1 g ing informatica8.1.1 installation document dec15
TRANSCRIPT
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
1/13
Setup:
Create the following databases SQL Server
DB Name Size File Properties
Domain 5 MG unrestricted file growth and automaticallygrow file by 10%
RDBU 40 MG unrestricted file growth and automaticallygrow file by 10%
PC_TRAINING 60 MG unrestricted file growth and automaticallygrow file by 10%
Development 50 MG unrestricted file growth and automaticallygrow file by 10%
Create the following Users and assign properties as follows:
User ID Password Default Database PropertiesDomain Domain Domain db_owner
RDBU RDBU RDBU db_owner
SDBU SDBU PC_TRAINING db_owner
TDBU01 TDBU01 PC_TRAINING db_owner
EDW01 EDW01 PC_TRAINING db_owner
DEV_USER DEV_PASS Development db_owner
Step 1: Install PowerCenter Services and Create a Domain
1. Double-click install.exe to begin the installation.
The PowerCenter Installation program Main window appears.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
2/13
2. Click Server to install PowerCenter Services.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
3/13
3. At the Welcome Screen, click Next in the installation program.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
4/13
4. Click Browse to search for the license key file.
Navigate to it and select Open.
5. Click Next in the installation program.
6. The Installation Prerequisites window opens.
Click Next in the installation program.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
5/13
7. The Installation Set window opens. Select Custom.
Click Next in the installation program.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
6/13
8. To install only PowerCenter Services, verify only PowerCenter Services ischecked.
Click Next in the installation program.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
7/13
9. The Installation Directory window opens. Choose the installation directoryusing Browse or accept the default.
Click Next in the installation program.
10. The Pre-Installation Summary window opens.
Confirm that the information is correct, and click Install.The Installation program analyzes the system and then starts copyingPowerCenter files to the hard drive. This may take a few moments.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
8/13
The Create or Join a Domain window opens.
11. Choose Create New Domain, and click Next.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
9/13
Parameter Value
Database type SQL Server
Database URL Locahost:1433
Database User ID Domain
Database User password DomainDatabase Service name Domain
13. Click Test Connection to verify the Installation program can connect to theSQL Server database you specified.
14. Click Next. You should see a popup message that says the test connectionpassed. If you do not, correct the values in the Configure Domain Databasewindow.
15. In the Configure Domain window, enter the following parameters:
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
10/13
Parameter Value
Domain Name Use the default
Domain Host Name localhost
Node Name Use the default
Domain Port Number 6001
Domain User Name admin
Domain Password admin
Confirm Password admin
Create Repository Service Unchecked we will create arepository later
16. Click Next.The Installation program creates the domain configuration in the database youspecified. This may take a few moments. The Configure Informatica Serviceswindow appears. In this window, you can choose whether the Windows servicecalled Informatica Services 8.1.1 uses the local system account to start, or aspecific Windows account you specify here. For this class, you will specify to usethe local system account in the next step.
17. In the Configure Informatica Services window, clear the Install InformaticaServices with a different user account check box.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
11/13
18. Click Next.
The Installation Summary window opens.
The Installation program creates the Windows service for the Service Managerand finishes installing the rest of PowerCenter Services.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
12/13
19. Confirm that you see Installation Status: SUCCESS and click Done.
Step 2: Install the PowerCenter Client
1. Go back to the Installation program Main window that should still be open onyour machine.
2. Click Client to install the PowerCenter Client.
3. Click Next at the Welcome window.
4. On the Installation Set window, choose Custom and click Next.
5. In the PowerCenter Client Components window, clear the Metadata ManagerClient and click Next.
6. Accept the default installation directory and click Next.
7. In the Pre-Installation Summary window, click Install.
The Installation Summary window opens. The Installation program copies filesand installs the PowerCenter Client. This may take a few moments.
8. Confirm that you see Installation Status: SUCCESS and click Next.
-
8/6/2019 1 g Ing Informatica8.1.1 Installation Document Dec15
13/13
9. In the Installation Complete window, do not launch any PowerCenterapplication. Click Done.
10. Go back to the Installation program Main window and click Exit.