04 pdm tools en
TRANSCRIPT
![Page 1: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/1.jpg)
PacDriveMTools
![Page 2: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/2.jpg)
2ToolsSchneider Electric Automation GmbH
� PacDrive NetManage
� PacDrive Diagnostics
� PacDrive Backup
� Sercos – Firmware Assistant
Tools on Service CD
![Page 3: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/3.jpg)
3ToolsSchneider Electric Automation GmbH
� PacDriveNetManage scans network and finds Controllers, which have minimumFirmware V15.
� With PacDriveNetManage you get Informations about network settings,Project and Firmware of the Controller
� Change of network settings are possible
� Call:
PacDriveManageCall
![Page 4: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/4.jpg)
4ToolsSchneider Electric Automation GmbH
PacDriveManageHandling
![Page 5: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/5.jpg)
5ToolsSchneider Electric Automation GmbH
� Diagnosis tool for reading out project datas without EPAS-4
� PD Diagnostics is only a minimal load, so working on a running machine is possible
� Call:
PacDriveDiagnosticsCall
![Page 6: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/6.jpg)
6ToolsSchneider Electric Automation GmbH
PacDriveDiagnosticsStartpage
![Page 7: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/7.jpg)
7ToolsSchneider Electric Automation GmbH
PacDriveDiagnosticsEvaluation
![Page 8: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/8.jpg)
8ToolsSchneider Electric Automation GmbH
� Firmware consists of software routines which are storedon a non-volontile storage
�Firmware is responsible for the ‚playing together‘ of Hardware and Software.
� Storage :
� Controller - Firmware is stored on the flash
� MotorController - Firmware is stored on anEEPROM
FirmwareNotation
![Page 9: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/9.jpg)
9ToolsSchneider Electric Automation GmbH
� For a correct working of software commands it´s necessary that:
� EPAS-4 Version higher or equal of project version(identical to Controller firmware version)
� Firmwareversion of Controller is higher or equal toFirmwareversion of Drive (MC-4, SCL, iSH )
FirmwareHirarchy
![Page 10: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/10.jpg)
10ToolsSchneider Electric Automation GmbH
� If previous condition are not given you get in case of higher FW-Version
drive than Controlller following diagnosis message:
(see also OnlineHelp)
FirmwareDiagnosis message 509
![Page 11: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/11.jpg)
11ToolsSchneider Electric Automation GmbH
Controller C600:Firmwareversion 20.02
FirmwareController folder ‚Version‘
![Page 12: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/12.jpg)
12ToolsSchneider Electric Automation GmbH
Default path of FirmwareC:\ProgramFiles\ELAU
All tools are to be set as standardfolder onto that path. Tools opensubfolder according your selection.
FirmwareFirmware folder
![Page 13: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/13.jpg)
13ToolsSchneider Electric Automation GmbH
� Firmware change� Formatting aFlash� Create Backup
� Call
PROGRAMFILES | ELAU | PacDriveBackup
PacDriveBackupCall and start page
![Page 14: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/14.jpg)
14ToolsSchneider Electric Automation GmbH
Direct Writing
PacDriveBackupCreate a Backup
![Page 15: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/15.jpg)
15ToolsSchneider Electric Automation GmbH
� Firmwarechange with DriveBackup
� can take place with built in flash
� deletes program- and configuration file
� copys selected firmware onto the flash
� copys a minimal configuration file with selected
IP-Settings onto the flash
PacDriveBackupFirmware change
![Page 16: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/16.jpg)
16ToolsSchneider Electric Automation GmbH
Auswahl: Upgrade / Update
Selection: Controllertype and Firmware
Adapt IP-Settings
Hint: for first call you
must create fira an image
PacDriveBackupFirmware change Controller
![Page 17: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/17.jpg)
17ToolsSchneider Electric Automation GmbH
Write to controller
After bootsequence error LED flashes, because program and configuration file have beendeleted !!
PacDriveBackupFirmware change Controller
![Page 18: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/18.jpg)
18ToolsSchneider Electric Automation GmbH
Selection: Controllertype and Firmware Adapt IP-settings
PacDriveBackupCreating a Flash with OS
![Page 19: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/19.jpg)
19ToolsSchneider Electric Automation GmbH
Write to flash in Reader / Writer
PacDriveBackupCreate a Flash with OS
![Page 20: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/20.jpg)
20ToolsSchneider Electric Automation GmbH
MotorController MC-4:Firmwareversion 20.01
FirmwareMC-4 folder ‚Controller‘
![Page 21: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/21.jpg)
21ToolsSchneider Electric Automation GmbH
� Call of SERCOS Firmware-Assistenten
PROGRAMFILES | ELAU | SERCOS Firmware Assistent
� Change via TCP / IP
� Fw change of different devises in one step (MC-4, PS-4, SCL055, iSH)
� Automatical recognition of drives within SERCOS-Bus
� Conditions
� Hardwareversion Dirve minimum Cxxxxx
� Actual Firmwareversion minimum 15.xx
PacDriveSercos Firmwaree AssistantFirmware change of Drives
![Page 22: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/22.jpg)
22ToolsSchneider Electric Automation GmbH
PacDriveSercos Firmwaree AssistantFirmware change of Drives
![Page 23: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/23.jpg)
23ToolsSchneider Electric Automation GmbH
PacDriveSercos Firmwaree AssistantFirmwarechange of Drives
![Page 24: 04 PDM Tools en](https://reader035.vdocument.in/reader035/viewer/2022062604/62b532fa2a65fa78cc6b6d92/html5/thumbnails/24.jpg)
24ToolsSchneider Electric Automation GmbH
� Change via COM – Interface
with Bootloader kcable (single device)
MC-4X7
PCCom 2
PacDriveSercos Firmwaree AssistantFirmwarechange of Drives