03 sep 600 communication and project setup
TRANSCRIPT
-
8/12/2019 03 SEP 600 Communication and Project Setup
1/16
SA-T TrainingOctober 20, 2010 | Slide 11MRG003731
Protection and control IED managerPCM600Communication and project setup
SA-T TrainingOctober 20, 2010 | Slide 21MRG003731
Section 3
Communication setup at
IED side
PC side
PCM600 project handling
Creation/deletion of projects
Handling of IED objects
License Update (read order options)
Technical key (only for 650 series)
Export/Import
Report parameters
HW tool
Contents
-
8/12/2019 03 SEP 600 Communication and Project Setup
2/16
SA-T TrainingOctober 20, 2010 | Slide 31MRG003731
Section 3
With this presentation You will learn
What is needed to establish the communication between the physical
IED and PCM600. How to set IP addresses for the IED objects in PCM600 and also for the
engineering PC itself running PCM600
Impact of sub networks
How to manage projects with PCM600
Creation of projects
Deletion of projects
Import/export functionality
Basic HW configuration done with the HW tool
What to learn with this chapter
SA-T TrainingOctober 20, 2010 | Slide 41MRG003731
Section 3
Communication protocols
TCP/IP
IEC61850 communication connectivitypackage used
SPA (only 670 series)
LON (only 670 series)
IED Ethernet ports
Front port
Galvanic
Rear port(s)
Optic
Two channels possible for 670 series
One channel only for 650 series
Communication setup IED PC
-
8/12/2019 03 SEP 600 Communication and Project Setup
3/16
SA-T TrainingOctober 20, 2010 | Slide 51MRG003731
Section 3
IED Front port
Default IP address 10.1.150.3
Default Subnet mask 255.255.255.0
PC port setting
IP address 10.1.150.1 up to 254
Subnet mask 255.255.255.0
Crossed over Ethernet cable
If direct connection from PC to IED
IED Front has DHCP server Dynamically assign IP address to the PC
Ethernet IED Front connection
SA-T TrainingOctober 20, 2010 | Slide 61MRG003731
Section 3Ethernet Optic network
RX TX RX TX
Ethernet switch
IP: 172.16.0.11
Optical cable
IP: 172.16.0.10
IP: 172.16.0.12
IP: 172.16.0.13
IED Rear port
Default IP address 192.168.1.10
Default Subnet mask 255.255.255.0
This is an example of Class B networkaddressing concept
The two first segments
Defines the Network
The two last segments
Define the Nodes
Rear Ethernet port NO DHCP server
Note! All devices that shall communicatewith each other must belong to the samesub network
Mask: 255.255.0.0
Mask: 255.255.0.0
Mask: 255.255.0.0
Mask: 255.255.0.0
-
8/12/2019 03 SEP 600 Communication and Project Setup
4/16
SA-T TrainingOctober 20, 2010 | Slide 71MRG003731
Section 3
Ethernet port settings at PC side
No settings in PCM600 for Ethernet port of PC, use WINDOWS control panel
Set TCP/IP properties on the connection to be used for the PCM600/IED communication
SA-T TrainingOctober 20, 2010 | Slide 81MRG003731
Section 3IED Ethernet port settings
The IP address of the IEDobject in PCM600 can be set intwo ways;
When creating the IED object in
PCM600, the IP address can beset in the ConfigurationWizard
Opening Properties at IEDlevel object and changing theIP Address property
-
8/12/2019 03 SEP 600 Communication and Project Setup
5/16
SA-T TrainingOctober 20, 2010 | Slide 91MRG003731
Section 3
PCM600 project handling
Manage projects
Create the plant structure
Create the IED objects
SA-T TrainingOctober 20, 2010 | Slide 101MRG003731
Section 3Manage Projects
Open/Manage projects
Create projects
Delete projects
Export projects
All data within the PCM600project is exported to a file withextension .pcmp.Used for back-up purposes.
Import projects
Use earlier exported .pcmp file
Rename projects
-
8/12/2019 03 SEP 600 Communication and Project Setup
6/16
SA-T TrainingOctober 20, 2010 | Slide 111MRG003731
Section 3
Create the Plant Structure
Two ways to create objects;
Drag and drop from object types
Right click on object, select New
When creating IED objects, theconfiguration wizard isautomatically started
Note:Only one substation level is allowed
SA-T TrainingOctober 20, 2010 | Slide 121MRG003731
Section 3Create the IED objects
Configuration modes
Online configuration
IED available
Offline configuration
No IED available
Use order files
Note: Not possible to
communicate betweenPCM600 and IED via SPAand LON for the 650 series
Select the protocol to usefor the PCM600/IEDcommunication
-
8/12/2019 03 SEP 600 Communication and Project Setup
7/16
SA-T TrainingOctober 20, 2010 | Slide 131MRG003731
Section 3
Create the IED objects, Online configuration
Set IP address to use
Different default valuesfor Front and Rear
port, otherwise nomeaning with the Portselection
IED type, version, display type (Local HMI) andhousing (size of the IED) is automaticallydetected in online mode (Use the Scan button)
SA-T TrainingOctober 20, 2010 | Slide 141MRG003731
Section 3Create the IED objects, Offline configuration
IED version must be selectedmanually
Order option file available
Enables only ordered SW and HW
in PCM600 No need to synchronize PCM600
and physical IED
No order option file available
Enables all functionality in PCM600
Need to synchronize PCM600 andphysical IED, use the LicenseUpdate Tool
Possible to configure functionality in
PCM600 that later will not beaccepted by the IED
-
8/12/2019 03 SEP 600 Communication and Project Setup
8/16
SA-T TrainingOctober 20, 2010 | Slide 151MRG003731
Section 3
Plant Structure, basics
Two main sections
IED configuration structure
Contains basic functionality such as forexample communication addresses andHW
Application configuration structure
Contains the configuration dataconfigured with ACT.
Synchronized with the Main Applicationstructure configured with ACT.
SA-T TrainingOctober 20, 2010 | Slide 161MRG003731
Section 3License update Tool
Synchronizes PCM600 IED object withphysical IED capabilities when it comesto;
Function options
Hardware options
-
8/12/2019 03 SEP 600 Communication and Project Setup
9/16
SA-T TrainingOctober 20, 2010 | Slide 171MRG003731
Section 3
Technical Key(not applicable for 670 series)
Is used for security reasons, moredifficult to communicate with the wrongIED since the technical key at IEDobject in PCM600 and in physical IEDmust match.
Unique identifier for each object in thePlant Structure
Is set automatically by PCM600
Can be modified by the user
To synchronize PCM600 and IED
technical key, use the Set TechnicalKey Tool
To change the technical key inPCM600 only, go to object propertiesfor the IED object
SA-T TrainingOctober 20, 2010 | Slide 181MRG003731
Section 3Set Technical Key
Technical key options
Use IED Technical key
Use PCM600 Technical key User-defined Technical key
No special characters
Max length 13 characters
No numbers in the beginning
Note that changing the Technical keymight have an impact on the IEC61850configuration in your system
-
8/12/2019 03 SEP 600 Communication and Project Setup
10/16
SA-T TrainingOctober 20, 2010 | Slide 191MRG003731
Section 3
Export IED object
Purpose: Make backup of and reuse aconfigured IED
Contains all configured data for the IED Application Configuration
Signal Matrix
Parameter Setting
Graphical Display
Communication Management (DNP)
SCL information
Hardware configuration
File extension is .pcmi
SA-T TrainingOctober 20, 2010 | Slide 201MRG003731
Section 3Import IED object
Purpose: To reuse a previouslyconfigured IED object (pcmi file)
Import of pcmi files can be made at theBay level object in PCM600
-
8/12/2019 03 SEP 600 Communication and Project Setup
11/16
SA-T TrainingOctober 20, 2010 | Slide 211MRG003731
Section 3
Create Template
Purpose: To reuse a configured IED
In a pre-defined place
For quick access
Creation of template
Right click IED object
Creates a .pcmt file
Ends up in PCMDatabases\Templates
Contains all configured data
Same contents as the pcmi file
SA-T TrainingOctober 20, 2010 | Slide 221MRG003731
Section 3Create new IED object from Template
Purpose: To reuse a configured IED
Initiated from the Bay level object
New->Create from Template
Templates structured based on IEDtype
-
8/12/2019 03 SEP 600 Communication and Project Setup
12/16
SA-T TrainingOctober 20, 2010 | Slide 231MRG003731
Section 3
IEC 61850 configuration SCD
SCD file
Substations Configuration Description
Contents
SCL information for all IEDs within thesubstation
Export/Import of SCD file
Done at Substation level
SCL engineering done outsidePCM600, export/import functionality
needed.
Note! When importing SCL files to PCM600, be sure to import an SCLfile that correlates with the PCM600 project or you might loose data
SA-T TrainingOctober 20, 2010 | Slide 241MRG003731
Section 3IEC 61850 configuration ICD
ICD file
IED Capability Description
Contents
All thats configured in the IED beforethe system configuration
No SA Section
No Communication section
IEDName = TEMPLATE
Usage
System engineering
Merging to an SCD file
Export/Import of ICD file
At IED level
-
8/12/2019 03 SEP 600 Communication and Project Setup
13/16
SA-T TrainingOctober 20, 2010 | Slide 251MRG003731
Section 3
IEC 61850 configuration CID
CID file
Configured IED Description
Contents
Extract of the SCD file
SCL information for one specific IED
Export/Import of ICD file
At IED level
SA-T TrainingOctober 20, 2010 | Slide 261MRG003731
Section 3Report Parameters
Footer information for printouts
Application configuration
Local display, Graphical display editor
Parameter settings
Communication management
-
8/12/2019 03 SEP 600 Communication and Project Setup
14/16
SA-T TrainingOctober 20, 2010 | Slide 271MRG003731
Section 3
Hardware Configuration
Possible to manually configure HW/slot positions
This information is already available if you havecreated the IED object in online mode
Select correct card type in correct slot position
SA-T TrainingOctober 20, 2010 | Slide 281MRG003731
Section 3Hardware Configuration
Compare configuration
Reads hardware configuration from theIED and compares with the HWconfiguration made in PCM600
Make sure that the HW configurationmatches with your physical IED beforeyou do any other configuration e.g. withACT or SMT otherwise you might need tospend time on reconfiguration.
-
8/12/2019 03 SEP 600 Communication and Project Setup
15/16
SA-T TrainingOctober 20, 2010 | Slide 291MRG003731
Section 3
Hardware Configuration, parameterization
Parameter Setting
Short-cut to parameters/settings for
the HW when HW tool is open Select HW module from hardware
configuration list
Press Parameter Setting button intoolbar menu that will issue the PST
Only change of parameters possiblewhen opening PST from the HWtool.Read/Write with the IED done fromordinary PST, e.g. open PST from
the Plant Structure.
SA-T TrainingOctober 20, 2010 | Slide 301MRG003731
Section 3Time for exercise!Ex 2
-
8/12/2019 03 SEP 600 Communication and Project Setup
16/16
SA-T TrainingOctober 20, 2010 | Slide 311MRG003731
Section 3