© 2008 ibm corporation ibm power systems ibm i and open storage update october 28 th, 2008 vess...
TRANSCRIPT
© 2008 IBM Corporation
IBM Power Systems
IBM i and Open Storage Update
October 28th, 2008
Vess Natchev, [email protected] Blades and VirtualizationIBM Rochester
© 2008 IBM Corporation
IBM Power Systems
Agenda
New: DS4000 Copy Services for IBM i New: SVC support Solution review
– Open storage environment
– Virtualization components
– HMC view
– VIOS view
– IBM i view
– IVM vs. HMC management
– Dual-hosting and MPIO
Support review– Storage subsystems and servers
– Firmware and software
Backups Documentation
© 2008 IBM Corporation
IBM Power Systems
• Production LPAR on IBM Power server or IBM BladeCenter JS12/JS22• IBM i as client of VIOS
• Backup LPAR on IBM Power server or IBM BladeCenter JS12/JS22• IBM i as client of VIOS
• DS4700 or DS4800• FlashCopy or Volume Copy• Full system only
FlashCopy and Volume Copy
Fibre Channel
Fibre Channel
• DS4000 FlashCopy and VolumeCopy are supported by IBM as a client of VIOS on both IBM Power servers and IBM Power blades
• Full-system FlashCopy and VolumeCopy when the production IBM i logical partition (LPAR) is powered off are supported
• Full-system FlashCopy and VolumeCopy when the production IBM i LPAR is in restricted state are supported
• The DS4000 'disable' and 're-create' functions with full-system FlashCopy and VolumeCopy when the production IBM i LPAR is powered off or is in restricted state are supported
• Full-system FlashCopy and VolumeCopy of the production IBM i logical partition (LPAR) after only using the IBM i 6.1 memory flush to disk (quiesce) function are not supported
• Full-system FlashCopy and VolumeCopy when the production IBM i LPAR is running are not supported
• FlashCopy and VolumeCopy of Independent Auxiliary Storage Pools (IASPs) are not supported
• Manual solution• No toolkit available• Not supported by PowerHA
See IBM i Virtualization and DS4000 Read-me First (Ch. 12) – http://www.ibm.com/systems/i/os/
© 2008 IBM Corporation
IBM Power Systems
• Production LPAR on IBM Power server or IBM BladeCenter JS12/JS22• IBM i as client of VIOS
• Backup LPAR on IBM Power server or IBM BladeCenter JS12/JS22• IBM i as client of VIOS
• DS4700 or DS4800• Synchronous Enhanced Remote Mirroring• Full system only
Fibre Channel
Enhanced Remote Mirroring (ERM)
Fibre Channel
• PowerHA for IBM i (Geographic Mirroring, specifically) is also supported and is lead-with solution
• DS4000 ERM is supported by IBM as a client of VIOS on both IBM Power servers and IBM Power blades
• Only Synchronous ERM (DS4000 Metro Mirror) is supported
• Asynchronous ERM (DS4000 Global Copy) or Asynchronous ERM with Write Consistency Group (DS4000 Global Mirror) are not supported
• Full-system Synchronous ERM for a planned switchover (IBM i production LPAR is powered off) is supported
• Full-system Synchronous ERM for an unplanned failover (IBM i production LPAR is running) is supported
• Replication of IASPs is not supported
• Suspending replication and accessing the replicated LUNs on backup site is not supported
• Manual solution• No toolkit available• Not supported by PowerHA
See IBM i Virtualization and DS4000 Read-me First (Ch. 12) – http://www.ibm.com/systems/i/os/
© 2008 IBM Corporation
IBM Power Systems
SVC Support SVC supported for IBM i with VIOS
– IBM i cannot directly attach to SVC
– Similar to other open storage
– Assignment of SVC disk to IBM in VIOS
Storage announcement on October 28th, 2008
– IBM i announcement later in 4Q 2008 with same support
Availability is November 21st, 2008
Supported on all IBM Power servers and BladeCenter JS12/JS22
SVC Entry Edition also supported
© 2008 IBM Corporation
IBM Power Systems
IBM i and Open Storage: Existing Solution Technical Review
© 2008 IBM Corporation
IBM Power Systems
Open Storage Environment
DS4000
EXP810
EXP810
System Manager
RemoteSupport Manager
Modem
IBMAlerts via email
Alerts via email
Dial-in via Modem
EXP810
Admin
IBM Power 520, 550, 560, 570, 595
System Manager – for configuring and managing the DS4000
Remote Support Manager – for monitoring the DS4000
© 2008 IBM Corporation
IBM Power Systems
Virtualization Components Virtual I/O Server (VIOS)– Required to connect to open storage
– Part of PowerVM DASD
– Fibre Channel adapter(s) assigned to VIOS LPAR in HMC
– LUNs are 512B open storage
– Each SAN LUN virtualized directly to IBM i client
– Storage pools not used in VIOS for IBM i
– LUNs virtualized by creating virtual target SCSI devices
Virtual SCSI adapters– Created in HMC
– Server SCSI adapter in VIOS, client SCSI adapter in IBM i
– Multiple pairs supported when HMC used
Optical– IBM i can use any DVD drive connected
to a supported VIOS adapter
– DVD drive in VIOS virtualized directly (OPTxx)
VIOS Host
Virtual SCSI connection
IBM i Client
DS3400DS4700DS4800 DVD
hdiskX LUNsDDxx
/dev/cd0
DVD
OPTxx
IVEVirtual LAN connection
CMNxx
SEA
vtscsiX
vtoptX
512B AIX/VIOS LUNs
© 2008 IBM Corporation
IBM Power Systems
HMC View: VIOS Partition
Partition type is VIOS (not AIX) Physical storage adapter assigned to VIOS At least one Virtual SCSI adapter pair
(server-client) exists per IBM i client Multiple server-client adapter pairs possible
when system is HMC-managed Detailed VIOS information in PowerVM
Operations Guide (http://publib.boulder.ibm.com/infocenter/systems/index.jsp?topic=/iphdx/abstract_pvme_guide.htm)
© 2008 IBM Corporation
IBM Power Systems
HMC View: IBM i Partition
Virtual SCSI client adapter DASD and optical are
accessible through the same VSCSI client adapter
By using multiple adapters, a virtual client LPAR can use DASD from multiple hosts
© 2008 IBM Corporation
IBM Power Systems
VIOS View I
VIOS is a separate partition type Command-line interface unless IVM-managed Not enabled by default on any IBM Power servers
– It is enabled on BladeCenter JS12, JS22 PowerVM Standard or Enterprise Edition must be ordered
– VIOS media
– Enablement code to allow partition type VIOS Use HMC to enter enablement code
– ASMI can also be used
© 2008 IBM Corporation
IBM Power Systems
VIOS View II
Once DS4000 LUNs are available in VIOS, they can be configured as virtual disks for IBM i
– Example: physical LUN hdiskX can be mapped as virtual disk for IBM i by creating a virtual target device (vtscsiX)
VIOS command line is used when HMC-managed– Telnet to VIOS; default administrator ID is padmin
VIOS command examples– lsdev: shows physical and virtual devices
– cfgdev: discovers newly added devices (such as new LUNs)
– mkvdev: creates virtual devices to make resources available to client partitions
• mkvdev –vdev hdisk1 –vadapter vhost0• hdisk1 is LUN to assign to IBM i; vhost0 is VSCSI server adapter in VIOS
for this IBM i partition VIOS commands to virtualize resources are well documented
– IBM Systems Information Center (http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp?topic=/iphb1/iphb1_vios_commandslist.htm)
– PowerVM Operations Guide (http://publib.boulder.ibm.com/infocenter/systems/index.jsp?topic=/iphdx/abstract_pvme_guide.htm)
© 2008 IBM Corporation
IBM Power Systems
IBM i View: Service Tools I
Virtual storage IOA is the VSCSI client adapter Disk units are virtual target devices mapped to LUNs in VIOS
© 2008 IBM Corporation
IBM Power Systems
IBM i View: Service Tools II
No concept of “IBM i protected” and “IBM i unprotected” LUNs with open storage Standard open storage LUNs created, attached to AIX/VIOS-type host Once virtualized by VIOS, LUNs will appear unprotected in IBM i LUNs should not be mirrored in IBM (already protected on SAN) LUNs assigned to ASPs/IASPs as any other disk
© 2008 IBM Corporation
IBM Power Systems
IBM i View: Operating System
Type of virtualized disk is always 6B22 (same as when IBM i is hosting IBM i) Size does not have to match physical disk unit sizes Supported sizes for LUNs through VIOS are 160MB – 2TB
© 2008 IBM Corporation
IBM Power Systems
IVM vs. HMC Management: IVM
Browser-based LPAR and virtualization interface Included with VIOS, but VIOS can be used without managing system with IVM Supported on BladeCenter JS12/JS22, IBM Power 520, 550, 560 (not 570 or 595) Allows GUI management of resources virtualized by VIOS When system is IVM-managed, IBM i partitions must use only virtual resources VIOS must have partition ID = 1 System is managed either by IVM or HMC
© 2008 IBM Corporation
IBM Power Systems
IVM vs. HMC Management: HMC
Browser-based LPAR interface Supported on all IBM Power servers (not supported on BladeCenter JS12 or JS22) IBM i partitions can use a mix or virtual and physical resources GUI for management of VIOS resources not available (IVM), must use VIOS command line
© 2008 IBM Corporation
IBM Power Systems
Dual-hosting and MPIO
IBM i Client LPARs have a dependency on VIOS– VIOS must be running
– VIOS must not be running in service (single-user) mode
When will client LPAR be affected?– Scheduled maintenance
– Hardware upgrades
– Fix Packs
– Release upgrades
– Unplanned downtime
Consider using 2 VIOS LPARs
© 2008 IBM Corporation
IBM Power Systems
Dual VIOS Hosts – Supported
VIOS Host
Virtual SCSI connection
IBM i Client
DS4700DS4800
DVD
hdiskX LUNsDDxx
/dev/cd0
DVD
OPTxx
IVEVirtual LAN connection
CMNxx
SEA
vtscsiX
vtoptX
512B AIX/VIOS LUNs
Duplicate single VIOS environment (shown here)
– Virtual SCSI client/server adapter pair
– Separate set of LUNs in 2nd VIOS
– Same size and number of LUNs
Adapter-level mirroring between 2 sets of disk used in client LPAR
– Mirroring between virtual SCSI client adapters
Client can withstand failure or scheduled downtime in either host
Can be used for multiple clients
Weigh against cost
© 2008 IBM Corporation
IBM Power Systems
MPIO in VIOS – Supported
VIOS Host
Virtual SCSI connection
IBM i Client
DS3400DS4700DS4800
DVD
hdiskX LUNsDDxx
/dev/cd0
DVD
OPTxx
IVEVirtual LAN connection
CMNxx
SEA
vtscsiX
vtoptX
512B AIX/VIOS LUNs
FC
FC
RDAC (Redundant Disk Array Controller) or MPIO driver used in VIOS MPIO configuration created on DS4000
© 2008 IBM Corporation
IBM Power Systems
VIOSAIX client
Hypervisor
vscsitarget
vscsitarget
vscsiinitiator
vscsiinitiator
disk driver
MPIO
SAN
MPIO in client LPAR – Not Supported for IBM i
VIOS
© 2008 IBM Corporation
IBM Power Systems
Support: Storage Subsystems and Servers
These statements apply only to the end-to-end solution of IBM i using DS4000 storage via VIOS virtualization (not to all VIOS support)
Supported storage subsystems (both IBM Power servers and BladeCenter JS12/JS22)
– DS3400 (both SAS and SATA drives; SAS recommended for production LPARs)
– DS4700 (both Fibre and SATA drives, Fibre recommended for production)
– DS4800 (both Fibre and SATA drives, Fibre recommended for production)
– DS8100 (also supported natively by IBM i)
– DS8300 (also supported natively by IBM i)
Supported servers:
– IBM Power 520, 550, 560, 570, 595
– IBM BladeCenter JS12 and JS22
Supported adapters:
– http://www14.software.ibm.com/webapp/set2/sas/f/vios/documentation/datasheet.html (bottom of page)
© 2008 IBM Corporation
IBM Power Systems
Support: Firmware and Software
IBM i 6.1 (latest PTFs recommended as always)
VIOS 1.5.1 Fix Pack 10.1 or later
Power System firmware (service processor) 320_040_031 or later
HMC V7 R3.2.0 or later
DS4000 controller firmware 6.x.x or 7.x.x
DS4000 Storage Manager GUI 9.x or 10.x
AIX/VIOS host kit on DS4000 is required (LUNs for IBM i virtualized by VIOS)
RDAC and MPIO drivers for VIOS supported (transparent to IBM i)
© 2008 IBM Corporation
IBM Power Systems
Backups for IBM i as Client of VIOS
Simplest approach: Regular Tape Backup– Mixing of virtual and direct resources in IBM i client *is* supported
• Does not apply to Power blade environment– Your Choice of direct-attach, SAN-attach, or DLPAR tape sharing
Other backup solutions exist– IBM i save to virtual tape IMGCLG; FTP IMGCLG files to another IBM i partition
– IBM i save to virtual optical IMGCLG, FTP images to VIOS or another IBM i
– IBM i save to file-backed virtual optical in VIOS; VIOS TSM client save over network
– IBM i save to file-backed virtual optical in VIOS; FlashCopy VIOS virtual media LUNs and attach to 2nd VIOS
– FlashCopy (full copy) VIOS LUNs assigned to IBM i; bring up separate IBM i partition under VIOS from copy
– Replicate VIOS LUNs assigned to IBM i; bring up separate IBM i partition under VIOS from copy
© 2008 IBM Corporation
IBM Power Systems
Documentation Performance
– Latest Performance Capabilities Reference manual, Chapter 14.5 – http://www.ibm.com/systems/i/advantages/perfmgmt/resource.html
– Disk Magic strongly recommended for sizing Implementation and support statements
– IBM i Virtualization and DS4000 Read-me First (2nd half) – http://www.ibm.com/systems/i/os/
Implementation – IBM i and Midrange External Storage Redbook (4Q 2008)
VIOS– PowerVM Operations Guide –
http://publib.boulder.ibm.com/infocenter/systems/index.jsp?topic=/iphdx/abstract_pvme_guide.htm
– VIOS command line – http://publib.boulder.ibm.com/infocenter/systems/scope/hw/index.jsp?topic=/iphb1/iphb1_vios_commandslist.htm
– VIOS-only support statements – http://www14.software.ibm.com/webapp/set2/sas/f/vios/documentation/datasheet.html