  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    1/34

    1 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    NetAct Optimizer 3.0 Basic

    Graphical Adjacency Management

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    2/34

    2 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Nokia Siemens Networks

    AcademyLegal notice

    Intellectual Property RightsAll copyrights and intellectual property rights for Nokia Siemens Networks trainingdocumentation, product documentation and slide presentation material, all of which are forthwithknown as Nokia Siemens Networks training material, are the exclusive property of NokiaSiemens Networks. Nokia Siemens Networks owns the rights to copying, modification,translation, adaptation or derivatives including any improvements or developments. NokiaSiemens Networks has the sole right to copy, distribute, amend, modify, develop, license,sublicense, sell, transfer and assign the Nokia Siemens Networks training material. Individuals

    can use the Nokia Siemens Networks training material for their own personal self-developmentonly, those same individuals cannot subsequently pass on that same Intellectual Property toothers without the prior written agreement of Nokia Siemens Networks. The Nokia SiemensNetworks training material cannot be used outside of an agreed Nokia Siemens Networkstraining session for development of groups without the prior written agreement of NokiaSiemens Networks.

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    3/34

    3 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    At the end of this module the trainee should be able to:

    Fix adjacencies with incorrect settings

    Create and modify adjacency template assignment rules

    Create, modify and delete adjacencies and adjacency

    constraints manually using Map, Navigator, and Browser

    Module Objectives

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    4/34

    4 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Graphical Adjacency Management

    How to fix invalid adjacencies?

    How to get correct default values to new adjacencies?

    How to create, delete, and modify adjacencies manually?

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    5/34

    5 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Invalid Adjacencies

    Adjacencies to slave BTS (ADCE and ADJG)Adjacencies where "Target Cell DN" does not match

    with Cell ID and LAC of target GSM cells

    with Cell ID and RNC ID of target WCDMA cellAdjacencies that have no "Target Cell DN" specified

    These should befixed beforecontinuing

    Correction plan iscreated in Optimizer

    Export to CM DB Provision

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    6/34

    6 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Fix Invalid Adjacencies

    See Details

    Select the type(s)

    Click Fix selectedClose

    SelectFile->CM Data Exchange...

    Export automatically createdplan to CM DB

    Provision the plan

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    7/34

    7 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Graphical Adjacency Management

    How to fix invalid adjacencies?

    How to get correct default values to new adjacencies?

    How to create, delete, and modify adjacencies manually?

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    8/34

    8 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Adjacency Templates

    Templates are created and managed in CM Editor

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    9/34

    9 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Adjacency Template Assignments

    Rules have to be created for the template assignment

    Systemtemplate used if no rules or conflicting rules existThe priority of the rules is (in the order of importance)

    assigned cell template name (GSM and WCDMA)

    cell type (GSM)

    frequency band in use (GSM) frequency (WCDMA) * wildcard character (GSM and WCDMA)

    Rules are not user specific

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    10/34

    10 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Template Assignment Rules

    Select a BSC, an RNC, or Common Cluster Assignment Rulesand click Add

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    11/34

    11 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Adjacency type

    Select adjacency type for rule creation

    ADJW used as an example

    Then select source and target categories

    Different possibilities for GSM and WCDMA source and target

    Asterisk (*) is a wild card (any selection)

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    12/34

    12 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Categories for GSM adjacencies

    Select category forsource or target BTSs

    Copy and paste can beused for additionalrules

    BTSs must have the

    template nameassigned for theserules to work

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    13/34

    13 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Categories for WCDMA Adjacencies

    Select category for source or target WCELs

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    14/34

    14 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Template Name for the Rule

    Select a template to be used for a new adjacency that has thespecified categories for source and target cells

    Example: When creating an adjacency from a GSM900 cell to aWCDMA cell with frequency F1, Optimizer automaticallyassigns default values from ADJW template System (External)

    New templates become visible in Optimizer after clicking

    Refresh

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    15/34

    15 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Exercise

    Check the available templates for adjacencies in CM Editor

    You can also create a new template from one of the existingones

    Create one or more rules for BSC or RNC utilising this newtemplate

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    16/34

    16 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Graphical Adjacency Management

    How to fix invalid adjacencies?

    How to get correct default values to new adjacencies?

    How to create, delete, and modify adjacencies manually?

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    17/34

    17 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Viewing Adjacencies

    Locate or select a cell on the map

    Use cell popup menu to show all adjacencies

    Check Default Visibility Settings for the colors

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    18/34

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    19/34

    19 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Visualizing Neighbors

    Select Neighboring cells for Cell Icon visualizationNeighbors are colored with orange

    Neighbors neighbors are colored with yellow

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    20/34

    20 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Cell Labels in GAMCell labels can be used in Graphical Adjacency managementto display the number of outgoing adjacencies for a cell

    Total number or type specific number of outgoing adjacencies

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    21/34

    21 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Adjacency Icons

    To create or delete adjacencies or adjacencyconstraints use icons on the right side ofthe map

    If a plan is not open, Optimizer prompts tocreate or open one

    Create bi-directional adjacency

    Create uni-directional adjacencyCreate bi-directional forbidden constraint

    Create uni-directional forbidden constraint

    Create bi-directional mandatory constraintCreate uni-directional mandatory constraint

    Delete selected adjacency (only active if oneor more adjacencies are selected)

    1.

    2.

    3.

    4.

    5.

    6.

    7.

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    22/34

    22 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Creating Adjacencies, Method 1

    If a plan is not open the user is prompted to open or create oneActivate adjacency creation button on the map toolbar

    Press and hold down the left mousebutton on top of the source cell icon

    Move on top of the target cell iconuntil the icon is selected

    Release the mouse button

    Adjacency line(s) drawnbetween the cells

    It is also possible to createuni-directional adjacenciesto foreign target cells

    Cell labels show if moreadjacencies can be createdfor a cell

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    23/34

    23 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    New Adjacencies

    Adjacency creation is activeuntil selection arrow or a newtool is selected

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    24/34

    24 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Creating Adjacencies, Method 2

    Open the cell pop-up menu and set the cell as a source

    The selected cell icon turns red

    Use mouse (and Ctrl-button) to select one or more cells as targets

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    25/34

    25 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Creating Adjacencies, Method 2

    To clear the source selection use map toolbar button,or select another source cell

    Source cell

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    26/34

    26 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Creating Adjacencies in Navigator

    Select two cells with a mouse and Ctrl-button

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    27/34

    27 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Creating Adjacencies based on Cell Identification

    Tools->Adjacency Optimization->Cell Identification based AdjacencyManagement

    You can also use cell selection popup menu to start thecreation

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    28/34

    28 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Deleting the Selected Adjacencies

    Verify that you have a plan open

    Select one or more adjacencieson the map and use pop-up

    menu or toolbar button to deletethe selected adjacencies

    If the adjacency to be deleted isan actual object it changes color

    or disappears according todefault visibility settings

    If the adjacency to be deleted isa new (created) one it

    disappears (removed from plan)Adjacencies can also be deletedin the Browser and Navigator

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    29/34

    29 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Adjacency Management Matrix

    An easy way of managing intraSITE adjacencies andconstraints

    Also usable for dependenciesbetween selected cells

    Start by selecting a site or

    some cells from the map

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    30/34

    30 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Adjacency Management MatrixFind the source cell from the second column and find targetcell from the same row and click the cell in the crossing

    New adjacencies automatically visible on the Map

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    31/34

    31 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Instant Adjacency Provisioning

    Planned adjacency changes can be provisioned to thenetwork directly from the Browser or from the Map (withsufficient user rights)

    Provisioning is done in the background using

    CM Operations ManagerMore information in the coming module "Provisioning"

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    32/34

    32 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Exercise

    Practise creating new adjacencies in both ways presented!

    Use cell labels to find adjacencies that have a full adjacency list

    How can you verify that the created adjacencies get the correcttemplate?

    Study default visibility settings effect on the adjacency creationand deletion (line color and visibility)

    Use Adjacency Management Matrixto check sites for missing adjacencies

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    33/34

    33 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Summary

    There are six kinds of adjacencies in Optimizer

    ADCE between GSM cells ADJW and ADJG between GSM and WCDMA cells

    ADJD, ADJS and ADJI between WCDMA cellsInvalid adjacencies may not display correctly in Optimizer andshould be fixed before continuing adjacency management oroptimization

    Adjacent cell templates can be created and modified in CMEditor

    Template assignment rules are created in Optimizer

    Adjacencies can be created and deleted on theMap and Navigator

    Adjacency Management Matrix can be used to manageintra site adjacencies Small adjacency plans can be

    provisioned directly from the Browser

  • 7/28/2019 05 Graphical Adjacency Management OPT 3.0

    34/34

    34 Nokia Siemens Networks Presentation / PLe /23.8.2010

    For public use IPR applies

    Document change history

    First draft for Optimizer 3.0PLe1.023.8.2010

    Change commentNameVersionDate