zw electric pump series
TRANSCRIPT
ZW Electric Pump Series
Hydr
aulic
Tech
nolog
y Wor
ldwi
de
Unsurpassed in technology, design and features — only
from the market leader in industrial hydraulic pumps.
Motor lip seal
Replaceable pistoncheck valves
Self-priming, high-flow 1st stage pump
Balanced eccentricHeavy-duty bearings
Oil bath
Introducing the Z-Class power pumps from Enerpac—pumps that run cooler, use less electricity and are easy to service.
Enerpac has used the latest metallurgical,
bearing and seal technologies to produce a
pump whose features and benefits far
surpass the electric pumps that are available
today. By reducing the number of moving
parts, improving flow dynamics and
decreasing friction, Z-Class pumps will stay
on the job longer, require less energy to
operate and when needed, have lower
service costs.
Z-Class electric pumps fromEnerpac—simply the bestpump you will ever use.
ZE Series Electric Pumps
Available in 4 flow ranges and singleand two-stage models, to provide theoptimum cylinder and tool performancefor almost any industrial application.
Pump Motor Flow @ RatedSeries Size PressureZW4 1.0 hp 60 in3/minZW5 1.5 hp 120 in3/min
Extensive list of accessories includingheat exchanger, roll-bars, pressuretransducer and level and temperatureswitches, allow complete pump control over a wide range of industrial applications.
Low-voltage pendant features sealedswitches and operates at 15 vdc forimproved operator safety.
Totally enclosed, fan-cooledindustrial motor provides safe,trouble-free operation for the life of thepump.
Optional back-lit LCD- pump usage information, hour and
cycle counts- low-voltage warning and recording- self-test and diagnostic capabilities- information displayed in 6 languages- pressure read-out (when used with
optional pressure transducer)- Auto-mode pressure setting
(when used with optional pressure transducer)
An Innovation in Pump DesignZ-Class Pumping Element
Highly efficient design providesincreased flow rates, reduced heatgeneration and a decrease in powerconsumption. This means improved tool speed and increased service life—which results in higher productivity andlower operating costs.
Heavy-duty bearings extend pump lifeby reducing friction, reducing surface-loading and lowering bearing stresses.
Pump cavity oil bath extends pumplife by reducing heat, improvinglubrication and reducing wear.
Self-priming, high-flow 1st stagepump increases pump performance by super-charging the 2nd stage pistonpump—improving oil flow in both hotand cold weather operation.
Balanced rotating componentsreduce vibration creating a smootherrunning pump—reducing wear, frictionand sound levels.
Replaceable piston check-valvesincrease service life of major pump components.
Electric Pumps Application & selection
Z-Class electric pumps are designed for use in theharshest manufacturing environments. The pumpsprovide reliable and durable performance in a widevariety of configurations.
The new standard for workholdingapplications
• Features Z-Class high-efficiency pump design; higher oilflow and by-pass pressure, cooler running and requires18% less current than comparable pumps
• Totally enclosed, fan cooled industrial electric motorssupply extended life and stand up to harsh industrialenvironments
• Multiple valve and reservoir configurations provideapplication specific models to match the mostdemanding workholding applications
• High-strength, molded electrical enclosure protectselectronics, power supplies and LCD readout fromcoolant and contamination
4 www.enerpac.com© 2005
ZW-Series with manual valve
• Provides manual control of one single or double-actingcircuit
• Control valve supplied with center holding function toensure positive pressure holding
ZW-Series with solenoid valve
• Provides solenoid control of one single or double-actingcircuit
• Control valve supplied with integrated pilot operatedcheck to ensure positive pressure holding
ZW-Series with dump valve
• Provides momentary pressure and flow to fixture
• Ideal for pallet disconnect systems
ZW-Series with manifold
• Used when supplying pressure to multiple valve circuits
• Valves must be supplied separately
Basic configurationsAll pumps listed in this chart include LCD electrical box, 5 gallon reservoir, return line filter and 0-6000 psi pressuregauge. For additional options, see the complete pumpmatrix on page 11.
Pump type Valve/manifold type Motor voltage50/60 Hz
Pressure and tank portsPressure and tank portsEnerpac VP-seriesEnerpac VP-series2-station D034-station D03
Single-acting dumpSingle-acting dumpSingle-acting dump
3 way, 3 position tandem center3 way, 3 position tandem center3 way, 3 position tandem center4 way, 3 position tandem center4 way, 3 position tandem center4 way, 3 position tandem center
3 way, 3 position tandem center3 way, 3 position tandem center3 way, 3 position tandem center4 way, 3 position tandem center4 way, 3 position tandem center4 way, 3 position tandem center
115 VAC, 1 ph230 VAC, 3 ph115 VAC, 1 ph230 VAC, 3 ph230 VAC, 3 ph230 VAC, 3 ph
115 VAC, 1 ph230 VAC, 3 ph460 VAC, 3 ph
115 VAC, 1 ph230 VAC, 3 ph460 VAC, 3 ph115 VAC, 1 ph230 VAC, 3 ph460 VAC, 3 ph
115 VAC, 1 ph230 VAC, 3 ph460 VAC, 3 ph115 VAC, 1 ph230 VAC, 3 ph460 VAC, 3 ph
ZW series
Flow rate: 60-120 in3/min
Pressure: 5000 psi max
Motor: 1.0 & 1.5 HP
Reservoir: 2.5-10 gallon
LCD electrical package isrequired for pumps utilizingelectric valves, or optionalaccessories such as the
pressure transducer, levelswitch, pressure switch or
heat exchanger.
Important
5© 2005www.enerpac.com
ZW4 Series Output oil flow at 5000 psi
60 in3/min
ZW4020HB-FG01ZW4020HG-FG01ZW4020HB-FG12ZW4020HG-FG12ZW4020HG-FG21ZW4020HG-FG41
ZW4120DB-FGZW4120DG-FGZW4120DJ-FG
ZW4320LB-FGZW4320LG-FGZW4320LJ-FGZW4420LB-FGZW4420LG-FGZW4420LJ-FG
ZW4320SB-FGZW4320SG-FGZW4320SJ-FGZW4420SB-FGZW4420SG-FGZW4420SJ-FG
LCD Electric Model Number
ZW5020HB-FG01ZW5020HG-FG01ZW5020HB-FG12ZW5020HG-FG12ZW5020HG-FG21ZW5020HG-FG41
ZW5120DB-FGZW5120DG-FGZW5120DJ-FG
ZW5320LB-FGZW5320LG-FGZW5320LJ-FGZW5420LB-FGZW5420LG-FGZW5420LJ-FG
ZW5320SB-FGZW5320SG-FGZW5320SJ-FGZW5420SB-FGZW5420SG-FGZW5420SJ-FG
Single-stage pumps provide constant flow throughout the entirepressure range via a radial piston pump. Two-stage pumps provide highflow via a gear pump until the bypass pressure is reached. At pressuresabove the bypass setting, the radial piston pump provides flow to themaximum pressure.
0
Pressure (psi) ➔
ZW4 Oil flow & current vs hydraulic pressure
Oil f
low
(in3 /
min
) ➔
500040003000200010000
1000
800
600
400
200
Single StageTwo StageCurrent draw @ 115 VAC
Curr
ent d
raw
(A) ➔
0
25
20
15
10
5
0
Pressure (psi) ➔
ZW5 Oil flow & current vs hydraulic pressure
Oil f
low
(in3 /
min
) ➔
500040003000200010000
1000
800
600
400
200
Single StageTwo StageCurrent draw @ 115 VAC
Curr
ent d
raw
(A) ➔
0
25
20
15
10
5
ZW5 Series Output oil flow at 5000 psi
120 in3/min
LCD Electric Model Number
Important
Output oil flow and current draw
All Z-Class electric pumpsare CSA and CE compliant.
Electric pumps Dimensions & options
Z-Class electric pumps aresupplied with factory installedaccessories such as valvemanifold, pressure transducer,and return line filter, creating acomplete power unit solution.
• Efficient design reduces heat generation andreduces power consumption
• Balanced pump section reduces vibrationimproving durability and sound levels
• Optional back-lit LCD readout provides hourand cycle counts, low voltage warnings andpressure read-out when used with pressuretransducer
• Low-voltage pendant on solenoid valvemodels with sealed switches improvesoperator safety
6 www.enerpac.com© 2005
Flow rate: 60-120 in3/min
Pressure: 5000 psi max
Motor: 1.0 & 1.5 HP
Reservoir: 2.5-10 gallon
Product dimensions in inches [ ]Usable oil Pump Pump dimensions (in)capacity series
lbs
gal A B C D E ZW4 ZW5
* Weight shown is for basic pump unit without accessories**See pages 4-5 and 11 for more information about specifying a complete Z-Class power unit model number
2.5 ZWxx10xx 6.1 14.6 12.0 15.1 11.0 107 1155.0 ZWxx20xx 7.1 19.2 16.6 19.7 15.6 134 142
10.0 ZWxx40xx 10.6 22.5 19.9 22.7 18.9 184 193
Output flow rate Pump Motor Relief valve Soundin3/min series size adjustment range level
max.100 psi 700 psi 3000 psi 5000 psi hp psi dBA
Product selection
350 305 63 60 ZW4 1.0 1,000–5,000 75650 602 123 120 ZW5 1.5 1,000-5,000 75
E2.5
2.1
1.912.0
Oil Fill Port
4x Ø .34Mounting Hole
Breather
AUX Tank PortSAE #8
18.1
User AdjustableRelief Valve
VE43 Valve Shown
Electrical box-optional with manual valve
Optional roll cage
Oil Drain/Oil Level/
Temp SwitchPort
16.5
24.027.9
17.514.9Max
A
D
B A
COil LevelSight gauge
Reservoir Handles (Standard)
B
Heat exchanger (optional)
Shown: ZW5020HB-FT01
7© 2005www.enerpac.com
Manifolds allow the use ofmultiple valves powered by asingle hydraulic pump.Manifolds are available factoryinstalled on your Z-Classworkholding power unit, orseparately for future systemupgrades.
Increased flexibility for complexsystems
• Manifolds provide hydraulic connection toremote or pump mounted valves
• Used when multiple valves are required forcontrolling several independent circuits
• Available for 2 and 4 station D03 as well asEnerpac VP series mounting
• Pressure and tank porting manifoldavailable for use with remote valve sticks
• Manifolds include integrated relief valvefor system pressure control
❚ Enerpac porting manifoldprovides pressure and tank line to remote mounted valve stack on a machining center.
Pressure: 5000 psi
Stations: 1-4 horizontal
Stations: 1-8 vertical
1.00 2.00 2.00 2.00
3.62
VMMD-001 SHOWN FOR REFERENCE ONLY
#8 SAE (8x)0.750-16 UN
1.70
3.84
P T
#8 SAE (2x)0.750-16 UN
3/8" tube (2x)(37 deg flare)
1.38
Adjustablerelief valve
Product selection
Valve mounting pattern Option code Number of Coverplate(see page 11) stations model number
Porting manifold, SAE ports 01 – –Enerpac VP Series 12 1-8 –2 station D03 21 2 MC-14 station D03 41 4 MC-1
3.52
2.001.00
#8 SAE (8x)0.750-16 UN
2.002.00
VMMD-001 Shown forreference only
VP11 Shown for reference only
1.38
1.70
3.84Adjustablerelief valve
3/8" tube (2x)(37 deg. flare)
Option 01
Option 12
Option 21,41 Option 21 has two valve stationsOption 41 has four valve stations
Valve manifolds ZW series
Options
Pressure transducer
9 �
Level switch
9 �
0.250-18 NPTFgauge port
0.375-18 NPTFtank port
4.06
© 200588 www.enerpac.com
ZPF-series
The oil filter kit removescontaminants from the return oil flow before allowing it backinto the reservoir, reducingcomponent damage.
Extend life of hydrauliccomponents
…increase system reliability
• 25 micron nominal filter cleans oil to increase system life
• Internal bypass valve to prevent damage if the filter is dirty
• All installation components included
• Kit assembles quickly and easily to Enerpac pump and manifold
• Maintenance indicator included
Product selectionNominal Model Maximum Maximum Bypass Filterfiltration number pressure oil flow pressure gauge/
setting serviceindicator
micron psi gpm psi lbs
Shown: ZHE-E10
ZHE-series
Heat exchanger removes heat from the return oil to provide cooler operation.
Product selection
*At 0.5 G/min and ambient temperature of 70°F.
Voltage Model Thermal Amperage Maximum Maximumnumber transfer * draw pressure oil flow
Btu/h kJoule A psi gpm lbs
Shown: ZPF
PF25Replacementfilter element
For best performance,replace filter element on a
regular basis. Change filterswhen changing oil or 4times a year, whichever
comes first.
Transfer: 900 Btu/h
Pressure: max. 300 psi
Voltage: 24V
Pressure: max. 200 psi
Filtration: 25 micron
Max. flow: 12.0 GPM
Return line filter & heat exchanger kits ZPF, ZHE series
Options
0
Oil flow (gal/min) ➔
Pressure drop vs oil flow
Pres
sure
dro
p (p
si) ➔
1086420
100
80
60
40
20
25 ZPF 200 12.0 25 ✔ 3.2
24 VDC ZHE-E10 900 950 .95 300 7.0 9.0
0
Oil flow (in3/min) ➔
Pressure drop vs oil flow
Aver
age
pres
sure
dro
p (p
si) ➔
25002000150010005000
25
20
15
10
5
Extends system life• Electrical connector factory installed
• All installation components included
• Stabilizes oil temperature at amaximum of 130 ºF at 70 ºF ambienttemperature
• Stabilizes oil viscosity, increasing oillife and reduces wear of pump andother hydraulic components
© 2005 99www.enerpac.com
Level/temp switch & pressure transducer ZLS, ZPT series
ZLS-series
Oil level indicator for pumpreservoir. If the pump is mountedin a remote area that does notprovide visual access to theexternal oil level sight glass, thelevel/temp switch will turn off thepump before internal damagecan occur due to cavitation.
Shown: ZLS-U4
Electronic level/temp switch forfeedback on pump oil level
• Drop-in design allows for easy installation to pump reservoir
• Electrical connector included
• Built-in thermal sensing provides feedback on oil temperature
• Senses low oil level in pump reservoir
Temp. Set Point: 175 °F
Voltage: 24 VAC/DC
Product selectionFixed Model Voltage Thermostat Maximum
temperature number rating pressuresignal setting
°F Amps psi lbs
Shown: ZPT-U4, ZPS-W4
Control your pump,monitor pressure
ZPT pressure transducer
• More durable than analog gauges (againstmechanical and hydraulic shock)
• More accurate than analog gauges (0.5% fullscale)
• Calibration can be fine tuned for certification
• “Auto-mode” provides automatic pressuremake-up
• Display pressure in psi, bar or MPa
Product selection
ZPT/ZPS seriesZPT pressure transducerprovides constant pressuremonitoring for automated pumpcontrol. ZPS pressure switchshuts down motor at setpressure.
Pressure: 50-10,000 psi
Voltage: 24 VAC/DC
The pressure transducer isfactory installed in the “A”
port on pumps suppliedwith valves, and in the “P”
port on models withmanifolds.
Important
Adjustable Electrical Model Accuracy Dead-pressure specification number (full scale) band
rangepsi psi lbs
▼ Mechanical adjustment
Note: Electrical harness included with kit. ZPS-W4 includes 0-6000 psi pressure gauge.
175 ZLS-U4 24 VAC/DC 2.6 150 0.11
50-10,000 4-20 mA ZPT-U4 0.5% 50 0.3500-10,000 24 VAC/DC N.O. ZPS-W4 2% 115-550 2.7
PT
© 200510 www.enerpac.com
Z-Class power unit applications
Z-class pump model numberZW4210MB-FS is used toprovide pressure and flow to asingle machining fixture.
• Includes a 2-way manualvalve and return line filter toprotect against contamination
• Single-stage pump providesconstant 60 in3/min flow atany pressure
• The fixture has an open-center manual valve whichcontrols the clamp andunclamp function
• The pump runs continuously,building pressure when thefixture-mounted valve isactivated
Z-class pump model numberZW5020HK-FHT01 is used toprovide pressure and flow to sixmachining fixtures.
• Includes pressure transducerto monitor system pressure tosix machining centers
• The machine fixtures eachhave a manual shut off valveto control clamp and unclampfunction
• The pump runs on-demand,building pressure when thefixture-mounted valve isactivated
To fixture
Open center valve
ZW4210MB-FS
To fixture
Manual shutoffvalve
P T
PT
ZW5020HK-FGHT01
© 2005 1111www.enerpac.com
ZW Electric Pump ordering matrix ZW series
W 4 H G FG200Z 01-1
Producttype
� This is how a ZW series Model number is built:
1 Product typeZ = Z-Class Pump
2 Motor typeW = Workholding Electric
3 Flow group4 = 60 in3/min5 = 120 in3/min
4 Valve type0 = No valve or valve manifold1 = Pallet de-coupling2 = 3-way, 2-position, manual valve3 = 3-way, 3-position, tandem center4 = 4-way, 3-position, tandem center6 = 3-way, 3-position, tandem center
w/P.O. check (manual only)8 = 4-way, 3-position, tandem center
w/P.O. check (manual only)
5 Usable oil capacity10 = 10 Liters (2.5 gallon)20 = 20 Liters (5 gallon)40 = 40 Liters (10 gallon)
6 Valve operation D = Pallet de-coupling with pendant and
LCD (Valve type 1)G = Valve manifold without LCD
(Valve type 0)H = Valve manifold with LCD (Without
pendant, Valve type 0)L = Manual valve with LCD (Without
pendant)M = Manual valve without LCDN = No valve, no electrical box
(Valve type 0)S = Solenoid valve (tandem center) with
pendant and LCDW = No valve with LCD (Valve type 0)
7 VoltageSingle Phase
B = 115V, 1 ph, 50-60 Hz *3
E = 208-240V, 1 ph, 50-60 Hz European Plug
I = 208-240V, 1 ph, 50-60 Hz USA Plug
Three Phase
M = 190-200V, 3 ph, 50-60 HzG = 208-240V, 3 ph, 50-60 HzW = 380-415V, 3 ph, 50-60 HzK = 440V, 3 ph, 50-60 HzJ = 460-480V, 3 ph, 50-60 HzR = 575V, 3 ph, 60 Hz
8 Options *1
F = Return line filter, 25 micronG = 0-6000 psi pressure gauge, 2-1/2" *5
H = Heat exchanger *4
L = Level/temperature switch *4
N = No handles (lifting eyes only) *2
P = Pressure switch *4
R = Roll barsS = Single stageT = Pressure transducer *4
U = Foot switch *4
9 Manifold options (Pump types G and H only.)
01 = SAE porting manifold12 = VP series manifold21 = 2 station D0341 = 4 station D03
Custom build your pump
2Motortype
3Flowgroup
4Valvetype
5Usable
oilcapacity
6Valve
operation
7Voltage
8Options
9Manifoldoptions
ExampleThe model numberZW5810LG-FT is a 120 in3/min,
2-stage pump with a manual 4-way, 3 position tandem centervalve, integrated P.O. check,LCD electrical box, 2.5 gallonreservoir, 208-240 volt 3-phasemotor, return line filter andpressure transducer.
*1 Options should be specified in alphabeticalorder
*2 Unless specified, all pumps are supplied withreservoir handles
*3 115 volt pumps are supplied with CE & CSAapproved 15 amp plug for intermittent use. 20 A circuit recommended for frequent fullpressure use.
*4 These options require LCD electrical package.Pressure switch option only available onmanual valves without locking valve. The LCDelectrical package can accept either a pressureswitch or pressure transducer, but not both.
*5 Pressure gauge not availible on pump modelswith pressure transducer. Pressure transducerprovides digital pressure readout on LCDdisplay.
Flow rate: 60-120 in3/min
Pressure: 5000 psi max
Motor: 1.0 & 1.5 HP
Reservoir: 2.5-10 gallon
ExampleThe ZW4020GB-FGS21 is a 60 in3/min, single-stage pumpwith a 2 station D03 manifold,standard electric, 5 gallonreservoir, 115 volt, 50/60 Hzmotor, return line filter and 0-6000 psi pressure gauge.
ExampleThe ZW4110DJ-T is a 60 in3/min, 2-stage pump with apallet de-coupling valve, LCDelectrical box, 2.5 gallonreservoir, 460-480 volt 3-phase motor and pressuretransducer.
ExampleThe ZW5040HJ-FGL01 is a 120 in3/min, 2-stage pump witha SAE porting manifold, LCDelectrical box, 10 gallonreservoir, 460-480 volt 3-phase motor, return line filter,0-6000 psi pressure gauge andlevel and temperature shutdownswitch.
e-mail: [email protected]
Internet: www.enerpac.com
0380005-430 © 2005 Enerpac. Subject to change without notice.
Your Enerpac distributor:
ZW Electric Pump Series
The full EnerpacWorkholding line
Cylinders
• Swing Cylinders• Work Supports• Collet-Lok™• Pull Cylinders• Threaded Body• Manifold Mount• Block• Pull Down• Hollow Plunger
Pumps
• Manual • Electric Driven • Compressed Air
Driven
Valves andaccessories
• Manual Directional Valves
• Solenoid DirectionalValves
• Pressure ControlValves
• Flow Control Valves• Hoses and Couplers• Gauges• Fittings• Manifolds
Enerpac Worldwide Locations
AfricaENERPAC Middle East FZEP.O. Box 18004Jebel Ali, DubaiUnited Arab EmiratesTel: +971 (0)4 8872686Fax: +971 (0)4 8872687
Australia Actuant Australia Ltd. Block V Unit 3Regents Park Estate391 Park RoadRegents Park NSW 2143(P.O. Box 261) AustraliaTel: +61 297 438 988Fax: +61 297 438 648
Brazil Power Packer do BrasilLtda.Rua dos Inocentes, 58704764-050 - Sao Paulo (SP)Tel: +55 11 5687 2211Fax: +55 11 5686 5583Toll Free in Brazil:Tel: 0800 891 [email protected]
CanadaActuant CanadaCorporation6615 Ordan Drive, Unit 14-15Mississauga, Ontario L5T1X2Tel: +1 905 564 5749Fax: +1 905 564 0305Toll Free:Tel: +1 800 268 4987Fax: +1 800 461 2456Technical Inquiries:[email protected]
ChinaActuant China Ltd.1F, 269 Fute N. RoadWaigaoqiao Free Trade ZonePudong New DistrictShanghai, 200 131 ChinaTel: +86 21 5866 9099Fax: +86 21 5866 7156
Actuant China Ltd. (Beijing)709A Diyang BuildingXin No. 2Dong San Huan North Rd. Beijing City100028 China Tel: +86 10 845 36166 Fax: +86 10 845 36220
Central and EasternEuropeENERPAC B.V.Galvanistraat 115 P.O. Box 80976710 AB EdeThe NetherlandsTel: +31 318 535 936Fax: +31 318 535 951
FranceENERPAC Une division de ACTUANT France S.A.B.P. 200, Parc d’Activités du Moulin de MassyF-91882 Massy CEDEXFranceTel: +33 1 601 368 68Fax: +33 1 692 037 50
Germany, Austria, Greeceand SwitzerlandENERPAC GmbHP.O. Box 300113D-40401 DüsseldorfGermanyTel: +49 211 471 490Fax: +49 211 471 49 28
IndiaENERPAC Hydraulics (India) Pvt. Ltd.Office No. 9,10 & 11, Plot No. 56, Monarch Plaza, Sector 11, C.B.D. BelapurNavi Mumbai 400614, IndiaTel: +91 22 2756 6090Tel: +91 22 2756 6091Fax: +91 22 2756 6095
ItalyENERPAC S.p.A.Via Canova 420094 Corsico (Milano)Tel: +39 02 4861 111Fax: +39 02 4860 1288
JapanApplied Power Japan Ltd.1-1-11, ShimomaeToda-shiSaitama Pref.Japan 335-0016Tel: +81 484 30 1055Fax: +81 484 30 1066
Middle East, Turkey andCaspian SeaENERPAC Middle East FZEP.O. Box 18004Jebel Ali, DubaiUnited Arab EmiratesTel: +971 (0)4 8872686Fax: +971 (0)4 8872687
Russia and CIS (excl. Caspian SeaCountries) Actuant LLCAdmiral Makarov Street 8125212 Moscow, RussiaTel: +7-095-9809091Fax: +7-095-9809092
SingaporeActuant Asia Pte. Ltd.25 Serangoon North Ave. 5 #03-01 Keppel DigihubSingapore 554914Thomson RoadP.O. Box 114Singapore 915704Tel: +65 64 84 5108
+65 64 84 3737Fax: +65 64 84 5669Toll Free:Tel: +1800 363 7722Technical Inquiries:[email protected]
South KoreaActuant Korea Ltd.3Ba 717,Shihwa Industrial ComplexJungwang-Dong, Shihung-Shi, Kyunggi-DoRepublic of Korea 429-450Tel: +82 31 434 4506Fax: +82 31 434 4507
Spain and PortugalENERPAC C/San José Artesano 8 Pol. Ind.28108 Alcobendas(Madrid) SpainTel: +34 91 661 11 25Fax: +34 91 661 47 89
The Netherlands, Belgium, Luxembourg, Sweden, Denmark, Norway, Finlandand Baltic StatesENERPAC B.V.Galvanistraat 115 P.O. Box 8097, 6710 AB EdeThe NetherlandsTel: +31 318 535 911Fax: +31 318 525 613
+31 318 535 848Technical Inquiries Europe:[email protected]
United Kingdom, IrelandENERPAC Ltd. P.O. Box 33New Romney, TN28 8QFUnited KingdomTel: +44 1527 598 900Fax: +44 1527 585 500
USA, Latin America and CaribbeanENERPAC P.O. Box 32416100 N. Baker Road Milwaukee, WI 53209 USATel: +1 262 781 6600Fax: +1 262 783 9562User inquiries:
+1 800 433 2766Distributor inquiries/orders:
+1 800 558 0530Technical Inquiries:[email protected]
See the EnerpacIndustrial Tools Catalog
for information about otherEnerpac high-force tools. See the Enerpac
Workholding Catalog for information about
other Enerpac products.