14 specification - darkroom dave
Embed Size (px)
TRANSCRIPT

14 SPECIFICATION
MULTIGRADE 5OOH ENLARGER HEAD
Dimensions
Weight
Construction
Electrical cord(integral)
Lamps
Heat filters
Color filters
Cooling fan
Safety features
Light mixing boxes
Height 216mmWidth 316ramDepth 173mm
3kg excluding light mixing box and adaptorkit
Black stoved aluminium alloy sheet andextrusion, with polycarbonate end plates
MulticoreLength 2mMaximum voltage 120Vac
Two 120Vac 300WANSI code ELHQuartz halogen projection lamp withdichroic reflector.
Four 30xl5x2mm heat absorbing glass
Two 25x25xlmm. One blue and one greendichroic interference filter coating onglass substrate. Tempered for maximumstability. Cut-off wavelengths selected togive optimum grade range on ILFORD variablecontrast paper.
115Vac 21W dynamically balancedcentrifugal type. The fan cools both lampand filter assemblies.
Safety cut-out cuts power to lamps underabnormal operating conditions, eg fanfailure.
Micro-switch cuts power to lamps and fanwhen door is opened.
Diffuser type adaptor kitUp to three sizes are supplied to coverthe following negative sizes: up to 35mm,from 35mm to 6x7cm and from 6x7cm to 4x5inches.
Condenser type adaptor kitOne box is supplied. Negative coverage islimited only by your enlarger.
NoteIn all cases, the light mixing box orboxes are supplied with the adaptor kit.
-9

MULTIGRADE 5OOCPM CONTROL UNIT
Dimensions
Weight
Construction
Electrical cord(separate)
Features
Display
Electronics
Additional features
Height 46mmWidth 186mmDepth 192mm
l-2kg
Black stoved aluminium alloy extrusion,with zinc die-cast end plates
MulticoreLength 2m
Listed below. Operation of each is by anilluminated button, except for"expose-cancel" which is a raised bar.Audible confirmation of control operationscan be selected.Exposure time - 0 to 99'9 seconds insteps of O'l seconds.Grade - 0 to 5 in half-grade steps.Memory and Memory clear - for storageof 1 main exposure and up to 8 additionalexposures.BurnBleepPrints counter and Prints clearFocusExpose-cancel
Digital, 7 segment LED
Microprocessor incorporating memory
Sockets for optional exposure probe andfootswitch.Program switch to compensate for lampsthat vary in light intensity.Automatic voltage compensation forvariations in mains voltage up to Z4%.
50

MULTIGRADE SOOS POWER SUPPLY
Dimensions
Weight
Construction
Electrical cord(separate)
Mains input
Replacement fusesMains inputSafelight socket
Outputs
Height 175mmWidth 254mmDepth 140mm
10-3kg
Totally enclosed unit using black stovedaluminium alloy extrusions, with zincdie-cast end plates
3 core, live, neutral and earthLength - 2m
Voltage 120Vac.Frequency 50 or 60Hz (automatic selection),Power consumption 600W maximum.
120V 6-3A SB250V 1A.
Control unitEnlarger head1A supply for local safelight
51

MULTIGRADE 5OOP EXPOSURE PROBE
Dimensions Height 19mmWidth 50mmDepth 155mm
Weight 0-35kg
Construction Black stoved zinc die-casting
Electrical cord Multicore(integral) Length l-2m
Controls Measurement period initiated by pushbutton incorporating LED indication.Ten position calibration knob
Exposure times 1 to 50 seconds (1 second at 20 luxbaseboard illumination)
Repeatability Without safelights, better than ±2%With safelights, typically ±4%
Constant improvements in ILFORD products mean that changes in designor specification may occur from time to time. It will not always bepossible to amend instructions at the same time, and the right toalter the design and specification of the equipment without priornotice is accordingly reserved.
MULTIGRADE 500 is covered by patents and patent applications.
52

Australia Germany United KingdomILFORD PHOTO (Australia) Pty Ltd ILFORD PHOTO GmbH ILFORD PHOTO CompanyPO Box 144 Postfach 124 14-22 Tottenham StreetMtWaverley D-6078 Neu-lsenburg GB-London W1P OAH
3149 \Actoria Holland USABelgium ILFORD PHOTO BV ILFORD PHOTO CorporationSA ILFORD PHOTO NV Jan Rebelstraat 5 West 70 Century RoadKazernenlaan 39 Postbus 9040 PO Box 288B-1040 Brussel NL-1006AA Amsterdam Paramus- , ... New Jersey 07653Canada ItalyILFORD PHOTO (Canada) Limited ILFORD PHOTO SpA If your country is not2751 John Street Origgio (Va) shown here,Markham Casella Postale 77 please contact:Ontario 1-21047 Saronno ILFORD PHOTO InternationalL3R 2Y8 e ILFORD Limited
• h r v T - o AD 14-22 Tottenham StreetDenmark ILFORD PHOTO AB rR , .ILFORD PHOTO A/S Box 3052 GB-LondonGadelandet 18 S-400 10 GoteborgDK-2700Br0nsh0j Switzerland
France ILFORD PHOTO AG/SAILFORD PHOTO SA Rue de Industrie 15BP 336 CH-1700 Fribourg 5Chemin de la FouillouseF-69802 Saint-PriestCedex
Names printed in capitals are ILFORD trade marksILFORD Limited Mobberley CheshirePrinted in England 37104.USA

MEMORY RECORD SHEET
ILFORDMULTIGRADE 5OOCPM
TIME-PRINTS GRADE MEMORY COMMENTS
NEGATIVE REFERENCE ENLARGER APERATURE
FILE NUMBER PRINT SIZE

ILFORD MULTIGRADE 5OO SIMPLIFIED INSTRUCTIONS 50Hz/6C
OPERATING
MULTIGRADE 5OOCPM ILFORD
TIME-PRINTS
c n_/. uGRADE
cA A A BURN A PRINTS
DDDDDDDDDDDD
T T T FOCUS T CLEAR
MEMORY
MEMORY
DDCLEAR
EXPOSE - CANCEL
IL659
MULTIGRADE 5OOCI
TIME-PRINTS
11
A A A BURN
DDDDDDDD
T Y T FOCUS
PM ILF1
GRADE
lie'
A PRINTS
DG• D
T CLEAR
EXPOSE-
»RD
AEMOfiY
MEMORY
DDCLEAR
' ANCt.
11659
Switch on. Ensure typical display. Select contrast (or after operation 5).
MULTIGRADE 5OOCPM ILFORD
TIME -PRINTS
/ V. 5GRADE
B'lA A A BURN A PRINTS
DDDDDDDDDDDD
T T T FOCUS V CLEAR
EXPOSE -
MfMOR
MEMORY
DDCLEAR
CANCEL
IL660ILM*
Locate negative. Select 'focus1 (note 1). Select exposure time (or after operat5).
ion

/60HzIMPORTANT NOTESLight suitable for focusing, compositionand assessment is projected.If the print density is correct but adifferent grade of contrast is required,select the new contrast. It is notnecessary to alter exposure time sincelight intensity is adjustedautomatically across the range ofcontrasts.
nnnnnnnnnnnnnn
Press "expose-cancel" to cancel "focus"
nnnnonnnnnnnnnnD
Expose a sheet by pressing"expose-cancel" (note 2).

ILFORD MULTIGRADE 5OO SIMPLIFIED INSTRUCTIONS 50Hz,
MEMORY
PROGRAMMING
MULTIGRADE 5O<
TIME-PRINTS
L/ 5. uA A A BU
DDDCDDDC
T T T FOC
KPM ILF
GRADE
Cl>'3\N A PRINTS
DDDDDDUS T OEAB
EXPOSE -
ORD
MEMORY
MEMORY
DDCLEAR
CANCEL
IL66S
MULTIGRADE 5OOCPM ILFORDTIME-PRINTS
/ O n!/ u.u\ A A BURN
DDDDDODO
T T T FOCUS
GRADE
5A PRINTS
anan
T CLEAR
EXPOSE -
MEMORY
,£'MEMORY
DDCLEAR
CANCEL
IL659IL003 '"JJ
Select exposure time and grade (note 1). Select exposure time and grade (note 3)
MULTIGRADE 5OOCPM ILFORDTIME-PMNTS
n nu. u
GRADE
nu
A A A BURN A PUNTS
DDDDDDDDDDDD
T T T FOCUS T CLEAR
EXPOSE -
.MtMOR>
,?MEMORY
DDCL£AR
CANCEL
IL666
Press 'memory' (note 2) .

:/60 HzIMPORTANT NOTESMain exposure. This will become memory 'I1Memories '2' to '9' (maximum) foradditional exposures.Repeat operations 2 and 3 until therequired number of memories have beenstored. Return to memory '!' by pressing'memory1 then 'expose-cancel'.Shade paper as required. Repeatoperation 2 until the last of the storedmemories has been run. Two audiblesignals are given and the control unitreturns to memory '!' ready to run thesequence again.
USING
r/iDDDDDDD
nnnnnnn
Expose a sheet by pressing"expose-cancel1.
MULTIGRADE SOIrwt- PRINTS
/ n n1 U.U
A A A H .
DDDCDDDC
T V T FO
|
KPM II
GKADf
5«N A PRINT
D O CDDD:us T CLEAR
EXPOS
.FORD
MEMCFT
,?**MO«Y
IDID
CUM
E -CANCEL
1
IL667
Press 'expose-cancel' to start memory'2' (note 4).

MID-TONE DENSITY
ILFORDMULTIGRADE5OO

MID-TONE DENSITY
ILFORDMULTIGRADE5OO
uO
i
18
CoO
p
I OB
•Oo