> port size: 3/4“ 1 1/2“ > controlled increase of (iso g...
TRANSCRIPT
![Page 1: > Port size: 3/4“ 1 1/2“ > Controlled increase of (ISO G ...img66.chem17.com/1/20161104/636138568578989859521.pdf · component parts used in fluid power systems and to provide](https://reader031.vdocument.in/reader031/viewer/2022013019/5e010ea071901c21376e084b/html5/thumbnails/1.jpg)
P68F - Olympian Plus plug-in system Soft start/dump valves
05/16en 8.260.610.01
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2002 - 8097f) © 2015 IMI International s.r.o.
Technical featuresMedium:Compressed air only Operating pressure:3 bar (43 psi) minimum Solenoid actuated: 10 bar (145 psi) maximum Pilot actuated: 17 bar (246 psi) maximumSnap pressure:Full flow when downstream pressure reaches 50 ... 80% of inlet pressureCharge time:For 25 litre (845 fluid oz) downstream volume and 6,3 bar (90 psi) inlet pressure 6,4 sec. minimum 115 sec. maximum
Flow:147 dm3/s (312 scfm) (P1 » P2 = Cv 11,2) (P2 » P3 = Cv >11) Operating pressure: 6,3 bar (91 psi) Δp: 0,5 bar (7 psi) Port sizes:3/4”, 1”, 1 1/4” or 1 1/2”Air pilot port:G1/4 with ISO G main ports1/4 PTF with PTF main portsExhaust port:G1 with ISO G main ports1” PTF with PTF main portsGauge port:1/8 PTF with PTF main portsRc1/8 with ISO G main ports
Ambient/Media temperature:Solenoid actuated: -20° ... +50°C ( -4 ... +149°F) Pilot actuated: -20° ... +80°C ( -4 ... +176°F) Version with gauge: -20° ... +65°C (-4° ... +149°F) Air supply must be dry enough to avoid ice formation at temperatures below +2°C (+35°F).
Materials:Body, yoke, top and bottom plate: AluminiumFilter discs: Sintered plasticInternal components: Brass/steel Elastomers: NBR
> Port size: 3/4“ ... 1 1/2“ (ISO G/PTF)
> Assists machine designers in complying with the European Machineries Directive
> Can help existing machinery to comply with PUWER (Provision and Use of Work Equipment Regulations
> Controlled increase of downstream pressure on start up
> Solenoid, air pilot or manual operator
> High forward flow capacity
> High flow dump facility
Technical data - standard modelsSymbol Port size Size Actuation/
returnVoltage Pilot port Weight
(kg)Typ
2
1 3
G3/4 — Solenoid/spring 24 V d.c. — 2,95 P68F-6GC-PFA *1)
G1 — Solenoid/spring 24 V d.c. — 2,93 P68F-8GC-PFA *1)
G1 1/4 Basic Solenoid/spring 24 V d.c. — 2,90 P68F-AGC-PFA *1)
G1 1/2 — Solenoid/spring 24 V d.c. — 2,92 P68F-BGC-PFA *1)
Without yoke Solenoid/spring 24 V d.c. — P68F-BGC-PFA *1)
2
1 3
G3/4 — Air/spring — 1/4” 2,77 P68F-6GA-NNN
G1 — Air/spring — 1/4 2,75 P68F-8GA-NNN
G1 1/4 Basic Air/spring — 1/4 2,72 P68F-AGA-NNN
G1 1/2 — Air/spring — 1/4 2,74 P68F-BGA-NNN
Without yoke Air/spring — 1/4 P68F-NNA-NNN
*1) To select other solenoid type and coil voltage refer to option selector on page 2
Electrical details for solenoid operatorsVoltage tolerance ± 10%
Rating 100% continuous duty
Inlet orifice 1,0 mm
Electrical connection Industrial Standard, 22 mm
Solenoid coil mounting Four positions x 90°
Protection class IP 65 (with sealed plug)
22 mm coil for connector interface acc. to industrial standard
Voltage Power Inrush/Hold
Model Code
12 V d.c. 2 W QM/48/12J/21 12J
24 V d.c 2 W QM/48/13J/21 13J
110/120 V 50/60 Hz 4/2,5 VA QM/48/18J/21 18J
220/240 V 50/60 Hz 6/5,0 VA QM/48/19J/21 19J
Voltage codes and spare coils Connector plugs Industrial standard 22 mm 2-pole + PE
0657868
![Page 2: > Port size: 3/4“ 1 1/2“ > Controlled increase of (ISO G ...img66.chem17.com/1/20161104/636138568578989859521.pdf · component parts used in fluid power systems and to provide](https://reader031.vdocument.in/reader031/viewer/2022013019/5e010ea071901c21376e084b/html5/thumbnails/2.jpg)
P68F - Olympian Plus plug-in system Soft start/dump valves
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2002 - 8097f) © 2015 IMI International s.r.o.en 8.260.610.02
05/16
Out
let
pre
ssur
e
P68F-˙˙˙-˙˙˙Option selector
Port size Substitute
3/4“ 6
1” 8
1 1/4” A
1 1/2” B
Without yoke N
Threads Substitute
PTF A
ISO G parallel (standard) G
No yoke (standard) N
Operator Substitute
Air pilot (standard) A
Air pilot with manual lockout B
22 mm solenoid (standard) C
22 mm solenoid with manual lockout
D
Connector Substitute
3 pin plug with cable gland A
Without N
Voltage Watts Substitute
24 V d.c. 2 W F
12 V d.c. 2 W E
6 V d.c. 2 W D
220/240 V, 50/60 Hz 4/2,5 VA B
110/120 V, 50/60 Hz 4/2,5 VA A
No coil – Z
No solenoid – N
Manual override Substitute
Non-locking, shrouded push button P
None N
Flow characteristics
Air flow
Charge time
Inlet pressure bar (psi)
25 liter volume
Pre
ssur
e d
rop
Δ p
Maximum charge time
0 50 100 150 200 250 dm3/s
0 100 200 300 400 500 600 scfm
0,8
0,6
0,4
0,2
0
bar
10
8
6
4
2
0
psi
3(44)
6,3(91)
4,0(58)
10(150)
12.5(180)
14(203)
8(116)
0 20 40 60 80 100 120
16
12
8
4
0
bar
200
160
120
80
40
0
psi
Snap Point
![Page 3: > Port size: 3/4“ 1 1/2“ > Controlled increase of (ISO G ...img66.chem17.com/1/20161104/636138568578989859521.pdf · component parts used in fluid power systems and to provide](https://reader031.vdocument.in/reader031/viewer/2022013019/5e010ea071901c21376e084b/html5/thumbnails/3.jpg)
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2002 - 8097f) © 2015 IMI International s.r.o.
P68F - Olympian Plus plug-in system Soft start/dump valves
en 8.260.610.0305/16
Thread
Single yoke Double yoke End connector kit
Single yoke non threads
3/2 Shut-off valveThreaded inlet only Threaded outlet only
Bracket mounting
G3/4 Y68A-6GN-N1N Y68A-6GN-N2N 5524-55 74785-98 T68H-6GB-B2N T68H-6GC-B2N 18-001-979
G1 Y68A-8GN-N1N Y68A-8GN-N2N 5524-52 T68H-8GB-B2N T68H-8GC-B2N 18-001-979
G1 1/4 Y68A-AGN-N1N Y68A-AGN-N2N 5523-52 T68H-AGB-B2N T68H-AGC-B2N 18-001-978
G1 1/2 Y68A-BGN-N1N Y68A-BGN-N2N 5523-93 T68H-BGB-B2N T68H-BGC-B2N 18-001-972
3/4 PTF Y68A-6AN-N1N Y68A-6AN-N2N 5524-53 T68H-6AB-B2N T68H-6AC-B2N 18-001-979
1 PTF Y68A-8AN-N1N Y68A-8AN-N2N 5524-50 T68H-8AB-B2N T68H-8AC-B2N 18-001-979
1 1/4 PTF Y68A-AAN-N1N Y68A-AAN-N2N 5523-50 T68H-AAB-B2N T68H-AAC-B2N 18-001-978
1 1/2 PTF Y68A-BAN-N1N Y68A-BAN-N2N 5523-95 T68H-BAB-B2N T68H-BAC-B2N 18-001-972
Nut Silencer Porting block
5520-89 MB008B (R1) 18-026-986 (G1/4 & G1/2)
MB008A (1 NPT) 18-026-983 (1/4 & 1/2 NPT)
Accessories
GaugesCenter back connection, white face (full technical specification see datasheet 8.900.900)
Pressure range bar *1 Mpa psi Ø Thread size Model
0 ... 4 0 ... 0,4 0 ... 58 50 mm R1/8 18-013-011
0 ... 10 0 ... 1 0 ... 145 50 mm R1/8 18-013-013
0 ... 25 0 ... 2,5 0 ... 362 50 mm R1/8 18-013-014
*1) primary scale
Center back connection, black face for North America (full technical specification see datasheet 8.900.900)
1 2 3 4 5 6 7 8 9 10
11 12 13 14 15 16 17 18 19 20
20
30
21 22 23 24 25 26 27 28 29
31 32 33 34 35 36 37 38 39
Pressure range psig *1 bar Mpa Ø Thread size Model
0 ... 60 0 ... 4 0 ... 0.4 2” (50 mm) 1/8 NPT 18-013-202
0 ... 160 0 ... 11 0 ... 1.1 2” (50 mm) 1/8 NPT 18-013-204
0 ... 400 0 ... 28 0 ... 2.8 2” (50 mm) 1/8 NPT 18-013-206
*1) primary scale
![Page 4: > Port size: 3/4“ 1 1/2“ > Controlled increase of (ISO G ...img66.chem17.com/1/20161104/636138568578989859521.pdf · component parts used in fluid power systems and to provide](https://reader031.vdocument.in/reader031/viewer/2022013019/5e010ea071901c21376e084b/html5/thumbnails/4.jpg)
P68F - Olympian Plus plug-in system Soft start/dump valves
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2002 - 8097f) © 2015 IMI International s.r.o.en 8.260.610.04
05/16
Dimensions
StandardPilot actuated
Solenoid actuatedStandard
With manual lockout
With manual lockout
Dimensions in mm Projection/First angle
# Minimum clearance required to remove unit from yoke 1 Main ports 3/4”, 1”, 1 1/4” or 1 1/2” 2 Pilot port 1/4” 3 Plus 10 mm for ports 1 1/4” or 1 1/2”7 Gauge port 1/8” 8 Exhaust port 1”
63
167
191
#10
0
147
10
90
5 or 3/16”7
190 3
11
8
2
147
10
90
63
245
269
#10
0
190 3
11
8
5 or 3/16”7
![Page 5: > Port size: 3/4“ 1 1/2“ > Controlled increase of (ISO G ...img66.chem17.com/1/20161104/636138568578989859521.pdf · component parts used in fluid power systems and to provide](https://reader031.vdocument.in/reader031/viewer/2022013019/5e010ea071901c21376e084b/html5/thumbnails/5.jpg)
Our policy is one of continued research and development. We therefore reserve the right to amend, without notice, the specifications given in this document. (2002 - 8097f) © 2015 IMI International s.r.o.
P68F - Olympian Plus plug-in system Soft start/dump valves
en 8.260.610.0505/16
1 For 1 1/2” ported yokes add 5 mm 1 Two additional plugged G1/4 ports
6243
95
ø 20
1/4”
100
801
1/2”
108
29
1
3/2 Shut-off valve Porting block
208
190
15
125
100
72
125,
5
2,5
190
4
8,5
1
1
1
333
315
12595
15
125
100
72 2,5
315
4
9
8,5
125,
51
1
1
1 For 1 1/4” and 1 1/2” ported yokes add 10 mm 1 For 1 1/4” and 1 1/2” ported yokes add 10 mm
Single yoke with bracket Double yoke with bracket
Warning
These products are intended for use in industrial compressed air systems only. Do not use these products where pressures and temperatures can exceed those listed under »Technical features/data«.Before using these products with fluids other than those specified, for non-industrial applications, life-support systems or other applications not within published specifications, consult IMI Precision Engineering, IMI International s.r.o.Through misuse, age, or malfunction, components used in fluid power systems can fail in various modes.
The system designer is warned to consider the failure modes of all component parts used in fluid power systems and to provide adequate safeguards to prevent personal injury or damage to equipment in the event of such failure.System designers must provide a warning to end users in the system instructional manual if protection against a failure mode cannot be adequately provided.System designers and end users are cautioned to review specificwarnings found in instruction sheets packed and shipped with these products.
Diese Produkte sind ausschließlich in Druckluftsystemen zu verwenden. Sie sind dort einzusetzen, wo die unter »Technische Merkmale/-Daten« aufgeführten Werte nicht überschritten werden. Berücksichtigen Sie bitte die entsprechende Katalogseite. Vor dem Einsatz der Produkte bei nicht industriellen Anwendungen, in lebenser-haltenden- oder anderen Systemen, die nicht in den veröffentlichten Anleitungsunterlagen enthalten sind, wenden Sie sich bitte direkt an IMI Precision Engineering, IMI International s.r.o.Durch Missbrauch, Verschleiß oder Störungen können in Pneumatik-
systemen verwendete Komponenten auf verschiedene Arten versagen.Systemauslegern wird dringend empfohlen, die Störungsarten aller in Pneumatiksystemen verwendeten Komponententeile zu berück-sichtigen und ausreichende Sicherheitsvorkehrungen zu treffen, um Verletzungen von Personen sowie Beschädigungen der Geräte im Falle einer solchen Störung zu verhindern. Systemausleger sind verpflichtet, Sicherheitshinweise für den End-benutzer im Betriebshandbuch zu vermerken, wenn der Störungs-schutz nicht ausreichend gewährleistet ist.
Te produkty są przeznaczone do pracy wyłącznie w przemysłowych układach ze sprężonym powietrzem i płynami. Nie używać produktów tam, gdzie ciśnienia i temperatury mogą przekroczyć parametry podane w sekcji „Cechy/Dane techniczne”. Przed użyciem produktów z płynami innymi niż określono i w celach innych niż przemysłowe, w systemach podtrzymywania życia i w innych zastosowaniach niewymienionych w opublikowanych specyfikacjach należy skontaktować się z IMI Precision Engineering, IMI International s.r.o.W wyniku niewłaściwego użytkowania lub procesów zużycia oraz usterek,
zastosowane komponenty w pneumatycznych i hydraulicznych układach zasilających mogą ulec awarii.Przestrzega się konstruktorów do zastosowania wszelkich środków bezpieczeństwa w celu uniknięcia obrażeń osobistych i zniszczenia mienia na wypadek awarii komponentów zastosowanych w układzie zasilania.Przestrzega się konstruktorów układów, aby zapoznać się ze szczególnymi ostrzeżeniami zamieszczonymi na kartach danych z instrukcjami, które są pakowane i wysyłane razem z produktami.
Les produits de ce catalogue ne conviennent que pour les systèmesindustriels fonctionnant à l‘air comprimé. Ne jamais soumettre cesappareils à des pressions ou à des températures autres que cellesindiquées dans les caractéristiques techniques.Pour une utilisation avec un fluide non spécifié dans cette fichetechnique, les applications non industrielles, les appareils derespiration artificielle ou toute autre application ne correspondant pasà nos spécifications, consultez notre service technique IMI Precision Engineering, IMI International s.r.o.Une utilisation abusive, l’âge des appareils ou leur manque d’entretienpeuvent entraîner différents types de dysfonctionnements.
Il est conseillé aux concepteurs de machines d’étudier tous les modesde défaillance de chacun des composants et de prévoir les protectionsnécessaires de manière à éviter tout accident corporel ou toutdommage aux systèmes environnants en cas de défaillance de l’un deceux-ci.Lorsqu‘une protection appropriée ne peut être installée, le concepteurde machine devra informer les utilisateurs des risques encourus parune mention portée dans sa notice d’utilisation.Il est recommandé aux concepteurs de systèmes et aux utilisateurs deprendre connaissance des mises en garde portées sur les feuilletsfournis avec les appareils ou bien indiquées directement sur ces derniers.
Estos productos están destinados a que se utilicen únicamente ensistemas industriales de aire comprimido. No utilizar estos productoscuando la presión y temperatura puedan exceder las especificadasen los ‘Datos Técnicos ’.Antes de utilizar estos productos con fluidos que no sean losespecificados, para aplicaciones no industriales, sistemas médicosanitarios u otras aplicaciones que no se encuentren entre las especificaciones publicadas, consultar IMI Precision Engineering, IMI International s.r.o.Por mal uso, antigüedad o montaje deficiente, los componentesutilizados en sistemas de fluidos energéticos pueden fallar y provocardiversos tipos de accidentes.
Se advierte a los diseñadores de sistemas que deben considerar laposibilidad de mal funcionamiento de todos los componentes utilizadosen sistemas de fluidos y prever las medidas adecuadas de seguridadpara evitar daños personales o desperfectos en el equipo en elsupuesto de producirse tales fallos.En el caso de no poder proporcionar la protección adecuada frente aalgún fallo, los diseñadores del sistema deben advertirlo al usuario finalen el manual de instrucciones.Se aconseja a los diseñadores del sistema, así como a los usuariosfinales, que revisen las advertencias especificadas de montaje que seindican en las hojas técnicas.
Questi prodotti sono adatti solo per l’impiego in impianti industrialifunzionanti con aria compressa. Non devono essere utilizzati nei casiin cui le condizioni di pressione e di temperatura non rientrino nei valoriindicati nelle ‘Caratteristiche Tecniche’.Prima di utilizzare questi prodotti con fluidi differenti da quelli indicati,per applicazioni non industriali, sistemi medico-sanitari o altreapplicazioni non specificatamente indicate nella documentazione,consultare la IMI Precision Engineering, IMI International s.r.o.In seguito all’utilizzo errato, l’invecchiamento o al mal funzionamento,
i componenti utilizzati in impianti pneumatici possono danneggiarsi. I progettisti degli impianti devono prendere in considerazione tutte lepossibilità di rottura dei componenti utilizzati nell’impianto pneumatico eprevedere dispositivi di sicurezza per evitare lesioni all’operatore odanneggiamenti all’impianto.Se le protezioni non sono adeguatamente sicure, il progettistadeve informare l’utilizzatore finale nel Manuale di Istruzione.Si consiglia agli utilizzatori ed ai progettisti di prendere inconsiderazione
EN
DE
PL
ES
FR
IT
Dimensions in mm Projection/First angle
Silencer
A B C D Model
R1 23 138 51 51 MB008B
1 NPT 23 138 51 51 MB008A
C
Ø D
B
A