribution
and target libraries. As the card catalog contains a card for each book in the library,
the CSI contains an entry for each element in its libraries. The CSI entries contain
the element name, type, history, how the element was introduced into the system,
and a pointer to the element in the distribution and target libraries. The CSI does
not contain the element itself, but rather a description of the element it represents.
The cards in the public library card catalog are arranged alphabetically by the
author’s last name, and by the topic and title of the book. In the CSI, entries for
the elements in the distribution and target libraries are grouped according to their
installation status. That is, entries representing elements found in the distribution
libraries are contained in the distribution zone. Entries representing elements found
in the target libraries are contained in the target zone. Both of these zones serve
the same purpose as the drawers of the public library card catalog.
In addition to the distribution and target zones, the SMP/E CSI also contains a
global zone. Figure 15 on page 48 shows the relationship between SMPE zones and
libraries.
Chapter 13. System installation and maintenance using SMP/E 47
The global zone contains:
v Entries needed to identify and describe each target and distribution zone to
SMP/E
v Information about SMP/E processing options
v Status information for all system modifications (known as SYSMODs) that
SMP/E has begun to process
v Exception data for SYSMODs requiring special handling or that are in error.
In SMP/E, the term exception data usually refers to HOLDDATA. HOLDDATA is
often supplied for a product to indicate a specified SYSMOD should be held from
installation. Reasons for holding a SYSMOD can be:
v A PTF is in error and should not be installed until the error is corrected (ERROR
HOLD).
v Certain system actions may be required before SYSMOD installation (SYSTEM
HOLD).
v The user may want to perform some actions before installing the SYSMOD
(USER HOLD).
All the information located in the global zone, combined with the information
found in the target and distribution zones, make up the data that SMP/E requires
to install and track the system’s software, which is often a great deal of data. You
can display this information using the following SMP/E facilities:
v Query dialogs: The easiest and fastest way to obtain just the information you
want
v LIST command: When you need an all-inclusive hardcopy listing of information
about your system
v REPORT commands: To check and compare the zone contents and generate
command output that can be used to update your system
v SMP/E CSI application programming interface: To write an application program
to query the contents of your system’s CSI data sets.
SMP/E data sets for inventory, zones, and libraries
To install z/OS elements in target and distribution libraries, SMP/E uses a
database made up of several types of data sets.
Figure 15. Relationship between SMP/E zones and libraries
48 z/OS Basic Skills Information Center: z/OS system installation and management
SMPCSI (CSI) data sets
SMPCSI (CSI) data sets are VSAM data sets used to control the installation
process and record the results of processing. A CSI can be divided into
multiple partitions through the VSAM key structure. Each partition is
referred to as a zone.
There are three types of zones:
v A single global zone is used to record information about SYSMODs that
have been received into the SMPPTS data set. The global zone also
contains information enabling SMP/E to access the other two types of
zones, information about system utilities that SMP/E calls to install
elements from SYSMODs, and information allowing you to tailor SMP/E
processing.
v One or more target zones are used to record information about the
status and structure of the operating system (or target) libraries. Each
target zone also points to the related distribution zone, which can be
used during APPLY, RESTORE, and LINK when SMP/E is processing a
SYSMOD and needs to check the level of the elements in the distribution
libraries.
v One or more distribution zones are used to record information about
the status and structure of the distribution libraries (DLIBs). Each DLIB
zone also points to the related target zone, which is used when SMP/E
is accepting a SYSMOD and needs to check if the SYSMOD has already
been applied.
There can be more than one zone in an SMPCSI data set (in fact, there can
be up to 32766 zones per data set). For example, an SMPCSI data set can
contain a global zone, several target zones, and several distribution zones.
The zones can also be in separate SMPCSI data sets. One SMPCSI data set
can contain just the global zone, a second SMPCSI data set the target
zones, and a third SMPCSI data set the distribution zones.
SMPPTS (PTS) data set
An SMPPTS (PTS) data set is a data set for temporary storage of SYSMODs
waiting to be installed. The PTS is used strictly as a storage data set for
SYSMODs. The RECEIVE command stores SYSMODs directly on the PTS
without any modifications of SMP/E information. The PTS is related to the
global zone in that both data sets contain information about the received
SYSMODs. Only one PTS can be used for a given global zone. Therefore,
you can look at the global zone and the PTS as a pair of data sets that
must be processed (for example, deleted, saved, or modified) concurrently.
SMPSCDS (SCDS) data set
The SMPSCDS (SCDS) data set contains backup copies of target zone
entries modified during APPLY processing. Therefore, each SCDS is
directly related to a specific target zone, and each target zone must have its
own SCDS. SCDS data sets are used by SMP/E to store backup copies of
target zone entries modified during APPLY processing. Therefore, each
SCDS is directly related to a specific target zone, and each target zone
must have its own SCDS.
SMP/E also uses the following data sets:
v The SMPMTS (MTS) data set is a library in which SMP/E stores copies of
macros during installation when no other target macro library is identified.
Therefore, the MTS is related to a specific target zone, and each target zone must
have its own MTS data set.
Chapter 13. System installation and maintenance using SMP/E 49
v The SMPSTS (STS) data set is a library in which SMP/E stores copies of source
during installation when no other target source library is identified. Therefore,
the STS is related to a specific target zone, and each target zone must have its
own STS data set.
v The SMPLTS (LTS) data set is a library that maintains the base version of a load
module. The load module in this library specifies a SYSLIB allocation in order to
implicitly include modules. Therefore, the LTS is related to a specific target zone,
and each target zone must have its own LTS data set.
v Other utility and work data sets.
SMP/E uses information in the CSI data sets to select proper element levels for
installation, to determine which libraries should contain which elements, and to
identify which system utilities should be called for the installation.
System programmers can also use the CSI data sets to obtain the latest information
on the structure, content, and status of the system. SMP/E provides this
information in reports, listings, and dialogs to help you:
v Investigate function and service levels
v Understand intersections and relationships of SYSMODs (either installed or
waiting to be installed)
v Build job streams for SMP/E processing.
Figure 16 shows sample job control language (JCL) for creating the CSI data sets.
What is a SYSMOD?
SMP/E can install a large variety of system updates, provided they are packaged
as a system modification or SYSMOD. A SYSMOD is the actual package of
elements and control information that SMP/E needs to install and track system
modifications.
//DEFINE JOB ’accounting info’,MSGLEVEL=(1,1)
//STEP01 EXEC PGM=IDCAMS
//CSIVOL DD UNIT=3380,VOL=SER=volid,DISP=SHR
//SYSPRINT DD SYSOUT=A
//SYSIN DD *
DEFINE CLUSTER( -
NAME(SMPE.SMPCSI.CSI) -
FREESPACE(10 5) -
KEYS(24 0) -
RECORDSIZE(24 143) -
SHAREOPTIONS(2 3) -
VOLUMES(volid1) -
) -
DATA( -
NAME(SMPE.SMPCSI.CSI.DATA) -
CONTROLINTERVALSIZE(4096) -
CYLINDERS(250 20) -
) -
INDEX( -
NAME(SMPE.SMPCSI.CSI.INDEX) -
CYLINDERS(5 3) -
) -
CATALOG(user.catalog)
/*
Figure 16. JCL for defining a CSI VSAM data sets
50 z/OS Basic Skills Information Center: z/OS system installation and management
SYSMODs are composed of a combination of elements and control information.
They are comprised of two parts, as follows:
v Modification control statements (MCSs), designated by ++ as the first two
characters, that tell SMP/E:
v What elements are being updated or replaced
v How the SYSMOD relates to product software and other SYSMODs
v Other specific installation information
v Modification text, which is the object modules, macros, and other elements
supplied by the SYSMOD
There are four different categories of SYSMODs, each supporting a task you might
want to perform:
FUNCTION
This type of SYSMOD introduces a new product, a new version or release
of a product, or updated functions for an existing product into the
system.This type of SYSMOD introduces a new product, a new version or
release of a product, or updated functions for an existing product into the
system.
PTF A program temporary fix (PTF) is an IBM-supplied correction for a reported
problem. They are meant to be installed in all environments. PTFs may be
used as preventive service to avoid certain known problems that may have
not yet appeared on your system, or they may be used as corrective service
to fix problems you have already encountered. The installation of a PTF
must always be preceded by that of a function SYSMOD, and often other
PTFs as well.
APAR An authorized program analysis report (APAR) is a temporary fix designed to
correct or bypass a problem for the first reporter of the problem. An APAR
might not be applicable to your environment. The installation of an APAR
must always be preceded by that of a function SYSMOD, and sometimes of
a particular PTF. That is, an APAR is designed to be installed on a
particular preventive-service level of an element.
USERMOD
This type of SYSMOD is created by you, either to change IBM code or to
add independent functions to the system. The installation of a USERMOD
must always be preceded by that of a function SYSMOD, sometimes
certain PTFs, APAR fixes, or other USERMODs.
SMP/E keeps track of the functional and service levels of each element and uses
this SYSMOD hierarchy to determine such things as which functional and service
levels of an element should be installed and the correct order for installing updates
for elements.
Function SYSMOD: Introducing an element in the system
One way you can modify your system is to introduce new elements into that
system. To accomplish this with SMP/E, you can install a function SYSMOD.
The function SYSMOD introduces a new product, a new version or release of a
product, or updated functions for an existing product into the system. All other
types of SYSMODs are dependent upon the function SYSMOD, because they are all
modifications of the elements originally introduced by the function SYSMOD.
Chapter 13. System installation and maintenance using SMP/E 51
When introducing a function SYSMOD, all of the element’s components or code
are placed in the system data sets, or libraries. Examples of these libraries are
SYS1.LPALIB, SYS1.MIGLIB, and SYS1.SVCLIB.
Figure 17 shows the process of creating executable code in the production system
libraries.
In Figure 17, the installation of a function SYSMOD link-edits object modules
MOD1, MOD2, MOD3, and MOD4 to create load module LMOD2. The executable
code created in load module LMOD2 is installed in the system libraries through
the installation of the function SYSMOD.
There are two types of function SYSMODs:
v A base function SYSMOD adds or replaces an entire system function. Examples
of base functions are SMP/E and JES2.
v A dependent function SYSMOD provides an addition to an existing system
function. It is called dependent because its installation depends upon a base
function already being installed. Examples of dependent functions are the
language features for SMP/E.
Both base function SYSMODs and dependent function SYSMODs are used to
introduce new elements into the system. Figure 18 shows an example of a simple
function SYSMOD that introduces four elements.
PTF SYSMOD: Preventing or fixing problems with an element
When a problem with a software element is discovered, IBM supplies its customers
with a tested fix for that problem. This fix comes in the form of a program
temporary fix (PTF). Although you may not have experienced the problem the PTF
MOD1
MOD2
MOD3
MOD4
System libraries
LMOD2
Link editMOD1
MOD2
MOD3
MOD4
FunctionSYSMOD
ZO
SB
046-0
Figure 17. Introducing an element
++FUNCTION(FUN0001) /* SYSMOD type and identifier. */.
++VER(Z038) /* For MVS SREL */.
++MOD(MOD1) RELFILE(1) /* Introduce this module */
DISTLIB(AOSFB) /* in this distribution library. */.
++MOD(MOD2) RELFILE(1) /* Introduce this module */
DISTLIB(AOSFB) /* in this distribution library. */.
++MOD(MOD3) RELFILE(1) /* Introduce this module */
DISTLIB(AOSFB) /* in this distribution library. */.
++MOD(MOD4) RELFILE(1) /* Introduce this module */
DISTLIB(AOSFB) /* in this distribution library. */.
Figure 18. Example of a simple function SYSMOD
52 z/OS Basic Skills Information Center: z/OS system installation and management
is intended to prevent, it is wise to install the PTF on your system. The PTF
SYSMOD is used to install the PTF, thereby preventing the occurrence of that
problem on your system.
Usually, PTFs are designed to replace or update one or more complete elements of
a system function. Look at Figure 19, which shows a previously installed load
module, LMOD2. To replace the element MOD1, you would install a PTF SYSMOD
that contains the module MOD1. That PTF SYSMOD replaces the element in error
with the corrected element.
As part of the installation of the PTF SYSMOD, SMP/E relinks LMOD2 to include
the new and corrected version of MOD1.
Figure 20 shows an example of a simple PTF SYSMOD.
PTF SYSMODs are always dependent upon the installation of a function SYSMOD.
In some cases, some PTF SYSMODs may also be dependent upon the installation
of other PTF SYSMODs. These dependencies are called prerequisites.
PTF, APAR, and USERMOD SYSMODs all have the function SYSMOD as a
prerequisite. In addition to their dependencies on the function SYSMOD:
v PTF SYSMODs might be dependent upon other PTF SYSMODs.
v APAR SYSMODs might be dependent upon PTF SYSMODs and other APAR
SYSMODs.
v USERMOD SYSMODs might be dependent upon PTF SYSMODs, APAR
SYSMODs, and other USERMOD SYSMODs.
Sometimes a PTF or even an APAR is dependent upon other PTF SYSMODs called
corequisites. Consider the complexity of these dependencies– When you multiply
that complexity by hundreds of load modules in dozens of libraries, the need for a
tool like SMP/E becomes apparent.
Figure 19. Preventing problems with an element
++PTF(PTF0001) /* SYSMOD type and identifier. */.
++VER(Z038) FMID(FUN0001) /* Apply to this product. */.
++MOD(MOD1) /* Replace this module */
DISTLIB(AOSFB) /* in this distribution library. */.
...
... object code for module
...
Figure 20. Example of a simple PTF SYSMOD
Chapter 13. System installation and maintenance using SMP/E 53
APAR SYSMOD: Fixing problems with an element
You may sometimes find it is necessary to correct a serious problem that occurs on
your system before a PTF is ready for distribution. In this situation, IBM supplies
you with an authorized program analysis report (APAR). An APAR is a fix
designed to quickly correct a specific area of an element or replace an element in
error. You install an APAR SYSMOD to implement a fix, thereby updating the
incorrect element.
In Figure 21, the shaded section shows an area of MOD2 containing an error.
The processing of the APAR SYSMOD provides a modification for object module
MOD2. During the installation of the APAR SYSMOD, MOD2 is updated (and
corrected) in load module LMOD2.
Figure 22 shows an example of a simple APAR SYSMOD.
The APAR SYSMOD always has the installation of a function SYSMOD as a
prerequisite, and can also be dependent upon the installation of other PTF or
APAR SYSMODs.
PTF, APAR, and USERMOD SYSMODs all have the function SYSMOD as a
prerequisite. In addition to their dependencies on the function SYSMOD:
v PTF SYSMODs might be dependent upon other PTF SYSMODs.
v APAR SYSMODs might be dependent upon PTF SYSMODs and other APAR
SYSMODs.
v USERMOD SYSMODs might be dependent upon PTF SYSMODs, APAR
SYSMODs, and other USERMOD SYSMODs.
Sometimes a PTF or even an APAR is dependent upon other PTF SYSMODs called
corequisites. Consider the complexity of these dependencies– When you multiply
that complexity by hundreds of load modules in dozens of libraries, the need for a
tool like SMP/E becomes apparent.
Figure 21. Fixing problems with an element
++APAR(APAR001) /* SYSMOD type and identifier. */.
++VER(Z038) FMID(FUN0001) /* Apply to this product */
PRE(UZ00004) /* at this service level. */.
++ZAP(MOD2) /* Update this module */
DISTLIB(AOSFB) /* in this distribution library. */.
...
... zap control statements
...
Figure 22. Example of a simple APAR SYSMOD
54 z/OS Basic Skills Information Center: z/OS system installation and management
USERMOD SYSMOD: Customizing an element
If you had a requirement for a product to perform differently from the way it was
designed, you might want to customize that element of your system. IBM provides
you with certain modules that allow you to tailor IBM code to meet your specific
needs. After making the desired changes, you add these modules to your system
by installing a USERMOD SYSMOD.
This SYSMOD can be used to replace or update an element, or to introduce a
totally new user-written element into the system. In either case, the USERMOD
SYSMOD is built by you either to change IBM code or to add your own code to
the system.
In Figure 23, MOD3 has been updated through the installation of a USERMOD
SYSMOD.
Figure 24 shows an example of a simple USERMOD SYSMOD.
PTF, APAR, and USERMOD SYSMODs all have the function SYSMOD as a
prerequisite. In addition to their dependencies on the function SYSMOD:
v PTF SYSMODs might be dependent upon other PTF SYSMODs.
v APAR SYSMODs might be dependent upon PTF SYSMODs and other APAR
SYSMODs.
v USERMOD SYSMODs might be dependent upon PTF SYSMODs, APAR
SYSMODs, and other USERMOD SYSMODs.
Sometimes a PTF or even an APAR is dependent upon other PTF SYSMODs called
corequisites. Consider the complexity of these dependencies– When you multiply
that complexity by hundreds of load modules in dozens of libraries, the need for a
tool like SMP/E becomes apparent.
Figure 23. Customizing an element
++USERMOD(USRMOD1) /* SYSMOD type and identifier. */.
++VER(Z038) FMID(FUN0001) /* Apply to this product */
PRE(UZ00004) /* at this service level. */.
++SRCUPD(JESMOD3) /* Update this source module */
DISTLIB(AOSFB) /* in this distribution library. */.
...
... update control statements
...
Figure 24. Example of a simple USERMOD SYSMOD
Chapter 13. System installation and maintenance using SMP/E 55
Best practice: Keep track of system elements and
modifications
The importance of keeping track of system elements and their modifications
becomes readily apparent when we examine the z/OS maintenance process.
Often, a PTF contains multiple element replacements. In the example shown in
Figure 25, PTF1 contains replacements for two modules, MOD1 and MOD2.
Although load module LMOD2 contains four modules, only two of those modules
are being replaced.
But what happens if a second PTF replaces some of the code in a module that was
replaced by PTF1, as shown in Figure 26?
In this example, PTF2 contains replacements for MOD2 and MOD3. For MOD1,
MOD2, and MOD3 to interface successfully, PTF1 must be installed before PTF2.
That’s because MOD3 supplied in PTF2 may depend on the PTF1 version of
MOD1 to be present. It is this dependency that constitutes a prerequisite. SYSMOD
prerequisites are identified in the modification control statements (MCS) part of the
SYSMOD package.
In addition to tracking prerequisites, there is another important reason to track
system elements. The same module is often part of many different load modules,
as shown in Figure 27 on page 57.
Figure 25. PTF replacement
Figure 26. PTF prerequisite
56 z/OS Basic Skills Information Center: z/OS system installation and management
In Figure 27, the same MOD2 module is present in LMOD1, LMOD2, and LMOD3.
When a PTF is introduced that replaces the element MOD2, that module must be
replaced in all the load modules in which it exists. Therefore, it is imperative that
we keep track of all load modules and the modules they contain.
Tracking and controlling requisites
To track and control elements successfully, all elements and their modifications and
updates must be clearly identified to SMP/E. SMP/E relies on modification
identifiers to accomplish this. There are three modification identifiers associated
with each element:
v Function Modification Identifiers (FMIDs) identify the function SYSMOD that
introduces the element into the system.
v Replacement Modification Identifiers (RMIDs) identify the last SYSMOD (in
most cases a PTF SYSMOD) to replace an element.
v Update Modification Identifiers (UMIDs) identify the SYSMOD that an update to
an element since it was last replaced.
SMP/E uses these modification identifiers to track all SYSMODs installed on your
system. This ensures that they are installed in the proper sequence.
The SMP/E process for installing z/OS elements or service
This summary of SMP/E processing illustrates how z/OS elements or service
updates are installed.
SMP/E provides an excellent inventory and cross-reference of software
dependencies, and a mechanism for installing new products or applying software
maintenance. These capabilities ensure integrity of the overall system. The
mechanics of using SMP/E to maintain a system can be quite simple, as shown in
Figure 28 on page 58. How SMP/E works and the knowledge needed to package
fixes and software producets for SMP/E is significantly complex. IBM provides
instructions for system programmers to follow with all SMP/E packaged fixes,
Systemlibraries
ZO
SB
046a-0
LMOD1
MOD1
MOD2
MOD3
MOD4
LMOD2
MOD1
MOD2
MOD3
MOD4
LMOD3
MOD1
MOD2
MOD3
MOD4
MOD2
Figure 27. Load module constructions
Chapter 13. System installation and maintenance using SMP/E 57
software upgrades, and products.
Figure 29 provides a sample of the job control language (JCL) that might be used
to automate the process from receiving updates to applying them to a target
system.
SMP/E commands
Three commands– RECEIVE, APPLY, and ACCEPT– drive the SMP/E process for
installing z/OS elements or service.
Additional SMP/E commands include:
v LIST command: When you need an all-inclusive hardcopy listing of information
about your system
v REPORT commands: To check and compare the zone contents and generate
command output that can be used to update your system
CSI
ZO
SB
05
4-0
Glob
CSICSI
Targ
TLIBs DLIBs
Distribut
SMPPTS SMPTLIBsServicetape
RECEIVEcommand
APPLYcommand
ACCEPTcommand
RESTOREcommand
Website
Figure 28. Overall SMP/E process flow
//SMPJOB JOB ’accounting info’,MSGLEVEL=(1,1)
//SMPSTEP EXEC SMPPROC
//SMPPTFIN DD ...
/* points to file or data set containing SYSMODs to be received */
//SMPHOLD DD ...
/* points to file or data set containing HOLDDATA to be received */
//SMPTLIB DD UNIT=3380,VOL=SER=TLIB01
//SMPCNTL DD *
SET BDY(GLOBAL) /* Set to global zone */.
RECEIVE SYSMOD /* Receive SYSMODs */
HOLDDATA /* Receive HOLDDATA */
SOURCEID(MYPTFS) /* Assign a source ID */
/* */.
LIST MCS /* List the cover letters */
SOURCEID(MYPTFS) /* for the SYSMODs */
/* */.
SET BDY(TARGET1) /* Set to target zone */.
APPLY SOURCEID(MYPTFS) /* Apply the SYSMODs */
/* */.
LIST LOG /* List the target zone log */.
/*
Figure 29. SMP/E batch job example
58 z/OS Basic Skills Information Center: z/OS system installation and management
The SMP/E RECEIVE command
The RECEIVE command allows you to take a SYSMOD that is outside of SMP/E
and stage it into the SMP/E library domain, which begins to construct the CSI
entries that describe them. This staging allows them to be queried for input into
later processes. More recently, the source can be electronic from a Web site,
although usually it comes from a tape or even a third-party vendor media.
The RECEIVE process accomplishes several tasks that are shown in Figure 30.
These tasks include:
v Constructing entries in the Global Zone for describing the SYSMOD.
v Ensuring the SYSMOD is valid, such as the syntax for modification control
statements (MCS) associated to the products installed in the CSI.
v Installing the SYSMOD into the libraries. Example: the PTF temporary store
library.
v Assessing the HOLDDATA to ensure errors are not introduced.
During the RECEIVE processing, the MCS for each SYSMOD is copied to an
SMP/E temporary storage area called the SMPPTS data set, which contains the
inline element replacement or update for that SYSMOD. There are also RELFILEs
that package the elements in relative files that are separate from MCSs, which are
mostly used by function SYSMODs. Relative files are stored in another temporary
storage area called SMPTLIB data sets.
SMP/E updates the global zone with information about the SYSMODs that it has
received.
In the course of maintaining the system, you need to install service and process the
related HOLDDATA. For example, assume that IBM has supplied you with a
service tape (such as a CBPDO or ESO tape) and you want to install it on the
system. The first step is to receive the SYSMODs and HOLDDATA that are
contained on the tape by entering these commands:
SET BDY(GLOBAL).
RECEIVE.
CSI
ZO
SB
05
1-0
Glob
CSICSI
Targ
TLIBs DLIBs
Distribut
SMPPTS SMPTLIBsServicetape
RECEIVEcommand
APPLYcommand
ACCEPTcommand
RESTOREcommand
Website
Glob Targ Distribut
Figure 30. SMP/E RECEIVE processing
Chapter 13. System installation and maintenance using SMP/E 59
Doing so causes SMP/E to receive all the SYSMODs and HOLDDATA on the tape.
Examples of RECEIVE commands
To receive only HOLDDATA that might require special handling or that is in error,
you use this command:
SET BDY(GLOBAL).
RECEIVE HOLDDATA.
To receive only SYSMODs for installation into the global zone, you use this
command:
SET BDY(GLOBAL).
RECEIVE SYSMODS.
To receive all SYSMODs, including HOLDDATA, for a specific product (for
example, WebSphere Application Server), you use a command like the following:
SET BDY(GLOBAL).
RECEIVE FORFMID(H28W500).
The SMP/E APPLY command
The APPLY command specifies which of the received SYSMODs are to be selected
for installation in the target libraries. SMP/E also ensures that all other required
SYSMODs (prerequisites) have been installed or are being installed concurrently as
well as in the proper sequence.
The source of the elements is the SMPTLIB data sets, the SMPPTS data set or
indirect libraries depending on how is was packaged. This phase of the SMP/E
process entails the following:
v Executing the appropriate utility to install the SYSMOD into the target library,
depending on the type of input text supplied and target module being changed.
v Ensuring that the relationship of the new SYSMOD with other SYSMODs in the
target zone is correct.
v The CSI is modified displaying the updated modules.
The APPLY command updates the system libraries and should be carefully used on
a live production system. It is recommended that you initially use a copy of the
production target libraries and zones.
The target zone reflects the content of the target libraries. Therefore, after the
utility is completed and the zone updated, it will accurately reflect the status of
those libraries.
60 z/OS Basic Skills Information Center: z/OS system installation and management
The APPLY processing, shown in Figure 31, is where the target zone is accurately
updated:
v All SYSMOD entries in the Global Zone are updated to reflect that the SYSMOD
has been applied to the target zone.
v The target zone accurately reflects each SYSMOD entry applied. Element entries
(such as MOD and LMOD) are also created in the target zone.
v BACKUP entries are created in the SMPSCDS data set so the SYSMOD can be
restored, if at all necessary.
Similar to the RECEIVE process, the APPLY command has many different
operands for flexibility to select SYSMODs you would like to see for installation in
the target libraries, and provides an assortment of output. The directives used
instruct SMP/E what you want installed.
Examples of APPLY commands
To install only PTF SYSMODs, enter a command like the following:
SET BDY(ZOSTGT1).
APPLY PTFS.
To select PTF SYSMODs, you name them in the directives, for example:
SET BDY(ZOSTGT1).
APPLY SELECT(UZ00001, UZ00002).
Sometimes, you might want to install only corrective fixes (APARs) or user
modifications (USERMODs) into the target library, for example:
SET BDY(ZOSTGT1).
APPLY APARS
USERMODS.
At other times, you might want to update a selected product from a distribution
tape:
SET BDY(ZOSTGT1).
APPLY PTFS
FORFMID(H28W500).
Or:
CSI
ZO
SB
05
2-0
Glob
CSICSI
Targ
TLIBs DLIBs
Distribut
SMPPTS SMPTLIBsServicetape
RECEIVEcommand
APPLYcommand
ACCEPTcommand
RESTOREcommand
Website
Targ Distribut
Figure 31. SMP/E APPLY processing
Chapter 13. System installation and maintenance using SMP/E 61
SET BDY (ZOSTGT1).
APPLY FORFMID(H28W500).
In these two examples, SMP/E applies all applicable PTFs for the FMID. Unless
you specify otherwise, PTFs are the default SYSMOD type.
The APPLY command with the CHECK operand
There might be times when you want to see which SYSMODs are included before
you actually install them. You can do this by including the CHECK operand with
commands such as the following:
SET BDY(MVSTGT1).
APPLY PTFS
APARS
FORFMID(HOP1)
GROUPEXTEND
CHECK.
When these commands complete, you can check the SYSMOD status report to see
which SYSMODs would have been installed if you had not specified the CHECK
operand. If you are satisfied with the results of this trial run, you can enter the
commands again, without the CHECK operand, to actually install the SYSMODs.
The SMP/E ACCEPT command
When a SYSMOD is installed into its target library, and you have tested it, you
then accept the change through the ACCEPT command. This step takes the
selected SYSMODs and installs them into the associated distribution libraries.
On the ACCEPT command, you specify operands to indicate which of the received
SYSMODs are to be selected for installation. During this phase, SMP/E also
ensures that the correct functional level of each element is selected.
The ACCEPT command performs the following tasks, shown in Figure 32:
v Updates CSI entries with the targeted elements in the distribution zone.
v Rebuilds or creates the targeted elements in the distribution libraries using the
content of the SYSMOD as input.
CSI
ZO
SB
05
3-0
Glob
CSICSI
Targ
TLIBs DLIBs
Distribut
SMPPTS SMPTLIBsServicetape
RECEIVEcommand
APPLYcommand
ACCEPTcommand
RESTOREcommand
Website
or
Figure 32. SMP/E ACCEPT processing
62 z/OS Basic Skills Information Center: z/OS system installation and management
v Verifies the target zone CSI entries for the affected modules and SYSMODs,
ensuring that they are consistent with the library content.
v Performs housekeeping of obsolete or expired elements. ACCEPT processing
deletes the global zone CSI entries, PTS members and SMPTLIBs for those
SYSMODs affected. For example, ACCEPT deletes the global zone SYSMOD
entries and MCS statements in the SMPPTS data set for those SYSMODs that
have been accepted into the distribution zone.
As a further option, you can skip having SMP/E clean up the global zone cleanup.
If so, SMP/E saves this information.
There is a ″stop″ ACCEPT processing that SMP/E provides so you can ensure that
all prerequisites are satisfied before the installation of the SYSMODs. This is a
check for you to see what will happen (assist you in detecting problems) without
actually modifying the distribution libraries.
After applying the SYSMODs into the Target zone, you can then tell SMP/E to
install only the eligible PTF SYSMODs into the Distribution zone:
SET BDY(ZOSDLB1).
ACCEPT PTFS.
Examples of ACCEPT commands
To install PTF SYSMODS selecting the particular ones:
SET BDY(ZOSDLB1).
ACCEPT SELECT(UZ00001,UZ00002).
There are situations where you may want to update a particular product with all
SYSMODs:
SET BDY(ZOSDLB1).
ACCEPT PTFS
FORFMID(H28W500).
Or:
SET BDY(ZOSDLB1).
ACCEPT FORFMID(H28W500).
In these two examples, SMP/E accepts all applicable PTFs for the product whose
FMID is H28W500 located in the Distribution zone ZOSDLB1.
Note: Should the SYSMOD be in error, do not accept it. Use the RESTORE process
which takes the updated modules and rebuilds the copies in the Target libraries
from the specific modules in the Distribution libraries. Additionally, RESTORE
updates the Target zone CSI entries to reflect the removal of the SYSMOD.
Note: When ACCEPT processing is complete, it cannot be backed out. ACCEPT
should only be performed after you are satisfied with the performance and
stability of the elements of the SYSMOD. The changes from ACCEPT processing
are permanent.
The ACCEPT processing for prerequisite SYSMODs
When installing a SYSMOD, you may not know whether it has prerequisites
(sometimes, an ERROR SYSMOD is held). In these situations, you can direct
SMP/E to check whether an equivalent (or superseding) SYSMOD is available by
specifying the GROUPEXTEND operand:
Chapter 13. System installation and maintenance using SMP/E 63
SET BDY(ZOSDLB1).
ACCEPT PTFS
FORFMID(H28W500)
GROUPEXTEND.
A good way to see which SYSMODs are included before you actually install them
is with the CHECK operand:
SET BDY(ZOSTGT1).
ACCEPT PTFS
FORMFMID(H28W500)
GROUPEXTEND
CHECK.
Note: If SMP/E cannot find a required SYSMOD, it looks for and uses a SYSMOD
that supersedes the required one.
ACCEPT reporting
When this last phase is completed, the following reports will assist you to assess
the results:
v SYSMOD Status Report: Provides a summary of the processing that took place
for each SYSMOD, based on the operands you specified on the ACCEPT
command.
v Element Summary Report: Provides a detailed look at each element affected by
the ACCEPT processing and in which libraries they reside.
v Causer SYSMOD Summary Report: Provides a list of SYSMODs that caused
other SYSMODs to fail and describes the errors that must be fixed in order to be
successfully processed.
v File Allocation Report: Provides a list of the data sets used for the ACCEPT
processing and supplies information about these data sets.
64 z/OS Basic Skills Information Center: z/OS system installation and management
Part 6. Appendixes
© Copyright IBM Corp. 2005, 2008 65
66 z/OS Basic Skills Information Center: z/OS system installation and management
Notices
This information was developed for products and services offered in the U.S.A.
IBM may not offer the products, services, or features discussed in this document in
other countries. Consult your local IBM representative for information on the
products and services currently available in your area. Any reference to an IBM
product, program, or service is not intended to state or imply that only that IBM
product, program, or service may be used. Any functionally equivalent product,
program, or service that does not infringe any IBM intellectual property right may
be used instead. However, it is the user’s responsibility to evaluate and verify the
operation of any non-IBM product, program, or service.
IBM may have patents or pending patent applications covering subject matter
described in this document. The furnishing of this document does not grant you
any license to these patents. You can send license inquiries, in writing, to:
IBM Director of Licensing
IBM Corporation
North Castle Drive
Armonk, NY 10504-1785
U.S.A.
For license inquiries regarding double-byte (DBCS) information, contact the IBM
Intellectual Property Department in your country or send inquiries, in writing, to:
IBM World Trade Asia Corporation
Licensing
2-31 Roppongi 3-chome, Minato-ku
Tokyo 106-0032, Japan
The following paragraph does not apply to the United Kingdom or any other
country where such provisions are inconsistent with local law:
INTERNATIONAL BUSINESS MACHINES CORPORATION PROVIDES THIS
PUBLICATION ″AS IS″ WITHOUT WARRANTY OF ANY KIND, EITHER
EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, THE IMPLIED
WARRANTIES OF NON-INFRINGEMENT, MERCHANTABILITY OR FITNESS
FOR A PARTICULAR PURPOSE. Some states do not allow disclaimer of express or
implied warranties in certain transactions, therefore, this statement may not apply
to you.
This information could include technical inaccuracies or typographical errors.
Changes are periodically made to the information herein; these changes will be
incorporated in new editions of the publication. IBM may make improvements
and/or changes in the product(s) and/or the program(s) described in this
publication at any time without notice.
Any references in this information to non-IBM Web sites are provided for
convenience only and do not in any manner serve as an endorsement of those Web
sites. The materials at those Web sites are not part of the materials for this IBM
product and use of those Web sites is at your own risk.
© Copyright IBM Corp. 2005, 2008 67
IBM may use or distribute any of the information you supply in any way it
believes appropriate without incurring any obligation to you.
Licensees of this program who wish to have information about it for the purpose
of enabling: (i) the exchange of information between independently created
programs and other programs (including this one) and (ii) the mutual use of the
information which has been exchanged, should contact:
IBM Corporation
Mail Station P300
2455 South Road
Poughkeepsie, NY 12601-5400
U.S.A.
Such information may be available, subject to appropriate terms and conditions,
including in some cases, payment of a fee.
The licensed program described in this document and all licensed material
available for it are provided by IBM under terms of the IBM Customer Agreement,
IBM International Program License Agreement or any equivalent agreement
between us.
Information concerning non-IBM products was obtained from the suppliers of
those products, their published announcements or other publicly available sources.
IBM has not tested those products and cannot confirm the accuracy of
performance, compatibility or any other claims related to non-IBM products.
Questions on the capabilities of non-IBM products should be addressed to the
suppliers of those products.
This information contains examples of data and reports used in daily business
operations. To illustrate them as completely as possible, the examples include the
names of individuals, companies, brands, and products. All of these names are
fictitious and any similarity to the names and addresses used by an actual business
enterprise is entirely coincidental.
COPYRIGHT LICENSE:
This information contains sample application programs in source language, which
illustrate programming techniques on various operating platforms. You may copy,
modify, and distribute these sample programs in any form without payment to
IBM, for the purposes of developing, using, marketing or distributing application
programs conforming to the application programming interface for the operating
platform for which the sample programs are written. These examples have not
been thoroughly tested under all conditions. IBM, therefore, cannot guarantee or
imply reliability, serviceability, or function of these programs.
If you are viewing this information softcopy, the photographs and color
illustrations may not appear.
Programming interface information
This book documents information that is NOT intended to be used as
Programming Interfaces of z/OS.
68 z/OS Basic Skills Information Center: z/OS system installation and management
Trademarks
IBM, the IBM logo, and ibm.com are trademarks or registered trademarks of
International Business Machines Corporation in the United States, other countries,
or both. If these and other IBM trademarked terms are marked on their first
occurrence in this information with a trademark symbol (® or
™), these symbols
indicate U.S. registered or common law trademarks owned by IBM at the time this
information was published. Such trademarks may also be registered or common
law trademarks in other countries. A current list of IBM trademarks is available on
the Web at ″Copyright and trademark information″ at http://www.ibm.com/legal/copytrade.shtml
UNIX is a registered trademark of The Open Group in the United States and other
countries.
Other company, product, or service names may be trademarks or service marks of
others.
Notices 69
70 z/OS Basic Skills Information Center: z/OS system installation and management
����
Printed in USA