-Information to assist to choose the correct INPRO unit ............................................................................................. 4
-Oil Supply System Questionnaire ............................................................................................................................. 5
- Oil Suction Transfer Units GPS N - 1 Pump.............................................................................................................. 6
- Oil Suction Transfer Units GPS GE - 2 Pumps ......................................................................................................... 8
- Oil Transfer Pressure Units GP N - 1 Pump ............................................................................................................. 10
- Oil Transfer Pressure Units GP GE - 2 Pumps .......................................................................................................... 12
- Oil Transfer Pressure Units GP M - Two Parts High Pressure System ....................................................................... 14
- Oil Transfer Pressure Units GP N - GC High Flow Systems ....................................................................................... 16
- Oil Transfer Pressure Units FP 1 Pump - FP ZW 2 Pumps System for Tank to Tank Transferring .............................. 18
- Oil Transfer Pressure Units RL 1 Pump - RL ZW 2 Pumps Ring Transferring............................................................. 20
- FP Tank to Tank Transferring FP 1 Pump - FP ZW 2 Pumps Versions for Bio Fuel ..................................................... 22
- RL Transferring Ring System RL 1 Pump - RL ZW 2 Pumps Versions for Bio Fuel .................................................... 24
- ATAM Diesel Transfer Pressure Set...... .....................................................................................................................26
- CAG + Control Cabinet for Multiple Backup Power Generators...... ...........................................................................28
- Monoblock Motorpumps DW and BMF...... ...............................................................................................................29
- Motorpumps Mounted in Baseplate B ..................................................................................................................... 30
- RL Methanol Tranferring Units................................................................................................................................. 31
- Oil Transfer Pressure Units GP-30 NW .................................................................................................................... 32
- Oil Suction Transfer Unit GPS-10 (OUF-88 in the UK) ............................................................................................... 33
- Micro Domestic ...................................................................................................................................................... 34
- Pressure Switches for Oil and Water / Oil Filters ..................................................................................................... 35
- Leak Detector / Oil Collecting Trays ........................................................................................................................ 36
- Pressure Reducing Valves / Inpro Oil Burner Inlet Assembly .................................................................................... 37
- Overflow Valves ...................................................................................................................................................... 38
- Oil Installation Equipment / Solenoid Valves / Automatic Manifolds ......................................................................... 39
- Safety + Overfill Control System for Daily Tanks ..................................................................................................... 40
- Tankalert ECO OIL ................................................................................................................................................... 41
- Level Switch SMMR ............................................................................................................................................... 42
- EDM-40 Remote Level Gauge and Control .............................................................................................................. 43
- Gas Detection Unit GLP-813 with Probe .................................................................................................................. 45
- Fuel Oil Meters Contoil ........................................................................................................................................... 46
- Application Examples:
- GP oil supply to 2 burners ........................................................................................................................ 50
- GP oil supply to 4 burners ........................................................................................................................ 51
- GP automatic oil supply from 2 tanks to 3 burners ................................................................................... 52
- GP GE oil supply to a Power Generator ..................................................................................................... 53
- GP oil supply to 2 Modulating Burners ..................................................................................................... 54
- RL N oil supply to 2 modulating burners .................................................................................................. 55
- RL 8 ZW P - Oil supply to 8 burners ......................................................................................................... 56
- GPS GE Oil supply to 1 burner and 1 power generator .............................................................................. 57
- GPS N Oil supply to 2 burners .................................................................................................................. 58
- GPS version “Druck”: Oil supply suction and pressure system for roof burners ........................................ 59
- FP ZW Oil supply to a daily tank ............................................................................................................... 60
- EDM-40 Example for tank control ............................................................................................................ 61
- Oil transfer to burner and diesel generator with GPS pumpset, storage tank in siphon ............................. 62
4
4 5
Dear Customer, Please fill and send us the next questionnaire, very helpful in the selection for the best oil transferring solution for your installation. Please add also a sketch if possible.
Is this System: For a new installation Yes / No Renovation of an existing installation Yes / No
TANKINSTALLATION
Tank Type Pcs. Litre Ø or height
Underground tank
One free standing and / or lying tank
Special welded tank
Other
BURNER
Total burner / appliances nr Pcs. max kg/h
Total burner power output KW
All the burners in the same room? Yes / No
Different places of assembly Yes / No
PIPING
Piping from the tank to the applianceHeight m
Length m
Piping - if existing Inside Diameter mm
Piping under ground (not observable) Yes / No
Piping visible Yes / No
Piping partially not visible Yes / No
Piping with frequent up & down gradients Yes / No
MOUNTING PLACE FOR THE OIL
PUMP
Close to the tank Yes / No
At the burner room Yes / No
With a large height difference from main tank to appliance
Yes / No
LENGTH OF THE PIPE RUN
Suction sideSuction lift Tank bottom-Pump m
Suction length Tank bottom-Pump m
Drive SidePressure lift Pump-Burner m
Pressure length Pump-Burner m
POWER SUPPLYThree Phase
Single PhaseOUTPUT Free relay Yes / No
Pump system type (your advice)? Single pump........................................................................Models: N � Duplex Pump with automatic switch over.............................Models: GE, ZW
System: � Ring Main System................................................................Models: RL � Dead Leg System �Pressure accumulating System........................Models: GP, DWA
�Suction Pumps.................................................Models: LA-SF, GPS � Main tank to daily service tank transfer................................Models: FP
Medium: If medium is not standard diesel or 28 sec kerosene, please detail or join medium datasheet.Other: ...................................................................................................................................................Need catalogue? Yes / No Bid text needed? Yes / NoDate: Sender:
6
OIL SUCTION TRANSFER UNITSGPS N - 1 PUMP
- (*) There is a 230 single-phase version (W)- 1) 3/4” F Connection, 2) 1” F Connection
MODEL GPS-35 N GPS-70 N GPS-130 N GPS-200 N GPS-350 N GPS-950 N GPS-1500 N
FLOW l/h 30 70 130 200 350 950 1.500
POWER SUPPLY VOLTS230/400
mono phase230/400
tri-phase (*)230/400
tri-phase (*)230/400
tri-phase (*)230/400
tri-phase (*)230/400
tri-phase (*)230/400
tri-phase (*)
MOTORPOWER
C.V. 1/6 1/4 1/3 1/3 1/3 3/4 1
KW 0,12 0,18 0,25 0,25 0,25 0,55 0,75
SUCTIONOD mm PIPING
12 15 15 18 18 1)
252)
252)
RETURN PIPE BURNER
mm ø PIPING
12 15 15 15 18 22 22
TANKCAPACITY
lts. 13,6 35 35 35 163 163 217
MOTORPROTECTION
IP 20 55 55 55 55 55 55
Suction curves and total lengthGPS-35 N / GPS-35 GEW / GPS-70 N / 70 GE / GPS-35 DRUCK
GPS-130 N / 130 GE / GPS-350 N / 350 GET
Suct
ion
in m
. (Su
ctio
n he
ad)
Total length in meter (l+h)kinematic viscositydensity=
Light Oil
UNUSABLE ZONE
MODEL GPS-35 N GPS-70 N GPS-130 N GPS-200 N GPS-350 N GPS-950 N GPS-1500 N
A 260 370 370 370 370 600 600
B 390 640 640 640 640 1.030 1.030
C 360 400 400 400 400 650 650
D 260 — — — — — —
E 40 — — — — — —
F 410 430 430 430 850 850 850
G 460 670 670 670 900 900 900
H 80 120 120 120 220 220 220
Approx. Weight (kg) 10 35 36 36 75 75 75
CD
E
B
HA
FG
6 7
(*) The elements from 7 to 15 belong to Inpro Pumpset
POWER GENERATOR
1. Main storage tank
2. Remote level gauge
3. Floating suction
4. Manhole
5. Ventilation tee.
6. Intake pipe
7. (*) Filter
8. (*) Vacuum gauge
9. (*) by-pass valve
10. (*) electric gear pump
11. (*) anti-return valve
12. (*) Safety / service switches (level)
13. (*) Tank
14. (*) Drip tray
15. (*) Leak detection
16. Quick shut-off valve
17. Burner / boiler
18. Generator unit
Technical Characteristics• Voltage free general alarm outlet.• Output to attach anti-siphon solenoid valve.• Oil leak collector tray with infrared detector.• Safety thermostat (40ºC) for temperature gasification.• Suction pipe couplings for two burners and one for returns.
Accessories and adaptations Art. Nr.
• 8 free relay outputs outlets to control incidents from centralised post / BMS (2-Thermal, 2-Motors ON, Low Level, High Level, Temperature above 40ºC, and Leak detection ON).
21000000000---
• GSM alarm system by means of SMS messages, or connection to modem. 28000000000000
• Adaptation of Suction Groups with greater tank capacity for installations designed for Power Generators, replacing the daily tank.
• Modifications for extreme environments or subject to regulations (Tropicalisation, ATEX, etc.)
• Solenoid valves for siphon installations. 2303000001----
• Additional suction intakes for more burners. 21000000001800
8
OIL SUCTION TRANSFER UNITSGPS GE - 2 PUMPS / TWIN SYSTEM
MODEL GPS-35 GE GPS-70 GE GPS-130 GE GPS-200 GE GPS-350 GE GPS-950 GE GPS-1500 GE
FLOW l/h 30 70 130 200 350 950 1.500
POWER SUPPLY VOLTS230/400
mono phase
230/400 tri-phase (*)
230/400 tri-phase (*)
230/400 tri-phase (*)
230/400 tri-phase (*)
230/400 tri-phase
230/400 tri-phase
MOTORPOWER
C.V. 1/6 1/4 1/3 1/3 1/3 3/4 1½
KW 0,12 0,18 0,25 0,25 0,25 0,55 0,75
SUCTIONmm ø PIPING
12 15 15 18 181)
25 2)
252)
RETURN PIPE BURNER
OD mm PIPING
12 15 15 15 18 22 22
TANKCAPACITY
lts. 24 68 68 68 238 238 245
MOTORPROTECTION
IP 20 55 55 55 55 55 55
CD
E
B
HA
FG
MODEL GPS-35 GE GPS-70 GE GPS-130 GE GPS-200 GE GPS-350 GE GPS-950 GE GPS-1500 GE
A 263 370 370 370 600 600 600
B 370 640 640 640 1.030 1.030 1.030
C 680 760 760 760 960 960 960
D 540 — — — — — —
E 20 — — — — — —
F 400 430 430 430 1.090 1.090 1.090
G 800 870 870 870 1.100 1.100 1.100
H 80 185 185 185 200 200 200
Approx. Weight (kg) 18 48 50 50 97 97 97
Suction curves and total lengthGPS-35 N / GPS-35 GEW / GPS-70 N / 70 GE / GPS-35 DRUCK
GPS-130 N / 130 GE / GPS-350 N / 350 GET
Suct
ion
in m
. (Su
ctio
n he
ad)
Total length in meter (l+h)kinematic viscositydensity=
Light Oil
UNUSABLE ZONE
- (*) There is a 230 single-phase version (W)- 1) 3/4” F Connection, 2) 1” F Connection
8 9
(*) The elements from 7 to 15 belong to Inpro Pumpset
POWER GENERATOR
Technical Characteristics• Voltage free general alarm outlet.• Output to attach anti-siphon solenoid valve.• Oil leak collector tray with infrared detector.• Safety thermostat (40ºC) for temperature gasification.• Suction pipe couplings for two burners and one for returns.
Accessories and adaptations Art. Nr.
• 8 free relay outputs outlets to control incidents from centralised post / BMS (2-Thermal, 2-Motors ON, Low Level, High Level, Temperature above 40ºC, and Leak detection ON).
21000000000---
• GSM alarm system by means of SMS messages, or connection to modem. 28000000000000
• Adaptation of Suction Groups with greater tank capacity for installations designed for Power Generators, replacing the daily tank.
• Modifications for extreme environments or subject to regulations (Tropicalisation, ATEX, etc.)
• Solenoid valves for siphon installations. 2303000001----
• Additional suction intakes for more burners. 21000000001800
1. Main storage tank2. Remote level gauge3. Floating suction4. Manhole5. Ventilation tee.6. Intake pipe7. (*) Filter8. (*) Vacuum gauge9. (*) 2 by-pass valve
10. (*) 2 electric gear pump11. (*) 2 anti-return valve12. (*) Safety / service switches (level)13. (*) Tank14. (*) Drip tray15. (*) Leak detection16. Quick shut-off valve17. Burner / boiler18. Generator unit
10
OIL TRANSFER PRESSURE UNITSGP N - 1 PUMP
MODEL GP-70 N GP-130 N GP-200 N GP-300 N GP-500 N GP-800 N GP-1.500 N
A (cm) 460 460 460 600 600 620 1.170
B (cm) 510 510 610 700 700 720 970
C (cm) 300 300 300 350 350 400 550
Approx. Weight (kg) 18,2 21,8 21,8 31,2 33,6 36 89
Pressure Unit GP-30
Pressure Unit GP-70, GP-130 y GP-200Pressure Unit GP-300, GP-500, GP-800 y GP-1.500
Unusable zone
Delivery pressure 2 bar / 2 kg/cm2
Suct
ion
in m
. (m
anom
etric
hei
ght)
kinematic viscosity= ү37 ~4 c St.density= √15~0,841 kg/l
Light Oil In meters (length + elevation)
UNUSABLE ZONE
MODEL GP-70 N GP-130 N GP-200 N GP-300 N GP-500 N GP-800 N GP-1.500 N
FLOW l/h 70 130 200 300 500 800 1.500
CONNECTION TO THE HYDRAULIC
CIRCUIT(Ø THREAD / Ø MM)
SUCTION 1/2” F 1/2” F 1/2” F 3/4” F 3/4” F 1” F 1” F
DRIVE 3/8” F 3/8” F 3/8” F 1/2” F 1/2” F 1/2” F 3/4” F
POWER SUPPLY VOLTS230/400
tri-phase*230/400
tri-phase*230/400
tri-phase*230/400
tri-phase*230/400 tri-phase
230/400 tri-phase
230/400 tri-phase
MOTORPOWER
C.V. 1/4 1/3 1/3 1/3 1/2 3/4 1½
KW 0,18 0,25 0,25 0,25 0,37 0,55 1,1
MAX.PRESSURE
KG/CM2 3,5 3,5 3,5 4 4 4 4
SAFETY VALVE OPENS AT:
Kg/cm2 4 4 4 4,5 4,5 4,5 4,5
MOTORPROTECTION
IP 55 55 55 55 55 55 55
- (*) There is a 230 single-phase version (W)- Sound level: 58 db (A)
10 11
The elements from 7 to 18 belong to the INPRO pump set
POWERGENERATOR
1. Main storage tank2. EDM-40 Remote level gauge probe3. Floating suction4. EDM-40 Remote level gauge screen5. Overfill prevention kit6. Intake pipe7. Filter8. Vacuum gauge9. Quick shutoff valve10. Electric gear pump11. Anti-return valve12. Quick shutoff valve (Only for GP-1500)13. Pressure gauge14. Dual purpose pressure switch15. Conducted escape safety valve16. Membrane expansion vessel
17. Quick shutoff valve18. Motor protection GP19. Solenoid valve20. Flow limiter21. SMMR 1 Level switch22. Daily tank23. Drip tray (included for GP-800 and above models)24. Leak detection (included for GP-800 and above models)25. Filter26. Pressure reduction valve (using pressure gauge)27. Non-return valve28. Burner29. Burner inlet assembly
Accessories and adaptations Art. Nr.
• Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).
21000000000---
• GSM alarm system by SMS messages, or connection to modem. 28000000000000
• Adaptation of Pressure Group for high pressure, working conditions of up to 6 Kg/cm2 21000000001300
• Leak collector trays with infrared detectors (standard in GP-800 and GP-1500). 2309000000----
• Modifications to adapt to specifically regulated environments with tropicalised equipment or ATEX.
• Solenoid valves with flow limiters, to automate filling in supply tanks for electrical generators. 2303000005----
• Soundproof sheet cabinets with UNE-25 poly-pyramid foam and lock. Manufactured with no back and made-to-measure for each Pressure Group model.
2102000000----
• Assembly of Pressure Groups in IP-55 cabinets for outdoor installation with exterior suction and drive pipe couplings, electric connection presses and ventilation grills.
• Line pressure switch to signal low pressure. 22030000002201
• Power supply failure safety system (timer deferred low pressure stop.) 21000000002300
• Burner inlet assembly 23010000000---
• Modulating burner inlet assembly 23010000001---
12
OIL TRANSFER PRESSURE UNITSGP GE - 2 PUMPS / TWIN SYSTEM
MODEL GP-70 GE GP-130 GE GP-200 GE GP-300 GE GP-500 GE GP-800 GE GP-1.500 GE
FLOW l/h 70 130 200 300 500 800 1.500
CONNECTION TO THE HYDRAULIC
CIRCUIT(Ø THREAD / Ø MM)
SUCTION 1/2” F 1/2” F 1/2” F 3/4” F 3/4” F 1” F 1” F
DRIVE 3/8” F 3/8” F 3/8” F 1/2” F 1/2” F 1/2” F 3/4” F
POWER SUPPLY
VOLTS230/400
tri-phase*230/400
tri-phase*230/400
tri-phase*230/400
tri-phase*230/400 tri-phase
230/400 tri-phase
230/400 tri-phase
MOTORPOWER
C.V. 1/4 1/3 1/3 1/3 1/2 3/4 1½
KW 0,18 0,25 0,25 0,25 0,37 0,55 1,1
MAX.PRESSURE
Kg/cm2 3,5 3,5 3,5 4 4 4 4
SAFETY VALVE OPENS AT:
Kg/cm2 4 4 4 4,5 4,5 4,5 4,5
MOTORPROTECTION
IP 55 55 55 55 55 55 55
- (*) There is a 230 single-phase version (W)- Sound level: 58 db (A)
MODEL GP-70 GE GP-130 GE GP-200 GE GP-300 GE GP-500 GE GP-800 GE GP-1.500 GE
A (cm) 700 700 700 800 800 890 1.455
B (cm) 530 530 630 720 720 750 970
C (cm) 300 300 330 370 370 400 550
Approx. Weight (kg) 31,4 34,4 35,8 43,4 53 89 135
Pressure Unit GP-30
Pressure Unit GP-70, GP-130 y GP-200Pressure Unit GP-300, GP-500, GP-800 y GP-1.500
Unusable zone
Delivery pressure 2 bar / 2 kg/cm2
Suct
ion
in m
. (m
anom
etric
hei
ght)
kinematic viscosity= ү37 ~4 c St.density= √15~0,841 kg/l
Light Oil In meters (length + elevation)
UNUSABLE ZONE
12 13
(*) The elements from 7 to 18 belong to INPRO pump set
POWER GENERATOR
1. Main storage tank2. EDM-40 Remote level gauge probe3. Floating suction4. EDM-40 Remote level gauge screen5. Overfill prevention kit6. Intake pipe7. Filter8. Vacuum gauge9. Quick shutoff valve10. Electric gear pump11. Anti-return valve12. Quick shutoff valve (Only for GP-1500)13. Pressure gauge14. Dual purpose pressure switch15. Conducted escape safety valve16. Membrane expansion vessel
17. Quick shutoff valve18. Motor protection GP19. Solenoid valve20. Flow limiter21. SMMR 1 Level switch22. Daily tank23. Drip tray (included for GP-800 and above models)24. Leak detection (included for GP-800 and above models)25. Filter26. Pressure reduction valve (using pressure gauge)27. Non-return valve28. Burner29. Burner inlet assembly
Accessories and adaptations Art. Nr.
• Free voltage relay output to control from centralised Building Management System, in kit 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON). Standard in GP 800 and GP 1500.
21000000000---
• GSM alarm system by SMS messages, or connection to modem. 28000000000000
• Adaptation of Pressure Group for high pressure, working conditions of up to 6 Kg/cm2 21000000001300
• Leak collector trays with infrared detectors (standard in GP-800 and GP-1500). 2309000000----
• Modifications to adapt to specifically regulated environments with tropicalised equipment or ATEX.
• Solenoid valves with flow limiters, to automate filling in supply tanks for electrical generators. 2303000005----
• Soundproof sheet cabinets with UNE-25 poly-pyramid foam and lock. Manufactured with no back and made-to-measure for each Pressure Group model.
2102000000----
• Assembly of Pressure Groups in IP-55 cabinets for outdoor installation with exterior suction and drive pipe couplings, electric connection presses and ventilation grills.
• Line pressure switch to signal low pressure. 22030000002201
• Power supply failure safety system (timer deferred low pressure stop.) 21000000002300
• Burner inlet assembly 23010000000---
• Modulating burner inlet assembly 23010000001---
14
OIL TRANSFER PRESSURE UNITSGP M - TWO PARTS HIGH PRESSURE SYSTEM
Delivery pressure 2 bar / 2 kg/cm2
Suct
ion
in m
. (m
anom
etric
hei
ght)
In meters (length + elevation)
kinematic viscosity=density= Light Oil
Pressure Unit GP-70, GP-130 y GP-200
Pressure Unit GP-300, GP-500, GP-800 y GP-1.500Unusable zone
MODELGP-70 GP-130 GP-200 GP-300 GP-500 GP-800 GP-1500
MM N MM GE MM N MM GE MM N MM GE MM N MM GE MM N MM GE MM N MM GE MM N MM GE
A 460 460 460 460 460 460 800 800 800 800 620 620 1.170 1.170
B 510 510 510 510 510 510 720 720 720 720 720 720 970 970
C 300 300 300 300 300 300 370 370 370 370 400 400 550 550
D 450 450 450 450 450 450 600 600 600 600 620 620 1.170 1.170
E 470 470 470 470 470 470 500 500 500 500 530 530 900 900
F 280 280 280 280 280 280 350 350 350 350 400 400 530 530
Weight D,E,F 12 13 12 13 12 13 17 18 17 18 17 18 44 45
Weight A,B,C 13 22 16 24 18 26 20 31 22 33 27 58 60 80
CONTROLASSEMBLY
PRESSURE DRIVEASSEMBLY
MODELGP-70 N/GE
GP-130N/GE
GP-200N/GE
GP-300N/GE
GP-500 N/GE
GP-800 N/GE
GP-1.500 N/GE
FLOW l/h 70 130 200 300 500 800 1.500
CONNECTION TO THE HYDRAULIC
CIRCUIT(Ø THREAD / Ø MM)
SUCTION 1/2” F 1/2” F 1/2” F 3/4” F 3/4” F 1” F 1” F
DRIVE 3/8” F 3/8” F 3/8” F 1/2” F 1/2” F 1/2” F 3/4” F
POWER SUPPLY VOLTS230/400
tri-phase*230/400
tri-phase*230/400
tri-phase*230/400
tri-phase*230/400 tri-phase
230/400 tri-phase
230/400 tri-phase
MOTORPOWER
C.V. 1/4 1/3 1/3 1/2 1/2 3/4 1½
KW 0,18 0,25 0,25 0,37 0,37 0,55 1,1
MAX.PRESSURE
Kg/cm2 3,5 3,5 3,5 4 4 4 4
SAFETY VALVE OPENS AT:
Kg/cm2 4 4 4 4,5 4,5 4,5 4,5
MOTORPROTECTION
IP 55 55 55 55 55 55 55
14 15
Accessories and adaptations Art. Nr.
• Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).
21000000000---
• GSM alarm system by SMS messages, or connection to modem. 28000000000000
• Adaptation of Pressure Group for high pressure, working conditions of up to 6 Kg/cm2 21000000001300
• Leak collector trays with infrared detectors (standard in GP-800 and GP-1500). 2309000000----
• Modifications to adapt to specifically regulated environments with tropicalised equipment or ATEX.
• Solenoid valves with flow limiters, to automate filling in supply tanks for electrical generators. 2303000005----
• Soundproof sheet cabinets with UNE-25 poly-pyramid foam and lock. Manufactured with no back and made-to-measure for each Pressure Group model.
2102000000----
• Assembly of Pressure Groups in IP-55 cabinets for outdoor installation with exterior suction and drive pipe couplings, electric connection presses and ventilation grills.
• Line pressure switch to signal low pressure. 22030000002201
• Power supply failure safety system (timer deferred low pressure stop.) 21000000002300
• Burner inlet assembly 23010000000---
• Modulating burner inlet assembly 23010000001---
1. Main storage tank2. Remote level gauge3. Floating suction4. Ventilation Tee5. Manhole6. Intake pipe7. Filter8. Vacuum gauge9. Quick shutoff valve10. Electric gear pump11. Anti-return valve12. Quick shutoff valve (Only for GP-1500)
13. Pressure gauge14. Dual purpose pressure switch15. Conducted escape safety valve16. Membrane expansion vessel17. Quick shutoff valve18. Electric control system for the pressure unit19. Pressure reduction valve (using pressure gauge)20. Non-return valve21. Burner 22. Drip tray23. Leak detection
Mor
e th
an 4
0 m
ts.
Control assembly
Pressure drive assembly
16
OIL TRANSFER PRESSURE UNITSGP N - GC HIGH FLOW SYSTEMS
MODELGP-2200 NTGP-2200 GE
GP-3200 NTGP-3200 GE
GP-4200 NTGP-4200 GE
GP-6500 NTGP-6500 GE
GP-8500 NTGP-8500 GE
GP-12000 NTGP-12000 GE
FLOW l/h 2.200 3.200 4.200 6.500 8.500 12.000
CONNECTION TO THE HYDRAULIC
CIRCUIT(Ø THREAD / Ø MM)
SUCTION 1” F 1” 1/2 F 1” 1/2 F 2” F 2” F 2” F
DRIVE 3/4” F 1” F 1” 1/4 F 1” 1/2 F 1” 1/2 F 2” F
POWER SUPPLY VOLTIOS230/400 tri-phase
230/400 tri-phase
230/400 tri-phase
230/400 tri-phase
230/400 tri-phase
230/400 tri-phase
MOTOR POWERC.V. 2 2 3 4 4 5,5
KW 1,5 1,5 2,2 3 3 4
MAX.PRESSURE
Kg/cm2 3,5 3,5 3,5 3,5 4 4
SAFETYVALVE OPENS AT:
Kg/cm2 4,5 4,5 4,5 4,5 4,5 4,5
PIPING SUCT/PRES 1½” / 1” 2” / 1¼” 2½” / 1½” 2½” / 1½” 3” / 2” 3” / 2½”
MOTORPROTECTION
IP 55 55 55 55 55 55
MODEL GP-2200 GC GP-3200 GC GP-4200 GC GP-6500 GC GP-8500 GC GP-12000 GC
A 1.150 1.150 1.150 1.150 1.150 1.150
B 910 910 910 910 910 910
C 1.610 1.610 1.610 1.610 1.610 1.610
Approx. Weight NT (kg) 99 105 110 120 135 140
Approx. Weight GE (kg) 117 127 136 147 164 171
Unusable zone
0
1
2
3
MAX.
4
5
6
5 10 15 20 25 30 35 40 45 50 55
Light Oil kinematic viscosity = �37~ 4 c St.
density = χ15 ~ 0,841 κγ./Λ.
Suct
ion
in m
. (m
anom
etric
hei
ght)
16 17
POWER GENERATOR
1. Main storage tank2. Remote level gauge3. Floating suction4. Ventilation Tee5. Manhole6. Suction pipe7. Filter8. Vacuum gauge9. Quick Shut off valve10. Electric gear pump11. Anti-return valve12. Quick shutoff valve (only for GP-1500)13. Pressure gauge14. Dual-purpose pressure switch15. Conducted escape safety valve
16. Membrane expansion vessel17. Quick shutoff valve18. Electric control system for the pressure unit (alternative command)19. Electrically operated valve20. Flow limiter21. SMMR 1 level switch22. Daily tank23. Drip tray24. Leak detector25. Filter26. Pressure gauge27. Non-return valve28. Burner
Accessories and adaptations Art. Nr.
• Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).
21000000000---
• GSM alarm system by SMS messages, or connection to modem. 28000000000000
• Adaptation of Pressure Group for high pressure, working conditions of up to 6 Kg/cm2 21000000001300
• Leak collector trays with infrared detectors (standard in GP-800 and GP-1500). 2309000000----
• Modifications to adapt to specifically regulated environments with tropicalised equipment or ATEX.
• Solenoid valves with flow limiters, to automate filling in supply tanks for electrical generators. 2303000005----
• Soundproof sheet cabinets with UNE-25 poly-pyramid foam and lock. Manufactured with no back and made-to-measure for each Pressure Group model.
2102000000----
• Burner inlet assembly 23010000000---
• Modulating burner inlet assembly 23010000001---
18
OIL TRANSFER PRESSURE UNITSFP ONE PUMP - FP ZW TWO PUMPS
System for Tank to Tank Transferring
UNUSABLE ZONE
FP 10FP 23 - 41
FP 90 - 570
6
5
4
3
2
1
00 3 6 9 12 15 18 21 24 27 30 33 36 39 42 45
Suct
ion
in m
. (m
anom
etric
hei
ght)
In meters (length + elevation)
MODELFP 10 FP 23 FP 41 FP 90 FP 120 FP 240 FP 360 FP 570
N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW
A 595 870 595 870 595 870 595 890 595 890 1.200 1.200 1.200 1.300 1.200 1.300
B 575 720 575 720 575 720 575 790 575 790 1.000 1.000 1.000 1.000 1.000 1.000
C 240 240 240 300 240 300 240 350 240 400 500 850 500 850 500 850
APPROX. WEIGHT
(KG)14 31 16 35 16 35 24 68 28 79 100 200 130 230 195 300
MODEL FP 10 FP 23 FP 41 FP 90 FP 120 FP 240 FP 360 FP 570
FLOW l/h 100 260 460 900 1.400 2.100 3.400 5.300
POWER SUPPLY VOLTS 400* 400* 400* 400 400 400 400 400
MOTORPOWER
KW 0,25 0,25 0,25 0,55 0,55 2,2 3 3
CV 1/3 1/3 1/3 3/4 3/4 3 4 4
MOTOR r.p.m. 1.400 1.400 1.400 1.400 1.400 1.400 1.400 1.400
CONNECTION TO THE HYDRAULIC
CIRCUIT(Ø THREAD / Ø MM)
SUCTION 1/2” F 1/2” F 1/2” F 1” F 1” F DN 32 DN 40 DN 40
DRIVE 1/2” F 1/2” F 1/2” F 1” F 1” F DN 32 DN 40 DN 40
OVERPRESSURE 1/2” F 1/2” F 1/2” F 3/4” F 1” F DN 32 DN 40 DN 40
SOUNDLEVEL
dB (A) 58 58 58 58 58 58 58 58
MOTORPROTECTION
IP 55 55 55 55 55 55 55 55
- (*) There is a 230 single-phase version power supply version (W)- For other capacity and mediums, please consult.- Threaded Flanges DIN 2566
18 19
7
3
9
8
6
2
1
4
5
List of parts in FP MODELS
One pump versions FP 10 - FP 570Motor, flange, coupling, gear pump, overpressure valve, filter in suction side and vacuum meter, rigid pipe connections (steel), mounted in wall fixing frame until FP 120. Above FP 240, angle frame floor deck. Ready electrical assembly, switch, motor protection and connection for Level Switch. For easy connection we recommended SMMR1 level switch for your tank.
Two pumps versions FP 10 - FP 570 ZW2 motors, flange, coupling, 2 gear pumps, overpressure valve, filter in suction side and vacuum meter, rigid pipe connections (steel), mounted in wall fixing frame until FP 120. Above FP 240, angle frame floor deck. Ready electrical assembly, electrical alternative switch, motor protection, and connection for Level Switch.For easy connection we recommend SMMR1 Level Switch for your tank.
Special Non-Ferrous metal free versions upon request.
For higher viscosities please consult for the suitable FP system specification.
Accessories and adaptations Art. Nr.
• Oil failure control system, to protect gears running with an empty tank. 21000000001500
• Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).
21000000000---
• GSM alarm system by SMS messages, or connection to modem. 28000000000000
• Adaptation of Pressure Group for high pressure, working conditions of up to 4,5 Kg/cm2 210000000013--
• Leak collector trays with infrared detectors (standard in FP 240 and above) 2309000000----
• Modifications to adapt to specifically regulated environments (tropicalised equipment or ATEX.)
• Solenoid valves with flow limiters, to automate filling in supply tanks for electrical generators. 2303000005----
• Soundproof sheet cabinets with UNE-25 poly-pyramid foam and lock. Manufactured with no back and made-to-measure for each Pressure Group model.
2102000000----
• Assembly of Pressure Groups in IP-55 cabinets for outdoor installation with exterior suction and drive pipe couplings, electric connection presses and ventilation grills.
• Line pressure switch to signal low pressure. 22030000002201
1.- Pump Type FP2.- Main tank3.- Daily tank4.- Suction pipe5.- Overpressure pipe6.- Overflow pipe7.- SMMR 1 Level Switch8.- Oil supply pipe9.- Control line
20
OIL TRANSFER PRESSURE UNITSRL ONE PUMP - RL ZW TWO PUMPS
Ring transferring
6
5
4
3
2
1
00 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
RL 0RL 1-2
RL 3-10
UNUSABLE ZONE
Elev
atio
n in
m. (
man
omet
ric h
eigh
t)
In meters (length + elevation)
MODEL RL 0 RL 1 RL 2 RL 3 RL 4 RL 5 RL 6 RL 7 RL 8 RL 9 RL 10
MAX. FLOW l/h 100 260 460 900 1.400 2.100 3.400 5.300 7.500 10.500 12.000
SUPPLY FLOW l/h 65 150 300 600 900 1.450 2.300 3.600 4.900 7.000 8.000
SUPPLY VOLTAGE
VOLT 400* 400 400 400 400 400 400 400 400 400 400
MOTORPOWER
KW 0,25 0,25 0,25 0,55 0,55 2,2 3 3 4 4 4
CV 1/3 1/3 1/3 3/4 3/4 3 4 4 5,5 5,5 5,5
MOTOR r.p.m 1.420 1.420 1.420 1.420 1.420 1.420 1.420 1.420 1.420 1.420 1.420
CONNECTION TO THE HYDRAULIC
CIRCUIT (Ø THREAD / Ø MM)
SUCTION 1/2” F DN 20 DN 20 DN 25 DN 25 DN 32 DN 40 DN 40 DN 50 DN 50 DN 65
DRIVE 3/8” F DN 20 DN 20 DN 25 DN 25 DN 32 DN 40 DN 40 DN 40 DN 40 DN 50
OVERPRESSURE 1/2” F 1/2” F 1/2” F 3/4” F 1” F DN 32 DN 40 DN 40 DN 40 DN 40 DN 40
MAX.SUCTION
m 5 5 5 5 5 5 5 5 5 5 5
SECURITY VALVE OPENS AT:
bar 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5
MOTORPROTECTION
IP 55 55 55 55 55 55 55 55 55 55 55
- (*) There is a 230 single-phase version (W)- Threaded Flanges DIN 2566
MODELRL 0 RL 1 RL 2 RL 3 RL 4 RL 5 RL 6 RL 7 RL 8 RL 9 RL 10
N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW
A 595 870 595 870 595 870 870 890 870 890 1.200 1.300 1.200 1.300 1.200 1.300 1.200 1.300 1.200 1.300 1.200 1.300
B 575 720 575 720 575 720 720 790 720 790 1.000 1.000 1.000 1.000 1.000 1.000 1.100 1.100 1.100 1.100 1.100 1.100
C 240 300 240 300 240 300 300 350 300 400 500 850 500 850 500 850 500 850 500 850 500 850
APPROX. WEIGHT
(KG)15 32 17 36 17 36 29 73 35 84 100 130 105 135 110 145 120 150 125 155 130 165
20 21
Contents list for RL Transferring Ring System One Pump Versions
Motor, flange, clutch, coupling, gear pump, filter, vacuumeter, pressure gange, pressure switch, security for pipe breaking or no fuel failure, motor protection with contactor, main switch, failure indicator, time delay pressure switch control for first runnings, overpressure security valve, flange or G inside tread connection to hydraulic circuit, free relay connections for failure signals out of the RL pump. All ready, mounted, fixed and electrically connected in wall plate. RL 5 and above in angle workframe.
Additionally, in Two Pumps versions:Motor, flange, clutch, coupling, gear pump, Motor protection with contactor, alternating motor steering in time swap over.“IM” system to stop pumps when all burners are off is included (optional for RL-one pump).
Special Non-Ferrous metal free versions upon request.
Reference mark:To maintain security disposals from DIN norm, the pressure regulation valve must be placed in the return pipe to tank in proximity to the tank.
1
2
3
4
5
6
78
9 910 11 12
13
14
15
16 16
17
18
19 19
17
18
19
17
18
20
Accessories and adaptations Art. Nr.
• IM system to stop pumps when all burners are off (optional for RL-N) 21010000010010
• Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).
21000000000---
• GSM alarm system by SMS messages, or connection to modem. 28000000000000
• Adaptation of Pressure Group for high pressure, working conditions of up to 6,5 Kg/cm2 21000000001300
• Leak collector trays with infrared detectors (standard in RL-4 and above). 2309000000----
• Modifications to adapt to specifically regulated environments (tropicalised equipment or ATEX.)
• Solenoid valves with flow limiters, to automate filling in supply tanks for electrical generators. 2303000005----
• Soundproof sheet cabinets with UNE-25 poly-pyramid foam and lock. Manufactured with no back and made-to-measure for each Pressure Group model.
2102000000----
• Assembly of Pressure Groups in IP-55 cabinets for outdoor installation with exterior suction and drive pipe couplings, electric connection presses and ventilation grills.
• Line pressure switch to signal low pressure. 22030000002201
• Power supply failure safety system (timer deferred low pressure stop.) 21000000002300
1. Main storage tank2. Suction pipe3. Level gauge probe4. EDM-40 level gauge indicator5. Overfill safety system6. Intake pipe7. Filter8. Vacuum gauge9. 4 Non-return valve10. 2 Electric gear pumps11. Pressure gauge12. Low level pressure switch13. Conducted escape safety valve14. Quick shutoff valve15. Electric control system with timer16. Degassing bottle17. Quick shutoff valve18. Burner19. Aluminium selfclean filter20. Overflow valve
22
FP TANK TO TANK TRANSFERRINGFP ONE PUMP-FP ZW TWO PUMPS
Versions for Bio Fuel1)
MODELFP 10 FP 23 FP 41 FP 90 FP 120 FP 240 FP 360 FP 570
N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW
A 595 870 595 870 595 870 595 890 595 890 1.200 1.200 1.200 1.300 1.200 1.300
B 575 720 575 720 575 720 575 790 575 790 1.000 1.000 1.000 1.000 1.000 1.000
C 240 240 240 300 240 300 240 350 240 400 500 850 500 850 500 850
APPROX. WEIGHT
(KG)14 31 16 35 16 35 24 68 28 79 100 200 130 230 195 300
MODEL FP 10 FP 23 FP 41 FP 90 FP 120 FP 240 FP 360 FP 570
MAX. FLOW l/h 100 260 460 900 1.400 2.100 3.400 5.300
SUPPLY VOLTAGE VOLT 400* 400* 400* 400 400 400 400 400
MOTOR POWERKW 0,25 0,25 0,25 0,55 0,55 2,2 3 3
C.V. 1/3 1/3 1/3 3/4 3/4 3 4 4
MOTOR r.p.m. 1.400 1.400 1.400 1.400 1.400 1.400 1.400 1.400
SECURITY VALVE OPENS AT
bar 4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5
CONNECTION TO THE HYDRAULIC
CIRCUIT
SUCTION 1” F 1” F 1” F DN 32 DN 32 DN 50 DN 50 DN 50
DRIVE 1” F 1” F 1” F DN 32 DN 32 DN 50 DN 50 DN 50
OVERPRESSURE 3/4” F 3/4” F 3/4” F 1” F 1” F DN 40 DN 40 DN 40
MOTOR PROTECTION
IP 55 55 55 55 55 55 55 55
(*) Also available in 230 single phase versions (W/WD= 230 V. single phase version; D= 400 V. triphase versions).- For other capacity and mediums, please consult.- ZW: Two pumps versions1)For viscosities till 38 mm2/s (40ºC)
- Technical data can be modified without prior advise.
List of parts in FP models, versions for Bio-Fuel
One pump versions FP 10 - FP 570Motor, flange, coupling, gear pump, overpressure valve, filter in suction side and vacuum meter, rigid pipe connections (steel), mounted in wall fixing frame until FP 120. Above FP 240, angle frame floor deck. Ready electrical assembly, switch, motor protection and connection for Level Switch. For easy connection we recom-mended SMMR1 level switch for your tank.
Two pumps versions FP 10 - FP 570 ZW2 motors, flange, coupling, 2 gear pumps, overpressure valve, filter in suction side and vacuum meter, rigid pipe connections (steel), mounted in wall fixing frame until FP 120. Above FP 240, angle frame floor deck. Ready electrical assembly, electrical alternative switch, motor protection, and connection for Level Switch. For easy connection we recommend SMMR1 Level Switch for your tank.
Manufactured and tested under DIN 12.514-1.
For higher viscosities please consult for the suitable FP system specification.
22 23
7
3
9
8
6
2
1
4
5
1. Pump Type FP2. Main tank3. Daily tank4. Suction pipe5. Overpressure pipe6. Overflow pipe7. SMMR 1 Level Switch8. Oil supply pipe9. Control line
Accessories and adaptations Art. Nr.
• Special non –ferrous metal free versions upon request.
• Standard motor power ready for viscosities till 38mm2/s (40ºC). For other, please consult.
• Oil failure control system, to protect gears running with an empty tank. 21000000001500
• Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).
21000000000---
• GSM alarm system by SMS messages, or connection to modem. 28000000000000
• Adaptation of Pressure Group for high pressure, working conditions above 4,5 Kg/cm2. 210000000013--
• Leak collector trays with infrared detectors (standard in RL 4 and above). 2309000000----
• Modifications to adapt to specifically regulated environments (tropicalised equipment or ATEX).
• Solenoid valves with flow limiters, to automate filling in supply tanks for electrical generators. 2303000005----
• Soundproof sheet cabinets with UNE-25 poly-pyramid foam and lock. Manufactured with no back and made-to-measure for each Pressure Group model.
2102000000----
• Assembly of Pressure Groups in IP-55 cabinets for outdoor installation with exterior suction and drive pipe couplings, electric connection presses and ventilation grills.
• Line pressure switch to signal low pressure. 22030000002201
24
RL TRANSFERRING RING SYSTEM RL ONE PUMP-RL ZW TWO PUMPS
Versions for Bio Fuel1)
MODEL N / ZW RL 0 RL 1 RL 2 RL 3 RL 4 RL 5 RL 6 RL 7 RL 8 RL 9 RL 10
MAX. FLOW l/h 100 260 460 900 1.400 2.100 3.400 5.300 7.500 10.500 12.000
SUPPLY FLOW l/h 65 150 300 600 900 1.450 2.300 3.600 4.900 7.000 8.000
SUPPLY VOLTAGE
VOLT 400* 400 400 400 400 400 400 400 400 400 400
MOTORPOWER
KW 0,25 0,25 0,25 0,55 0,55 2,2 3 3 4 4 4
CV 1/3 1/3 1/3 3/4 3/4 3 4 4 5,5 5,5 5,5
MOTOR r.p.m. 1.400 1.400 1.400 1.400 1.400 1.400 1.400 1.400 1.400 1.400 1.400
CONNECTION TO THE HYDRAULIC
CIRCUIT
SUCTION DN 20 DN 25 DN 25 DN 32 DN 32 DN 50 DN 50 DN 50 DN 40 DN 50 DN 65
DRIVE DN 20 DN 25 DN 25 DN 32 DN 32 DN 50 DN 50 DN 50 DN 40 DN 40 DN 50
OVERPRESSURE 1/2”F 3/4”F 3/4”F 1”F 1”F DN 40 DN 40 DN 40 DN 40 DN 40 DN 40
SECURITY VALVE OPENS AT
bar 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5 6,5
MOTORPROTECTION
IP 55 55 55 55 55 55 55 55 55 55 55
MODELRL 0 RL 1 RL 2 RL 3 RL 4 RL 5 RL 6 RL 7 RL 8 RL 9 RL 10
N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW N ZW
A 595 870 595 870 595 870 870 890 870 890 1.200 1.300 1.200 1.300 1.200 1.300 1.200 1.300 1.200 1.300 1.200 1.300
B 575 720 575 720 575 720 720 790 720 790 1.000 1.000 1.000 1.000 1.000 1.000 1.100 1.100 1.100 1.100 1.100 1.100
C 240 300 240 300 240 300 300 350 300 400 500 850 500 850 500 850 500 850 500 850 500 850
APPROX. WEIGHT
(KG)15 32 17 36 17 36 29 73 35 84 100 130 105 135 110 145 120 150 125 155 130 165
Contents list for RL Transferring Ring System One Pump Versions
Motor, flange, clutch, coupling, gear pump, filter, vacuumeter, pressure gange, pressure switch, security for pipe breaking or no fuel failure, motor protection with contactor, main switch, failure indicator, time delay pressure switch control for first runnings, overpressure security valve, flange or G inside tread connection to hydraulic circuit, free relay connections for failure signals out of the RL pump. All ready, mounted, fixed and electrically connected in wall plate. RL 5 and above in angle workframe.
“IM” system to stop pumps when all burners are off is optional for RL-N.
Additionally, in Two Pumps versions:Motor, flange, clutch, coupling, gear pump, Motor protection with contactor, alternating motor steering in time swap over.“IM” system to stop pumps when all burners are off is included (optional for RL-N).
Manufactured and tested under DIN 12.514-1 (except RL 30 BIO).
For higher viscosities please consult for the suitable RL system specification.
Reference mark:To maintain security disposals from DIN norm, the pressure regulation valve must be placed in the return pipe to tank in proximity to the tank.
24 25
Accessories and adaptations Art. Nr.
• Special non –ferrous metal free versions upon request.
• Standard motor power ready for viscosities till 38mm2/s (40ºC). For other, please consult.
• IM system to stop pumps when all burners are off (optional for RL one pump). 21010000010010
• Free voltage relay output to control from centralised Building Management System, in kit 3, 4 or 6 signals (2-thermal, motors 1 or 2 ON, low pressure and Leak safety ON).
21000000000---
• GSM alarm system by SMS messages, or connection to modem. 28000000000000
• Adaptation of Pressure Group for high pressure, working conditions above 6,5 Kg/cm2. 210000000013--
• Leak collector trays with infrared detectors (standard in RL-4 and above). 2309000000----
• Modifications to adapt to specifically regulated environments (tropicalised equipment or ATEX).
• Solenoid valves with flow limiters, to automate filling in supply tanks for electrical generators. 2303000005----
• Soundproof sheet cabinets with UNE-25 poly-pyramid foam and lock. Manufactured with no back and made-to-measure for each Pressure Group model.
2102000000----
• Assembly of Pressure Groups in IP-55 cabinets for outdoor installation with exterior suction and drive pipe couplings, electric connection presses and ventilation grills.
• Line pressure switch to signal low pressure. 22030000002201
• Power supply failure safety system (timer deferred low pressure stop). 21000000002300
1. RL Heating Oil Transferring Ring System.2. Feeding pipe line.3. Pressure regulation valve type DRV 1.4. Return pipe line5. Overpressure pipe line.
26
ATAM Diesel Transfer Pressure Setfor Power Generation Systems
Suc
tion
in m
. (m
anom
etric
hei
ght)
Length + elevation in m.
MODELATAM
180 GETATAM
300 GETATAM
450 GETATAM
700 GETATAM
900 GETATAM
1.200 GETATAM
1.500 GETATAM
2.100 GET
A 700 700 700 800 890 890 1.115 1.115
B 550 550 550 720 750 750 970 970
C 300 300 300 350 400 400 500 500
WEIGHTAPPROX. (kg)
31 34 34 65 80 90 150 160
MODELO ATAM 180 GET 300 GET 450 GET 700 GET 900 GET 1.200 GET 1.500 GET 2.100 GET
FLOW l/h 180 300 450 700 900 1.200 1.500 2.100
MOTORPOWER
V 400 400 400 400 400 400 400 400
kW 0,25 0,25 0,25 0,33 0,55 0,55 0,55 1
MOTORSPEED
r.p.m 1.400 1.400 1.400 1.400 1.400 1.400 1.400 1.400
CONNECTION TO
HYDRAULIC CIRCUIT
SUCTION 1/2” F 1/2” F 1/2” F 3/4” F 3/4” F 3/4” F 1” F 1” F
DRIVE 1/2” F 1/2” F 1/2” F 3/4” F 3/4” F 3/4” F 1” F 1” F
OVERPRESSURE 1/2” F 1/2” F 1/2” F 3/4” F 3/4” F 3/4” F 1” F 1” F
SECURITY VALVEOPENS AT:
bar 4,5 4,5 4,5 4,5 4,5 4,5 4,5 4,5
SOUND LEVEL dB (A) 58 58 58 58 58 58 58 58
MOTORPROTECTION
IP 55 55 55 55 55 55 55 55
- Produced and tested under DIN 12.514-1 standard
26 27
28
CAG + Control Cabinet for MultipleBackup Power Generators
DESCRIPTION
The INPRO CAG+ Control Cabinet for Multiple Backup Power Generators is the perfect complement to INPRO transfer systems for diesel oil ATAM-GET. Its main component is a controller with multiple inputs and outputs analog / digital which can be defined for each installation.
• It will allow to safety designer ilimited manoeuver possibilities for tanks, pump systems, overflow, transfer pumps, solenoid valves, alarms, as the management is via software.
• 2nd backup relay logic design overriding the automatic controller, for safety critical points at the installation.• Monitor levels at daily tanks.• Touch screen 5,7” with Mod Bus or Ethernet TCP IP communication protocol.
TECHNICAL FEATURES
The CAG+ control system can manage 1, 2 or 3 filling areas depending on the configuration.
The display shows the level of daily tanks, the status of pumps, valves, etc… giving the possibility of performing either manual fillings or automatic fillings, well as different maintenance tests, essential feature to have always those backup installation ready to enter into force.
It consists of a touch screen 5.7” monochrome with Mod Bus communication capability with SCADA. Color screen, TCP-IP communication protocol are also available as additional requirement.
TECHNICAL SPECIFICATIONS
• Voltage: 230 V• RCBO (Residual Current Breaker with Overcurrent): 40 A• MCB (Mains Circuit Breaker).: 40 A• Pump control (depending on project)• Maneuver (according to project)• Tanks control (according to project)• Solenoid (according to project)
28 29
MONOBLOCK MOTORPUMPS DW AND BMF
C.V. 5 Bar CODE
BMF2 3/8" 0,12 120 l/h 33000001011210
BMF3 3/8" 0,18 210 l/h 33000000912110
BMF4 3/8" 0,25 240 l/h 33000000012410
BMF5 1/2" 0,35 320 l/h 33000000113210 C.V. 10 Bar CODE
BMF10 3/4" 0,35 600 l/h 33000000116010 0,50 580 l/h 33000000215810
BMF15 3/4" 0,50 900 l/h 33000000219010 0,75 850 l/h 33000000318510
BMF25 3/4" 0,75 1.500 l/h 33000000321510 1 1.400 l/h 33000001421410
BMF35 1" 1 2.100 l/h 33000001422110 1,50 2.000 l/h 33000000043210
BMF50 1" 1,50 3.000 l/h 33000000423010 2 2.900 l/h 33000000522910
BMF60 11/4" 2 3.600 l/h 33000000523610 2,50 3.400 l/h 33000001623410- Bypass valve included.- Tri-phase motor at 1.400 r.p.m. (for singlephase versions, please consult).
MOTORPUMP GEAR TYPE FOR FUEL TRANSFER- Self-priming, special treated helical gears for the pump to be silent.- Casting body (shell moulding).- Great robustness Tri-phase motor.- Direction of rotation, can be changed either counterclockwise or clockwise with inverter.
- Bench cast iron and suitable for standard motors.- Fully balanced, robust and silent, not requiring any maintenance.- Its powerful engine avoid problems with low temperatures fuel startups .
MOTOR PROT CLASS. FLOW POWER SUPPLY CODE
1/4 CV IP 55 120 l/h 3 x 400 Vca 33000000014120
1/3 CV IP 55 250 l/h 3 x 400 Vca 33000000013250
1/2 CV IP 55 500 l/h 3 x 400 Vca 33000000012500
1 CV IP 55 1.700 l/h 3 x 400 Vca 33000000011700
2 CV IP 55 1.700 l/h 3 x 400 Vca 33000000021700
3 CV IP 55 3.500 l/h 3 x 400 Vca 33000000033500
- Power Supply: 230 Vac Single phase 50 Hz- Consumption: 150 W
- Size: 310 x 200 x 210 mm- Max. pressure: 10 bar
MODEL MAX. FLOW AT 2 bar SUCTION PRESSURE RETURN BYPASS
OPEN ATWEIGHT
KG CODE
DW 60 By-pass 60 l/h G 1/4" G 1/8" - 4 bar 4,65 33000000006020
DW 60 Ring S 60 l/h G 1/4" G 1/8" G 1/4" - 4,65 33000000006021
DW 120 By-pass 120 l/h G 1/4" G 1/8" - 4 bar 5 33000000011220
DW 120 Ring S 120 l/h G 1/4" G 1/8" G 1/4" - 5 33000000011221
30
MOTORPUMPS MOUNTED IN BASEPLATE B
C.V. 2,5 Bar 5 Bar C.V. 10 Bar C.V. 2,5 Bar 5 Bar C.V. 10 Bar
B3 1/2" 0,25 246 l/h 228 l/h 0,25 192 l/h B200 21/2" 5,50 12.900 l/h 12.720 l/h 7,50 12.300 l/h
B5 1/2" 0,25 360 l/h 348 l/h 0,35 312 l/h B250 21/2" 5,50 15.600 l/h 15.480 l/h 10,00 15.000 l/h
B10 3/4" 0,35 720 l/h 708 l/h 0,50 660 l/h B300 21/2" 7,50 19.200 l/h 18.840 l/h 10,00 18.120 l/h
B15 3/4" 0,50 1.050 l/h 1.020 l/h 0,75 960 l/h B350 21/2" 7,50 22.200 l/h 21.900 l/h 15,00 21.000 l/h
B25 3/4" 0,75 1.500 l/h 1.488 l/h 1,00 1.320 l/h B400 21/2" 10 25.200 l/h 24.900 l/h 15,00 24.300 l/h
B40 1" 1 2.580 l/h 2.556 l/h 1,50 2.400 l/h B450 3" 10 28.500 l/h 28.000 l/h 15,00 27.300 l/h
B50 11/2" 1,50 3.240 l/h 3.120 l/h 2,00 3.000 l/h B500 3" 15 31.500 l/h 30.900 l/h 20,00 30.300 l/h
B70 11/2" 3 4.440 l/h 4.320 l/h 3,00 4.200 l/h B550 3" 15 33.900 l/h 33.600 l/h 20,00 32.700 l/h
B100 2" 3 7.200 l/h 6.900 l/h 4,00 6.300 l/h B600 3" 15 37.800 l/h 37.200 l/h 20,00 36.000 l/h
B150 2" 4 10.200 l/h 9.840 l/h 5,50 9.360 l/h
PUMPMOTOR SIZE
GR HP A B C D E F G H I L M N O Ø Kg.
A
MBM 5 71 C4 0.35 9 300 400 70 240 200 136 257 90 140 398 13 59 1/2” 19
MBM 1071 C4 0.35
19 300 400 70 240 200 136 257 90 140 405 13 69 3/4”19.5
71 S4 0.5 20
MBM 1571 S4 0.5
14 300 400 70 240 200 136257
92140 418
13 64 3/4”20
80 C4 0.75 274 157 453 21
MBM 2580 C4 0.75
22 300 400 70 240 200 136 274 92 157 461 13 72 3/4”21.5
80 S4 1 23
MBM 4080 S4 1
35 400 500 70 240 200 146289
119157 508
13 85 1”26
90 C4 1.5 292 180 536 28
B
MBM 5090 C4 1.5
39 400 500 70 240 200 161 310 100 180536
13 89 1” 1/236
90 S4 2 561 39
MBM 7090 L4 2.5
50 500 600 70 290 250 182310
100180 571
13 100 1” 1/241
100 C4 3 320 200 611 43
MBM 100100 C4 3
50 500 600 70 290 250 182 349 136 200 631 13 100 2”51
100 S4 4 54
MBM 150100 S4 4
70 500 600 70 290 250 176349
136200 651
13 120 2”57
112 S4 5.5 361 224 671 74
C
MBM 200112 S4 5.5
127550 650
70340 300
176357
212224 709
13 177 2” 1/275
132 S4 7.5 700 800 400 360 382 189 761 84
MBM 250112 S4 5.5
139550 650
70340 300
176357
212224 721
13 189 2” 1/276
132 A4 10 700 800 400 360 382 189 811 80
MBM 300132 S4 7.5
151 700 800 70 400 360 176 382 212 189785
13 201 2” 1/292
132 A4 10 823 100
MBM 350132 S4 7.5
163 700 800 70 400 360176 382
212189 797
13 213 2” 1/293
160 C4 15 197 434 336 947 130
MBM 400132 A4 10
177700 800
70 400 360176 382
212189 849
13 227 2” 1/2107
160 C4 15 900 1.000 197 434 336 961 138
MBM 450132 A4 10
174 900 1.000 70 400 360 212433
263189 849
13 224 3”132
160 C4 15 464 336 961 160
MBM 500160 C4 15
183 900 1.000 70 400 360 212 464 263 336970
13 233 3”167
160 S4 20 1.014 200
MBM 550160 C4 15
192 900 1.000 70 400 360 212 464 263 336979
13 242 3”173
160 S4 20 1.023 204
MBM 600160 C4 15
201 900 1.000 70 400 360 212 464 263 336988
13 251 3”178
160 S4 20 1.032 208
30 31
RL METHANOL TRANSFERRING UNITS
TYPE RL 140 ZW RL 260 ZW
MAX. FLOW l/h 140 260
FEEDING FLOW l/h 70 130
UNIT CONNECTIONS
SUCTION 1/2” 1/2”
DRIVE 1/2” 1/2”
OVERPRESSURE 1/2” 1/2”
SUPPLY VOLTAGE VOLT 400 tri-phase 400 tri-phase
MOTOR POWERKW 0,25 0,37
C.V. 1/3 1/2
OVERPRESSURE VALVE OPENS AT:
bar 6,5 6,5
DIMENSIONS mm 800 x 800 x 300 800 x 800 x 300
WEIGHT kg 65 74
1. Suction pipe2. Filter3. Vacuum gauge4. Pressure switch-low presure security5. Triphase motors6. Magnetic coupling7. Gear pump8. Anti return valve9. Pressure gauge10. Overpressure control valve11. Overflow pipe12. Pressure pipe
Technical data electrical-control cabinet
DIMENSIONS mm 400 x 400 x 200 mm
WEIGHT kg 10
PROTECTION RATE IP 55
AUTOMATIC ALTERNATING SWITCH With internal timer
Ø FOR CABLE GLAND mm 20
�
�
�
�
� � � � �� �� �� ��
����������������������������������
�����������
�����
���������
�����
�������������
32
OIL TRANSFER PRESSURE UNITSGP-30 NW / GP-30 NW ECI MOTOR
* United States Patent Nr. 5,318,437
Delivery pressure 2 bar / 2 kg/cm2
Suct
ion
in m
. (m
anom
etric
hei
ght)
kinematic viscosity= ү37 ~4 c St.density= √15~0,841 kg/l
Light Oil In meters (length + elevation)
UNUSABLE ZONE
MODELGP30 NGP30 GE
GP30 N ECI-IP54GP30 GE ECI-1P54
FLOW l/h 30 30
CONNECTION TO THE HYDRAULIC CIRCUIT(Ø THREAD / Ø mm)
SUCTION 10 10
DRIVE 3/8” F 3/8” F
POWER SUPPLY VOLTS 230 single-phase 230 single-phase
CONSUMPTION AMPS 1,38 1,38
MOTOR POWER C.V. 1/6 1/6
MAX. PRESSURE kg/cm2 3,5 3,5
SAFETY VALVE OPENS AT: kg/cm2 4 4
SOUND LEVEL dB (A) 58 58
MOTOR PROTECTION IP IP-20 IP-54
DIMENSIONS (mm) W x H x D240 x 330 x 205800 x 460 x 250
240 x 330 x 205800 x 460 x 250
APPROX. WEIGHT Kg.6,421
6,421
GREEN TECH
32 33
OIL SUCTION TRANSFER UNIT GPS-10
PUMP TYPE Suction Solenoid Pump
LIFTING HEIGHT (MAX.) 8 m. vertical (8 mm I.D. tube)
MÁX. HORIZONTAL DISTANCE 100 m. horizontal (8 mm I.D.. tube)
OUTLET FLOW RATING (8 MM I.D. TUBE)8 l/hr at: 8 m vertical & 25 m horizontal15 l/hr at: 5 m vertical & 25 m horizontal
INLET CONNECTION 3/8“ F BSP
OUTLET CONNECTION 3/8“ F BSP
OVERFLOW OUTLET CONNECTION 1/2“ F BSP
POWER SUPPLY AC 230V, 50Hz
POWER CONSUMPTION 50 W
RESERVOIR TOTAL CAPACITY 3,5 Litre
DIMENSIONS (W X D X H) 240 x 125 x 300 mm
WEIGHT 3 kg
FUEL TYPE Kerosene & Diesel Oil
Optional Fittings Product code
- Double line filter with deaerator for burner return 01110006003807- Oil collecting tray with infrared Leak Detector for GPS10 23090000001035- Oil collecting tray with infrared Leak Detector for GPS10 MAXI 23090000002035
34
MICRO DOMESTIC
TECHNICAL SPECIFICATIONS:
- Domestic oil lift pump, designed to supply diesel or kerosene to small heating appliances when a higher than normal lift is required -for example oil tank situated up to 15 metres lower than the burner-, and do not require more than17 l/h oil.
- The MICRODOMESTIC is electrically connected to the burner, and comes into operation only when the appliance requires oil.
Capacity
- The MICRODOMESTIC oil lift pump is designed to assist in the burner automatic supply of diesel. - This little pump, can suck oil up to 3 meters in vertical or 25 mt. horizontal and drive up the oil up to 15 meters in vertical (1.5 kg/cm2)
Warranty
- To ensure proper operation, each unit must pass 24 hours running at the test bench, prior to dispatching. - Supplied with glued flexible tubes and fittings for 10 mm. O.D tube for the easier hydraulic connection. Screws and plastic lugs are also provided for easier fixing to the wall.
- The stainless steel cover protects it from shocks and provide a design adapted to a domestic environment. - INPRO MICRODOMESTIC is a quality product, with full operation warranty, easy to install and extremely silent.
MAX. FLOW RATE 17 lts/h
MAX. SUCTION HEIGHT 3 m.
MAX. DRIVE PRESSURE 15 m. (1,5 kg/cm2)
POWER SUPPLY 230 V 50 Hz
POWER CONSUMPTION 18 W
INLET AND OUTLET CONNECTION 8 mm.
1. Main tank2. Level gauge probe3. Floating suction4. Ventilation Tee5. Manhole6. Intake pipe7. Filter8. Solenoid pump9. Burner
34 35
PRESSURE SWITCHES FOR OIL AND WATER
OIL FILTERS
MODELPRESSURE
CONNECTIONMinimum Maximum Security cut off
DSSG-1 with pilot 1,5 4,5 0,8 Tube 10
DSSG-1 without pilot 1,5 4,5 0,8 Tube 10
DSSG-2 with pilot 3,7 7 0,8 Tube 10
DS-1A attached 1,5 4,5 - 1/4 male
SS-1A 1,2 4,5 - 1/4 female
SS-1A inverter 0,3 - - 1/4 female
MODEL FLOW (l/h) CONNECTION FILTRATION
BASK
ET
450/3 plastic 40 3/8” 0,1
450/2 aluminium 40 3/8” 0,1
302 plastic 80 1/2” 0,1
301 aluminium 80 1/2” 0,1
313 aluminium 150 1/2” 0,1
207 aluminium 200/400 3/4” 0,1
101 aluminium 400/1.000 1” 0,1
503 aluminium 4.000/15.000 1 1/2” 0,1
SELF
-CLE
ANIN
G
112 300 1/2” x 1/2” 0,1
112 300 1/2” x 1/2” 0,3
213 1.000 1” x 1/2” x 1” 0,1
213 1.000 1” x 1/2” x 1” 0,3
313 2.000 1” x 1/2” x 1” 0,1
313 2.000 1” x 1/2” x 1” 0,3
410 5.000 11/2” x 11/2” 0,1
410 5.000 11/2” x 11/2” 0,3
MODEL SIZE FILTRATION
WIT
H RE
SIST
ANCE
70º
C Basket 157 1/2” 0,3
Basket 151 1” 0,3
Basket 503 11/2” 0,3
Self-cleaning 112RE 1/2” 0,3
Self-cleaning 313RE 1” 0,3
Self-cleaning 410B 1 1/2” 0,3
BIOD
IESE
L 451 3/8” 0,1
312 1/2” 0,1
101 1” 0,1
503 1 1/2” 0,1
Water separating filters- Gasoline-water sep. filter 1” Q= 105 l/min - Gas-oil-water sep. filter 1” Q= 105 l/min - Filtering paper refill 5 microns Q= 105 l/min - Water separating filter 1 1/2” Q= 210 l/min - Filtering papel refill 5 microns Q= 210 l/min
70°C
36
The Inpro leak detector detects the presence of liquids through its infra-red sensor, activating or deactivating the desired device.
The relay output can activate or deactivate any device; for instance, a siren or a bigger light-giving indicator.
This outlay makes possible to have one device (or several) in normal ope-ration condition, and another device (or several) coming into operation when it is activated (wiring diagram).
Plug version
*Certificate BPG 09/5211 ÜS under WHG norm, part § 19h (Water Resources Act) by TUV-Nord is available.
LEAK DETECTOR
MODEL POWER SUPPLY
Maximum consumption
MAXIMUM RELAY
INTENSITY
VOLTAGE FREE RELAY
VISUAL ALARM(red 5-mm LED)
VIEW ON(green 5-mm
LED)Art. Nr.
Plug Version
230 V a.c.
120 mA 10 A NO YES YES 23080000001111
Wall MontingVersion
230 V a.c.
120 mA 10 A YES YES YES
23080000000111
23080000000111 (UK)
Wiring Diagram (Wall Mounting Version)
GREEN RED
IPD
-003
0
LEA
KM
OD
ULE
JP1
IPD
-003
4-C
R
+
BUZZER
GR
OU
ND
GR
OU
ND
NC
NC
CO
MN
ON
C
55
43
12
INPRO S.L.IPD - 0000 - E
LEA
KM
OD
ULE
IPD
-003
0
Probe 1
Probe 2 (optional)
Power supplyconnector
Relay Output connector
Serial Nr.
Ground connection
Connections:
5 – Neutral5 – Neutral4 – Live
3 – Relay common1 – Relay normally closed NC2 – Relay normally open NO.
GROUND: Faston connector terminal size M3,5.
Visuals Alarms:
Green: System OK. No Alarm
Red: Alarm and Relay active
OIL COLLECTING TRAYS
- For other sizes please consult.
Metal, Eproxy painted RAL 7032, with fixing clip for infrarred leak detector.
MODÈLE DIMENSIONS mm GROUPS Code
40 400 x 230 x 60 GP-30 N 21030000004000
62 620 x 230 x 60 GP-30 GE ; GP-70 N ; GP-130 N ; GP-200 N ; GP-300 N ; GP-500 N 21030000006200
92 920 x 350 x 60 GP-70 GE ; GP-130 GE ; GP-200 GE ; GP-300 GE ; GP-500 GE 21030000009200
120 1200 x 350 x 60 21030000001200
36 37
Compact set for burner gas-oil inlet mounted on aluminium manifold. Endowed with all elements necessary for inlet and return to gas-oil burner.
HOW IT IS APPLIED
1. Main storage tank2. Intake pipe 3. Over�ll prevention kit4. Remote level gauge EDM 405. Pressure Pump Inpro GP6. Filter7. Pressure reduction valve (using pressure gauge)8. Air vent9. Modulating burner12. Reservoir13. Membrane expansion vessel14. System draining
PRESSURE REDUCING VALVES
FLOW l/h
MAXIMUM INLET PRESSURE REGULATION CONNECTION ACCESSORIES
15 6 bar Adjustable 0,2-3,5 kg/cm2 For 8 mm tube Locked box, filter and quick shutoff valve
20 10 bar Fixed outlet 0,1 kg/cm2 For 8 mm tube
20 10 bar Fixed outlet 0,1 kg/cm2 For 10 mm tube
200 10 bar Adjustable 0,2-3,5 kg/cm2 Female 1/4” With manometer
500 10 bar Adjustable 0,2-3,5 kg/cm2 Female 3/8” With manometer
1.500 25 bar Adjustable 0,2-3,5 kg/cm2 Female 1/2” With manometer
2.000 25 bar Adjustable 0,2-3,5 kg/cm2 Female 3/4” With manometer
3.000 25 bar Adjustable 0,2-3,5 kg/cm2 Female 1” With manometer
INPRO OIL BURNER INLET ASSEMBLY
Content:INPRO-OIL BURNER
INLET assemblyINPRO-OIL BURNER INLET STABILIZER assembly,
for Modulating Burners
20 litre/hour 200 litre/hour 200 litre/hour 500 litre/hour 1.500 litre/hour
Filter 0,1 mm 3/8” 0,1 mm 1/2’’ 0,1 mm 1/2’’ 0,1 mm 3/4’’ 0,1 mm 1’’
Pressure reducing valve 20 l/h adjustable with manometer 200 l/h adjustable with manometer200 l/h adjustable with manometer
500 l/h adjustable with manometer
1500 l/h adjustable with manometer
Burner intake 10 mm 1/2” 3/4” 3/4” 1”
Burner return 3/8” 1/2” 3/4” 3/4” 1”
Circulation and accumulation reservoir
- - 50 litres 50 litres 50 litres
Expansion vessel for heating oil
- - 5 litres 5 litres 5 litres
Emptying connection - - 1/2” 1/2” 1/2”
Air vent - - 3/8” 3/8” 3/8”
Max. work pressure 4 bar 4 bar 4 bar 4 bar 4 bar
Max inlet pressure 6 bar 6 bar 6 bar 6 bar 6 bar
Vertical / horizontal attachment support
NO YES NO NO NO
Art. Nr. 23010000000102 23010000000120 23010000001120 23010000001150 23010000001215
38
Directly controlled, spring-loaded overflow valve to maintain a set operating pressure or a set maximum pressure.
For lubricating and hydraulic oils and many other self-lubricating, non-corrosive fluids.
Maximum temperature of delivery fluid: 250 °C.Material: Casing of hydraulic cast iron. Piston, valve tip, spring made of hardened steel.
1) Performance curve to be considered
XT
PP
T
XP
T X
X P
T
P
TX
X
X
X P
T
T- Tank (Overflow)X- Closed or Pressure GaugeP- Pressure
D
B A C
�� ��������������������������� ��
�� ��������������������������� ��
�� ������������������������ ��
� ����������������������� ��
����������
� �� �� ����� �� �� �� �� ��� ��� ��� ��� ��� ��� ���
�
�
�
�
�
�
�
�
�
��
����������
� ��� ����� �������� ��� ��� ��� ����� ����� ����� ����� ����� ����� ����� �����
�
�
�
�
�
�
�
�
�
��
��������
� ����� ����� ����������� ����� ����� ����� ����� ����� ����� ����� ������ ������ ������
�
�
�
�
�
�
�
�
������
��
�
����������
� �� ��� ����� ��� ��� ��� ��� ��� ��� ��� ��� ��� ��� ���
�
�
�
�
�
�
�
�
�
��
OVERFLOW VALVES
MODELPRESSURE RATING
FOR TYPE (Order No.)
CONNECTION THREAD/FLANGE
FLOW RATE1)
l/h
VISCOSITY RANGE1)
cSt
DIMENSIONS
Art. Nr.
A B C D
2
0= 0,5 - 1,5 bar1= 1 - 4 bar2= 2 - 9 bar
3= 6 - 26 bar4= 15 - 40 bar
G 1/4” 15 - 120 2,8 - 480 44 36 34 26 -
3 G 3/8” 24 - 160 2,8 - 480 55 51 37 36 06080001301038
5 G 1/2” 90 - 600 2,8 - 480 55 51 37 36 06080001601012
6 G 3/4” 300 - 2000 2,8 - 480 63 50 60 73 06080002201034
7 G 1” 900 - 6000 2,8 - 480 80 48 58 86 06080002601100
8 G 1 1/4” 1500 - 10000 2,8 - 480 80 71 60 56 -
90= 0,5 - 1,5 bar
1= 1 - 4 bar2= 2 - 9 bar
3= 6 - 25 bar4= 15 - 40 bar
DN 15 90 -600 2,8 - 480 92 55 95 92 06080001601915
10 DN 20 300 - 2000 2,8 - 480 118 63 106 118 06080002201920
11 DN 25 900 - 6000 2,8 - 480 134 80 115 134 06080002601925
12 DN 32 1500 - 10000 2,8 - 480 138 80 140 138 06080003101932
38 39
SOLENOID VALVE N/C FOR OIL 1 x 230 V NORMALLY CLOSED NORMALLY OPEN
Solenoid valve for oil N/C 3/8” 23030000000389 23030000010389
Solenoid valve for oil N/C 1/2” 23030000000129 23030000010129
Solenoid valve for oil N/C 3/4” 23030000000349 23030000010349
Solenoid valve for oil N/C 1” 23030000001009 23030000011009
Solenoid valve for oil N/C 1¼” 23030000001149 23030000011149
Solenoid valve for oil N/C 1½” 23030000001129 23030000011129
Solenoid valve for oil N/C 2” 23030000012009
Solenoid valve for oil N/C 2½” 23030000012129
Solenoid valve for oil N/C 3” 23030000013009
SOLENOID VALVE FOR HEATING OIL, WITH FILTER AND FLOW LIMITER CODE
Solenoid valve for oil N/C 3/8” 23030000050389
Solenoid valve for oil N/C 1/2” 23030000050129
Solenoid valve for oil N/C 3/4” 23030000050349
Solenoid valve for oil N/C 1” 23030000051009
Solenoid valve for oil N/C 1¼” 23030000051149
Solenoid valve for oil N/C 1½” 23030000051129
Solenoid valve for oil N/C 2” 23030000052009
CONNECTIONMECHANICAL AUTOMATIC
CODE CODE
1/2” 23040000000012 23040000001012
3/4” 23040000000034 23040000003034
1” 23040000000100 23040000001100
1½” 23040000000112 23040000001112
MANUAL AND AUTOMATIC SWITCHOVER MANIFOLDS FOR 2 STORAGE TANKS
1. Oil tank2. Suction3. Flexible probe for EDM-40 2”4. Fill cabinet for 2 tanks and EDM-405. Oil collecting tray with infrared6. Inpro GP7. Automatic switchover manifolds
OIL INSTALLATION EQUIPMENT - SOLENOID VALVES - AUTOMATIC MANIFOLDS
40
SAFETY + OVERFILL CONTROL SYSTEM FOR DAILY TANKS
SAFETY + OVERFILL CONTROL SYSTEM FOR DAILY TANKS CODE
Safety + overfill control system 3/8” 23030000060389
Safety + overfill control system 1/2” 23030000060129
Safety + overfill control system 3/4” 23030000060349
Safety + overfill control system 1” 23030000061009
Safety + overfill control system 1¼” 23030000061149
Safety + overfill control system 1½” 23030000061129
G.E.
1
2
4
59
1213
11.1 11.2
10
15
63
8
14.1 14.2
16
7
FLOW SAFETY SWITCH AT TANK VENT FOR OVERFILL PREVENTION
SMMR-FL 1 CODE
Probe monted at steel “T” 11/2” stainless steel. Ø 28 mm + control unit 1 relay 21150000011200
1. Main storage tank2. Suction3. EDM40 level gauge flexible probe4. EDM40 control display with 2 relay output5. Overfill warning kit with alarm and reset6. Liquid barrier7. DDP25 leak detection system for double skinned tanks8. INPRO GP Pumpset for oil9. NC solenoid valve for oil with flow limiter10. SMMR-2 level control11.1. Level probe Open/Close/Safety stop11.2. Level probe NO solenoid v. (Very high level)12. Filter13. NO Solenoid valve for oil14.1 Flow switch control at vent (probe)14.2 Flow switch control at vent (control)15. Power Generator16. Leak detection system, wall mounting system
From 9 to 13: CONTROL AND OVERFILL SECURITY SYSTEMFrom 14.1 and 14.2 : CONTROL AND OVERFILL SECURITY SYSTEM
40 41
TANKALERT ECO OILEconomy and Ecology
TANKMin. 0,5 m (depth) - Max 3 m (depth or wide)Max 19.999 litres - Min 300 litres (content)
MEASUREMENTDISPLAY
Multi-function LCD display including: - 10 bar-graph level indication on both Inpro EcoOil Monitor and Transmitter* - Display of various current and historical values - Display control with five control buttons. - Red LED for low level indication at 5% or less of usable fuel remaining. - Audible alarm sounds every hour on the hour when the tank level is low.
* The transmitter and Monitor bar-graph displays may differ (see display symbol reference table).
MAX COMUNICATIONDISTANCE
Typically 150m in normal ‘line of sight’ conditions
POWER SUPPLY
Receiver: - Mains Power Supply (included): 150V-240V, 50-60 Hz, meets EN60950-1. (5V DC (40mA)) - Back up battery**: 3V LiMn
** This device contains a small battery to keep time during power cuts. If the device is left unpowered for an extended period then the battery will deplete.
BATTERY LIFE Transmitter: 5 years (estimated life)
WIRELESS COM 433MHz FM transmission (EN300-220)
DIMENSIONSReceiver: 120mm x 90mm x 50mmTransmitter: 140m x 70mm x 40mm
MAX AND MIN OPERATION (TRANSMITTER)
Operating temperature range: -10°C to +60°COperating Humidity : 0 -95% non-condensing
HOLE SIZE FOR TANK FITTING
60 mm or 2”, 1½”, 1¼”, thread
Warranty 2 years
1
7
65432
8
HH
Type A
H
W
HW
Type B
WH WH
Type C
ONLY 4 STEPS… AND READY TO USE: 1. Eco Oil display setup (time, tank type, litre volume and size:-W&H-).
2. Connect the monitor at a plug and pair with sender.
3. Install the transmitter on the tank thread or hole (2“, 1 ½“, 1 ¼“ or 60 mm)
4. Eco Oil will display: • Remaining volume in litres and % oil. • Days to empty. • Oil average cost per day, week, month or year. • Environmental: kgCO2 emitted per day, week, month or year.
SOLUTION FOR RESERVOIRS WITH OBSTACLES:
Waveguide Mode Operation:Tankalert EcoOil can be mounted and programmed at installation site with a 32 mm OD tubing (not included). This avoids any ultrasonic read error in the case of an obstacle is the inner tank (suction pipe, not regular tank walls, etc ...) avoids the correct ultrasonic function, as the reading is done inside this tube.
- Tankalert EcoOil PlusIt allows to remote monitoring the volume at underground tanks, or with FM communication difficulties with the receiver.
1. LCD Display2. MODE key3. DOWN key ()
4. Enter key5. UP KEY ()
6. SETUP key7. Alarm Red LED8. Tank top Transmitter oil level display
42
– The SMMR level switches are custom-built to each customer’s particular needs, allowing automated control of the filling and emptying of one or more tanks.
– This system work with fluids such as gasoline, oil, water, milk, etc.
– This panel controls can activate or control pumps, electrovalves, optical and acoustic alarms.
– Models: - SMMR1:Operations of safety maximum and minimum. - SMMR2: With two voltage-free relays - SMMR3: With three voltage-free relays
APPLICATIONS / EXAMPLES
���
���
Filling of a tank by means of the level switch
As the liquid level drops to the minimum level, the electrovalve opens, triggering the in activation of the pressure system, which fills the tank until the liquid level reaches the maximun level, which then closes the electrovalve.
�
�
�
��� � � � � � � � �
�
Remote control of various locations of the tank
When the tanks level increases or decreases, the microswitches begin closing successively, sending signals to the controller to make the appropriate adjustments.
VERSIONS Art. Nr.
• SMMR 1: Low, high and very high 23060000010010
• SMMR 2: With 2 voltage-free relays 23060000020010
• SMMR 3: With 2 voltage-free relays 23060000030010
• SMMR Flexible probe 230600000-1211
• SMMR 4 points + reserve 23060000300001
LEVEL SWITCH SMMR
42 43
2 Measuring possibilities to choose
2 How it is applied:
% (1, 2.., 100 %) Litres
EDM-40 REMOTE LEVEL GAUGE AND CONTROL
EDM-40 Remote level gauge - Continuous measure
- Shows on his display the content of a tank in liters or percentage. Valid for almost any oil, liquid or fluid. Till 125ºC.- It can be completely configured depending on the installation needs.- The installation is extremely simple, because all settings are adjusted from manufacturing.- His expansion slots adapts it to each installation needs.- Standard housing (DIN 43700) 96 x 43 x 100 ready for panel built-in mounting.- Flexible probe available in, 1”, 11/2” and 2” thread adapters.
EDM-40: Components and versions Art. Nr.
- EDM-40 control box, 230 V AC. 23050020409000- EDM-40 control box, 24 V DC. 02050000000290- Polyethylene flexible probe. 23050010402590- Stainless Steel AISI-316 Inox Probe. 23050010402090- 1 relay Module. 02050000000010- 2 relay Module. 02050000000020- 4 relay Module. 02050000000040- Analog Output Module 0-10 V / 4-20 mA. 02050000000100- GSM analog signal transmitter to mobile telephone. 28000000000000- GSM mini digital 1 alarm transmitter to mobile telephone. 22050010000194
44
Wiring diagram for overfill control system kit
Wiring diagram for analog and relay connections
Technical Specifications
DISPLAY AND CONTROL UNIT PROBE
Protection Rate: IP 67 Aluminium isolating head: 2”
Power consumption (display + probe) <30 Va. Isolation rate: IP 65
Standard Electric supply: 230/115 Vac Other optional connecting thread: 1”, 11/4” and 11/2”
Optional versions: 48/24 Vcc - 18/48 Vcc Standard probe: flexible (Nylon)
Temperature range of function: 0º a 50ºC Max temperature in flexible standard probe: 40ºC
Electromagnetic compatibility: EN 61000-6-2, EN 61000-6-3
Optional Inox (rigid): stainless steel AISI-316
Security Norms: EN 61010-1 Max temperature with stainless steel Probe: 125ºC
Material: PC-ABS
Measures (mm): 96 x 43 x 100 (DIN 43700)
Certifications: CE, UR, CSA
This manufacture definition is subject to change accordingly to specific installation needs.
44 45
GAS DETECTION UNIT GLP-813 WITH PROBE
The GLP 813 gas detection unit performs in accordance with the current regulations for the presence of gas.
When gas is detected, the GLP 813 activates the electrovalve, cutting off the gas into the boiler room and set off the alarm or activates an extractor to renew the atmosphere in the room.
CHARACTERISTICS
– Automatic detectors with control sensors respond to ambient conditions in each of the boiler rooms.
– Detects the presence of gas to levels of 25% of the minimum level required for an explosion. Each GLP-813 detector can work with one or two remote detection probes fed with 5 volts.
– GLP 813 units are available which can work at high temperatures are avatable. Erected on a stand and in a metal box which is heat and dent resistant.
– Available to be set up on a DIN holder version
– The GLP-813 can be supplied with a version manual reset switch built into the system.
– To facilitate installation, each unit is provided with 10 meters of cable.
– Applicable to natural gas, residential heating gas (for other gases please consult) ,butane, propane and methane.
- Propane, butane: Probes placed 30 cm max from the room floor. - Natural gas, city gas (lighter gases) : 30 cm from the room ceiling.
������
��������������������
��
������
��
�
����
����
����������
������� �������
�������� ������ ������������ ��������������
�����
������������� ���������������������������
GLP-813 Gas Detector, version with automatic reset switch
To operate on EV magnet valve model (N/C), install according to the diagram below. When working with other voltages (12-24 V, etc.) use strips 3, 4 and 5. Voltage-free relay connection.
������
��������������������
��
������
��
�
����
����
����������
������� �������
�����
������������ ��������������������������������������������������
GLP-813 Gas Detector, version with reset switch
To operate on VMR (N/C) , install according to the diagram below. When working with other voltages (12-24 V, etc.) use strips 3, 4 and 5. Voltage-free relay connection.
46
FUEL OIL METERS CONTOIL® VZO 4 AND 8
WITHOUT PULSEREED OUTPUT
WITH PULSEREED OUTPUT
Art. Nr. Art. Nr.
VZO-4 Q 0,5 92678
VZO-4 92680 89761
VZO-8 92630 89731
Type VZO-4 Qmin 0,5 VZO-4 VZO-8
Nominal diameter mminch
41/8
41/8
81/4
Connection threads of meter inch 1/8 1/8 1/4
Nominal pressure bar 25
Temperature Tmax ºC 60
Maximum flow rateDébit permanentMinimal flow rateApprox. starting flow rate
Qmax1)
Qnom1)
Qmin2)
l/hl/hl/hl/h
40250,50,3
80501
0,4
200135
41,6
Max. permissible errorRepeatability
± 1 % of actual value2)
± 0,2 %
Smallest readable amountRegistration capacity
lm3
0,001100
0,001100
0,011000
Safety filter mesh sizeDirt filter mesh size
mmmm
0,1250,080
0,1250,080
0,1500,100
Volume of the measuring chamber approx. cm3 5 5 12,5
Weight without couplings approx. kg 0,65 0,65 0,75
Reed pulsers RE 1RE 0,1
l/ pulse --
-0,1
1-
1) For burners and engines or motors, the meter must be selected on the basis of the permanent flow rate. For higher viscosities, or if the meter is installed on the suction side, the pressure drop and any reduction in the measuring range must also be taken into consideration.2) Max. permissible error: VZO 4 Qmin 0.5: 0.5 l/h...2 l/h = +1 %/–2 %. VZO 4: 1 l/h...2 l/h = +1 %/–2 %.
Dimensions en mm
VZO/VZOA 4 and 8
DN 4
19
Rp 1/8
DN 8
11,5
23
1832
Rp 1/4
without pulser
73
5,5
68
with pulser
55
34
13,5
(VZO
4) / 1
4,5 (V
ZO 8)
79
63
46 47
FUEL OIL METERS CONTOIL® VZO 4 AND 8 OEM
Art. Nr.
VZO-4 OEM 89765
VZO-8 OEM 89771
Type VZO-4 OEM VZO-8 OEM
Nominal diameter DN mminch
41/8
81/4
Connection threads of meter inch 1/8 1/4
Nominal pressure bar 32 25
Temperature Tmax ºC 60 60
Maximum flow rateNominal flow rateMinimal flow rateApprox. starting flow rate
Qmax1)
Qnom1)
Qmin2)
l/hl/hl/hl/h
80501
0,4
200135
41,6
Max. permissible errorRepeatability
± 1 % of actual value2)
± 0,2 %
Safety filter mesh sizeDirt filter mesh size
mmmm
-0,080
0,1500,100
Volume of the measuring chamber approx. cm3 5 12,5
Weight approx. kg 0,65 0,75
Reed pulsers RE l/pulse 0,005 0,0125
Pulse frequency at Qmaxat Qmax
HzHz
4.4440,056
4.4440,089
1) For burners and engines or motors, the meter must be selected on the basis of the permanent flow rate. For higher viscosities, or if the meter is installed on the suction side, the pressure drop and
any reduction in the measuring range must also be taken into consideration.2) Max. permissible error: VZO 4 OEM: 1 l/h...2 l/h = +1 %/–2 %.
- Remote display of flow metering - Remote display of time of burner operation- Battery life ± 5 years
REMOTE TOTALIZER FLOW / TIME Art. Nr.
Flow-Time remote totalizer 25000000000021
- Power supply: 230 V, 50/60 Hz - Registration capacity: 10.000 l - Pulse value (input): 0,005 l
- Panel cut-out: 27 x 14,4 - 0/+0,2 mm - Smallest readable amount: 0,005 l - Installation depth: 56 mm
REMOTE TOTALIZER FOR VZO-4 OEM Art. Nr.
Remote totalizer VZO-4 OEM 25000000000021
- Remote display of flow metering- Reset pushbutton - Battery life ± 5 years
REMOTE TOTALIZER WITH RESET FOR VZO RE Art. Nr.
VZO RE Totalizer 25000000000021
48
FUEL OIL METERS CONTOIL® VZO 15...50
WITHOUT PULSE REED OUTPUT WITH PULSE REED OUTPUT
Art. Nr. Art. Nr.
VZO-15 92041 92042
VZO-20 92047 92048
VZO-25 92057 92058
VZO-40 92004 92018
VZO-50 92007 92024
Type VZO 15 VZO 20 VZO 25 VZO 40 VZO 50
Nominal diameter DN (mm)inch 3/4” 1” 1 1/4” 1 1/2”
50
Installation length mm 165 165 190 300 350
Nominal pressure with threaded ends with flanges
PNPN
barbar
1625,40
Maximum temperature Tmax ºC 130, 180
Maximum flow rateNominal flow rateMinimal flow rateApprox. starting flow rate
Qmax1)
Qnom1)
Qmin
l/hl/hl/hl/h
600400104)
4
15001000
3012
30002000
7530
9000600022590
30.00020.000
750300
Max. permissible errorRepeatability
± 1 % of actual value± 0,2 %
Safety filter mesh size Dirt filter mesh size
mmmm
0,4000,250
0,4000,400
0,4000,400
0,8000,600
0,8000,600
Volume of the measuring chamber approx. cm3 12 36 100 330 1200
Housing finish enamelled red RAL 3013
Weight with threaded ends 2)
with flanges PN 25 with flanges PN 40
approx. kgapprox. kgapprox. kg
2,23,84,4
2,54,55,5
4,27,57,8
17,320,320,5
-41,042,0
Smallest readable amountRegistration capacity
lm3
0,011000
0,110.000
0,110.000
0,110.000
1100.000
Pulse values of pulsers:IN inductive according to IEC 60947-5-6RV ReedRV Reed
l/pulsel/pulsel/pulse
0,010,11
0,011-
0,11-
0,11-
110
100
Pulse frequency IN at Qmaxat Qmax
HzHz
16.6670,278
41.6670,833
8.3330,208
25.0000,625
8.3330,208
3) For burners and engines or motors, the meter must be selected on the basis of the permanent flow rate. For higher viscosities, or if the meter is installed on the suction side, the pressure drop and any reduction in the measuring range must also be taken into consideration.4) Min. flow rate VZO 15 with IN-pulser: 15 l/h5) Weight without couplings.
Dimensions in mm
Flow sensors (all types)DN 15, 20, 25: with threaded ends (ISO 228-1) DN 40: with threaded ends (ISO 228-1)
DN 15, 20, 25: with flanges (DIN 2501/SN 21843) DN 40, 50: with flanges (DIN 2501/SN 21843)
h1h2
B L
ØF
b h1h2
H
66212B AM066160.4B
48 49
FUEL OIL METERS CONTOIL® VZF 15...50
Art. Nr.
VZF-15 93705
VZF-20 93708
VZF-25 93725
VZF-40 93730
VZF-50 93735
Type VZF 15 VZF 20 VZF 25 VZF 40 VZF 50
Nominal diameter DNinch 3/4” 1” 1 1/4” 1 1/2”
50
Installation length mm 165 165 190 300 350
Nominal pressure with threaded ends with flanges
PNPN
barbar
1625
1625
1625
1625
1625
Maximum temperature Tmax ºC 130, 180
Maximum flow rateNominal flow rateMinimal flow rateApprox. starting flow rate
Qmax1)
Qnom1)
Qmin
l/hl/hl/hl/h
600400102)
4
1.5001.000
3012
3.0002.000
7530
9.0006.00022590
30.00020.000
750300
Max. permissible errorRepeatability
± 1 % of actual value± 0,2 %
Safety filter mesh sizeDirt filter mesh size
mmmm
0,4000,250
0,4000,400
0,4000,400
0,8000,600
0,8000,600
Volume of measuring chamber approx. cm3 12 36 100 330 1200
Housing finish enamelled red RAL 3013
Weight with threaded ends2)
with flanges PN 25approx. kgapprox. kg
2,23,8
2,54,5
4,27,5
17,320,3
-41,0
Smallest readable amount:Total volumeResettable volumeDigital flow rate displayRegistration capacity
l, m3
l, m3
l/hl, m3
No decimal places1 decimal place 1 decimal place
8 digits
Outputs3)
Pulse value for totalisorCurrent 4..20 mA for flowrateFrequency for flowLimiting switch
Vol./pulse.l4/Q1, I20 Q2f1/Q1, f2/Q2Qmin, Qmax
pulse value and width parameterisableflow rates to 4 and 20 mA parameterisable
frequency and flowrate parameterisableminimum, maximum and hysteresis parameterisable
3) For burners and engines or motors, the meter must be selected on the basis of the permanent flow rate. For higher viscosities, or if the meter is installed on the suction side, the pressure drop and any reduction in the measuring range must be taken into consideration.4) Weight without couplings.5) Two freely selectable outputs are available, totally independent of each other.
Dimensions in mm
Flow sensors (all types)DN 15, 20, 25: with threaded ends (ISO 228-1) DN 40: with threaded ends (ISO 228-1)
DN 15, 20, 25: with flanges (DIN 2501/SN 21843) DN 40, 50: with flanges (DIN 2501/SN 21843)
h1h2
B L
ØF
b h1h2
H
66212B AM066160.4B
50
GP O
IL S
UPPL
Y TO
2 B
URNE
RS
1. M
ain
stor
age
tank
2. E
DM-4
0 Re
mot
e le
vel g
auge
pro
be3.
Flo
atin
g su
ctio
n4.
EDM
-40
Rem
ote
leve
l gau
ge s
cree
n5.
Ove
rfill
prev
entio
n ki
t6.
Inta
ke p
ipe
7. F
ilter
8. V
acuu
m g
auge
9. Q
uick
shu
toff
valv
e10
. Ele
ctric
gea
r pum
p11
. Ant
i-ret
urn
valv
e12
. Qui
ck s
huto
ff va
lve
(Onl
y fo
r GP-
1500
)13
. Pre
ssur
e ga
uge
14. D
ual p
urpo
se p
ress
ure
switc
h15
. Con
duct
ed e
scap
e sa
fety
val
ve16
. Mem
bran
e ex
pans
ion
vess
el17
. Qui
ck s
huto
ff va
lve
18. M
otor
pro
tect
ion
GP20
. Flo
w li
mite
r21
. SM
MR
1 Le
vel s
witc
h22
. Dai
ly ta
nk23
. Drip
tray
(inc
lude
d fo
r GP-
800
and
abov
e m
odel
s)24
. Lea
k de
tect
ion
(incl
uded
for G
P-80
0 an
d ab
ove
mod
els)
25. F
ilter
26. P
ress
ure
redu
ctio
n va
lve
(usi
ng p
ress
ure
gaug
e)27
Non
-ret
urn
valv
e28
. Bur
ner
29. B
urne
r inl
et a
ssem
bly
50 51
GP O
IL S
UPPL
Y TO
4 B
URNE
RS
1. M
ain
stor
age
tank
2. S
uctio
n3.
Rem
ote
leve
l gau
ge4.
Con
trol b
ox E
DM-4
0 re
mot
e le
vel g
auge
5. P
ress
ure
unit
“Inp
ro”
GP-3
00 G
ET6.
Filt
er7.
Pre
ssur
e re
duce
r8.
Non
-ret
urn
valv
e9.
Bur
ners
52
GP A
UTOM
ATIC
OIL
SUP
PLY
FROM
2 T
ANKS
TO
3 BU
RNER
S
1. O
il ta
nk2.
Suc
tion
3. F
lexi
ble
prob
e fo
r EDM
-40
2”4.
Fill
cab
inet
for 2
tank
s an
d ED
M-4
05.
Oil
colle
ctin
g tra
y w
ith in
frare
d6.
Pre
ssur
e re
duci
ng v
alve
7. F
ilter
alu
m. b
owl
8. P
ress
ure
redu
cing
val
ve9.
Non
retu
rn v
alve
10. B
urne
rs
52 53
GP G
E OI
L SU
PPLY
TO
A PO
WER
GEN
ERAT
OR
1. M
ain
stor
age
tank
2. R
emot
e le
vel g
auge
3. F
loat
ing
suct
ion
4. V
entil
atio
n te
e5.
Man
hole
6. S
uctio
n pi
pe7.
Filt
er8.
Vac
uum
gau
ge9.
Qui
ck s
huto
ff va
lve
10. E
lect
ric g
ear p
ump
11. A
nti-r
etur
n va
lve
12. Q
uick
shu
toff
valv
e (o
nly
for G
P-15
00)
13. P
ress
ure
gaug
e14
. Dua
l-pur
pose
pre
ssur
e sw
itch
15. C
ondu
cted
esc
ape
safe
ty v
alve
16. 2
mem
bran
es e
xpan
sion
ves
sel (
only
for G
P-15
00)
17. Q
uick
shu
toff
valv
e18
. Ele
ctric
con
trol s
yste
m fo
r the
pre
ssur
e un
it (a
ltern
ativ
e co
mm
and)
20. F
low
lim
iter
21. S
MM
R 1
leve
l sw
itch
22. D
aily
tank
23. Q
uick
shu
toff
valv
e24
. Dra
inin
g va
lve
25. P
ower
gen
erat
or26
. Low
pre
ssur
esw
itch
cuto
ff27
. Qui
ck s
huto
ff va
lve
28.P
ower
gen
erat
or tr
ansf
er p
ump
29. E
lect
rical
ly o
pera
ted
valv
e
54
GP T
O M
ODUL
ATIN
G BU
RNER
1. M
ain
stor
age
tank
2. In
take
pip
e3.
Ove
rfill
prev
entio
n ki
t4.
Rem
ote
leve
l gau
ge E
DM-4
05.
Pre
ssur
e Pu
mp
“Inp
ro G
P”6.
Filt
er7.
Pre
ssur
e re
duct
ion
valv
e (u
sing
pre
ssur
e ga
uge)
8. A
ir ve
nt9.
Mod
ulat
ing
burn
er12
. Res
ervo
ir13
. Mem
bran
e ex
pans
ion
vess
el14
. Sys
tem
dra
inin
g
- El
emen
ts fr
om 6
to 8
and
11
to 1
4 be
long
to In
pro
burn
er in
let a
ssem
bly
(BAM
)
54 55
RL N
OIL
SUP
PLY
OR 2
MOD
ULAT
ING
BURN
ERS
1. M
ain
stor
age
tank
2. S
uctio
n pi
pe3.
Pre
ssur
e un
its “
Inpr
o RL
”4.
Filt
er5.
Qui
ck s
huto
ff va
lve
6. B
urne
rs7.
Ove
rflow
val
ve8.
Bur
ner t
herm
al re
lay
Adju
stab
le a
t ins
talla
tion
from
1 to
4 b
ar
Pum
p st
ops
with
ope
n th
erm
osta
t
56
3 x
Ove
rfill
Ala
rmRL
8 Z
W P
-OIL
SUP
PLY
TO 8
BUR
NERS
1. M
ain
stor
age
tank
2. A
utom
atic
man
ifold
(suc
tion)
3. L
evel
gau
ge p
robe
4. F
ill co
ntro
l cab
inet
5.
RL
8 ZW
ES
6. O
verfl
ow v
alve
7. B
urne
rs 8
800
Kw/h
8. A
utom
atic
man
ifold
(driv
e)9.
Bur
ners
...10
. Bur
ners
...11
. Gas
air
trap
12. F
ilter
0,1
mm
1.0
00 l/
h13
. Filt
er 0
,1 m
m 6
00 l/
h
56 57
GPS
GE O
IL S
UPPL
Y TO
1 B
URNE
R AN
D 1
POW
ER G
ENER
ATOR
1. M
ain
stor
age
tank
2. R
emot
e le
vel g
auge
3. F
loat
ing
suct
ion
4. M
anho
le5.
Ven
tilat
ion
tee
6. In
take
pip
e7.
Filt
er8.
Vac
uum
gau
ge9.
By-
pass
val
ve10
. Ele
ctric
gea
r pum
p11
. Ant
i-ret
urn
valve
12. S
afet
y / s
ervic
e sw
itche
s (le
vel)
13. T
ank
14. L
eak
dete
ctio
n15
. Drip
tray
16. Q
uick
shu
toff
valve
17. G
ener
ator
uni
t18
. Bur
ner
58
GPS
N OI
L SU
PPLY
TO
2 BU
RNER
S
1. M
ain
stor
age
tank
2. R
emot
e le
vel g
auge
3. F
loat
ing
suct
ion
4. M
anho
le5.
Ven
tilat
ion
tee
6. In
take
pip
e7.
Filt
er8.
Vac
uum
gau
ge9.
By-
pass
val
ve10
. Ele
ctric
gea
r pum
p11
. Ant
i-ret
urn
valve
12. S
afet
y / s
ervic
e sw
itche
s (le
vel)
13. T
ank
14. L
eak
dete
ctio
n15
. Drip
tray
18. B
urne
rs
58 59
GPS
VERS
ION
“DRU
CK”:
OIL
SUP
PLY
SUCT
ION
AND
PRES
SURE
SY
STEM
FOR
ROO
F BU
RNER
S
1. M
ain
stor
age
tank
2. R
emot
e le
vel g
auge
3. F
loat
ing
suct
ion
4. M
anho
le5.
Ven
tilat
ion
tee
6. S
uctio
n pi
pe7.
Filt
er8.
Vac
uum
gau
ge9.
Qui
ck s
huto
ff va
lve10
. Ele
ctric
gea
r pum
p11
. Ant
i-ret
urn
valve
12. S
afet
y / s
ervic
e sw
itche
s (le
vel)
13. T
ank
14. L
eak
dete
ctio
n15
. Drip
tray
16. P
ress
ure
gaug
e17
. Dua
l pur
pose
pre
ssur
e sw
itch
18. C
ondu
cted
esc
ape
safe
ty v
alve
19. M
embr
ane
expa
nsio
n ve
ssel
20. P
ress
ure
redu
ctio
n va
lve (u
sing
pre
ssur
e ga
uge)
21. N
on-r
etur
n va
lve22
. Bur
ner
60
FP Z
W O
IL S
UPPL
Y TO
A D
AILY
TAN
K
1. M
ain
stor
age
tank
2. R
emot
e le
vel g
auge
3. F
loat
ing
suct
ion
4. M
anho
le5.
Filt
er6.
Con
trol p
anel
7. Q
uick
shu
toff
valve
8. P
umps
type
FP
9. C
ondu
cted
esc
ape
safe
ty v
alve
10. A
nti-r
etur
n va
le11
. Drip
tray
12. F
lexib
le p
robe
13. S
MM
R Le
vel s
witc
h14
. Dai
ly Ta
nk
60 61
WIR
ING
DIAG
RAM
FOR
ANA
LOG
AND
RELA
Y CO
NNEC
TION
S
Whe
n le
vel i
ncre
ases
up
to 8
0%, c
onta
ct 1
5-17
clo
seW
hen
leve
l inc
reas
es u
p to
63%
, con
tact
25-
27 c
lose
Whe
n le
vel d
ecre
ases
till
42%
, con
tact
25-
26 c
lose
Whe
n le
vel d
ecre
ases
till
25%
, con
tact
15-
16 c
lose
230V
-50 H
z
62
OIL T
RANS
FER
TO B
URNE
R W
ITH
GPS
PUMP
SET,
STOR
AGE
TANK
IN S
IPHO
N
1. Ma
in sto
rage
tank
2. Su
ction
pipe
3. ED
M-40
remo
te lev
el pr
obe
4. ED
M-40
remo
te lev
el ga
uge
5. GP
S gr
oup t
rans
fer In
pro
6. NC
Sole
noid
valve
7. Bu
rner
62
64