AIR CONDITIONERS EL16XC1 ELITE ® Series R-410A Bulletin No. 210758 June 2017 Supersedes April 2017 SEER up to 17.90 1.5 to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh MODEL NUMBER IDENTIFICATION PRODUCT SPECIFICATIONS Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 041 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 060 = 5 tons EL 16 X C 1 - 036 - 230 A 01 Nominal SEER 16 = 16 SEER Refrigerant Type X = R-410A Revision Level Voltage 230 = 208/230V-1 phase-60hz Product Tier EL = Elite ® Series Unit Type C = Air Conditioner (Condenser) Cooling Stages 1 = Single Stage Compressor Ratings Revision Level Regional Standards – (dash) = All Regions or Southwest Region (dependent on size) S = North and South Regions

Upload: ngodat

Post on 15-May-2018

233 views

Category:

Documents


5 download

TRANSCRIPT

Page 1: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

A I R C O N D I T I O N E R S

EL16XC1ELITE® Series

R-410A Bulletin No. 210758

June 2017 Supersedes April 2017

SEER up to 17.901.5 to 5 Tons

Cooling Capacity - 17,800 to 60,000 Btuh

MODEL NUMBER IDENTIFICATION

P R O D U C T S P E C I F I C AT I O N S

Nominal Cooling Capacity 018 = 1.5 tons 024 = 2 tons 030 = 2.5 tons 036 = 3 tons 041 = 3.5 tons 042 = 3.5 tons 047 = 4 tons 048 = 4 tons 060 = 5 tons

EL 16 X C 1 - 036 - 230 A 01

Nominal SEER 16 = 16 SEER

Refrigerant Type X = R-410A

Revision Level

Voltage 230 = 208/230V-1 phase-60hz

Product Tier EL = Elite® Series

Unit Type C = Air Conditioner (Condenser)

Cooling Stages 1 = Single Stage Compressor

Ratings Revision Level

EL16XC1 - 1.5-5 TON AIR CONDITIONERS

Regional Standards– (dash) = All Regions or Southwest Region (dependent on size)

S = North and South Regions

Page 2: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 2

WARRANTY

Compressor - limited warranty for ten years in residential installations and five years in non-residential installations.

All other covered components - five years in residential installations and one year in non-residential installations.

Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details.

APPROVALSAHRI Certified to AHRI Standard 210/240-2008.Sound rated in Lennox reverberant sound test room in accordance with test conditions included in AHRI Standard 270-2008.Tested in the Lennox Research Laboratory environmental test room.Rated according to U.S. Department of Energy (DOE) test procedures.Region specific models meet the minimum efficiency requirements for U.S DOE Federal Regional Standards in that area.Air conditioners and components within bonded for grounding to meet safety standards for servicing required by UL and CEC.Units are ETL certified for the U.S. and Canada.ISO 9001 Registered Manufacturing Quality System.For expanded ratings, see www.LennoxPros.com.Certain EnErgy Star® certified units are designed to use less energy, help save money on utility bills, and help protect the environment.

A

APPLICATIONSSEER up to 17.90. 1.5 through 5 ton.Single-phase power supply.Vertical air discharge allows concealment behind shrubs at grade level or out of sight on a roof.Matching add-on furnace indoor coils or air handlers provide a wide range of cooling capacities and applications. See AHRI Ratings table. See Indoor Coils and Air Handlers sections for data.Units shipped completely factory assembled, piped and wired.Each unit test operated at the factory ensuring proper operation. Installer must set air conditioner, connect refrigerant lines and make electrical connections to complete job.

B

C

D

E

F

G

H

I

FEATURES

CONTENTSAHRI System Matches - All Regions ......................... 11AHRI System Matches - North / South Regions ........ 91AHRI System Matches - Southwest Region ............ 114Dimensions - Unit ........................................................ 9Electrical Data.............................................................. 6Features....................................................................... 2Field Wiring .................................................................. 8Installation Clearances ................................................ 8Model Number Identification ........................................ 1Optional Accessories ................................................... 6Outdoor Sound Data .................................................... 8Specifications............................................................... 6

Page 3: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 3

REFRIGERATION SYSTEMR-410A Refrigerant Non-chlorine, ozone friendly, R-410A. Unit pre-charged with refrigerant. See Specification table.

Outdoor Coil Fan Direct drive fan moves large air volumes uniformly through entire condenser coil for high refrigerant cooling capacity.Vertical air discharge minimizes operating sounds and eliminates damage to lawn and shrubs.Fan motor has sleeve bearings and is inherently protected.Motor totally enclosed for maximum protection from weather, dust and corrosion.Fan guard constructed of corrosion-resistant PVC (polyvinyl chloride) coated steel.Fan service access accomplished by removal of fan guard.

Lennox Quantum™ CoilEnhanced aluminum alloy tube/enhanced fin coil for superior corrosion resistance.Lennox designed and fabricated coil.Ripple-edged aluminum fins.Aluminum tube construction.Lanced fins provide maximum exposure of fin surface to air stream resulting in excellent heat transfer.Fin collars grip tubing for maximum contact area.Flared shoulder tubing connections.Coil is factory tested under high pressure to insure leakproof construction.Entire coil is accessible for cleaning.High Capacity Liquid Line Drier Approved for use with R-410A systems.Traps any moisture or dirt that could contaminate the refrigerant system.

High Pressure SwitchShuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting.Protects compressor from excessive condensing pressure.Auto-reset.

Discharge ThermostatFactory installed on the discharge line of the compressor. SPST, auto-resetRemoves power from the compressor when discharge temperature exceeds the factory setting of 220ºF.

B

C

D

E

Refrigerant Flow ControlUnits applicable to expansion valve systems or RFC systems when matched with specific indoor coils.

RFCIV:Accurately meters refrigerant in system.Refrigerant control is accomplished by exact sizing of refrigerant metering orifice.The principle involves matching indoor coil with proper bore size of orifice in metering device.Equalizes pressure shortly after compressor stops, unit starts unloaded, eliminating need for additional controls.Furnished with air conditioner.

Optional Accessories

Expansion Valve Kits Must be ordered extra and field installed on certain indoor units.See TXV/Orifice Usage table.Chatleff-style fittings.

Freezestat Installs on or near the vapor line of the indoor coil or on the suction line.Senses suction line temperature and cycles the compressor off when suction line temperature falls below it’s setpoint.Opens at 29°F and closes at 58°F.

Loss of Charge Switch Kit Helps protect the compressor from damage due low refrigerant charge conditions.SPST, normally-closed switch, automatic reset switch mounted on suction line.

Refrigerant Line Kits Refrigerant lines (suction & liquid) are shipped refrigeration clean.Lines are cleaned, dried, pressurized and sealed at factory.Suction line fully insulated.Lines are stubbed at both ends.Not available for -060 models and must be field fabricated.

O−RING

RFCIV METERING SYSTEMRFCIV

ORIFICE

ORIFICE BODY(On Coil)

SEALNUT SWEAT

CONNECTION

LIQUIDLINE

LIQUIDLINE SCREEN

FEATURES

Page 4: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 4

COMPRESSORScroll Compressor Compressor features high efficiency with uniform suction flow, constant discharge flow, high volumetric efficiency and quiet operation.Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them.During compression, one scroll remains stationary while the other scroll orbits around it.Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates.As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced.When the pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls.During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle.Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency.Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to be worked toward the center and discharged.Low gas pulses during compression reduces operational sound levels.Compressor motor is internally protected from excessive current and temperature.Compressor is installed in the unit on specially formulated, resilient rubber base for improved sound dampening and vibration-free operation resulting in quieter operating sound levels. See Outdoor Sound Data table for details.

Compressor Crankcase Heater (060 Models) Protects against refrigerant migration that can occur during low ambient operation.Factory Installed.

Compressor Sound Dampening System A polyethylene compressor cover containing a 2 inch thick batt of fiberglass insulation for better sound dampening.All open edges are sealed with a one-inch wide hook and loop fastening tape.

F Optional Accessories

Compressor Crankcase Heater (018 thru 048 models) Protects against refrigerant migration that can occur during low ambient operation.

Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally doesn’t need a potential relay and start capacitor.In conditions such as low voltage, this kit may be required to increase the compressor starting torque.

Compressor Low Ambient Cut-Off SwitchNon-adjustable switch (low ambient cut-out) prevents compressor operation when outdoor temperature is below 35°F.

CONTROLS

Optional Accessories

Indoor Blower Off Delay Relay Delays the indoor blower-off time during the cooling cycle.See AHRI System Matches for usage.

Low Ambient Kit Air conditioners operate satisfactorily down to 45°F outdoor air temperature without any additional controls.Low Ambient Control Kit can be field installed, allowing unit operation down to 30°F.Crankcase heater and freezestat should be installed on compressors equipped with a Low Ambient Kit.A compressor lock-out thermostat should be added to terminate compressor operation below recommended operation conditions

Thermostat Thermostat not furnished with unit. See Thermostat bulletins in Controls Section and Lennox Price Book.

Compressor Timed-Off Control Kit prevents compressor short-cycling and allows time for suction and discharge pressure to equalize.Permits compressor start-up in an unloaded condition. Automatic reset with 5 minute delay between compressor shut-off and start-up.

FEATURES

Page 5: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 5

CABINET

Heavy-gauge steel constructionPre-painted cabinet finish.Control box is conveniently located with all controls factory wired.Corner patch plate allows access to compressor components.Drainage holes are provided in base section for moisture removal.High density polyethylene unit support feet raise the unit off of the mounting surface, away from damaging moisture.

PermaGuard™ Unit BaseDurable zinc-coated base section resists rust and corrosion.

SmartHinge™ Louvered Coil Protection Steel louvered panels provides complete coil protection.Panels are hinged to allow easy cleaning and servicing of coils.Panels may be completely removed. Interlocking tabs and slots assure tight fit on cabinet.

Refrigerant Line Connections, Electrical Inlets and Service Valves Suction and liquid lines are located on corner of unit cabinet and are made with sweat connections.See dimension drawing.Fully serviceable brass service valves prevent corrosion and provide access to refrigerant system. Suction valve can be fully shut off, while liquid valve may be front seated to manage refrigerant charge while servicing system.Refrigerant line connections and field wiring inlets are located in one central area of the cabinet.See dimension drawing.

G

H

I

FEATURES

Page 6: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 6

SPECIFICATIONSGeneral Data

Model No. All Regions EL16XC1-018 EL16XC1-024 EL16XC1-030 - - -North / South Regions - - - - - - - - - EL16XC1S036

Southwest Region - - - - - - - - - EL16XC1-036Nominal Tonnage 1.5 2 2.5 3

Connections (sweat)

Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8Suction line (o.d.) - in. 3/4 3/4 3/4 7/8

Refrigerant 1 R-410A charge furnished 4 lbs. 9 oz. 4 lbs. 9 oz. 5 lbs. 8 oz. 7 lbs. 1 oz.Outdoor Coil

Net face area - sq. ft. Outer coil 13.22 16.33 21.00 16.33Inner coil - - - - - - - - - 15.75

Tube diameter - in. 5/16 5/16 5/16 5/16No. of rows 1 1 1 2

Fins per inch 26 26 26 22Outdoor Fan

Diameter - in. 18 22 22 22No. of blades 3 3 3 3

Motor hp 1/10 1/6 1/6 1/6Cfm 2290 3160 3160 3160

Rpm 1075 825 825 825Watts 160 215 215 190

Shipping Data - lbs. 1 pkg. 155 171 187 205

ELECTRICAL DATALine voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph2 Maximum overcurrent protection (amps) 20 25 25 303 Minimum circuit ampacity 11.9 14.6 17 18.0Compressor Rated load amps 9.0 10.9 12.8 13.6

Locked rotor amps 48 59.3 67.8 79Power factor 0.97 0.97 0.97 0.96

Outdoor Fan Motor Full load amps 0.7 1 1 1Locked rotor amps 1.3 1.9 1.9 1.9

OPTIONAL ACCESSORIES - ORDER SEPARATELYCompressor Crankcase Heater 93M04 • • • •Compressor Hard Start Kit

Copeland 10J42 • • •LG 88M91 • • • •

Compressor Low Ambient Cut-Off Switch 45F08 • • • •Compressor Timed-Off Control 47J35 • • • •Freezestat 3/8 in. tubing 93G35 • • • •

5/8 in. tubing 50A93 • • • •Indoor Blower Off Delay Relay 58M81 • • • •Loss of Charge Switch Kit 84M23 • • • •4 Low Ambient Kit (Fan Cycling) 34M72 • • • •Refrigerant Line Sets

L15-41-20 L15-41-30

L15-41-40 L15-41-50

• • •

L15-65-30 L15-65-40 L15-65-50

NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and

additional refrigerant charge required.2 HACR type breaker or fuse.3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit.

Page 7: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 7

SPECIFICATIONSGeneral Data

Model No. All Regions EL16XC1-041 EL16XC1-042 EL16XC1-047 EL16XC1-048 EL16XC1-060Nominal Tonnage 3.5 3.5 4 4 5

Connections (sweat)

Liquid line (o.d.) - in. 3/8 3/8 3/8 3/8 3/8Suction line (o.d.) - in. 7/8 7/8 7/8 7/8 1-1/8

Refrigerant 1 R-410A charge furnished 9 lbs. 9 oz. 8 lbs. 12 oz. 11 lbs. 0 oz. 9 lbs. 12 oz. 12 lbs. 0 oz.Outdoor Coil

Net face area - sq. ft. Outer coil 21.00 21.00 22.17 21.00 29.09Inner coil 20.25 20.25 21.33 20.25 28.16

Tube diameter - in. 5/16 5/16 5/16 5/16 5/16No. of rows 2 2 2 2 2

Fins per inch 22 22 22 22 22Outdoor Fan

Diameter - in. 22 22 26 22 26No. of blades 3 3 4 4 3

Motor hp 1/6 1/6 1/3 ¼ 1/3Cfm 3050 3050 4400 3600 4550

Rpm 825 825 825 825 825Watts 190 190 310 310 310

Shipping Data - lbs. 1 pkg. 227 234 272 255 284

ELECTRICAL DATALine voltage data - 60hz 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph 208/230V-1ph2 Maximum overcurrent protection (amps) 30 40 35 40 503 Minimum circuit ampacity 19.3 23.4 21.9 24.2 29.6Compressor Rated load amps 14.7 17.9 16.1 18.0 22.2

Locked rotor amps 75 112 105.5 117 127.9Power factor 0.96 0.96 0.98 0.96 0.98

Outdoor Fan Motor Full load amps 1 1 1.8 1.7 1.8Locked rotor amps 1.9 1.9 2.9 3.2 2.9

OPTIONAL ACCESSORIES - ORDER SEPARATELYCompressor Crankcase Heater 93M04 • •

93M06 • •

Factory •

Compressor Hard Start Kit

Copeland 10J42 • •LG 88M91 • • • • •

Compressor Low Ambient Cut-Off Switch 45F08 • • • • •Compressor Timed-Off Control 47J35 • • • • •Freezestat 3/8 in. tubing 93G35 • • • • •

5/8 in. tubing 50A93 • • • • •Indoor Blower Off Delay Relay 58M81 • • • • •Loss of Charge Switch Kit 84M23 • • • • •4 Low Ambient Kit (Fan Cycling) 34M72 • • • • •Refrigerant Line Sets

L15-65-30 L15-65-40L15-65-50

• • • •

Field Fabricate •NOTE - Extremes of operating range are plus 10% and minus 5% of line voltage.1 Refrigerant charge sufficient for 15 ft. length of refrigerant lines. For longer line set requirements see the Installation Instructions for information about line set length and

additional refrigerant charge required.2 HACR type breaker or fuse.3 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements.4 Crankcase Heater and Freezestat are recommended with Low Ambient Kit.

Page 8: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 8

OUTDOOR SOUND DATA

1 Unit Model No.

Octave Band Linear Sound Power Levels dB, re 10-12 Watts 1Sound Rating

Number (dB)

Center Frequency - HZ

125 250 500 1000 2000 4000 8000

EL16XC1-018 55 61 67 68 63.5 59 50.5 72EL16XC1-024 55 62 67.5 66.5 63 59 52.5 72EL16XC1-030 54 61.5 66 66 62 57 51 71EL16XC1-036 / EL16XC1S036 56 66 69 67 62.5 57.5 50.5 73

EL16XC1-041 54.5 62.5 67.5 67 62.5 58.5 52.5 72EL16XC1-042 55.5 62.5 68 67 62 57.5 51.5 72EL16XC1-047 55 62 67 66.5 62.5 57.5 49.5 72EL16XC1-048 55.5 64.5 70 71 65 60.5 54 75EL16XC1-060 55.5 62.5 67 66.5 62.5 60 53.5 73

NOTE - the octave sound power data does not include tonal correction.1 Tested according to AHRI Standard 270-2008 test conditions.

FIELD WIRING

B

DISCONNECTSWITCH

(By Others)

LENNOXAIR

CONDITIONER

LENNOXHEATING UNIT

ORAIR HANDLER

UNIT

DISCONNECTSWITCH

(By Others)THERMOSTAT

(Optional)

C

DA

INSTALLATION CLEARANCES - INCHES (MM)

A - Two Wire Power (not furnished)B - Two Power (not furnished). See Electrical DataC - Four Wire Low Voltage (not furnished). 18 ga. minimumD - Five Wire Low Voltage (not furnished). 18 ga. minimumAll wiring must conform to NEC or CEC and local electrical codes.

SeeNOTES

See NOTES NOTES:Service clearance of 30 in. (762 mm) must be maintained on oneof the sides adjacent to the control box.

Clearance to one of the other three sides must be 36 in. (914 mm)

Clearance to one of the remaining two sides may be 12 in. (305mm) and the final side may be 6 in. (152 mm).

A clearance of 24 in. (610 mm) must be maintained between twounits.

48 in. (1219 mm) clearance required on top of unit.

SeeNOTES

See NOTES ControlBox

Page 9: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 9

UNIT SUPPORTFEET

8−1/2(216)

EL16XC1-018 BASE SECTION(Small Base)

8−3/4(222)

5−1/2(140)

9−1/2(241)

8−1/4(210)

13−1/2(343)

ELECTRICALINLETS

SIDE VIEW

DISCHARGE AIR

SUCTION LINECONNECTION

LIQUID LINECONNECTION

A

BC

4−1/4(108)4−3/4(121)

1 (25)

2 (51)

END VIEW

TOP VIEW

SUCTION LINECONNECTION

LIQUID LINECONNECTION

UNIT SUPPORTFEET

EL16XC1-024 TO -060 BASE SECTION(Medium and Large Base)

D K

GF

EJ

H

DIMENSIONS - UNIT - INCHES (MM)

Model No.A B C D E F G H J K

in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mmEL16XC1-018 31 787 27 686 28 711 - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -EL16XC1-024 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524EL16XC1-030 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524EL16XC1-036 / EL16XC1S036 31 787 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524

EL16XC1-041 35 889 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524EL16XC1-042 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524EL16XC1-047 35 889 35-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683EL16XC1-048 39 991 30-1/2 775 35 889 13-7/8 352 7-3/4 197 3-1/4 83 27-1/8 689 3-5/8 92 4-1/2 114 20-5/8 524EL16XC1-060 45 1143 35-1/2 902 39-1/21003 16-7/8 429 8-3/4 222 3-1/8 79 30-3/4 781 4-5/8 117 3-3/4 95 26-7/8 683

Page 10: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 10

TXV/ORIFICE USAGEUse this table for C33, CH23, CH33, CH35 and CR33 Field Installed TXV/Orifice Match-Ups.Model No. Refrigerant Metering

Orifice (RFC)Thermal Expansion Valve (TXV)Order No. Orifice Size

EL16XC1-018 97M74 0.053 12J18EL16XC1-024 97M75 0.057 12J18EL16XC1-030 10W99 0.065 12J18EL16XC1-036 EL16XC1S036

11W02 0.073 12J19

EL16XC1-041 97M77 0.074 12J20EL16XC1-042 97M78 0.076 12J20EL16XC1-047 10W86 0.080 12J20EL16XC1-048 11W07 0.083 12J20EL16XC1-060 11W11 0.093 12J20CX34 upflow coils and all Lennox air handlers are shipped with a factory installed TXV. In most cases, no change out of the valve is needed.If a change out is required it will be listed in the “TXV SUBSTITUTIONS” table. The correct TXV must be ordered separately and field installed.C33 and CH33 coils - Use the orifice shipped with the outdoor unit or replace the factory installed orifice with the expansion valve listed.CR33 and CH23 coils - Use the orifice shipped with the outdoor unit or use the expansion valve listed.CH35 coils - Factory installed orifice must be replaced with the expansion valve listed.

MOST POPULAR MATCHESOutdoor Unit Model No.

Indoor Unit Model No

EL16XC1-018 CX34-25EL16XC1-024 CX34-25EL16XC1-030 CX34-31EL16XC1-036 EL16XC1S036 CX34-38

EL16XC1-041 CX34-49EL16XC1-042 CX34-49EL16XC1-047 CX34-62CEL16XC1-048 CX34-62CEL16XC1-060 CX34-62C

AHRI STANDARD 210/240

Cooling or heating capacities are net values, including the effects of blower motor heat, and do not include supplementary heat. Power input is the total power input to the compressor(s) and fan(s), plus any controls and other items required as part of the system for normal operation.

Units which do not have an indoor air-circulating blower furnished as part of the model, i.e., split system with indoor coil only, is established by subtracting from the total cooling capacity 1250 Btu/h per 1,000 cfm, and by adding the same amount to the heating capacity. Total power input for both heating and cooling is increased by 365 W per 1,000 cfm of indoor air circulated.

*TXV SUBSTITUTIONSUse this table to determine if the factory installed TXV in the indoor unit needs to be replaced.

Model Indoor Coil or Air Handler

Factory TXV

Replacement TXV

030 CX34-42 21J20 21J18

030 CX34-43 21J20 21J18

030 CX34/CX35-48 21J20 21J18* CX34 coils and all air handlers - The factory installed expansion valve must be replaced with the expansion valve listed (ordered separately). If the combination is not listed above, the factory installed TXV is used.

Page 11: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 11

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-018-230A RFC 18,000 14 12.2 C35-30B 8809086EL16XC1-018-230A RFC 18,000 14.25 12.2 CH33-31A 8809116EL16XC1-018-230A RFC 18,000 14 12.2 CH33-31B 8809125EL16XC1-018-230A RFC 18,000 14 12.2 CR33-30/36A 8809158EL16XC1-018-230A RFC 18,000 14 12.2 CR33-30/36B 8809163EL16XC1-018-230A TXV 17,800 14.5 12.5 C33-18 EL180UH045E36A 8809014EL16XC1-018-230A TXV 17,800 14.5 12.5 C33-18 EL180UH045XE36A 8809013EL16XC1-018-230A TXV 18,000 16 13 C33-19 EL180UH045E36A 8809016EL16XC1-018-230A TXV 18,000 16 13 C33-19 EL180UH045XE36A 8809015EL16XC1-018-230A TXV 17,900 14.5 12.5 C33-24A EL180UH045E36A 8809019EL16XC1-018-230A TXV 17,900 14.5 12.5 C33-24A EL180UH045XE36A 8809017EL16XC1-018-230A TXV 18,000 14.5 12.2 C33-24B EL180UH070E36B 8809023EL16XC1-018-230A TXV 18,000 14.5 12.2 C33-24B EL180UH070XE36B 8809022EL16XC1-018-230A TXV 18,400 15.1 12.5 C33-24B EL195UH030XE24B 8809020EL16XC1-018-230A TXV 18,400 15.1 12.5 C33-24B EL195UH045XE24B 8809021EL16XC1-018-230A TXV 18,000 14.5 12.2 C33-24B EL195UH045XE36B 8809024EL16XC1-018-230A TXV 18,000 14.5 12.2 C33-24B EL296UH045XE36B 8809025EL16XC1-018-230A TXV 18,000 16 13 C33-25A EL180UH045E36A 8809028EL16XC1-018-230A TXV 18,000 16 13 C33-25A EL180UH045XE36A 8809026EL16XC1-018-230A TXV 18,000 14.25 12.2 C33-25A 8809029EL16XC1-018-230A TXV 18,000 15.5 12.5 C33-25B EL180UH070E36B 8809030EL16XC1-018-230A TXV 18,000 15.5 12.5 C33-25B EL180UH070XE36B 8809031EL16XC1-018-230A TXV 19,400 16 13 C33-25B EL195UH030XE24B 8809032EL16XC1-018-230A TXV 19,400 16 13 C33-25B EL195UH045XE24B 8809033EL16XC1-018-230A TXV 19,400 16 13 C33-25B EL195UH045XE36B 8809034EL16XC1-018-230A TXV 19,000 16 13 C33-25B EL296UH045XE36B 8809035EL16XC1-018-230A TXV 19,400 16 13 C33-25B EL296UH045XV36B 8809036EL16XC1-018-230A TXV 19,000 16 13 C33-25B EL296UH070XV36B 8809038EL16XC1-018-230A TXV 19,000 16 13 C33-25B SLP98UH070XV36B 8809039EL16XC1-018-230A TXV 18,000 14.25 12.2 C33-25B 8809040EL16XC1-018-230A TXV 18,000 15.5 12.5 C33-30A EL180UH045E36A 8809041EL16XC1-018-230A TXV 18,000 15.5 12.5 C33-30A EL180UH045XE36A 8809042EL16XC1-018-230A TXV 18,000 14.5 12.5 C33-30B EL180UH070E36B 8809045EL16XC1-018-230A TXV 18,000 14.5 12.5 C33-30B EL180UH070XE36B 8809046EL16XC1-018-230A TXV 18,900 15.5 12.5 C33-30B EL195UH030XE24B 8809043EL16XC1-018-230A TXV 18,900 15.5 12.5 C33-30B EL195UH045XE24B 8809044EL16XC1-018-230A TXV 18,000 15.1 12.5 C33-30B EL195UH045XE36B 8809047EL16XC1-018-230A TXV 18,000 15.1 12.5 C33-30B EL296UH045XE36B 8809049EL16XC1-018-230A TXV 18,000 16 13 C33-31A EL180UH045E36A 8809050EL16XC1-018-230A TXV 18,000 16 13 C33-31A EL180UH045XE36A 8809051EL16XC1-018-230A TXV 18,000 14.5 12.2 C33-31A 8809052EL16XC1-018-230A TXV 18,000 15.5 13 C33-31B EL180UH070E36B 8809053EL16XC1-018-230A TXV 18,000 15.5 13 C33-31B EL180UH070XE36B 8809054EL16XC1-018-230A TXV 20,000 16 13.5 C33-31B EL195UH030XE24B 8809055EL16XC1-018-230A TXV 20,000 16 13.5 C33-31B EL195UH045XE24B 8809056EL16XC1-018-230A TXV 18,000 16 13 C33-31B EL195UH045XE36B 8809057EL16XC1-018-230A TXV 18,000 16 13 C33-31B EL296UH045XE36B 8809058EL16XC1-018-230A TXV 20,000 16 13.5 C33-31B EL296UH045XV36B 8809059EL16XC1-018-230A TXV 19,600 17 13.5 C33-31B EL296UH070XV36B 8809060NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 12: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 12

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-018-230A TXV 19,600 17 13.5 C33-31B SLP98UH070XV36B 8809061EL16XC1-018-230A TXV 18,000 14.5 12.2 C33-31B 8809062EL16XC1-018-230A TXV 18,000 16 13 C35-24A EL180UH045E36A 8809063EL16XC1-018-230A TXV 18,000 16 13 C35-24A EL180UH045XE36A 8809064EL16XC1-018-230A TXV 18,000 15.5 12.5 C35-24B EL180UH070E36B 8809067EL16XC1-018-230A TXV 18,000 15.5 12.5 C35-24B EL180UH070XE36B 8809068EL16XC1-018-230A TXV 19,600 16 13 C35-24B EL195UH030XE24B 8809065EL16XC1-018-230A TXV 19,600 16 13 C35-24B EL195UH045XE24B 8809066EL16XC1-018-230A TXV 19,600 16 13 C35-24B EL195UH045XE36B 8809069EL16XC1-018-230A TXV 19,600 16 13 C35-24B EL296UH045XE36B 8809070EL16XC1-018-230A TXV 19,600 16 13 C35-24B EL296UH045XV36B 8809071EL16XC1-018-230A TXV 19,600 16 13 C35-24B EL296UH070XV36B 8809072EL16XC1-018-230A TXV 19,600 16 13 C35-24B SLP98UH070XV36B 8809073EL16XC1-018-230A TXV 18,000 16 13 C35-30A EL180UH045E36A 8809074EL16XC1-018-230A TXV 18,000 16 13 C35-30A EL180UH045XE36A 8809075EL16XC1-018-230A TXV 18,000 14.5 12.2 C35-30A 8809076EL16XC1-018-230A TXV 18,000 15.5 13 C35-30B EL180UH070E36B 8809079EL16XC1-018-230A TXV 18,000 15.5 13 C35-30B EL180UH070XE36B 8809080EL16XC1-018-230A TXV 20,000 16 13.5 C35-30B EL195UH030XE24B 8809077EL16XC1-018-230A TXV 20,000 16 13.5 C35-30B EL195UH045XE24B 8809078EL16XC1-018-230A TXV 18,000 16 13 C35-30B EL195UH045XE36B 8809081EL16XC1-018-230A TXV 18,000 16 13 C35-30B EL296UH045XE36B 8809082EL16XC1-018-230A TXV 20,000 16 13.5 C35-30B EL296UH045XV36B 8809083EL16XC1-018-230A TXV 20,000 17 13.5 C35-30B EL296UH070XV36B 8809084EL16XC1-018-230A TXV 20,000 17 13.5 C35-30B SLP98UH070XV36B 8809085EL16XC1-018-230A TXV 18,000 14.5 12.2 C35-30B 8809087EL16XC1-018-230A TXV 18,000 16 13 CBA27UHE-018 10259401EL16XC1-018-230A TXV 18,000 16 13 CBA27UHE-024 10259402EL16XC1-018-230A TXV 18,000 15.5 12.5 CBX25UHV-018 8809088EL16XC1-018-230A TXV 18,000 16 13 CBX25UHV-024 8809089EL16XC1-018-230A TXV 18,000 16 13 CBX27UH-018 8809090EL16XC1-018-230A TXV 18,000 16 13 CBX27UH-024 8809091EL16XC1-018-230A TXV 18,000 14.5 12.2 CBX32M-018/024 8809092EL16XC1-018-230A TXV 18,000 14.5 12.5 CBX32M-030 8809093EL16XC1-018-230A TXV 18,000 16 13 CBX32MV-018/024 8809094EL16XC1-018-230A TXV 18,000 16 13 CBX32MV-024/030 8809095EL16XC1-018-230A TXV 18,000 16 13 CBX40UHV-024 8809096EL16XC1-018-230A TXV 18,000 16 13 CBX40UHV-030 8809097EL16XC1-018-230A TXV 17,800 14.5 12.5 CH23-21 EL180UH045E36A 10260328EL16XC1-018-230A TXV 18,000 16 13 CH33-19 EL180UH045E36A 8809098EL16XC1-018-230A TXV 18,000 16 13 CH33-19 EL180UH045XE36A 8809099EL16XC1-018-230A TXV 18,000 15.5 12.5 CH33-24/30 EL180UH045E36A 8809100EL16XC1-018-230A TXV 18,000 15.5 12.5 CH33-24/30 EL180UH045XE36A 8809102EL16XC1-018-230A TXV 18,000 16 13 CH33-25A EL180UH045E36A 8809103EL16XC1-018-230A TXV 18,000 16 13 CH33-25A EL180UH045XE36A 8809104EL16XC1-018-230A TXV 18,000 15.5 12.5 CH33-25B EL180UH070E36B 8809105EL16XC1-018-230A TXV 18,000 15.5 12.5 CH33-25B EL180UH070XE36B 8809106EL16XC1-018-230A TXV 19,800 16 13 CH33-25B EL195UH0430XE24B 8809107EL16XC1-018-230A TXV 19,800 16 13 CH33-25B EL195UH045XE24B 8809109NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 13: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 13

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-018-230A TXV 19,400 16 13 CH33-25B EL195UH045XE36B 8809110EL16XC1-018-230A TXV 19,400 16 13 CH33-25B EL296UH045XE36B 8809111EL16XC1-018-230A TXV 19,400 16 13 CH33-25B EL296UH045XV36B 8809112EL16XC1-018-230A TXV 18,000 16 13 CH33-31A EL180UH045E36A 8809113EL16XC1-018-230A TXV 18,000 16 13 CH33-31A EL180UH045XE36A 8809114EL16XC1-018-230A TXV 18,000 14.5 12.2 CH33-31A 8809117EL16XC1-018-230A TXV 18,000 16 13 CH33-31B EL180UH070E36B 8809118EL16XC1-018-230A TXV 18,000 16 13 CH33-31B EL180UH070XE36B 8809119EL16XC1-018-230A TXV 20,000 16 13.5 CH33-31B EL195UH030XE24B 8809120EL16XC1-018-230A TXV 20,000 16 13.5 CH33-31B EL195UH045XE24B 8809121EL16XC1-018-230A TXV 18,000 16 13 CH33-31B EL195UH045XE36B 8809122EL16XC1-018-230A TXV 18,000 16 13 CH33-31B EL296UH045XE36B 8809123EL16XC1-018-230A TXV 20,000 17 13.5 CH33-31B EL296UH045XV36B 8809124EL16XC1-018-230A TXV 18,000 14.5 12.2 CH33-31B 8809126EL16XC1-018-230A TXV 18,000 16 13 CH35-18A EL180UH045E36A 8809127EL16XC1-018-230A TXV 18,000 16 13 CH35-18A EL180UH045XE36A 8809128EL16XC1-018-230A TXV 18,000 16 13 CH35-24A EL180UH045E36A 8809129EL16XC1-018-230A TXV 18,000 16 13 CH35-24A EL180UH045XE36A 8809130EL16XC1-018-230A TXV 18,000 15.5 12.5 CH35-24B EL180UH070E36B 8809131EL16XC1-018-230A TXV 18,000 15.5 12.5 CH35-24B EL180UH070XE36B 8809132EL16XC1-018-230A TXV 19,800 16 13 CH35-24B EL195UH030XE24B 8809133EL16XC1-018-230A TXV 19,800 16 13 CH35-24B EL195UH045XE24B 8809135EL16XC1-018-230A TXV 18,000 15.5 12.5 CH35-24B EL195UH045XE36B 8809136EL16XC1-018-230A TXV 18,000 15.5 12.5 CH35-24B EL296UH045XE36B 8809137EL16XC1-018-230A TXV 19,600 16 13 CH35-24B EL296UH045XV36B 8809138EL16XC1-018-230A TXV 18,000 16 13 CH35-30A EL180UH045E36A 8809139EL16XC1-018-230A TXV 18,000 16 13 CH35-30A EL180UH045XE36A 8809140EL16XC1-018-230A TXV 18,000 14.5 12.2 CH35-30A 8809141EL16XC1-018-230A TXV 18,000 16 13 CH35-30B EL180UH070E36B 8809142EL16XC1-018-230A TXV 18,000 16 13 CH35-30B EL180UH070XE36B 8809143EL16XC1-018-230A TXV 20,000 16 13.5 CH35-30B EL195UH030XE24B 8809145EL16XC1-018-230A TXV 20,000 16 13.5 CH35-30B EL195UH045XE24B 8809146EL16XC1-018-230A TXV 18,000 16 13 CH35-30B EL195UH045XE36B 8809147EL16XC1-018-230A TXV 18,000 16 13 CH35-30B EL296UH045XE36B 8809148EL16XC1-018-230A TXV 19,600 17 13.5 CH35-30B EL296UH045XV36B 8809149EL16XC1-018-230A TXV 18,000 14.5 12.2 CH35-30B 8809150EL16XC1-018-230A TXV 18,000 15.5 12.5 CR33-18 EL180DF045E36A 8809151EL16XC1-018-230A TXV 18,000 15.1 12.5 CR33-24A EL180DF045E36A 8809152EL16XC1-018-230A TXV 18,000 14.5 12.5 CR33-24B EL180DF070E36B 8809154EL16XC1-018-230A TXV 18,000 14.5 12.2 CR33-24B EL195DF045XE36B 8809155EL16XC1-018-230A TXV 18,000 14.5 12.2 CR33-24B EL195DF070XE36B 8809156EL16XC1-018-230A TXV 18,000 16 13 CR33-30/36A EL180DF045E36A 8809157EL16XC1-018-230A TXV 18,000 14.5 12.2 CR33-30/36A 8809159EL16XC1-018-230A TXV 18,000 15.5 13 CR33-30/36B EL180DF070E36B 8809160EL16XC1-018-230A TXV 18,000 15.5 12.5 CR33-30/36B EL195DF045XE36B 8809161EL16XC1-018-230A TXV 18,000 15.5 12.5 CR33-30/36B EL195DF070XE36B 8809162EL16XC1-018-230A TXV 18,000 14.5 12.2 CR33-30/36B 8809165EL16XC1-018-230A TXV 17,900 14.5 12.5 CX34-18/24A EL180UH045E36A 8809166EL16XC1-018-230A TXV 17,900 14.5 12.5 CX34-18/24A EL180UH045XE36A 8809167NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 14: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 14

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-018-230A TXV 18,000 14.5 12.2 CX34-18/24B EL180UH070E36B 8809168EL16XC1-018-230A TXV 18,000 14.5 12.2 CX34-18/24B EL180UH070XE36B 8809169EL16XC1-018-230A TXV 18,400 15.1 12.5 CX34-18/24B EL195UH030XE24B 8809170EL16XC1-018-230A TXV 18,400 15.1 12.5 CX34-18/24B EL195UH045XE24B 8809171EL16XC1-018-230A TXV 18,000 14.5 12.2 CX34-18/24B EL195UH045XE36B 8809172EL16XC1-018-230A TXV 18,000 14.5 12.2 CX34-18/24B EL296UH045XE36B 8809173EL16XC1-018-230A TXV 18,000 16 13 CX34-19 EL180UH045E36A 8809174EL16XC1-018-230A TXV 18,000 16 13 CX34-19 EL180UH045XE36A 8809176EL16XC1-018-230A TXV 18,000 16 13 CX34-25A EL180UH045E36A 8809177EL16XC1-018-230A TXV 18,000 16 13 CX34-25A EL180UH045XE36A 8809178EL16XC1-018-230A TXV 18,000 14.25 12.2 CX34-25A 8809179EL16XC1-018-230A TXV 18,000 15.5 12.5 CX34-25B EL180UH070E36B 8809180EL16XC1-018-230A TXV 18,000 15.5 12.5 CX34-25B EL180UH070XE36B 8809181EL16XC1-018-230A TXV 19,600 16 13 CX34-25B EL195UH030XE24B 8809182EL16XC1-018-230A TXV 19,600 16 13 CX34-25B EL195UH045XE24B 8809183EL16XC1-018-230A TXV 19,600 16 13 CX34-25B EL195UH045XE36B 8809184EL16XC1-018-230A TXV 19,600 16 13 CX34-25B EL296UH045XE36B 8809186EL16XC1-018-230A TXV 19,600 16 13 CX34-25B EL296UH045XV36B 8809187EL16XC1-018-230A TXV 19,600 16 13 CX34-25B EL296UH070XV36B 8809188EL16XC1-018-230A TXV 19,600 16 13 CX34-25B SLP98UH070XV36B 8809189EL16XC1-018-230A TXV 18,000 14.25 12.2 CX34-25B 8809190EL16XC1-018-230A TXV 18,000 15.5 12.5 CX34-30A EL180UH045E36A 8809191EL16XC1-018-230A TXV 18,000 15.5 12.5 CX34-30A EL180UH045XE36A 8809192EL16XC1-018-230A TXV 18,000 14.5 12.5 CX34-30B EL180UH070E36B 8809193EL16XC1-018-230A TXV 18,000 14.5 12.5 CX34-30B EL180UH070XE36B 8809194EL16XC1-018-230A TXV 18,800 15.5 12.5 CX34-30B EL195UH030XE24B 8809196EL16XC1-018-230A TXV 18,800 15.5 12.5 CX34-30B EL195UH045XE24B 8809197EL16XC1-018-230A TXV 18,000 15.1 12.5 CX34-30B EL195UH045XE36B 8809198EL16XC1-018-230A TXV 18,000 15.1 12.5 CX34-30B EL296UH045XE36B 8809199EL16XC1-018-230A TXV 18,000 16 13 CX34-31A EL180UH045E36A 8809200EL16XC1-018-230A TXV 18,000 16 13 CX34-31A EL180UH045XE36A 8809201EL16XC1-018-230A TXV 18,000 14.5 12.2 CX34-31A 8809202EL16XC1-018-230A TXV 18,000 15.5 13 CX34-31B EL180UH070E36B 8809203EL16XC1-018-230A TXV 18,000 15.5 13 CX34-31B EL180UH070XE36B 8809204EL16XC1-018-230A TXV 20,000 16 13.5 CX34-31B EL195UH030XE24B 8809205EL16XC1-018-230A TXV 20,000 16 13.5 CX34-31B EL195UH045XE24B 8809207EL16XC1-018-230A TXV 18,000 16 13 CX34-31B EL195UH045XE36B 8809208EL16XC1-018-230A TXV 18,000 16 13 CX34-31B EL296UH045XE36B 8809209EL16XC1-018-230A TXV 19,600 16 13.5 CX34-31B EL296UH045XV36B 8809210EL16XC1-018-230A TXV 19,600 17 13.5 CX34-31B EL296UH070XV36B 8809211EL16XC1-018-230A TXV 19,600 17 13.5 CX34-31B SLP98UH070XV36B 8809212EL16XC1-018-230A TXV 18,000 14.5 12.2 CX34-31B 8809213EL16XC1-018-230A TXV 18,800 15.5 12.5 CX35-18/24A EL180UH045E36A 8810885EL16XC1-018-230A TXV 18,800 15.5 12.5 CX35-18/24A EL180UH045XE36A 8810886EL16XC1-018-230A TXV 18,800 15.5 12.5 CX35-18/24B EL180UH070E36B 8809214EL16XC1-018-230A TXV 18,800 15.5 12.5 CX35-18/24B EL180UH070XE36B 8809216EL16XC1-018-230A TXV 18,800 15.5 12.5 CX35-18/24B EL195UH045XE36B 8809217EL16XC1-018-230A TXV 18,800 15.5 12.5 CX35-18/24B EL296UH045XE36B 8809218EL16XC1-018-230A TXV 18,000 16 13 CX35-24A EL180UH045E36A 8809219NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 15: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 15

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-018-230A TXV 18,000 16 13 CX35-24A EL180UH045XE36A 8809220EL16XC1-018-230A TXV 18,000 15.5 12.5 CX35-24B EL180UH070E36B 8809221EL16XC1-018-230A TXV 18,000 15.5 12.5 CX35-24B EL180UH070XE36B 8809222EL16XC1-018-230A TXV 19,800 16 13 CX35-24B EL195UH030XE24B 8809223EL16XC1-018-230A TXV 19,800 16 13 CX35-24B EL195UH045XE24B 8809224EL16XC1-018-230A TXV 19,600 16 13 CX35-24B EL195UH045XE36B 8809225EL16XC1-018-230A TXV 19,600 16 13 CX35-24B EL296UH045XE36B 8809226EL16XC1-018-230A TXV 19,600 16 13 CX35-24B EL296UH045XV36B 8809227EL16XC1-018-230A TXV 19,800 16 13 CX35-24B EL296UH070XV36B 8809228EL16XC1-018-230A TXV 19,800 16 13 CX35-24B SLP98UH070XV36B 8809229EL16XC1-018-230A TXV 18,000 16 13 CX35-30A EL180UH045E36A 8809230EL16XC1-018-230A TXV 18,000 16 13 CX35-30A EL180UH045XE36A 8809231EL16XC1-018-230A TXV 18,000 14.5 12.2 CX35-30A 8809232EL16XC1-018-230A TXV 18,000 15.5 13 CX35-30B EL180UH070E36B 8809233EL16XC1-018-230A TXV 18,000 15.5 13 CX35-30B EL180UH070XE36B 8809234EL16XC1-018-230A TXV 20,000 16 13.5 CX35-30B EL195UH030XE24B 8809235EL16XC1-018-230A TXV 20,000 16 13.5 CX35-30B EL195UH045XE24B 8809236EL16XC1-018-230A TXV 18,000 16 13 CX35-30B EL195UH045XE36B 8809237EL16XC1-018-230A TXV 18,000 16 13 CX35-30B EL296UH045XE36B 8809238EL16XC1-018-230A TXV 20,000 16 13.5 CX35-30B EL296UH045XV36B 8809239EL16XC1-018-230A TXV 20,000 17 13.5 CX35-30B EL296UH070XV36B 8809240EL16XC1-018-230A TXV 20,000 17 13.5 CX35-30B SLP98UH070XV36B 8809241EL16XC1-018-230A TXV 18,000 14.5 12.2 CX35-30B 8809242EL16XC1-024-230A RFC 24,000 14.25 12.2 C33-31A 8809453EL16XC1-024-230A RFC 24,000 14.25 12.2 C33-31B 8809471EL16XC1-024-230A RFC 24,000 14.25 12.5 C33-38A 8809500EL16XC1-024-230A RFC 24,000 14.25 12.5 C33-38B 8809518EL16XC1-024-230A RFC 24,000 14.25 12.2 C35-30A 8809567EL16XC1-024-230A RFC 24,000 14.25 12.2 C35-30B 8809585EL16XC1-024-230A RFC 24,000 14.25 12.2 C35-36A 8809592EL16XC1-024-230A RFC 24,000 14.25 12.2 C35-36B 8809609EL16XC1-024-230A RFC 24,000 14.25 12.2 CH33-31A 8809690EL16XC1-024-230A RFC 24,000 14.25 12.2 CH33-31B 8809705EL16XC1-024-230A RFC 24,000 14 12.2 CH33-42B 8810881EL16XC1-024-230A RFC 24,000 14.25 12.2 CH33-43B 8809731EL16XC1-024-230A TXV 24,000 16 13 C33-19 EL180UH045E36A 8809383EL16XC1-024-230A TXV 24,000 16 13 C33-19 EL180UH045XE36A 8809384EL16XC1-024-230A TXV 24,000 16 13 C33-19 SL280UH070V36A 8809385EL16XC1-024-230A TXV 24,000 16 13 C33-19 SL280UH070XV36A 8809386EL16XC1-024-230A TXV 23,400 14.5 12.5 C33-24A EL180UH045E36A 8809387EL16XC1-024-230A TXV 23,400 14.5 12.5 C33-24A EL180UH045XE36A 8809388EL16XC1-024-230A TXV 23,400 15.1 12.5 C33-24A SL280UH070V36A 8809389EL16XC1-024-230A TXV 23,400 15.1 12.5 C33-24A SL280UH070XV36A 8809390EL16XC1-024-230A TXV 23,000 15.1 12.5 C33-24B EL180UH070E36B 8809391EL16XC1-024-230A TXV 23,000 15.1 12.5 C33-24B EL180UH070XE36B 8809392EL16XC1-024-230A TXV 23,200 15.1 12.5 C33-24B EL195UH030XE24B 8809394EL16XC1-024-230A TXV 23,200 15.1 12.5 C33-24B EL195UH045XE24B 8809395EL16XC1-024-230A TXV 23,000 14.5 12.5 C33-24B EL195UH045XE36B 8809396EL16XC1-024-230A TXV 23,200 14.5 12.5 C33-24B EL195UH070XE36B 8809397NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 16: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 16

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 23,000 14.5 12.5 C33-24B EL296UH045XE36B 8809398EL16XC1-024-230A TXV 23,400 15.1 12.5 C33-24B EL296UH045XV36B 8809399EL16XC1-024-230A TXV 23,200 14.5 12.5 C33-24B EL296UH070XE36B 8809400EL16XC1-024-230A TXV 23,400 15.1 12.5 C33-24B EL296UH070XV36B 8809401EL16XC1-024-230A TXV 23,200 15.1 12.5 C33-24B SL280UH090V36B 8809402EL16XC1-024-230A TXV 23,200 14.5 12.5 C33-24B SL280UH090V48B 8809403EL16XC1-024-230A TXV 23,200 14.5 12.5 C33-24B SL280UH090XV48B 8809405EL16XC1-024-230A TXV 23,400 15.1 12.5 C33-24B SLP98UH070XV36B 8809406EL16XC1-024-230A TXV 23,400 15.1 12.5 C33-24C EL296UH090XV36C 8809407EL16XC1-024-230A TXV 23,400 15.1 12.5 C33-24C SLP98UH090XV36C 8809408EL16XC1-024-230A TXV 24,000 16 13 C33-25A EL180UH045E36A 8809409EL16XC1-024-230A TXV 24,000 16 13 C33-25A EL180UH045XE36A 8809410EL16XC1-024-230A TXV 24,000 16 13 C33-25A SL280UH070V36A 8809411EL16XC1-024-230A TXV 24,000 16 13 C33-25A SL280UH070XV36A 8809412EL16XC1-024-230A TXV 24,000 14.25 12.2 C33-25A 8809413EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL180UH070E36B 8809414EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL180UH070XE36B 8809415EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL195UH030XE24B 8809416EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL195UH045XE24B 8809417EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL195UH045XE36B 8809418EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL195UH070XE36B 8809419EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL296UH045XE36B 8809420EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL296UH045XV36B 8809421EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL296UH070XE36B 8809422EL16XC1-024-230A TXV 24,000 16 13 C33-25B EL296UH070XV36B 8809423EL16XC1-024-230A TXV 24,000 16 13 C33-25B SL280UH090V36B 8809424EL16XC1-024-230A TXV 24,000 16 13 C33-25B SL280UH090V48B 8809425EL16XC1-024-230A TXV 24,000 16 13 C33-25B SL280UH090XV48B 8809426EL16XC1-024-230A TXV 24,000 16 13 C33-25B SLP98UH070XV36B 8809427EL16XC1-024-230A TXV 24,000 14.25 12.2 C33-25B 8809428EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30A EL180UH045E36A 8809429EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30A EL180UH045XE36A 8809430EL16XC1-024-230A TXV 24,000 15.5 12.5 C33-30A SL280UH070V36A 8809431EL16XC1-024-230A TXV 24,000 15.5 12.5 C33-30A SL280UH070XV36A 8809432EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B EL180UH070E36B 8809433EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B EL180UH070XE36B 8809434EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B EL195UH030XE24B 8809435EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B EL195UH045XE24B 8809436EL16XC1-024-230A TXV 23,600 15.1 12.5 C33-30B EL195UH045XE36B 8809437EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B EL195UH070XE36B 8809438EL16XC1-024-230A TXV 23,600 15.1 12.5 C33-30B EL296UH045XE36B 8809439EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B EL296UH045XV36B 8809440EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B EL296UH070XE36B 8809441EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B EL296UH070XV36B 8809442EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B SL280UH090V36B 8809443EL16XC1-024-230A TXV 23,800 15.1 12.5 C33-30B SL280UH090V48B 8809444EL16XC1-024-230A TXV 23,800 15.1 12.5 C33-30B SL280UH090XV48B 8809445EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30B SLP98UH070XV36B 8809446EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30C EL296UH090XV36C 8809447NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 17: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 17

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 23,800 15.5 12.5 C33-30C SLP98UH090XV36C 8809448EL16XC1-024-230A TXV 24,000 16 13 C33-31A EL180UH045E36A 8809449EL16XC1-024-230A TXV 24,000 16 13 C33-31A EL180UH045XE36A 8809450EL16XC1-024-230A TXV 24,000 16 13 C33-31A SL280UH070V36A 8809451EL16XC1-024-230A TXV 24,000 16 13 C33-31A SL280UH070XV36A 8809452EL16XC1-024-230A TXV 24,000 14.5 12.2 C33-31A 8809454EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL180UH070E36B 8809455EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL180UH070XE36B 8809456EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL195UH030XE24B 8809458EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL195UH045XE24B 8809459EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL195UH045XE36B 8809460EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL195UH070XE36B 8809461EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL296UH045XE36B 8809462EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL296UH045XV36B 8809463EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL296UH070XE36B 8809464EL16XC1-024-230A TXV 24,000 16 13 C33-31B EL296UH070XV36B 8809465EL16XC1-024-230A TXV 24,000 16 13 C33-31B SL280UH090V36B 8809466EL16XC1-024-230A TXV 24,000 16 13 C33-31B SL280UH090V48B 8809468EL16XC1-024-230A TXV 24,000 16 13 C33-31B SL280UH090XV48B 8809469EL16XC1-024-230A TXV 24,000 16 13 C33-31B SLP98UH070XV36B 8809470EL16XC1-024-230A TXV 24,000 14.5 12.2 C33-31B 8809472EL16XC1-024-230A TXV 24,000 16 13 C33-36A EL180UH045E36A 8809473EL16XC1-024-230A TXV 24,000 16 13 C33-36A EL180UH045XE36A 8809474EL16XC1-024-230A TXV 24,000 16 13 C33-36A SL280UH070V36A 8809475EL16XC1-024-230A TXV 24,000 16 13 C33-36A SL280UH070XV36A 8809476EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL180UH070E36B 8809477EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL180UH070XE36B 8809479EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL195UH030XE24B 8809480EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL195UH045XE24B 8809481EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL195UH045XE36B 8809482EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL195UH070XE36B 8809483EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL296UH045XE36B 8809484EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL296UH045XV36B 8809485EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL296UH070XE36B 8809486EL16XC1-024-230A TXV 24,000 16 13 C33-36B EL296UH070XV36B 8809487EL16XC1-024-230A TXV 24,000 16 13 C33-36B SL280UH090V36B 8809489EL16XC1-024-230A TXV 24,000 16 13 C33-36B SL280UH090V48B 8809490EL16XC1-024-230A TXV 24,000 16 13 C33-36B SL280UH090XV48B 8809491EL16XC1-024-230A TXV 24,000 16 13 C33-36B SLP98UH070XV36B 8809492EL16XC1-024-230A TXV 24,000 16 13 C33-36C EL296UH090XV36C 8809493EL16XC1-024-230A TXV 24,000 16 13 C33-36C SLP98UH090XV36C 8809494EL16XC1-024-230A TXV 24,000 16 13 C33-38A EL180UH045E36A 8809495EL16XC1-024-230A TXV 24,000 16 13 C33-38A EL180UH045XE36A 8809496EL16XC1-024-230A TXV 24,000 16 13 C33-38A SL280UH070V36A 8809497EL16XC1-024-230A TXV 24,000 16 13 C33-38A SL280UH070XV36A 8809498EL16XC1-024-230A TXV 24,000 14.5 12.2 C33-38A 8809501EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL180UH070E36B 8809502EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL180UH070XE36B 8809503EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL195UH030XE24B 8809504NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 18: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 18

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL195UH045XE24B 8809506EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL195UH045XE36B 8809507EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL195UH070XE36B 8809508EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL296UH045XE36B 8809509EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL296UH045XV36B 8809510EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL296UH070XE36B 8809511EL16XC1-024-230A TXV 24,000 16 13 C33-38B EL296UH070XV36B 8809513EL16XC1-024-230A TXV 24,000 16 13 C33-38B SL280UH090V36B 8809514EL16XC1-024-230A TXV 24,000 16 13 C33-38B SL280UH090V48B 8809515EL16XC1-024-230A TXV 24,000 16 13 C33-38B SL280UH090XV48B 8809516EL16XC1-024-230A TXV 24,000 16 13 C33-38B SLP98UH070XV36B 8809517EL16XC1-024-230A TXV 24,000 14.5 12.2 C33-38B 8809519EL16XC1-024-230A TXV 24,000 16 13 C35-24A EL180UH045E36A 8809521EL16XC1-024-230A TXV 24,000 16 13 C35-24A EL180UH045XE36A 8809522EL16XC1-024-230A TXV 24,000 16 13 C35-24A SL280UH070V36A 8809523EL16XC1-024-230A TXV 24,000 16 13 C35-24A SL280UH070XV36A 8809524EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL180UH070E36B 8809525EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL180UH070XE36B 8809526EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL195UH030XE24B 8809527EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL195UH045XE24B 8809529EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL195UH045XE36B 8809530EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL195UH070XE36B 8809531EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL296UH045XE36B 8809532EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL296UH045XV36B 8809533EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL296UH070XE36B 8809534EL16XC1-024-230A TXV 24,000 16 13 C35-24B EL296UH070XV36B 8809535EL16XC1-024-230A TXV 24,000 16 13 C35-24B SL280UH090V36B 8809536EL16XC1-024-230A TXV 24,000 16 13 C35-24B SL280UH090V48B 8809537EL16XC1-024-230A TXV 24,000 16 13 C35-24B SL280UH090XV48B 8809539EL16XC1-024-230A TXV 24,000 16 13 C35-24B SLP98UH070XV36B 8809540EL16XC1-024-230A TXV 24,000 16 13 C35-30/36A EL180UH045E36A 8809541EL16XC1-024-230A TXV 24,000 16 13 C35-30/36A EL180UH045XE36A 8809542EL16XC1-024-230A TXV 24,000 16 13 C35-30/36A SL280UH070V36A 8809543EL16XC1-024-230A TXV 24,000 16 13 C35-30/36A SL280UH070XV36A 8809544EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL180UH070E36B 8809545EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL180UH070XE36B 8809546EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL195UH030XE24B 8809547EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL195UH045XE24B 8809548EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL195UH045XE36B 8809550EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL195UH070XE36B 8809551EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL296UH045XE36B 8809552EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL296UH045XV36B 8809553EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL296UH070XE36B 8809554EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B EL296UH070XV36B 8809555EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B SL280UH090V36B 8809556EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B SL280UH090V48B 8809557EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B SL280UH090XV48B 8809558EL16XC1-024-230A TXV 24,000 16 13 C35-30/36B SLP98UH070XV36B 8809560EL16XC1-024-230A TXV 24,000 16 13 C35-30/36C EL296UH090XV36C 8809561NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 19: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 19

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 16 13 C35-30/36C SLP98UH090XV36C 8809562EL16XC1-024-230A TXV 24,000 16 13 C35-30A EL180UH045E36A 8809563EL16XC1-024-230A TXV 24,000 16 13 C35-30A EL180UH045XE36A 8809564EL16XC1-024-230A TXV 24,000 16 13 C35-30A SL280UH070V36A 8809565EL16XC1-024-230A TXV 24,000 16 13 C35-30A SL280UH070XV36A 8809566EL16XC1-024-230A TXV 24,000 14.5 12.2 C35-30A 8809568EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL180UH070E36B 8809569EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL180UH070XE36B 8809571EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL195UH030XE24B 8809572EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL195UH045XE24B 8809573EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL195UH045XE36B 8809574EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL195UH070XE36B 8809575EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL296UH045XE36B 8809576EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL296UH045XV36B 8809577EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL296UH070XE36B 8809578EL16XC1-024-230A TXV 24,000 16 13 C35-30B EL296UH070XV36B 8809579EL16XC1-024-230A TXV 24,000 16 13 C35-30B SL280UH090V36B 8809581EL16XC1-024-230A TXV 24,000 16 13 C35-30B SL280UH090V48B 8809582EL16XC1-024-230A TXV 24,000 16 13 C35-30B SL280UH090XV48B 8809583EL16XC1-024-230A TXV 24,000 16 13 C35-30B SLP98UH070XV36B 8809584EL16XC1-024-230A TXV 24,000 14.5 12.2 C35-30B 8809586EL16XC1-024-230A TXV 24,000 16 13 C35-36A EL180UH045E36A 8809587EL16XC1-024-230A TXV 24,000 16 13 C35-36A EL180UH045XE36A 8809588EL16XC1-024-230A TXV 24,000 16 13 C35-36A SL280UH070V36A 8809589EL16XC1-024-230A TXV 24,000 16 13 C35-36A SL280UH070XV36A 8809591EL16XC1-024-230A TXV 24,000 14.5 12.2 C35-36A 8809593EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL180UH070E36B 8809594EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL180UH070XE36B 8809595EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL195UH030XE24B 8809596EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL195UH045XE24B 8809597EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL195UH045XE36B 8809598EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL195UH070XE36B 8809599EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL296UH045XE36B 8809600EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL296UH045XV36B 8809602EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL296UH070XE36B 8809603EL16XC1-024-230A TXV 24,000 16 13 C35-36B EL296UH070XV36B 8809604EL16XC1-024-230A TXV 24,000 16 13 C35-36B SL280UH090V36B 8809605EL16XC1-024-230A TXV 24,000 16 13 C35-36B SL280UH090V48B 8809606EL16XC1-024-230A TXV 24,000 16 13 C35-36B SL280UH090XV48B 8809607EL16XC1-024-230A TXV 24,000 16 13 C35-36B SLP98UH070XV36B 8809608EL16XC1-024-230A TXV 24,000 14.5 12.2 C35-36B 8809610EL16XC1-024-230A TXV 24,000 16 13 CBA27UHE-024 10259403EL16XC1-024-230A TXV 24,000 16 13 CBA27UHE-030 10259404EL16XC1-024-230A TXV 24,000 14.5 12.2 CBX25UH-036 8809611EL16XC1-024-230A TXV 24,000 16 13 CBX25UHV-024 8809613EL16XC1-024-230A TXV 24,000 16 13 CBX25UHV-030 8809614EL16XC1-024-230A TXV 24,000 16 13 CBX25UHV-036 8809615EL16XC1-024-230A TXV 24,000 16 13 CBX27UH-024 8809616EL16XC1-024-230A TXV 24,000 16 13 CBX27UH-030 8809617NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 20: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 20

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 14.5 12.2 CBX32M-018/024 8809618EL16XC1-024-230A TXV 24,000 15.1 12.5 CBX32M-030 8809619EL16XC1-024-230A TXV 24,000 15.5 12.5 CBX32MV-018/024 8809620EL16XC1-024-230A TXV 24,000 16 13 CBX32MV-024/030 8809621EL16XC1-024-230A TXV 24,000 16 13 CBX40UHV-024 8809623EL16XC1-024-230A TXV 23,800 15.5 12.5 CH23-31 EL180UH045E36A 8809624EL16XC1-024-230A TXV 23,800 15.5 12.5 CH23-31 EL180UH045XE36A 8809625EL16XC1-024-230A TXV 23,800 15.5 13 CH23-31 EL180UH070E36B 8809626EL16XC1-024-230A TXV 23,800 15.5 13 CH23-31 EL180UH070XE36B 8809627EL16XC1-024-230A TXV 23,200 15.5 12.5 CH23-31 EL195UH030XE24B 8809628EL16XC1-024-230A TXV 23,200 15.5 12.5 CH23-31 EL195UH045XE24B 8809629EL16XC1-024-230A TXV 23,400 15.1 12.5 CH23-31 EL195UH045XE36B 8809630EL16XC1-024-230A TXV 23,800 15.5 12.5 CH23-31 EL195UH070XE36B 8809631EL16XC1-024-230A TXV 23,400 15.1 12.5 CH23-31 EL296UH045XE36B 8809632EL16XC1-024-230A TXV 23,600 15.5 12.5 CH23-31 EL296UH045XV36B 8809634EL16XC1-024-230A TXV 23,800 15.5 12.5 CH23-31 EL296UH070XE36B 8809635EL16XC1-024-230A TXV 23,600 15.5 12.5 CH23-31 EL296UH070XV36B 8809636EL16XC1-024-230A TXV 23,600 15.5 12.5 CH23-31 SL280UH070V36A 8809637EL16XC1-024-230A TXV 23,600 15.5 12.5 CH23-31 SL280UH070XV36A 8809638EL16XC1-024-230A TXV 23,400 15.5 12.5 CH23-31 SL280UH090V36B 8809639EL16XC1-024-230A TXV 23,600 15.5 12.5 CH23-31 SLP98UH070XV36B 8809640EL16XC1-024-230A TXV 24,200 16 13 CH23-41 EL180UH045E36A 8809641EL16XC1-024-230A TXV 24,200 16 13 CH23-41 EL180UH045XE36A 8809642EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL180UH070E36B 8809643EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL180UH070XE36B 8809645EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL195UH030XE24B 8809646EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL195UH045XE24B 8809647EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL195UH045XE36B 8809648EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL195UH070XE36B 8809649EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL296UH045XE36B 8809650EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL296UH045XV36B 8809651EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL296UH070XE36B 8809652EL16XC1-024-230A TXV 24,000 16 13 CH23-41 EL296UH070XV36B 8809653EL16XC1-024-230A TXV 24,000 16 13 CH23-41 SL280UH070V36A 8809655EL16XC1-024-230A TXV 24,000 16 13 CH23-41 SL280UH070XV36A 8809656EL16XC1-024-230A TXV 24,000 16 13 CH23-41 SL280UH090V36B 8809657EL16XC1-024-230A TXV 24,000 16 13 CH23-41 SLP98UH070XV36B 8809658EL16XC1-024-230A TXV 24,000 15.5 12.5 CH33-19 EL180UH045E36A 8809659EL16XC1-024-230A TXV 24,000 15.5 12.5 CH33-19 EL180UH045XE36A 8809660EL16XC1-024-230A TXV 24,000 15.5 12.5 CH33-19 SL280UH070V36A 8809661EL16XC1-024-230A TXV 24,000 15.5 12.5 CH33-19 SL280UH070XV36A 8809662EL16XC1-024-230A TXV 24,000 15.5 12.5 CH33-24/30 EL180UH045E36A 8809663EL16XC1-024-230A TXV 24,000 15.5 12.5 CH33-24/30 EL180UH045XE36A 8809664EL16XC1-024-230A TXV 24,000 15.5 12.5 CH33-24/30 SL280UH070V36A 8809666EL16XC1-024-230A TXV 24,000 15.5 12.5 CH33-24/30 SL280UH070XV36A 8809667EL16XC1-024-230A TXV 24,000 16 13 CH33-25A EL180UH045E36A 8809668EL16XC1-024-230A TXV 24,000 16 13 CH33-25A EL180UH045XE36A 8809669EL16XC1-024-230A TXV 24,000 16 13 CH33-25A SL280UH070V36A 8809670EL16XC1-024-230A TXV 24,000 16 13 CH33-25A SL280UH070XV36A 8809671NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 21: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 21

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL180UH070E36B 8809672EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL180UH070XE36B 8809673EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL195UH030XE24B 8809674EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL195UH045XE24B 8809676EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL195UH045XE36B 8809677EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL195UH070XE36B 8809678EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL296UH045XE36B 8809679EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL296UH045XV36B 8809680EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL296UH070XE36B 8809681EL16XC1-024-230A TXV 24,000 16 13 CH33-25B EL296UH070XV36B 8809682EL16XC1-024-230A TXV 24,000 16 13 CH33-25B SL280UH090V36B 8809683EL16XC1-024-230A TXV 24,000 16 13 CH33-25B SLP98UH070XV36B 8809684EL16XC1-024-230A TXV 24,000 16 13 CH33-31A EL180UH045E36A 8809685EL16XC1-024-230A TXV 24,000 16 13 CH33-31A EL180UH045XE36A 8809687EL16XC1-024-230A TXV 24,000 16 13 CH33-31A SL280UH070V36A 8809688EL16XC1-024-230A TXV 24,000 16 13 CH33-31A SL280UH070XV36A 8809689EL16XC1-024-230A TXV 24,000 14.5 12.2 CH33-31A 8809691EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL180UH070E36B 8809692EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL180UH070XE36B 8809693EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL195UH030XE24B 8809694EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL195UH045XE24B 8809695EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL195UH045XE36B 8809697EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL195UH070XE36B 8809698EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL296UH045XE36B 8809699EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL296UH045XV36B 8809700EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL296UH070XE36B 8809701EL16XC1-024-230A TXV 24,000 16 13 CH33-31B EL296UH070XV36B 8809702EL16XC1-024-230A TXV 24,000 16 13 CH33-31B SL280UH090V36B 8809703EL16XC1-024-230A TXV 24,000 16 13 CH33-31B SLP98UH070XV36B 8809704EL16XC1-024-230A TXV 24,000 14.5 12.2 CH33-31B 8809706EL16XC1-024-230A TXV 24,000 16 13 CH33-36A EL180UH045E36A 8809708EL16XC1-024-230A TXV 24,000 16 13 CH33-36A EL180UH045XE36A 8809709EL16XC1-024-230A TXV 24,000 16 13 CH33-36A SL280UH070V36A 8809710EL16XC1-024-230A TXV 24,000 16 13 CH33-36A SL280UH070XV36A 8809711EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL180UH070E36B 8809712EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL180UH070XE36B 8809713EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL195UH030XE24B 8809714EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL195UH045XE24B 8809715EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL195UH045XE36B 8809716EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL195UH070XE36B 8809717EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL296UH045XE36B 8809719EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL296UH045XV36B 8809720EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL296UH070XE36B 8809721EL16XC1-024-230A TXV 24,000 16 13 CH33-36B EL296UH070XV36B 8809722EL16XC1-024-230A TXV 24,000 16 13 CH33-36B SL280UH090V36B 8809723EL16XC1-024-230A TXV 24,000 16 13 CH33-36B SLP98UH070XV36B 8809724EL16XC1-024-230A TXV 24,000 16 13 CH33-36C EL296UH090XV36C 8809725EL16XC1-024-230A TXV 24,000 16 13 CH33-36C SLP98UH090XV36C 8809726EL16XC1-024-230A TXV 24,000 16 13 CH33-42 EL195UH030XE24B 8809727NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 22: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 22

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 16 13 CH33-42 EL195UH045XE24B 8809729EL16XC1-024-230A TXV 24,000 16 13.5 CH33-43B EL195UH030XE24B 8810882EL16XC1-024-230A TXV 24,000 16 13.5 CH33-43B EL195UH045XE24B 8810883EL16XC1-024-230A TXV 24,000 16 13 CH33-43B EL195UH045XE36B 8809730EL16XC1-024-230A TXV 24,000 15.5 12.5 CH35-18A EL180UH045E36A 8809732EL16XC1-024-230A TXV 24,000 15.5 12.5 CH35-18A EL180UH045XE36A 8809733EL16XC1-024-230A TXV 24,000 16 13 CH35-18A SL280UH070V36A 8809734EL16XC1-024-230A TXV 24,000 16 13 CH35-18A SL280UH070XV36A 8809735EL16XC1-024-230A TXV 24,000 16 13 CH35-24A EL180UH045E36A 8809737EL16XC1-024-230A TXV 24,000 16 13 CH35-24A EL180UH045XE36A 8809738EL16XC1-024-230A TXV 24,000 16 13 CH35-24A SL280UH070V36A 8809739EL16XC1-024-230A TXV 24,000 16 13 CH35-24A SL280UH070XV36A 8809740EL16XC1-024-230A TXV 24,000 16 13 CH35-24B EL180UH070E36B 8809741EL16XC1-024-230A TXV 24,000 16 13 CH35-24B EL180UH070XE36B 8809742EL16XC1-024-230A TXV 24,000 16 13 CH35-24B EL195UH030XE24B 8809743EL16XC1-024-230A TXV 24,000 16 13 CH35-24B EL195UH045XE24B 8809744EL16XC1-024-230A TXV 24,000 16 13 CH35-24B EL195UH045XE36B 8809745EL16XC1-024-230A TXV 24,000 16 13 CH35-24B EL195UH070XE36B 8809746EL16XC1-024-230A TXV 24,000 16 13 CH35-24B EL296UH045XV36B 8809748EL16XC1-024-230A TXV 24,000 16 13 CH35-24B EL296UH070XV36B 8809749EL16XC1-024-230A TXV 24,000 16 13 CH35-24B SL280UH090V36B 8809750EL16XC1-024-230A TXV 24,000 16 13 CH35-24B SLP98UH070XV36B 8809751EL16XC1-024-230A TXV 24,000 14.5 12.2 CH35-24B 8809752EL16XC1-024-230A TXV 24,000 16 13 CH35-30A EL180UH045E36A 8809753EL16XC1-024-230A TXV 24,000 16 13 CH35-30A EL180UH045XE36A 8809754EL16XC1-024-230A TXV 24,000 16 13 CH35-30A SL280UH070V36A 8809755EL16XC1-024-230A TXV 24,000 16 13 CH35-30A SL280UH070XV36A 8809756EL16XC1-024-230A TXV 24,000 14.5 12.2 CH35-30A 8809758EL16XC1-024-230A TXV 24,000 16 13 CH35-30B EL180UH070E36B 8809759EL16XC1-024-230A TXV 24,000 16 13 CH35-30B EL180UH070XE36B 8809760EL16XC1-024-230A TXV 24,000 16 13 CH35-30B EL195UH030XE24B 8809761EL16XC1-024-230A TXV 24,000 16 13 CH35-30B EL195UH045XE24B 8809762EL16XC1-024-230A TXV 24,000 16 13 CH35-30B EL195UH045XE36B 8809763EL16XC1-024-230A TXV 24,000 16 13 CH35-30B EL195UH070XE36B 8809764EL16XC1-024-230A TXV 24,000 16 13 CH35-30B EL296UH045XV36B 8809765EL16XC1-024-230A TXV 24,000 16 13 CH35-30B EL296UH070XV36B 8809766EL16XC1-024-230A TXV 24,000 16 13 CH35-30B SL280UH090V36B 8809768EL16XC1-024-230A TXV 24,000 16 13 CH35-30B SLP98UH070XV36B 8809769EL16XC1-024-230A TXV 24,000 14.5 12.2 CH35-30B 8809770EL16XC1-024-230A TXV 24,000 16 13 CH35-36A EL180UH045E36A 8809771EL16XC1-024-230A TXV 24,000 16 13 CH35-36A EL180UH045XE36A 8809772EL16XC1-024-230A TXV 24,000 16 13 CH35-36A SL280UH070V36A 8809773EL16XC1-024-230A TXV 24,000 16 13 CH35-36A SL280UH070XV36A 8809774EL16XC1-024-230A TXV 24,000 16 13 CH35-36B EL180UH070E36B 8809775EL16XC1-024-230A TXV 24,000 16 13 CH35-36B EL180UH070XE36B 8809776EL16XC1-024-230A TXV 24,000 16 13 CH35-36B EL195UH030XE24B 8809777EL16XC1-024-230A TXV 24,000 16 13 CH35-36B EL195UH045XE24B 8809779EL16XC1-024-230A TXV 24,000 16 13 CH35-36B EL195UH045XE36B 8809780EL16XC1-024-230A TXV 24,000 16 13 CH35-36B EL195UH070XE36B 8809781NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 23: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 23

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 16 13 CH35-36B EL296UH045XV36B 8809782EL16XC1-024-230A TXV 24,000 16 13 CH35-36B EL296UH070XV36B 8809783EL16XC1-024-230A TXV 24,000 16 13 CH35-36B SL280UH090V36B 8809784EL16XC1-024-230A TXV 24,000 16 13 CH35-36B SLP98UH070XV36B 8809785EL16XC1-024-230A TXV 24,000 16 13 CH35-36C EL296UH090XV36C 8809786EL16XC1-024-230A TXV 24,000 16 13 CH35-36C SLP98UH090XV36C 8809787EL16XC1-024-230A TXV 23,200 15.1 12.5 CR33-24A EL180DF045E36A 8809789EL16XC1-024-230A TXV 23,400 15.1 12.5 CR33-24A SL280DF070V36A 8809790EL16XC1-024-230A TXV 23,400 15.1 12.5 CR33-24B EL180DF070E36B 8809791EL16XC1-024-230A TXV 23,200 15.1 12.5 CR33-24B EL195DF045XE36B 8809792EL16XC1-024-230A TXV 23,200 15.1 12.5 CR33-24B EL195DF070XE48B 8809793EL16XC1-024-230A TXV 23,200 15.1 12.5 CR33-24B EL296DF045XE36B 8809794EL16XC1-024-230A TXV 23,600 15.1 12.5 CR33-24B EL296DF045XV36B 8809795EL16XC1-024-230A TXV 23,200 15.1 12.5 CR33-24B EL296DF070XE48B 8809797EL16XC1-024-230A TXV 23,800 14.5 12.5 CR33-24B EL296DF070XV48B 8809798EL16XC1-024-230A TXV 23,200 15.1 12.5 CR33-24B SLP98DF070XV36B 8809799EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36A EL180DF045E36A 8809800EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36A SL280DF070V36A 8809801EL16XC1-024-230A TXV 24,000 14.5 12.2 CR33-30/36A 8809802EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36B EL180DF070E36B 8809804EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36B EL195DF045XE36B 8809805EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36B EL195DF070XE48B 8809806EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36B EL296DF045XE36B 8809807EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36B EL296DF045XV36B 8809808EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36B EL296DF070XE48B 8809809EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36B EL296DF070XV48B 8809810EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36B SL280DF090V48B 8809812EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36B SLP98DF070XV36B 8809813EL16XC1-024-230A TXV 24,000 14.5 12.2 CR33-30/36B 8809814EL16XC1-024-230A TXV 24,000 16 13 CR33-30/36C SLP98DF090XV36C 8809815EL16XC1-024-230A TXV 24,000 14.5 12.2 CR33-30/36C 8809816EL16XC1-024-230A TXV 23,400 14.5 12.5 CX34-18/24A EL180UH045E36A 8809817EL16XC1-024-230A TXV 23,400 14.5 12.5 CX34-18/24A EL180UH045XE36A 8809819EL16XC1-024-230A TXV 24,000 16 13 CX34-19 EL180UH045E36A 8809820EL16XC1-024-230A TXV 24,000 16 13 CX34-19 EL180UH045XE36A 8809821EL16XC1-024-230A TXV 24,000 16 13 CX34-19 SL280UH070V36A 8809822EL16XC1-024-230A TXV 24,000 16 13 CX34-19 SL280UH070XV36A 8809823EL16XC1-024-230A TXV 24,000 16 13 CX34-25A EL180UH045E36A 8809824EL16XC1-024-230A TXV 24,000 16 13 CX34-25A EL180UH045XE36A 8809825EL16XC1-024-230A TXV 24,000 16 13 CX34-25A SL280UH070V36A 8809826EL16XC1-024-230A TXV 24,000 16 13 CX34-25A SL280UH070XV36A 8809827EL16XC1-024-230A TXV 24,000 14.25 12.2 CX34-25A 8809828EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL180UH070E36B 8809829EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL180UH070XE36B 8809830EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL195UH030XE24B 8809831EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL195UH045XE24B 8809833EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL195UH045XE36B 8809834EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL195UH070XE36B 8809835EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL296UH045XE36B 8809836NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 24: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 24

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL296UH045XV36B 8809837EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL296UH070XE36B 8809838EL16XC1-024-230A TXV 24,000 16 13 CX34-25B EL296UH070XV36B 8809840EL16XC1-024-230A TXV 24,000 16 13 CX34-25B SL280UH090V36B 8809841EL16XC1-024-230A TXV 24,000 16 13 CX34-25B SL280UH090V48B 8809842EL16XC1-024-230A TXV 24,000 16 13 CX34-25B SL280UH090XV48B 8809843EL16XC1-024-230A TXV 24,000 16 13 CX34-25B SLP98UH070XV36B 8809844EL16XC1-024-230A TXV 24,000 14.25 12.2 CX34-25B 8809845EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30A EL180UH045E36A 8809847EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30A EL180UH045XE36A 8809848EL16XC1-024-230A TXV 24,000 15.5 12.5 CX34-30A SL280UH070V36A 8809849EL16XC1-024-230A TXV 24,000 15.5 12.5 CX34-30A SL280UH070XV36A 8809850EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B EL180UH070E36B 8809851EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B EL180UH070XE36B 8809852EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B EL195UH030XE24B 8809853EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B EL195UH045XE24B 8809855EL16XC1-024-230A TXV 23,600 15.1 12.5 CX34-30B EL195UH045XE36B 8809856EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B EL195UH070XE36B 8809857EL16XC1-024-230A TXV 23,600 15.1 12.5 CX34-30B EL296UH045XE36B 8809858EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B EL296UH045XV36B 8809859EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B EL296UH070XE36B 8809860EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B EL296UH070XV36B 8809862EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B SL280UH090V36B 8809863EL16XC1-024-230A TXV 23,800 15.1 12.5 CX34-30B SL280UH090V48B 8809864EL16XC1-024-230A TXV 23,800 15.1 12.5 CX34-30B SL280UH090XV48B 8809865EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30B SLP98UH070XV36B 8809866EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30C EL296UH090XV36C 8809867EL16XC1-024-230A TXV 23,800 15.5 12.5 CX34-30C SLP98UH090XV36C 8809868EL16XC1-024-230A TXV 24,000 16 13 CX34-31A EL180UH045E36A 8809870EL16XC1-024-230A TXV 24,000 16 13 CX34-31A EL180UH045XE36A 8809871EL16XC1-024-230A TXV 24,000 16 13 CX34-31A SL280UH070V36A 8809872EL16XC1-024-230A TXV 24,000 16 13 CX34-31A SL280UH070XV36A 8809873EL16XC1-024-230A TXV 24,000 14.5 12.2 CX34-31A 8809874EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL180UH070E36B 8809875EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL180UH070XE36B 8809877EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL195UH030XE24B 8809878EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL195UH045XE24B 8809879EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL195UH045XE36B 8809880EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL195UH070XE36B 8809881EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL296UH045XE36B 8809882EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL296UH045XV36B 8809884EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL296UH070XE36B 8809885EL16XC1-024-230A TXV 24,000 16 13 CX34-31B EL296UH070XV36B 8809886EL16XC1-024-230A TXV 24,000 16 13 CX34-31B SL280UH090V36B 8809887EL16XC1-024-230A TXV 24,000 16 13 CX34-31B SL280UH090V48B 8809888EL16XC1-024-230A TXV 24,000 16 13 CX34-31B SL280UH090XV48B 8809889EL16XC1-024-230A TXV 24,000 16 13 CX34-31B SLP98UH070XV36B 8809890EL16XC1-024-230A TXV 24,000 14.5 12.2 CX34-31B 8809891EL16XC1-024-230A TXV 24,000 16 13 CX34-36A EL180UH045E36A 8809892NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 25: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 25

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 16 13 CX34-36A EL180UH045XE36A 8809893EL16XC1-024-230A TXV 24,000 16 13 CX34-36A SL280UH070V36A 8809894EL16XC1-024-230A TXV 24,000 16 13 CX34-36A SL280UH070XV36A 8809895EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL180UH070E36B 8809896EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL180UH070XE36B 8809897EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL195UH030XE24B 8809898EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL195UH045XE24B 8809899EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL195UH045XE36B 8809900EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL195UH070XE36B 8809901EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL296UH045XE36B 8809902EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL296UH045XV36B 8809903EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL296UH070XE36B 8809904EL16XC1-024-230A TXV 24,000 16 13 CX34-36B EL296UH070XV36B 8809905EL16XC1-024-230A TXV 24,000 16 13 CX34-36B SL280UH090V36B 8809906EL16XC1-024-230A TXV 24,000 16 13 CX34-36B SL280UH090V48B 8809907EL16XC1-024-230A TXV 24,000 16 13 CX34-36B SL280UH090XV48B 8809908EL16XC1-024-230A TXV 24,000 16 13 CX34-36B SLP98UH070XV36B 8809909EL16XC1-024-230A TXV 24,000 16 13 CX34-36C EL296UH090XV36C 8809910EL16XC1-024-230A TXV 24,000 16 13 CX34-36C SLP98UH090XV36C 8809911EL16XC1-024-230A TXV 24,000 16 13 CX34-38A EL180UH045E36A 8809912EL16XC1-024-230A TXV 24,000 16 13 CX34-38A EL180UH045XE36A 8809913EL16XC1-024-230A TXV 24,000 16 13 CX34-38A SL280UH070V36A 8809914EL16XC1-024-230A TXV 24,000 16 13 CX34-38A SL280UH070XV36A 8809915EL16XC1-024-230A TXV 24,000 14.5 12.2 CX34-38A 8809916EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL180UH070E36B 8809917EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL180UH070XE36B 8809918EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL195UH030XE24B 8809919EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL195UH045XE24B 8809920EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL195UH045XE36B 8809921EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL195UH070XE36B 8809922EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL296UH045XE36B 8809923EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL296UH045XV36B 8809924EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL296UH070XE36B 8809925EL16XC1-024-230A TXV 24,000 16 13 CX34-38B EL296UH070XV36B 8809926EL16XC1-024-230A TXV 24,000 16 13 CX34-38B SL280UH090V36B 8809927EL16XC1-024-230A TXV 24,000 16 13 CX34-38B SL280UH090V48B 8809928EL16XC1-024-230A TXV 24,000 16 13 CX34-38B SL280UH090XV48B 8809929EL16XC1-024-230A TXV 24,000 16 13 CX34-38B SLP98UH070XV36B 8809930EL16XC1-024-230A TXV 24,000 14.5 12.2 CX34-38B 8809931EL16XC1-024-230A TXV 23,800 15.1 12.5 CX35-18/24A EL180UH045E36A 8809932EL16XC1-024-230A TXV 23,800 15.1 12.5 CX35-18/24A EL180UH045XE36A 8809933EL16XC1-024-230A TXV 24,000 16 13 CX35-24A EL180UH045E36A 8809934EL16XC1-024-230A TXV 24,000 16 13 CX35-24A EL180UH045XE36A 8809935EL16XC1-024-230A TXV 24,000 16 13 CX35-24A SL280UH070V36A 8809936EL16XC1-024-230A TXV 24,000 16 13 CX35-24A SL280UH070XV36A 8809937EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL180UH070E36B 8809938EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL180UH070XE36B 8809939EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL195UH030XE24B 8809940EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL195UH045XE24B 8809941NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 26: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 26

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL195UH045XE36B 8809942EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL195UH070XE36B 8809943EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL296UH045XE36B 8809944EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL296UH045XV36B 8809945EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL296UH070XE36B 8809946EL16XC1-024-230A TXV 24,000 16 13 CX35-24B EL296UH070XV36B 8809947EL16XC1-024-230A TXV 24,000 16 13 CX35-24B SL280UH090V36B 8809948EL16XC1-024-230A TXV 24,000 16 13 CX35-24B SL280UH090V48B 8809949EL16XC1-024-230A TXV 24,000 16 13 CX35-24B SL280UH090XV48B 8809950EL16XC1-024-230A TXV 24,000 16 13 CX35-24B SLP98UH070XV36B 8809951EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36A EL180UH045E36A 8809952EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36A EL180UH045XE36A 8809953EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36A SL280UH070V36A 8809954EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36A SL280UH070XV36A 8809955EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL180UH070E36B 8809956EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL180UH070XE36B 8809957EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL195UH030XE24B 8809958EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL195UH045XE24B 8809959EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL195UH045XE36B 8809960EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL195UH070XE36B 8809961EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL296UH045XE36B 8809962EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL296UH045XV36B 8809963EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL296UH070XE36B 8809964EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B EL296UH070XV36B 8809965EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B SL280UH090V36B 8809966EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B SL280UH090V48B 8809967EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B SL280UH090XV48B 8809968EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36B SLP98UH070XV36B 8809969EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36C EL296UH090XV36C 8809970EL16XC1-024-230A TXV 24,000 16 13 CX35-30/36C SLP98UH090XV36C 8809971EL16XC1-024-230A TXV 24,000 16 13 CX35-30A EL180UH045E36A 8809972EL16XC1-024-230A TXV 24,000 16 13 CX35-30A EL180UH045XE36A 8809973EL16XC1-024-230A TXV 24,000 16 13 CX35-30A SL280UH070V36A 8809974EL16XC1-024-230A TXV 24,000 16 13 CX35-30A SL280UH070XV36A 8809975EL16XC1-024-230A TXV 24,000 14.5 12.2 CX35-30A 8809976EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL180UH070E36B 8809977EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL180UH070XE36B 8809978EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL195UH030XE24B 8809979EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL195UH045XE24B 8809980EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL195UH045XE36B 8809981EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL195UH070XE36B 8809982EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL296UH045XE36B 8809983EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL296UH045XV36B 8809984EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL296UH070XE36B 8809985EL16XC1-024-230A TXV 24,000 16 13 CX35-30B EL296UH070XV36B 8809986EL16XC1-024-230A TXV 24,000 16 13 CX35-30B SL280UH090V36B 8809987EL16XC1-024-230A TXV 24,000 16 13 CX35-30B SL280UH090V48B 8809988EL16XC1-024-230A TXV 24,000 16 13 CX35-30B SL280UH090XV48B 8809989EL16XC1-024-230A TXV 24,000 16 13 CX35-30B SLP98UH070XV36B 8809990NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 27: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 27

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-024-230A TXV 24,000 14.5 12.2 CX35-30B 8809991EL16XC1-024-230A TXV 24,000 16 13 CX35-36A EL180UH045E36A 8809992EL16XC1-024-230A TXV 24,000 16 13 CX35-36A EL180UH045XE36A 8809993EL16XC1-024-230A TXV 24,000 16 13 CX35-36A SL280UH070V36A 8809994EL16XC1-024-230A TXV 24,000 16 13 CX35-36A SL280UH070XV36A 8809995EL16XC1-024-230A TXV 24,000 14.5 12.2 CX35-36A 8809996EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL180UH070E36B 8809997EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL180UH070XE36B 8809998EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL195UH030XE24B 8809999EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL195UH045XE24B 8810000EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL195UH045XE36B 8810001EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL195UH070XE36B 8810002EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL296UH045XE36B 8810003EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL296UH045XV36B 8810004EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL296UH070XE36B 8810005EL16XC1-024-230A TXV 24,000 16 13 CX35-36B EL296UH070XV36B 8810006EL16XC1-024-230A TXV 24,000 16 13 CX35-36B SL280UH090V36B 8810007EL16XC1-024-230A TXV 24,000 16 13 CX35-36B SL280UH090V48B 8810008EL16XC1-024-230A TXV 24,000 16 13 CX35-36B SL280UH090XV48B 8810009EL16XC1-024-230A TXV 24,000 16 13 CX35-36B SLP98UH070XV36B 8810010EL16XC1-024-230A TXV 24,000 14.5 12.2 CX35-36B 8810011EL16XC1-030-230A RFC 28,600 14 12.2 C33-31A 8810274EL16XC1-030-230A RFC 28,600 14 12.2 C33-31B 8810288EL16XC1-030-230A RFC 28,800 14.25 12.2 C33-38A 8810314EL16XC1-030-230A RFC 28,800 14.25 12.2 C33-38B 8810328EL16XC1-030-230A RFC 28,800 14.25 12.2 C33-43 8810354EL16XC1-030-230A RFC 28,600 14.25 12.2 C35-30B 8810884EL16XC1-030-230A RFC 28,600 14.25 12.2 CH33-31A 8810513EL16XC1-030-230A RFC 28,800 14.25 12.2 CH33-31B 8810527EL16XC1-030-230A RFC 29,200 14.5 12.5 CH33-43B 8810571EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-25A EL180UH045E36A 8810235EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-25A EL180UH045XE36A 8810236EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-25A SL280UH070V36A 8810238EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-25A SL280UH070XV36A 8810239EL16XC1-030-230A TXV 28,600 15.5 12.5 C33-25B EL180UH070E36B 8810240EL16XC1-030-230A TXV 28,600 15.5 12.5 C33-25B EL180UH070XE36B 8810241EL16XC1-030-230A TXV 28,600 15.5 13 C33-25B EL180UH090E48B 8810242EL16XC1-030-230A TXV 28,600 15.5 13 C33-25B EL180UH090XE48B 8810243EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-25B EL195UH045XE36B 8810244EL16XC1-030-230A TXV 28,600 15.1 12.5 C33-25B EL195UH070XE36B 8810245EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-25B EL296UH045XE36B 8810246EL16XC1-030-230A TXV 28,600 15.1 12.5 C33-25B EL296UH070XE36B 8810247EL16XC1-030-230A TXV 28,600 15.5 12.5 C33-25B EL296UH070XV36B 8810248EL16XC1-030-230A TXV 28,600 16 13 C33-25B SL280UH090V36B 8810249EL16XC1-030-230A TXV 28,600 15.5 12.5 C33-25B SLP98UH070XV36B 8810251EL16XC1-030-230A TXV 27,600 14.5 12.5 C33-30A EL180UH045E36A 8810252EL16XC1-030-230A TXV 27,600 14.5 12.5 C33-30A EL180UH045XE36A 8810253EL16XC1-030-230A TXV 27,600 14.5 12.5 C33-30A SL280UH070V36A 8810254EL16XC1-030-230A TXV 27,600 14.5 12.5 C33-30A SL280UH070XV36A 8810255NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 28: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 28

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 27,600 15.1 12.5 C33-30B EL180UH070E36B 8810256EL16XC1-030-230A TXV 27,600 15.1 12.5 C33-30B EL180UH070XE36B 8810257EL16XC1-030-230A TXV 27,600 15.1 12.5 C33-30B EL180UH090E48B 8810258EL16XC1-030-230A TXV 27,600 15.1 12.5 C33-30B EL180UH090XE48B 8810259EL16XC1-030-230A TXV 27,400 14.5 12.2 C33-30B EL195UH045XE36B 8810260EL16XC1-030-230A TXV 27,600 14.5 12.2 C33-30B EL195UH070XE36B 8810261EL16XC1-030-230A TXV 27,400 14.5 12.2 C33-30B EL296UH045XE36B 8810263EL16XC1-030-230A TXV 27,600 14.5 12.2 C33-30B EL296UH070XE36B 8810264EL16XC1-030-230A TXV 27,600 14.5 12.5 C33-30B EL296UH070XV36B 8810265EL16XC1-030-230A TXV 27,800 15.1 12.5 C33-30B SL280UH090V36B 8810266EL16XC1-030-230A TXV 27,600 14.5 12.5 C33-30B SLP98UH070XV36B 8810267EL16XC1-030-230A TXV 27,600 15.1 12.5 C33-30C SLP98UH090XV36C 8810268EL16XC1-030-230A TXV 29,000 15.5 12.5 C33-31A EL180UH045E36A 8810269EL16XC1-030-230A TXV 29,000 15.5 12.5 C33-31A EL180UH045XE36A 8810270EL16XC1-030-230A TXV 29,000 16 13 C33-31A SL280UH070V36A 8810271EL16XC1-030-230A TXV 29,000 16 13 C33-31A SL280UH070XV36A 8810273EL16XC1-030-230A TXV 28,600 14.25 12.2 C33-31A 8810275EL16XC1-030-230A TXV 29,200 16 13 C33-31B EL180UH070E36B 8810276EL16XC1-030-230A TXV 29,200 16 13 C33-31B EL180UH070XE36B 8810277EL16XC1-030-230A TXV 29,200 16 13 C33-31B EL180UH090E48B 8810278EL16XC1-030-230A TXV 29,200 16 13 C33-31B EL180UH090XE48B 8810279EL16XC1-030-230A TXV 29,000 15.5 12.5 C33-31B EL195UH045XE36B 8810280EL16XC1-030-230A TXV 29,200 15.5 12.5 C33-31B EL195UH070XE36B 8810281EL16XC1-030-230A TXV 29,000 15.5 12.5 C33-31B EL296UH045XE36B 8810282EL16XC1-030-230A TXV 29,200 15.5 12.5 C33-31B EL296UH070XE36B 8810283EL16XC1-030-230A TXV 29,000 16 13 C33-31B EL296UH070XV36B 8810285EL16XC1-030-230A TXV 29,000 16 13 C33-31B SL280UH090V36B 8810286EL16XC1-030-230A TXV 29,000 16 13 C33-31B SLP98UH070XV36B 8810287EL16XC1-030-230A TXV 28,600 14.25 12.2 C33-31B 8810289EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-36A EL180UH045E36A 8810290EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-36A EL180UH045XE36A 8810291EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-36A SL280UH070V36A 8810292EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-36A SL280UH070XV36A 8810293EL16XC1-030-230A TXV 28,600 15.5 12.5 C33-36B EL180UH070E36B 8810294EL16XC1-030-230A TXV 28,600 15.5 12.5 C33-36B EL180UH070XE36B 8810295EL16XC1-030-230A TXV 28,600 15.5 13 C33-36B EL180UH090E48B 8810296EL16XC1-030-230A TXV 28,600 15.5 13 C33-36B EL180UH090XE48B 8810297EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-36B EL195UH045XE36B 8810298EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-36B EL195UH070XE36B 8810299EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-36B EL296UH045XE36B 8810300EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-36B EL296UH045XV36B 8810301EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-36B EL296UH070XE36B 8810302EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-36B EL296UH070XV36B 8810303EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-36B SL280UH090V36B 8810304EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-36B SLP98UH070XV36B 8810305EL16XC1-030-230A TXV 28,200 15.5 12.5 C33-36C EL195UH090XE48C 8810306EL16XC1-030-230A TXV 28,200 15.5 12.5 C33-36C EL296UH090XE48C 8810307EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-36C EL296UH090XV36C 8810308EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-36C SLP98UH090XV36C 8810309NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 29: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 29

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 29,200 16 13 C33-38A EL180UH045E36A 8810310EL16XC1-030-230A TXV 29,200 16 13 C33-38A EL180UH045XE36A 8810311EL16XC1-030-230A TXV 29,200 16 13 C33-38A SL280UH070V36A 8810312EL16XC1-030-230A TXV 29,200 16 13 C33-38A SL280UH070XV36A 8810313EL16XC1-030-230A TXV 28,800 14.5 12.2 C33-38A 8810315EL16XC1-030-230A TXV 29,400 16 13 C33-38B EL180UH070E36B 8810316EL16XC1-030-230A TXV 29,400 16 13 C33-38B EL180UH070XE36B 8810317EL16XC1-030-230A TXV 29,400 16 13 C33-38B EL180UH090E48B 8810318EL16XC1-030-230A TXV 29,400 16 13 C33-38B EL180UH090XE48B 8810319EL16XC1-030-230A TXV 29,200 15.5 13 C33-38B EL195UH045XE36B 8810320EL16XC1-030-230A TXV 29,400 15.5 13 C33-38B EL195UH070XE36B 8810321EL16XC1-030-230A TXV 29,200 15.5 13 C33-38B EL296UH045XE36B 8810322EL16XC1-030-230A TXV 29,400 15.5 13 C33-38B EL296UH045XV36B 8810323EL16XC1-030-230A TXV 29,400 15.5 13 C33-38B EL296UH070XE36B 8810324EL16XC1-030-230A TXV 29,400 16 13 C33-38B EL296UH070XV36B 8810325EL16XC1-030-230A TXV 29,400 16 13 C33-38B SL280UH090V36B 8810326EL16XC1-030-230A TXV 29,400 16 13 C33-38B SLP98UH070XV36B 8810327EL16XC1-030-230A TXV 28,800 14.5 12.2 C33-38B 8810329EL16XC1-030-230A TXV 28,600 15.5 12.5 C33-42 EL180UH070E36B 8810330EL16XC1-030-230A TXV 28,600 15.5 12.5 C33-42 EL180UH070XE36B 8810331EL16XC1-030-230A TXV 28,600 15.5 13 C33-42 EL180UH090E48B 8810332EL16XC1-030-230A TXV 28,600 15.5 13 C33-42 EL180UH090XE48B 8810333EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-42 EL195UH045XE36B 8810334EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-42 EL195UH070XE36B 8810335EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-42 EL296UH045XE36B 8810336EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-42 EL296UH045XV36B 8810337EL16XC1-030-230A TXV 28,400 15.1 12.5 C33-42 EL296UH070XE36B 8810338EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-42 EL296UH070XV36B 8810339EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-42 SL280UH090V36B 8810340EL16XC1-030-230A TXV 28,400 15.5 12.5 C33-42 SLP98UH070XV36B 8810341EL16XC1-030-230A TXV 29,600 16 13 C33-43B EL180UH070E36B 8810342EL16XC1-030-230A TXV 29,600 16 13 C33-43B EL180UH070XE36B 8810343EL16XC1-030-230A TXV 29,600 16 13 C33-43B EL180UH090E48B 8810344EL16XC1-030-230A TXV 29,600 16 13 C33-43B EL180UH090XE48B 8810345EL16XC1-030-230A TXV 29,400 16 13 C33-43B EL195UH045XE36B 8810346EL16XC1-030-230A TXV 29,600 16 13 C33-43B EL195UH070XE36B 8810347EL16XC1-030-230A TXV 29,400 16 13 C33-43B EL296UH045XE36B 8810348EL16XC1-030-230A TXV 29,400 15.5 13 C33-43B EL296UH045XV36B 8810349EL16XC1-030-230A TXV 29,600 16 13 C33-43B EL296UH070XE36B 8810350EL16XC1-030-230A TXV 29,400 16 13 C33-43B EL296UH070XV36B 8810351EL16XC1-030-230A TXV 29,400 16 13 C33-43B SL280UH090V36B 8810352EL16XC1-030-230A TXV 29,400 16 13 C33-43B SLP98UH070XV36B 8810353EL16XC1-030-230A TXV 28,800 14.5 12.2 C33-43B 8810355EL16XC1-030-230A TXV 29,400 16 13 C33-43C EL195UH090XE48C 8810356EL16XC1-030-230A TXV 29,400 16 13 C33-43C EL296UH090XE48C 8810357EL16XC1-030-230A TXV 29,400 16 13 C33-43C EL296UH090XV36C 8810358EL16XC1-030-230A TXV 29,200 16 13 C33-43C EL296UH090XV48C 8810360EL16XC1-030-230A TXV 29,400 16 13 C33-43C SLP98UH090XV36C 8810361EL16XC1-030-230A TXV 29,200 16 13 C33-43C SLP98UH090XV48C 8810362NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 30: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 30

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 28,800 14.5 12.2 C33-43C 8810363EL16XC1-030-230A TXV 28,600 15.5 12.5 C35-24A EL180UH045E36A 8810364EL16XC1-030-230A TXV 28,600 15.5 12.5 C35-24A EL180UH045XE36A 8810365EL16XC1-030-230A TXV 28,600 15.5 12.5 C35-24A SL280UH070V36A 8810366EL16XC1-030-230A TXV 28,600 15.5 12.5 C35-24A SL280UH070XV36A 8810368EL16XC1-030-230A TXV 28,600 15.5 13 C35-24B EL180UH070E36B 8810369EL16XC1-030-230A TXV 28,600 15.5 13 C35-24B EL180UH070XE36B 8810370EL16XC1-030-230A TXV 28,600 15.5 13 C35-24B EL180UH090E48B 8810371EL16XC1-030-230A TXV 28,600 15.5 13 C35-24B EL180UH090XE48B 8810372EL16XC1-030-230A TXV 28,600 15.1 12.5 C35-24B EL195UH045XE36B 8810373EL16XC1-030-230A TXV 28,800 15.1 12.5 C35-24B EL195UH070XE36B 8810374EL16XC1-030-230A TXV 28,600 15.1 12.5 C35-24B EL296UH045XE36B 8810376EL16XC1-030-230A TXV 28,800 15.1 12.5 C35-24B EL296UH070XE36B 8810377EL16XC1-030-230A TXV 28,600 15.5 12.5 C35-24B EL296UH070XV36B 8810378EL16XC1-030-230A TXV 28,600 16 13 C35-24B SL280UH090V36B 8810379EL16XC1-030-230A TXV 28,600 15.5 12.5 C35-24B SLP98UH070XV36B 8810380EL16XC1-030-230A TXV 28,400 15.5 12.5 C35-30/36A EL180UH045E36A 8810381EL16XC1-030-230A TXV 28,400 15.5 12.5 C35-30/36A EL180UH045XE36A 8810382EL16XC1-030-230A TXV 28,400 15.5 12.5 C35-30/36A SL280UH070V36A 8810383EL16XC1-030-230A TXV 28,400 15.5 12.5 C35-30/36A SL280UH070XV36A 8810384EL16XC1-030-230A TXV 28,600 15.5 13 C35-30/36B EL180UH070E36B 8810385EL16XC1-030-230A TXV 28,600 15.5 13 C35-30/36B EL180UH070XE36B 8810386EL16XC1-030-230A TXV 28,600 16 13 C35-30/36B EL180UH090E48B 8810387EL16XC1-030-230A TXV 28,600 16 13 C35-30/36B EL180UH090XE48B 8810388EL16XC1-030-230A TXV 28,600 15.1 12.5 C35-30/36B EL195UH045XE36B 8810389EL16XC1-030-230A TXV 28,600 15.1 12.5 C35-30/36B EL195UH070XE36B 8810390EL16XC1-030-230A TXV 28,600 15.1 12.5 C35-30/36B EL296UH045XE36B 8810391EL16XC1-030-230A TXV 28,600 15.1 12.5 C35-30/36B EL296UH045XV36B 8810392EL16XC1-030-230A TXV 28,600 15.1 12.5 C35-30/36B EL296UH070XE36B 8810393EL16XC1-030-230A TXV 28,600 15.5 12.5 C35-30/36B EL296UH070XV36B 8810394EL16XC1-030-230A TXV 28,600 15.5 13 C35-30/36B SL280UH090V36B 8810395EL16XC1-030-230A TXV 28,600 15.5 12.5 C35-30/36B SLP98UH070XV36B 8810396EL16XC1-030-230A TXV 28,400 15.5 12.5 C35-30/36C EL195UH090XE48C 8810397EL16XC1-030-230A TXV 28,400 15.5 12.5 C35-30/36C EL296UH090XE48C 8810398EL16XC1-030-230A TXV 28,400 15.5 13 C35-30/36C EL296UH090XV36C 8810399EL16XC1-030-230A TXV 28,400 15.5 13 C35-30/36C SLP98UH090XV36C 8810400EL16XC1-030-230A TXV 29,200 15.5 13 C35-30A EL180UH045E36A 8810401EL16XC1-030-230A TXV 29,200 15.5 13 C35-30A EL180UH045XE36A 8810402EL16XC1-030-230A TXV 29,200 16 13 C35-30A SL280UH070V36A 8810403EL16XC1-030-230A TXV 29,200 16 13 C35-30A SL280UH070XV36A 8810404EL16XC1-030-230A TXV 28,600 14.25 12.2 C35-30A 8810405EL16XC1-030-230A TXV 29,200 16 13 C35-30B EL180UH070E36B 8810406EL16XC1-030-230A TXV 29,200 16 13 C35-30B EL180UH070XE36B 8810407EL16XC1-030-230A TXV 29,200 16 13 C35-30B EL180UH090E48B 8810408EL16XC1-030-230A TXV 29,200 16 13 C35-30B EL180UH090XE48B 8810409EL16XC1-030-230A TXV 29,200 15.5 12.5 C35-30B EL195UH045XE36B 8810410EL16XC1-030-230A TXV 29,400 15.5 12.5 C35-30B EL195UH070XE36B 8810411EL16XC1-030-230A TXV 29,200 15.5 12.5 C35-30B EL296UH045XE36B 8810412EL16XC1-030-230A TXV 29,400 15.5 12.5 C35-30B EL296UH070XE36B 8810413NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 31: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 31

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 29,200 16 13 C35-30B EL296UH070XV36B 8810414EL16XC1-030-230A TXV 29,200 16 13 C35-30B SL280UH090V36B 8810415EL16XC1-030-230A TXV 29,200 16 13 C35-30B SLP98UH070XV36B 8810416EL16XC1-030-230A TXV 29,400 16 13 C35-36A EL180UH045E36A 8810417EL16XC1-030-230A TXV 29,400 16 13 C35-36A EL180UH045XE36A 8810418EL16XC1-030-230A TXV 29,400 16 13 C35-36A SL280UH070V36A 8810419EL16XC1-030-230A TXV 29,400 16 13 C35-36A SL280UH070XV36A 8810420EL16XC1-030-230A TXV 28,800 14.5 12.2 C35-36A 8810421EL16XC1-030-230A TXV 29,600 16 13 C35-36B EL180UH070E36B 8810422EL16XC1-030-230A TXV 29,600 16 13 C35-36B EL180UH070XE36B 8810423EL16XC1-030-230A TXV 29,600 16 13 C35-36B EL180UH090E48B 8810424EL16XC1-030-230A TXV 29,600 16 13 C35-36B EL180UH090XE48B 8810425EL16XC1-030-230A TXV 29,400 15.5 13 C35-36B EL195UH045XE36B 8810426EL16XC1-030-230A TXV 29,600 16 13 C35-36B EL195UH070XE36B 8810427EL16XC1-030-230A TXV 29,400 15.5 13 C35-36B EL296UH045XE36B 8810428EL16XC1-030-230A TXV 29,400 15.5 13 C35-36B EL296UH045XV36B 8810429EL16XC1-030-230A TXV 29,600 16 13 C35-36B EL296UH070XE36B 8810430EL16XC1-030-230A TXV 29,400 16 13 C35-36B EL296UH070XV36B 8810431EL16XC1-030-230A TXV 29,400 16 13 C35-36B SL280UH090V36B 8810432EL16XC1-030-230A TXV 29,400 16 13 C35-36B SLP98UH070XV36B 8810433EL16XC1-030-230A TXV 28,800 14.5 12.2 C35-36B 8810434EL16XC1-030-230A TXV 29,600 16 13 C35-48B EL180UH070E36B 8810435EL16XC1-030-230A TXV 29,600 16 13 C35-48B EL180UH070XE36B 8810436EL16XC1-030-230A TXV 29,600 16 13 C35-48B EL180UH090E48B 8810437EL16XC1-030-230A TXV 29,600 16 13 C35-48B EL180UH090XE48B 8810438EL16XC1-030-230A TXV 29,400 16 13 C35-48B EL195UH045XE36B 8810439EL16XC1-030-230A TXV 29,600 16 13 C35-48B EL195UH070XE36B 8810440EL16XC1-030-230A TXV 29,400 16 13 C35-48B EL296UH045XE36B 8810441EL16XC1-030-230A TXV 29,400 15.5 13 C35-48B EL296UH045XV36B 8810442EL16XC1-030-230A TXV 29,600 16 13 C35-48B EL296UH070XE36B 8810443EL16XC1-030-230A TXV 29,400 16 13 C35-48B EL296UH070XV36B 8810444EL16XC1-030-230A TXV 29,400 16 13 C35-48B SL280UH090V36B 8810445EL16XC1-030-230A TXV 29,400 16 13 C35-48B SLP98UH070XV36B 8810446EL16XC1-030-230A TXV 29,000 14.5 12.2 C35-48B 8810447EL16XC1-030-230A TXV 29,400 16 13 C35-48C EL195UH090XE48C 8810448EL16XC1-030-230A TXV 29,400 16 13 C35-48C EL296UH090XE48C 8810449EL16XC1-030-230A TXV 29,400 16 13 C35-48C EL296UH090XV36C 8810450EL16XC1-030-230A TXV 29,200 16 13 C35-48C EL296UH090XV48C 8810451EL16XC1-030-230A TXV 29,400 16 13 C35-48C SLP98UH090XV36C 8810452EL16XC1-030-230A TXV 29,200 16 13 C35-48C SLP98UH090XV48C 8810453EL16XC1-030-230A TXV 29,000 14.5 12.2 C35-48C 8810454EL16XC1-030-230A TXV 29,000 16 13 CBA27UHE-030 10259405EL16XC1-030-230A TXV 29,000 16 13 CBA27UHE-036 10259406EL16XC1-030-230A TXV 28,400 14.25 12.2 CBX25UH-036 8810455EL16XC1-030-230A TXV 28,600 15.1 12.5 CBX25UHV-030 8810456EL16XC1-030-230A TXV 28,800 15.5 12.5 CBX25UHV-036 8810457EL16XC1-030-230A TXV 29,000 16 13 CBX27UH-030 8810458EL16XC1-030-230A TXV 29,000 16 13 CBX27UH-036 8810459EL16XC1-030-230A TXV 28,400 14.5 12.5 CBX32M-030 8810460NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 32: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 32

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 28,600 14.5 12.5 CBX32M-036 8810461EL16XC1-030-230A TXV 28,200 15 12.5 CBX32MV-024/030 10267537EL16XC1-030-230A TXV 28,800 15.5 12.5 CBX32MV-036 8810462EL16XC1-030-230A TXV 28,800 15.5 12.5 CBX40UHV-030 8810463EL16XC1-030-230A TXV 28,800 15.5 13 CBX40UHV-036 8810464EL16XC1-030-230A TXV 27,000 14.5 12.5 CH23-31 EL180UH070E36B 8810465EL16XC1-030-230A TXV 27,000 14.5 12.5 CH23-31 EL180UH070XE36B 8810466EL16XC1-030-230A TXV 27,000 14.5 12.2 CH23-31 EL296UH045XV36B 8810467EL16XC1-030-230A TXV 27,000 15.1 12.5 CH23-31 EL296UH070XV36B 8810468EL16XC1-030-230A TXV 26,800 15.1 12.5 CH23-31 SL280UH090V36B 8810469EL16XC1-030-230A TXV 27,000 15.1 12.5 CH23-31 SLP98UH070XV36B 8810470EL16XC1-030-230A TXV 28,600 15.5 12.5 CH23-41 EL180UH045E36A 8810471EL16XC1-030-230A TXV 28,600 15.5 12.5 CH23-41 EL180UH045XE36A 8810472EL16XC1-030-230A TXV 28,600 15.5 13 CH23-41 EL180UH070E36B 8810473EL16XC1-030-230A TXV 28,600 15.5 13 CH23-41 EL180UH070XE36B 8810474EL16XC1-030-230A TXV 28,600 16 13 CH23-41 EL180UH090E48B 8810475EL16XC1-030-230A TXV 28,600 16 13 CH23-41 EL180UH090XE48B 8810476EL16XC1-030-230A TXV 28,600 15.5 12.5 CH23-41 EL195UH045XE36B 8810477EL16XC1-030-230A TXV 28,600 15.1 12.5 CH23-41 EL195UH070XE36B 8810478EL16XC1-030-230A TXV 28,600 15.5 12.5 CH23-41 EL296UH045XE36B 8810479EL16XC1-030-230A TXV 28,400 15.5 12.5 CH23-41 EL296UH045XV36B 8810480EL16XC1-030-230A TXV 28,600 15.1 12.5 CH23-41 EL296UH070XE36B 8810481EL16XC1-030-230A TXV 28,600 15.5 12.5 CH23-41 EL296UH070XV36B 8810482EL16XC1-030-230A TXV 28,800 16 13 CH23-41 SL280UH090V36B 8810483EL16XC1-030-230A TXV 28,600 15.5 12.5 CH23-41 SLP98UH070XV36B 8810484EL16XC1-030-230A TXV 27,800 15.1 12.5 CH33-19 EL180UH045E36A 8810485EL16XC1-030-230A TXV 27,800 15.1 12.5 CH33-19 EL180UH045XE36A 8810486EL16XC1-030-230A TXV 27,800 15.1 12.5 CH33-19 SL280UH070V36A 8810487EL16XC1-030-230A TXV 27,800 15.1 12.5 CH33-19 SL280UH070XV36A 8810488EL16XC1-030-230A TXV 27,600 14.5 12.5 CH33-24/30 EL180UH045E36A 8810489EL16XC1-030-230A TXV 27,600 14.5 12.5 CH33-24/30 EL180UH045XE36A 8810490EL16XC1-030-230A TXV 27,800 15.1 12.5 CH33-24/30 SL280UH070V36A 8810491EL16XC1-030-230A TXV 27,800 15.1 12.5 CH33-24/30 SL280UH070XV36A 8810492EL16XC1-030-230A TXV 28,400 15.5 12.5 CH33-25A EL180UH045E36A 8810493EL16XC1-030-230A TXV 28,400 15.5 12.5 CH33-25A EL180UH045XE36A 8810494EL16XC1-030-230A TXV 28,600 15.5 12.5 CH33-25A SL280UH070V36A 8810495EL16XC1-030-230A TXV 28,600 15.5 12.5 CH33-25A SL280UH070XV36A 8810496EL16XC1-030-230A TXV 28,600 15.5 12.5 CH33-25B EL180UH070E36B 8810497EL16XC1-030-230A TXV 28,600 15.5 12.5 CH33-25B EL180UH070XE36B 8810498EL16XC1-030-230A TXV 28,600 15.5 13 CH33-25B EL180UH090E48B 8810499EL16XC1-030-230A TXV 28,600 15.5 13 CH33-25B EL180UH090XE48B 8810500EL16XC1-030-230A TXV 28,400 15.1 12.5 CH33-25B EL195UH045XE36B 8810501EL16XC1-030-230A TXV 28,600 15.1 12.5 CH33-25B EL195UH070XE36B 8810502EL16XC1-030-230A TXV 28,400 15.1 12.5 CH33-25B EL296UH045XE36B 8810503EL16XC1-030-230A TXV 28,400 15.1 12.5 CH33-25B EL296UH045XV36B 8810504EL16XC1-030-230A TXV 28,600 15.1 12.5 CH33-25B EL296UH070XE36B 8810505EL16XC1-030-230A TXV 28,400 15.5 12.5 CH33-25B EL296UH070XV36B 8810506EL16XC1-030-230A TXV 28,600 16 13 CH33-25B SL280UH090V36B 8810507EL16XC1-030-230A TXV 28,400 15.5 12.5 CH33-25B SLP98UH070XV36B 8810508NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 33: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 33

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 29,000 15.5 12.5 CH33-31A EL180UH045E36A 8810509EL16XC1-030-230A TXV 29,000 15.5 12.5 CH33-31A EL180UH045XE36A 8810510EL16XC1-030-230A TXV 29,000 15.5 13 CH33-31A SL280UH070V36A 8810511EL16XC1-030-230A TXV 29,000 15.5 13 CH33-31A SL280UH070XV36A 8810512EL16XC1-030-230A TXV 28,600 14.25 12.2 CH33-31A 8810514EL16XC1-030-230A TXV 29,400 16 13 CH33-31B EL180UH070E36B 8810515EL16XC1-030-230A TXV 29,400 16 13 CH33-31B EL180UH070XE36B 8810516EL16XC1-030-230A TXV 29,400 16 13 CH33-31B EL180UH090E48B 8810517EL16XC1-030-230A TXV 29,400 16 13 CH33-31B EL180UH090XE48B 8810518EL16XC1-030-230A TXV 29,200 15.5 13 CH33-31B EL195UH045XE36B 8810519EL16XC1-030-230A TXV 29,400 15.5 13 CH33-31B EL195UH070XE36B 8810520EL16XC1-030-230A TXV 29,200 15.5 13 CH33-31B EL296UH045XE36B 8810521EL16XC1-030-230A TXV 29,200 15.5 13 CH33-31B EL296UH045XV36B 8810522EL16XC1-030-230A TXV 29,400 15.5 13 CH33-31B EL296UH070XE36B 8810523EL16XC1-030-230A TXV 29,200 16 13 CH33-31B EL296UH070XV36B 8810524EL16XC1-030-230A TXV 29,200 16 13 CH33-31B SL280UH090V36B 8810525EL16XC1-030-230A TXV 29,200 16 13 CH33-31B SLP98UH070XV36B 8810526EL16XC1-030-230A TXV 28,800 14.5 12.2 CH33-31B 8810528EL16XC1-030-230A TXV 28,200 15.1 12.5 CH33-36A EL180UH045E36A 8810529EL16XC1-030-230A TXV 28,200 15.1 12.5 CH33-36A EL180UH045XE36A 8810530EL16XC1-030-230A TXV 28,200 15.1 12.5 CH33-36A SL280UH070V36A 8810531EL16XC1-030-230A TXV 28,200 15.1 12.5 CH33-36A SL280UH070XV36A 8810532EL16XC1-030-230A TXV 28,400 15.5 12.5 CH33-36B EL180UH070E36B 8810533EL16XC1-030-230A TXV 28,400 15.5 12.5 CH33-36B EL180UH070XE36B 8810534EL16XC1-030-230A TXV 28,400 15.5 13 CH33-36B EL180UH090E48B 8810535EL16XC1-030-230A TXV 28,400 15.5 13 CH33-36B EL180UH090XE48B 8810536EL16XC1-030-230A TXV 28,400 15.1 12.5 CH33-36B EL195UH045XE36B 8810537EL16XC1-030-230A TXV 28,400 15.1 12.5 CH33-36B EL195UH070XE36B 8810538EL16XC1-030-230A TXV 28,400 15.1 12.5 CH33-36B EL296UH045XE36B 8810539EL16XC1-030-230A TXV 28,400 15.1 12.5 CH33-36B EL296UH045XV36B 8810540EL16XC1-030-230A TXV 28,400 15.1 12.5 CH33-36B EL296UH070XE36B 8810541EL16XC1-030-230A TXV 28,400 15.5 12.5 CH33-36B SL280UH090V36B 8810542EL16XC1-030-230A TXV 28,400 15.5 12.5 CH33-36B SLP98UH070XV36B 8810543EL16XC1-030-230A TXV 28,600 16 13 CH33-36C EL195UH090XE48C 8810544EL16XC1-030-230A TXV 28,600 16 13 CH33-36C EL296UH090XE48C 8810545EL16XC1-030-230A TXV 28,600 16 13 CH33-36C EL296UH090XV36C 8810546EL16XC1-030-230A TXV 28,600 16 13 CH33-36C SLP98UH090XV36C 8810547EL16XC1-030-230A TXV 29,200 16 13 CH33-42 EL180UH070E36B 8810548EL16XC1-030-230A TXV 29,200 16 13 CH33-42 EL180UH070XE36B 8810549EL16XC1-030-230A TXV 29,200 16 13 CH33-42 EL180UH090E48B 8810550EL16XC1-030-230A TXV 29,200 16 13 CH33-42 EL180UH090XE48B 8810551EL16XC1-030-230A TXV 29,000 15.5 12.5 CH33-42 EL195UH045XE36B 8810552EL16XC1-030-230A TXV 29,200 15.5 12.5 CH33-42 EL195UH070XE36B 8810553EL16XC1-030-230A TXV 29,000 15.5 12.5 CH33-42 EL296UH045XE36B 8810554EL16XC1-030-230A TXV 29,000 15.5 12.5 CH33-42 EL296UH045XV36B 8810555EL16XC1-030-230A TXV 29,200 15.5 12.5 CH33-42 EL296UH070XE36B 8810556EL16XC1-030-230A TXV 29,000 15.5 13 CH33-42 EL296UH070XV36B 8810557EL16XC1-030-230A TXV 29,000 15.5 13 CH33-42 SLP98UH070XV36B 8810558EL16XC1-030-230A TXV 29,600 16 13 CH33-43B EL180UH070E36B 8810559NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 34: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 34

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 29,600 16 13 CH33-43B EL180UH070XE36B 8810560EL16XC1-030-230A TXV 29,600 16 13 CH33-43B EL180UH090E48B 8810561EL16XC1-030-230A TXV 29,600 16 13 CH33-43B EL180UH090XE48B 8810562EL16XC1-030-230A TXV 29,400 16 13 CH33-43B EL195UH045XE36B 8810563EL16XC1-030-230A TXV 29,600 16 13 CH33-43B EL195UH070XE36B 8810564EL16XC1-030-230A TXV 29,400 16 13 CH33-43B EL296UH045XE36B 8810565EL16XC1-030-230A TXV 29,600 16 13 CH33-43B EL296UH045XV36B 8810566EL16XC1-030-230A TXV 29,600 16 13 CH33-43B EL296UH070XE36B 8810567EL16XC1-030-230A TXV 29,600 16 13 CH33-43B EL296UH070XV36B 8810568EL16XC1-030-230A TXV 29,600 16 13 CH33-43B SL280UH090V36B 8810569EL16XC1-030-230A TXV 29,600 16 13 CH33-43B SLP98UH070XV36B 8810570EL16XC1-030-230A TXV 29,000 14.5 12.2 CH33-43B 8810572EL16XC1-030-230A TXV 29,400 16 13 CH33-43C EL195UH090XE48C 8810573EL16XC1-030-230A TXV 29,400 16 13 CH33-43C EL296UH090XE48C 8810574EL16XC1-030-230A TXV 29,400 16 13 CH33-43C EL296UH090XV36C 8810575EL16XC1-030-230A TXV 29,400 16 13 CH33-43C SLP98UH090XV36C 8810576EL16XC1-030-230A TXV 29,000 14.5 12.2 CH33-43C 8810577EL16XC1-030-230A TXV 28,600 15.5 13 CH35-24B EL180UH070E36B 8810578EL16XC1-030-230A TXV 29,000 15.5 12.5 CH35-30A EL180UH045E36A 8810579EL16XC1-030-230A TXV 29,000 15.5 12.5 CH35-30A EL180UH045XE36A 8810580EL16XC1-030-230A TXV 29,200 15.5 13 CH35-30A SL280UH070V36A 8810581EL16XC1-030-230A TXV 29,200 15.5 13 CH35-30A SL280UH070XV36A 8810582EL16XC1-030-230A TXV 28,800 14.5 12.2 CH35-30A 8810583EL16XC1-030-230A TXV 29,400 16 13 CH35-30B EL180UH070E36B 8810584EL16XC1-030-230A TXV 29,400 16 13 CH35-30B EL180UH070XE36B 8810585EL16XC1-030-230A TXV 29,400 16 13 CH35-30B EL180UH090E48B 8810586EL16XC1-030-230A TXV 29,400 16 13 CH35-30B EL180UH090XE48B 8810587EL16XC1-030-230A TXV 29,400 15.5 13 CH35-30B EL195UH045XE36B 8810588EL16XC1-030-230A TXV 29,600 15.5 13 CH35-30B EL195UH070XE36B 8810589EL16XC1-030-230A TXV 29,400 15.5 13 CH35-30B EL296UH045XE36B 8810590EL16XC1-030-230A TXV 29,400 15.5 13 CH35-30B EL296UH045XV36B 8810591EL16XC1-030-230A TXV 29,600 15.5 13 CH35-30B EL296UH070XE36B 8810592EL16XC1-030-230A TXV 29,400 16 13 CH35-30B EL296UH070XV36B 8810593EL16XC1-030-230A TXV 29,400 16 13 CH35-30B SL280UH090V36B 8810594EL16XC1-030-230A TXV 29,400 16 13 CH35-30B SLP98UH070XV36B 8810595EL16XC1-030-230A TXV 28,800 14.5 12.2 CH35-30B 8810596EL16XC1-030-230A TXV 28,200 15.1 12.5 CH35-36A EL180UH045E36A 8810597EL16XC1-030-230A TXV 28,200 15.1 12.5 CH35-36A EL180UH045XE36A 8810598EL16XC1-030-230A TXV 28,400 15.1 12.5 CH35-36A SL280UH070V36A 8810599EL16XC1-030-230A TXV 28,400 15.1 12.5 CH35-36A SL280UH070XV36A 8810600EL16XC1-030-230A TXV 28,600 15.5 13 CH35-36B EL180UH070E36B 8810601EL16XC1-030-230A TXV 28,600 15.5 13 CH35-36B EL180UH070XE36B 8810602EL16XC1-030-230A TXV 28,600 16 13 CH35-36B EL180UH090E48B 8810603EL16XC1-030-230A TXV 28,600 16 13 CH35-36B EL180UH090XE48B 8810604EL16XC1-030-230A TXV 28,400 15.1 12.5 CH35-36B EL195UH045XE36B 8810605EL16XC1-030-230A TXV 28,600 15.1 12.5 CH35-36B EL195UH070XE36B 8810606EL16XC1-030-230A TXV 28,400 15.1 12.5 CH35-36B EL296UH045XE36B 8810607EL16XC1-030-230A TXV 28,400 15.1 12.5 CH35-36B EL296UH045XV36B 8810608EL16XC1-030-230A TXV 28,600 15.1 12.5 CH35-36B EL296UH070XE36B 8810609NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 35: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 35

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 28,600 15.5 12.5 CH35-36B EL296UH070XV36B 8810610EL16XC1-030-230A TXV 28,600 15.5 12.5 CH35-36B SLP98UH070XV36B 8810611EL16XC1-030-230A TXV 28,600 16 13 CH35-36C EL195UH090XE48C 8810612EL16XC1-030-230A TXV 28,600 16 13 CH35-36C EL296UH090XE48C 8810613EL16XC1-030-230A TXV 28,600 16 13 CH35-36C EL296UH090XV36C 8810614EL16XC1-030-230A TXV 28,600 16 13 CH35-36C SLP98UH090XV36C 8810615EL16XC1-030-230A TXV 30,000 16 13 CH35-42B EL180UH070E36B 8810616EL16XC1-030-230A TXV 30,000 16 13 CH35-42B EL180UH070XE36B 8810617EL16XC1-030-230A TXV 30,000 16 13 CH35-42B EL180UH090E48B 8810618EL16XC1-030-230A TXV 30,000 16 13 CH35-42B EL180UH090XE48B 8810619EL16XC1-030-230A TXV 29,800 16 13 CH35-42B EL195UH045XE36B 8810620EL16XC1-030-230A TXV 30,000 16 13 CH35-42B EL195UH070XE36B 8810621EL16XC1-030-230A TXV 29,800 16 13 CH35-42B EL296UH045XE36B 8810622EL16XC1-030-230A TXV 29,800 16 13 CH35-42B EL296UH045XV36B 8810623EL16XC1-030-230A TXV 30,000 16 13 CH35-42B EL296UH070XE36B 8810624EL16XC1-030-230A TXV 29,800 16 13 CH35-42B EL296UH070XV36B 8810625EL16XC1-030-230A TXV 29,800 16 13 CH35-42B SL280UH090V36B 8810626EL16XC1-030-230A TXV 29,800 16 13 CH35-42B SLP98UH070XV36B 8810627EL16XC1-030-230A TXV 29,400 14.5 12.5 CH35-42B 8810628EL16XC1-030-230A TXV 29,600 16 13 CH35-42C EL195UH090XE48C 8810629EL16XC1-030-230A TXV 29,600 16 13 CH35-42C EL296UH090XE48C 8810630EL16XC1-030-230A TXV 29,400 16 13 CH35-42C EL296UH090XV36C 8810631EL16XC1-030-230A TXV 29,400 16 13 CH35-42C SLP98UH090XV36C 8810632EL16XC1-030-230A TXV 29,000 14.5 12.2 CH35-42C 8810633EL16XC1-030-230A TXV 27,000 14.5 12.2 CR33-24A EL180DF045E36A 8810634EL16XC1-030-230A TXV 26,800 14.5 12.2 CR33-24B EL180DF070E36B 8810635EL16XC1-030-230A TXV 27,000 14.25 12.2 CR33-24B EL296DF045XV36B 8810636EL16XC1-030-230A TXV 26,800 14.25 12.2 CR33-24B SL280DF090V48B 8810637EL16XC1-030-230A TXV 28,800 15.5 12.5 CR33-30/36A EL180DF045E36A 8810638EL16XC1-030-230A TXV 28,800 15.5 12.5 CR33-30/36A SL280DF070V36A 8810639EL16XC1-030-230A TXV 28,800 16 13 CR33-30/36B EL180DF070E36B 8810640EL16XC1-030-230A TXV 28,600 16 13 CR33-30/36B EL180DF090E48B 8810641EL16XC1-030-230A TXV 28,600 15.1 12.5 CR33-30/36B EL195DF045XE36B 8810642EL16XC1-030-230A TXV 28,800 15.5 12.5 CR33-30/36B EL195DF070XE48B 8810643EL16XC1-030-230A TXV 28,600 15.1 12.5 CR33-30/36B EL296DF045XE36B 8810644EL16XC1-030-230A TXV 28,800 15.5 12.5 CR33-30/36B EL296DF045XV36B 8810645EL16XC1-030-230A TXV 28,800 15.5 12.5 CR33-30/36B EL296DF070XE48B 8810646EL16XC1-030-230A TXV 28,600 15.5 12.5 CR33-30/36B EL296DF070XV48B 8810647EL16XC1-030-230A TXV 28,400 15.5 12.5 CR33-30/36B SL280DF090V48B 8810648EL16XC1-030-230A TXV 28,600 15.5 12.5 CR33-30/36B SLP98DF070XV36B 8810649EL16XC1-030-230A TXV 28,800 16 13 CR33-30/36C SLP98DF090XV36C 8810650EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-25A EL180UH045E36A 8810651EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-25A EL180UH045XE36A 8810652EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-25A SL280UH070V36A 8810653EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-25A SL280UH070XV36A 8810654EL16XC1-030-230A TXV 28,600 15.5 12.5 CX34-25B EL180UH070E36B 8810655EL16XC1-030-230A TXV 28,600 15.5 12.5 CX34-25B EL180UH070XE36B 8810656EL16XC1-030-230A TXV 28,600 15.5 13 CX34-25B EL180UH090E48B 8810657EL16XC1-030-230A TXV 28,600 15.5 13 CX34-25B EL180UH090XE48B 8810658NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 36: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 36

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-25B EL195UH045XE36B 8810659EL16XC1-030-230A TXV 28,600 15.1 12.5 CX34-25B EL195UH070XE36B 8810660EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-25B EL296UH045XE36B 8810661EL16XC1-030-230A TXV 28,600 15.5 12.5 CX34-25B EL296UH045XV36B 8810662EL16XC1-030-230A TXV 28,600 15.1 12.5 CX34-25B EL296UH070XE36B 8810663EL16XC1-030-230A TXV 28,600 15.5 12.5 CX34-25B EL296UH070XV36B 8810664EL16XC1-030-230A TXV 28,600 16 13 CX34-25B SL280UH090V36B 8810665EL16XC1-030-230A TXV 28,600 15.5 12.5 CX34-25B SLP98UH070XV36B 8810666EL16XC1-030-230A TXV 27,600 14.5 12.5 CX34-30A EL180UH045E36A 8810667EL16XC1-030-230A TXV 27,600 14.5 12.5 CX34-30A EL180UH045XE36A 8810668EL16XC1-030-230A TXV 27,600 14.5 12.5 CX34-30A SL280UH070V36A 8810669EL16XC1-030-230A TXV 27,600 14.5 12.5 CX34-30A SL280UH070XV36A 8810670EL16XC1-030-230A TXV 27,600 15.1 12.5 CX34-30B EL180UH070E36B 8810671EL16XC1-030-230A TXV 27,600 15.1 12.5 CX34-30B EL180UH070XE36B 8810672EL16XC1-030-230A TXV 27,600 15.1 12.5 CX34-30B EL180UH090E48B 8810673EL16XC1-030-230A TXV 27,600 15.1 12.5 CX34-30B EL180UH090XE48B 8810674EL16XC1-030-230A TXV 27,400 14.5 12.2 CX34-30B EL195UH045XE36B 8810675EL16XC1-030-230A TXV 27,600 14.5 12.2 CX34-30B EL195UH070XE36B 8810676EL16XC1-030-230A TXV 27,400 14.5 12.2 CX34-30B EL296UH045XE36B 8810677EL16XC1-030-230A TXV 27,600 14.5 12.5 CX34-30B EL296UH045XV36B 8810678EL16XC1-030-230A TXV 27,600 14.5 12.2 CX34-30B EL296UH070XE36B 8810679EL16XC1-030-230A TXV 27,600 14.5 12.5 CX34-30B EL296UH070XV36B 8810680EL16XC1-030-230A TXV 27,800 15.1 12.5 CX34-30B SL280UH090V36B 8810681EL16XC1-030-230A TXV 27,600 14.5 12.5 CX34-30B SLP98UH070XV36B 8810682EL16XC1-030-230A TXV 27,600 15.1 12.5 CX34-30C SLP98UH090XV36C 8810683EL16XC1-030-230A TXV 29,000 15.5 12.5 CX34-31A EL180UH045E36A 8810684EL16XC1-030-230A TXV 29,000 15.5 12.5 CX34-31A EL180UH045XE36A 8810685EL16XC1-030-230A TXV 29,000 16 13 CX34-31A SL280UH070V36A 8810686EL16XC1-030-230A TXV 29,000 16 13 CX34-31A SL280UH070XV36A 8810687EL16XC1-030-230A TXV 28,600 14.25 12.2 CX34-31A 8810688EL16XC1-030-230A TXV 29,200 16 13 CX34-31B EL180UH070E36B 8810689EL16XC1-030-230A TXV 29,200 16 13 CX34-31B EL180UH070XE36B 8810690EL16XC1-030-230A TXV 29,200 16 13 CX34-31B EL180UH090E48B 8810691EL16XC1-030-230A TXV 29,200 16 13 CX34-31B EL180UH090XE48B 8810692EL16XC1-030-230A TXV 29,000 15.5 12.5 CX34-31B EL195UH045XE36B 8810693EL16XC1-030-230A TXV 29,200 15.5 12.5 CX34-31B EL195UH070XE36B 8810694EL16XC1-030-230A TXV 29,000 15.5 12.5 CX34-31B EL296UH045XE36B 8810695EL16XC1-030-230A TXV 29,000 15.5 12.5 CX34-31B EL296UH045XV36B 8810696EL16XC1-030-230A TXV 29,200 15.5 12.5 CX34-31B EL296UH070XE36B 8810697EL16XC1-030-230A TXV 29,000 16 13 CX34-31B EL296UH070XV36B 8810698EL16XC1-030-230A TXV 29,000 16 13 CX34-31B SL280UH090V36B 8810699EL16XC1-030-230A TXV 29,000 16 13 CX34-31B SLP98UH070XV36B 8810700EL16XC1-030-230A TXV 28,600 14.25 12.2 CX34-31B 8810701EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-36A EL180UH045E36A 8810702EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-36A EL180UH045XE36A 8810703EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-36A SL280UH070V36A 8810704EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-36A SL280UH070XV36A 8810705EL16XC1-030-230A TXV 28,600 15.5 12.5 CX34-36B EL180UH070E36B 8810706EL16XC1-030-230A TXV 28,600 15.5 12.5 CX34-36B EL180UH070XE36B 8810707NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 37: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 37

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 28,600 15.5 13 CX34-36B EL180UH090E48B 8810708EL16XC1-030-230A TXV 28,600 15.5 13 CX34-36B EL180UH090XE48B 8810709EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-36B EL195UH045XE36B 8810710EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-36B EL195UH070XE36B 8810711EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-36B EL296UH045XE36B 8810712EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-36B EL296UH045XV36B 8810713EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-36B EL296UH070XE36B 8810714EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-36B EL296UH070XV36B 8810715EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-36B SL280UH090V36B 8810716EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-36B SLP98UH070XV36B 8810717EL16XC1-030-230A TXV 28,200 15.5 12.5 CX34-36C EL195UH090XE48C 8810718EL16XC1-030-230A TXV 28,200 15.5 12.5 CX34-36C EL296UH090XE48C 8810719EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-36C EL296UH090XV36C 8810720EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-36C SLP98UH090XV36C 8810721EL16XC1-030-230A TXV 29,200 16 13 CX34-38A EL180UH045E36A 8810722EL16XC1-030-230A TXV 29,200 16 13 CX34-38A EL180UH045XE36A 8810723EL16XC1-030-230A TXV 29,200 16 13 CX34-38A SL280UH070V36A 8810724EL16XC1-030-230A TXV 29,200 16 13 CX34-38A SL280UH070XV36A 8810725EL16XC1-030-230A TXV 28,800 14.5 12.2 CX34-38A 8810726EL16XC1-030-230A TXV 29,400 16 13 CX34-38B EL180UH070E36B 8810727EL16XC1-030-230A TXV 29,400 16 13 CX34-38B EL180UH070XE36B 8810728EL16XC1-030-230A TXV 29,400 16 13 CX34-38B EL180UH090E48B 8810729EL16XC1-030-230A TXV 29,400 16 13 CX34-38B EL180UH090XE48B 8810730EL16XC1-030-230A TXV 29,200 15.5 13 CX34-38B EL195UH045XE36B 8810731EL16XC1-030-230A TXV 29,400 15.5 13 CX34-38B EL195UH070XE36B 8810732EL16XC1-030-230A TXV 29,200 15.5 13 CX34-38B EL296UH045XE36B 8810733EL16XC1-030-230A TXV 29,400 15.5 13 CX34-38B EL296UH045XV36B 8810734EL16XC1-030-230A TXV 29,400 15.5 13 CX34-38B EL296UH070XE36B 9965379EL16XC1-030-230A TXV 29,400 16 13 CX34-38B EL296UH070XV36B 8810736EL16XC1-030-230A TXV 29,400 16 13 CX34-38B SL280UH090V36B 8810737EL16XC1-030-230A TXV 29,400 16 13 CX34-38B SLP98UH070XV36B 8810738EL16XC1-030-230A TXV 28,800 14.5 12.2 CX34-38B 8810739EL16XC1-030-230A TXV 28,600 15.5 12.5 CX34-42 EL180UH070E36B 8810740EL16XC1-030-230A TXV 28,600 15.5 12.5 CX34-42 EL180UH070XE36B 8810741EL16XC1-030-230A TXV 28,600 15.5 13 CX34-42 EL180UH090E48B 8810742EL16XC1-030-230A TXV 28,600 15.5 13 CX34-42 EL180UH090XE48B 8810743EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-42 EL195UH045XE36B 8810744EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-42 EL195UH070XE36B 8810745EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-42 EL296UH045XE36B 8810746EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-42 EL296UH045XV36B 8810747EL16XC1-030-230A TXV 28,400 15.1 12.5 CX34-42 EL296UH070XE36B 8810748EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-42 EL296UH070XV36B 8810749EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-42 SL280UH090V36B 8810750EL16XC1-030-230A TXV 28,400 15.5 12.5 CX34-42 SLP98UH070XV36B 8810751EL16XC1-030-230A TXV 29,600 16 13 CX34-43B EL180UH070E36B 8810752EL16XC1-030-230A TXV 29,600 16 13 CX34-43B EL180UH070XE36B 8810753EL16XC1-030-230A TXV 29,600 16 13 CX34-43B EL180UH090E48B 8810754EL16XC1-030-230A TXV 29,600 16 13 CX34-43B EL180UH090XE48B 8810755EL16XC1-030-230A TXV 29,400 16 13 CX34-43B EL195UH045XE36B 8810756NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 38: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 38

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 29,600 16 13 CX34-43B EL195UH070XE36B 8810757EL16XC1-030-230A TXV 29,400 16 13 CX34-43B EL296UH045XE36B 8810758EL16XC1-030-230A TXV 29,400 15.5 13 CX34-43B EL296UH045XV36B 8810759EL16XC1-030-230A TXV 29,600 16 13 CX34-43B EL296UH070XE36B 8810760EL16XC1-030-230A TXV 29,400 16 13 CX34-43B EL296UH070XV36B 8810761EL16XC1-030-230A TXV 29,400 16 13 CX34-43B SL280UH090V36B 8810762EL16XC1-030-230A TXV 29,400 16 13 CX34-43B SLP98UH070XV36B 8810763EL16XC1-030-230A TXV 28,800 14.5 12.2 CX34-43B 8810764EL16XC1-030-230A TXV 29,400 16 13 CX34-43C EL195UH090XE48C 8810765EL16XC1-030-230A TXV 29,400 16 13 CX34-43C EL296UH090XE48C 8810766EL16XC1-030-230A TXV 29,400 16 13 CX34-43C EL296UH090XV36C 8810767EL16XC1-030-230A TXV 29,200 16 13 CX34-43C EL296UH090XV48C 8810768EL16XC1-030-230A TXV 29,400 16 13 CX34-43C SLP98UH090XV36C 8810769EL16XC1-030-230A TXV 29,200 16 13 CX34-43C SLP98UH090XV48C 8810770EL16XC1-030-230A TXV 28,800 14.5 12.2 CX34-43C 8810771EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-24A EL180UH045E36A 8810772EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-24A EL180UH045XE36A 8810773EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-24A SL280UH070V36A 8810774EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-24A SL280UH070XV36A 8810775EL16XC1-030-230A TXV 28,600 15.5 13 CX35-24B EL180UH070E36B 8810776EL16XC1-030-230A TXV 28,600 15.5 13 CX35-24B EL180UH070XE36B 8810777EL16XC1-030-230A TXV 28,600 15.5 13 CX35-24B EL180UH090E48B 8810778EL16XC1-030-230A TXV 28,600 15.5 13 CX35-24B EL180UH090XE48B 8810779EL16XC1-030-230A TXV 28,600 15.1 12.5 CX35-24B EL195UH045XE36B 8810780EL16XC1-030-230A TXV 28,800 15.1 12.5 CX35-24B EL195UH070XE36B 8810781EL16XC1-030-230A TXV 28,600 15.1 12.5 CX35-24B EL296UH045XE36B 8810782EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-24B EL296UH045XV36B 8810783EL16XC1-030-230A TXV 28,800 15.1 12.5 CX35-24B EL296UH070XE36B 8810784EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-24B EL296UH070XV36B 8810785EL16XC1-030-230A TXV 28,600 16 13 CX35-24B SL280UH090V36B 8810786EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-24B SLP98UH070XV36B 8810787EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-30/36A EL180UH045E36A 8810788EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-30/36A EL180UH045XE36A 8810789EL16XC1-030-230A TXV 28,400 15.5 12.5 CX35-30/36A SL280UH070V36A 8810790EL16XC1-030-230A TXV 28,400 15.5 12.5 CX35-30/36A SL280UH070XV36A 8810791EL16XC1-030-230A TXV 28,600 15.5 13 CX35-30/36B EL180UH070E36B 8810792EL16XC1-030-230A TXV 28,600 15.5 13 CX35-30/36B EL180UH070XE36B 8810793EL16XC1-030-230A TXV 28,600 16 13 CX35-30/36B EL180UH090E48B 8810794EL16XC1-030-230A TXV 28,600 16 13 CX35-30/36B EL180UH090XE48B 8810795EL16XC1-030-230A TXV 28,600 15.1 12.5 CX35-30/36B EL195UH045XE36B 8810796EL16XC1-030-230A TXV 28,600 15.1 12.5 CX35-30/36B EL195UH070XE36B 8810797EL16XC1-030-230A TXV 28,600 15.1 12.5 CX35-30/36B EL296UH045XE36B 8810798EL16XC1-030-230A TXV 28,600 15.1 12.5 CX35-30/36B EL296UH045XV36B 8810799EL16XC1-030-230A TXV 28,600 15.1 12.5 CX35-30/36B EL296UH070XE36B 8810800EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-30/36B EL296UH070XV36B 8810801EL16XC1-030-230A TXV 28,600 15.5 13 CX35-30/36B SL280UH090V36B 8810802EL16XC1-030-230A TXV 28,600 15.5 12.5 CX35-30/36B SLP98UH070XV36B 8810803EL16XC1-030-230A TXV 28,400 15.5 12.5 CX35-30/36C EL195UH090XE48C 8810804EL16XC1-030-230A TXV 28,400 15.5 12.5 CX35-30/36C EL296UH090XE48C 8810805NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 39: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 39

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 28,400 15.5 13 CX35-30/36C EL296UH090XV36C 8810806EL16XC1-030-230A TXV 28,400 15.5 13 CX35-30/36C SLP98UH090XV36C 8810807EL16XC1-030-230A TXV 29,200 15.5 13 CX35-30A EL180UH045E36A 8810808EL16XC1-030-230A TXV 29,200 15.5 13 CX35-30A EL180UH045XE36A 8810809EL16XC1-030-230A TXV 29,200 16 13 CX35-30A SL280UH070V36A 8810810EL16XC1-030-230A TXV 29,200 16 13 CX35-30A SL280UH070XV36A 8810811EL16XC1-030-230A TXV 28,600 14.25 12.2 CX35-30A 8810812EL16XC1-030-230A TXV 29,200 16 13 CX35-30B EL180UH070E36B 8810813EL16XC1-030-230A TXV 29,200 16 13 CX35-30B EL180UH070XE36B 8810814EL16XC1-030-230A TXV 29,200 16 13 CX35-30B EL180UH090E48B 8810815EL16XC1-030-230A TXV 29,200 16 13 CX35-30B EL180UH090XE48B 8810816EL16XC1-030-230A TXV 29,200 15.5 12.5 CX35-30B EL195UH045XE36B 8810817EL16XC1-030-230A TXV 29,400 15.5 12.5 CX35-30B EL195UH070XE36B 8810818EL16XC1-030-230A TXV 29,200 15.5 12.5 CX35-30B EL296UH045XE36B 8810819EL16XC1-030-230A TXV 29,200 15.5 12.5 CX35-30B EL296UH045XV36B 8810820EL16XC1-030-230A TXV 29,400 15.5 12.5 CX35-30B EL296UH070XE36B 8810821EL16XC1-030-230A TXV 29,200 16 13 CX35-30B EL296UH070XV36B 8810822EL16XC1-030-230A TXV 29,200 16 13 CX35-30B SL280UH090V36B 8810823EL16XC1-030-230A TXV 29,200 16 13 CX35-30B SLP98UH070XV36B 8810824EL16XC1-030-230A TXV 28,600 14.25 12.2 CX35-30B 8810825EL16XC1-030-230A TXV 29,400 16 13 CX35-36A EL180UH045E36A 8810826EL16XC1-030-230A TXV 29,400 16 13 CX35-36A EL180UH045XE36A 8810827EL16XC1-030-230A TXV 29,400 16 13 CX35-36A SL280UH070V36A 8810828EL16XC1-030-230A TXV 29,400 16 13 CX35-36A SL280UH070XV36A 8810829EL16XC1-030-230A TXV 28,800 14.5 12.2 CX35-36A 8810830EL16XC1-030-230A TXV 29,600 16 13 CX35-36B EL180UH070E36B 8810831EL16XC1-030-230A TXV 29,600 16 13 CX35-36B EL180UH070XE36B 8810832EL16XC1-030-230A TXV 29,600 16 13 CX35-36B EL180UH090E48B 8810833EL16XC1-030-230A TXV 29,600 16 13 CX35-36B EL180UH090XE48B 8810834EL16XC1-030-230A TXV 29,400 15.5 13 CX35-36B EL195UH045XE36B 8810835EL16XC1-030-230A TXV 29,600 16 13 CX35-36B EL195UH070XE36B 8810836EL16XC1-030-230A TXV 29,400 15.5 13 CX35-36B EL296UH045XE36B 8810837EL16XC1-030-230A TXV 29,400 15.5 13 CX35-36B EL296UH045XV36B 8810838EL16XC1-030-230A TXV 29,600 16 13 CX35-36B EL296UH070XE36B 8810839EL16XC1-030-230A TXV 29,400 16 13 CX35-36B EL296UH070XV36B 8810840EL16XC1-030-230A TXV 29,400 16 13 CX35-36B SL280UH090V36B 8810841EL16XC1-030-230A TXV 29,400 16 13 CX35-36B SLP98UH070XV36B 8810842EL16XC1-030-230A TXV 28,800 14.5 12.2 CX35-36B 8810843EL16XC1-030-230A TXV 29,600 16 13 CX35-48B EL180UH070E36B 8810844EL16XC1-030-230A TXV 29,600 16 13 CX35-48B EL180UH070XE36B 8810845EL16XC1-030-230A TXV 29,600 16 13 CX35-48B EL180UH090E48B 8810846EL16XC1-030-230A TXV 29,600 16 13 CX35-48B EL180UH090XE48B 8810847EL16XC1-030-230A TXV 29,400 16 13 CX35-48B EL195UH045XE36B 8810848EL16XC1-030-230A TXV 29,600 16 13 CX35-48B EL195UH070XE36B 8810849EL16XC1-030-230A TXV 29,400 16 13 CX35-48B EL296UH045XE36B 8810850EL16XC1-030-230A TXV 29,400 15.5 13 CX35-48B EL296UH045XV36B 8810851EL16XC1-030-230A TXV 29,600 16 13 CX35-48B EL296UH070XE36B 8810852EL16XC1-030-230A TXV 29,400 16 13 CX35-48B EL296UH070XV36B 8810853EL16XC1-030-230A TXV 29,400 16 13 CX35-48B SL280UH090V36B 8810854NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 40: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 40

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-030-230A TXV 29,400 16 13 CX35-48B SLP98UH070XV36B 8810855EL16XC1-030-230A TXV 29,000 14.5 12.2 CX35-48B 8810856EL16XC1-030-230A TXV 29,400 16 13 CX35-48C EL195UH090XE48C 8810857EL16XC1-030-230A TXV 29,400 16 13 CX35-48C EL296UH090XE48C 8810858EL16XC1-030-230A TXV 29,400 16 13 CX35-48C EL296UH090XV36C 8810859EL16XC1-030-230A TXV 29,200 16 13 CX35-48C EL296UH090XV48C 8810860EL16XC1-030-230A TXV 29,400 16 13 CX35-48C SLP98UH090XV36C 8810861EL16XC1-030-230A TXV 29,200 16 13 CX35-48C SLP98UH090XV48C 8810862EL16XC1-030-230A TXV 29,000 14.5 12.2 CX35-48C 8810863EL16XC1-041-230A TXV 37,800 16.85 13 C33-38 EL180UH090E48B 8898147EL16XC1-041-230A TXV 37,800 16.85 13 C33-38 EL180UH090XE48B 8898148EL16XC1-041-230A TXV 38,000 17.05 13 C33-43 EL180UH090E48B 8898201EL16XC1-041-230A TXV 38,500 17.45 13.5 C33-43 EL180UH090E60C 8898203EL16XC1-041-230A TXV 38,000 17.05 13 C33-43 EL180UH090XE48B 8898202EL16XC1-041-230A TXV 38,000 17.4 13 C33-43 EL180UH110E60C 8898204EL16XC1-041-230A TXV 38,000 17.4 13 C33-43 EL180UH110XE60C 8898205EL16XC1-041-230A TXV 38,000 17.1 13 C33-43 EL195UH090XE48C 8898206EL16XC1-041-230A TXV 37,600 17.5 13.5 C33-43 EL195UH110XE60C 8898207EL16XC1-041-230A TXV 38,000 17.1 13 C33-43 EL296UH090XE48C 8898208EL16XC1-041-230A TXV 37,600 17.5 13.5 C33-43 EL296UH110XE60C 8898209EL16XC1-041-230A TXV 38,500 17.4 13.5 C33-43 SL280UH090V60C 8898210EL16XC1-041-230A TXV 38,500 17.4 13.5 C33-43 SL280UH090XV60C 8898211EL16XC1-041-230A TXV 38,000 17.05 13 C33-43 SL280UH110V60C 8898212EL16XC1-041-230A TXV 38,000 17.05 13 C33-43 SL280UH110XV60C 8898213EL16XC1-041-230A TXV 37,600 15.65 12.5 C33-43 8898200EL16XC1-041-230A TXV 37,400 16.7 13 C33-48 EL180UH090E48B 8898149EL16XC1-041-230A TXV 37,400 17.05 13 C33-48 EL180UH090E60C 8898214EL16XC1-041-230A TXV 37,400 16.7 13 C33-48 EL180UH090XE48B 8898150EL16XC1-041-230A TXV 37,400 17 13 C33-48 EL180UH110E60C 8898151EL16XC1-041-230A TXV 37,400 17 13 C33-48 EL180UH110XE60C 8898152EL16XC1-041-230A TXV 37,200 16.8 13 C33-48 EL195UH090XE48C 8898215EL16XC1-041-230A TXV 36,800 17.15 13 C33-48 EL195UH110XE60C 8898216EL16XC1-041-230A TXV 37,200 16.8 13 C33-48 EL296UH090XE48C 8898217EL16XC1-041-230A TXV 36,800 17.15 13 C33-48 EL296UH110XE60C 8898218EL16XC1-041-230A TXV 39,000 17.6 13.5 C33-49 EL180UH090E60C 8898220EL16XC1-041-230A TXV 38,500 17.55 13.5 C33-49 EL180UH110E60C 8898221EL16XC1-041-230A TXV 38,500 17.55 13.5 C33-49 EL180UH110XE60C 8898222EL16XC1-041-230A TXV 38,500 17.3 13.5 C33-49 EL195UH090XE48C 8898223EL16XC1-041-230A TXV 38,000 17.6 13.5 C33-49 EL195UH110XE60C 8898224EL16XC1-041-230A TXV 38,500 17.3 13.5 C33-49 EL296UH090XE48C 8898225EL16XC1-041-230A TXV 38,000 17.6 13.5 C33-49 EL296UH110XE60C 8898226EL16XC1-041-230A TXV 38,000 15.8 12.5 C33-49 8898219EL16XC1-041-230A TXV 37,800 17.15 13 C33-50/60C EL180UH090E60C 8898227EL16XC1-041-230A TXV 37,800 17.15 13 C33-50/60C EL180UH110E60C 8898228EL16XC1-041-230A TXV 37,800 17.15 13 C33-50/60C EL180UH110XE60C 8898229EL16XC1-041-230A TXV 37,600 16.95 13 C33-50/60C EL195UH090XE48C 8898153EL16XC1-041-230A TXV 37,200 17.3 13 C33-50/60C EL195UH110XE60C 8898230EL16XC1-041-230A TXV 37,600 16.95 13 C33-50/60C EL296UH090XE48C 8898154EL16XC1-041-230A TXV 37,200 17.3 13 C33-50/60C EL296UH110XE60C 8898231NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 41: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 41

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-041-230A TXV 39,000 17.8 13.5 C33-62C EL180UH090E60C 8898232EL16XC1-041-230A TXV 39,000 17.75 13.5 C33-62C EL180UH110E60C 8898233EL16XC1-041-230A TXV 39,000 17.75 13.5 C33-62C EL180UH110XE60C 8898234EL16XC1-041-230A TXV 39,000 17.55 13.5 C33-62C EL195UH090XE48C 8898235EL16XC1-041-230A TXV 39,500 17.45 13.5 C33-62C EL195UH110XE60C 8898236EL16XC1-041-230A TXV 39,000 17.55 13.5 C33-62C EL296UH090XE48C 8898237EL16XC1-041-230A TXV 39,500 17.45 13.5 C33-62C EL296UH110XE60C 8898238EL16XC1-041-230A TXV 39,000 17.5 13.5 C33-62C SLP98UH090XV48C 8898239EL16XC1-041-230A TXV 38,000 16.9 13 C35-36B EL180UH090E48B 8898155EL16XC1-041-230A TXV 38,000 16.9 13 C35-36B EL180UH090XE48B 8898156EL16XC1-041-230A TXV 37,400 15.6 12.5 C35-36B 8898240EL16XC1-041-230A TXV 38,500 17.05 13 C35-48B EL180UH090E48B 8898241EL16XC1-041-230A TXV 38,500 17.05 13 C35-48B EL180UH090XE48B 8898242EL16XC1-041-230A TXV 37,800 15.65 12.5 C35-48B 8898243EL16XC1-041-230A TXV 38,500 17.5 13.5 C35-48C EL180UH090E60C 8898244EL16XC1-041-230A TXV 38,500 17.45 13.5 C35-48C EL180UH110E60C 8898245EL16XC1-041-230A TXV 38,500 17.45 13.5 C35-48C EL180UH110XE60C 8898246EL16XC1-041-230A TXV 38,000 17.15 13 C35-48C EL195UH090XE48C 8898247EL16XC1-041-230A TXV 37,800 17.55 13.5 C35-48C EL195UH110XE60C 8898248EL16XC1-041-230A TXV 38,000 17.15 13 C35-48C EL296UH090XE48C 8898249EL16XC1-041-230A TXV 37,800 17.55 13.5 C35-48C EL296UH110XE60C 8898250EL16XC1-041-230A TXV 38,500 17.25 13.5 C35-48C EL296UH110XV48C 8898251EL16XC1-041-230A TXV 38,500 17.5 13.5 C35-48C SL280UH090V60C 8898252EL16XC1-041-230A TXV 38,500 17.5 13.5 C35-48C SL280UH090XV60C 8898253EL16XC1-041-230A TXV 38,000 17.05 13 C35-48C SL280UH110V60C 8898254EL16XC1-041-230A TXV 38,000 17.05 13 C35-48C SL280UH110XV60C 8898255EL16XC1-041-230A TXV 37,800 15.65 12.5 C35-48C 8898256EL16XC1-041-230A TXV 39,000 17.6 13.5 C35-49C EL180UH090E60C 8898257EL16XC1-041-230A TXV 38,500 17.6 13.5 C35-49C EL180UH110E60C 8898258EL16XC1-041-230A TXV 38,500 17.6 13.5 C35-49C EL180UH110XE60C 8898259EL16XC1-041-230A TXV 38,500 17.35 13.5 C35-49C EL195UH090XE48C 8898260EL16XC1-041-230A TXV 39,000 17.25 13 C35-49C EL195UH110XE60C 8898261EL16XC1-041-230A TXV 38,500 17.35 13.5 C35-49C EL296UH090XE48C 8898262EL16XC1-041-230A TXV 39,000 17.25 13 C35-49C EL296UH110XE60C 8898263EL16XC1-041-230A TXV 38,500 17.35 13 C35-49C EL296UH110XV48C 8898264EL16XC1-041-230A TXV 39,000 17.6 13.5 C35-49C SL280UH090XV60C 8898265EL16XC1-041-230A TXV 39,000 17.55 13.5 C35-49C SL280UH110XV60C 8898266EL16XC1-041-230A TXV 38,000 15.8 12.5 C35-49C 8898267EL16XC1-041-230A TXV 38,000 17.2 13 C35-50/60C EL180UH090E60C 8898268EL16XC1-041-230A TXV 37,800 17.2 13 C35-50/60C EL180UH110E60C 8898269EL16XC1-041-230A TXV 37,800 17.2 13 C35-50/60C EL180UH110XE60C 8898270EL16XC1-041-230A TXV 37,600 16.95 13 C35-50/60C EL195UH090XE48C 8898157EL16XC1-041-230A TXV 37,400 17.3 13 C35-50/60C EL195UH110XE60C 8898271EL16XC1-041-230A TXV 37,600 16.95 13 C35-50/60C EL296UH090XE48C 8898158EL16XC1-041-230A TXV 37,400 17.3 13 C35-50/60C EL296UH110XE60C 8898272EL16XC1-041-230A TXV 38,000 16.95 13 C35-50/60C EL296UH110XV48C 8898159EL16XC1-041-230A TXV 37,600 15.1 12.5 C35-50/60C 8898273EL16XC1-041-230A TXV 39,500 17.85 13.5 C35-60C EL180UH090E60C 8898274EL16XC1-041-230A TXV 39,000 17.8 13.5 C35-60C EL180UH110E60C 8898275NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 42: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 42

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-041-230A TXV 39,000 17.8 13.5 C35-60C EL180UH110XE60C 8898276EL16XC1-041-230A TXV 39,000 17.6 13.5 C35-60C EL195UH090XE48C 8898277EL16XC1-041-230A TXV 39,500 17.5 13.5 C35-60C EL195UH110XE60C 8898278EL16XC1-041-230A TXV 39,000 17.6 13.5 C35-60C EL296UH090XE48C 8898279EL16XC1-041-230A TXV 39,500 17.5 13.5 C35-60C EL296UH110XE60C 8898280EL16XC1-041-230A TXV 39,000 17.55 13.5 C35-60C SLP98UH090XV48C 8898281EL16XC1-041-230A TXV 38,500 16.05 13 C35-60C 8898282EL16XC1-041-230A TXV 38,500 17 13.5 CBA27UHE-048 10259411EL16XC1-041-230A TXV 37,200 16 13 CBX25UH-042 8898283EL16XC1-041-230A TXV 38,000 16.25 13 CBX25UH-048 8898284EL16XC1-041-230A TXV 38,000 17.6 13.5 CBX25UHV-042 8898285EL16XC1-041-230A TXV 38,500 17.6 13.5 CBX25UHV-048 8898286EL16XC1-041-230A TXV 38,500 17.3 13.5 CBX27UH-048 8898287EL16XC1-041-230A TXV 38,000 17.15 13 CBX32MV-048 8898288EL16XC1-041-230A TXV 38,000 17.1 13 CBX40UHV-048 8898289EL16XC1-041-230A TXV 36,400 17.2 13 CH23-51 EL180UH090E60C 8898290EL16XC1-041-230A TXV 36,600 17.05 13 CH23-51 SL280UH090V60C 8898291EL16XC1-041-230A TXV 37,000 17.4 13.5 CH23-65 EL180UH090E60C 8898292EL16XC1-041-230A TXV 37,000 17.25 13 CH23-65 SL280UH090V60C 8898293EL16XC1-041-230A TXV 38,000 16.95 13 CH33-43B EL180UH090E48B 8898294EL16XC1-041-230A TXV 38,000 16.95 13 CH33-43B EL180UH090XE48B 8898295EL16XC1-041-230A TXV 38,000 16.75 13 CH33-43B SL280UH090V36B 8898160EL16XC1-041-230A TXV 38,000 16.8 13 CH33-43B SL280UH090V48B 8898161EL16XC1-041-230A TXV 38,000 16.8 13 CH33-43B SL280UH090XV48B 8898162EL16XC1-041-230A TXV 38,000 17.35 13 CH33-43C EL180UH090E60C 8898296EL16XC1-041-230A TXV 38,000 17.35 13 CH33-43C EL180UH110E60C 8898297EL16XC1-041-230A TXV 38,000 17.35 13 CH33-43C EL180UH110XE60C 8898298EL16XC1-041-230A TXV 38,000 17.1 13 CH33-43C EL195UH090XE48C 8898299EL16XC1-041-230A TXV 37,600 17.45 13.5 CH33-43C EL195UH110XE60C 8898300EL16XC1-041-230A TXV 38,000 17.1 13 CH33-43C EL296UH090XE48C 8898301EL16XC1-041-230A TXV 38,000 17 13 CH33-43C EL296UH090XV36C 8898302EL16XC1-041-230A TXV 38,000 17.1 13 CH33-43C EL296UH090XV48C 8898303EL16XC1-041-230A TXV 38,000 17.3 13 CH33-43C EL296UH090XV60C 8898304EL16XC1-041-230A TXV 37,600 17.45 13.5 CH33-43C EL296UH110XE60C 8898305EL16XC1-041-230A TXV 38,500 17.25 13.5 CH33-43C EL296UH110XV60C 8898306EL16XC1-041-230A TXV 38,500 17.45 13.5 CH33-43C SL280UH090V60C 8898307EL16XC1-041-230A TXV 38,500 17.45 13.5 CH33-43C SL280UH090XV60C 8898308EL16XC1-041-230A TXV 38,000 17.05 13 CH33-43C SL280UH110V60C 8898309EL16XC1-041-230A TXV 38,000 17.05 13 CH33-43C SL280UH110XV60C 8898310EL16XC1-041-230A TXV 38,000 17 13 CH33-43C SLP98UH090XV36C 8898311EL16XC1-041-230A TXV 38,000 17.1 13 CH33-43C SLP98UH090XV48C 8898312EL16XC1-041-230A TXV 38,000 17.3 13 CH33-43C SLP98UH090XV60C 8898313EL16XC1-041-230A TXV 38,500 17.25 13.5 CH33-43C SLP98UH110XV60C 8898314EL16XC1-041-230A TXV 37,800 16.85 13 CH33-44/48 EL180UH090E48B 8898163EL16XC1-041-230A TXV 37,800 16.85 13 CH33-44/48 EL180UH090XE48B 8898164EL16XC1-041-230A TXV 38,000 17.15 13 CH33-48C EL180UH090E60C 8898315EL16XC1-041-230A TXV 37,800 17.15 13 CH33-48C EL180UH110E60C 8898316EL16XC1-041-230A TXV 37,800 17.15 13 CH33-48C EL180UH110XE60C 8898317EL16XC1-041-230A TXV 37,600 16.95 13 CH33-48C EL195UH090XE48C 8898165NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 43: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 43

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-041-230A TXV 37,400 17.3 13 CH33-48C EL195UH110XE60C 8898318EL16XC1-041-230A TXV 37,600 16.95 13 CH33-48C EL296UH090XE48C 8898166EL16XC1-041-230A TXV 37,600 16.65 13 CH33-48C EL296UH090XV36C 8898319EL16XC1-041-230A TXV 37,800 16.85 13 CH33-48C EL296UH090XV48C 8898320EL16XC1-041-230A TXV 37,400 17.3 13 CH33-48C EL296UH110XE60C 8898321EL16XC1-041-230A TXV 37,600 16.65 13 CH33-48C SLP98UH090XV36C 8898322EL16XC1-041-230A TXV 37,800 16.85 13 CH33-48C SLP98UH090XV48C 8898323EL16XC1-041-230A TXV 38,500 17.5 13.5 CH33-49 EL180UH090E60C 8898324EL16XC1-041-230A TXV 38,500 17.5 13.5 CH33-49 EL180UH110E60C 8898325EL16XC1-041-230A TXV 38,500 17.5 13.5 CH33-49 EL180UH110XE60C 8898326EL16XC1-041-230A TXV 38,500 17.3 13 CH33-49 EL195UH090XE48C 8898327EL16XC1-041-230A TXV 39,000 17.15 13 CH33-49 EL195UH110XE60C 8898328EL16XC1-041-230A TXV 38,500 17.3 13 CH33-49 EL296UH090XE48C 8898329EL16XC1-041-230A TXV 39,000 17.15 13 CH33-49 EL296UH110XE60C 8898330EL16XC1-041-230A TXV 38,500 17.4 13.5 CH33-50/60C EL180UH090E60C 8898331EL16XC1-041-230A TXV 38,500 17.35 13.5 CH33-50/60C EL180UH110E60C 8898332EL16XC1-041-230A TXV 38,500 17.35 13.5 CH33-50/60C EL180UH110XE60C 8898333EL16XC1-041-230A TXV 38,000 17.15 13 CH33-50/60C EL195UH090XE48C 8898334EL16XC1-041-230A TXV 38,500 17.05 13 CH33-50/60C EL195UH110XE60C 8898335EL16XC1-041-230A TXV 38,000 17.15 13 CH33-50/60C EL296UH090XE48C 8898336EL16XC1-041-230A TXV 38,500 17.05 13 CH33-50/60C EL296UH110XE60C 8898337EL16XC1-041-230A TXV 38,000 15.75 12.5 CH33-50/60C 8898338EL16XC1-041-230A TXV 39,000 17.25 13.5 CH35-42B EL180UH090E48B 8898339EL16XC1-041-230A TXV 38,500 16.45 13 CH35-42B EL296UH045XV36B 9973363EL16XC1-041-230A TXV 39,000 17.05 13 CH35-42B SL280UH090V36B 8898340EL16XC1-041-230A TXV 39,000 17.1 13 CH35-42B SL280UH090V48B 8898341EL16XC1-041-230A TXV 38,500 16.4 13 CH35-42B SLP98UH070XV36B 8898342EL16XC1-041-230A TXV 38,500 15.95 12.5 CH35-42B 8898343EL16XC1-041-230A TXV 38,500 17.4 13.5 CH35-42C EL180UH090E60C 8898344EL16XC1-041-230A TXV 38,500 17.4 13.5 CH35-42C EL180UH110E60C 8898345EL16XC1-041-230A TXV 38,000 17.15 13 CH35-42C EL195UH090XE48C 8898346EL16XC1-041-230A TXV 37,800 17.5 13.5 CH35-42C EL195UH110XE60C 8898347EL16XC1-041-230A TXV 38,000 17.15 13 CH35-42C EL296UH090XE48C 8898348EL16XC1-041-230A TXV 38,000 17.05 13 CH35-42C EL296UH090XV36C 8898349EL16XC1-041-230A TXV 38,000 17.15 13 CH35-42C EL296UH090XV48C 8898350EL16XC1-041-230A TXV 38,000 17.35 13 CH35-42C EL296UH090XV60C 8898351EL16XC1-041-230A TXV 37,800 17.5 13.5 CH35-42C EL296UH110XE60C 8898352EL16XC1-041-230A TXV 38,500 17.25 13 CH35-42C EL296UH110XV48C 8898353EL16XC1-041-230A TXV 38,500 17.3 13.5 CH35-42C EL296UH110XV60C 8898354EL16XC1-041-230A TXV 38,500 17.5 13.5 CH35-42C SL280UH090V60C 8898355EL16XC1-041-230A TXV 38,500 17.1 13 CH35-42C SL280UH110V60C 8898356EL16XC1-041-230A TXV 38,000 17.05 13 CH35-42C SLP98UH090XV36C 8898357EL16XC1-041-230A TXV 38,000 17.15 13 CH35-42C SLP98UH090XV48C 8898358EL16XC1-041-230A TXV 38,000 17.35 13 CH35-42C SLP98UH090XV60C 8898359EL16XC1-041-230A TXV 38,500 17.3 13.5 CH35-42C SLP98UH110XV60C 8898360EL16XC1-041-230A TXV 37,800 15.7 12.5 CH35-42C 8898361EL16XC1-041-230A TXV 38,000 16.95 13 CH35-48B EL180UH090E48B 8898168EL16XC1-041-230A TXV 37,800 16.15 13 CH35-48B EL296UH045XV36B 9973360EL16XC1-041-230A TXV 37,600 15.65 12.5 CH35-48B 8898362NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 44: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 44

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-041-230A TXV 38,000 17.25 13 CH35-48C EL180UH090E60C 8898363EL16XC1-041-230A TXV 38,000 17.25 13 CH35-48C EL180UH110E60C 8898364EL16XC1-041-230A TXV 37,800 17 13 CH35-48C EL195UH090XE48C 8898170EL16XC1-041-230A TXV 38,000 16.9 13 CH35-48C EL195UH110XE60C 8898365EL16XC1-041-230A TXV 37,800 16.7 13 CH35-48C EL296UH090XV36C 8898171EL16XC1-041-230A TXV 38,000 16.9 13 CH35-48C EL296UH090XV48C 8898172EL16XC1-041-230A TXV 38,000 16.9 13 CH35-48C EL296UH110XE60C 8898366EL16XC1-041-230A TXV 38,000 16.95 13 CH35-48C EL296UH110XV48C 8898367EL16XC1-041-230A TXV 37,800 17.3 13 CH35-48C SL280UH090V60C 8898368EL16XC1-041-230A TXV 38,000 16.85 13 CH35-48C SL280UH110V60C 8898369EL16XC1-041-230A TXV 37,800 16.7 13 CH35-48C SLP98UH090XV36C 8898173EL16XC1-041-230A TXV 38,000 16.9 13 CH35-48C SLP98UH090XV48C 8898174EL16XC1-041-230A TXV 37,800 17.05 13 CH35-48C SLP98UH090XV60C 8898370EL16XC1-041-230A TXV 38,000 16.9 13 CH35-48C SLP98UH110XV60C 8898175EL16XC1-041-230A TXV 37,600 15.65 12.5 CH35-48C 8898371EL16XC1-041-230A TXV 39,000 17.55 13.5 CH35-51C EL180UH090E60C 8898372EL16XC1-041-230A TXV 38,500 17.55 13.5 CH35-51C EL180UH110E60C 8898373EL16XC1-041-230A TXV 38,500 17.35 13 CH35-51C EL195UH090XE48C 8898374EL16XC1-041-230A TXV 39,000 17.2 13 CH35-51C EL195UH110XE60C 8898375EL16XC1-041-230A TXV 38,500 17.35 13 CH35-51C EL296UH090XE48C 8898376EL16XC1-041-230A TXV 39,000 17.2 13 CH35-51C EL296UH110XE60C 8898377EL16XC1-041-230A TXV 39,000 17.2 13 CH35-51C EL296UH110XV48C 8898378EL16XC1-041-230A TXV 38,500 16.95 13 CH35-51C SLP98UH090XV36C 8898176EL16XC1-041-230A TXV 38,500 17.15 13 CH35-51C SLP98UH090XV48C 8898379EL16XC1-041-230A TXV 39,000 16.95 13 CH35-51C SLP98UH090XV60C 8898177EL16XC1-041-230A TXV 38,500 17.15 13 CH35-51C SLP98UH110XV60C 8898380EL16XC1-041-230A TXV 38,500 15.85 12.5 CH35-51C 8898178EL16XC1-041-230A TXV 37,600 16.95 13 CR33-50/60 EL195DF090XE48C 8898381EL16XC1-041-230A TXV 37,400 17.35 13 CR33-50/60 EL195DF110XE60C 8898382EL16XC1-041-230A TXV 37,600 16.95 13 CR33-50/60 EL296DF090XE48C 8898383EL16XC1-041-230A TXV 37,400 17.25 13 CR33-50/60 EL296DF090XV60C 8898384EL16XC1-041-230A TXV 37,400 17.35 13 CR33-50/60 EL296DF110XE60C 8898385EL16XC1-041-230A TXV 37,400 17.25 13 CR33-50/60 EL296DF110XV60C 8898386EL16XC1-041-230A TXV 37,800 17.25 13 CR33-50/60 SL280DF090V60C 8898387EL16XC1-041-230A TXV 38,000 17.35 13.5 CR33-50/60 SL280DF110V60C 8898388EL16XC1-041-230A TXV 37,800 16.85 13 CX34-38 EL180UH090E48B 8898179EL16XC1-041-230A TXV 37,800 16.85 13 CX34-38 EL180UH090XE48B 8898180EL16XC1-041-230A TXV 38,000 17.05 13 CX34-43 EL180UH090E48B 8898390EL16XC1-041-230A TXV 38,500 17.45 13.5 CX34-43 EL180UH090E60C 8898392EL16XC1-041-230A TXV 38,000 17.05 13 CX34-43 EL180UH090XE48B 8898391EL16XC1-041-230A TXV 38,000 17.4 13 CX34-43 EL180UH110E60C 8898393EL16XC1-041-230A TXV 38,000 17.4 13 CX34-43 EL180UH110XE60C 8898394EL16XC1-041-230A TXV 38,000 17.1 13 CX34-43 EL195UH090XE48C 8898395EL16XC1-041-230A TXV 37,600 17.5 13.5 CX34-43 EL195UH110XE60C 8898396EL16XC1-041-230A TXV 38,000 17.1 13 CX34-43 EL296UH090XE48C 8898397EL16XC1-041-230A TXV 38,000 16.9 13 CX34-43 EL296UH090XV36C 8898181EL16XC1-041-230A TXV 38,000 17.05 13 CX34-43 EL296UH090XV48C 8898398EL16XC1-041-230A TXV 37,800 17.2 13 CX34-43 EL296UH090XV60C 8898399EL16XC1-041-230A TXV 37,600 17.5 13.5 CX34-43 EL296UH110XE60C 8898400NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 45: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 45

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-041-230A TXV 38,000 17.2 13 CX34-43 EL296UH110XV60C 8898401EL16XC1-041-230A TXV 38,500 17.4 13.5 CX34-43 SL280UH090V60C 8898402EL16XC1-041-230A TXV 38,500 17.4 13.5 CX34-43 SL280UH090XV60C 8898403EL16XC1-041-230A TXV 38,000 17.05 13 CX34-43 SL280UH110V60C 8898404EL16XC1-041-230A TXV 38,000 17.05 13 CX34-43 SL280UH110XV60C 8898405EL16XC1-041-230A TXV 38,000 16.9 13 CX34-43 SLP98UH090XV36C 8898182EL16XC1-041-230A TXV 38,000 17.05 13 CX34-43 SLP98UH090XV48C 8898406EL16XC1-041-230A TXV 37,800 17.2 13 CX34-43 SLP98UH090XV60C 8898407EL16XC1-041-230A TXV 38,000 17.2 13 CX34-43 SLP98UH110XV60C 8898408EL16XC1-041-230A TXV 37,600 15.65 12.5 CX34-43 8898389EL16XC1-041-230A TXV 37,400 16.7 13 CX34-44/48 EL180UH090E48B 8898183EL16XC1-041-230A TXV 37,400 17.05 13 CX34-44/48 EL180UH090E60C 8898409EL16XC1-041-230A TXV 37,400 16.7 13 CX34-44/48 EL180UH090XE48B 8898184EL16XC1-041-230A TXV 37,400 17 13 CX34-44/48 EL180UH110E60C 8898185EL16XC1-041-230A TXV 37,400 17 13 CX34-44/48 EL180UH110XE60C 8898186EL16XC1-041-230A TXV 37,200 16.8 13 CX34-44/48 EL195UH090XE48C 8898410EL16XC1-041-230A TXV 36,800 17.15 13 CX34-44/48 EL195UH110XE60C 8898411EL16XC1-041-230A TXV 37,200 16.8 13 CX34-44/48 EL296UH090XE48C 8898412EL16XC1-041-230A TXV 36,800 17.15 13 CX34-44/48 EL296UH110XE60C 8898413EL16XC1-041-230A TXV 38,500 17.6 13.5 CX34-49 EL180UH090E60C 8898415EL16XC1-041-230A TXV 38,500 17.55 13.5 CX34-49 EL180UH110E60C 8898416EL16XC1-041-230A TXV 38,500 17.55 13.5 CX34-49 EL180UH110XE60C 8898417EL16XC1-041-230A TXV 38,000 17.3 13.5 CX34-49 EL195UH090XE48C 8898418EL16XC1-041-230A TXV 38,500 17.6 13.5 CX34-49 EL195UH110XE60C 8898419EL16XC1-041-230A TXV 38,500 17.3 13.5 CX34-49 EL296UH090XE48C 8898420EL16XC1-041-230A TXV 38,000 17.25 13 CX34-49 EL296UH090XV48C 8898421EL16XC1-041-230A TXV 38,500 17.6 13.5 CX34-49 EL296UH110XE60C 8898422EL16XC1-041-230A TXV 39,000 17.4 13 CX34-49 EL296UH110XV60C 8898423EL16XC1-041-230A TXV 38,500 17.6 13.5 CX34-49 SL280UH090V60C 8898424EL16XC1-041-230A TXV 38,500 17.2 13 CX34-49 SL280UH110V60C 8898425EL16XC1-041-230A TXV 38,000 17.4 13 CX34-49 SLP98UH110XV60C 8898426EL16XC1-041-230A TXV 39,000 15.8 12.5 CX34-49 8898414EL16XC1-041-230A TXV 37,800 17.15 13 CX34-50/60C EL180UH090E60C 8898427EL16XC1-041-230A TXV 37,800 17.15 13 CX34-50/60C EL180UH110E60C 8898428EL16XC1-041-230A TXV 37,800 17.15 13 CX34-50/60C EL180UH110XE60C 8898429EL16XC1-041-230A TXV 37,600 16.95 13 CX34-50/60C EL195UH090XE48C 8898187EL16XC1-041-230A TXV 37,200 17.3 13 CX34-50/60C EL195UH110XE60C 8898430EL16XC1-041-230A TXV 37,600 16.95 13 CX34-50/60C EL296UH090XE48C 8898188EL16XC1-041-230A TXV 37,200 17.3 13 CX34-50/60C EL296UH110XE60C 8898431EL16XC1-041-230A TXV 39,000 17.8 13.5 CX34-62C EL180UH090E60C 8898432EL16XC1-041-230A TXV 39,000 17.75 13.5 CX34-62C EL180UH110E60C 8898433EL16XC1-041-230A TXV 39,000 17.75 13.5 CX34-62C EL180UH110XE60C 8898434EL16XC1-041-230A TXV 39,000 17.55 13.5 CX34-62C EL195UH090XE48C 8898435EL16XC1-041-230A TXV 39,500 17.45 13.5 CX34-62C EL195UH110XE60C 8898436EL16XC1-041-230A TXV 39,000 17.55 13.5 CX34-62C EL296UH090XE48C 8898437EL16XC1-041-230A TXV 39,000 17.35 13.5 CX34-62C EL296UH090XV36C 8898438EL16XC1-041-230A TXV 39,000 17.5 13.5 CX34-62C EL296UH090XV48C 8898439EL16XC1-041-230A TXV 39,500 17.4 13.5 CX34-62C EL296UH090XV60C 8898440EL16XC1-041-230A TXV 39,500 17.45 13.5 CX34-62C EL296UH110XE60C 8898441NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 46: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 46

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-041-230A TXV 39,000 17.6 13.5 CX34-62C EL296UH110XV60C 8898442EL16XC1-041-230A TXV 39,500 17.85 13.5 CX34-62C SL280UH090V60C 8898443EL16XC1-041-230A TXV 39,000 17.45 13.5 CX34-62C SL280UH110V60C 8898444EL16XC1-041-230A TXV 39,000 17.35 13.5 CX34-62C SLP98UH090XV36C 8898445EL16XC1-041-230A TXV 39,000 17.5 13.5 CX34-62C SLP98UH090XV48C 8898446EL16XC1-041-230A TXV 39,500 17.4 13.5 CX34-62C SLP98UH090XV60C 8898447EL16XC1-041-230A TXV 39,000 17.6 13.5 CX34-62C SLP98UH110XV60C 8898448EL16XC1-041-230A TXV 38,000 16.9 13 CX35-36B EL180UH090E48B 8898189EL16XC1-041-230A TXV 38,000 16.9 13 CX35-36B EL180UH090XE48B 8898190EL16XC1-041-230A TXV 37,600 16.1 13 CX35-36B EL296UH045XV36B 8898191EL16XC1-041-230A TXV 37,800 16.7 13 CX35-36B SL280UH090V36B 8898449EL16XC1-041-230A TXV 38,000 16.75 13 CX35-36B SL280UH090V48B 8898192EL16XC1-041-230A TXV 37,600 16.05 13 CX35-36B SLP98UH070XV36B 8898450EL16XC1-041-230A TXV 37,400 15.6 12.5 CX35-36B 8898451EL16XC1-041-230A TXV 38,500 17.05 13 CX35-48B EL180UH090E48B 8898452EL16XC1-041-230A TXV 38,500 17.05 13 CX35-48B EL180UH090XE48B 8898453EL16XC1-041-230A TXV 37,800 16.45 13 CX35-48B EL296UH045XV36B 8898454EL16XC1-041-230A TXV 38,000 17 13 CX35-48B SL280UH090V36B 8898193EL16XC1-041-230A TXV 38,500 17.05 13 CX35-48B SL280UH090V48B 8898455EL16XC1-041-230A TXV 37,800 16.35 13 CX35-48B SLP98UH070XV36B 8898456EL16XC1-041-230A TXV 37,800 15.65 12.5 CX35-48B 8898457EL16XC1-041-230A TXV 38,500 17.5 13.5 CX35-48C EL180UH090E60C 8898458EL16XC1-041-230A TXV 38,500 17.45 13.5 CX35-48C EL180UH110E60C 8898459EL16XC1-041-230A TXV 38,500 17.45 13.5 CX35-48C EL180UH110XE60C 8898460EL16XC1-041-230A TXV 38,000 17.15 13 CX35-48C EL195UH090XE48C 8898461EL16XC1-041-230A TXV 37,800 17.55 13.5 CX35-48C EL195UH110XE60C 8898462EL16XC1-041-230A TXV 38,000 17.15 13 CX35-48C EL296UH090XE48C 8898463EL16XC1-041-230A TXV 38,000 16.95 13 CX35-48C EL296UH090XV36C 8898194EL16XC1-041-230A TXV 38,000 17.1 13 CX35-48C EL296UH090XV48C 8898464EL16XC1-041-230A TXV 38,000 17.25 13 CX35-48C EL296UH090XV60C 8898465EL16XC1-041-230A TXV 37,800 17.55 13.5 CX35-48C EL296UH110XE60C 8898466EL16XC1-041-230A TXV 38,500 17.05 13 CX35-48C EL296UH110XV48C 8898467EL16XC1-041-230A TXV 38,500 17.25 13.5 CX35-48C EL296UH110XV60C 8898468EL16XC1-041-230A TXV 38,500 17.5 13.5 CX35-48C SL280UH090V60C 8898469EL16XC1-041-230A TXV 38,500 17.5 13.5 CX35-48C SL280UH090XV60C 8898470EL16XC1-041-230A TXV 38,000 17.05 13 CX35-48C SL280UH110V60C 8898471EL16XC1-041-230A TXV 38,000 17.05 13 CX35-48C SL280UH110XV60C 8898472EL16XC1-041-230A TXV 38,000 16.95 13 CX35-48C SLP98UH090XV36C 8898195EL16XC1-041-230A TXV 38,000 17.1 13 CX35-48C SLP98UH090XV48C 8898473EL16XC1-041-230A TXV 38,000 17.25 13 CX35-48C SLP98UH090XV60C 8898474EL16XC1-041-230A TXV 38,500 17.25 13.5 CX35-48C SLP98UH110XV60C 8898475EL16XC1-041-230A TXV 37,800 15.65 12.5 CX35-48C 8898476EL16XC1-041-230A TXV 39,000 17.6 13.5 CX35-49C EL180UH090E60C 8898477EL16XC1-041-230A TXV 38,500 17.6 13.5 CX35-49C EL180UH110E60C 8898478EL16XC1-041-230A TXV 38,500 17.6 13.5 CX35-49C EL180UH110XE60C 8898479EL16XC1-041-230A TXV 38,500 17.35 13.5 CX35-49C EL195UH090XE48C 8898480EL16XC1-041-230A TXV 39,000 17.25 13 CX35-49C EL195UH110XE60C 8898481EL16XC1-041-230A TXV 38,500 17.35 13.5 CX35-49C EL296UH090XE48C 8898483EL16XC1-041-230A TXV 38,500 17.15 13 CX35-49C EL296UH090XV36C 8898482NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 47: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 47

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-041-230A TXV 38,500 17.3 13 CX35-49C EL296UH090XV48C 8898484EL16XC1-041-230A TXV 39,000 17.25 13 CX35-49C EL296UH110XE60C 8898486EL16XC1-041-230A TXV 38,500 17.35 13 CX35-49C EL296UH110XV48C 8898485EL16XC1-041-230A TXV 39,000 17.4 13.5 CX35-49C EL296UH110XV60C 8898487EL16XC1-041-230A TXV 39,000 17.6 13.5 CX35-49C SL280UH090V60C 8898488EL16XC1-041-230A TXV 38,500 17.25 13 CX35-49C SL280UH110V60C 8898489EL16XC1-041-230A TXV 38,500 17.15 13 CX35-49C SLP98UH090XV36C 8898490EL16XC1-041-230A TXV 38,500 17.3 13 CX35-49C SLP98UH090XV48C 8898491EL16XC1-041-230A TXV 39,000 17.15 13 CX35-49C SLP98UH090XV60C 8898492EL16XC1-041-230A TXV 39,000 17.4 13.5 CX35-49C SLP98UH110XV60C 8898493EL16XC1-041-230A TXV 38,000 15.8 12.5 CX35-49C 8898494EL16XC1-041-230A TXV 38,000 17.2 13 CX35-50/60C EL180UH090E60C 8898498EL16XC1-041-230A TXV 37,800 17.2 13 CX35-50/60C EL180UH110E60C 8898499EL16XC1-041-230A TXV 37,800 17.2 13 CX35-50/60C EL180UH110XE60C 8898500EL16XC1-041-230A TXV 37,600 16.95 13 CX35-50/60C EL195UH090XE48C 8898198EL16XC1-041-230A TXV 37,400 17.3 13 CX35-50/60C EL195UH110XE60C 8898501EL16XC1-041-230A TXV 37,600 16.95 13 CX35-50/60C EL296UH090XE48C 8898199EL16XC1-041-230A TXV 37,400 17.3 13 CX35-50/60C EL296UH110XE60C 8898502EL16XC1-041-230A TXV 38,000 16.8 13 CX35-50/60C EL296UH110XV48C 8898196EL16XC1-041-230A TXV 37,600 16.6 13 CX35-50/60C SLP98UH090XV36C 8898495EL16XC1-041-230A TXV 37,800 16.8 13 CX35-50/60C SLP98UH090XV48C 8898197EL16XC1-041-230A TXV 37,600 16.95 13 CX35-50/60C SLP98UH090XV60C 8898503EL16XC1-041-230A TXV 38,000 16.8 13 CX35-50/60C SLP98UH110XV60C 8898496EL16XC1-041-230A TXV 37,600 15.55 12.5 CX35-50/60C 8898497EL16XC1-041-230A TXV 39,500 17.85 13.5 CX35-60C EL180UH090E60C 8898505EL16XC1-041-230A TXV 39,000 17.8 13.5 CX35-60C EL180UH110E60C 8898506EL16XC1-041-230A TXV 39,000 17.8 13.5 CX35-60C EL180UH110XE60C 8898507EL16XC1-041-230A TXV 39,000 17.6 13.5 CX35-60C EL195UH090XE48C 8898508EL16XC1-041-230A TXV 39,500 17.5 13.5 CX35-60C EL195UH110XE60C 8898509EL16XC1-041-230A TXV 39,000 17.6 13.5 CX35-60C EL296UH090XE48C 8898510EL16XC1-041-230A TXV 39,000 17.4 13.5 CX35-60C EL296UH090XV36C 8898511EL16XC1-041-230A TXV 39,000 17.55 13.5 CX35-60C EL296UH090XV48C 8898512EL16XC1-041-230A TXV 39,500 17.4 13.5 CX35-60C EL296UH090XV60C 8898513EL16XC1-041-230A TXV 39,500 17.5 13.5 CX35-60C EL296UH110XE60C 8898514EL16XC1-041-230A TXV 39,500 17.7 13.5 CX35-60C EL296UH110XV60C 8898515EL16XC1-041-230A TXV 39,500 17.9 13.5 CX35-60C SL280UH090V60C 8898516EL16XC1-041-230A TXV 39,000 17.5 13.5 CX35-60C SL280UH110V60C 8898517EL16XC1-041-230A TXV 39,000 17.4 13.5 CX35-60C SLP98UH090XV36C 8898518EL16XC1-041-230A TXV 39,000 17.55 13.5 CX35-60C SLP98UH090XV48C 8898519EL16XC1-041-230A TXV 39,500 17.4 13.5 CX35-60C SLP98UH090XV60C 8898520EL16XC1-041-230A TXV 39,500 17.7 13.5 CX35-60C SLP98UH110XV60C 8898521EL16XC1-041-230A TXV 38,500 16.05 13 CX35-60C 8898504EL16XC1-042-230A RFC 40,500 14 12.2 C33-38B 8812888EL16XC1-042-230A RFC 40,500 14 12.2 C33-43B 8812903EL16XC1-042-230A RFC 40,500 14 12.2 C33-43C 8812925EL16XC1-042-230A RFC 41,000 14.25 12.2 C33-49 8812975EL16XC1-042-230A RFC 40,500 14 12.2 C33-50/60C 8812997EL16XC1-042-230A RFC 41,000 14.25 12.5 C33-60D 8813003EL16XC1-042-230A RFC 42,000 14.5 12.5 C33-62C 8813025NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 48: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 48

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A RFC 41,500 14.5 12.5 C33-62D 8813031EL16XC1-042-230A RFC 40,500 14 12.2 C35-36B 8813057EL16XC1-042-230A RFC 41,000 14.25 12.5 C35-48B 8813075EL16XC1-042-230A RFC 41,000 14.25 12.5 C35-49C 8813117EL16XC1-042-230A RFC 40,500 14 12.2 C35-50/60C 8813714EL16XC1-042-230A RFC 40,500 14 12.2 C35-60C 8813160EL16XC1-042-230A RFC 41,500 14.5 12.5 C35-60D 8813162EL16XC1-042-230A RFC 41,000 14.25 12.2 CH33-43C 8813240EL16XC1-042-230A RFC 41,500 14.5 12.5 CH33-49 8813289EL16XC1-042-230A RFC 41,500 14.5 12.5 CH33-50/60C 8813311EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-36B EL180UH090E48B 8812856EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-36B EL180UH090XE48B 8812857EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-36B SL280UH090V36B 8812858EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-36B SL280UH090V48B 8812859EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-36B SL280UH090XV48B 8812860EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-36C EL180UH090E60C 8812861EL16XC1-042-230A TXV 39,000 15.1 12.5 C33-36C EL180UH110E60C 8812862EL16XC1-042-230A TXV 39,000 15.1 12.5 C33-36C EL180UH110XE60C 8812863EL16XC1-042-230A TXV 39,000 15.1 12.5 C33-36C EL195UH090XE48C 8812864EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-36C EL195UH110XE60C 8812865EL16XC1-042-230A TXV 39,000 15.1 12.5 C33-36C EL296UH090XE48C 8812866EL16XC1-042-230A TXV 39,000 14.5 12.2 C33-36C EL296UH090XV36C 8812867EL16XC1-042-230A TXV 39,000 15.1 12.5 C33-36C EL296UH090XV48C 8812868EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-36C EL296UH090XV60C 8812869EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-36C EL296UH110XE60C 8812870EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-36C EL296UH110XV60C 8812871EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-36C SL280UH090V60C 8812872EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-36C SL280UH090XV60C 8812873EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-36C SL280UH110V60C 8812874EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-36C SL280UH110XV60C 8812875EL16XC1-042-230A TXV 39,000 14.5 12.2 C33-36C SLP98UH090XV36C 8812876EL16XC1-042-230A TXV 39,000 15.1 12.5 C33-36C SLP98UH090XV48C 8812877EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-36C SLP98UH090XV60C 8812878EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-36C SLP98UH110XV60C 8812879EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-38B EL180UH090E48B 8812880EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-38B EL180UH090XE48B 8812881EL16XC1-042-230A TXV 40,500 15.1 12.5 C33-38B EL296UH045XV36B 8812882EL16XC1-042-230A TXV 40,500 14.5 12.5 C33-38B EL296UH070XV36B 8812883EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-38B SL280UH090V36B 8812884EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-38B SL280UH090V48B 8812885EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-38B SL280UH090XV48B 8812886EL16XC1-042-230A TXV 40,500 14.5 12.5 C33-38B SLP98UH070XV36B 8812887EL16XC1-042-230A TXV 40,500 14.5 12.2 C33-38B 8812889EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-42 EL180UH090E48B 8812890EL16XC1-042-230A TXV 39,500 15.1 12.5 C33-42 EL180UH090XE48B 8812891EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-42 SL280UH090V36B 8812892EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-42 SL280UH090V48B 8812893EL16XC1-042-230A TXV 39,500 14.5 12.5 C33-42 SL280UH090XV48B 8812894EL16XC1-042-230A TXV 41,500 15.5 13 C33-43B EL180UH090E48B 8812895NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 49: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 49

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 41,500 15.5 13 C33-43B EL180UH090XE48B 8812896EL16XC1-042-230A TXV 41,000 15.1 12.5 C33-43B EL296UH045XV36B 8812897EL16XC1-042-230A TXV 41,000 15.1 12.5 C33-43B EL296UH070XV36B 8812898EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-43B SL280UH090V36B 8812899EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-43B SL280UH090V48B 8812900EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-43B SL280UH090XV48B 8812901EL16XC1-042-230A TXV 41,000 15.1 12.5 C33-43B SLP98UH070XV36B 8812902EL16XC1-042-230A TXV 41,000 14.5 12.2 C33-43B 8812904EL16XC1-042-230A TXV 41,500 16 13 C33-43C EL180UH090E60C 8812905EL16XC1-042-230A TXV 41,500 16 13 C33-43C EL180UH110E60C 8812906EL16XC1-042-230A TXV 41,500 16 13 C33-43C EL180UH110XE60C 8812907EL16XC1-042-230A TXV 41,000 16 13 C33-43C EL195UH090XE48C 8812908EL16XC1-042-230A TXV 41,500 16 13 C33-43C EL195UH110XE60C 8812909EL16XC1-042-230A TXV 41,000 16 13 C33-43C EL296UH090XE48C 8812910EL16XC1-042-230A TXV 41,000 15.5 13 C33-43C EL296UH090XV36C 8812911EL16XC1-042-230A TXV 41,500 16 13 C33-43C EL296UH090XV48C 8812912EL16XC1-042-230A TXV 41,500 15.5 13 C33-43C EL296UH090XV60C 8812913EL16XC1-042-230A TXV 41,500 16 13 C33-43C EL296UH110XE60C 8812914EL16XC1-042-230A TXV 41,500 16 13 C33-43C EL296UH110XV48C 8812915EL16XC1-042-230A TXV 41,500 16 13 C33-43C EL296UH110XV60C 8812916EL16XC1-042-230A TXV 41,500 16 13 C33-43C SL280UH090V60C 8812917EL16XC1-042-230A TXV 41,500 16 13 C33-43C SL280UH090XV60C 8812918EL16XC1-042-230A TXV 41,500 16 13 C33-43C SL280UH110V60C 8812919EL16XC1-042-230A TXV 41,500 16 13 C33-43C SL280UH110XV60C 8812920EL16XC1-042-230A TXV 41,000 15.5 13 C33-43C SLP98UH090XV36C 8812921EL16XC1-042-230A TXV 41,500 16 13 C33-43C SLP98UH090XV48C 8812922EL16XC1-042-230A TXV 41,500 15.5 13 C33-43C SLP98UH090XV60C 8812923EL16XC1-042-230A TXV 41,500 16 13 C33-43C SLP98UH110XV60C 8812924EL16XC1-042-230A TXV 41,000 14.5 12.2 C33-43C 8812926EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48B EL180UH090E48B 8812927EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48B EL180UH090XE48B 8812928EL16XC1-042-230A TXV 40,000 14.5 12.2 C33-48B EL296UH045XV36B 8812929EL16XC1-042-230A TXV 40,000 14.5 12.2 C33-48B EL296UH070XV36B 8812930EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48B SL280UH090V36B 8812931EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48B SL280UH090V48B 8812932EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48B SL280UH090XV48B 8812933EL16XC1-042-230A TXV 40,000 14.5 12.2 C33-48B SLP98UH070XV36B 8812934EL16XC1-042-230A TXV 40,500 15.5 13 C33-48C EL180UH090E60C 8812935EL16XC1-042-230A TXV 40,500 15.5 13 C33-48C EL180UH110E60C 8812936EL16XC1-042-230A TXV 40,500 15.5 13 C33-48C EL180UH110XE60C 8812937EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48C EL195UH090XE48C 8812938EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-48C EL195UH110XE60C 8812939EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48C EL296UH090XE48C 8812940EL16XC1-042-230A TXV 40,500 15.1 12.5 C33-48C EL296UH090XV36C 8812941EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48C EL296UH090XV48C 8812942EL16XC1-042-230A TXV 41,000 15.1 12.5 C33-48C EL296UH090XV60C 8812943EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-48C EL296UH110XE60C 8812944EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48C EL296UH110XV48C 8812945EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48C EL296UH110XV60C 8812946NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 50: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 50

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-48C SL280UH090V60C 8812947EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-48C SL280UH090XV60C 8812948EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48C SL280UH110V60C 8812949EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48C SL280UH110XV60C 8812950EL16XC1-042-230A TXV 40,500 15.1 12.5 C33-48C SLP98UH090XV36C 8812951EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48C SLP98UH090XV48C 8812952EL16XC1-042-230A TXV 41,000 15.1 12.5 C33-48C SLP98UH090XV60C 8812953EL16XC1-042-230A TXV 40,500 15.5 12.5 C33-48C SLP98UH110XV60C 8812954EL16XC1-042-230A TXV 42,000 16 13 C33-49 EL180UH090E60C 8812955EL16XC1-042-230A TXV 42,000 16 13 C33-49 EL180UH110E60C 8812956EL16XC1-042-230A TXV 42,000 16 13 C33-49 EL180UH110XE60C 8812957EL16XC1-042-230A TXV 41,500 16 13 C33-49 EL195UH090XE48C 8812958EL16XC1-042-230A TXV 42,000 16 13 C33-49 EL195UH110XE60C 8812959EL16XC1-042-230A TXV 41,500 16 13 C33-49 EL296UH090XE48C 8812960EL16XC1-042-230A TXV 41,500 16 13 C33-49 EL296UH090XV36C 8812961EL16XC1-042-230A TXV 41,500 16 13 C33-49 EL296UH090XV48C 8812962EL16XC1-042-230A TXV 42,000 16 13 C33-49 EL296UH090XV60C 8812963EL16XC1-042-230A TXV 42,000 16 13 C33-49 EL296UH110XE60C 8812964EL16XC1-042-230A TXV 42,000 16 13 C33-49 EL296UH110XV48C 8812965EL16XC1-042-230A TXV 42,000 16 13 C33-49 EL296UH110XV60C 8812966EL16XC1-042-230A TXV 42,000 16 13 C33-49 SL280UH090V60C 8812967EL16XC1-042-230A TXV 42,000 16 13 C33-49 SL280UH090XV60C 8812968EL16XC1-042-230A TXV 42,000 16 13 C33-49 SL280UH110V60C 8812969EL16XC1-042-230A TXV 42,000 16 13 C33-49 SL280UH110XV60C 8812970EL16XC1-042-230A TXV 41,500 16 13 C33-49 SLP98UH090XV36C 8812971EL16XC1-042-230A TXV 41,500 16 13 C33-49 SLP98UH090XV48C 8812972EL16XC1-042-230A TXV 42,000 16 13 C33-49 SLP98UH090XV60C 8812973EL16XC1-042-230A TXV 42,000 16 13 C33-49 SLP98UH110XV60C 8812974EL16XC1-042-230A TXV 41,500 14.5 12.5 C33-49 8812976EL16XC1-042-230A TXV 41,000 16 13 C33-50/60C EL180UH090E60C 8812977EL16XC1-042-230A TXV 41,000 16 13 C33-50/60C EL180UH110E60C 8812978EL16XC1-042-230A TXV 41,000 16 13 C33-50/60C EL180UH110XE60C 8812979EL16XC1-042-230A TXV 41,000 15.5 13 C33-50/60C EL195UH090XE48C 8812980EL16XC1-042-230A TXV 41,500 15.5 12.5 C33-50/60C EL195UH110XE60C 8812981EL16XC1-042-230A TXV 41,000 15.5 13 C33-50/60C EL296UH090XE48C 8812982EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-50/60C EL296UH090XV36C 8812983EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-50/60C EL296UH090XV48C 8812984EL16XC1-042-230A TXV 41,500 15.5 12.5 C33-50/60C EL296UH090XV60C 8812985EL16XC1-042-230A TXV 41,500 15.5 12.5 C33-50/60C EL296UH110XE60C 8812986EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-50/60C EL296UH110XV48C 8812987EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-50/60C EL296UH110XV60C 8812988EL16XC1-042-230A TXV 41,500 15.5 13 C33-50/60C SL280UH090V60C 8812989EL16XC1-042-230A TXV 41,500 15.5 13 C33-50/60C SL280UH090XV60C 8812990EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-50/60C SL280UH110V60C 8812991EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-50/60C SL280UH110XV60C 8812992EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-50/60C SLP98UH090XV36C 8812993EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-50/60C SLP98UH090XV48C 8812994EL16XC1-042-230A TXV 41,500 15.5 12.5 C33-50/60C SLP98UH090XV60C 8812995EL16XC1-042-230A TXV 41,000 15.5 12.5 C33-50/60C SLP98UH110XV60C 8812996NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 51: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 51

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 40,500 14.5 12.2 C33-50/60C 8812998EL16XC1-042-230A TXV 42,000 16 13 C33-60D EL180UH135E60D 8812999EL16XC1-042-230A TXV 42,000 16 13 C33-60D EL195UH135XE60D 8813000EL16XC1-042-230A TXV 42,000 16 13 C33-60D EL296UH135XE60D 8813001EL16XC1-042-230A TXV 42,000 16 13 C33-60D SL280UH135V60D 8813002EL16XC1-042-230A TXV 41,000 14.5 12.2 C33-60D 8813004EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL180UH090E60C 8813005EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL180UH110E60C 8813006EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL180UH110XE60C 8813007EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL195UH090XE48C 8813008EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL195UH110XE60C 8813009EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL296UH090XE48C 8813010EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL296UH090XV36C 8813011EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL296UH090XV48C 8813012EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL296UH090XV60C 8813013EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL296UH110XE60C 8813014EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL296UH110XV48C 8813015EL16XC1-042-230A TXV 42,000 16 13 C33-62C EL296UH110XV60C 8813016EL16XC1-042-230A TXV 42,000 16 13 C33-62C SL280UH090V60C 8813017EL16XC1-042-230A TXV 42,000 16 13 C33-62C SL280UH090XV60C 8813018EL16XC1-042-230A TXV 42,000 16 13 C33-62C SL280UH110V60C 8813019EL16XC1-042-230A TXV 42,000 16 13 C33-62C SL280UH110XV60C 8813020EL16XC1-042-230A TXV 42,000 16 13 C33-62C SLP98UH090XV36C 8813021EL16XC1-042-230A TXV 42,000 16 13 C33-62C SLP98UH090XV48C 8813022EL16XC1-042-230A TXV 42,000 16 13 C33-62C SLP98UH090XV60C 8813023EL16XC1-042-230A TXV 42,000 16 13 C33-62C SLP98UH110XV60C 8813024EL16XC1-042-230A TXV 42,000 15.1 12.5 C33-62C 8813026EL16XC1-042-230A TXV 42,000 16 13 C33-62D EL180UH135E60D 8813027EL16XC1-042-230A TXV 42,000 16 13 C33-62D EL195UH135XE60D 8813028EL16XC1-042-230A TXV 42,000 16 13 C33-62D EL296UH135XE60D 8813029EL16XC1-042-230A TXV 42,000 16 13 C33-62D SL280UH135V60D 8813030EL16XC1-042-230A TXV 41,500 14.5 12.5 C33-62D 8813032EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36B EL180UH090E48B 8813033EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36B EL180UH090XE48B 8813034EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36B SL280UH090V36B 8813035EL16XC1-042-230A TXV 39,500 14.5 12.5 C35-30/36B SL280UH090V48B 8813036EL16XC1-042-230A TXV 39,500 14.5 12.5 C35-30/36B SL280UH090XV48B 8813037EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C EL180UH090E60C 8813038EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C EL180UH110E60C 8813039EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C EL180UH110XE60C 8813040EL16XC1-042-230A TXV 39,000 15.1 12.5 C35-30/36C EL195UH090XE48C 8813041EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C EL195UH110XE60C 8813042EL16XC1-042-230A TXV 39,000 15.1 12.5 C35-30/36C EL296UH090XE48C 8813043EL16XC1-042-230A TXV 39,000 14.5 12.2 C35-30/36C EL296UH090XV36C 8813044EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C EL296UH090XV48C 8813045EL16XC1-042-230A TXV 39,500 14.5 12.5 C35-30/36C EL296UH090XV60C 8813046EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C EL296UH110XE60C 8813047EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C EL296UH110XV60C 8813048EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C SL280UH090V60C 8813049NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 52: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 52

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C SL280UH090XV60C 8813050EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C SL280UH110V60C 8813051EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C SL280UH110XV60C 8813052EL16XC1-042-230A TXV 39,000 14.5 12.2 C35-30/36C SLP98UH090XV36C 8813053EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C SLP98UH090XV48C 8813054EL16XC1-042-230A TXV 39,500 14.5 12.5 C35-30/36C SLP98UH090XV60C 8813055EL16XC1-042-230A TXV 39,500 15.1 12.5 C35-30/36C SLP98UH110XV60C 8813056EL16XC1-042-230A TXV 41,000 15.5 13 C35-36B EL180UH090E48B 8813058EL16XC1-042-230A TXV 41,000 15.5 13 C35-36B EL180UH090XE48B 8813059EL16XC1-042-230A TXV 41,000 15.1 12.5 C35-36B EL296UH045XV36B 8813060EL16XC1-042-230A TXV 41,000 15.1 12.5 C35-36B EL296UH070XV36B 8813061EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-36B SL280UH090V36B 8813062EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-36B SL280UH090V48B 8813063EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-36B SL280UH090XV48B 8813064EL16XC1-042-230A TXV 41,000 15.1 12.5 C35-36B SLP98UH070XV36B 8813065EL16XC1-042-230A TXV 41,000 14.5 12.2 C35-36B 8813066EL16XC1-042-230A TXV 41,500 16 13 C35-48B EL180UH090E48B 8813067EL16XC1-042-230A TXV 41,500 16 13 C35-48B EL180UH090XE48B 8813068EL16XC1-042-230A TXV 41,000 15.1 12.5 C35-48B EL296UH045XV36B 8813069EL16XC1-042-230A TXV 41,000 15.1 12.5 C35-48B EL296UH070XV36B 8813070EL16XC1-042-230A TXV 41,500 15.5 12.5 C35-48B SL280UH090V36B 8813071EL16XC1-042-230A TXV 41,500 15.5 12.5 C35-48B SL280UH090V48B 8813072EL16XC1-042-230A TXV 41,500 15.5 12.5 C35-48B SL280UH090XV48B 8813073EL16XC1-042-230A TXV 41,000 15.1 12.5 C35-48B SLP98UH070XV36B 8813074EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL180UH090E60C 8813077EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL180UH110E60C 8813078EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL180UH110XE60C 8813079EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL195UH090XE48C 8813080EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL195UH110XE60C 8813081EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL296UH090XE48C 8813082EL16XC1-042-230A TXV 41,500 15.5 13 C35-48C EL296UH090XV36C 8813083EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL296UH090XV48C 8813084EL16XC1-042-230A TXV 41,500 15.5 13 C35-48C EL296UH090XV60C 8813085EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL296UH110XE60C 8813086EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL296UH110XV48C 8813087EL16XC1-042-230A TXV 41,500 16 13 C35-48C EL296UH110XV60C 8813088EL16XC1-042-230A TXV 42,000 16 13 C35-48C SL280UH090V60C 8813089EL16XC1-042-230A TXV 42,000 16 13 C35-48C SL280UH090XV60C 8813090EL16XC1-042-230A TXV 41,500 16 13 C35-48C SL280UH110V60C 8813091EL16XC1-042-230A TXV 41,500 16 13 C35-48C SL280UH110XV60C 8813092EL16XC1-042-230A TXV 41,500 15.5 13 C35-48C SLP98UH090XV36C 8813093EL16XC1-042-230A TXV 41,500 16 13 C35-48C SLP98UH090XV48C 8813094EL16XC1-042-230A TXV 41,500 15.5 13 C35-48C SLP98UH090XV60C 8813095EL16XC1-042-230A TXV 41,500 16 13 C35-48C SLP98UH110XV60C 8813096EL16XC1-042-230A TXV 41,000 14.5 12.2 C35-48C 8813076EL16XC1-042-230A TXV 42,000 16 13 C35-49C EL180UH090E60C 8813097EL16XC1-042-230A TXV 42,000 16 13 C35-49C EL180UH110E60C 8813098EL16XC1-042-230A TXV 42,000 16 13 C35-49C EL180UH110XE60C 8813099EL16XC1-042-230A TXV 41,500 16 13 C35-49C EL195UH090XE48C 8813100NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 53: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 53

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 42,000 16 13 C35-49C EL195UH110XE60C 8813101EL16XC1-042-230A TXV 41,500 16 13 C35-49C EL296UH090XE48C 8813102EL16XC1-042-230A TXV 41,500 16 13 C35-49C EL296UH090XV36C 8813103EL16XC1-042-230A TXV 41,500 16 13 C35-49C EL296UH090XV48C 8813104EL16XC1-042-230A TXV 42,000 16 13 C35-49C EL296UH090XV60C 8813105EL16XC1-042-230A TXV 42,000 16 13 C35-49C EL296UH110XE60C 8813106EL16XC1-042-230A TXV 42,000 16 13 C35-49C EL296UH110XV48C 8813107EL16XC1-042-230A TXV 42,000 16 13 C35-49C EL296UH110XV60C 8813108EL16XC1-042-230A TXV 42,000 16 13 C35-49C SL280UH090V60C 8813109EL16XC1-042-230A TXV 42,000 16 13 C35-49C SL280UH090XV60C 8813110EL16XC1-042-230A TXV 42,000 16 13 C35-49C SL280UH110V60C 8813111EL16XC1-042-230A TXV 42,000 16 13 C35-49C SL280UH110XV60C 8813112EL16XC1-042-230A TXV 41,500 16 13 C35-49C SLP98UH090XV36C 8813113EL16XC1-042-230A TXV 41,500 16 13 C35-49C SLP98UH090XV48C 8813114EL16XC1-042-230A TXV 42,000 16 13 C35-49C SLP98UH090XV60C 8813115EL16XC1-042-230A TXV 42,000 16 13 C35-49C SLP98UH110XV60C 8813116EL16XC1-042-230A TXV 41,500 14.5 12.5 C35-49C 8813118EL16XC1-042-230A TXV 41,000 16 13 C35-50/60C EL180UH090E60C 8813119EL16XC1-042-230A TXV 41,000 16 13 C35-50/60C EL180UH110E60C 8813120EL16XC1-042-230A TXV 41,000 16 13 C35-50/60C EL180UH110XE60C 8813121EL16XC1-042-230A TXV 41,000 15.5 13 C35-50/60C EL195UH090XE48C 8813122EL16XC1-042-230A TXV 41,500 15.5 12.5 C35-50/60C EL195UH110XE60C 8813123EL16XC1-042-230A TXV 41,000 15.5 13 C35-50/60C EL296UH090XE48C 8813124EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-50/60C EL296UH090XV36C 8813125EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-50/60C EL296UH090XV48C 8813126EL16XC1-042-230A TXV 41,500 15.5 12.5 C35-50/60C EL296UH090XV60C 8813127EL16XC1-042-230A TXV 41,500 15.5 12.5 C35-50/60C EL296UH110XE60C 8813128EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-50/60C EL296UH110XV48C 8813129EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-50/60C EL296UH110XV60C 8813130EL16XC1-042-230A TXV 41,500 15.5 13 C35-50/60C SL280UH090V60C 8813131EL16XC1-042-230A TXV 41,500 15.5 13 C35-50/60C SL280UH090XV60C 8813132EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-50/60C SL280UH110V60C 8813133EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-50/60C SL280UH110XV60C 8813134EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-50/60C SLP98UH090XV36C 8813135EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-50/60C SLP98UH090XV48C 8813136EL16XC1-042-230A TXV 41,500 15.5 12.5 C35-50/60C SLP98UH090XV60C 8813137EL16XC1-042-230A TXV 41,000 15.5 12.5 C35-50/60C SLP98UH110XV60C 8813138EL16XC1-042-230A TXV 40,500 14.5 12.2 C35-50/60C 8813139EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL180UH090E60C 8813140EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL180UH110E60C 8813141EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL180UH110XE60C 8813142EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL195UH090XE48C 8813143EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL195UH110XE60C 8813144EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL296UH090XE48C 8813145EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL296UH090XV36C 8813146EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL296UH090XV48C 8813147EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL296UH090XV60C 8813148EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL296UH110XE60C 8813149EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL296UH110XV48C 8813150NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 54: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 54

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 42,000 16 13 C35-60C EL296UH110XV60C 8813151EL16XC1-042-230A TXV 42,000 16 13 C35-60C SL280UH090V60C 8813152EL16XC1-042-230A TXV 42,000 16 13 C35-60C SL280UH090XV60C 8813153EL16XC1-042-230A TXV 42,000 16 13 C35-60C SL280UH110V60C 8813154EL16XC1-042-230A TXV 42,000 16 13 C35-60C SL280UH110XV60C 8813155EL16XC1-042-230A TXV 42,000 16 13 C35-60C SLP98UH090XV36C 8813156EL16XC1-042-230A TXV 42,000 16 13 C35-60C SLP98UH090XV48C 8813157EL16XC1-042-230A TXV 42,000 16 13 C35-60C SLP98UH090XV60C 8813158EL16XC1-042-230A TXV 42,000 16 13 C35-60C SLP98UH110XV60C 8813159EL16XC1-042-230A TXV 42,000 15.1 12.5 C35-60C 8813161EL16XC1-042-230A TXV 42,000 16 13 C35-60D EL180UH135E60D 8813163EL16XC1-042-230A TXV 42,000 16 13 C35-60D EL195UH135XE60D 8813164EL16XC1-042-230A TXV 42,000 16 13 C35-60D EL296UH135XE60D 8813165EL16XC1-042-230A TXV 42,000 16 13 C35-60D SL280UH135V60D 8813166EL16XC1-042-230A TXV 41,500 14.5 12.5 C35-60D 8813167EL16XC1-042-230A TXV 42,000 16 13 CBA27UHE-042 10259412EL16XC1-042-230A TXV 42,000 16 13 CBA27UHE-048 10259413EL16XC1-042-230A TXV 41,000 15.1 12.5 CBX25UH-042 8813168EL16XC1-042-230A TXV 41,500 15.5 12.5 CBX25UH-048 8813169EL16XC1-042-230A TXV 41,500 16 13 CBX25UHV-042 8813170EL16XC1-042-230A TXV 42,000 16 13 CBX25UHV-048 8813171EL16XC1-042-230A TXV 42,000 16 13 CBX27UH-042 8813172EL16XC1-042-230A TXV 41,500 16 13 CBX27UH-048 8813173EL16XC1-042-230A TXV 40,000 14.5 12.5 CBX32M-042 8813174EL16XC1-042-230A TXV 41,500 15.1 12.5 CBX32M-048 8813175EL16XC1-042-230A TXV 42,000 16 13 CBX32MV-048 8813176EL16XC1-042-230A TXV 41,500 16 13 CBX40UHV-042 8813177EL16XC1-042-230A TXV 42,000 16 13 CBX40UHV-048 8813178EL16XC1-042-230A TXV 40,000 15.1 12.5 CH23-51 EL180UH090E48C 10260329EL16XC1-042-230A TXV 40,500 15.5 12.5 CH23-51 EL180UH090E60C 8813179EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 EL180UH110E60C 8813180EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 EL180UH110XE60C 8813181EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 EL296UH090XV48C 8813182EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 EL296UH090XV60C 8813183EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 EL296UH110XV48C 8813184EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 EL296UH110XV60C 8813185EL16XC1-042-230A TXV 40,500 15.5 12.5 CH23-51 SL280UH090V60C 8813186EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 SL280UH110V60C 8813187EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 SL280UH110XV60C 8813188EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 SLP98UH090XV48C 8813189EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 SLP98UH090XV60C 8813190EL16XC1-042-230A TXV 40,000 15.5 12.5 CH23-51 SLP98UH110XV60C 8813191EL16XC1-042-230A TXV 40,500 16 13 CH23-65 EL180UH090E60C 8813192EL16XC1-042-230A TXV 40,500 15.5 13 CH23-65 EL180UH110E60C 8813193EL16XC1-042-230A TXV 40,500 15.5 13 CH23-65 EL180UH110XE60C 8813194EL16XC1-042-230A TXV 40,500 15.5 12.5 CH23-65 EL296UH090XV48C 8813195EL16XC1-042-230A TXV 40,500 15.5 12.5 CH23-65 EL296UH090XV60C 8813196EL16XC1-042-230A TXV 40,500 15.5 12.5 CH23-65 EL296UH110XV48C 8813197EL16XC1-042-230A TXV 40,500 15.5 12.5 CH23-65 EL296UH110XV60C 8813198NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 55: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 55

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 41,000 16 13 CH23-65 SL280UH090V60C 8813199EL16XC1-042-230A TXV 40,500 15.5 13 CH23-65 SL280UH110V60C 8813200EL16XC1-042-230A TXV 40,500 15.5 13 CH23-65 SL280UH110XV60C 8813201EL16XC1-042-230A TXV 40,500 15.5 12.5 CH23-65 SLP98UH090XV48C 8813202EL16XC1-042-230A TXV 40,500 15.5 12.5 CH23-65 SLP98UH090XV60C 8813203EL16XC1-042-230A TXV 40,500 15.5 12.5 CH23-65 SLP98UH110XV60C 8813204EL16XC1-042-230A TXV 40,500 15.5 12.5 CH33-42 EL180UH090E48B 8813205EL16XC1-042-230A TXV 40,500 15.5 12.5 CH33-42 EL180UH090XE48B 8813206EL16XC1-042-230A TXV 40,000 14.5 12.2 CH33-42 EL296UH070XV36B 8813207EL16XC1-042-230A TXV 40,500 15.5 12.5 CH33-42 SL280UH090V36B 8813208EL16XC1-042-230A TXV 40,500 15.1 12.5 CH33-42 SL280UH090V48B 8813209EL16XC1-042-230A TXV 40,500 15.1 12.5 CH33-42 SL280UH090XV48B 8813210EL16XC1-042-230A TXV 40,000 14.5 12.2 CH33-42 SLP98UH070XV36B 8813211EL16XC1-042-230A TXV 42,000 16 13 CH33-43B EL180UH090E48B 8813212EL16XC1-042-230A TXV 42,000 16 13 CH33-43B EL180UH090XE48B 8813213EL16XC1-042-230A TXV 41,500 15.5 12.5 CH33-43B EL296UH045XV36B 8813214EL16XC1-042-230A TXV 41,500 15.1 12.5 CH33-43B EL296UH070XV36B 8813215EL16XC1-042-230A TXV 42,000 16 13 CH33-43B SL280UH090V36B 8813216EL16XC1-042-230A TXV 42,000 16 13 CH33-43B SL280UH090V48B 8813217EL16XC1-042-230A TXV 42,000 16 13 CH33-43B SL280UH090XV48B 8813218EL16XC1-042-230A TXV 41,500 15.1 12.5 CH33-43B SLP98UH070XV36B 8813219EL16XC1-042-230A TXV 41,500 16 13 CH33-43C EL180UH090E60C 8813220EL16XC1-042-230A TXV 41,500 16 13 CH33-43C EL180UH110E60C 8813221EL16XC1-042-230A TXV 41,500 16 13 CH33-43C EL180UH110XE60C 8813222EL16XC1-042-230A TXV 41,000 16 13 CH33-43C EL195UH090XE48C 8813223EL16XC1-042-230A TXV 41,500 16 13 CH33-43C EL195UH110XE60C 8813224EL16XC1-042-230A TXV 41,000 16 13 CH33-43C EL296UH090XE48C 8813225EL16XC1-042-230A TXV 41,500 15.5 13 CH33-43C EL296UH090XV36C 8813226EL16XC1-042-230A TXV 41,500 16 13 CH33-43C EL296UH090XV48C 8813227EL16XC1-042-230A TXV 41,500 16 13 CH33-43C EL296UH090XV60C 8813228EL16XC1-042-230A TXV 41,500 16 13 CH33-43C EL296UH110XE60C 8813229EL16XC1-042-230A TXV 41,500 16 13 CH33-43C EL296UH110XV48C 8813230EL16XC1-042-230A TXV 41,500 16 13 CH33-43C EL296UH110XV60C 8813231EL16XC1-042-230A TXV 42,000 16 13 CH33-43C SL280UH090V60C 8813232EL16XC1-042-230A TXV 42,000 16 13 CH33-43C SL280UH090XV60C 8813233EL16XC1-042-230A TXV 41,500 16 13 CH33-43C SL280UH110V60C 8813234EL16XC1-042-230A TXV 41,500 16 13 CH33-43C SL280UH110XV60C 8813235EL16XC1-042-230A TXV 41,500 15.5 13 CH33-43C SLP98UH090XV36C 8813236EL16XC1-042-230A TXV 41,500 16 13 CH33-43C SLP98UH090XV48C 8813237EL16XC1-042-230A TXV 41,500 16 13 CH33-43C SLP98UH090XV60C 8813238EL16XC1-042-230A TXV 41,500 16 13 CH33-43C SLP98UH110XV60C 8813239EL16XC1-042-230A TXV 41,000 14.5 12.2 CH33-43C 8813241EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-44/48B EL180UH090E48B 8813242EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-44/48B EL180UH090XE48B 8813243EL16XC1-042-230A TXV 40,500 14.5 12.5 CH33-44/48B EL296UH070XV36B 8813244EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-44/48B SL280UH090V36B 8813245EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-44/48B SL280UH090V48B 8813246EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-44/48B SL280UH090XV48B 8813247EL16XC1-042-230A TXV 40,500 14.5 12.5 CH33-44/48B SLP98UH070XV36B 9150355NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 56: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 56

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 41,000 16 13 CH33-48C EL180UH090E60C 8813249EL16XC1-042-230A TXV 41,000 16 13 CH33-48C EL180UH110E60C 8813250EL16XC1-042-230A TXV 41,000 16 13 CH33-48C EL180UH110XE60C 8813251EL16XC1-042-230A TXV 41,000 15.5 13 CH33-48C EL195UH090XE48C 8813252EL16XC1-042-230A TXV 41,500 15.5 12.5 CH33-48C EL195UH110XE60C 8813253EL16XC1-042-230A TXV 41,000 15.5 13 CH33-48C EL296UH090XE48C 8813254EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-48C EL296UH090XV36C 8813255EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-48C EL296UH090XV48C 8813256EL16XC1-042-230A TXV 41,500 15.5 12.5 CH33-48C EL296UH090XV60C 8813257EL16XC1-042-230A TXV 41,500 15.5 12.5 CH33-48C EL296UH110XE60C 8813258EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-48C EL296UH110XV48C 8813259EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-48C EL296UH110XV60C 8813260EL16XC1-042-230A TXV 41,500 15.5 13 CH33-48C SL280UH090V60C 8813261EL16XC1-042-230A TXV 41,500 15.5 13 CH33-48C SL280UH090XV60C 8813262EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-48C SL280UH110V60C 8813263EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-48C SL280UH110XV60C 8813264EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-48C SLP98UH090XV36C 8813265EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-48C SLP98UH090XV48C 8813266EL16XC1-042-230A TXV 41,500 15.5 12.5 CH33-48C SLP98UH090XV60C 8813267EL16XC1-042-230A TXV 41,000 15.5 12.5 CH33-48C SLP98UH110XV60C 8813268EL16XC1-042-230A TXV 42,000 16 13 CH33-49 EL180UH090E60C 8813269EL16XC1-042-230A TXV 42,000 16 13 CH33-49 EL180UH110E60C 8813270EL16XC1-042-230A TXV 42,000 16 13 CH33-49 EL180UH110XE60C 8813271EL16XC1-042-230A TXV 41,500 16 13 CH33-49 EL195UH090XE48C 8813272EL16XC1-042-230A TXV 42,000 16 13 CH33-49 EL195UH110XE60C 8813273EL16XC1-042-230A TXV 41,500 16 13 CH33-49 EL296UH090XE48C 8813274EL16XC1-042-230A TXV 41,500 15.5 13 CH33-49 EL296UH090XV36C 8813275EL16XC1-042-230A TXV 42,000 16 13 CH33-49 EL296UH090XV48C 8813276EL16XC1-042-230A TXV 42,000 15.5 13 CH33-49 EL296UH090XV60C 8813277EL16XC1-042-230A TXV 42,000 16 13 CH33-49 EL296UH110XE60C 8813278EL16XC1-042-230A TXV 42,000 16 13 CH33-49 EL296UH110XV48C 8813279EL16XC1-042-230A TXV 42,000 16 13 CH33-49 EL296UH110XV60C 8813280EL16XC1-042-230A TXV 42,000 16 13 CH33-49 SL280UH090V60C 8813281EL16XC1-042-230A TXV 42,000 16 13 CH33-49 SL280UH090XV60C 8813282EL16XC1-042-230A TXV 42,000 16 13 CH33-49 SL280UH110V60C 8813283EL16XC1-042-230A TXV 42,000 16 13 CH33-49 SL280UH110XV60C 8813284EL16XC1-042-230A TXV 41,500 15.5 13 CH33-49 SLP98UH090XV36C 8813285EL16XC1-042-230A TXV 42,000 16 13 CH33-49 SLP98UH090XV48C 8813286EL16XC1-042-230A TXV 42,000 15.5 13 CH33-49 SLP98UH090XV60C 8813287EL16XC1-042-230A TXV 42,000 16 13 CH33-49 SLP98UH110XV60C 8813288EL16XC1-042-230A TXV 41,500 14.5 12.5 CH33-49 8813290EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C EL180UH090E60C 8813291EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C EL180UH110E60C 8813292EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C EL180UH110XE60C 8813293EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C EL195UH090XE48C 8813294EL16XC1-042-230A TXV 42,000 16 13 CH33-50/60C EL195UH110XE60C 8813295EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C EL296UH090XE48C 8813296EL16XC1-042-230A TXV 41,500 15.5 12.5 CH33-50/60C EL296UH090XV36C 8813297EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C EL296UH090XV48C 8813298NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 57: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 57

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 42,000 15.5 12.5 CH33-50/60C EL296UH090XV60C 8813299EL16XC1-042-230A TXV 42,000 16 13 CH33-50/60C EL296UH110XE60C 8813300EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C EL296UH110XV48C 8813301EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C EL296UH110XV60C 8813302EL16XC1-042-230A TXV 42,000 16 13 CH33-50/60C SL280UH090V60C 8813303EL16XC1-042-230A TXV 42,000 16 13 CH33-50/60C SL280UH090XV60C 8813304EL16XC1-042-230A TXV 41,500 15.5 13 CH33-50/60C SL280UH110V60C 8813305EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C SL280UH110XV60C 8813306EL16XC1-042-230A TXV 41,500 15.5 12.5 CH33-50/60C SLP98UH090XV36C 8813307EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C SLP98UH090XV48C 8813308EL16XC1-042-230A TXV 42,000 15.5 12.5 CH33-50/60C SLP98UH090XV60C 8813309EL16XC1-042-230A TXV 41,500 16 13 CH33-50/60C SLP98UH110XV60C 8813310EL16XC1-042-230A TXV 41,000 14.5 12.2 CH33-50/60C 8813312EL16XC1-042-230A TXV 42,000 16 13 CH35-42B EL180UH090E48B 8813313EL16XC1-042-230A TXV 42,000 16 13 CH35-42B EL180UH090XE48B 8813314EL16XC1-042-230A TXV 41,500 15.5 12.5 CH35-42B EL296UH045XV36B 8813315EL16XC1-042-230A TXV 41,500 15.1 12.5 CH35-42B EL296UH070XV36B 8813316EL16XC1-042-230A TXV 42,000 16 13 CH35-42B SL280UH090V36B 8813317EL16XC1-042-230A TXV 42,000 16 13 CH35-42B SL280UH090V48B 8813318EL16XC1-042-230A TXV 42,000 16 13 CH35-42B SL280UH090XV48B 8813319EL16XC1-042-230A TXV 41,500 15.1 12.5 CH35-42B SLP98UH070XV36B 8813320EL16XC1-042-230A TXV 41,500 16 13 CH35-42C EL180UH090E60C 8813321EL16XC1-042-230A TXV 41,500 16 13 CH35-42C EL180UH110E60C 8813322EL16XC1-042-230A TXV 41,500 16 13 CH35-42C EL180UH110XE60C 8813323EL16XC1-042-230A TXV 41,500 16 13 CH35-42C EL195UH090XE48C 8813324EL16XC1-042-230A TXV 42,000 16 13 CH35-42C EL195UH110XE60C 8813325EL16XC1-042-230A TXV 41,500 16 13 CH35-42C EL296UH090XE48C 8813326EL16XC1-042-230A TXV 41,500 16 13 CH35-42C EL296UH090XV36C 8813327EL16XC1-042-230A TXV 41,500 16 13 CH35-42C EL296UH090XV48C 8813328EL16XC1-042-230A TXV 42,000 16 13 CH35-42C EL296UH090XV60C 8813329EL16XC1-042-230A TXV 42,000 16 13 CH35-42C EL296UH110XE60C 8813330EL16XC1-042-230A TXV 41,500 16 13 CH35-42C EL296UH110XV48C 8813331EL16XC1-042-230A TXV 41,500 16 13 CH35-42C EL296UH110XV60C 8813332EL16XC1-042-230A TXV 42,000 16 13 CH35-42C SL280UH090V60C 8813333EL16XC1-042-230A TXV 42,000 16 13 CH35-42C SL280UH090XV60C 8813334EL16XC1-042-230A TXV 41,500 16 13 CH35-42C SL280UH110V60C 8813335EL16XC1-042-230A TXV 41,500 16 13 CH35-42C SL280UH110XV60C 8813336EL16XC1-042-230A TXV 41,500 16 13 CH35-42C SLP98UH090XV36C 8813337EL16XC1-042-230A TXV 41,500 16 13 CH35-42C SLP98UH090XV48C 8813338EL16XC1-042-230A TXV 42,000 16 13 CH35-42C SLP98UH090XV60C 8813339EL16XC1-042-230A TXV 41,500 16 13 CH35-42C SLP98UH110XV60C 8813340EL16XC1-042-230A TXV 41,000 14.25 12.2 CH35-42C 8813341EL16XC1-042-230A TXV 41,500 15.5 13 CH35-48B EL180UH090E48B 8813342EL16XC1-042-230A TXV 41,500 15.5 13 CH35-48B EL180UH090XE48B 8813343EL16XC1-042-230A TXV 41,000 15.1 12.5 CH35-48B EL296UH045XV36B 8813344EL16XC1-042-230A TXV 41,000 15.1 12.5 CH35-48B EL296UH070XV36B 8813345EL16XC1-042-230A TXV 41,500 15.5 12.5 CH35-48B SL280UH090V36B 8813346EL16XC1-042-230A TXV 41,500 15.5 12.5 CH35-48B SL280UH090V48B 8813347EL16XC1-042-230A TXV 41,500 15.5 12.5 CH35-48B SL280UH090XV48B 8813348NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 58: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 58

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 41,000 15.1 12.5 CH35-48B SLP98UH070XV36B 8813349EL16XC1-042-230A TXV 41,500 16 13 CH35-48C EL180UH090E60C 8813350EL16XC1-042-230A TXV 41,500 16 13 CH35-48C EL180UH110E60C 8813351EL16XC1-042-230A TXV 41,500 16 13 CH35-48C EL180UH110XE60C 8813352EL16XC1-042-230A TXV 41,000 15.5 13 CH35-48C EL195UH090XE48C 8813353EL16XC1-042-230A TXV 41,500 15.5 13 CH35-48C EL195UH110XE60C 8813354EL16XC1-042-230A TXV 41,000 15.5 13 CH35-48C EL296UH090XE48C 8813355EL16XC1-042-230A TXV 41,000 15.5 12.5 CH35-48C EL296UH090XV36C 8813356EL16XC1-042-230A TXV 41,500 15.5 13 CH35-48C EL296UH090XV48C 8813357EL16XC1-042-230A TXV 41,500 15.5 12.5 CH35-48C EL296UH090XV60C 8813358EL16XC1-042-230A TXV 41,500 15.5 13 CH35-48C EL296UH110XE60C 8813359EL16XC1-042-230A TXV 41,500 15.5 13 CH35-48C EL296UH110XV48C 8813360EL16XC1-042-230A TXV 41,500 15.5 13 CH35-48C EL296UH110XV60C 8813361EL16XC1-042-230A TXV 41,500 16 13 CH35-48C SL280UH090V60C 8813362EL16XC1-042-230A TXV 41,500 16 13 CH35-48C SL280UH090XV60C 8813363EL16XC1-042-230A TXV 41,500 15.5 12.5 CH35-48C SL280UH110V60C 8813364EL16XC1-042-230A TXV 41,500 15.5 12.5 CH35-48C SL280UH110XV60C 8813365EL16XC1-042-230A TXV 41,000 15.5 12.5 CH35-48C SLP98UH090XV36C 8813366EL16XC1-042-230A TXV 41,500 15.5 13 CH35-48C SLP98UH090XV48C 8813367EL16XC1-042-230A TXV 41,500 15.5 12.5 CH35-48C SLP98UH090XV60C 8813368EL16XC1-042-230A TXV 41,500 15.5 13 CH35-48C SLP98UH110XV60C 8813369EL16XC1-042-230A TXV 41,000 14.25 12.2 CH35-48C 8813370EL16XC1-042-230A TXV 42,000 16 13 CH35-51C EL180UH090E60C 8813371EL16XC1-042-230A TXV 42,000 16 13 CH35-51C EL180UH110E60C 8813372EL16XC1-042-230A TXV 42,000 16 13 CH35-51C EL180UH110XE60C 8813373EL16XC1-042-230A TXV 41,500 16 13 CH35-51C EL195UH090XE48C 8813374EL16XC1-042-230A TXV 42,000 16 13 CH35-51C EL195UH110XE60C 8813375EL16XC1-042-230A TXV 41,500 16 13 CH35-51C EL296UH090XE48C 8813376EL16XC1-042-230A TXV 41,500 15.5 13 CH35-51C EL296UH090XV36C 8813377EL16XC1-042-230A TXV 42,000 16 13 CH35-51C EL296UH090XV48C 8813378EL16XC1-042-230A TXV 42,000 15.5 13 CH35-51C EL296UH090XV60C 8813379EL16XC1-042-230A TXV 42,000 16 13 CH35-51C EL296UH110XE60C 8813380EL16XC1-042-230A TXV 42,000 16 13 CH35-51C EL296UH110XV48C 8813381EL16XC1-042-230A TXV 42,000 16 13 CH35-51C EL296UH110XV60C 8813382EL16XC1-042-230A TXV 42,000 16 13 CH35-51C SL280UH090V60C 8813383EL16XC1-042-230A TXV 42,000 16 13 CH35-51C SL280UH090XV60C 8813384EL16XC1-042-230A TXV 42,000 16 13 CH35-51C SL280UH110V60C 8813385EL16XC1-042-230A TXV 42,000 16 13 CH35-51C SL280UH110XV60C 8813386EL16XC1-042-230A TXV 41,500 15.5 13 CH35-51C SLP98UH090XV36C 8813387EL16XC1-042-230A TXV 42,000 16 13 CH35-51C SLP98UH090XV48C 8813388EL16XC1-042-230A TXV 42,000 15.5 13 CH35-51C SLP98UH090XV60C 8813389EL16XC1-042-230A TXV 42,000 16 13 CH35-51C SLP98UH110XV60C 8813390EL16XC1-042-230A TXV 41,500 14.5 12.5 CH35-51C 8813391EL16XC1-042-230A TXV 40,500 15.5 12.5 CR33-48 EL180DF110E60C 8813393EL16XC1-042-230A TXV 40,500 15.5 12.5 CR33-48 EL195DF090XE48C 8813394EL16XC1-042-230A TXV 40,500 15.5 12.5 CR33-48 EL195DF110XE60C 8813395EL16XC1-042-230A TXV 40,500 15.5 12.5 CR33-48 EL296DF090XE48C 8813396EL16XC1-042-230A TXV 40,500 15.1 12.5 CR33-48 EL296DF090XV60C 8813397EL16XC1-042-230A TXV 40,500 15.5 12.5 CR33-48 EL296DF110XE60C 8813398NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 59: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 59

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 40,500 15.1 12.5 CR33-48 SL280DF090V48B 8813392EL16XC1-042-230A TXV 40,500 15.5 12.5 CR33-48 SL280DF090V60C 8813399EL16XC1-042-230A TXV 40,500 15.5 12.5 CR33-48 SL280DF110V60C 8813400EL16XC1-042-230A TXV 40,500 15.1 12.5 CR33-48 SLP98DF090XV48C 8813401EL16XC1-042-230A TXV 40,500 15.1 12.5 CR33-48 SLP98DF090XV60C 8813402EL16XC1-042-230A TXV 41,500 16 13 CR33-50/60 EL180DF110E60C 8813403EL16XC1-042-230A TXV 41,000 15.5 13 CR33-50/60 EL195DF090XE48C 8813404EL16XC1-042-230A TXV 41,500 16 13 CR33-50/60 EL195DF110XE60C 8813405EL16XC1-042-230A TXV 41,000 15.5 13 CR33-50/60 EL296DF090XE48C 8813406EL16XC1-042-230A TXV 41,500 15.5 12.5 CR33-50/60 EL296DF090XV60C 8813407EL16XC1-042-230A TXV 41,500 16 13 CR33-50/60 EL296DF110XE60C 8813408EL16XC1-042-230A TXV 41,500 16 13 CR33-50/60 EL296DF110XV60C 8813409EL16XC1-042-230A TXV 41,500 16 13 CR33-50/60 SL280DF090V60C 8813410EL16XC1-042-230A TXV 41,500 16 13 CR33-50/60 SL280DF110V60C 8813411EL16XC1-042-230A TXV 41,000 15.5 12.5 CR33-50/60 SLP98DF090XV36C 8813412EL16XC1-042-230A TXV 41,500 15.5 12.5 CR33-50/60 SLP98DF090XV48C 8813413EL16XC1-042-230A TXV 41,500 15.5 12.5 CR33-50/60 SLP98DF090XV60C 8813414EL16XC1-042-230A TXV 41,500 16 13 CR33-50/60 SLP98DF110XV60C 8813415EL16XC1-042-230A TXV 40,500 14.5 12.2 CR33-50/60 10238966EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-36B EL180UH090E48B 8813416EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-36B EL180UH090XE48B 8813417EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-36B SL280UH090V36B 8813418EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-36B SL280UH090V48B 8813419EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-36B SL280UH090XV48B 8813420EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-36C EL180UH090E60C 8813421EL16XC1-042-230A TXV 39,000 15.1 12.5 CX34-36C EL180UH110E60C 8813422EL16XC1-042-230A TXV 39,000 15.1 12.5 CX34-36C EL180UH110XE60C 8813423EL16XC1-042-230A TXV 39,000 15.1 12.5 CX34-36C EL195UH090XE48C 8813424EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-36C EL195UH110XE60C 8813425EL16XC1-042-230A TXV 39,000 15.1 12.5 CX34-36C EL296UH090XE48C 8813426EL16XC1-042-230A TXV 39,000 14.5 12.2 CX34-36C EL296UH090XV36C 8813427EL16XC1-042-230A TXV 39,000 15.1 12.5 CX34-36C EL296UH090XV48C 8813428EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-36C EL296UH090XV60C 8813429EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-36C EL296UH110XE60C 8813430EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-36C EL296UH110XV60C 8813431EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-36C SL280UH090V60C 8813432EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-36C SL280UH090XV60C 8813433EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-36C SL280UH110V60C 8813434EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-36C SL280UH110XV60C 8813435EL16XC1-042-230A TXV 39,000 14.5 12.2 CX34-36C SLP98UH090XV36C 8813436EL16XC1-042-230A TXV 39,000 15.1 12.5 CX34-36C SLP98UH090XV48C 8813437EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-36C SLP98UH090XV60C 8813438EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-36C SLP98UH110XV60C 8813439EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-38B EL180UH090E48B 8813440EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-38B EL180UH090XE48B 8813441EL16XC1-042-230A TXV 40,500 15.1 12.5 CX34-38B EL296UH045XV36B 8813442EL16XC1-042-230A TXV 40,500 14.5 12.5 CX34-38B EL296UH070XV36B 8813443EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-38B SL280UH090V36B 8813444EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-38B SL280UH090V48B 8813445NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 60: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 60

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-38B SL280UH090XV48B 8813446EL16XC1-042-230A TXV 40,500 14.5 12.5 CX34-38B SLP98UH070XV36B 8813447EL16XC1-042-230A TXV 40,500 14.5 12.2 CX34-38B 8813448EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-42 EL180UH090E48B 8813449EL16XC1-042-230A TXV 39,500 15.1 12.5 CX34-42 EL180UH090XE48B 8813450EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-42 SL280UH090V36B 8813451EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-42 SL280UH090V48B 8813452EL16XC1-042-230A TXV 39,500 14.5 12.5 CX34-42 SL280UH090XV48B 8813453EL16XC1-042-230A TXV 41,500 15.5 13 CX34-43B EL180UH090E48B 8813454EL16XC1-042-230A TXV 41,500 15.5 13 CX34-43B EL180UH090XE48B 8813455EL16XC1-042-230A TXV 41,000 15.1 12.5 CX34-43B EL296UH045XV36B 8813456EL16XC1-042-230A TXV 41,000 15.1 12.5 CX34-43B EL296UH070XV36B 8813457EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-43B SL280UH090V36B 8813458EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-43B SL280UH090V48B 8813459EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-43B SL280UH090XV48B 8813460EL16XC1-042-230A TXV 41,000 15.1 12.5 CX34-43B SLP98UH070XV36B 8813461EL16XC1-042-230A TXV 41,000 14.5 12.2 CX34-43B 8813462EL16XC1-042-230A TXV 41,500 16 13 CX34-43C EL180UH090E60C 8813463EL16XC1-042-230A TXV 41,500 16 13 CX34-43C EL180UH110E60C 8813464EL16XC1-042-230A TXV 41,500 16 13 CX34-43C EL180UH110XE60C 8813465EL16XC1-042-230A TXV 41,000 16 13 CX34-43C EL195UH090XE48C 8813466EL16XC1-042-230A TXV 41,500 16 13 CX34-43C EL195UH110XE60C 8813467EL16XC1-042-230A TXV 41,000 16 13 CX34-43C EL296UH090XE48C 8813468EL16XC1-042-230A TXV 41,000 15.5 13 CX34-43C EL296UH090XV36C 8813469EL16XC1-042-230A TXV 41,500 16 13 CX34-43C EL296UH090XV48C 8813470EL16XC1-042-230A TXV 41,500 15.5 13 CX34-43C EL296UH090XV60C 8813471EL16XC1-042-230A TXV 41,500 16 13 CX34-43C EL296UH110XE60C 8813472EL16XC1-042-230A TXV 41,500 16 13 CX34-43C EL296UH110XV48C 8813473EL16XC1-042-230A TXV 41,500 16 13 CX34-43C EL296UH110XV60C 8813474EL16XC1-042-230A TXV 41,500 16 13 CX34-43C SL280UH090V60C 8813475EL16XC1-042-230A TXV 41,500 16 13 CX34-43C SL280UH090XV60C 8813476EL16XC1-042-230A TXV 41,500 15.5 13 CX34-43C SL280UH110V60C 8813477EL16XC1-042-230A TXV 41,500 15.5 13 CX34-43C SL280UH110XV60C 8813478EL16XC1-042-230A TXV 41,000 15.5 13 CX34-43C SLP98UH090XV36C 8813479EL16XC1-042-230A TXV 41,500 16 13 CX34-43C SLP98UH090XV48C 8813480EL16XC1-042-230A TXV 41,500 15.5 13 CX34-43C SLP98UH090XV60C 8813481EL16XC1-042-230A TXV 41,500 16 13 CX34-43C SLP98UH110XV60C 8813482EL16XC1-042-230A TXV 41,000 14.5 12.2 CX34-43C 8813483EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48B EL180UH090E48B 8813484EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48B EL180UH090XE48B 8813485EL16XC1-042-230A TXV 40,000 14.5 12.2 CX34-44/48B EL296UH045XV36B 8813486EL16XC1-042-230A TXV 40,000 14.5 12.2 CX34-44/48B EL296UH070XV36B 8813487EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48B SL280UH090V36B 8813488EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48B SL280UH090V48B 8813489EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48B SL280UH090XV48B 8813490EL16XC1-042-230A TXV 40,000 14.5 12.2 CX34-44/48B SLP98UH070XV36B 8813491EL16XC1-042-230A TXV 40,500 15.5 13 CX34-44/48C EL180UH090E60C 8813492EL16XC1-042-230A TXV 40,500 15.5 13 CX34-44/48C EL180UH110E60C 8813493EL16XC1-042-230A TXV 40,500 15.5 13 CX34-44/48C EL180UH110XE60C 8813494NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 61: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 61

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48C EL195UH090XE48C 8813495EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-44/48C EL195UH110XE60C 8813496EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48C EL296UH090XE48C 8813497EL16XC1-042-230A TXV 40,500 15.1 12.5 CX34-44/48C EL296UH090XV36C 8813498EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48C EL296UH090XV48C 8813499EL16XC1-042-230A TXV 41,000 15.1 12.5 CX34-44/48C EL296UH090XV60C 8813500EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-44/48C EL296UH110XE60C 8813501EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48C EL296UH110XV48C 8813502EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48C EL296UH110XV60C 8813503EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-44/48C SL280UH090V60C 8813504EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-44/48C SL280UH090XV60C 8813505EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48C SL280UH110V60C 8813506EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48C SL280UH110XV60C 8813507EL16XC1-042-230A TXV 40,500 15.1 12.5 CX34-44/48C SLP98UH090XV36C 8813508EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48C SLP98UH090XV48C 8813509EL16XC1-042-230A TXV 41,000 15.1 12.5 CX34-44/48C SLP98UH090XV60C 8813510EL16XC1-042-230A TXV 40,500 15.5 12.5 CX34-44/48C SLP98UH110XV60C 8813511EL16XC1-042-230A TXV 42,000 16 13 CX34-49 EL180UH090E60C 8813512EL16XC1-042-230A TXV 42,000 16 13 CX34-49 EL180UH110E60C 8813513EL16XC1-042-230A TXV 42,000 16 13 CX34-49 EL180UH110XE60C 8813514EL16XC1-042-230A TXV 41,500 16 13 CX34-49 EL195UH090XE48C 8813515EL16XC1-042-230A TXV 42,000 16 13 CX34-49 EL195UH110XE60C 8813516EL16XC1-042-230A TXV 41,500 16 13 CX34-49 EL296UH090XE48C 8813517EL16XC1-042-230A TXV 41,500 16 13 CX34-49 EL296UH090XV36C 8813518EL16XC1-042-230A TXV 41,500 16 13 CX34-49 EL296UH090XV48C 8813519EL16XC1-042-230A TXV 42,000 16 13 CX34-49 EL296UH090XV60C 8813520EL16XC1-042-230A TXV 42,000 16 13 CX34-49 EL296UH110XE60C 8813521EL16XC1-042-230A TXV 42,000 16 13 CX34-49 EL296UH110XV48C 8813522EL16XC1-042-230A TXV 42,000 16 13 CX34-49 EL296UH110XV60C 8813523EL16XC1-042-230A TXV 42,000 16 13 CX34-49 SL280UH090V60C 8813524EL16XC1-042-230A TXV 42,000 16 13 CX34-49 SL280UH090XV60C 8813525EL16XC1-042-230A TXV 42,000 16 13 CX34-49 SL280UH110V60C 8813526EL16XC1-042-230A TXV 42,000 16 13 CX34-49 SL280UH110XV60C 8813527EL16XC1-042-230A TXV 41,500 16 13 CX34-49 SLP98UH090XV36C 8813528EL16XC1-042-230A TXV 41,500 16 13 CX34-49 SLP98UH090XV48C 8813529EL16XC1-042-230A TXV 42,000 16 13 CX34-49 SLP98UH090XV60C 8813530EL16XC1-042-230A TXV 42,000 16 13 CX34-49 SLP98UH110XV60C 8813531EL16XC1-042-230A TXV 41,500 14.5 12.5 CX34-49 8813532EL16XC1-042-230A TXV 41,000 16 13 CX34-50/60C EL180UH090E60C 8813533EL16XC1-042-230A TXV 41,000 16 13 CX34-50/60C EL180UH110E60C 8813534EL16XC1-042-230A TXV 41,000 16 13 CX34-50/60C EL180UH110XE60C 8813535EL16XC1-042-230A TXV 41,000 15.5 13 CX34-50/60C EL195UH090XE48C 8813536EL16XC1-042-230A TXV 41,500 15.5 12.5 CX34-50/60C EL195UH110XE60C 8813537EL16XC1-042-230A TXV 41,000 15.5 13 CX34-50/60C EL296UH090XE48C 8813538EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-50/60C EL296UH090XV36C 8813539EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-50/60C EL296UH090XV48C 8813540EL16XC1-042-230A TXV 41,500 15.5 12.5 CX34-50/60C EL296UH090XV60C 8813541EL16XC1-042-230A TXV 41,500 15.5 12.5 CX34-50/60C EL296UH110XE60C 8813542EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-50/60C EL296UH110XV48C 8813543NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 62: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 62

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-50/60C EL296UH110XV60C 8813544EL16XC1-042-230A TXV 41,500 15.5 13 CX34-50/60C SL280UH090V60C 8813545EL16XC1-042-230A TXV 41,500 15.5 13 CX34-50/60C SL280UH090XV60C 8813546EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-50/60C SL280UH110V60C 8813547EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-50/60C SL280UH110XV60C 8813548EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-50/60C SLP98UH090XV36C 8813549EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-50/60C SLP98UH090XV48C 8813550EL16XC1-042-230A TXV 41,500 15.5 12.5 CX34-50/60C SLP98UH090XV60C 8813551EL16XC1-042-230A TXV 41,000 15.5 12.5 CX34-50/60C SLP98UH110XV60C 8813552EL16XC1-042-230A TXV 40,500 14.5 12.2 CX34-50/60C 8813553EL16XC1-042-230A TXV 42,000 16 13 CX34-60D EL180UH135E60D 8813554EL16XC1-042-230A TXV 42,000 16 13 CX34-60D EL195UH135XE60D 8813555EL16XC1-042-230A TXV 42,000 16 13 CX34-60D EL296UH135XE60D 8813556EL16XC1-042-230A TXV 42,000 16 13 CX34-60D SL280UH135V60D 8813557EL16XC1-042-230A TXV 41,000 14.5 12.2 CX34-60D 8813558EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL180UH090E60C 8813559EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL180UH110E60C 8813560EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL180UH110XE60C 8813561EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL195UH090XE48C 8813562EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL195UH110XE60C 8813563EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL296UH090XE48C 8813564EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL296UH090XV36C 8813565EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL296UH090XV48C 8813566EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL296UH090XV60C 8813567EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL296UH110XE60C 8813568EL16XC1-042-230A TXV 42,000 16 13 CX34-62C EL296UH110XV60C 8813569EL16XC1-042-230A TXV 42,000 16 13 CX34-62C SL280UH090V60C 8813570EL16XC1-042-230A TXV 42,000 16 13 CX34-62C SL280UH090XV60C 8813571EL16XC1-042-230A TXV 42,000 16 13 CX34-62C SL280UH110V60C 8813572EL16XC1-042-230A TXV 42,000 16 13 CX34-62C SL280UH110XV60C 8813573EL16XC1-042-230A TXV 42,000 16 13 CX34-62C SLP98UH090XV36C 8813574EL16XC1-042-230A TXV 42,000 16 13 CX34-62C SLP98UH090XV48C 8813575EL16XC1-042-230A TXV 42,000 16 13 CX34-62C SLP98UH090XV60C 8813576EL16XC1-042-230A TXV 42,000 16 13 CX34-62C SLP98UH110XV60C 8813577EL16XC1-042-230A TXV 42,000 15.1 12.5 CX34-62C 8813578EL16XC1-042-230A TXV 42,000 16 13 CX34-62D EL180UH135E60D 8813579EL16XC1-042-230A TXV 42,000 16 13 CX34-62D EL195UH135XE60D 8813580EL16XC1-042-230A TXV 42,000 16 13 CX34-62D EL296UH135XE60D 8813581EL16XC1-042-230A TXV 42,000 16 13 CX34-62D SL280UH135V60D 8813582EL16XC1-042-230A TXV 41,500 14.5 12.5 CX34-62D 8813583EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36B EL180UH090E48B 8813584EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36B EL180UH090XE48B 8813585EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36B SL280UH090V36B 8813586EL16XC1-042-230A TXV 39,500 14.5 12.5 CX35-30/36B SL280UH090V48B 8813587EL16XC1-042-230A TXV 39,500 14.5 12.5 CX35-30/36B SL280UH090XV48B 8813588EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C EL180UH090E60C 8813589EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C EL180UH110E60C 8813590EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C EL180UH110XE60C 8813591EL16XC1-042-230A TXV 39,000 15.1 12.5 CX35-30/36C EL195UH090XE48C 8813592NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 63: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 63

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C EL195UH110XE60C 8813593EL16XC1-042-230A TXV 39,000 15.1 12.5 CX35-30/36C EL296UH090XE48C 8813594EL16XC1-042-230A TXV 39,000 14.5 12.2 CX35-30/36C EL296UH090XV36C 8813595EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C EL296UH090XV48C 8813596EL16XC1-042-230A TXV 39,500 14.5 12.5 CX35-30/36C EL296UH090XV60C 8813597EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C EL296UH110XE60C 8813598EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C EL296UH110XV60C 8813599EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C SL280UH090V60C 8813600EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C SL280UH090XV60C 8813601EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C SL280UH110V60C 8813602EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C SL280UH110XV60C 8813603EL16XC1-042-230A TXV 39,000 14.5 12.2 CX35-30/36C SLP98UH090XV36C 8813604EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C SLP98UH090XV48C 8813605EL16XC1-042-230A TXV 39,500 14.5 12.5 CX35-30/36C SLP98UH090XV60C 8813606EL16XC1-042-230A TXV 39,500 15.1 12.5 CX35-30/36C SLP98UH110XV60C 8813607EL16XC1-042-230A TXV 41,000 15.5 13 CX35-36B EL180UH090E48B 8813608EL16XC1-042-230A TXV 41,000 15.5 13 CX35-36B EL180UH090XE48B 8813609EL16XC1-042-230A TXV 41,000 15.1 12.5 CX35-36B EL296UH045XV36B 8813610EL16XC1-042-230A TXV 41,000 15.1 12.5 CX35-36B EL296UH070XV36B 8813611EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-36B SL280UH090V36B 8813612EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-36B SL280UH090V48B 8813613EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-36B SL280UH090XV48B 8813614EL16XC1-042-230A TXV 41,000 15.1 12.5 CX35-36B SLP98UH070XV36B 8813615EL16XC1-042-230A TXV 41,000 14.5 12.2 CX35-36B 8813616EL16XC1-042-230A TXV 41,500 16 13 CX35-48B EL180UH090E48B 8813617EL16XC1-042-230A TXV 41,500 16 13 CX35-48B EL180UH090XE48B 8813618EL16XC1-042-230A TXV 41,000 15.1 12.5 CX35-48B EL296UH045XV36B 8813619EL16XC1-042-230A TXV 41,000 15.1 12.5 CX35-48B EL296UH070XV36B 8813620EL16XC1-042-230A TXV 41,500 15.5 12.5 CX35-48B SL280UH090V36B 8813621EL16XC1-042-230A TXV 41,500 15.5 12.5 CX35-48B SL280UH090V48B 8813622EL16XC1-042-230A TXV 41,500 15.5 12.5 CX35-48B SL280UH090XV48B 8813623EL16XC1-042-230A TXV 41,000 15.1 12.5 CX35-48B SLP98UH070XV36B 8813624EL16XC1-042-230A TXV 41,000 14.5 12.2 CX35-48B 8813625EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL180UH090E60C 8813626EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL180UH110E60C 8813627EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL180UH110XE60C 8813628EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL195UH090XE48C 8813629EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL195UH110XE60C 8813630EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL296UH090XE48C 8813631EL16XC1-042-230A TXV 41,500 15.5 13 CX35-48C EL296UH090XV36C 8813632EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL296UH090XV48C 8813633EL16XC1-042-230A TXV 41,500 15.5 13 CX35-48C EL296UH090XV60C 8813634EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL296UH110XE60C 8813635EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL296UH110XV48C 8813636EL16XC1-042-230A TXV 41,500 16 13 CX35-48C EL296UH110XV60C 8813637EL16XC1-042-230A TXV 42,000 16 13 CX35-48C SL280UH090V60C 8813638EL16XC1-042-230A TXV 42,000 16 13 CX35-48C SL280UH090XV60C 8813639EL16XC1-042-230A TXV 41,500 16 13 CX35-48C SL280UH110V60C 8813640EL16XC1-042-230A TXV 41,500 16 13 CX35-48C SL280UH110XV60C 8813641NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 64: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 64

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 41,500 15.5 13 CX35-48C SLP98UH090XV36C 8813642EL16XC1-042-230A TXV 41,500 16 13 CX35-48C SLP98UH090XV48C 8813643EL16XC1-042-230A TXV 41,500 15.5 13 CX35-48C SLP98UH090XV60C 8813644EL16XC1-042-230A TXV 41,500 16 13 CX35-48C SLP98UH110XV60C 8813645EL16XC1-042-230A TXV 41,000 14.5 12.2 CX35-48C 8813646EL16XC1-042-230A TXV 42,000 16 13 CX35-49C EL180UH090E60C 8813647EL16XC1-042-230A TXV 42,000 16 13 CX35-49C EL180UH110E60C 8813648EL16XC1-042-230A TXV 42,000 16 13 CX35-49C EL180UH110XE60C 8813649EL16XC1-042-230A TXV 41,500 16 13 CX35-49C EL195UH090XE48C 8813650EL16XC1-042-230A TXV 42,000 16 13 CX35-49C EL195UH110XE60C 8813651EL16XC1-042-230A TXV 41,500 16 13 CX35-49C EL296UH090XE48C 8813652EL16XC1-042-230A TXV 41,500 16 13 CX35-49C EL296UH090XV36C 8813653EL16XC1-042-230A TXV 41,500 16 13 CX35-49C EL296UH090XV48C 8813654EL16XC1-042-230A TXV 42,000 16 13 CX35-49C EL296UH090XV60C 8813655EL16XC1-042-230A TXV 42,000 16 13 CX35-49C EL296UH110XE60C 8813656EL16XC1-042-230A TXV 42,000 16 13 CX35-49C EL296UH110XV48C 8813657EL16XC1-042-230A TXV 42,000 16 13 CX35-49C EL296UH110XV60C 8813658EL16XC1-042-230A TXV 42,000 16 13 CX35-49C SL280UH090V60C 8813659EL16XC1-042-230A TXV 42,000 16 13 CX35-49C SL280UH090XV60C 8813660EL16XC1-042-230A TXV 42,000 16 13 CX35-49C SL280UH110V60C 8813661EL16XC1-042-230A TXV 42,000 16 13 CX35-49C SL280UH110XV60C 8813662EL16XC1-042-230A TXV 41,500 16 13 CX35-49C SLP98UH090XV36C 8813663EL16XC1-042-230A TXV 41,500 16 13 CX35-49C SLP98UH090XV48C 8813664EL16XC1-042-230A TXV 42,000 16 13 CX35-49C SLP98UH090XV60C 8813665EL16XC1-042-230A TXV 42,000 16 13 CX35-49C SLP98UH110XV60C 8813666EL16XC1-042-230A TXV 41,500 14.5 12.5 CX35-49C 8813667EL16XC1-042-230A TXV 41,000 16 13 CX35-50/60C EL180UH090E60C 8813668EL16XC1-042-230A TXV 41,000 16 13 CX35-50/60C EL180UH110E60C 8813669EL16XC1-042-230A TXV 41,000 16 13 CX35-50/60C EL180UH110XE60C 8813670EL16XC1-042-230A TXV 41,000 15.5 13 CX35-50/60C EL195UH090XE48C 8813671EL16XC1-042-230A TXV 41,500 15.5 12.5 CX35-50/60C EL195UH110XE60C 8813672EL16XC1-042-230A TXV 41,000 15.5 13 CX35-50/60C EL296UH090XE48C 8813673EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-50/60C EL296UH090XV36C 8813674EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-50/60C EL296UH090XV48C 8813675EL16XC1-042-230A TXV 41,500 15.5 12.5 CX35-50/60C EL296UH090XV60C 8813676EL16XC1-042-230A TXV 41,500 15.5 12.5 CX35-50/60C EL296UH110XE60C 8813677EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-50/60C EL296UH110XV48C 8813678EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-50/60C EL296UH110XV60C 8813679EL16XC1-042-230A TXV 41,500 15.5 13 CX35-50/60C SL280UH090V60C 8813680EL16XC1-042-230A TXV 41,500 15.5 13 CX35-50/60C SL280UH090XV60C 8813681EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-50/60C SL280UH110V60C 8813682EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-50/60C SL280UH110XV60C 8813683EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-50/60C SLP98UH090XV36C 8813684EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-50/60C SLP98UH090XV48C 8813685EL16XC1-042-230A TXV 41,500 15.5 12.5 CX35-50/60C SLP98UH090XV60C 8813686EL16XC1-042-230A TXV 41,000 15.5 12.5 CX35-50/60C SLP98UH110XV60C 8813687EL16XC1-042-230A TXV 40,500 14.5 12.2 CX35-50/60C 8813688EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL180UH090E60C 8813689EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL180UH110E60C 8813690NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 65: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 65

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL180UH110XE60C 8813691EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL195UH090XE48C 8813692EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL195UH110XE60C 8813693EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL296UH090XE48C 8813694EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL296UH090XV36C 8813695EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL296UH090XV48C 8813696EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL296UH090XV60C 8813697EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL296UH110XE60C 8813698EL16XC1-042-230A TXV 42,000 16 13 CX35-60C EL296UH110XV60C 8813699EL16XC1-042-230A TXV 42,000 16 13 CX35-60C SL280UH090V60C 8813700EL16XC1-042-230A TXV 42,000 16 13 CX35-60C SL280UH090XV60C 8813701EL16XC1-042-230A TXV 42,000 16 13 CX35-60C SL280UH110V60C 8813702EL16XC1-042-230A TXV 42,000 16 13 CX35-60C SL280UH110XV60C 8813703EL16XC1-042-230A TXV 42,000 16 13 CX35-60C SLP98UH090XV36C 8813704EL16XC1-042-230A TXV 42,000 16 13 CX35-60C SLP98UH090XV48C 8813705EL16XC1-042-230A TXV 42,000 16 13 CX35-60C SLP98UH090XV60C 8813706EL16XC1-042-230A TXV 42,000 16 13 CX35-60C SLP98UH110XV60C 8813707EL16XC1-042-230A TXV 42,000 15.1 12.5 CX35-60C 8813708EL16XC1-042-230A TXV 42,000 16 13 CX35-60D EL180UH135E60D 8813709EL16XC1-042-230A TXV 42,000 16 13 CX35-60D EL195UH135XE60D 8813710EL16XC1-042-230A TXV 42,000 16 13 CX35-60D EL296UH135XE60D 8813711EL16XC1-042-230A TXV 42,000 16 13 CX35-60D SL280UH135V60D 8813712EL16XC1-042-230A TXV 41,500 14.5 12.5 CX35-60D 8813713EL16XC1-047-230A TXV 46,500 15.1 12.5 C33-43 EL180UH090E48B 8898522EL16XC1-047-230A TXV 46,500 15.1 12.5 C33-43 EL180UH090XE48B 8898523EL16XC1-047-230A TXV 46,000 14.5 12.2 C33-43C 9850166EL16XC1-047-230A TXV 45,500 14.5 12.2 C33-48 EL180UH090E48B 8898891EL16XC1-047-230A TXV 45,500 15.1 12.5 C33-48 EL180UH090E60C 8898524EL16XC1-047-230A TXV 45,500 14.5 12.2 C33-48 EL180UH090XE48B 8898892EL16XC1-047-230A TXV 45,500 14.5 12.5 C33-48 EL195UH090XE48C 8898525EL16XC1-047-230A TXV 45,500 15.1 12.5 C33-48 EL195UH110XE60C 8898526EL16XC1-047-230A TXV 45,500 14.5 12.5 C33-48 EL296UH090XE48C 8898527EL16XC1-047-230A TXV 45,500 15.1 12.5 C33-48 EL296UH110XE60C 8898528EL16XC1-047-230A TXV 45,500 15.1 12.5 C33-48 SL280UH090V60C 8898529EL16XC1-047-230A TXV 45,500 15.1 12.5 C33-48 SL280UH090XV60C 8898530EL16XC1-047-230A TXV 45,500 14.5 12.5 C33-48 SL280UH110V60C 8898531EL16XC1-047-230A TXV 45,500 14.5 12.5 C33-48 SL280UH110XV60C 8898532EL16XC1-047-230A TXV 45,500 14.25 12 C33-48 8898893EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 EL180UH090E60C 8898533EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 EL180UH110E60C 8898534EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 EL180UH110XE60C 8898535EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 EL195UH090XE48C 8898536EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 EL195UH110XE60C 8898537EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 EL296UH090XE48C 8898538EL16XC1-047-230A TXV 47,000 15.1 12.5 C33-49 EL296UH090XV48C 8898539EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 EL296UH090XV60C 8898540EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 EL296UH110XE60C 8898541EL16XC1-047-230A TXV 47,000 15.1 12.5 C33-49 EL296UH110XV60C 8898542EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 SL280UH090V60C 8898543NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 66: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 66

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 SL280UH110V60C 8898544EL16XC1-047-230A TXV 47,000 15.1 12.5 C33-49 SLP98UH090XV48C 8898545EL16XC1-047-230A TXV 47,000 15.5 12.5 C33-49 SLP98UH090XV60C 8898546EL16XC1-047-230A TXV 47,000 15.1 12.5 C33-49 SLP98UH110XV60C 8898547EL16XC1-047-230A TXV 47,000 14.5 12.2 C33-49C 9850174EL16XC1-047-230A TXV 46,000 15.1 12.5 C33-50/60C EL180UH090E60C 8898548EL16XC1-047-230A TXV 46,000 15.1 12.5 C33-50/60C EL180UH110E60C 8898549EL16XC1-047-230A TXV 46,000 15.1 12.5 C33-50/60C EL180UH110XE60C 8898550EL16XC1-047-230A TXV 46,000 15.1 12.5 C33-50/60C EL195UH090XE48C 8898551EL16XC1-047-230A TXV 46,000 15.1 12.5 C33-50/60C EL195UH110XE60C 8898552EL16XC1-047-230A TXV 46,000 15.1 12.5 C33-50/60C EL296UH090XE48C 8898553EL16XC1-047-230A TXV 46,000 15.1 12.5 C33-50/60C EL296UH110XE60C 8898554EL16XC1-047-230A TXV 46,000 14.5 12.2 C33-50/60C 9850167EL16XC1-047-230A TXV 47,500 15.5 12.5 C33-60D EL180UH135E60D 8898555EL16XC1-047-230A TXV 47,000 15.1 12.5 C33-60D EL195UH135XE60D 8898556EL16XC1-047-230A TXV 47,000 15.1 12.5 C33-60D EL296UH135XE60D 8898557EL16XC1-047-230A TXV 46,500 14.5 12.2 C33-60D 9850168EL16XC1-047-230A TXV 48,000 16 13 C33-62C EL180UH090E60C 8898558EL16XC1-047-230A TXV 47,500 16 13 C33-62C EL180UH110E60C 8898559EL16XC1-047-230A TXV 47,500 16 13 C33-62C EL180UH110XE60C 8898560EL16XC1-047-230A TXV 48,000 15.5 12.5 C33-62C EL195UH090XE48C 8898561EL16XC1-047-230A TXV 48,000 15.5 13 C33-62C EL195UH110XE60C 8898562EL16XC1-047-230A TXV 48,000 15.5 12.5 C33-62C EL296UH090XE48C 8898563EL16XC1-047-230A TXV 48,000 15.5 13 C33-62C EL296UH110XE60C 8898564EL16XC1-047-230A TXV 48,000 16 13 C33-62C SL280UH090V60C 8898565EL16XC1-047-230A TXV 48,000 16 13 C33-62C SL280UH090XV60C 8898566EL16XC1-047-230A TXV 48,000 16 13 C33-62C SL280UH110V60C 8898567EL16XC1-047-230A TXV 48,000 16 13 C33-62C SL280UH110XV60C 8898568EL16XC1-047-230A TXV 47,500 15.1 12.5 C33-62C 8898569EL16XC1-047-230A TXV 47,500 16 13 C33-62D EL180UH135E60D 8898570EL16XC1-047-230A TXV 47,500 15.5 12.5 C33-62D EL195UH135XE60D 8898571EL16XC1-047-230A TXV 47,500 15.5 12.5 C33-62D EL296UH135XE60D 8898572EL16XC1-047-230A TXV 47,000 14.5 12.2 C33-62D 9850169EL16XC1-047-230A TXV 46,500 15.1 12.5 C35-48B EL180UH090E48B 8898573EL16XC1-047-230A TXV 46,500 15.1 12.5 C35-48B EL180UH090XE48B 8898574EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C EL180UH090E60C 8898575EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C EL180UH110E60C 8898576EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C EL180UH110XE60C 8898577EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C EL195UH090XE48C 8898578EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C EL195UH110XE60C 8898579EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C EL296UH090XE48C 8898580EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C EL296UH090XV48C 8898581EL16XC1-047-230A TXV 47,500 15.5 12.5 C35-49C EL296UH090XV60C 8898582EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C EL296UH110XE60C 8898583EL16XC1-047-230A TXV 47,500 15.1 12.5 C35-49C EL296UH110XV60C 8898584EL16XC1-047-230A TXV 47,500 15.5 12.5 C35-49C SL280UH090V60C 8898585EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C SL280UH110V60C 8898586EL16XC1-047-230A TXV 47,000 15.5 12.5 C35-49C SLP98UH090XV48C 8898587EL16XC1-047-230A TXV 47,500 15.5 12.5 C35-49C SLP98UH090XV60C 8898588NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 67: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 67

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-047-230A TXV 47,500 15.1 12.5 C35-49C SLP98UH110XV60C 8898589EL16XC1-047-230A TXV 47,000 14.5 12.2 C35-49C 9850170EL16XC1-047-230A TXV 46,000 15.1 12.5 C35-50/60C EL180UH090E60C 8898590EL16XC1-047-230A TXV 46,000 15.1 12.5 C35-50/60C EL180UH110E60C 8898591EL16XC1-047-230A TXV 46,000 15.1 12.5 C35-50/60C EL180UH110XE60C 8898592EL16XC1-047-230A TXV 46,000 15.1 12.5 C35-50/60C EL195UH090XE48C 8898593EL16XC1-047-230A TXV 46,000 15.1 12.5 C35-50/60C EL195UH110XE60C 8898594EL16XC1-047-230A TXV 46,000 15.1 12.5 C35-50/60C EL296UH090XE48C 8898595EL16XC1-047-230A TXV 46,000 15.1 12.5 C35-50/60C EL296UH110XE60C 8898596EL16XC1-047-230A TXV 46,000 14.5 12.2 C35-50/60C 9850171EL16XC1-047-230A TXV 48,000 16 13 C35-60C EL180UH090E60C 8898597EL16XC1-047-230A TXV 48,000 16 13 C35-60C EL180UH110E60C 8898598EL16XC1-047-230A TXV 48,000 16 13 C35-60C EL180UH110XE60C 8898599EL16XC1-047-230A TXV 48,000 15.5 12.5 C35-60C EL195UH090XE48C 8898600EL16XC1-047-230A TXV 48,000 16 13 C35-60C EL195UH110XE60C 8898601EL16XC1-047-230A TXV 48,000 15.5 12.5 C35-60C EL296UH090XE48C 8898602EL16XC1-047-230A TXV 48,000 16 13 C35-60C EL296UH110XE60C 8898603EL16XC1-047-230A TXV 48,000 16 13 C35-60C SL280UH090V60C 8898604EL16XC1-047-230A TXV 48,000 16 13 C35-60C SL280UH090XV60C 8898605EL16XC1-047-230A TXV 48,000 16 13 C35-60C SL280UH110V60C 8898606EL16XC1-047-230A TXV 48,000 16 13 C35-60C SL280UH110XV60C 8898607EL16XC1-047-230A TXV 48,000 15.1 12.5 C35-60C 8898608EL16XC1-047-230A TXV 48,000 16 13 C35-60D EL180UH135E60D 8898609EL16XC1-047-230A TXV 47,500 15.5 12.5 C35-60D EL195UH135XE60D 8898610EL16XC1-047-230A TXV 47,500 15.5 12.5 C35-60D EL296UH135XE60D 8898611EL16XC1-047-230A TXV 47,000 14.5 12.2 C35-60D 9850172EL16XC1-047-230A TXV 47,000 16 13 CBA27UHE-048 10259481EL16XC1-047-230A TXV 47,000 15.1 12.5 CBX25UH-048 8898612EL16XC1-047-230A TXV 47,500 16 13 CBX25UHV-048 8898613EL16XC1-047-230A TXV 47,000 16 13 CBX27UH-048 8898614EL16XC1-047-230A TXV 46,500 16 13 CBX32MV-060 8898615EL16XC1-047-230A TXV 47,000 15.1 12.5 CBX40UHV-060 8898616EL16XC1-047-230A TXV 47,500 15.5 12.5 CH33-43 EL180UH090E48B 8898617EL16XC1-047-230A TXV 46,500 15.5 12.5 CH33-43 EL180UH090E60C 8898621EL16XC1-047-230A TXV 47,500 15.5 12.5 CH33-43 EL180UH090XE48B 8898618EL16XC1-047-230A TXV 46,500 15.5 12.5 CH33-43 EL180UH110E60C 8898622EL16XC1-047-230A TXV 46,500 15.5 12.5 CH33-43 EL180UH110XE60C 8898623EL16XC1-047-230A TXV 47,500 15.1 12.5 CH33-43 SL280UH090V48B 8898619EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-43 SL280UH090V60C 8898628EL16XC1-047-230A TXV 47,500 15.1 12.5 CH33-43 SL280UH090XV48B 8898620EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-43 SL280UH110V60C 8898629EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-43C EL195UH090XE48C 8898624EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-43C EL195UH110XE60C 8898625EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-43C EL296UH090XE48C 8898626EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-43C EL296UH110XE60C 8898627EL16XC1-047-230A TXV 46,500 14.5 12.2 CH33-43C 8898894EL16XC1-047-230A TXV 46,000 14.5 12.5 CH33-44/48 EL180UH090E48B 8898630EL16XC1-047-230A TXV 46,000 14.5 12.5 CH33-44/48 EL180UH090XE48B 8898631EL16XC1-047-230A TXV 46,000 14.5 12.2 CH33-44/48 SL280UH090V48B 8898895NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 68: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 68

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-047-230A TXV 46,000 14.5 12.2 CH33-44/48 SL280UH090XV48B 8898896EL16XC1-047-230A TXV 46,000 15.1 12.5 CH33-48C EL180UH090E60C 8898632EL16XC1-047-230A TXV 46,000 15.1 12.5 CH33-48C EL180UH110E60C 8898633EL16XC1-047-230A TXV 46,000 15.1 12.5 CH33-48C EL180UH110XE60C 8898634EL16XC1-047-230A TXV 46,000 15.1 12.5 CH33-48C EL195UH090XE48C 8898635EL16XC1-047-230A TXV 46,000 15.1 12.5 CH33-48C EL195UH110XE60C 8898636EL16XC1-047-230A TXV 46,000 15.1 12.5 CH33-48C EL296UH090XE48C 8898637EL16XC1-047-230A TXV 46,000 14.5 12.5 CH33-48C EL296UH090XV48C 8898638EL16XC1-047-230A TXV 46,500 14.5 12.5 CH33-48C EL296UH090XV60C 8898639EL16XC1-047-230A TXV 46,000 15.1 12.5 CH33-48C EL296UH110XE60C 8898640EL16XC1-047-230A TXV 46,500 14.5 12.5 CH33-48C EL296UH110XV60C 8898641EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-48C SL280UH090V60C 8898642EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-48C SL280UH090XV60C 8898643EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-48C SL280UH110V60C 8898644EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-48C SL280UH110XV60C 8898645EL16XC1-047-230A TXV 46,000 14.5 12.5 CH33-48C SLP98UH090XV48C 8898646EL16XC1-047-230A TXV 46,500 14.5 12.5 CH33-48C SLP98UH090XV60C 8898647EL16XC1-047-230A TXV 46,500 14.5 12.5 CH33-48C SLP98UH110XV60C 8898648EL16XC1-047-230A TXV 46,000 14.5 12.2 CH33-48C 8898897EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-49 EL180UH090E60C 8898649EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-49 EL180UH110E60C 8898650EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-49 EL180UH110XE60C 8898651EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-49 EL195UH090XE48C 8898652EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-49 EL195UH110XE60C 8898653EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-49 EL296UH090XE48C 8898654EL16XC1-047-230A TXV 47,000 15.1 12.5 CH33-49 EL296UH090XV48C 8898655EL16XC1-047-230A TXV 47,000 15.1 12.5 CH33-49 EL296UH090XV60C 8898656EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-49 EL296UH110XE60C 8898657EL16XC1-047-230A TXV 47,500 15.1 12.5 CH33-49 EL296UH110XV60C 8898658EL16XC1-047-230A TXV 47,000 15.1 12.5 CH33-49 SLP98UH090XV48C 8898659EL16XC1-047-230A TXV 47,000 15.1 12.5 CH33-49 SLP98UH090XV60C 8898660EL16XC1-047-230A TXV 47,500 15.1 12.5 CH33-49 SLP98UH110XV60C 8898661EL16XC1-047-230A TXV 47,000 14.5 12.2 CH33-49 9829641EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-50/60C EL180UH090E60C 8898662EL16XC1-047-230A TXV 46,500 15.5 12.5 CH33-50/60C EL180UH110E60C 8898663EL16XC1-047-230A TXV 46,500 15.5 12.5 CH33-50/60C EL180UH110XE60C 8898664EL16XC1-047-230A TXV 47,000 15.1 12.5 CH33-50/60C EL195UH090XE48C 8898665EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-50/60C EL195UH110XE60C 8898666EL16XC1-047-230A TXV 47,000 15.1 12.5 CH33-50/60C EL296UH090XE48C 8898667EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-50/60C EL296UH110XE60C 8898668EL16XC1-047-230A TXV 47,000 14.5 12.2 CH33-50/60C 8898898EL16XC1-047-230A TXV 47,000 15.5 12.5 CH33-60D EL180UH135E60D 8898669EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-60D EL195UH135XE60D 8898670EL16XC1-047-230A TXV 46,500 15.1 12.5 CH33-60D EL296UH135XE60D 8898671EL16XC1-047-230A TXV 47,500 15.5 12.5 CH33-62D EL180UH135E60D 8898672EL16XC1-047-230A TXV 47,000 15.1 12.5 CH33-62D EL195UH135XE60D 8898673EL16XC1-047-230A TXV 47,000 15.1 12.5 CH33-62D EL296UH135XE60D 8898674EL16XC1-047-230A TXV 47,500 15.5 12.5 CH35-42B EL180UH090E48B 8898675EL16XC1-047-230A TXV 47,500 15.1 12.5 CH35-42B SL280UH090XV48B 8898676NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 69: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 69

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-047-230A TXV 47,500 14.5 12.5 CH35-42B 8898677EL16XC1-047-230A TXV 47,000 15.5 12.5 CH35-42C EL180UH090E60C 8898678EL16XC1-047-230A TXV 46,500 15.5 12.5 CH35-42C EL180UH110E60C 8898679EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-42C EL195UH090XE48C 8898680EL16XC1-047-230A TXV 47,000 15.5 12.5 CH35-42C EL195UH110XE60C 8898681EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-42C EL296UH090XE48C 8898682EL16XC1-047-230A TXV 47,000 15.5 12.5 CH35-42C EL296UH110XE60C 8898683EL16XC1-047-230A TXV 47,000 15.5 12.5 CH35-42C SL280UH090V60C 8898684EL16XC1-047-230A TXV 47,000 15.1 12.5 CH35-42C SL280UH110V60C 8898685EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-42C SLP98UH090XV48C 8898686EL16XC1-047-230A TXV 47,000 15.1 12.5 CH35-42C SLP98UH090XV60C 8898687EL16XC1-047-230A TXV 47,000 15.1 12.5 CH35-42C SLP98UH110XV60C 8898688EL16XC1-047-230A TXV 46,500 14.5 12.2 CH35-42C 8898899EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48B EL180UH090E48B 8898689EL16XC1-047-230A TXV 46,500 14.5 12.2 CH35-48B SL280UH090V48B 8898900EL16XC1-047-230A TXV 46,500 14.5 12.2 CH35-48B 8898901EL16XC1-047-230A TXV 46,500 15.5 12.5 CH35-48C EL180UH090E60C 8898690EL16XC1-047-230A TXV 46,500 15.5 12.5 CH35-48C EL180UH110E60C 8898691EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C EL195UH090XE48C 8898692EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C EL195UH110XE60C 8898693EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C EL296UH090XE48C 8898694EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C EL296UH090XV48C 8898695EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C EL296UH090XV60C 8898696EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C EL296UH110XE60C 8898697EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C EL296UH110XV60C 8898698EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C SL280UH090V60C 8898699EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C SL280UH110V60C 8898700EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C SLP98UH090XV48C 8898701EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C SLP98UH090XV60C 8898702EL16XC1-047-230A TXV 46,500 15.1 12.5 CH35-48C SLP98UH110XV60C 8898703EL16XC1-047-230A TXV 46,500 14.5 12.2 CH35-48C 8898902EL16XC1-047-230A TXV 47,500 15.5 12.5 CH35-51C EL180UH090E60C 8898704EL16XC1-047-230A TXV 47,000 15.5 12.5 CH35-51C EL180UH110E60C 8898705EL16XC1-047-230A TXV 47,000 15.5 12.5 CH35-51C EL195UH090XE48C 8898706EL16XC1-047-230A TXV 47,500 15.5 12.5 CH35-51C EL195UH110XE60C 8898707EL16XC1-047-230A TXV 47,000 15.5 12.5 CH35-51C EL296UH090XE48C 8898708EL16XC1-047-230A TXV 47,500 15.1 12.5 CH35-51C EL296UH090XV48C 8898709EL16XC1-047-230A TXV 47,500 15.1 12.5 CH35-51C EL296UH090XV60C 8898710EL16XC1-047-230A TXV 47,500 15.5 12.5 CH35-51C EL296UH110XE60C 8898711EL16XC1-047-230A TXV 47,500 15.1 12.5 CH35-51C EL296UH110XV60C 8898712EL16XC1-047-230A TXV 47,500 15.5 12.5 CH35-51C SL280UH090V60C 8898713EL16XC1-047-230A TXV 47,500 15.5 12.5 CH35-51C SL280UH110V60C 8898714EL16XC1-047-230A TXV 47,500 15.1 12.5 CH35-51C SLP98UH090XV48C 8898715EL16XC1-047-230A TXV 47,500 15.1 12.5 CH35-51C SLP98UH090XV60C 8898716EL16XC1-047-230A TXV 47,500 15.1 12.5 CH35-51C SLP98UH110XV60C 8898717EL16XC1-047-230A TXV 47,000 14.5 12.2 CH35-51C 8898903EL16XC1-047-230A TXV 47,500 15.5 12.5 CH35-60D EL180UH135E60D 8898718EL16XC1-047-230A TXV 47,000 15.1 12.5 CH35-60D EL195UH135XE60D 8898719EL16XC1-047-230A TXV 47,000 15.1 12.5 CH35-60D EL296UH135XE60D 8898720NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 70: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 70

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-047-230A TXV 47,000 15.5 12.5 CH35-60D SL280UH135V60D 8898721EL16XC1-047-230A TXV 47,000 15.5 12.5 CH35-60D SLP98UH135XV60D 10040427EL16XC1-047-230A TXV 47,000 14.5 12.2 CH35-60D 8898904EL16XC1-047-230A TXV 46,500 15.5 12.5 CR33-50/60 EL180DF110E60C 8898723EL16XC1-047-230A TXV 46,000 15.1 12.5 CR33-50/60 EL195DF090XE48C 8898724EL16XC1-047-230A TXV 46,000 15.1 12.5 CR33-50/60 EL195DF110XE60C 8898725EL16XC1-047-230A TXV 46,000 15.1 12.5 CR33-50/60 EL296DF090XE48C 8898726EL16XC1-047-230A TXV 46,000 15.1 12.5 CR33-50/60 EL296DF110XE60C 8898727EL16XC1-047-230A TXV 46,500 15.5 12.5 CR33-50/60 SL280DF090V60C 8898728EL16XC1-047-230A TXV 46,500 15.5 12.5 CR33-50/60 SL280DF110V60C 8898729EL16XC1-047-230A TXV 46,000 14.5 12.2 CR33-50/60 10238961EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43 EL180UH090E48B 8898730EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43 EL180UH090XE48B 8898731EL16XC1-047-230A TXV 46,500 14.5 12.5 CX34-43 SL280UH090V48B 8898732EL16XC1-047-230A TXV 46,500 14.5 12.5 CX34-43 SL280UH090XV48B 8898733EL16XC1-047-230A TXV 46,500 15.5 12.5 CX34-43C EL180UH090E60C 8898734EL16XC1-047-230A TXV 46,000 15.5 12.5 CX34-43C EL180UH110E60C 8898735EL16XC1-047-230A TXV 46,000 15.5 12.5 CX34-43C EL180UH110XE60C 8898736EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C EL195UH090XE48C 8898737EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C EL195UH110XE60C 8898738EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C EL296UH090XE48C 8898739EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C EL296UH090XV48C 8898740EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C EL296UH090XV60C 8898741EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C EL296UH110XE60C 8898742EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C EL296UH110XV48C 8898743EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C EL296UH110XV60C 8898744EL16XC1-047-230A TXV 46,500 15.5 12.5 CX34-43C SL280UH090V60C 8898745EL16XC1-047-230A TXV 46,500 15.5 12.5 CX34-43C SL280UH090XV60C 8898746EL16XC1-047-230A TXV 46,500 15.5 12.5 CX34-43C SL280UH110V60C 8898905EL16XC1-047-230A TXV 46,500 15.5 12.5 CX34-43C SL280UH110XV60C 8898747EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C SLP98UH090XV48C 8898748EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C SLP98UH090XV60C 8898749EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-43C SLP98UH110XV60C 8898750EL16XC1-047-230A TXV 46,000 14.5 12.2 CX34-43C 8898906EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 EL180UH090E48B 8898909EL16XC1-047-230A TXV 45,500 15.1 12.5 CX34-44/48 EL180UH090E60C 8898751EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 EL180UH090XE48B 8898910EL16XC1-047-230A TXV 45,500 14.5 12.5 CX34-44/48 EL195UH090XE48C 8898752EL16XC1-047-230A TXV 45,500 15.1 12.5 CX34-44/48 EL195UH110XE60C 8898753EL16XC1-047-230A TXV 45,500 14.5 12.5 CX34-44/48 EL296UH090XE48C 8898754EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 EL296UH090XV48C 8898907EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 EL296UH090XV60C 8898911EL16XC1-047-230A TXV 45,500 15.1 12.5 CX34-44/48 EL296UH110XE60C 8898755EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 EL296UH110XV60C 8898916EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 SL280UH090V48B 8898914EL16XC1-047-230A TXV 45,500 15.1 12.5 CX34-44/48 SL280UH090V60C 8898756EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 SL280UH090XV48B 8898915EL16XC1-047-230A TXV 45,500 15.1 12.5 CX34-44/48 SL280UH090XV60C 8898757EL16XC1-047-230A TXV 45,500 14.5 12.5 CX34-44/48 SL280UH110V60C 8898758NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 71: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 71

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-047-230A TXV 45,500 14.5 12.5 CX34-44/48 SL280UH110XV60C 8898759EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 SLP98UH090XV48C 8898908EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 SLP98UH090XV60C 8898912EL16XC1-047-230A TXV 45,500 14.5 12.2 CX34-44/48 SLP98UH110XV60C 8898917EL16XC1-047-230A TXV 45,500 14.25 12 CX34-44/48 8898913EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 EL180UH090E60C 8898760EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 EL180UH110E60C 8898761EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 EL180UH110XE60C 8898762EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 EL195UH090XE48C 8898763EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 EL195UH110XE60C 8898764EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 EL296UH090XE48C 8898765EL16XC1-047-230A TXV 47,000 15.1 12.5 CX34-49 EL296UH090XV48C 8898766EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 EL296UH090XV60C 8898767EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 EL296UH110XE60C 8898768EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 EL296UH110XV48C 8898769EL16XC1-047-230A TXV 47,000 15.1 12.5 CX34-49 EL296UH110XV60C 8898770EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 SL280UH090V60C 8898771EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 SL280UH090XV60C 8898772EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 SL280UH110V60C 8898773EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 SL280UH110XV60C 8898774EL16XC1-047-230A TXV 47,000 15.1 12.5 CX34-49 SLP98UH090XV48C 8898775EL16XC1-047-230A TXV 47,000 15.5 12.5 CX34-49 SLP98UH090XV60C 8898776EL16XC1-047-230A TXV 47,000 15.1 12.5 CX34-49 SLP98UH110XV60C 8898777EL16XC1-047-230A TXV 47,000 14.5 12.2 CX34-49 8898918EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C EL180UH090E60C 8898778EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C EL180UH110E60C 8898779EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C EL180UH110XE60C 8898780EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C EL195UH090XE48C 8898781EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C EL195UH110XE60C 8898782EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C EL296UH090XE48C 8898783EL16XC1-047-230A TXV 46,000 14.5 12.5 CX34-50/60C EL296UH090XV48C 8898784EL16XC1-047-230A TXV 46,000 14.5 12.2 CX34-50/60C EL296UH090XV60C 8898919EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C EL296UH110XE60C 8898785EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C EL296UH110XV48C 8898786EL16XC1-047-230A TXV 46,500 14.5 12.5 CX34-50/60C EL296UH110XV60C 8898787EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-50/60C SL280UH090V60C 8898788EL16XC1-047-230A TXV 46,500 15.1 12.5 CX34-50/60C SL280UH090XV60C 8898789EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C SL280UH110V60C 8898790EL16XC1-047-230A TXV 46,000 15.1 12.5 CX34-50/60C SL280UH110XV60C 8898791EL16XC1-047-230A TXV 46,000 14.5 12.5 CX34-50/60C SLP98UH090XV48C 8898792EL16XC1-047-230A TXV 46,000 14.5 12.2 CX34-50/60C SLP98UH090XV60C 8898920EL16XC1-047-230A TXV 46,500 14.5 12.5 CX34-50/60C SLP98UH110XV60C 8898793EL16XC1-047-230A TXV 46,000 14.5 12.2 CX34-50/60C 8898921EL16XC1-047-230A TXV 47,500 15.5 12.5 CX34-60D EL180UH135E60D 8898794EL16XC1-047-230A TXV 47,000 15.1 12.5 CX34-60D EL195UH135XE60D 8898795EL16XC1-047-230A TXV 47,000 15.1 12.5 CX34-60D EL296UH135XE60D 8898796EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-60D EL296UH135XV60D 8898797EL16XC1-047-230A TXV 47,500 15.5 12.5 CX34-60D SL280UH135V60D 8898798EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-60D SLP98UH135XV60D 8898799NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 72: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 72

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-047-230A TXV 46,500 14.5 12.2 CX34-60D 8898922EL16XC1-047-230A TXV 48,000 16 13 CX34-62C EL180UH090E60C 8898800EL16XC1-047-230A TXV 47,500 16 13 CX34-62C EL180UH110E60C 8898801EL16XC1-047-230A TXV 47,500 16 13 CX34-62C EL180UH110XE60C 8898802EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-62C EL195UH090XE48C 8898803EL16XC1-047-230A TXV 48,000 15.5 13 CX34-62C EL195UH110XE60C 8898804EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-62C EL296UH090XE48C 8898805EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-62C EL296UH090XV48C 8898806EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-62C EL296UH090XV60C 8898807EL16XC1-047-230A TXV 48,000 15.5 13 CX34-62C EL296UH110XE60C 8898808EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-62C EL296UH110XV48C 8898809EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-62C EL296UH110XV60C 8898810EL16XC1-047-230A TXV 48,000 16 13 CX34-62C SL280UH090V60C 8898811EL16XC1-047-230A TXV 48,000 16 13 CX34-62C SL280UH090XV60C 8898812EL16XC1-047-230A TXV 48,000 16 13 CX34-62C SL280UH110V60C 8898813EL16XC1-047-230A TXV 48,000 16 13 CX34-62C SL280UH110XV60C 8898814EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-62C SLP98UH090XV48C 8898815EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-62C SLP98UH090XV60C 8898816EL16XC1-047-230A TXV 48,000 15.5 12.5 CX34-62C SLP98UH110XV60C 8898817EL16XC1-047-230A TXV 47,500 15.1 12.5 CX34-62C 8898818EL16XC1-047-230A TXV 47,500 16 13 CX34-62D EL180UH135E60D 8898819EL16XC1-047-230A TXV 47,500 15.5 12.5 CX34-62D EL195UH135XE60D 8898820EL16XC1-047-230A TXV 47,500 15.5 12.5 CX34-62D EL296UH135XE60D 8898821EL16XC1-047-230A TXV 47,500 15.5 12.5 CX34-62D EL296UH135XV60D 8898822EL16XC1-047-230A TXV 47,500 15.5 12.5 CX34-62D SL280UH135V60D 8898823EL16XC1-047-230A TXV 47,500 15.5 12.5 CX34-62D SLP98UH135XV60D 8898824EL16XC1-047-230A TXV 47,000 14.5 12.2 CX34-62D 8898923EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48B EL180UH090E48B 8898825EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48B EL180UH090XE48B 8898826EL16XC1-047-230A TXV 46,500 14.5 12.5 CX35-48B SL280UH090V48B 8898827EL16XC1-047-230A TXV 46,500 14.5 12.5 CX35-48B SL280UH090XV48B 8898828EL16XC1-047-230A TXV 46,500 15.5 12.5 CX35-48C EL180UH090E60C 8898829EL16XC1-047-230A TXV 47,000 14.5 12.5 CX35-48C EL180UH110E60C 8898830EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C EL195UH090XE48C 8898831EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C EL195UH110XE60C 8898832EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C EL296UH090XE48C 8898833EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C EL296UH090XV48C 8898834EL16XC1-047-230A TXV 46,500 14.5 12.5 CX35-48C EL296UH090XV60C 8898835EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C EL296UH110XE60C 8898836EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C EL296UH110XV60C 8898837EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C SL280UH090V60C 8898838EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C SL280UH110V60C 8898839EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C SLP98UH090XV48C 8898840EL16XC1-047-230A TXV 46,500 14.5 12.5 CX35-48C SLP98UH090XV60C 8898841EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-48C SLP98UH110XV60C 8898842EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C EL180UH090E60C 8898845EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C EL180UH110E60C 8898843EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C EL180UH110XE60C 8898844EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C EL195UH090XE48C 8898846NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 73: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 73

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C EL195UH110XE60C 8898847EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C EL296UH090XE48C 8898848EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C EL296UH090XV48C 8898849EL16XC1-047-230A TXV 47,500 15.5 12.5 CX35-49C EL296UH090XV60C 8898850EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C EL296UH110XE60C 8898851EL16XC1-047-230A TXV 47,500 15.1 12.5 CX35-49C EL296UH110XV60C 8898852EL16XC1-047-230A TXV 47,500 15.5 12.5 CX35-49C SL280UH090V60C 8898853EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C SL280UH110V60C 8898854EL16XC1-047-230A TXV 47,000 15.5 12.5 CX35-49C SLP98UH090XV48C 8898855EL16XC1-047-230A TXV 47,500 15.5 12.5 CX35-49C SLP98UH090XV60C 8898856EL16XC1-047-230A TXV 47,500 15.1 12.5 CX35-49C SLP98UH110XV60C 8898857EL16XC1-047-230A TXV 47,000 14.5 12.2 CX35-49C 8898924EL16XC1-047-230A TXV 46,000 15.1 12.5 CX35-50/60C EL180UH090E60C 8898858EL16XC1-047-230A TXV 46,000 15.1 12.5 CX35-50/60C EL180UH110E60C 8898859EL16XC1-047-230A TXV 46,000 15.1 12.5 CX35-50/60C EL180UH110XE60C 8898860EL16XC1-047-230A TXV 46,000 15.1 12.5 CX35-50/60C EL195UH090XE48C 8898861EL16XC1-047-230A TXV 46,000 15.1 12.5 CX35-50/60C EL195UH110XE60C 8898862EL16XC1-047-230A TXV 46,000 15.1 12.5 CX35-50/60C EL296UH090XE48C 8898863EL16XC1-047-230A TXV 46,000 15.1 12.5 CX35-50/60C EL296UH110XE60C 8898864EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-50/60C SL280UH090V60C 8898865EL16XC1-047-230A TXV 46,500 15.1 12.5 CX35-50/60C SL280UH090XV60C 8898866EL16XC1-047-230A TXV 46,000 15.1 12.5 CX35-50/60C SL280UH110V60C 8898867EL16XC1-047-230A TXV 46,000 15.1 12.5 CX35-50/60C SL280UH110XV60C 8898868EL16XC1-047-230A TXV 46,000 14.5 12.5 CX35-50/60C SLP98UH090XV48C 8898869EL16XC1-047-230A TXV 46,000 14.5 12.2 CX35-50/60C SLP98UH090XV60C 8898925EL16XC1-047-230A TXV 46,500 14.5 12.5 CX35-50/60C SLP98UH110XV60C 8898870EL16XC1-047-230A TXV 46,000 14.5 12.2 CX35-50/60C 8898926EL16XC1-047-230A TXV 48,000 16 13 CX35-60C EL180UH090E60C 8898871EL16XC1-047-230A TXV 48,000 16 13 CX35-60C EL180UH110E60C 8898872EL16XC1-047-230A TXV 48,000 16 13 CX35-60C EL180UH110XE60C 8898873EL16XC1-047-230A TXV 48,000 15.5 12.5 CX35-60C EL195UH090XE48C 8898874EL16XC1-047-230A TXV 48,000 16 13 CX35-60C EL195UH110XE60C 8898875EL16XC1-047-230A TXV 48,000 15.5 12.5 CX35-60C EL296UH090XE48C 8898876EL16XC1-047-230A TXV 48,000 16 13 CX35-60C EL296UH110XE60C 8898877EL16XC1-047-230A TXV 48,000 16 13 CX35-60C SL280UH090V60C 8898878EL16XC1-047-230A TXV 48,000 16 13 CX35-60C SL280UH090XV60C 8898879EL16XC1-047-230A TXV 48,000 16 13 CX35-60C SL280UH110V60C 8898880EL16XC1-047-230A TXV 48,000 16 13 CX35-60C SL280UH110XV60C 8898881EL16XC1-047-230A TXV 48,000 15.5 12.5 CX35-60C SLP98UH090XV48C 8898882EL16XC1-047-230A TXV 48,000 15.5 12.5 CX35-60C SLP98UH090XV60C 8898883EL16XC1-047-230A TXV 48,000 15.5 12.5 CX35-60C SLP98UH110XV60C 8898884EL16XC1-047-230A TXV 48,000 15.1 12.5 CX35-60C 8898885EL16XC1-047-230A TXV 48,000 16 13 CX35-60D EL180UH135E60D 8898886EL16XC1-047-230A TXV 47,500 15.5 12.5 CX35-60D EL195UH135XE60D 8898887EL16XC1-047-230A TXV 47,500 15.5 12.5 CX35-60D EL296UH135XE60D 8898888EL16XC1-047-230A TXV 48,000 15.5 12.5 CX35-60D EL296UH135XV60D 10304762EL16XC1-047-230A TXV 47,500 15.5 12.5 CX35-60D SL280UH135V60D 8898889EL16XC1-047-230A TXV 48,000 15.5 12.5 CX35-60D SLP98UH135XV60D 8898890EL16XC1-047-230A TXV 47,000 14.5 12.2 CX35-60D 8898927NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 74: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 74

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A RFC 47,000 14 12.2 C33-62C 8810985EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-43B EL180UH090E48B 8810887EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-43B EL180UH090XE48B 8810888EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C EL180UH090E60C 8810889EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C EL180UH110E60C 8810890EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C EL180UH110XE60C 8810891EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C EL195UH090XE48C 8810892EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C EL195UH110XE60C 8810893EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C EL296UH090XE48C 8810894EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-43C EL296UH090XV48C 8810895EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-43C EL296UH090XV60C 8810896EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C EL296UH110XE60C 8810897EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C EL296UH110XV48C 8810898EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-43C EL296UH110XV60C 8810899EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C SL280UH090V60C 8810900EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C SL280UH090XV60C 8810901EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C SL280UH110V60C 8810902EL16XC1-048-230A TXV 46,000 14.5 12.5 C33-43C SL280UH110XV60C 8810903EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-43C SLP98UH090XV48C 8810904EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-43C SLP98UH090XV60C 8810905EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-43C SLP98UH110XV60C 8810906EL16XC1-048-230A TXV 45,000 14 12 C33-48B EL180UH090E48B 8810907EL16XC1-048-230A TXV 45,000 14 12 C33-48B EL180UH090XE48B 8810908EL16XC1-048-230A TXV 45,000 14.5 12.2 C33-48C EL180UH090E60C 8810909EL16XC1-048-230A TXV 44,500 14.5 12.2 C33-48C EL180UH110E60C 8810910EL16XC1-048-230A TXV 44,500 14.5 12.2 C33-48C EL180UH110XE60C 8810911EL16XC1-048-230A TXV 45,000 14.25 12.2 C33-48C EL195UH090XE48C 8810912EL16XC1-048-230A TXV 45,000 14.25 12.2 C33-48C EL195UH110XE60C 8810913EL16XC1-048-230A TXV 45,000 14.25 12.2 C33-48C EL296UH090XE48C 8810914EL16XC1-048-230A TXV 45,000 14 12 C33-48C EL296UH090XV48C 8810915EL16XC1-048-230A TXV 45,000 14.25 12.2 C33-48C EL296UH110XE60C 8810916EL16XC1-048-230A TXV 45,000 14 12 C33-48C EL296UH110XV48C 8810917EL16XC1-048-230A TXV 45,000 14.25 12.2 C33-48C SL280UH090V60C 8810918EL16XC1-048-230A TXV 45,000 14.25 12.2 C33-48C SL280UH090XV60C 8810919EL16XC1-048-230A TXV 45,000 14.25 12.2 C33-48C SL280UH110V60C 8810920EL16XC1-048-230A TXV 45,000 14.25 12.2 C33-48C SL280UH110XV60C 8810921EL16XC1-048-230A TXV 45,000 14 12 C33-48C SLP98UH090XV48C 8810922EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-49 EL180UH090E60C 8810924EL16XC1-048-230A TXV 46,500 15.1 12.5 C33-49 EL180UH110E60C 8810925EL16XC1-048-230A TXV 46,500 15.1 12.5 C33-49 EL180UH110XE60C 8810926EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-49 EL195UH090XE48C 8810927EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-49 EL195UH110XE60C 8810928EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-49 EL296UH090XE48C 8810929EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-49 EL296UH090XV48C 8810930EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-49 EL296UH090XV60C 8810931EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-49 EL296UH110XE60C 8810932EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-49 EL296UH110XV48C 8810933EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-49 EL296UH110XV60C 8810934EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-49 SL280UH090V60C 8810935NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 75: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 75

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-49 SL280UH090XV60C 8810936EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-49 SL280UH110V60C 8810937EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-49 SL280UH110XV60C 8810938EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-49 SLP98UH090XV48C 8810939EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-49 SLP98UH090XV60C 8810940EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-49 SLP98UH110XV60C 8810941EL16XC1-048-230A TXV 46,500 14.25 12 C33-49 8810923EL16XC1-048-230A TXV 45,500 14.5 12.5 C33-50/60C EL180UH090E60C 8810942EL16XC1-048-230A TXV 45,000 14.5 12.5 C33-50/60C EL180UH110E60C 8810943EL16XC1-048-230A TXV 45,000 14.5 12.5 C33-50/60C EL180UH110XE60C 8810944EL16XC1-048-230A TXV 45,500 14.25 12.2 C33-50/60C EL195UH090XE48C 8810945EL16XC1-048-230A TXV 45,500 14.5 12.2 C33-50/60C EL195UH110XE60C 8810946EL16XC1-048-230A TXV 45,500 14.25 12.2 C33-50/60C EL296UH090XE48C 8810947EL16XC1-048-230A TXV 45,500 14.25 12.2 C33-50/60C EL296UH090XV48C 8810948EL16XC1-048-230A TXV 45,500 14.25 12 C33-50/60C EL296UH090XV60C 8810949EL16XC1-048-230A TXV 45,500 14.5 12.2 C33-50/60C EL296UH110XE60C 8810950EL16XC1-048-230A TXV 45,500 14.25 12.2 C33-50/60C EL296UH110XV48C 8810951EL16XC1-048-230A TXV 46,000 14.25 12.2 C33-50/60C EL296UH110XV60C 8810952EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-50/60C SL280UH090V60C 8810953EL16XC1-048-230A TXV 46,000 14.5 12.2 C33-50/60C SL280UH090XV60C 8810954EL16XC1-048-230A TXV 45,500 14.5 12.2 C33-50/60C SL280UH110V60C 8810955EL16XC1-048-230A TXV 45,500 14.5 12.2 C33-50/60C SL280UH110XV60C 8810956EL16XC1-048-230A TXV 45,500 14.25 12.2 C33-50/60C SLP98UH090XV48C 8810957EL16XC1-048-230A TXV 45,500 14.25 12 C33-50/60C SLP98UH090XV60C 8810958EL16XC1-048-230A TXV 46,000 14.25 12.2 C33-50/60C SLP98UH110XV60C 8810959EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-60D EL180UH135E60D 8810960EL16XC1-048-230A TXV 46,500 14.5 12.5 C33-60D EL195UH135XE60D 8810961EL16XC1-048-230A TXV 46,500 14.5 12.5 C33-60D EL296UH135XE60D 8810962EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-60D EL296UH135XV60D 8810963EL16XC1-048-230A TXV 47,000 15 12.5 C33-60D SL280UH135V60D 8810964EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-60D SLP98UH135XV60D 8810965EL16XC1-048-230A TXV 46,500 14 12 C33-60D 8810966EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C EL180UH090E60C 8810967EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-62C EL180UH110E60C 8810968EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-62C EL180UH110XE60C 8810969EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C EL195UH090XE48C 8810970EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C EL195UH110XE60C 8810971EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C EL296UH090XE48C 8810972EL16XC1-048-230A TXV 47,500 14.5 12.5 C33-62C EL296UH090XV48C 8810973EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C EL296UH090XV60C 8810974EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C EL296UH110XE60C 8810975EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C EL296UH110XV48C 8810976EL16XC1-048-230A TXV 47,500 14.5 12.5 C33-62C EL296UH110XV60C 8810977EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C SL280UH090V60C 8810978EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C SL280UH090XV60C 8810979EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C SL280UH110V60C 8810980EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C SL280UH110XV60C 8810981EL16XC1-048-230A TXV 47,500 14.5 12.5 C33-62C SLP98UH090XV48C 8810982EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62C SLP98UH090XV60C 8810983NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 76: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 76

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 47,500 14.5 12.5 C33-62C SLP98UH110XV60C 8810984EL16XC1-048-230A TXV 47,000 14.25 12.2 C33-62C 8810986EL16XC1-048-230A TXV 47,500 15.1 12.5 C33-62D EL180UH135E60D 8810987EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-62D EL195UH135XE60D 8810988EL16XC1-048-230A TXV 47,000 14.5 12.5 C33-62D EL296UH135XE60D 8810989EL16XC1-048-230A TXV 47,500 14.5 12.5 C33-62D EL296UH135XV60D 8810990EL16XC1-048-230A TXV 47,000 15.1 12.5 C33-62D SL280UH135V60D 8810991EL16XC1-048-230A TXV 47,500 14.5 12.5 C33-62D SLP98UH135XV60D 8810992EL16XC1-048-230A TXV 47,000 14.25 12.2 C33-62D 8810993EL16XC1-048-230A TXV 46,000 14.5 12.2 C35-48B EL180UH090E48B 8810994EL16XC1-048-230A TXV 46,000 14.5 12.2 C35-48B EL180UH090XE48B 8810995EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-48C EL180UH090E60C 8810996EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-48C EL180UH110E60C 8810997EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-48C EL180UH110XE60C 8810998EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-48C EL195UH090XE48C 8810999EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-48C EL195UH110XE60C 8811000EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-48C EL296UH090XE48C 8811001EL16XC1-048-230A TXV 46,500 14.5 12.2 C35-48C EL296UH090XV48C 8811002EL16XC1-048-230A TXV 46,500 14.5 12.5 C35-48C EL296UH090XV60C 8811003EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-48C EL296UH110XE60C 8811004EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-48C EL296UH110XV48C 8811005EL16XC1-048-230A TXV 46,500 14.5 12.5 C35-48C EL296UH110XV60C 8811006EL16XC1-048-230A TXV 46,500 14.5 12.5 C35-48C SL280UH090V60C 8811007EL16XC1-048-230A TXV 46,500 14.5 12.5 C35-48C SL280UH090XV60C 8811008EL16XC1-048-230A TXV 46,500 14.5 12.5 C35-48C SL280UH110V60C 8811009EL16XC1-048-230A TXV 46,500 14.5 12.5 C35-48C SL280UH110XV60C 8811010EL16XC1-048-230A TXV 46,500 14.5 12.2 C35-48C SLP98UH090XV48C 8811011EL16XC1-048-230A TXV 46,500 14.5 12.5 C35-48C SLP98UH090XV60C 8811012EL16XC1-048-230A TXV 46,500 14.5 12.5 C35-48C SLP98UH110XV60C 8811013EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-49C EL180UH090E60C 8811014EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-49C EL180UH110E60C 8811015EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-49C EL180UH110XE60C 8811016EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-49C EL195UH090XE48C 8811017EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-49C EL195UH110XE60C 8811018EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-49C EL296UH090XE48C 8811019EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-49C EL296UH090XV48C 8811020EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-49C EL296UH090XV60C 8811021EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-49C EL296UH110XE60C 8811022EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-49C EL296UH110XV48C 8811023EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-49C EL296UH110XV60C 8811024EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-49C SL280UH090V60C 8811025EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-49C SL280UH090XV60C 8811026EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-49C SL280UH110V60C 8811027EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-49C SL280UH110XV60C 8811028EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-49C SLP98UH090XV48C 8811029EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-49C SLP98UH090XV60C 8811030EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-49C SLP98UH110XV60C 8811031EL16XC1-048-230A TXV 47,000 14.25 12.2 C35-49C 8811032EL16XC1-048-230A TXV 45,500 14.5 12.5 C35-50/60C EL180UH090E60C 8811033NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 77: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 77

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 45,500 14.5 12.5 C35-50/60C EL180UH110E60C 8811034EL16XC1-048-230A TXV 45,500 14.5 12.5 C35-50/60C EL180UH110XE60C 8811035EL16XC1-048-230A TXV 45,500 14.5 12.2 C35-50/60C EL195UH090XE48C 8811036EL16XC1-048-230A TXV 45,500 14.5 12.2 C35-50/60C EL195UH110XE60C 8811037EL16XC1-048-230A TXV 45,500 14.5 12.2 C35-50/60C EL296UH090XE48C 8811038EL16XC1-048-230A TXV 46,000 14.25 12.2 C35-50/60C EL296UH090XV48C 8811039EL16XC1-048-230A TXV 46,000 14.25 12.2 C35-50/60C EL296UH090XV60C 8811040EL16XC1-048-230A TXV 45,500 14.5 12.2 C35-50/60C EL296UH110XE60C 8811041EL16XC1-048-230A TXV 46,000 14.25 12.2 C35-50/60C EL296UH110XV48C 8811042EL16XC1-048-230A TXV 46,000 14.25 12.2 C35-50/60C EL296UH110XV60C 8811043EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-50/60C SL280UH090V60C 8811044EL16XC1-048-230A TXV 46,000 14.5 12.5 C35-50/60C SL280UH090XV60C 8811045EL16XC1-048-230A TXV 46,000 14.5 12.2 C35-50/60C SL280UH110V60C 8811046EL16XC1-048-230A TXV 46,000 14.5 12.2 C35-50/60C SL280UH110XV60C 8811047EL16XC1-048-230A TXV 46,000 14.25 12.2 C35-50/60C SLP98UH090XV48C 8811048EL16XC1-048-230A TXV 46,000 14.25 12.2 C35-50/60C SLP98UH090XV60C 8811049EL16XC1-048-230A TXV 46,000 14.25 12.2 C35-50/60C SLP98UH110XV60C 8811050EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C EL180UH090E60C 8811051EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-60C EL180UH110E60C 8811052EL16XC1-048-230A TXV 47,000 15.1 12.5 C35-60C EL180UH110XE60C 8811053EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C EL195UH090XE48C 8811054EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C EL195UH110XE60C 8811055EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C EL296UH090XE48C 8811056EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C EL296UH090XV48C 8811057EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C EL296UH090XV60C 8811058EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C EL296UH110XE60C 8811059EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C EL296UH110XV48C 8811060EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C EL296UH110XV60C 8811061EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C SL280UH090V60C 8811062EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C SL280UH090XV60C 8811063EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C SL280UH110V60C 8811064EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C SL280UH110XV60C 8811065EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C SLP98UH090XV48C 8811066EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C SLP98UH090XV60C 8811067EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60C SLP98UH110XV60C 8811068EL16XC1-048-230A TXV 47,000 14.25 12.2 C35-60C 8811069EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60D EL180UH135E60D 8811070EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-60D EL195UH135XE60D 8811071EL16XC1-048-230A TXV 47,000 14.5 12.5 C35-60D EL296UH135XE60D 8811072EL16XC1-048-230A TXV 47,500 14.5 12.5 C35-60D EL296UH135XV60D 8811073EL16XC1-048-230A TXV 47,500 15.1 12.5 C35-60D SL280UH135V60D 8811074EL16XC1-048-230A TXV 47,500 14.5 12.5 C35-60D SLP98UH135XV60D 8811075EL16XC1-048-230A TXV 47,000 14.25 12.2 C35-60D 8811076EL16XC1-048-230A TXV 47,000 15 12.5 CBA27UHE-048 10259414EL16XC1-048-230A TXV 46,500 15.1 12.5 CBA27UHE-060 10259415EL16XC1-048-230A TXV 46,500 14.5 12.5 CBX25UH-048 8811077EL16XC1-048-230A TXV 47,000 14.5 12.5 CBX25UHV-048 8811078EL16XC1-048-230A TXV 46,000 14.5 12.5 CBX27UH-048 8811079EL16XC1-048-230A TXV 47,000 15.1 12.5 CBX27UH-060 8811080NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 78: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 78

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 46,000 14.5 12.2 CBX32M-048 8811081EL16XC1-048-230A TXV 46,500 14.25 12.2 CBX32M-060 8811082EL16XC1-048-230A TXV 46,000 14.5 12.2 CBX32MV-048 8811083EL16XC1-048-230A TXV 47,000 14.5 12.5 CBX32MV-060 8811084EL16XC1-048-230A TXV 46,000 14.5 12.2 CBX40UHV-048 8811085EL16XC1-048-230A TXV 46,500 14.5 12.2 CBX40UHV-060 8811086EL16XC1-048-230A TXV 44,500 14 12.2 CH23-51 EL180UH090E48B 8811736EL16XC1-048-230A TXV 43,500 14.5 12.2 CH23-51 EL180UH090E60B 10260330EL16XC1-048-230A TXV 44,000 14.25 12.2 CH23-51 EL180UH110E60C 8811087EL16XC1-048-230A TXV 44,000 14.25 12.2 CH23-51 EL180UH110XE60C 8811088EL16XC1-048-230A TXV 45,000 14.25 12.2 CH23-65 EL180UH090E48B 8811089EL16XC1-048-230A TXV 45,000 14.5 12.2 CH23-65 EL180UH090E60C 8811090EL16XC1-048-230A TXV 45,000 14.25 12.2 CH23-65 EL180UH090XE48B 8811091EL16XC1-048-230A TXV 45,000 14.5 12.5 CH23-65 EL180UH110E60C 8811092EL16XC1-048-230A TXV 45,000 14.5 12.5 CH23-65 EL180UH110XE60C 8811093EL16XC1-048-230A TXV 47,000 15.1 12.5 CH23-68 EL180UH135E60D 8811094EL16XC1-048-230A TXV 47,000 14.5 12.5 CH23-68 EL195UH135XE60D 8811095EL16XC1-048-230A TXV 47,000 14.5 12.5 CH23-68 EL296UH135XE60D 8811096EL16XC1-048-230A TXV 46,500 14 12 CH23-68 8811097EL16XC1-048-230A TXV 46,000 14.5 12.2 CH33-43B EL180UH090E48B 8811098EL16XC1-048-230A TXV 46,000 14.5 12.2 CH33-43B EL180UH090XE48B 8811099EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-43C EL180UH090E60C 8811100EL16XC1-048-230A TXV 45,500 14.5 12.5 CH33-43C EL180UH110E60C 8811101EL16XC1-048-230A TXV 45,500 14.5 12.5 CH33-43C EL180UH110XE60C 8811102EL16XC1-048-230A TXV 46,000 14.5 12.2 CH33-43C EL195UH090XE48C 8811103EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-43C EL195UH110XE60C 8811104EL16XC1-048-230A TXV 46,000 14.5 12.2 CH33-43C EL296UH090XE48C 8811105EL16XC1-048-230A TXV 46,000 14.25 12.2 CH33-43C EL296UH090XV48C 8811106EL16XC1-048-230A TXV 46,000 14.25 12.2 CH33-43C EL296UH090XV60C 8811107EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-43C EL296UH110XE60C 8811108EL16XC1-048-230A TXV 46,000 14.5 12.2 CH33-43C EL296UH110XV48C 8811109EL16XC1-048-230A TXV 46,500 14.25 12.2 CH33-43C EL296UH110XV60C 8811110EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-43C SL280UH090V60C 8811111EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-43C SL280UH090XV60C 8811112EL16XC1-048-230A TXV 46,000 14.5 12.2 CH33-43C SL280UH110V60C 8811113EL16XC1-048-230A TXV 46,000 14.5 12.2 CH33-43C SL280UH110XV60C 8811114EL16XC1-048-230A TXV 46,000 14.25 12.2 CH33-43C SLP98UH090XV48C 8811115EL16XC1-048-230A TXV 46,000 14.25 12.2 CH33-43C SLP98UH090XV60C 8811116EL16XC1-048-230A TXV 46,500 14.25 12.2 CH33-43C SLP98UH110XV60C 8811117EL16XC1-048-230A TXV 45,500 14.25 12.2 CH33-44/48B EL180UH090E48B 8811118EL16XC1-048-230A TXV 45,500 14.25 12.2 CH33-44/48B EL180UH090XE48B 8811119EL16XC1-048-230A TXV 45,500 14.5 12.5 CH33-48C EL180UH090E60C 8811120EL16XC1-048-230A TXV 45,500 14.5 12.5 CH33-48C EL180UH110E60C 8811121EL16XC1-048-230A TXV 45,500 14.5 12.5 CH33-48C EL180UH110XE60C 8811122EL16XC1-048-230A TXV 45,500 14.25 12.2 CH33-48C EL195UH090XE48C 8811123EL16XC1-048-230A TXV 45,500 14.5 12.2 CH33-48C EL195UH110XE60C 8811124EL16XC1-048-230A TXV 45,500 14.25 12.2 CH33-48C EL296UH090XE48C 8811125EL16XC1-048-230A TXV 45,500 14.25 12.2 CH33-48C EL296UH090XV48C 8811126EL16XC1-048-230A TXV 45,500 14.25 12 CH33-48C EL296UH090XV60C 8811127NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 79: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 79

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 45,500 14.5 12.2 CH33-48C EL296UH110XE60C 8811128EL16XC1-048-230A TXV 45,500 14.25 12.2 CH33-48C EL296UH110XV48C 8811129EL16XC1-048-230A TXV 46,000 14.25 12.2 CH33-48C EL296UH110XV60C 8811130EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-48C SL280UH090V60C 8811131EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-48C SL280UH090XV60C 8811132EL16XC1-048-230A TXV 45,500 14.5 12.2 CH33-48C SL280UH110V60C 8811133EL16XC1-048-230A TXV 45,500 14.5 12.2 CH33-48C SL280UH110XV60C 8811134EL16XC1-048-230A TXV 45,500 14.25 12.2 CH33-48C SLP98UH090XV48C 8811135EL16XC1-048-230A TXV 45,500 14.25 12 CH33-48C SLP98UH090XV60C 8811136EL16XC1-048-230A TXV 46,000 14.25 12.2 CH33-48C SLP98UH110XV60C 8811137EL16XC1-048-230A TXV 46,500 15.1 12.5 CH33-49 EL180UH090E60C 8811139EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-49 EL180UH110E60C 8811140EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-49 EL180UH110XE60C 8811141EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-49 EL195UH090XE48C 8811142EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-49 EL195UH110XE60C 8811143EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-49 EL296UH090XE48C 8811144EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-49 EL296UH090XV48C 8811145EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-49 EL296UH090XV60C 8811146EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-49 EL296UH110XE60C 8811147EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-49 EL296UH110XV48C 8811148EL16XC1-048-230A TXV 47,000 14.5 12.5 CH33-49 EL296UH110XV60C 8811149EL16XC1-048-230A TXV 47,000 14.5 12.5 CH33-49 SL280UH090V60C 8811150EL16XC1-048-230A TXV 47,000 14.5 12.5 CH33-49 SL280UH090XV60C 8811151EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-49 SL280UH110V60C 8811152EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-49 SL280UH110XV60C 8811153EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-49 SLP98UH090XV48C 8811154EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-49 SLP98UH090XV60C 8811155EL16XC1-048-230A TXV 47,000 14.5 12.5 CH33-49 SLP98UH110XV60C 8811156EL16XC1-048-230A TXV 46,500 14 12 CH33-49 8811138EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-50/60C EL180UH090E60C 8811157EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-50/60C EL180UH110E60C 8811158EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-50/60C EL180UH110XE60C 8811159EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-50/60C EL195UH090XE48C 8811160EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-50/60C EL195UH110XE60C 8811161EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-50/60C EL296UH090XE48C 8811162EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-50/60C EL296UH090XV48C 8811163EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-50/60C EL296UH090XV60C 8811164EL16XC1-048-230A TXV 46,000 14.5 12.5 CH33-50/60C EL296UH110XE60C 8811165EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-50/60C EL296UH110XV48C 8811166EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-50/60C EL296UH110XV60C 8811167EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-50/60C SL280UH090V60C 8811168EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-50/60C SL280UH090XV60C 8811169EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-50/60C SL280UH110V60C 8811170EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-50/60C SL280UH110XV60C 8811171EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-50/60C SLP98UH090XV48C 8811172EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-50/60C SLP98UH090XV60C 8811173EL16XC1-048-230A TXV 46,500 14.5 12.2 CH33-50/60C SLP98UH110XV60C 8811174EL16XC1-048-230A TXV 46,000 14 12 CH33-50/60C 8811175EL16XC1-048-230A TXV 46,500 15 12.5 CH33-60D EL180UH135E60D 8811176NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 80: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 80

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 46,000 14.5 12.2 CH33-60D EL195UH135XE60D 8811177EL16XC1-048-230A TXV 46,000 14.5 12.2 CH33-60D EL296UH135XE60D 8811178EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-60D EL296UH135XV60D 8811179EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-60D SL280UH135V60D 8811180EL16XC1-048-230A TXV 46,500 14.5 12.5 CH33-60D SLP98UH135XV60D 8811181EL16XC1-048-230A TXV 47,000 15.1 12.5 CH33-62D EL180UH135E60D 8811182EL16XC1-048-230A TXV 47,000 14.5 12.5 CH33-62D EL195UH135XE60D 8811183EL16XC1-048-230A TXV 47,000 14.5 12.5 CH33-62D EL296UH135XE60D 8811184EL16XC1-048-230A TXV 47,000 14.5 12.5 CH33-62D EL296UH135XV60D 8811185EL16XC1-048-230A TXV 47,000 15 12.5 CH33-62D SL280UH135V60D 8811186EL16XC1-048-230A TXV 47,000 14.5 12.5 CH33-62D SLP98UH135XV60D 8811187EL16XC1-048-230A TXV 46,500 14 12 CH33-62D 8811188EL16XC1-048-230A TXV 47,500 14.5 12.5 CH35-42B EL180UH090E48B 8811189EL16XC1-048-230A TXV 47,500 14.5 12.5 CH35-42B EL180UH090XE48B 8811190EL16XC1-048-230A TXV 46,000 14.5 12.5 CH35-42C EL180UH090E60C 8811191EL16XC1-048-230A TXV 45,500 14.5 12.5 CH35-42C EL180UH110E60C 8811192EL16XC1-048-230A TXV 45,500 14.5 12.5 CH35-42C EL180UH110XE60C 8811193EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-42C EL195UH090XE48C 8811194EL16XC1-048-230A TXV 46,000 14.5 12.5 CH35-42C EL195UH110XE60C 8811195EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-42C EL296UH090XE48C 8811196EL16XC1-048-230A TXV 46,500 14.25 12.2 CH35-42C EL296UH090XV48C 8811197EL16XC1-048-230A TXV 46,500 14.25 12.2 CH35-42C EL296UH090XV60C 8811198EL16XC1-048-230A TXV 46,000 14.5 12.5 CH35-42C EL296UH110XE60C 8811199EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-42C EL296UH110XV48C 8811200EL16XC1-048-230A TXV 46,500 14.5 12.2 CH35-42C EL296UH110XV60C 8811201EL16XC1-048-230A TXV 46,500 14.5 12.5 CH35-42C SL280UH090V60C 8811202EL16XC1-048-230A TXV 46,500 14.5 12.5 CH35-42C SL280UH090XV60C 8811203EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-42C SL280UH110V60C 8811204EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-42C SL280UH110XV60C 8811205EL16XC1-048-230A TXV 46,500 14.25 12.2 CH35-42C SLP98UH090XV48C 8811206EL16XC1-048-230A TXV 46,500 14.25 12.2 CH35-42C SLP98UH090XV60C 8811207EL16XC1-048-230A TXV 46,500 14.5 12.2 CH35-42C SLP98UH110XV60C 8811208EL16XC1-048-230A TXV 46,000 14.25 12.2 CH35-48B EL180UH090E48B 8811209EL16XC1-048-230A TXV 46,000 14.25 12.2 CH35-48B EL180UH090XE48B 8811210EL16XC1-048-230A TXV 46,000 14.5 12.5 CH35-48C EL180UH090E60C 8811211EL16XC1-048-230A TXV 45,500 14.5 12.5 CH35-48C EL180UH110E60C 8811212EL16XC1-048-230A TXV 45,500 14.5 12.5 CH35-48C EL180UH110XE60C 8811213EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-48C EL195UH090XE48C 8811214EL16XC1-048-230A TXV 46,000 14.5 12.5 CH35-48C EL195UH110XE60C 8811215EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-48C EL296UH090XE48C 8811216EL16XC1-048-230A TXV 46,000 14.25 12.2 CH35-48C EL296UH090XV48C 8811217EL16XC1-048-230A TXV 46,000 14.25 12.2 CH35-48C EL296UH090XV60C 8811218EL16XC1-048-230A TXV 46,000 14.5 12.5 CH35-48C EL296UH110XE60C 8811219EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-48C EL296UH110XV48C 8811220EL16XC1-048-230A TXV 46,000 14.25 12.2 CH35-48C EL296UH110XV60C 8811221EL16XC1-048-230A TXV 46,000 14.5 12.5 CH35-48C SL280UH090V60C 8811222EL16XC1-048-230A TXV 46,000 14.5 12.5 CH35-48C SL280UH090XV60C 8811223EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-48C SL280UH110V60C 8811224EL16XC1-048-230A TXV 46,000 14.5 12.2 CH35-48C SL280UH110XV60C 8811225NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 81: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 81

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 46,000 14.25 12.2 CH35-48C SLP98UH090XV48C 8811226EL16XC1-048-230A TXV 46,000 14.25 12.2 CH35-48C SLP98UH090XV60C 8811227EL16XC1-048-230A TXV 46,000 14.25 12.2 CH35-48C SLP98UH110XV60C 8811228EL16XC1-048-230A TXV 46,500 15.1 12.5 CH35-51C EL180UH090E60C 8811229EL16XC1-048-230A TXV 46,500 15.1 12.5 CH35-51C EL180UH110E60C 8811230EL16XC1-048-230A TXV 46,500 15.1 12.5 CH35-51C EL180UH110XE60C 8811231EL16XC1-048-230A TXV 46,500 14.5 12.5 CH35-51C EL195UH090XE48C 8811232EL16XC1-048-230A TXV 46,500 14.5 12.5 CH35-51C EL195UH110XE60C 8811233EL16XC1-048-230A TXV 46,500 14.5 12.5 CH35-51C EL296UH090XE48C 8811234EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C EL296UH090XV48C 8811235EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C EL296UH090XV60C 8811236EL16XC1-048-230A TXV 46,500 14.5 12.5 CH35-51C EL296UH110XE60C 8811237EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C EL296UH110XV48C 8811238EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C EL296UH110XV60C 8811239EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C SL280UH090V60C 8811240EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C SL280UH090XV60C 8811241EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C SL280UH110V60C 8811242EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C SL280UH110XV60C 8811243EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C SLP98UH090XV48C 8811244EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C SLP98UH090XV60C 8811245EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-51C SLP98UH110XV60C 8811246EL16XC1-048-230A TXV 46,500 14.25 12 CH35-51C 8811247EL16XC1-048-230A TXV 47,000 15.1 12.5 CH35-60D EL180UH135E60D 8811248EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-60D EL195UH135XE60D 8811249EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-60D EL296UH135XE60D 8811250EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-60D EL296UH135XV60D 8811251EL16XC1-048-230A TXV 47,000 15 12.5 CH35-60D SL280UH135V60D 8811252EL16XC1-048-230A TXV 47,000 14.5 12.5 CH35-60D SLP98UH135XV60D 8811253EL16XC1-048-230A TXV 46,500 14 12 CH35-60D 8811254EL16XC1-048-230A TXV 45,000 14.5 12.5 CR33-48 EL180DF110E60C 8811255EL16XC1-048-230A TXV 44,500 14.25 12.2 CR33-48 EL195DF110XE60C 8811256EL16XC1-048-230A TXV 44,500 14.25 12.2 CR33-48 EL296DF110XE60C 8811257EL16XC1-048-230A TXV 45,000 14.25 12.2 CR33-48 SL280DF090V60C 8811258EL16XC1-048-230A TXV 45,000 14.25 12.2 CR33-48 SL280DF110V60C 8811259EL16XC1-048-230A TXV 45,500 14.5 12.5 CR33-50/60 EL180DF110E60C 8811260EL16XC1-048-230A TXV 45,500 14.5 12.5 CR33-50/60 EL195DF110XE60C 8811261EL16XC1-048-230A TXV 45,000 14 12 CR33-50/60 EL296DF090XV60C 8811262EL16XC1-048-230A TXV 45,500 14.5 12.5 CR33-50/60 EL296DF110XE60C 8811263EL16XC1-048-230A TXV 45,000 14.25 12 CR33-50/60 EL296DF110XV60C 8811264EL16XC1-048-230A TXV 45,500 14.5 12.5 CR33-50/60 SL280DF090V60C 8811265EL16XC1-048-230A TXV 45,500 14.5 12.5 CR33-50/60 SL280DF110V60C 8811266EL16XC1-048-230A TXV 45,000 14 12 CR33-50/60 SLP98DF090XV48C 8811267EL16XC1-048-230A TXV 45,000 14 12 CR33-50/60 SLP98DF090XV60C 8811268EL16XC1-048-230A TXV 45,000 14.25 12 CR33-50/60 SLP98DF110XV60C 8811269EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-43B EL180UH090E48B 8811270EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-43B EL180UH090XE48B 8811271EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C EL180UH090E60C 8811272EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C EL180UH110E60C 8811273EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C EL180UH110XE60C 8811274NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 82: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 82

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C EL195UH090XE48C 8811275EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C EL195UH110XE60C 8811276EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C EL296UH090XE48C 8811277EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-43C EL296UH090XV48C 8811278EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-43C EL296UH090XV60C 8811279EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C EL296UH110XE60C 8811280EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C EL296UH110XV48C 8811281EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-43C EL296UH110XV60C 8811282EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C SL280UH090V60C 8811283EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C SL280UH090XV60C 8811284EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C SL280UH110V60C 8811285EL16XC1-048-230A TXV 46,000 14.5 12.5 CX34-43C SL280UH110XV60C 8811286EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-43C SLP98UH090XV48C 8811287EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-43C SLP98UH090XV60C 8811288EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-43C SLP98UH110XV60C 8811289EL16XC1-048-230A TXV 45,000 14 12 CX34-44/48B EL180UH090E48B 8811290EL16XC1-048-230A TXV 45,000 14 12 CX34-44/48B EL180UH090XE48B 8811291EL16XC1-048-230A TXV 45,000 14.5 12.2 CX34-44/48C EL180UH090E60C 8811292EL16XC1-048-230A TXV 45,000 14.5 12.2 CX34-44/48C EL180UH110E60C 8811293EL16XC1-048-230A TXV 45,000 14.5 12.2 CX34-44/48C EL180UH110XE60C 8811294EL16XC1-048-230A TXV 45,000 14.25 12.2 CX34-44/48C EL195UH090XE48C 8811295EL16XC1-048-230A TXV 45,000 14.25 12.2 CX34-44/48C EL195UH110XE60C 8811296EL16XC1-048-230A TXV 45,000 14.25 12.2 CX34-44/48C EL296UH090XE48C 8811297EL16XC1-048-230A TXV 45,000 14 12 CX34-44/48C EL296UH090XV48C 8811298EL16XC1-048-230A TXV 45,000 14.25 12.2 CX34-44/48C EL296UH110XE60C 8811299EL16XC1-048-230A TXV 45,000 14 12 CX34-44/48C EL296UH110XV48C 8811300EL16XC1-048-230A TXV 45,000 14.25 12.2 CX34-44/48C SL280UH090V60C 8811301EL16XC1-048-230A TXV 45,000 14.25 12.2 CX34-44/48C SL280UH090XV60C 8811302EL16XC1-048-230A TXV 45,000 14.25 12.2 CX34-44/48C SL280UH110V60C 8811303EL16XC1-048-230A TXV 45,000 14.25 12.2 CX34-44/48C SL280UH110XV60C 8811304EL16XC1-048-230A TXV 45,000 14 12 CX34-44/48C SLP98UH090XV48C 8811305EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-49 EL180UH090E60C 8811307EL16XC1-048-230A TXV 46,500 15.1 12.5 CX34-49 EL180UH110E60C 8811308EL16XC1-048-230A TXV 46,500 15.1 12.5 CX34-49 EL180UH110XE60C 8811309EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-49 EL195UH090XE48C 8811310EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-49 EL195UH110XE60C 8811311EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-49 EL296UH090XE48C 8811312EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-49 EL296UH090XV48C 8811313EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-49 EL296UH090XV60C 8811314EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-49 EL296UH110XE60C 8811315EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-49 EL296UH110XV48C 8811316EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-49 EL296UH110XV60C 8811317EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-49 SL280UH090V60C 8811318EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-49 SL280UH090XV60C 8811319EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-49 SL280UH110V60C 8811320EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-49 SL280UH110XV60C 8811321EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-49 SLP98UH090XV48C 8811322EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-49 SLP98UH090XV60C 8811323EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-49 SLP98UH110XV60C 8811324NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 83: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 83

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 46,500 14.25 12 CX34-49 8811306EL16XC1-048-230A TXV 45,500 14.5 12.5 CX34-50/60C EL180UH090E60C 8811325EL16XC1-048-230A TXV 45,500 14.5 12.5 CX34-50/60C EL180UH110E60C 8811326EL16XC1-048-230A TXV 45,500 14.5 12.5 CX34-50/60C EL180UH110XE60C 8811327EL16XC1-048-230A TXV 45,500 14.25 12.2 CX34-50/60C EL195UH090XE48C 8811328EL16XC1-048-230A TXV 45,500 14.5 12.2 CX34-50/60C EL195UH110XE60C 8811329EL16XC1-048-230A TXV 45,500 14.25 12.2 CX34-50/60C EL296UH090XE48C 8811330EL16XC1-048-230A TXV 45,500 14.25 12.2 CX34-50/60C EL296UH090XV48C 8811331EL16XC1-048-230A TXV 45,500 14.25 12 CX34-50/60C EL296UH090XV60C 8811332EL16XC1-048-230A TXV 45,500 14.5 12.2 CX34-50/60C EL296UH110XE60C 8811333EL16XC1-048-230A TXV 45,500 14.25 12.2 CX34-50/60C EL296UH110XV48C 8811334EL16XC1-048-230A TXV 46,000 14.25 12.2 CX34-50/60C EL296UH110XV60C 8811335EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-50/60C SL280UH090V60C 8811336EL16XC1-048-230A TXV 46,000 14.5 12.2 CX34-50/60C SL280UH090XV60C 8811337EL16XC1-048-230A TXV 45,500 14.5 12.2 CX34-50/60C SL280UH110V60C 8811338EL16XC1-048-230A TXV 45,500 14.5 12.2 CX34-50/60C SL280UH110XV60C 8811339EL16XC1-048-230A TXV 45,500 14.25 12.2 CX34-50/60C SLP98UH090XV48C 8811340EL16XC1-048-230A TXV 45,500 14.25 12 CX34-50/60C SLP98UH090XV60C 8811341EL16XC1-048-230A TXV 46,000 14.25 12.2 CX34-50/60C SLP98UH110XV60C 8811342EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-60D EL180UH135E60D 8811343EL16XC1-048-230A TXV 46,500 14.5 12.5 CX34-60D EL195UH135XE60D 8811344EL16XC1-048-230A TXV 46,500 14.5 12.5 CX34-60D EL296UH135XE60D 8811345EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-60D EL296UH135XV60D 8811346EL16XC1-048-230A TXV 47,000 15 12.5 CX34-60D SL280UH135V60D 8811347EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-60D SLP98UH135XV60D 8811348EL16XC1-048-230A TXV 46,500 14 12 CX34-60D 8811349EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C EL180UH090E60C 8811351EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-62C EL180UH110E60C 8811352EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-62C EL180UH110XE60C 8811353EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C EL195UH090XE48C 8811354EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C EL195UH110XE60C 8811355EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C EL296UH090XE48C 8811356EL16XC1-048-230A TXV 47,500 14.5 12.5 CX34-62C EL296UH090XV48C 8811357EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C EL296UH090XV60C 8811358EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C EL296UH110XE60C 8811359EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C EL296UH110XV48C 8811360EL16XC1-048-230A TXV 47,500 14.5 12.5 CX34-62C EL296UH110XV60C 8811361EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C SL280UH090V60C 8811362EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C SL280UH090XV60C 8811363EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C SL280UH110V60C 8811364EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C SL280UH110XV60C 8811365EL16XC1-048-230A TXV 47,500 14.5 12.5 CX34-62C SLP98UH090XV48C 8811366EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62C SLP98UH090XV60C 8811367EL16XC1-048-230A TXV 47,500 14.5 12.5 CX34-62C SLP98UH110XV60C 8811368EL16XC1-048-230A TXV 47,000 14.25 12.2 CX34-62C 8811350EL16XC1-048-230A TXV 47,500 15.1 12.5 CX34-62D EL180UH135E60D 8811369EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-62D EL195UH135XE60D 8811370EL16XC1-048-230A TXV 47,000 14.5 12.5 CX34-62D EL296UH135XE60D 8811371EL16XC1-048-230A TXV 47,500 14.5 12.5 CX34-62D EL296UH135XV60D 8811372NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 84: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 84

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 47,000 15.1 12.5 CX34-62D SL280UH135V60D 8811373EL16XC1-048-230A TXV 47,500 14.5 12.5 CX34-62D SLP98UH135XV60D 8811374EL16XC1-048-230A TXV 47,000 14.25 12.2 CX34-62D 8811375EL16XC1-048-230A TXV 46,000 14.5 12.2 CX35-48B EL180UH090E48B 8811376EL16XC1-048-230A TXV 46,000 14.5 12.2 CX35-48B EL180UH090XE48B 8811377EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-48C EL180UH090E60C 8811378EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-48C EL180UH110E60C 8811379EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-48C EL180UH110XE60C 8811380EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-48C EL195UH090XE48C 8811381EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-48C EL195UH110XE60C 8811382EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-48C EL296UH090XE48C 8811383EL16XC1-048-230A TXV 46,500 14.5 12.2 CX35-48C EL296UH090XV48C 8811384EL16XC1-048-230A TXV 46,500 14.5 12.5 CX35-48C EL296UH090XV60C 8811385EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-48C EL296UH110XE60C 8811386EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-48C EL296UH110XV48C 8811387EL16XC1-048-230A TXV 46,500 14.5 12.5 CX35-48C EL296UH110XV60C 8811388EL16XC1-048-230A TXV 46,500 14.5 12.5 CX35-48C SL280UH090V60C 8811389EL16XC1-048-230A TXV 46,500 14.5 12.5 CX35-48C SL280UH090XV60C 8811390EL16XC1-048-230A TXV 46,500 14.5 12.5 CX35-48C SL280UH110V60C 8811391EL16XC1-048-230A TXV 46,500 14.5 12.5 CX35-48C SL280UH110XV60C 8811392EL16XC1-048-230A TXV 46,500 14.5 12.2 CX35-48C SLP98UH090XV48C 8811393EL16XC1-048-230A TXV 46,500 14.5 12.5 CX35-48C SLP98UH090XV60C 8811394EL16XC1-048-230A TXV 46,500 14.5 12.5 CX35-48C SLP98UH110XV60C 8811395EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-49C EL180UH090E60C 8811396EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-49C EL180UH110E60C 8811397EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-49C EL180UH110XE60C 8811398EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-49C EL195UH090XE48C 8811399EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-49C EL195UH110XE60C 8811400EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-49C EL296UH090XE48C 8811401EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-49C EL296UH090XV48C 8811402EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-49C EL296UH090XV60C 8811403EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-49C EL296UH110XE60C 8811404EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-49C EL296UH110XV48C 8811405EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-49C EL296UH110XV60C 8811406EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-49C SL280UH090V60C 8811407EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-49C SL280UH090XV60C 8811408EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-49C SL280UH110V60C 8811409EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-49C SL280UH110XV60C 8811410EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-49C SLP98UH090XV48C 8811411EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-49C SLP98UH090XV60C 8811412EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-49C SLP98UH110XV60C 8811413EL16XC1-048-230A TXV 47,000 14.25 12.2 CX35-49C 8811414EL16XC1-048-230A TXV 45,500 14.5 12.5 CX35-50/60C EL180UH090E60C 8811415EL16XC1-048-230A TXV 45,500 14.5 12.5 CX35-50/60C EL180UH110E60C 8811416EL16XC1-048-230A TXV 45,500 14.5 12.5 CX35-50/60C EL180UH110XE60C 8811417EL16XC1-048-230A TXV 45,500 14.5 12.2 CX35-50/60C EL195UH090XE48C 8811418EL16XC1-048-230A TXV 45,500 14.5 12.2 CX35-50/60C EL195UH110XE60C 8811419EL16XC1-048-230A TXV 45,500 14.5 12.2 CX35-50/60C EL296UH090XE48C 8811420EL16XC1-048-230A TXV 46,000 14.25 12.2 CX35-50/60C EL296UH090XV48C 8811421NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 85: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 85

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-048-230A TXV 46,000 14.25 12.2 CX35-50/60C EL296UH090XV60C 8811422EL16XC1-048-230A TXV 45,500 14.5 12.2 CX35-50/60C EL296UH110XE60C 8811423EL16XC1-048-230A TXV 46,000 14.25 12.2 CX35-50/60C EL296UH110XV48C 8811424EL16XC1-048-230A TXV 46,000 14.25 12.2 CX35-50/60C EL296UH110XV60C 8811425EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-50/60C SL280UH090V60C 8811426EL16XC1-048-230A TXV 46,000 14.5 12.5 CX35-50/60C SL280UH090XV60C 8811427EL16XC1-048-230A TXV 46,000 14.5 12.2 CX35-50/60C SL280UH110V60C 8811428EL16XC1-048-230A TXV 46,000 14.5 12.2 CX35-50/60C SL280UH110XV60C 8811429EL16XC1-048-230A TXV 46,000 14.25 12.2 CX35-50/60C SLP98UH090XV48C 8811430EL16XC1-048-230A TXV 46,000 14.25 12.2 CX35-50/60C SLP98UH090XV60C 8811431EL16XC1-048-230A TXV 46,000 14.25 12.2 CX35-50/60C SLP98UH110XV60C 8811432EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C EL180UH090E60C 8811433EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-60C EL180UH110E60C 8811434EL16XC1-048-230A TXV 47,000 15.1 12.5 CX35-60C EL180UH110XE60C 8811435EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C EL195UH090XE48C 8811436EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C EL195UH110XE60C 8811437EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C EL296UH090XE48C 8811438EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C EL296UH090XV48C 8811439EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C EL296UH090XV60C 8811440EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C EL296UH110XE60C 8811441EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C EL296UH110XV48C 8811442EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C EL296UH110XV60C 8811443EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C SL280UH090V60C 8811444EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C SL280UH090XV60C 8811445EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C SL280UH110V60C 8811446EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C SL280UH110XV60C 8811447EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C SLP98UH090XV48C 8811448EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C SLP98UH090XV60C 8811449EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60C SLP98UH110XV60C 8811450EL16XC1-048-230A TXV 47,000 14.25 12.2 CX35-60C 8811451EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60D EL180UH135E60D 8811452EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-60D EL195UH135XE60D 8811453EL16XC1-048-230A TXV 47,000 14.5 12.5 CX35-60D EL296UH135XE60D 8811454EL16XC1-048-230A TXV 47,500 14.5 12.5 CX35-60D EL296UH135XV60D 8811455EL16XC1-048-230A TXV 47,500 15.1 12.5 CX35-60D SL280UH135V60D 8811456EL16XC1-048-230A TXV 47,500 14.5 12.5 CX35-60D SLP98UH135XV60D 8811457EL16XC1-048-230A TXV 47,000 14.25 12.2 CX35-60D 8811458EL16XC1-060-230A TXV 59,000 14 12 C33-49 9040144EL16XC1-060-230A TXV 59,000 14.5 12.2 C33-49C EL180UH090E60C 9040131EL16XC1-060-230A TXV 58,500 14.25 12.2 C33-49C EL180UH110E60C 9040132EL16XC1-060-230A TXV 58,500 14.25 12.2 C33-49C EL180UH110XE60C 9040133EL16XC1-060-230A TXV 58,500 14.25 12.2 C33-49C EL195UH110XE60C 9040134EL16XC1-060-230A TXV 58,000 14.25 12 C33-49C EL296UH090XV60C 9040135EL16XC1-060-230A TXV 58,500 14.25 12.2 C33-49C EL296UH110XE60C 9040136EL16XC1-060-230A TXV 58,000 14.25 12.2 C33-49C EL296UH110XV60C 9040137EL16XC1-060-230A TXV 59,000 14.5 12.2 C33-49C SL280UH090V60C 9040138EL16XC1-060-230A TXV 59,000 14.5 12.2 C33-49C SL280UH090XV60C 9040139EL16XC1-060-230A TXV 58,500 14.5 12.2 C33-49C SL280UH110V60C 9040140EL16XC1-060-230A TXV 58,500 14.5 12.2 C33-49C SL280UH110XV60C 9040141NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 86: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 86

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-060-230A TXV 58,000 14.25 12.2 C33-49C SLP98UH090XV60C 9040142EL16XC1-060-230A TXV 58,000 14.25 12.2 C33-49C SLP98UH110XV60C 9040143EL16XC1-060-230A TXV 59,000 14 12 C33-49C 9040145EL16XC1-060-230A TXV 57,500 14.2 12 C33-50/60C EL180UH090E60C 9040146EL16XC1-060-230A TXV 57,000 14 11.7 C33-50/60C EL180UH110E60C 9040147EL16XC1-060-230A TXV 57,000 14 11.7 C33-50/60C EL180UH110XE60C 9040148EL16XC1-060-230A TXV 57,000 14 11.7 C33-50/60C EL195UH110XE60C 9040149EL16XC1-060-230A TXV 57,000 14 11.7 C33-50/60C EL296UH110XE60C 9040150EL16XC1-060-230A TXV 57,000 14 11.7 C33-50/60C SL280UH090V60C 9040151EL16XC1-060-230A TXV 57,000 14 11.7 C33-50/60C SL280UH090XV60C 9040152EL16XC1-060-230A TXV 59,000 14.5 12.2 C33-60D EL180UH135E60D 9040153EL16XC1-060-230A TXV 59,000 14 12 C33-60D EL195UH135XE60D 9040154EL16XC1-060-230A TXV 59,000 14 12 C33-60D EL296UH135XE60D 9040155EL16XC1-060-230A TXV 58,000 14.5 12.2 C33-60D EL296UH135XV60D 9040156EL16XC1-060-230A TXV 58,500 14.5 12.5 C33-60D SL280UH135V60D 9040157EL16XC1-060-230A TXV 58,000 14.5 12.2 C33-60D SLP98UH135XV60D 9040158EL16XC1-060-230A TXV 58,500 14 11.7 C33-60D 9040159EL16XC1-060-230A TXV 59,500 14.5 12.5 C33-62C EL180UH090E60C 9040160EL16XC1-060-230A TXV 59,500 14.5 12.5 C33-62C EL180UH110E60C 9040161EL16XC1-060-230A TXV 59,500 14.5 12.5 C33-62C EL180UH110XE60C 9040162EL16XC1-060-230A TXV 59,500 14.5 12.2 C33-62C EL195UH110XE60C 9040163EL16XC1-060-230A TXV 59,000 14.5 12.2 C33-62C EL296UH090XV60C 9040164EL16XC1-060-230A TXV 59,500 14.5 12.2 C33-62C EL296UH110XE60C 9040165EL16XC1-060-230A TXV 59,000 14.5 12.5 C33-62C EL296UH110XV60C 9040166EL16XC1-060-230A TXV 60,000 14.5 12.5 C33-62C SL280UH090V60C 9040167EL16XC1-060-230A TXV 60,000 14.5 12.5 C33-62C SL280UH090XV60C 9040168EL16XC1-060-230A TXV 59,500 14.5 12.2 C33-62C SL280UH110V60C 9040169EL16XC1-060-230A TXV 59,500 14.5 12.2 C33-62C SL280UH110XV60C 9040170EL16XC1-060-230A TXV 59,000 14.5 12.2 C33-62C SLP98UH090XV60C 9040171EL16XC1-060-230A TXV 59,000 14.5 12.5 C33-62C SLP98UH110XV60C 9040172EL16XC1-060-230A TXV 60,000 14.25 12.2 C33-62C 9040173EL16XC1-060-230A TXV 60,000 14.25 12.2 C33-62C 9040174EL16XC1-060-230A TXV 59,500 14.5 12.5 C33-62D EL180UH135E60D 9040175EL16XC1-060-230A TXV 59,500 14.25 12.2 C33-62D EL195UH135XE60D 9040176EL16XC1-060-230A TXV 59,500 14.25 12.2 C33-62D EL296UH135XE60D 9040177EL16XC1-060-230A TXV 58,500 14.5 12.2 C33-62D EL296UH135XV60D 9040178EL16XC1-060-230A TXV 59,000 15 12.5 C33-62D SL280UH135V60D 9040179EL16XC1-060-230A TXV 58,500 14.5 12.2 C33-62D SLP98UH135XV60D 9040180EL16XC1-060-230A TXV 59,000 14 12 C33-62D 9040182EL16XC1-060-230A TXV 59,500 14 12.2 C33-62D 9040181EL16XC1-060-230A TXV 59,000 14.5 12.2 C35-49C EL180UH090E60C 9040183EL16XC1-060-230A TXV 59,000 14.5 12.2 C35-49C EL180UH110E60C 9040185EL16XC1-060-230A TXV 59,000 14.5 12.2 C35-49C EL180UH110XE60C 9040184EL16XC1-060-230A TXV 58,500 14.25 12.2 C35-49C EL195UH110XE60C 9040186EL16XC1-060-230A TXV 58,000 14.25 12 C35-49C EL296UH090XV60C 9040187EL16XC1-060-230A TXV 58,500 14.25 12.2 C35-49C EL296UH110XE60C 9040188EL16XC1-060-230A TXV 58,000 14.25 12.2 C35-49C EL296UH110XV60C 9040189EL16XC1-060-230A TXV 59,000 14.5 12.2 C35-49C SL280UH090V60C 9040190EL16XC1-060-230A TXV 59,000 14.5 12.2 C35-49C SL280UH090XV60C 9040191NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 87: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 87

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-060-230A TXV 59,000 14.25 12.2 C35-49C SL280UH110V60C 9040192EL16XC1-060-230A TXV 59,000 14.25 12.2 C35-49C SL280UH110XV60C 9040193EL16XC1-060-230A TXV 58,000 14.25 12 C35-49C SLP98UH090XV60C 9040194EL16XC1-060-230A TXV 58,000 14.25 12.2 C35-49C SLP98UH110XV60C 9040195EL16XC1-060-230A TXV 59,000 14 12 C35-49C 9040196EL16XC1-060-230A TXV 57,500 14.25 12 C35-50/60C EL180UH090E60C 9040197EL16XC1-060-230A TXV 57,500 14 12 C35-50/60C EL180UH110E60C 9040198EL16XC1-060-230A TXV 57,500 14 12 C35-50/60C EL180UH110XE60C 9040199EL16XC1-060-230A TXV 57,500 14 12 C35-50/60C EL195UH110XE60C 9040200EL16XC1-060-230A TXV 57,500 14 12 C35-50/60C EL296UH110XE60C 9040201EL16XC1-060-230A TXV 57,500 14 11.7 C35-50/60C SL280UH090V60C 9040202EL16XC1-060-230A TXV 57,500 14 11.7 C35-50/60C SL280UH090XV60C 9040203EL16XC1-060-230A TXV 60,000 14.5 12.5 C35-60C EL180UH090E60C 9040204EL16XC1-060-230A TXV 59,500 14.5 12.5 C35-60C EL180UH110E60C 9040205EL16XC1-060-230A TXV 59,500 14.5 12.5 C35-60C EL180UH110XE60C 9040206EL16XC1-060-230A TXV 59,500 14.5 12.2 C35-60C EL195UH110XE60C 9040207EL16XC1-060-230A TXV 59,000 14.5 12.2 C35-60C EL296UH090XV60C 9040208EL16XC1-060-230A TXV 59,500 14.5 12.2 C35-60C EL296UH110XE60C 9040209EL16XC1-060-230A TXV 59,000 14.5 12.5 C35-60C EL296UH110XV60C 9040210EL16XC1-060-230A TXV 60,000 14.5 12.5 C35-60C SL280UH090V60C 9040211EL16XC1-060-230A TXV 60,000 14.5 12.5 C35-60C SL280UH090XV60C 9040212EL16XC1-060-230A TXV 59,500 14.5 12.2 C35-60C SL280UH110V60C 9040213EL16XC1-060-230A TXV 59,500 14.5 12.2 C35-60C SL280UH110XV60C 9040214EL16XC1-060-230A TXV 59,000 14.5 12.2 C35-60C SLP98UH090XV60C 9040215EL16XC1-060-230A TXV 59,000 14.5 12.5 C35-60C SLP98UH110XV60C 9040216EL16XC1-060-230A TXV 60,000 14.25 12.2 C35-60C 9040217EL16XC1-060-230A TXV 60,000 14.5 12.5 C35-60D EL180UH135E60D 9040218EL16XC1-060-230A TXV 60,000 14.25 12.2 C35-60D EL195UH135XE60D 9040219EL16XC1-060-230A TXV 60,000 14.25 12.2 C35-60D EL296UH135XE60D 9040220EL16XC1-060-230A TXV 59,000 14.5 12.5 C35-60D EL296UH135XV60D 9040221EL16XC1-060-230A TXV 59,500 14.5 12.5 C35-60D SL280UH135V60D 9040222EL16XC1-060-230A TXV 59,500 15 12.5 C35-60D SLP98UH135XV60D 9040223EL16XC1-060-230A TXV 59,500 14 12 C35-60D 9040224EL16XC1-060-230A TXV 58,500 14.5 12.2 CBA27UHE-060 10259416EL16XC1-060-230A TXV 59,500 14.25 12.2 CBX25UH-060 9040225EL16XC1-060-230A TXV 59,500 15.1 12.5 CBX25UHV-060 9040226EL16XC1-060-230A TXV 59,000 14.5 12.2 CBX27UH-060 9040227EL16XC1-060-230A TXV 58,500 14.25 12.2 CBX32M-060 9040228EL16XC1-060-230A TXV 58,000 14.25 12 CBX32MV-048 9040229EL16XC1-060-230A TXV 58,500 14.25 12.2 CBX32MV-060 9040230EL16XC1-060-230A TXV 58,500 14.5 12.2 CBX32MV-068 9040231EL16XC1-060-230A TXV 58,500 14.5 12.2 CBX40UHV-060 10278030EL16XC1-060-230A TXV 59,500 14.5 12.5 CH23-65 EL180UH090E60C 9040232EL16XC1-060-230A TXV 59,000 14.5 12.2 CH23-65 EL180UH110E60C 9040233EL16XC1-060-230A TXV 59,500 14.5 12.5 CH23-68 EL180UH135E60D 9040234EL16XC1-060-230A TXV 59,500 14.25 12.2 CH23-68 EL195UH135XE60D 9040235EL16XC1-060-230A TXV 58,500 14.5 12.2 CH23-68 EL296UH090XV60C 9040236EL16XC1-060-230A TXV 59,000 14.5 12.2 CH23-68 EL296UH110XV60C 9040237EL16XC1-060-230A TXV 59,500 14.25 12.2 CH23-68 EL296UH135XE60D 9040238NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 88: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 88

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-060-230A TXV 59,500 14.5 12.2 CH23-68 EL296UH135XV60D 9040239EL16XC1-060-230A TXV 59,000 14.5 12.2 CH23-68 SL280UH110V60C 9040240EL16XC1-060-230A TXV 59,000 15.1 12.5 CH23-68 SL280UH135V60D 9040241EL16XC1-060-230A TXV 59,000 14 12 CH23-68 9040242EL16XC1-060-230A TXV 58,500 14.5 12.2 CH33-49 EL180UH090E60C 9040243EL16XC1-060-230A TXV 58,500 14.5 12.2 CH33-49 EL180UH110E60C 9040244EL16XC1-060-230A TXV 58,500 14.25 12.2 CH33-49 EL195UH110XE60C 9040245EL16XC1-060-230A TXV 58,000 14.25 12 CH33-49 EL296UH090XV60C 9040246EL16XC1-060-230A TXV 58,500 14.25 12.2 CH33-49 EL296UH110XE60C 9040247EL16XC1-060-230A TXV 58,500 14.25 12 CH33-49 EL296UH110XV60C 9040248EL16XC1-060-230A TXV 59,000 14.5 12.2 CH33-49 SL280UH090V60C 9043433EL16XC1-060-230A TXV 58,500 14.25 12.2 CH33-49 SL280UH110V60C 9043435EL16XC1-060-230A TXV 58,000 14.25 12 CH33-49 SLP98UH090XV60C 9040249EL16XC1-060-230A TXV 58,000 14.25 12.2 CH33-49 SLP98UH110XV60C 9040250EL16XC1-060-230A TXV 59,000 14 12 CH33-49 9040252EL16XC1-060-230A TXV 59,500 14 12.2 CH33-49 9040251EL16XC1-060-230A TXV 58,500 14.25 12.2 CH33-50/60C SL280UH090V60C 9043437EL16XC1-060-230A TXV 58,000 14 12 CH33-50/60C SL280UH110V60C 9043438EL16XC1-060-230A TXV 58,500 14 11.7 CH33-50/60C 9040253EL16XC1-060-230A TXV 58,500 14.25 12.2 CH33-60D EL180UH135E60D 9040254EL16XC1-060-230A TXV 58,000 14 11.7 CH33-60D EL195UH135XE60D 9040255EL16XC1-060-230A TXV 58,000 14 11.7 CH33-60D EL296UH135XE60D 9040256EL16XC1-060-230A TXV 58,500 14.25 12.2 CH33-60D EL296UH135XV60D 9040257EL16XC1-060-230A TXV 58,000 14.5 12.5 CH33-60D SL280UH135V60D 9040258EL16XC1-060-230A TXV 58,000 14.25 12.2 CH33-60D SLP98UH135XV60D 9040259EL16XC1-060-230A TXV 59,000 14.5 12.2 CH33-62D EL180UH135E60D 9040260EL16XC1-060-230A TXV 59,000 14.25 12 CH33-62D EL195UH135XE60D 9040261EL16XC1-060-230A TXV 59,000 14.25 12 CH33-62D EL296UH135XE60D 9040262EL16XC1-060-230A TXV 59,000 14.25 12.2 CH33-62D EL296UH135XV60D 9040263EL16XC1-060-230A TXV 58,500 14.5 12.5 CH33-62D SL280UH135V60D 9043439EL16XC1-060-230A TXV 58,500 14.5 12.2 CH33-62D SLP98UH135XV60D 9040264EL16XC1-060-230A TXV 58,500 14 11.7 CH33-62D 9040266EL16XC1-060-230A TXV 59,000 14 12 CH33-62D 9040265EL16XC1-060-230A TXV 60,000 14 12 CH35-51C EL180UH090E60C 9040267EL16XC1-060-230A TXV 60,000 14 12 CH35-51C EL180UH110E60C 9040268EL16XC1-060-230A TXV 59,500 14 11.7 CH35-51C EL195UH110XE60C 9040269EL16XC1-060-230A TXV 58,500 14.25 12.2 CH35-51C EL296UH090XV60C 9040270EL16XC1-060-230A TXV 59,500 14 11.7 CH35-51C EL296UH110XE60C 9040271EL16XC1-060-230A TXV 59,000 14.25 12.2 CH35-51C EL296UH110XV60C 9040272EL16XC1-060-230A TXV 59,000 14.25 12.2 CH35-51C SL280UH090V60C 9043440EL16XC1-060-230A TXV 58,500 14.25 12 CH35-51C SL280UH110V60C 9043441EL16XC1-060-230A TXV 58,500 14.25 12.2 CH35-51C SLP98UH090XV60C 9040273EL16XC1-060-230A TXV 58,500 14.5 12.2 CH35-51C SLP98UH110XV60C 9040274EL16XC1-060-230A TXV 59,000 14 12 CH35-51C 9040275EL16XC1-060-230A TXV 59,000 14.5 12.2 CH35-60D EL180UH135E60D 9040276EL16XC1-060-230A TXV 59,000 14.25 12 CH35-60D EL195UH135XE60D 9040277EL16XC1-060-230A TXV 59,000 14.25 12 CH35-60D EL296UH135XE60D 9040278EL16XC1-060-230A TXV 59,500 14.5 12.2 CH35-60D EL296UH135XV60D 9040279EL16XC1-060-230A TXV 58,500 14.5 12.5 CH35-60D SL280UH135V60D 9043442NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 89: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 89

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-060-230A TXV 59,000 14.5 12.2 CH35-60D SLP98UH135XV60D 9040280EL16XC1-060-230A TXV 59,000 14 12 CH35-60D 9040281EL16XC1-060-230A TXV 57,500 14.25 12 CR33-50/60 EL180DF110E60C 9040282EL16XC1-060-230A TXV 57,500 14.25 12 CR33-50/60 EL195DF110XE60C 9040283EL16XC1-060-230A TXV 57,500 14.25 12 CR33-50/60 EL296DF110XE60C 9040284EL16XC1-060-230A TXV 57,000 14 11.7 CR33-50/60 SL280DF090V60C 9040285EL16XC1-060-230A TXV 57,500 14 12 CR33-50/60 SL280DF110V60C 9040286EL16XC1-060-230A TXV 59,000 14.5 12.2 CX34-49C EL180UH090E60C 9040287EL16XC1-060-230A TXV 58,500 14.25 12.2 CX34-49C EL180UH110E60C 9040288EL16XC1-060-230A TXV 58,500 14.25 12.2 CX34-49C EL180UH110XE60C 9040289EL16XC1-060-230A TXV 58,500 14.25 12.2 CX34-49C EL195UH110XE60C 9040290EL16XC1-060-230A TXV 58,000 14.25 12 CX34-49C EL296UH090XV60C 9040291EL16XC1-060-230A TXV 58,500 14.25 12.2 CX34-49C EL296UH110XE60C 9040292EL16XC1-060-230A TXV 58,000 14.25 12.2 CX34-49C EL296UH110XV60C 9040293EL16XC1-060-230A TXV 59,000 14.5 12.2 CX34-49C SL280UH090V60C 9040294EL16XC1-060-230A TXV 59,000 14.5 12.2 CX34-49C SL280UH090XV60C 9040295EL16XC1-060-230A TXV 58,500 14.5 12.2 CX34-49C SL280UH110V60C 9040296EL16XC1-060-230A TXV 58,500 14.5 12.2 CX34-49C SL280UH110XV60C 9040297EL16XC1-060-230A TXV 58,000 14.25 12.2 CX34-49C SLP98UH090XV60C 9040298EL16XC1-060-230A TXV 58,000 14.25 12.2 CX34-49C SLP98UH110XV60C 9040299EL16XC1-060-230A TXV 59,000 14 12 CX34-49C 9040300EL16XC1-060-230A TXV 57,500 14.25 12 CX34-50/60C EL180UH090E60C 9040301EL16XC1-060-230A TXV 57,000 14 12 CX34-50/60C EL180UH110E60C 9040302EL16XC1-060-230A TXV 57,000 14 12 CX34-50/60C EL180UH110XE60C 9040303EL16XC1-060-230A TXV 57,000 14 12 CX34-50/60C EL195UH110XE60C 9040304EL16XC1-060-230A TXV 57,000 14 12 CX34-50/60C EL296UH110XE60C 9040305EL16XC1-060-230A TXV 57,000 14 11.7 CX34-50/60C SL280UH090V60C 9040306EL16XC1-060-230A TXV 57,000 14 11.7 CX34-50/60C SL280UH090XV60C 9040307EL16XC1-060-230A TXV 59,000 14.5 12.2 CX34-60D EL180UH135E60D 9040308EL16XC1-060-230A TXV 59,000 14 12 CX34-60D EL195UH135XE60D 9040309EL16XC1-060-230A TXV 59,000 14 12 CX34-60D EL296UH135XE60D 9040310EL16XC1-060-230A TXV 58,000 14.5 12.2 CX34-60D EL296UH135XV60D 9040311EL16XC1-060-230A TXV 58,500 14.5 12.5 CX34-60D SL280UH135V60D 9040312EL16XC1-060-230A TXV 58,000 14.5 12.2 CX34-60D SLP98UH135XV60D 9040313EL16XC1-060-230A TXV 58,500 14 11.7 CX34-60D 9040314EL16XC1-060-230A TXV 59,500 14.5 12.5 CX34-62C EL180UH090E60C 9040315EL16XC1-060-230A TXV 59,500 14.5 12.5 CX34-62C EL180UH110E60C 9040316EL16XC1-060-230A TXV 59,500 14.5 12.5 CX34-62C EL180UH110XE60C 9040317EL16XC1-060-230A TXV 59,500 14.5 12.2 CX34-62C EL195UH110XE60C 9040318EL16XC1-060-230A TXV 59,000 14.5 12.2 CX34-62C EL296UH090XV60C 9040319EL16XC1-060-230A TXV 59,500 14.5 12.2 CX34-62C EL296UH110XE60C 9040320EL16XC1-060-230A TXV 59,000 14.5 12.5 CX34-62C EL296UH110XV60C 9040321EL16XC1-060-230A TXV 60,000 14.5 12.5 CX34-62C SL280UH090V60C 9040322EL16XC1-060-230A TXV 60,000 14.5 12.5 CX34-62C SL280UH090XV60C 9040323EL16XC1-060-230A TXV 59,500 14.5 12.2 CX34-62C SL280UH110V60C 9040324EL16XC1-060-230A TXV 59,500 14.5 12.2 CX34-62C SL280UH110XV60C 9040325EL16XC1-060-230A TXV 59,000 14.5 12.2 CX34-62C SLP98UH090XV60C 9040326EL16XC1-060-230A TXV 59,000 14.5 12.5 CX34-62C SLP98UH110XV60C 9040327EL16XC1-060-230A TXV 60,000 14.25 12.2 CX34-62C 9040328NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 90: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 90

AHRI SYSTEM MATCHES - ALL REGIONS - 018-024-030-041-042-047-048-060NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1-060-230A TXV 59,500 14.5 12.5 CX34-62D EL180UH135E60D 9040329EL16XC1-060-230A TXV 59,500 14.25 12.2 CX34-62D EL195UH135XE60D 9040330EL16XC1-060-230A TXV 59,500 14.25 12.2 CX34-62D EL296UH135XE60D 9040331EL16XC1-060-230A TXV 58,500 14.5 12.2 CX34-62D EL296UH135XV60D 9040332EL16XC1-060-230A TXV 59,000 15 12.5 CX34-62D SL280UH135V60D 9040333EL16XC1-060-230A TXV 58,500 14.5 12.2 CX34-62D SLP98UH135XV60D 9040334EL16XC1-060-230A TXV 59,000 14 12 CX34-62D 9040335EL16XC1-060-230A TXV 59,000 14.5 12.2 CX35-49C EL180UH090E60C 9040336EL16XC1-060-230A TXV 59,000 14.5 12.2 CX35-49C EL180UH110E60C 9040337EL16XC1-060-230A TXV 59,000 14.5 12.2 CX35-49C EL180UH110XE60C 9040338EL16XC1-060-230A TXV 58,500 14.25 12.2 CX35-49C EL195UH110XE60C 9040339EL16XC1-060-230A TXV 58,000 14.25 12 CX35-49C EL296UH090XV60C 9040340EL16XC1-060-230A TXV 58,500 14.25 12.2 CX35-49C EL296UH110XE60C 9040341EL16XC1-060-230A TXV 58,000 14.25 12.2 CX35-49C EL296UH110XV60C 9040342EL16XC1-060-230A TXV 59,000 14.5 12.2 CX35-49C SL280UH090V60C 9040343EL16XC1-060-230A TXV 59,000 14.5 12.2 CX35-49C SL280UH090XV60C 9040344EL16XC1-060-230A TXV 59,000 14.25 12.2 CX35-49C SL280UH110V60C 9040345EL16XC1-060-230A TXV 59,000 14.25 12.2 CX35-49C SL280UH110XV60C 9040346EL16XC1-060-230A TXV 58,000 14.25 12 CX35-49C SLP98UH090XV60C 9040347EL16XC1-060-230A TXV 58,000 14.25 12.2 CX35-49C SLP98UH110XV60C 9040348EL16XC1-060-230A TXV 59,000 14 12 CX35-49C 9040349EL16XC1-060-230A TXV 57,500 14.25 12 CX35-50/60C EL180UH090E60C 9040350EL16XC1-060-230A TXV 57,500 14 12 CX35-50/60C EL180UH110E60C 9040351EL16XC1-060-230A TXV 57,500 14 12 CX35-50/60C EL180UH110XE60C 9040352EL16XC1-060-230A TXV 57,500 14 12 CX35-50/60C EL195UH110XE60C 9040353EL16XC1-060-230A TXV 57,500 14 12 CX35-50/60C EL296UH110XE60C 9040354EL16XC1-060-230A TXV 57,500 14 11.7 CX35-50/60C SL280UH090V60C 9040355EL16XC1-060-230A TXV 57,500 14 11.7 CX35-50/60C SL280UH090XV60C 9040356EL16XC1-060-230A TXV 60,000 14.5 12.5 CX35-60C EL180UH090E60C 9040357EL16XC1-060-230A TXV 59,500 14.5 12.5 CX35-60C EL180UH110E60C 9040358EL16XC1-060-230A TXV 59,500 14.5 12.5 CX35-60C EL180UH110XE60C 9040359EL16XC1-060-230A TXV 59,500 14.5 12.2 CX35-60C EL195UH110XE60C 9040360EL16XC1-060-230A TXV 59,000 14.5 12.2 CX35-60C EL296UH090XV60C 9040361EL16XC1-060-230A TXV 59,500 14.5 12.2 CX35-60C EL296UH110XE60C 9040362EL16XC1-060-230A TXV 59,000 14.5 12.5 CX35-60C EL296UH110XV60C 9040363EL16XC1-060-230A TXV 60,000 14.5 12.5 CX35-60C SL280UH090V60C 9040364EL16XC1-060-230A TXV 60,000 14.5 12.5 CX35-60C SL280UH090XV60C 9040365EL16XC1-060-230A TXV 59,500 14.5 12.2 CX35-60C SL280UH110V60C 9040366EL16XC1-060-230A TXV 59,500 14.5 12.2 CX35-60C SL280UH110XV60C 9040367EL16XC1-060-230A TXV 59,000 14.5 12.2 CX35-60C SLP98UH090XV60C 9040368EL16XC1-060-230A TXV 59,000 14.5 12.5 CX35-60C SLP98UH110XV60C 9040369EL16XC1-060-230A TXV 60,000 14.25 12.2 CX35-60C 9040370EL16XC1-060-230A TXV 60,000 14.5 12.5 CX35-60D EL180UH135E60D 9040371EL16XC1-060-230A TXV 60,000 14.25 12.2 CX35-60D EL195UH135XE60D 9040372EL16XC1-060-230A TXV 60,000 14.25 12.2 CX35-60D EL296UH135XE60D 9040373EL16XC1-060-230A TXV 59,000 14.5 12.5 CX35-60D EL296UH135XV60D 9040374EL16XC1-060-230A TXV 59,500 15 12.5 CX35-60D SL280UH135V60D 9040375EL16XC1-060-230A TXV 59,500 15 12.5 CX35-60D SLP98UH135XV60D 9040376EL16XC1-060-230A TXV 59,500 14 12 CX35-60D 9040377NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 91: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 91

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B RFC 34,200 14.25 12.2 C33-38A 9125506EL16XC1S036-230B RFC 34,200 14.25 12.2 C33-38B 9125522EL16XC1S036-230B RFC 34,400 14.25 12.2 C33-43 9125552EL16XC1S036-230B RFC 34,800 14.5 12.2 C33-49 9125613EL16XC1S036-230B RFC 34,200 14.25 12.2 C33-50/60C 9125633EL16XC1S036-230B RFC 34,200 14.25 12.2 CH33-31B 9125853EL16XC1S036-230B RFC 35,000 14.5 12.2 CH33-43B 9125915EL16XC1S036-230B RFC 34,200 14.25 12.2 CH33-44/48B 9125949EL16XC1S036-230B RFC 34,400 14.25 12.2 CH33-48 9125969EL16XC1S036-230B RFC 34,800 14.5 12.2 CH33-49 9125989EL16XC1S036-230B RFC 34,600 14.5 12.2 CH33-50/60C 9126009EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-31A EL180UH045E36A 9125454EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-31A EL180UH045XE36A 9125455EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31A SL280UH070V36A 9125456EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31A SL280UH070XV36A 9125457EL16XC1S036-230B TXV 34,200 14.5 12 C33-31A 9126439EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31B EL180UH070E36B 9125458EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31B EL180UH070XE36B 9125459EL16XC1S036-230B TXV 34,400 15.5 12.5 C33-31B EL180UH090E48B 9125460EL16XC1S036-230B TXV 34,400 15.5 12.5 C33-31B EL180UH090XE48B 9125461EL16XC1S036-230B TXV 34,400 14.5 12.2 C33-31B EL195UH045XE36B 9125462EL16XC1S036-230B TXV 34,200 15.1 12.5 C33-31B EL195UH070XE36B 9125463EL16XC1S036-230B TXV 34,400 14.5 12.2 C33-31B EL296UH045XE36B 9125464EL16XC1S036-230B TXV 34,400 15.1 12.5 C33-31B EL296UH045XV36B 9125465EL16XC1S036-230B TXV 34,200 15.1 12.5 C33-31B EL296UH070XE36B 9125466EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31B EL296UH070XV36B 9125467EL16XC1S036-230B TXV 34,600 16 13 C33-31B SL280UH090V36B 9125468EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-31B SL280UH090V48B 9125469EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-31B SL280UH090XV48B 9125470EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31B SLP98UH070XV36B 9125471EL16XC1S036-230B TXV 34,200 14.5 12 C33-31B 9126440EL16XC1S036-230B TXV 33,600 14.5 12.2 C33-36A EL180UH045E36A 9125472EL16XC1S036-230B TXV 33,600 14.5 12.2 C33-36A EL180UH045XE36A 9125473EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-36A SL280UH070V36A 9125474EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-36A SL280UH070XV36A 9125475EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36B EL180UH070E36B 9125476EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36B EL180UH070XE36B 9125477EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36B EL180UH090E48B 9125478EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36B EL180UH090XE48B 9125479EL16XC1S036-230B TXV 33,000 15.1 12.2 C33-36B EL195UH045XE36B 9125480EL16XC1S036-230B TXV 33,400 15.1 12.5 C33-36B EL195UH070XE36B 9125481EL16XC1S036-230B TXV 33,000 15.1 12.2 C33-36B EL296UH045XE36B 9125482EL16XC1S036-230B TXV 33,000 14.5 12.2 C33-36B EL296UH045XV36B 9125483EL16XC1S036-230B TXV 33,400 15.1 12.5 C33-36B EL296UH070XE36B 9125484EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-36B EL296UH070XV36B 9125485EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36B SL280UH090V36B 9125486EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36B SL280UH090V48B 9125487EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36B SL280UH090XV48B 9125488EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-36B SLP98UH070XV36B 9125489NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 92: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 92

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36C EL180UH090E60C 9125490EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36C EL180UH110E60C 9125491EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36C EL180UH110XE60C 9125492EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36C EL195UH090XE48C 9125493EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36C EL195UH110XE60C 9125494EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36C EL296UH090XE48C 9125495EL16XC1S036-230B TXV 33,600 15.1 12.5 C33-36C EL296UH090XV36C 9125496EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36C EL296UH090XV48C 9125497EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36C EL296UH110XE60C 9125498EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36C EL296UH110XV48C 9125499EL16XC1S036-230B TXV 33,600 15.1 12.5 C33-36C SLP98UH090XV36C 9125500EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36C SLP98UH090XV48C 9125501EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38A EL180UH045E36A 9125502EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38A EL180UH045XE36A 9125503EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38A SL280UH070V36A 9125504EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38A SL280UH070XV36A 9125505EL16XC1S036-230B TXV 34,600 14.5 12.2 C33-38A 9125507EL16XC1S036-230B TXV 34,800 16 13 C33-38B EL180UH070E36B 9125508EL16XC1S036-230B TXV 34,800 16 13 C33-38B EL180UH070XE36B 9125509EL16XC1S036-230B TXV 35,200 16 13 C33-38B EL180UH090E48B 9125510EL16XC1S036-230B TXV 35,200 16 13 C33-38B EL180UH090XE48B 9125511EL16XC1S036-230B TXV 34,800 15.1 12.5 C33-38B EL195UH045XE36B 9125512EL16XC1S036-230B TXV 34,800 15.5 12.5 C33-38B EL195UH070XE36B 9125513EL16XC1S036-230B TXV 34,800 15.1 12.5 C33-38B EL296UH045XE36B 9125514EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38B EL296UH045XV36B 9125515EL16XC1S036-230B TXV 34,800 15.5 12.5 C33-38B EL296UH070XE36B 9125516EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38B EL296UH070XV36B 9125517EL16XC1S036-230B TXV 35,000 16 13 C33-38B SL280UH090V36B 9125518EL16XC1S036-230B TXV 35,200 16 13 C33-38B SL280UH090V48B 9125519EL16XC1S036-230B TXV 35,200 16 13 C33-38B SL280UH090XV48B 9125520EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38B SLP98UH070XV36B 9125521EL16XC1S036-230B TXV 34,600 14.5 12.2 C33-38B 9125523EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-42 EL180UH070E36B 9125524EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-42 EL180UH070XE36B 9125525EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-42 EL180UH090E48B 9125526EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-42 EL180UH090XE48B 9125527EL16XC1S036-230B TXV 33,000 15.1 12.2 C33-42 EL195UH045XE36B 9125528EL16XC1S036-230B TXV 33,400 15.1 12.5 C33-42 EL195UH070XE36B 9125529EL16XC1S036-230B TXV 33,000 15.1 12.2 C33-42 EL296UH045XE36B 9125530EL16XC1S036-230B TXV 33,000 14.5 12.2 C33-42 EL296UH045XV36B 9125531EL16XC1S036-230B TXV 33,400 15.1 12.5 C33-42 EL296UH070XE36B 9125532EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-42 EL296UH070XV36B 9125533EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-42 SL280UH090V36B 9125534EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-42 SL280UH090V48B 9125535EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-42 SL280UH090XV48B 9125536EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-42 SLP98UH070XV36B 9125537EL16XC1S036-230B TXV 35,200 16 13 C33-43B EL180UH070E36B 9125538EL16XC1S036-230B TXV 35,200 16 13 C33-43B EL180UH070XE36B 9125539EL16XC1S036-230B TXV 35,600 16 13 C33-43B EL180UH090E48B 9125540NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 93: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 93

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,600 16 13 C33-43B EL180UH090XE48B 9125541EL16XC1S036-230B TXV 35,000 15.1 12.5 C33-43B EL195UH045XE36B 9125542EL16XC1S036-230B TXV 35,000 16 13 C33-43B EL195UH070XE36B 9125543EL16XC1S036-230B TXV 35,000 15.1 12.5 C33-43B EL296UH045XE36B 9125544EL16XC1S036-230B TXV 35,200 15.5 12.5 C33-43B EL296UH045XV36B 9125545EL16XC1S036-230B TXV 35,000 16 13 C33-43B EL296UH070XE36B 9125546EL16XC1S036-230B TXV 35,200 15.5 12.5 C33-43B EL296UH070XV36B 9125547EL16XC1S036-230B TXV 35,200 16 13 C33-43B SL280UH090V36B 9125548EL16XC1S036-230B TXV 35,400 16 13 C33-43B SL280UH090V48B 9125549EL16XC1S036-230B TXV 35,400 16 13 C33-43B SL280UH090XV48B 9125550EL16XC1S036-230B TXV 35,200 15.5 12.5 C33-43B SLP98UH070XV36B 9125551EL16XC1S036-230B TXV 34,800 14.5 12.2 C33-43B 9125553EL16XC1S036-230B TXV 35,600 16 13 C33-43C EL180UH090E60C 9125554EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL180UH110E60C 9125555EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL180UH110XE60C 9125556EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL195UH090XE48C 9125557EL16XC1S036-230B TXV 35,600 16 13 C33-43C EL195UH110XE60C 9125558EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL296UH090XE48C 9125559EL16XC1S036-230B TXV 35,400 16 13 C33-43C EL296UH090XV36C 9125560EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL296UH090XV48C 9125561EL16XC1S036-230B TXV 35,600 16 13 C33-43C EL296UH110XE60C 9125562EL16XC1S036-230B TXV 35,400 16 13 C33-43C EL296UH110XV48C 9125563EL16XC1S036-230B TXV 35,600 16 13 C33-43C EL296UH110XV60C 9125564EL16XC1S036-230B TXV 35,800 16 13 C33-43C SL280UH090V60C 9125565EL16XC1S036-230B TXV 35,800 16 13 C33-43C SL280UH090XV60C 9125566EL16XC1S036-230B TXV 35,600 16 13 C33-43C SL280UH110V60C 9125567EL16XC1S036-230B TXV 35,600 16 13 C33-43C SL280UH110XV60C 9125568EL16XC1S036-230B TXV 35,400 16 13 C33-43C SLP98UH090XV36C 9125569EL16XC1S036-230B TXV 35,200 16 13 C33-43C SLP98UH090XV48C 9125570EL16XC1S036-230B TXV 35,600 16 13 C33-43C SLP98UH110XV60C 9125571EL16XC1S036-230B TXV 34,400 14.25 12.2 C33-43C 9126453EL16XC1S036-230B TXV 34,800 14.5 12.2 C33-43C 9125572EL16XC1S036-230B TXV 34,200 14.5 12 C33-44C 9126441EL16XC1S036-230B TXV 34,600 16 13 C33-48B EL180UH070E36B 9125573EL16XC1S036-230B TXV 34,600 16 13 C33-48B EL180UH070XE36B 9125574EL16XC1S036-230B TXV 35,000 16 13 C33-48B EL180UH090E48B 9125575EL16XC1S036-230B TXV 35,000 16 13 C33-48B EL180UH090XE48B 9125576EL16XC1S036-230B TXV 34,200 15.5 12.5 C33-48B EL195UH045XE36B 9125577EL16XC1S036-230B TXV 34,400 15.5 12.5 C33-48B EL195UH070XE36B 9125578EL16XC1S036-230B TXV 34,200 15.5 12.5 C33-48B EL296UH045XE36B 9125579EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-48B EL296UH045XV36B 9125580EL16XC1S036-230B TXV 34,400 15.5 12.5 C33-48B EL296UH070XE36B 9125581EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-48B EL296UH070XV36B 9125582EL16XC1S036-230B TXV 34,800 16 13 C33-48B SL280UH090V36B 9125583EL16XC1S036-230B TXV 34,800 16 13 C33-48B SL280UH090V48B 9125584EL16XC1S036-230B TXV 34,800 16 13 C33-48B SL280UH090XV48B 9125585EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-48B SLP98UH070XV36B 9125586EL16XC1S036-230B TXV 34,200 14.5 12 C33-48B 9126442EL16XC1S036-230B TXV 34,600 16 13 C33-48C EL195UH090XE48C 9125587NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 94: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 94

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,000 16 13 C33-48C EL195UH110XE60C 9125588EL16XC1S036-230B TXV 34,600 16 13 C33-48C EL296UH090XE48C 9125589EL16XC1S036-230B TXV 34,800 16 13 C33-48C EL296UH090XV36C 9125590EL16XC1S036-230B TXV 34,600 16 13 C33-48C EL296UH090XV48C 9125591EL16XC1S036-230B TXV 35,000 16 13 C33-48C EL296UH110XE60C 9125592EL16XC1S036-230B TXV 34,800 16 13 C33-48C SLP98UH090XV36C 9125593EL16XC1S036-230B TXV 34,600 16 13 C33-48C SLP98UH090XV48C 9125594EL16XC1S036-230B TXV 34,200 14.5 12 C33-48C 9126443EL16XC1S036-230B TXV 35,800 16 13 C33-49 EL180UH090E60C 9125595EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL180UH110E60C 9125596EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL180UH110XE60C 9125597EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL195UH090XE48C 9125598EL16XC1S036-230B TXV 36,000 16 13 C33-49 EL195UH110XE60C 9125599EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL296UH090XE48C 9125600EL16XC1S036-230B TXV 35,800 16 13 C33-49 EL296UH090XV36C 9125601EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL296UH090XV48C 9125602EL16XC1S036-230B TXV 36,000 16 13 C33-49 EL296UH110XE60C 9125603EL16XC1S036-230B TXV 35,800 16 13 C33-49 EL296UH110XV48C 9125604EL16XC1S036-230B TXV 36,000 16 13 C33-49 EL296UH110XV60C 9125605EL16XC1S036-230B TXV 36,000 16 13 C33-49 SL280UH090V60C 9125606EL16XC1S036-230B TXV 36,000 16 13 C33-49 SL280UH090XV60C 9125607EL16XC1S036-230B TXV 36,000 16 13 C33-49 SL280UH110V60C 9125608EL16XC1S036-230B TXV 36,000 16 13 C33-49 SL280UH110XV60C 9125609EL16XC1S036-230B TXV 35,800 16 13 C33-49 SLP98UH090XV36C 9125610EL16XC1S036-230B TXV 35,600 16 13 C33-49 SLP98UH090XV48C 9125611EL16XC1S036-230B TXV 36,000 16 13 C33-49 SLP98UH110XV60C 9125612EL16XC1S036-230B TXV 35,200 14.5 12.2 C33-49 9125614EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C EL180UH090E60C 9125615EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL180UH110E60C 9125616EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL180UH110XE60C 9125617EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL195UH090XE48C 9125618EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C EL195UH110XE60C 9125619EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL296UH090XE48C 9125620EL16XC1S036-230B TXV 35,200 16 13 C33-50/60C EL296UH090XV36C 9125621EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL296UH090XV48C 9125622EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C EL296UH110XE60C 9125623EL16XC1S036-230B TXV 35,200 16 13 C33-50/60C EL296UH110XV48C 9125624EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C EL296UH110XV60C 9125625EL16XC1S036-230B TXV 35,600 16 13 C33-50/60C SL280UH090V60C 9125626EL16XC1S036-230B TXV 35,600 16 13 C33-50/60C SL280UH090XV60C 9125627EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C SL280UH110V60C 9125628EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C SL280UH110XV60C 9125629EL16XC1S036-230B TXV 35,200 16 13 C33-50/60C SLP98UH090XV36C 9125630EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C SLP98UH090XV48C 9125631EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C SLP98UH110XV60C 9125632EL16XC1S036-230B TXV 34,600 14.5 12.2 C33-50/60C 9125634EL16XC1S036-230B TXV 33,600 15.1 12.2 C35-30/36A EL180UH045E36A 9125635EL16XC1S036-230B TXV 33,600 15.1 12.2 C35-30/36A EL180UH045XE36A 9125636EL16XC1S036-230B TXV 33,400 15.1 12.5 C35-30/36A SL280UH070V36A 9125637NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 95: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 95

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,400 15.1 12.5 C35-30/36A SL280UH070XV36A 9125638EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36B EL180UH070E36B 9125639EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36B EL180UH070XE36B 9125640EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36B EL180UH090E48B 9125641EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36B EL180UH090XE48B 9125642EL16XC1S036-230B TXV 33,200 15.1 12.5 C35-30/36B EL195UH045XE36B 9125643EL16XC1S036-230B TXV 33,200 15.1 12.5 C35-30/36B EL296UH045XE36B 9125644EL16XC1S036-230B TXV 33,200 15.1 12.2 C35-30/36B EL296UH045XV36B 9125645EL16XC1S036-230B TXV 33,400 15.1 12.5 C35-30/36B EL296UH070XV36B 9125646EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36B SL280UH090V36B 9125647EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36B SL280UH090V48B 9125648EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36B SL280UH090XV48B 9125649EL16XC1S036-230B TXV 33,400 15.1 12.5 C35-30/36B SLP98UH070XV36B 9125650EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36C EL180UH090E60C 9125651EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL180UH110E60C 9125652EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL180UH110XE60C 9125653EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL195UH090XE48C 9125654EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36C EL195UH110XE60C 9125655EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL296UH090XE48C 9125656EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36C EL296UH090XV36C 9125657EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL296UH090XV48C 9125658EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36C EL296UH110XE60C 9125659EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36C EL296UH110XV48C 9125660EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36C SLP98UH090XV36C 9125661EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C SLP98UH090XV48C 9125662EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36C SLP98UH110XV60C 9125663EL16XC1S036-230B TXV 34,800 15.5 12.5 C35-30A EL180UH045E36A 9125664EL16XC1S036-230B TXV 34,800 15.5 12.5 C35-30A EL180UH045XE36A 9125665EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30A SL280UH070V36A 9125666EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30A SL280UH070XV36A 9125667EL16XC1S036-230B TXV 34,400 16 13 C35-30B EL180UH070E36B 9125668EL16XC1S036-230B TXV 34,400 16 13 C35-30B EL180UH070XE36B 9125669EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30B EL180UH090E48B 9125670EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30B EL180UH090XE48B 9125671EL16XC1S036-230B TXV 34,400 14.5 12.2 C35-30B EL195UH045XE36B 9125672EL16XC1S036-230B TXV 34,400 15.5 12.5 C35-30B EL195UH070XE36B 9125673EL16XC1S036-230B TXV 34,400 14.5 12.2 C35-30B EL296UH045XE36B 9125674EL16XC1S036-230B TXV 34,600 15.1 12.5 C35-30B EL296UH045XV36B 9125675EL16XC1S036-230B TXV 34,400 15.5 12.5 C35-30B EL296UH070XE36B 9125676EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30B EL296UH070XV36B 9125677EL16XC1S036-230B TXV 34,800 16 13 C35-30B SL280UH090V36B 9125678EL16XC1S036-230B TXV 34,800 16 13 C35-30B SL280UH090V48B 9125679EL16XC1S036-230B TXV 34,800 16 13 C35-30B SL280UH090XV48B 9125680EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30B SLP98UH070XV36B 9125681EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-36A EL180UH045E36A 9125682EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-36A EL180UH045XE36A 9125683EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36A SL280UH070V36A 9125684EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36A SL280UH070XV36A 9125685EL16XC1S036-230B TXV 34,600 14.5 12.2 C35-36A 9125686NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 96: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 96

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,000 16 13 C35-36B EL180UH070E36B 9125687EL16XC1S036-230B TXV 35,000 16 13 C35-36B EL180UH070XE36B 9125688EL16XC1S036-230B TXV 35,400 16 13 C35-36B EL180UH090E48B 9125689EL16XC1S036-230B TXV 35,400 16 13 C35-36B EL180UH090XE48B 9125690EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-36B EL195UH045XE36B 9125691EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B EL195UH070XE36B 9125692EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-36B EL296UH045XE36B 9125693EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B EL296UH045XV36B 9125694EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B EL296UH070XE36B 9125695EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B EL296UH070XV36B 9125696EL16XC1S036-230B TXV 35,200 16 13 C35-36B SL280UH090V36B 9125697EL16XC1S036-230B TXV 35,200 16 13 C35-36B SL280UH090V48B 9125698EL16XC1S036-230B TXV 35,200 16 13 C35-36B SL280UH090XV48B 9125699EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B SLP98UH070XV36B 9125700EL16XC1S036-230B TXV 34,600 14.5 12.2 C35-36B 9125701EL16XC1S036-230B TXV 35,200 16 13 C35-48B EL180UH070E36B 9125702EL16XC1S036-230B TXV 35,200 16 13 C35-48B EL180UH070XE36B 9125703EL16XC1S036-230B TXV 35,600 16 13 C35-48B EL180UH090E48B 9125704EL16XC1S036-230B TXV 35,600 16 13 C35-48B EL180UH090XE48B 9125705EL16XC1S036-230B TXV 34,800 15.5 12.5 C35-48B EL195UH045XE36B 9125706EL16XC1S036-230B TXV 35,200 16 13 C35-48B EL195UH070XE36B 9125707EL16XC1S036-230B TXV 34,800 15.5 12.5 C35-48B EL296UH045XE36B 9125708EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-48B EL296UH045XV36B 9125709EL16XC1S036-230B TXV 35,200 16 13 C35-48B EL296UH070XE36B 9125710EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-48B EL296UH070XV36B 9125711EL16XC1S036-230B TXV 35,400 16 13 C35-48B SL280UH090V36B 9125712EL16XC1S036-230B TXV 35,400 16 13 C35-48B SL280UH090V48B 9125713EL16XC1S036-230B TXV 35,400 16 13 C35-48B SL280UH090XV48B 9125714EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-48B SLP98UH070XV36B 9125715EL16XC1S036-230B TXV 34,800 14.5 12.2 C35-48B 9125716EL16XC1S036-230B TXV 35,600 16 13 C35-48C EL180UH090E60C 9125717EL16XC1S036-230B TXV 35,200 16 13 C35-48C EL180UH110E60C 9125718EL16XC1S036-230B TXV 35,200 16 13 C35-48C EL180UH110XE60C 9125719EL16XC1S036-230B TXV 35,400 16 13 C35-48C EL195UH090XE48C 9125720EL16XC1S036-230B TXV 35,600 16 13 C35-48C EL195UH110XE60C 9125721EL16XC1S036-230B TXV 35,400 16 13 C35-48C EL296UH090XE48C 9125722EL16XC1S036-230B TXV 35,400 16 13 C35-48C EL296UH090XV36C 9125723EL16XC1S036-230B TXV 35,200 16 13 C35-48C EL296UH090XV48C 9125724EL16XC1S036-230B TXV 35,600 16 13 C35-48C EL296UH110XE60C 9125725EL16XC1S036-230B TXV 35,400 16 13 C35-48C EL296UH110XV48C 9125726EL16XC1S036-230B TXV 35,800 16 13 C35-48C EL296UH110XV60C 9125727EL16XC1S036-230B TXV 35,800 16 13 C35-48C SL280UH090V60C 9125728EL16XC1S036-230B TXV 35,800 16 13 C35-48C SL280UH090XV60C 9125729EL16XC1S036-230B TXV 35,800 16 13 C35-48C SL280UH110V60C 9125730EL16XC1S036-230B TXV 35,800 16 13 C35-48C SL280UH110XV60C 9125731EL16XC1S036-230B TXV 35,400 16 13 C35-48C SLP98UH090XV36C 9125732EL16XC1S036-230B TXV 35,200 16 13 C35-48C SLP98UH090XV48C 9125733EL16XC1S036-230B TXV 35,800 16 13 C35-48C SLP98UH110XV60C 9125734EL16XC1S036-230B TXV 34,800 14.5 12.2 C35-48C 9125735NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 97: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 97

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 36,000 16 13 C35-49C EL180UH090E60C 9125736EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL180UH110E60C 9125737EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL180UH110XE60C 9125738EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL195UH090XE48C 9125739EL16XC1S036-230B TXV 36,000 16 13 C35-49C EL195UH110XE60C 9125740EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL296UH090XE48C 9125741EL16XC1S036-230B TXV 35,800 16 13 C35-49C EL296UH090XV36C 9125742EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL296UH090XV48C 9125743EL16XC1S036-230B TXV 36,000 16 13 C35-49C EL296UH110XE60C 9125744EL16XC1S036-230B TXV 35,800 16 13 C35-49C EL296UH110XV48C 9125745EL16XC1S036-230B TXV 36,000 16 13 C35-49C EL296UH110XV60C 9125746EL16XC1S036-230B TXV 36,000 16 13 C35-49C SL280UH090V60C 9125747EL16XC1S036-230B TXV 36,000 16 13 C35-49C SL280UH090XV60C 9125748EL16XC1S036-230B TXV 36,000 16 13 C35-49C SL280UH110V60C 9125749EL16XC1S036-230B TXV 36,000 16 13 C35-49C SL280UH110XV60C 9125750EL16XC1S036-230B TXV 35,800 16 13 C35-49C SLP98UH090XV36C 9125751EL16XC1S036-230B TXV 35,600 16 13 C35-49C SLP98UH090XV48C 9125752EL16XC1S036-230B TXV 36,000 16 13 C35-49C SLP98UH110XV60C 9125753EL16XC1S036-230B TXV 35,200 14.5 12.2 C35-49C 9125754EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C EL180UH090E60C 9125755EL16XC1S036-230B TXV 35,000 16 13 C35-50/60C EL180UH110E60C 9125756EL16XC1S036-230B TXV 35,000 16 13 C35-50/60C EL180UH110XE60C 9125757EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C EL195UH090XE48C 9125758EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C EL195UH110XE60C 9125759EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C EL296UH090XE48C 9125760EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C EL296UH090XV36C 9125761EL16XC1S036-230B TXV 35,000 16 13 C35-50/60C EL296UH090XV48C 9125762EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C EL296UH110XE60C 9125763EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C EL296UH110XV48C 9125764EL16XC1S036-230B TXV 35,600 16 13 C35-50/60C EL296UH110XV60C 9125765EL16XC1S036-230B TXV 35,600 16 13 C35-50/60C SL280UH090V60C 9125766EL16XC1S036-230B TXV 35,600 16 13 C35-50/60C SL280UH090XV60C 9125767EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C SL280UH110V60C 9125768EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C SL280UH110XV60C 9125769EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C SLP98UH090XV36C 9125770EL16XC1S036-230B TXV 35,000 16 13 C35-50/60C SLP98UH090XV48C 9125771EL16XC1S036-230B TXV 35,600 16 13 C35-50/60C SLP98UH110XV60C 9125772EL16XC1S036-230B TXV 34,600 14.5 12.2 C35-50/60C 9125773EL16XC1S036-230B TXV 34,600 16 13 CBA27UHE-036 10259409EL16XC1S036-230B TXV 35,400 16 13 CBA27UHE-042 10259410EL16XC1S036-230B TXV 33,800 14.5 12 CBX25UH-036 9126444EL16XC1S036-230B TXV 34,600 15.1 12.5 CBX25UH-042 9125774EL16XC1S036-230B TXV 33,800 15.1 12.5 CBX25UHV-036 9125775EL16XC1S036-230B TXV 35,000 16 13 CBX25UHV-042 9125776EL16XC1S036-230B TXV 34,400 16 13 CBX27UH-036 9125777EL16XC1S036-230B TXV 35,200 16 13 CBX27UH-042 9125778EL16XC1S036-230B TXV 33,800 15.1 12.5 CBX32M-030 9125779EL16XC1S036-230B TXV 34,000 14.5 12.2 CBX32M-036 9125780EL16XC1S036-230B TXV 34,000 14.5 12.2 CBX32M-042 9125781NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 98: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 98

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,600 15 12.5 CBX32M-048 9125782EL16XC1S036-230B TXV 34,200 15.1 12.5 CBX32MV-036 9125783EL16XC1S036-230B TXV 35,200 16 13 CBX32MV-048 9125784EL16XC1S036-230B TXV 34,400 15.5 12.5 CBX40UHV-036 9125785EL16XC1S036-230B TXV 35,000 16 13 CBX40UHV-042 9125786EL16XC1S036-230B TXV 35,200 16 13 CBX40UHV-048 9125787EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL180UH045E36A 9125788EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL180UH045XE36A 9125789EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 EL180UH070E36B 9125790EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 EL180UH070XE36B 9125791EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 EL180UH090E48B 9125792EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 EL180UH090XE48B 9125793EL16XC1S036-230B TXV 33,400 15.1 12.5 CH23-41 EL195UH045XE36B 9125794EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL195UH070XE36B 9125795EL16XC1S036-230B TXV 33,400 15.1 12.5 CH23-41 EL296UH045XE36B 9125796EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL296UH045XV36B 9125797EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL296UH070XE36B 9125798EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL296UH070XV36B 9125799EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 SL280UH090V48B 9125800EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 SL280UH090XV48B 9125801EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 SLP98UH070XV36B 9125802EL16XC1S036-230B TXV 33,600 15.1 12.2 CH23-51 EL180UH045E36A 9125803EL16XC1S036-230B TXV 33,600 15.1 12.2 CH23-51 EL180UH045XE36A 9125804EL16XC1S036-230B TXV 33,800 16 13 CH23-51 EL180UH070E36B 9125805EL16XC1S036-230B TXV 33,800 16 13 CH23-51 EL180UH070XE36B 9125806EL16XC1S036-230B TXV 34,200 15.5 12.5 CH23-51 EL180UH090E48B 9125807EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL180UH090E60C 9125808EL16XC1S036-230B TXV 34,200 15.5 12.5 CH23-51 EL180UH090XE48B 9125809EL16XC1S036-230B TXV 34,000 16 13 CH23-51 EL180UH110E60C 9125810EL16XC1S036-230B TXV 34,000 16 13 CH23-51 EL180UH110XE60C 9125811EL16XC1S036-230B TXV 33,400 15.1 12.5 CH23-51 EL195UH045XE36B 9125812EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 EL195UH070XE36B 9125813EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL195UH090XE48C 9125814EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL195UH110XE60C 9125815EL16XC1S036-230B TXV 33,400 15.1 12.5 CH23-51 EL296UH045XE36B 9125816EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 EL296UH045XV36B 9125817EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 EL296UH070XE36B 9125818EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 EL296UH070XV36B 9125819EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL296UH090XE48C 9125820EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 EL296UH090XV36C 9125821EL16XC1S036-230B TXV 33,600 15.5 12.5 CH23-51 EL296UH090XV48C 9125822EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL296UH110XE60C 9125823EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 EL296UH110XV48C 9125824EL16XC1S036-230B TXV 34,200 15.5 12.5 CH23-51 EL296UH110XV60C 9125825EL16XC1S036-230B TXV 33,800 16 13 CH23-51 SL280UH090V36B 9125826EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 SL280UH090V48B 9125827EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 SL280UH090XV48B 9125828EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 SL280UH110V60C 9125829EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 SL280UH110XV60C 9125830NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 99: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 99

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 SLP98UH070XV36B 9125831EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 SLP98UH090XV36C 9125832EL16XC1S036-230B TXV 33,600 15.5 12.5 CH23-51 SLP98UH090XV48C 9125833EL16XC1S036-230B TXV 34,200 15.5 12.5 CH23-51 SLP98UH110XV60C 9125834EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-31A EL180UH045E36A 9125835EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-31A EL180UH045XE36A 9125836EL16XC1S036-230B TXV 34,600 15.1 12.5 CH33-31A SL280UH070V36A 9125837EL16XC1S036-230B TXV 34,600 15.1 12.5 CH33-31A SL280UH070XV36A 9125838EL16XC1S036-230B TXV 34,600 16 13 CH33-31B EL180UH070E36B 9125839EL16XC1S036-230B TXV 34,600 16 13 CH33-31B EL180UH070XE36B 9125840EL16XC1S036-230B TXV 34,800 16 13 CH33-31B EL180UH090E48B 9125841EL16XC1S036-230B TXV 34,800 16 13 CH33-31B EL180UH090XE48B 9125842EL16XC1S036-230B TXV 34,600 15.1 12.2 CH33-31B EL195UH045XE36B 9125843EL16XC1S036-230B TXV 34,600 15.5 12.5 CH33-31B EL195UH070XE36B 9125844EL16XC1S036-230B TXV 34,600 15.1 12.2 CH33-31B EL296UH045XE36B 9125845EL16XC1S036-230B TXV 34,800 15.5 12.5 CH33-31B EL296UH045XV36B 9125846EL16XC1S036-230B TXV 34,600 15.5 12.5 CH33-31B EL296UH070XE36B 9125847EL16XC1S036-230B TXV 34,800 15.5 12.5 CH33-31B EL296UH070XV36B 9125848EL16XC1S036-230B TXV 35,000 16 13 CH33-31B SL280UH090V36B 9125849EL16XC1S036-230B TXV 35,000 16 13 CH33-31B SL280UH090V48B 9125850EL16XC1S036-230B TXV 35,000 16 13 CH33-31B SL280UH090XV48B 9125851EL16XC1S036-230B TXV 34,800 15.5 12.5 CH33-31B SLP98UH070XV36B 9125852EL16XC1S036-230B TXV 34,400 14.5 12.2 CH33-31B 9125854EL16XC1S036-230B TXV 33,400 14.5 12.2 CH33-36A EL180UH045E36A 9125855EL16XC1S036-230B TXV 33,400 14.5 12.2 CH33-36A EL180UH045XE36A 9125856EL16XC1S036-230B TXV 33,200 14.5 12 CH33-36A SL280UH070V36A 9126445EL16XC1S036-230B TXV 33,200 14.5 12 CH33-36A SL280UH070XV36A 9126446EL16XC1S036-230B TXV 33,400 15.5 12.5 CH33-36B EL180UH070E36B 9125857EL16XC1S036-230B TXV 33,400 15.5 12.5 CH33-36B EL180UH070XE36B 9125858EL16XC1S036-230B TXV 33,600 15.5 12.5 CH33-36B EL180UH090E48B 9125859EL16XC1S036-230B TXV 33,600 15.5 12.5 CH33-36B EL180UH090XE48B 9125860EL16XC1S036-230B TXV 33,000 14.5 12.2 CH33-36B EL195UH045XE36B 9125861EL16XC1S036-230B TXV 33,200 15.1 12.5 CH33-36B EL195UH070XE36B 9125862EL16XC1S036-230B TXV 33,000 14.5 12.2 CH33-36B EL296UH045XE36B 9125863EL16XC1S036-230B TXV 33,400 14.5 12.2 CH33-36B EL296UH045XV36B 9125864EL16XC1S036-230B TXV 33,200 15.1 12.5 CH33-36B EL296UH070XE36B 9125865EL16XC1S036-230B TXV 33,200 15.1 12.5 CH33-36B EL296UH070XV36B 9125866EL16XC1S036-230B TXV 33,400 15.5 12.5 CH33-36B SL280UH090V36B 9125867EL16XC1S036-230B TXV 33,600 15.5 12.5 CH33-36B SL280UH090V48B 9125868EL16XC1S036-230B TXV 33,600 15.5 12.5 CH33-36B SL280UH090XV48B 9125869EL16XC1S036-230B TXV 33,200 15.1 12.5 CH33-36B SLP98UH070XV36B 9125870EL16XC1S036-230B TXV 34,200 16 13 CH33-36C EL180UH090E60C 9125871EL16XC1S036-230B TXV 34,000 16 13 CH33-36C EL180UH110E60C 9125872EL16XC1S036-230B TXV 34,000 16 13 CH33-36C EL180UH110XE60C 9125873EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL195UH090XE48C 9125874EL16XC1S036-230B TXV 34,200 15.5 12.5 CH33-36C EL195UH110XE60C 9125875EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL296UH090XE48C 9125876EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL296UH090XV36C 9125877EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL296UH090XV48C 9125878NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 100: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 100

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,200 15.5 12.5 CH33-36C EL296UH110XE60C 9125879EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL296UH110XV48C 9125880EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-36C EL296UH110XV60C 9125881EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-36C SL280UH110V60C 9125882EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-36C SL280UH110XV60C 9125883EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C SLP98UH090XV36C 9125884EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C SLP98UH090XV48C 9125885EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-36C SLP98UH110XV60C 9125886EL16XC1S036-230B TXV 34,200 16 13 CH33-42B EL180UH070E36B 9125887EL16XC1S036-230B TXV 34,200 16 13 CH33-42B EL180UH070XE36B 9125888EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-42B EL180UH090E48B 9125889EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-42B EL180UH090XE48B 9125890EL16XC1S036-230B TXV 34,200 14.5 12.2 CH33-42B EL195UH045XE36B 9125891EL16XC1S036-230B TXV 34,000 15.1 12.5 CH33-42B EL195UH070XE36B 9125892EL16XC1S036-230B TXV 34,200 14.5 12.2 CH33-42B EL296UH045XE36B 9125893EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-42B EL296UH045XV36B 9125894EL16XC1S036-230B TXV 34,000 15.1 12.5 CH33-42B EL296UH070XE36B 9125895EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-42B EL296UH070XV36B 9125896EL16XC1S036-230B TXV 34,600 16 13 CH33-42B SL280UH090V36B 9125897EL16XC1S036-230B TXV 34,600 15.5 12.5 CH33-42B SL280UH090V48B 9125898EL16XC1S036-230B TXV 34,600 15.5 12.5 CH33-42B SL280UH090XV48B 9125899EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-42B SLP98UH070XV36B 9125900EL16XC1S036-230B TXV 35,600 16 13 CH33-43B EL180UH070E36B 9125901EL16XC1S036-230B TXV 35,600 16 13 CH33-43B EL180UH070XE36B 9125902EL16XC1S036-230B TXV 35,800 16 13 CH33-43B EL180UH090E48B 9125903EL16XC1S036-230B TXV 35,800 16 13 CH33-43B EL180UH090XE48B 9125904EL16XC1S036-230B TXV 35,600 15.5 12.5 CH33-43B EL195UH045XE36B 9125905EL16XC1S036-230B TXV 35,400 16 13 CH33-43B EL195UH070XE36B 9125906EL16XC1S036-230B TXV 35,600 15.5 12.5 CH33-43B EL296UH045XE36B 9125907EL16XC1S036-230B TXV 35,800 16 13 CH33-43B EL296UH045XV36B 9125908EL16XC1S036-230B TXV 35,400 16 13 CH33-43B EL296UH070XE36B 9125909EL16XC1S036-230B TXV 35,800 16 13 CH33-43B EL296UH070XV36B 9125910EL16XC1S036-230B TXV 36,000 16 13 CH33-43B SL280UH090V36B 9125911EL16XC1S036-230B TXV 36,000 16 13 CH33-43B SL280UH090V48B 9125912EL16XC1S036-230B TXV 36,000 16 13 CH33-43B SL280UH090XV48B 9125913EL16XC1S036-230B TXV 35,800 16 13 CH33-43B SLP98UH070XV36B 9125914EL16XC1S036-230B TXV 35,400 15.1 12.5 CH33-43B 9125916EL16XC1S036-230B TXV 35,600 16 13 CH33-43C EL180UH090E60C 9125917EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL180UH110E60C 9125918EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL180UH110XE60C 9125919EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL195UH090XE48C 9125920EL16XC1S036-230B TXV 35,600 16 13 CH33-43C EL195UH110XE60C 9125921EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL296UH090XE48C 9125922EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL296UH090XV36C 9125923EL16XC1S036-230B TXV 35,200 16 13 CH33-43C EL296UH090XV48C 9125924EL16XC1S036-230B TXV 35,600 16 13 CH33-43C EL296UH110XE60C 9125925EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL296UH110XV48C 9125926EL16XC1S036-230B TXV 35,800 16 13 CH33-43C EL296UH110XV60C 9125927EL16XC1S036-230B TXV 35,800 16 13 CH33-43C SL280UH090V60C 9125928NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 101: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 101

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,800 16 13 CH33-43C SL280UH090XV60C 9125929EL16XC1S036-230B TXV 35,600 16 13 CH33-43C SL280UH110V60C 9125930EL16XC1S036-230B TXV 35,600 16 13 CH33-43C SL280UH110XV60C 9125931EL16XC1S036-230B TXV 35,400 16 13 CH33-43C SLP98UH090XV36C 9125932EL16XC1S036-230B TXV 35,200 16 13 CH33-43C SLP98UH090XV48C 9125933EL16XC1S036-230B TXV 35,800 16 13 CH33-43C SLP98UH110XV60C 9125934EL16XC1S036-230B TXV 34,600 16 13 CH33-44/48B EL180UH070E36B 9125935EL16XC1S036-230B TXV 34,600 16 13 CH33-44/48B EL180UH070XE36B 9125936EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B EL180UH090E48B 9125937EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B EL180UH090XE48B 9125938EL16XC1S036-230B TXV 34,800 15.1 12.5 CH33-44/48B EL195UH045XE36B 9125939EL16XC1S036-230B TXV 34,800 15.1 12.5 CH33-44/48B EL195UH070XE36B 9125940EL16XC1S036-230B TXV 34,800 15.1 12.5 CH33-44/48B EL296UH045XE36B 9125941EL16XC1S036-230B TXV 34,800 15.5 12.5 CH33-44/48B EL296UH045XV36B 9125942EL16XC1S036-230B TXV 34,800 15.1 12.5 CH33-44/48B EL296UH070XE36B 9125943EL16XC1S036-230B TXV 35,000 15.5 12.5 CH33-44/48B EL296UH070XV36B 9125944EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B SL280UH090V36B 9125945EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B SL280UH090V48B 9125946EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B SL280UH090XV48B 9125947EL16XC1S036-230B TXV 35,000 15.5 12.5 CH33-44/48B SLP98UH070XV36B 9125948EL16XC1S036-230B TXV 34,600 14.5 12.2 CH33-44/48B 9125950EL16XC1S036-230B TXV 35,400 16 13 CH33-48C EL180UH090E60C 9125951EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL180UH110E60C 9125952EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL180UH110XE60C 9125953EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL195UH090XE48C 9125954EL16XC1S036-230B TXV 35,400 16 13 CH33-48C EL195UH110XE60C 9125955EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL296UH090XE48C 9125956EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL296UH090XV36C 9125957EL16XC1S036-230B TXV 35,000 16 13 CH33-48C EL296UH090XV48C 9125958EL16XC1S036-230B TXV 35,400 16 13 CH33-48C EL296UH110XE60C 9125959EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL296UH110XV48C 9125960EL16XC1S036-230B TXV 35,600 16 13 CH33-48C EL296UH110XV60C 9125961EL16XC1S036-230B TXV 35,600 16 13 CH33-48C SL280UH090V60C 9125962EL16XC1S036-230B TXV 35,600 16 13 CH33-48C SL280UH090XV60C 9125963EL16XC1S036-230B TXV 35,400 16 13 CH33-48C SL280UH110V60C 9125964EL16XC1S036-230B TXV 35,400 16 13 CH33-48C SL280UH110XV60C 9125965EL16XC1S036-230B TXV 35,200 16 13 CH33-48C SLP98UH090XV36C 9125966EL16XC1S036-230B TXV 35,000 16 13 CH33-48C SLP98UH090XV48C 9125967EL16XC1S036-230B TXV 35,600 16 13 CH33-48C SLP98UH110XV60C 9125968EL16XC1S036-230B TXV 34,600 14.5 12.2 CH33-48C 9125970EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL180UH090E60C 9125971EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL180UH110E60C 9125972EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL180UH110XE60C 9125973EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL195UH090XE48C 9125974EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL195UH110XE60C 9125975EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL296UH090XE48C 9125976EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL296UH090XV36C 9125977EL16XC1S036-230B TXV 35,600 16 13 CH33-49 EL296UH090XV48C 9125978EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL296UH110XE60C 9125979NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 102: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 102

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL296UH110XV48C 9125980EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL296UH110XV60C 9125981EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SL280UH090V60C 9125982EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SL280UH090XV60C 9125983EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SL280UH110V60C 9125984EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SL280UH110XV60C 9125985EL16XC1S036-230B TXV 35,800 16 13 CH33-49 SLP98UH090XV36C 9125986EL16XC1S036-230B TXV 35,600 16 13 CH33-49 SLP98UH090XV48C 9125987EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SLP98UH110XV60C 9125988EL16XC1S036-230B TXV 35,200 15.1 12.2 CH33-49 9125990EL16XC1S036-230B TXV 35,800 16 13 CH33-50/60C EL180UH090E60C 9125991EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL180UH110E60C 9125992EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL180UH110XE60C 9125993EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL195UH090XE48C 9125994EL16XC1S036-230B TXV 35,800 16 13 CH33-50/60C EL195UH110XE60C 9125995EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL296UH090XE48C 9125996EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL296UH090XV36C 9125997EL16XC1S036-230B TXV 35,400 16 13 CH33-50/60C EL296UH090XV48C 9125998EL16XC1S036-230B TXV 35,800 16 13 CH33-50/60C EL296UH110XE60C 9125999EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL296UH110XV48C 9126000EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C EL296UH110XV60C 9126001EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SL280UH090V60C 9126002EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SL280UH090XV60C 9126003EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SL280UH110V60C 9126004EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SL280UH110XV60C 9126005EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C SLP98UH090XV36C 9126006EL16XC1S036-230B TXV 35,400 16 13 CH33-50/60C SLP98UH090XV48C 9126007EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SLP98UH110XV60C 9126008EL16XC1S036-230B TXV 35,000 14.5 12.2 CH33-50/60C 9126010EL16XC1S036-230B TXV 34,600 15.1 12.5 CH35-30A EL180UH045E36A 9126011EL16XC1S036-230B TXV 34,600 15.1 12.5 CH35-30A EL180UH045XE36A 9126012EL16XC1S036-230B TXV 34,600 15.1 12.5 CH35-30A SL280UH070V36A 9126013EL16XC1S036-230B TXV 34,600 15.1 12.5 CH35-30A SL280UH070XV36A 9126014EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-30B EL180UH070E36B 9126015EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-30B EL180UH070XE36B 9126016EL16XC1S036-230B TXV 35,000 16 13 CH35-30B EL180UH090E48B 9126017EL16XC1S036-230B TXV 35,000 16 13 CH35-30B EL180UH090XE48B 9126018EL16XC1S036-230B TXV 34,800 15.1 12.5 CH35-30B EL195UH045XE36B 9126019EL16XC1S036-230B TXV 34,800 15.1 12.5 CH35-30B EL195UH070XE36B 9126020EL16XC1S036-230B TXV 34,800 15.1 12.5 CH35-30B EL296UH045XE36B 9126021EL16XC1S036-230B TXV 35,000 15.5 12.5 CH35-30B EL296UH045XV36B 9126022EL16XC1S036-230B TXV 34,800 15.1 12.5 CH35-30B EL296UH070XE36B 9126023EL16XC1S036-230B TXV 35,000 15.5 12.5 CH35-30B EL296UH070XV36B 9126024EL16XC1S036-230B TXV 35,200 16 13 CH35-30B SL280UH090V36B 9126025EL16XC1S036-230B TXV 35,200 16 13 CH35-30B SL280UH090V48B 9126026EL16XC1S036-230B TXV 35,200 16 13 CH35-30B SL280UH090XV48B 9126027EL16XC1S036-230B TXV 35,000 15.5 12.5 CH35-30B SLP98UH070XV36B 9126028EL16XC1S036-230B TXV 34,600 14.5 12.2 CH35-30B 9126029EL16XC1S036-230B TXV 33,200 14.5 12.2 CH35-36A EL180UH045E36A 9126030NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 103: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 103

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,200 14.5 12.2 CH35-36A EL180UH045XE36A 9126031EL16XC1S036-230B TXV 33,400 14.5 12.2 CH35-36A SL280UH070V36A 9126032EL16XC1S036-230B TXV 33,400 14.5 12.2 CH35-36A SL280UH070XV36A 9126033EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B EL180UH070E36B 9126034EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B EL180UH070XE36B 9126035EL16XC1S036-230B TXV 33,600 15.1 12.5 CH35-36B EL180UH090E48B 9126036EL16XC1S036-230B TXV 33,600 15.1 12.5 CH35-36B EL180UH090XE48B 9126037EL16XC1S036-230B TXV 33,000 15.1 12.2 CH35-36B EL195UH045XE36B 9126038EL16XC1S036-230B TXV 33,200 14.5 12 CH35-36B EL195UH070XE36B 9126447EL16XC1S036-230B TXV 33,000 15.1 12.2 CH35-36B EL296UH045XE36B 9126039EL16XC1S036-230B TXV 33,200 15.1 12.2 CH35-36B EL296UH045XV36B 9126040EL16XC1S036-230B TXV 33,200 14.5 12 CH35-36B EL296UH070XE36B 9126448EL16XC1S036-230B TXV 33,200 15.1 12.5 CH35-36B EL296UH070XV36B 9126041EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B SL280UH090V36B 9126042EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B SL280UH090V48B 9126043EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B SL280UH090XV48B 9126044EL16XC1S036-230B TXV 33,200 15.1 12.5 CH35-36B SLP98UH070XV36B 9126045EL16XC1S036-230B TXV 34,400 16 13 CH35-36C EL180UH090E60C 9126046EL16XC1S036-230B TXV 34,200 16 13 CH35-36C EL180UH110E60C 9126047EL16XC1S036-230B TXV 34,200 16 13 CH35-36C EL180UH110XE60C 9126048EL16XC1S036-230B TXV 34,200 15.5 12.5 CH35-36C EL195UH090XE48C 9126049EL16XC1S036-230B TXV 34,400 15.5 12.5 CH35-36C EL195UH110XE60C 9126050EL16XC1S036-230B TXV 34,200 15.5 12.5 CH35-36C EL296UH090XE48C 9126051EL16XC1S036-230B TXV 34,200 15.5 12.5 CH35-36C EL296UH090XV36C 9126052EL16XC1S036-230B TXV 34,000 15.5 12.5 CH35-36C EL296UH090XV48C 9126053EL16XC1S036-230B TXV 34,400 15.5 12.5 CH35-36C EL296UH110XE60C 9126054EL16XC1S036-230B TXV 34,200 16 13 CH35-36C EL296UH110XV48C 9126055EL16XC1S036-230B TXV 34,400 16 13 CH35-36C EL296UH110XV60C 9126056EL16XC1S036-230B TXV 34,600 16 13 CH35-36C SL280UH090V60C 9126057EL16XC1S036-230B TXV 34,600 16 13 CH35-36C SL280UH090XV60C 9126058EL16XC1S036-230B TXV 34,400 15.5 12.5 CH35-36C SL280UH110V60C 9126059EL16XC1S036-230B TXV 34,400 15.5 12.5 CH35-36C SL280UH110XV60C 9126060EL16XC1S036-230B TXV 34,200 15.5 12.5 CH35-36C SLP98UH090XV36C 9126061EL16XC1S036-230B TXV 34,000 15.5 12.5 CH35-36C SLP98UH090XV48C 9126062EL16XC1S036-230B TXV 34,400 16 13 CH35-36C SLP98UH110XV60C 9126063EL16XC1S036-230B TXV 36,000 16 13 CH35-42B EL180UH070E36B 9126064EL16XC1S036-230B TXV 36,000 16 13 CH35-42B EL180UH070XE36B 9126065EL16XC1S036-230B TXV 35,800 16 13 CH35-42B EL180UH090E48B 9126066EL16XC1S036-230B TXV 35,800 16 13 CH35-42B EL180UH090XE48B 9126067EL16XC1S036-230B TXV 35,600 15.5 12.5 CH35-42B EL195UH045XE36B 9126068EL16XC1S036-230B TXV 35,600 15.5 12.5 CH35-42B EL195UH070XE36B 9126069EL16XC1S036-230B TXV 35,600 15.5 12.5 CH35-42B EL296UH045XE36B 9126070EL16XC1S036-230B TXV 35,800 16 13 CH35-42B EL296UH045XV36B 9126071EL16XC1S036-230B TXV 35,600 15.5 12.5 CH35-42B EL296UH070XE36B 9126072EL16XC1S036-230B TXV 35,800 16 13 CH35-42B EL296UH070XV36B 9126073EL16XC1S036-230B TXV 36,000 16 13 CH35-42B SL280UH090V36B 9126074EL16XC1S036-230B TXV 36,000 16 13 CH35-42B SL280UH090V48B 9126075EL16XC1S036-230B TXV 36,000 16 13 CH35-42B SL280UH090XV48B 9126076EL16XC1S036-230B TXV 35,800 16 13 CH35-42B SLP98UH070XV36B 9126077NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 104: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 104

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,400 15.1 12.5 CH35-42B 9126078EL16XC1S036-230B TXV 35,800 16 13 CH35-42C EL180UH090E60C 9126079EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL180UH110E60C 9126080EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL180UH110XE60C 9126081EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL195UH090XE48C 9126082EL16XC1S036-230B TXV 35,600 16 13 CH35-42C EL195UH110XE60C 9126083EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL296UH090XE48C 9126084EL16XC1S036-230B TXV 35,600 16 13 CH35-42C EL296UH090XV36C 9126085EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL296UH090XV48C 9126086EL16XC1S036-230B TXV 35,600 16 13 CH35-42C EL296UH110XE60C 9126087EL16XC1S036-230B TXV 35,600 16 13 CH35-42C EL296UH110XV48C 9126088EL16XC1S036-230B TXV 35,800 16 13 CH35-42C EL296UH110XV60C 9126089EL16XC1S036-230B TXV 36,000 16 13 CH35-42C SL280UH090V60C 9126090EL16XC1S036-230B TXV 36,000 16 13 CH35-42C SL280UH090XV60C 9126091EL16XC1S036-230B TXV 35,800 16 13 CH35-42C SL280UH110V60C 9126092EL16XC1S036-230B TXV 35,800 16 13 CH35-42C SL280UH110XV60C 9126093EL16XC1S036-230B TXV 35,600 16 13 CH35-42C SLP98UH090XV36C 9126094EL16XC1S036-230B TXV 35,400 16 13 CH35-42C SLP98UH090XV48C 9126095EL16XC1S036-230B TXV 35,800 16 13 CH35-42C SLP98UH110XV60C 9126096EL16XC1S036-230B TXV 35,000 14.5 12.2 CH35-42C 9126097EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-48B EL180UH070E36B 9126098EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-48B EL180UH070XE36B 9126099EL16XC1S036-230B TXV 35,000 16 13 CH35-48B EL180UH090E48B 9126100EL16XC1S036-230B TXV 35,000 16 13 CH35-48B EL180UH090XE48B 9126101EL16XC1S036-230B TXV 35,000 15.1 12.5 CH35-48B EL195UH045XE36B 9126102EL16XC1S036-230B TXV 35,000 15.1 12.5 CH35-48B EL195UH070XE36B 9126103EL16XC1S036-230B TXV 35,000 15.1 12.5 CH35-48B EL296UH045XE36B 9126104EL16XC1S036-230B TXV 35,000 15.5 12.5 CH35-48B EL296UH045XV36B 9126105EL16XC1S036-230B TXV 35,000 15.1 12.5 CH35-48B EL296UH070XE36B 9126106EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-48B EL296UH070XV36B 9126107EL16XC1S036-230B TXV 35,200 16 13 CH35-48B SL280UH090V36B 9126108EL16XC1S036-230B TXV 35,200 16 13 CH35-48B SL280UH090V48B 9126109EL16XC1S036-230B TXV 35,200 16 13 CH35-48B SL280UH090XV48B 9126110EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-48B SLP98UH070XV36B 9126111EL16XC1S036-230B TXV 34,800 14.5 12.2 CH35-48B 9126112EL16XC1S036-230B TXV 35,600 16 13 CH35-48C EL180UH090E60C 9126113EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL180UH110E60C 9126114EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL180UH110XE60C 9126115EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL195UH090XE48C 9126116EL16XC1S036-230B TXV 35,600 16 13 CH35-48C EL195UH110XE60C 9126117EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL296UH090XE48C 9126118EL16XC1S036-230B TXV 35,400 16 13 CH35-48C EL296UH090XV36C 9126119EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL296UH090XV48C 9126120EL16XC1S036-230B TXV 35,600 16 13 CH35-48C EL296UH110XE60C 9126121EL16XC1S036-230B TXV 35,400 16 13 CH35-48C EL296UH110XV48C 9126122EL16XC1S036-230B TXV 35,600 16 13 CH35-48C EL296UH110XV60C 9126123EL16XC1S036-230B TXV 35,800 16 13 CH35-48C SL280UH090V60C 9126124EL16XC1S036-230B TXV 35,800 16 13 CH35-48C SL280UH090XV60C 9126125EL16XC1S036-230B TXV 35,600 16 13 CH35-48C SL280UH110V60C 9126126NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 105: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 105

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,600 16 13 CH35-48C SL280UH110XV60C 9126127EL16XC1S036-230B TXV 35,400 16 13 CH35-48C SLP98UH090XV36C 9126128EL16XC1S036-230B TXV 35,200 16 13 CH35-48C SLP98UH090XV48C 9126129EL16XC1S036-230B TXV 35,600 16 13 CH35-48C SLP98UH110XV60C 9126130EL16XC1S036-230B TXV 34,800 14.5 12.2 CH35-48C 9126131EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL180UH090E60C 9126132EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL180UH110E60C 9126133EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL180UH110XE60C 9126134EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL195UH090XE48C 9126135EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL195UH110XE60C 9126136EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL296UH090XE48C 9126137EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL296UH090XV36C 9126138EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL296UH090XV48C 9126139EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL296UH110XE60C 9126140EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL296UH110XV48C 9126141EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL296UH110XV60C 9126142EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SL280UH090V60C 9126143EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SL280UH090XV60C 9126144EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SL280UH110V60C 9126145EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SL280UH110XV60C 9126146EL16XC1S036-230B TXV 35,800 16 13 CH35-51C SLP98UH090XV36C 9126147EL16XC1S036-230B TXV 35,800 16 13 CH35-51C SLP98UH090XV48C 9126148EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SLP98UH110XV60C 9126149EL16XC1S036-230B TXV 35,200 15.1 12.2 CH35-51C 9126150EL16XC1S036-230B TXV 34,000 15.1 12.2 CR33-30/36A EL180DF045E36A 9126151EL16XC1S036-230B TXV 33,800 15.1 12.5 CR33-30/36A SL280DF070V36A 9126152EL16XC1S036-230B TXV 33,800 15.5 12.5 CR33-30/36B EL180DF070E36B 9126153EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36B EL180DF090E48B 9126154EL16XC1S036-230B TXV 33,800 14.5 12.2 CR33-30/36B EL195DF045XE36B 9126155EL16XC1S036-230B TXV 33,800 15.1 12.5 CR33-30/36B EL195DF070XE48B 9126156EL16XC1S036-230B TXV 33,800 14.5 12.2 CR33-30/36B EL296DF045XE36B 9126157EL16XC1S036-230B TXV 33,800 15.1 12.2 CR33-30/36B EL296DF045XV36B 9126158EL16XC1S036-230B TXV 33,800 15.1 12.5 CR33-30/36B EL296DF070XE48B 9126159EL16XC1S036-230B TXV 33,800 14.5 12.2 CR33-30/36B EL296DF070XV48B 9126160EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36B SL280DF090V48B 9126161EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-30/36B SLP98DF070XV36B 9126162EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL180DF110E60C 9126163EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL195DF090XE48C 9126164EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL195DF110XE60C 9126165EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL296DF090XE48C 9126166EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-30/36C EL296DF090XV60C 9126167EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL296DF110XE60C 9126168EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-30/36C EL296DF110XV60C 9126169EL16XC1S036-230B TXV 34,200 15.5 12.5 CR33-30/36C SL280DF110V60C 9126170EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-30/36C SLP98DF090XV36C 9126171EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-30/36C SLP98DF090XV48C 9126172EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-30/36C SLP98DF090XV60C 9126173EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-30/36C SLP98DF110XV60C 9126174EL16XC1S036-230B TXV 34,200 16 13 CR33-48B EL180DF070E36B 9126175NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 106: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 106

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,400 16 13 CR33-48B EL180DF090E48B 9126176EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-48B EL195DF045XE36B 9126177EL16XC1S036-230B TXV 34,200 15.5 12.5 CR33-48B EL195DF070XE48B 9126178EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-48B EL296DF045XE36B 9126179EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-48B EL296DF045XV36B 9126180EL16XC1S036-230B TXV 34,200 15.5 12.5 CR33-48B EL296DF070XE48B 9126181EL16XC1S036-230B TXV 34,400 15.1 12.5 CR33-48B EL296DF070XV48B 9126182EL16XC1S036-230B TXV 34,400 15.5 12.5 CR33-48B SL280DF090V48B 9126183EL16XC1S036-230B TXV 34,200 15.5 12.5 CR33-48B SLP98DF070XV36B 9126184EL16XC1S036-230B TXV 33,800 14.5 12 CR33-48B 10238959EL16XC1S036-230B TXV 34,800 16 13 CR33-48C EL180DF110E60C 9126185EL16XC1S036-230B TXV 34,600 16 13 CR33-48C EL195DF090XE48C 9126186EL16XC1S036-230B TXV 34,600 16 13 CR33-48C EL195DF110XE60C 9126187EL16XC1S036-230B TXV 34,600 16 13 CR33-48C EL296DF090XE48C 9126188EL16XC1S036-230B TXV 34,600 15.5 12.5 CR33-48C EL296DF090XV60C 9126189EL16XC1S036-230B TXV 34,600 16 13 CR33-48C EL296DF110XE60C 9126190EL16XC1S036-230B TXV 34,600 15.5 12.5 CR33-48C EL296DF110XV60C 9126191EL16XC1S036-230B TXV 34,600 16 13 CR33-48C SL280DF110V60C 9126192EL16XC1S036-230B TXV 34,400 15.5 12.5 CR33-48C SLP98DF090XV36C 9126193EL16XC1S036-230B TXV 34,200 16 13 CR33-48C SLP98DF090XV48C 9126194EL16XC1S036-230B TXV 34,600 15.5 12.5 CR33-48C SLP98DF090XV60C 9126195EL16XC1S036-230B TXV 34,600 15.5 12.5 CR33-48C SLP98DF110XV60C 9126196EL16XC1S036-230B TXV 33,800 14.5 12 CR33-48C 10238960EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-31A EL180UH045E36A 9126197EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-31A EL180UH045XE36A 9126198EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31A SL280UH070V36A 9126199EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31A SL280UH070XV36A 9126200EL16XC1S036-230B TXV 34,200 14.5 12 CX34-31A 9126449EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31B EL180UH070E36B 9126201EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31B EL180UH070XE36B 9126202EL16XC1S036-230B TXV 34,400 15.5 12.5 CX34-31B EL180UH090E48B 9126203EL16XC1S036-230B TXV 34,400 15.5 12.5 CX34-31B EL180UH090XE48B 9126204EL16XC1S036-230B TXV 34,400 14.5 12.2 CX34-31B EL195UH045XE36B 9126205EL16XC1S036-230B TXV 34,200 15.1 12.5 CX34-31B EL195UH070XE36B 9126206EL16XC1S036-230B TXV 34,400 14.5 12.2 CX34-31B EL296UH045XE36B 9126207EL16XC1S036-230B TXV 34,400 15.1 12.5 CX34-31B EL296UH045XV36B 9126208EL16XC1S036-230B TXV 34,200 15.1 12.5 CX34-31B EL296UH070XE36B 9126209EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31B EL296UH070XV36B 9126210EL16XC1S036-230B TXV 34,600 16 13 CX34-31B SL280UH090V36B 9126211EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-31B SL280UH090V48B 9126212EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-31B SL280UH090XV48B 9126213EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31B SLP98UH070XV36B 9126214EL16XC1S036-230B TXV 34,200 14.5 12 CX34-31B 9126450EL16XC1S036-230B TXV 33,600 14.5 12.2 CX34-36A EL180UH045E36A 9126215EL16XC1S036-230B TXV 33,600 14.5 12.2 CX34-36A EL180UH045XE36A 9126216EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-36A SL280UH070V36A 9126217EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-36A SL280UH070XV36A 9126218EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36B EL180UH070E36B 9126219EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36B EL180UH070XE36B 9126220NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 107: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 107

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36B EL180UH090E48B 9126221EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36B EL180UH090XE48B 9126222EL16XC1S036-230B TXV 33,000 15.1 12.2 CX34-36B EL195UH045XE36B 9126223EL16XC1S036-230B TXV 33,400 15.1 12.5 CX34-36B EL195UH070XE36B 9126224EL16XC1S036-230B TXV 33,000 15.1 12.2 CX34-36B EL296UH045XE36B 9126225EL16XC1S036-230B TXV 33,000 14.5 12.2 CX34-36B EL296UH045XV36B 9126226EL16XC1S036-230B TXV 33,400 15.1 12.5 CX34-36B EL296UH070XE36B 9126227EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-36B EL296UH070XV36B 9126228EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36B SL280UH090V36B 9126229EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36B SL280UH090V48B 9126230EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36B SL280UH090XV48B 9126231EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-36B SLP98UH070XV36B 9126232EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36C EL180UH090E60C 9126233EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36C EL180UH110E60C 9126234EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36C EL180UH110XE60C 9126235EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36C EL195UH090XE48C 9126236EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36C EL195UH110XE60C 9126237EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36C EL296UH090XE48C 9126238EL16XC1S036-230B TXV 33,600 15.1 12.5 CX34-36C EL296UH090XV36C 9126239EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36C EL296UH090XV48C 9126240EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36C EL296UH110XE60C 9126241EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36C EL296UH110XV48C 9126242EL16XC1S036-230B TXV 33,600 15.1 12.5 CX34-36C SLP98UH090XV36C 9126243EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36C SLP98UH090XV48C 9126244EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38A EL180UH045E36A 9126245EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38A EL180UH045XE36A 9126246EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38A SL280UH070V36A 9126247EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38A SL280UH070XV36A 9126248EL16XC1S036-230B TXV 34,600 14.5 12.2 CX34-38A 9126249EL16XC1S036-230B TXV 34,800 16 13 CX34-38B EL180UH070E36B 9126250EL16XC1S036-230B TXV 34,800 16 13 CX34-38B EL180UH070XE36B 9126251EL16XC1S036-230B TXV 35,200 16 13 CX34-38B EL180UH090E48B 9126252EL16XC1S036-230B TXV 35,200 16 13 CX34-38B EL180UH090XE48B 9126253EL16XC1S036-230B TXV 34,800 15.1 12.5 CX34-38B EL195UH045XE36B 9126254EL16XC1S036-230B TXV 34,800 15.5 12.5 CX34-38B EL195UH070XE36B 9126255EL16XC1S036-230B TXV 34,800 15.1 12.5 CX34-38B EL296UH045XE36B 9126256EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38B EL296UH045XV36B 9126257EL16XC1S036-230B TXV 34,800 15.5 12.5 CX34-38B EL296UH070XE36B 9126258EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38B EL296UH070XV36B 9126259EL16XC1S036-230B TXV 35,000 16 13 CX34-38B SL280UH090V36B 9126260EL16XC1S036-230B TXV 35,200 16 13 CX34-38B SL280UH090V48B 9126261EL16XC1S036-230B TXV 35,200 16 13 CX34-38B SL280UH090XV48B 9126262EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38B SLP98UH070XV36B 9126263EL16XC1S036-230B TXV 34,600 14.5 12.2 CX34-38B 9126264EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-42 EL180UH070E36B 9126265EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-42 EL180UH070XE36B 9126266EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-42 EL180UH090E48B 9126267EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-42 EL180UH090XE48B 9126268EL16XC1S036-230B TXV 33,000 15.1 12.2 CX34-42 EL195UH045XE36B 9126269NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 108: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 108

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,400 15.1 12.5 CX34-42 EL195UH070XE36B 9126270EL16XC1S036-230B TXV 33,000 15.1 12.2 CX34-42 EL296UH045XE36B 9126271EL16XC1S036-230B TXV 33,400 14.5 12.2 CX34-42 EL296UH045XV36B 9126272EL16XC1S036-230B TXV 33,400 15.1 12.5 CX34-42 EL296UH070XE36B 9126273EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-42 EL296UH070XV36B 9126274EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-42 SL280UH090V36B 9126275EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-42 SL280UH090V48B 9126276EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-42 SL280UH090XV48B 9126277EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-42 SLP98UH070XV36B 9126278EL16XC1S036-230B TXV 35,200 16 13 CX34-43B EL180UH070E36B 9126279EL16XC1S036-230B TXV 35,200 16 13 CX34-43B EL180UH070XE36B 9126280EL16XC1S036-230B TXV 35,600 16 13 CX34-43B EL180UH090E48B 9126281EL16XC1S036-230B TXV 35,600 16 13 CX34-43B EL180UH090XE48B 9126282EL16XC1S036-230B TXV 35,000 15.1 12.5 CX34-43B EL195UH045XE36B 9126283EL16XC1S036-230B TXV 35,000 16 13 CX34-43B EL195UH070XE36B 9126284EL16XC1S036-230B TXV 35,000 15.1 12.5 CX34-43B EL296UH045XE36B 9126285EL16XC1S036-230B TXV 35,200 15.5 12.5 CX34-43B EL296UH045XV36B 9126286EL16XC1S036-230B TXV 35,000 16 13 CX34-43B EL296UH070XE36B 9126287EL16XC1S036-230B TXV 35,200 15.5 12.5 CX34-43B EL296UH070XV36B 9126288EL16XC1S036-230B TXV 35,200 16 13 CX34-43B SL280UH090V36B 9126289EL16XC1S036-230B TXV 35,400 16 13 CX34-43B SL280UH090V48B 9126290EL16XC1S036-230B TXV 35,400 16 13 CX34-43B SL280UH090XV48B 9126291EL16XC1S036-230B TXV 35,200 15.5 12.5 CX34-43B SLP98UH070XV36B 9126292EL16XC1S036-230B TXV 34,800 14.5 12.2 CX34-43B 9126293EL16XC1S036-230B TXV 35,600 16 13 CX34-43C EL180UH090E60C 9126294EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL180UH110E60C 9126295EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL180UH110XE60C 9126296EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL195UH090XE48C 9126297EL16XC1S036-230B TXV 35,600 16 13 CX34-43C EL195UH110XE60C 9126298EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL296UH090XE48C 9126299EL16XC1S036-230B TXV 35,400 16 13 CX34-43C EL296UH090XV36C 9126300EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL296UH090XV48C 9126301EL16XC1S036-230B TXV 35,600 16 13 CX34-43C EL296UH110XE60C 9126302EL16XC1S036-230B TXV 35,400 16 13 CX34-43C EL296UH110XV48C 9126303EL16XC1S036-230B TXV 35,600 16 13 CX34-43C EL296UH110XV60C 9126304EL16XC1S036-230B TXV 35,800 16 13 CX34-43C SL280UH090V60C 9126305EL16XC1S036-230B TXV 35,800 16 13 CX34-43C SL280UH090XV60C 9126306EL16XC1S036-230B TXV 35,600 16 13 CX34-43C SL280UH110V60C 9126307EL16XC1S036-230B TXV 35,600 16 13 CX34-43C SL280UH110XV60C 9126308EL16XC1S036-230B TXV 35,400 16 13 CX34-43C SLP98UH090XV36C 9126309EL16XC1S036-230B TXV 35,200 16 13 CX34-43C SLP98UH090XV48C 9126310EL16XC1S036-230B TXV 35,600 16 13 CX34-43C SLP98UH110XV60C 9126311EL16XC1S036-230B TXV 34,800 14.5 12.2 CX34-43C 9126312EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48B EL180UH070E36B 9126313EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48B EL180UH070XE36B 9126314EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48B EL180UH090E48B 9126315EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48B EL180UH090XE48B 9126316EL16XC1S036-230B TXV 34,200 15.5 12.5 CX34-44/48B EL195UH045XE36B 9126317EL16XC1S036-230B TXV 34,400 15.5 12.5 CX34-44/48B EL195UH070XE36B 9126318NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 109: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 109

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,200 15.5 12.5 CX34-44/48B EL296UH045XE36B 9126319EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-44/48B EL296UH045XV36B 9126320EL16XC1S036-230B TXV 34,400 15.5 12.5 CX34-44/48B EL296UH070XE36B 9126321EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-44/48B EL296UH070XV36B 9126322EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48B SL280UH090V36B 9126323EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48B SL280UH090V48B 9126324EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48B SL280UH090XV48B 9126325EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-44/48B SLP98UH070XV36B 9126326EL16XC1S036-230B TXV 34,200 14.5 12 CX34-44/48B 9126451EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C EL180UH090E60C 9126327EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL180UH110E60C 9126328EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL180UH110XE60C 9126329EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL195UH090XE48C 9126330EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C EL195UH110XE60C 9126331EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL296UH090XE48C 9126332EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48C EL296UH090XV36C 9126333EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL296UH090XV48C 9126334EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C EL296UH110XE60C 9126335EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48C EL296UH110XV48C 9126336EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C EL296UH110XV60C 9126337EL16XC1S036-230B TXV 35,200 16 13 CX34-44/48C SL280UH090V60C 9126338EL16XC1S036-230B TXV 35,200 16 13 CX34-44/48C SL280UH090XV60C 9126339EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C SL280UH110V60C 9126340EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C SL280UH110XV60C 9126341EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48C SLP98UH090XV36C 9126342EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C SLP98UH090XV48C 9126343EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C SLP98UH110XV60C 9126344EL16XC1S036-230B TXV 34,200 14.5 12 CX34-44/48C 9126452EL16XC1S036-230B TXV 35,800 16 13 CX34-49 EL180UH090E60C 9126345EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL180UH110E60C 9126346EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL180UH110XE60C 9126347EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL195UH090XE48C 9126348EL16XC1S036-230B TXV 36,000 16 13 CX34-49 EL195UH110XE60C 9126349EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL296UH090XE48C 9126350EL16XC1S036-230B TXV 35,800 16 13 CX34-49 EL296UH090XV36C 9126351EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL296UH090XV48C 9126352EL16XC1S036-230B TXV 36,000 16 13 CX34-49 EL296UH110XE60C 9126353EL16XC1S036-230B TXV 35,800 16 13 CX34-49 EL296UH110XV48C 9126354EL16XC1S036-230B TXV 36,000 16 13 CX34-49 EL296UH110XV60C 9126355EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SL280UH090V60C 9126356EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SL280UH090XV60C 9126357EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SL280UH110V60C 9126358EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SL280UH110XV60C 9126359EL16XC1S036-230B TXV 35,800 16 13 CX34-49 SLP98UH090XV36C 9126360EL16XC1S036-230B TXV 35,600 16 13 CX34-49 SLP98UH090XV48C 9126361EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SLP98UH110XV60C 9126362EL16XC1S036-230B TXV 35,200 14.5 12.2 CX34-49 9126363EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C EL180UH090E60C 9126364EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL180UH110E60C 9126365NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 110: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 110

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL180UH110XE60C 9126366EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL195UH090XE48C 9126367EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C EL195UH110XE60C 9126368EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL296UH090XE48C 9126369EL16XC1S036-230B TXV 35,200 16 13 CX34-50/60C EL296UH090XV36C 9126370EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL296UH090XV48C 9126371EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C EL296UH110XE60C 9126372EL16XC1S036-230B TXV 35,200 16 13 CX34-50/60C EL296UH110XV48C 9126373EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C EL296UH110XV60C 9126374EL16XC1S036-230B TXV 35,600 16 13 CX34-50/60C SL280UH090V60C 9126375EL16XC1S036-230B TXV 35,600 16 13 CX34-50/60C SL280UH090XV60C 9126376EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C SL280UH110V60C 9126377EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C SL280UH110XV60C 9126378EL16XC1S036-230B TXV 35,200 16 13 CX34-50/60C SLP98UH090XV36C 9126379EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C SLP98UH090XV48C 9126380EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C SLP98UH110XV60C 9126381EL16XC1S036-230B TXV 34,600 14.5 12.2 CX34-50/60C 9126382EL16XC1S036-230B TXV 33,600 15.1 12.2 CX35-30/36A EL180UH045E36A 9126383EL16XC1S036-230B TXV 33,600 15.1 12.2 CX35-30/36A EL180UH045XE36A 9126384EL16XC1S036-230B TXV 33,400 15.1 12.5 CX35-30/36A SL280UH070V36A 9126385EL16XC1S036-230B TXV 33,400 15.1 12.5 CX35-30/36A SL280UH070XV36A 9126386EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36B EL180UH070E36B 9126387EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36B EL180UH070XE36B 9126388EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36B EL180UH090E48B 9126389EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36B EL180UH090XE48B 9126390EL16XC1S036-230B TXV 33,200 15.1 12.5 CX35-30/36B EL195UH045XE36B 9126391EL16XC1S036-230B TXV 33,200 15.1 12.5 CX35-30/36B EL296UH045XE36B 9126392EL16XC1S036-230B TXV 33,200 15.1 12.2 CX35-30/36B EL296UH045XV36B 9126393EL16XC1S036-230B TXV 33,400 15.1 12.5 CX35-30/36B EL296UH070XV36B 9126394EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36B SL280UH090V36B 9126395EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36B SL280UH090V48B 9126396EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36B SL280UH090XV48B 9126397EL16XC1S036-230B TXV 33,400 15.1 12.5 CX35-30/36B SLP98UH070XV36B 9126398EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36C EL180UH090E60C 9126399EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL180UH110E60C 9126400EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL180UH110XE60C 9126401EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL195UH090XE48C 9126402EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36C EL195UH110XE60C 9126403EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL296UH090XE48C 9126404EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36C EL296UH090XV36C 9126405EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL296UH090XV48C 9126406EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36C EL296UH110XE60C 9126407EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36C EL296UH110XV48C 9126408EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36C SLP98UH090XV36C 9126409EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C SLP98UH090XV48C 9126410EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36C SLP98UH110XV60C 9126411EL16XC1S036-230B TXV 34,800 15.5 12.5 CX35-30A EL180UH045E36A 9126412EL16XC1S036-230B TXV 34,800 15.5 12.5 CX35-30A EL180UH045XE36A 9126413EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30A SL280UH070V36A 9126414NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 111: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 111

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30A SL280UH070XV36A 9126415EL16XC1S036-230B TXV 34,400 16 13 CX35-30B EL180UH070E36B 9126416EL16XC1S036-230B TXV 34,400 16 13 CX35-30B EL180UH070XE36B 9126417EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30B EL180UH090E48B 9126418EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30B EL180UH090XE48B 9126419EL16XC1S036-230B TXV 34,400 14.5 12.2 CX35-30B EL195UH045XE36B 9126420EL16XC1S036-230B TXV 34,400 15.5 12.5 CX35-30B EL195UH070XE36B 9126421EL16XC1S036-230B TXV 34,400 14.5 12.2 CX35-30B EL296UH045XE36B 9126422EL16XC1S036-230B TXV 34,600 15.1 12.5 CX35-30B EL296UH045XV36B 9126423EL16XC1S036-230B TXV 34,400 15.5 12.5 CX35-30B EL296UH070XE36B 9126424EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30B EL296UH070XV36B 9126425EL16XC1S036-230B TXV 34,800 16 13 CX35-30B SL280UH090V36B 9126426EL16XC1S036-230B TXV 34,800 16 13 CX35-30B SL280UH090V48B 9126427EL16XC1S036-230B TXV 34,800 16 13 CX35-30B SL280UH090XV48B 9126428EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30B SLP98UH070XV36B 9126429EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-36A EL180UH045E36A 9126430EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-36A EL180UH045XE36A 9126431EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36A SL280UH070V36A 9126432EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36A SL280UH070XV36A 9126433EL16XC1S036-230B TXV 34,600 14.5 12.2 CX35-36A 9126434EL16XC1S036-230B TXV 35,000 16 13 CX35-36B EL180UH070E36B 9126435EL16XC1S036-230B TXV 35,000 16 13 CX35-36B EL180UH070XE36B 9126436EL16XC1S036-230B TXV 35,400 16 13 CX35-36B EL180UH090E48B 9126437EL16XC1S036-230B TXV 35,400 16 13 CX35-36B EL180UH090XE48B 9126438EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-36B EL195UH045XE36B 10150019EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B EL195UH070XE36B 10150020EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-36B EL296UH045XE36B 10150021EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B EL296UH045XV36B 10150022EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B EL296UH070XE36B 10150023EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B EL296UH070XV36B 10150024EL16XC1S036-230B TXV 35,200 16 13 CX35-36B SL280UH090V36B 10150025EL16XC1S036-230B TXV 35,200 16 13 CX35-36B SL280UH090V48B 10150026EL16XC1S036-230B TXV 35,200 16 13 CX35-36B SL280UH090XV48B 10150027EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B SLP98UH070XV36B 10150028EL16XC1S036-230B TXV 34,600 14.5 12.2 CX35-36B 10298951EL16XC1S036-230B TXV 35,200 16 13 CX35-48B EL180UH070E36B 10150030EL16XC1S036-230B TXV 35,200 16 13 CX35-48B EL180UH070XE36B 10150031EL16XC1S036-230B TXV 35,600 16 13 CX35-48B EL180UH090E48B 10150032EL16XC1S036-230B TXV 35,600 16 13 CX35-48B EL180UH090XE48B 10150033EL16XC1S036-230B TXV 34,800 15.5 12.5 CX35-48B EL195UH045XE36B 10150034EL16XC1S036-230B TXV 35,200 16 13 CX35-48B EL195UH070XE36B 10150035EL16XC1S036-230B TXV 34,800 15.5 12.5 CX35-48B EL296UH045XE36B 10150036EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-48B EL296UH045XV36B 10150037EL16XC1S036-230B TXV 35,200 16 13 CX35-48B EL296UH070XE36B 10150038EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-48B EL296UH070XV36B 10150039EL16XC1S036-230B TXV 35,400 16 13 CX35-48B SL280UH090V36B 10150040EL16XC1S036-230B TXV 35,400 16 13 CX35-48B SL280UH090V48B 10150041EL16XC1S036-230B TXV 35,400 16 13 CX35-48B SL280UH090XV48B 10150042EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-48B SLP98UH070XV36B 10150043NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 112: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 112

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,800 14.5 12.2 CX35-48B 10150029EL16XC1S036-230B TXV 35,600 16 13 CX35-48C EL180UH090E60C 10150045EL16XC1S036-230B TXV 35,200 16 13 CX35-48C EL180UH110E60C 10150046EL16XC1S036-230B TXV 35,200 16 13 CX35-48C EL180UH110XE60C 10150047EL16XC1S036-230B TXV 35,400 16 13 CX35-48C EL195UH090XE48C 10150048EL16XC1S036-230B TXV 35,600 16 13 CX35-48C EL195UH110XE60C 10150049EL16XC1S036-230B TXV 35,400 16 13 CX35-48C EL296UH090XE48C 10150050EL16XC1S036-230B TXV 35,400 16 13 CX35-48C EL296UH090XV36C 10150051EL16XC1S036-230B TXV 35,200 16 13 CX35-48C EL296UH090XV48C 10150052EL16XC1S036-230B TXV 35,600 16 13 CX35-48C EL296UH110XE60C 10150053EL16XC1S036-230B TXV 35,400 16 13 CX35-48C EL296UH110XV48C 10150054EL16XC1S036-230B TXV 35,800 16 13 CX35-48C EL296UH110XV60C 10150055EL16XC1S036-230B TXV 35,800 16 13 CX35-48C SL280UH090V60C 10150056EL16XC1S036-230B TXV 35,800 16 13 CX35-48C SL280UH090XV60C 10150057EL16XC1S036-230B TXV 35,600 16 13 CX35-48C SL280UH110V60C 10150058EL16XC1S036-230B TXV 35,600 16 13 CX35-48C SL280UH110XV60C 10150059EL16XC1S036-230B TXV 35,400 16 13 CX35-48C SLP98UH090XV36C 10150060EL16XC1S036-230B TXV 35,200 16 13 CX35-48C SLP98UH090XV48C 10150061EL16XC1S036-230B TXV 35,800 16 13 CX35-48C SLP98UH110XV60C 10150062EL16XC1S036-230B TXV 34,800 14.5 12.2 CX35-48C 10150044EL16XC1S036-230B TXV 36,000 16 13 CX35-49C EL180UH090E60C 10150064EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL180UH110E60C 10150065EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL180UH110XE60C 10150066EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL195UH090XE48C 10150067EL16XC1S036-230B TXV 36,000 16 13 CX35-49C EL195UH110XE60C 10150068EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL296UH090XE48C 10150069EL16XC1S036-230B TXV 35,800 16 13 CX35-49C EL296UH090XV36C 10150070EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL296UH090XV48C 10150071EL16XC1S036-230B TXV 36,000 16 13 CX35-49C EL296UH110XE60C 10150072EL16XC1S036-230B TXV 35,800 16 13 CX35-49C EL296UH110XV48C 10150073EL16XC1S036-230B TXV 36,000 16 13 CX35-49C EL296UH110XV60C 10150074EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SL280UH090V60C 10150075EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SL280UH090XV60C 10150076EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SL280UH110V60C 10150077EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SL280UH110XV60C 10150078EL16XC1S036-230B TXV 35,800 16 13 CX35-49C SLP98UH090XV36C 10150079EL16XC1S036-230B TXV 35,600 16 13 CX35-49C SLP98UH090XV48C 10150080EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SLP98UH110XV60C 10150081EL16XC1S036-230B TXV 35,200 14.5 12.2 CX35-49C 10150063EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C EL180UH090E60C 10150083EL16XC1S036-230B TXV 35,000 16 13 CX35-50/60C EL180UH110E60C 10150084EL16XC1S036-230B TXV 35,000 16 13 CX35-50/60C EL180UH110XE60C 10150085EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C EL195UH090XE48C 10150086EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C EL195UH110XE60C 10150087EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C EL296UH090XE48C 10150088EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C EL296UH090XV36C 10150089EL16XC1S036-230B TXV 35,000 16 13 CX35-50/60C EL296UH090XV48C 10150090EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C EL296UH110XE60C 10150091EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C EL296UH110XV48C 10150092NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 113: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 113

AHRI SYSTEM MATCHES - NORTH / SOUTH REGIONS - S036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,600 16 13 CX35-50/60C EL296UH110XV60C 10150093EL16XC1S036-230B TXV 35,600 16 13 CX35-50/60C SL280UH090V60C 10150094EL16XC1S036-230B TXV 35,600 16 13 CX35-50/60C SL280UH090XV60C 10150095EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C SL280UH110V60C 10150096EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C SL280UH110XV60C 10150097EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C SLP98UH090XV36C 10150098EL16XC1S036-230B TXV 35,000 16 13 CX35-50/60C SLP98UH090XV48C 10150099EL16XC1S036-230B TXV 35,600 16 13 CX35-50/60C SLP98UH110XV60C 10150100EL16XC1S036-230B TXV 34,600 14.5 12.2 CX35-50/60C 10150082NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device. AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 114: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B RFC 34,200 14.25 12.2 C33-38A 9125506EL16XC1S036-230B RFC 34,200 14.25 12.2 C33-38B 9125522EL16XC1S036-230B RFC 34,400 14.25 12.2 C33-43 9125552EL16XC1S036-230B RFC 34,800 14.5 12.2 C33-49 9125613EL16XC1S036-230B RFC 34,200 14.25 12.2 C33-50/60C 9125633EL16XC1S036-230B RFC 34,200 14.25 12.2 CH33-31B 9125853EL16XC1S036-230B RFC 35,000 14.5 12.2 CH33-43B 9125915EL16XC1S036-230B RFC 34,200 14.25 12.2 CH33-44/48B 9125949EL16XC1S036-230B RFC 34,400 14.25 12.2 CH33-48 9125969EL16XC1S036-230B RFC 34,800 14.5 12.2 CH33-49 9125989EL16XC1S036-230B RFC 34,600 14.5 12.2 CH33-50/60C 9126009EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-31A EL180UH045E36A 9125454EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-31A EL180UH045XE36A 9125455EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31A SL280UH070V36A 9125456EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31A SL280UH070XV36A 9125457EL16XC1S036-230B TXV 34,200 14.5 12 C33-31A 9126439EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31B EL180UH070E36B 9125458EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31B EL180UH070XE36B 9125459EL16XC1S036-230B TXV 34,400 15.5 12.5 C33-31B EL180UH090E48B 9125460EL16XC1S036-230B TXV 34,400 15.5 12.5 C33-31B EL180UH090XE48B 9125461EL16XC1S036-230B TXV 34,400 14.5 12.2 C33-31B EL195UH045XE36B 9125462EL16XC1S036-230B TXV 34,200 15.1 12.5 C33-31B EL195UH070XE36B 9125463EL16XC1S036-230B TXV 34,400 14.5 12.2 C33-31B EL296UH045XE36B 9125464EL16XC1S036-230B TXV 34,400 15.1 12.5 C33-31B EL296UH045XV36B 9125465EL16XC1S036-230B TXV 34,200 15.1 12.5 C33-31B EL296UH070XE36B 9125466EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31B EL296UH070XV36B 9125467EL16XC1S036-230B TXV 34,600 16 13 C33-31B SL280UH090V36B 9125468EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-31B SL280UH090V48B 9125469EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-31B SL280UH090XV48B 9125470EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-31B SLP98UH070XV36B 9125471EL16XC1S036-230B TXV 34,200 14.5 12 C33-31B 9126440EL16XC1S036-230B TXV 33,600 14.5 12.2 C33-36A EL180UH045E36A 9125472EL16XC1S036-230B TXV 33,600 14.5 12.2 C33-36A EL180UH045XE36A 9125473EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-36A SL280UH070V36A 9125474EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-36A SL280UH070XV36A 9125475EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36B EL180UH070E36B 9125476EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36B EL180UH070XE36B 9125477EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36B EL180UH090E48B 9125478EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36B EL180UH090XE48B 9125479EL16XC1S036-230B TXV 33,000 15.1 12.2 C33-36B EL195UH045XE36B 9125480EL16XC1S036-230B TXV 33,400 15.1 12.5 C33-36B EL195UH070XE36B 9125481EL16XC1S036-230B TXV 33,000 15.1 12.2 C33-36B EL296UH045XE36B 9125482EL16XC1S036-230B TXV 33,000 14.5 12.2 C33-36B EL296UH045XV36B 9125483EL16XC1S036-230B TXV 33,400 15.1 12.5 C33-36B EL296UH070XE36B 9125484EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-36B EL296UH070XV36B 9125485EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36B SL280UH090V36B 9125486EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36B SL280UH090V48B 9125487EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36B SL280UH090XV48B 9125488EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-36B SLP98UH070XV36B 9125489NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 115: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 115

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36C EL180UH090E60C 9125490EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36C EL180UH110E60C 9125491EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36C EL180UH110XE60C 9125492EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36C EL195UH090XE48C 9125493EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36C EL195UH110XE60C 9125494EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36C EL296UH090XE48C 9125495EL16XC1S036-230B TXV 33,600 15.1 12.5 C33-36C EL296UH090XV36C 9125496EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36C EL296UH090XV48C 9125497EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-36C EL296UH110XE60C 9125498EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-36C EL296UH110XV48C 9125499EL16XC1S036-230B TXV 33,600 15.1 12.5 C33-36C SLP98UH090XV36C 9125500EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-36C SLP98UH090XV48C 9125501EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38A EL180UH045E36A 9125502EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38A EL180UH045XE36A 9125503EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38A SL280UH070V36A 9125504EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38A SL280UH070XV36A 9125505EL16XC1S036-230B TXV 34,600 14.5 12.2 C33-38A 9125507EL16XC1S036-230B TXV 34,800 16 13 C33-38B EL180UH070E36B 9125508EL16XC1S036-230B TXV 34,800 16 13 C33-38B EL180UH070XE36B 9125509EL16XC1S036-230B TXV 35,200 16 13 C33-38B EL180UH090E48B 9125510EL16XC1S036-230B TXV 35,200 16 13 C33-38B EL180UH090XE48B 9125511EL16XC1S036-230B TXV 34,800 15.1 12.5 C33-38B EL195UH045XE36B 9125512EL16XC1S036-230B TXV 34,800 15.5 12.5 C33-38B EL195UH070XE36B 9125513EL16XC1S036-230B TXV 34,800 15.1 12.5 C33-38B EL296UH045XE36B 9125514EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38B EL296UH045XV36B 9125515EL16XC1S036-230B TXV 34,800 15.5 12.5 C33-38B EL296UH070XE36B 9125516EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38B EL296UH070XV36B 9125517EL16XC1S036-230B TXV 35,000 16 13 C33-38B SL280UH090V36B 9125518EL16XC1S036-230B TXV 35,200 16 13 C33-38B SL280UH090V48B 9125519EL16XC1S036-230B TXV 35,200 16 13 C33-38B SL280UH090XV48B 9125520EL16XC1S036-230B TXV 35,000 15.5 12.5 C33-38B SLP98UH070XV36B 9125521EL16XC1S036-230B TXV 34,600 14.5 12.2 C33-38B 9125523EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-42 EL180UH070E36B 9125524EL16XC1S036-230B TXV 33,400 15.5 12.5 C33-42 EL180UH070XE36B 9125525EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-42 EL180UH090E48B 9125526EL16XC1S036-230B TXV 33,800 15.5 12.5 C33-42 EL180UH090XE48B 9125527EL16XC1S036-230B TXV 33,000 15.1 12.2 C33-42 EL195UH045XE36B 9125528EL16XC1S036-230B TXV 33,400 15.1 12.5 C33-42 EL195UH070XE36B 9125529EL16XC1S036-230B TXV 33,000 15.1 12.2 C33-42 EL296UH045XE36B 9125530EL16XC1S036-230B TXV 33,000 14.5 12.2 C33-42 EL296UH045XV36B 9125531EL16XC1S036-230B TXV 33,400 15.1 12.5 C33-42 EL296UH070XE36B 9125532EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-42 EL296UH070XV36B 9125533EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-42 SL280UH090V36B 9125534EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-42 SL280UH090V48B 9125535EL16XC1S036-230B TXV 33,600 15.5 12.5 C33-42 SL280UH090XV48B 9125536EL16XC1S036-230B TXV 33,200 15.1 12.5 C33-42 SLP98UH070XV36B 9125537EL16XC1S036-230B TXV 35,200 16 13 C33-43B EL180UH070E36B 9125538EL16XC1S036-230B TXV 35,200 16 13 C33-43B EL180UH070XE36B 9125539EL16XC1S036-230B TXV 35,600 16 13 C33-43B EL180UH090E48B 9125540NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 116: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 116

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,600 16 13 C33-43B EL180UH090XE48B 9125541EL16XC1S036-230B TXV 35,000 15.1 12.5 C33-43B EL195UH045XE36B 9125542EL16XC1S036-230B TXV 35,000 16 13 C33-43B EL195UH070XE36B 9125543EL16XC1S036-230B TXV 35,000 15.1 12.5 C33-43B EL296UH045XE36B 9125544EL16XC1S036-230B TXV 35,200 15.5 12.5 C33-43B EL296UH045XV36B 9125545EL16XC1S036-230B TXV 35,000 16 13 C33-43B EL296UH070XE36B 9125546EL16XC1S036-230B TXV 35,200 15.5 12.5 C33-43B EL296UH070XV36B 9125547EL16XC1S036-230B TXV 35,200 16 13 C33-43B SL280UH090V36B 9125548EL16XC1S036-230B TXV 35,400 16 13 C33-43B SL280UH090V48B 9125549EL16XC1S036-230B TXV 35,400 16 13 C33-43B SL280UH090XV48B 9125550EL16XC1S036-230B TXV 35,200 15.5 12.5 C33-43B SLP98UH070XV36B 9125551EL16XC1S036-230B TXV 34,800 14.5 12.2 C33-43B 9125553EL16XC1S036-230B TXV 35,600 16 13 C33-43C EL180UH090E60C 9125554EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL180UH110E60C 9125555EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL180UH110XE60C 9125556EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL195UH090XE48C 9125557EL16XC1S036-230B TXV 35,600 16 13 C33-43C EL195UH110XE60C 9125558EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL296UH090XE48C 9125559EL16XC1S036-230B TXV 35,400 16 13 C33-43C EL296UH090XV36C 9125560EL16XC1S036-230B TXV 35,200 16 13 C33-43C EL296UH090XV48C 9125561EL16XC1S036-230B TXV 35,600 16 13 C33-43C EL296UH110XE60C 9125562EL16XC1S036-230B TXV 35,400 16 13 C33-43C EL296UH110XV48C 9125563EL16XC1S036-230B TXV 35,600 16 13 C33-43C EL296UH110XV60C 9125564EL16XC1S036-230B TXV 35,800 16 13 C33-43C SL280UH090V60C 9125565EL16XC1S036-230B TXV 35,800 16 13 C33-43C SL280UH090XV60C 9125566EL16XC1S036-230B TXV 35,600 16 13 C33-43C SL280UH110V60C 9125567EL16XC1S036-230B TXV 35,600 16 13 C33-43C SL280UH110XV60C 9125568EL16XC1S036-230B TXV 35,400 16 13 C33-43C SLP98UH090XV36C 9125569EL16XC1S036-230B TXV 35,200 16 13 C33-43C SLP98UH090XV48C 9125570EL16XC1S036-230B TXV 35,600 16 13 C33-43C SLP98UH110XV60C 9125571EL16XC1S036-230B TXV 34,400 14.25 12.2 C33-43C 9126453EL16XC1S036-230B TXV 34,800 14.5 12.2 C33-43C 9125572EL16XC1S036-230B TXV 34,200 14.5 12 C33-44C 9126441EL16XC1S036-230B TXV 34,600 16 13 C33-48B EL180UH070E36B 9125573EL16XC1S036-230B TXV 34,600 16 13 C33-48B EL180UH070XE36B 9125574EL16XC1S036-230B TXV 35,000 16 13 C33-48B EL180UH090E48B 9125575EL16XC1S036-230B TXV 35,000 16 13 C33-48B EL180UH090XE48B 9125576EL16XC1S036-230B TXV 34,200 15.5 12.5 C33-48B EL195UH045XE36B 9125577EL16XC1S036-230B TXV 34,400 15.5 12.5 C33-48B EL195UH070XE36B 9125578EL16XC1S036-230B TXV 34,200 15.5 12.5 C33-48B EL296UH045XE36B 9125579EL16XC1S036-230B TXV 34,600 15.1 12.5 C33-48B EL296UH045XV36B 9125580EL16XC1S036-230B TXV 34,400 15.5 12.5 C33-48B EL296UH070XE36B 9125581EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-48B EL296UH070XV36B 9125582EL16XC1S036-230B TXV 34,800 16 13 C33-48B SL280UH090V36B 9125583EL16XC1S036-230B TXV 34,800 16 13 C33-48B SL280UH090V48B 9125584EL16XC1S036-230B TXV 34,800 16 13 C33-48B SL280UH090XV48B 9125585EL16XC1S036-230B TXV 34,600 15.5 12.5 C33-48B SLP98UH070XV36B 9125586EL16XC1S036-230B TXV 34,200 14.5 12 C33-48B 9126442EL16XC1S036-230B TXV 34,600 16 13 C33-48C EL195UH090XE48C 9125587NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 117: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 117

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,000 16 13 C33-48C EL195UH110XE60C 9125588EL16XC1S036-230B TXV 34,600 16 13 C33-48C EL296UH090XE48C 9125589EL16XC1S036-230B TXV 34,800 16 13 C33-48C EL296UH090XV36C 9125590EL16XC1S036-230B TXV 34,600 16 13 C33-48C EL296UH090XV48C 9125591EL16XC1S036-230B TXV 35,000 16 13 C33-48C EL296UH110XE60C 9125592EL16XC1S036-230B TXV 34,800 16 13 C33-48C SLP98UH090XV36C 9125593EL16XC1S036-230B TXV 34,600 16 13 C33-48C SLP98UH090XV48C 9125594EL16XC1S036-230B TXV 34,200 14.5 12 C33-48C 9126443EL16XC1S036-230B TXV 35,800 16 13 C33-49 EL180UH090E60C 9125595EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL180UH110E60C 9125596EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL180UH110XE60C 9125597EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL195UH090XE48C 9125598EL16XC1S036-230B TXV 36,000 16 13 C33-49 EL195UH110XE60C 9125599EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL296UH090XE48C 9125600EL16XC1S036-230B TXV 35,800 16 13 C33-49 EL296UH090XV36C 9125601EL16XC1S036-230B TXV 35,600 16 13 C33-49 EL296UH090XV48C 9125602EL16XC1S036-230B TXV 36,000 16 13 C33-49 EL296UH110XE60C 9125603EL16XC1S036-230B TXV 35,800 16 13 C33-49 EL296UH110XV48C 9125604EL16XC1S036-230B TXV 36,000 16 13 C33-49 EL296UH110XV60C 9125605EL16XC1S036-230B TXV 36,000 16 13 C33-49 SL280UH090V60C 9125606EL16XC1S036-230B TXV 36,000 16 13 C33-49 SL280UH090XV60C 9125607EL16XC1S036-230B TXV 36,000 16 13 C33-49 SL280UH110V60C 9125608EL16XC1S036-230B TXV 36,000 16 13 C33-49 SL280UH110XV60C 9125609EL16XC1S036-230B TXV 35,800 16 13 C33-49 SLP98UH090XV36C 9125610EL16XC1S036-230B TXV 35,600 16 13 C33-49 SLP98UH090XV48C 9125611EL16XC1S036-230B TXV 36,000 16 13 C33-49 SLP98UH110XV60C 9125612EL16XC1S036-230B TXV 35,200 14.5 12.2 C33-49 9125614EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C EL180UH090E60C 9125615EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL180UH110E60C 9125616EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL180UH110XE60C 9125617EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL195UH090XE48C 9125618EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C EL195UH110XE60C 9125619EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL296UH090XE48C 9125620EL16XC1S036-230B TXV 35,200 16 13 C33-50/60C EL296UH090XV36C 9125621EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C EL296UH090XV48C 9125622EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C EL296UH110XE60C 9125623EL16XC1S036-230B TXV 35,200 16 13 C33-50/60C EL296UH110XV48C 9125624EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C EL296UH110XV60C 9125625EL16XC1S036-230B TXV 35,600 16 13 C33-50/60C SL280UH090V60C 9125626EL16XC1S036-230B TXV 35,600 16 13 C33-50/60C SL280UH090XV60C 9125627EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C SL280UH110V60C 9125628EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C SL280UH110XV60C 9125629EL16XC1S036-230B TXV 35,200 16 13 C33-50/60C SLP98UH090XV36C 9125630EL16XC1S036-230B TXV 35,000 16 13 C33-50/60C SLP98UH090XV48C 9125631EL16XC1S036-230B TXV 35,400 16 13 C33-50/60C SLP98UH110XV60C 9125632EL16XC1S036-230B TXV 34,600 14.5 12.2 C33-50/60C 9125634EL16XC1S036-230B TXV 33,600 15.1 12.2 C35-30/36A EL180UH045E36A 9125635EL16XC1S036-230B TXV 33,600 15.1 12.2 C35-30/36A EL180UH045XE36A 9125636EL16XC1S036-230B TXV 33,400 15.1 12.5 C35-30/36A SL280UH070V36A 9125637NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 118: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 118

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,400 15.1 12.5 C35-30/36A SL280UH070XV36A 9125638EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36B EL180UH070E36B 9125639EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36B EL180UH070XE36B 9125640EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36B EL180UH090E48B 9125641EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36B EL180UH090XE48B 9125642EL16XC1S036-230B TXV 33,200 15.1 12.5 C35-30/36B EL195UH045XE36B 9125643EL16XC1S036-230B TXV 33,200 15.1 12.5 C35-30/36B EL296UH045XE36B 9125644EL16XC1S036-230B TXV 33,200 15.1 12.2 C35-30/36B EL296UH045XV36B 9125645EL16XC1S036-230B TXV 33,400 15.1 12.5 C35-30/36B EL296UH070XV36B 9125646EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36B SL280UH090V36B 9125647EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36B SL280UH090V48B 9125648EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36B SL280UH090XV48B 9125649EL16XC1S036-230B TXV 33,400 15.1 12.5 C35-30/36B SLP98UH070XV36B 9125650EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36C EL180UH090E60C 9125651EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL180UH110E60C 9125652EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL180UH110XE60C 9125653EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL195UH090XE48C 9125654EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36C EL195UH110XE60C 9125655EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL296UH090XE48C 9125656EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36C EL296UH090XV36C 9125657EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C EL296UH090XV48C 9125658EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36C EL296UH110XE60C 9125659EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36C EL296UH110XV48C 9125660EL16XC1S036-230B TXV 33,800 15.5 12.5 C35-30/36C SLP98UH090XV36C 9125661EL16XC1S036-230B TXV 33,600 15.5 12.5 C35-30/36C SLP98UH090XV48C 9125662EL16XC1S036-230B TXV 34,000 15.5 12.5 C35-30/36C SLP98UH110XV60C 9125663EL16XC1S036-230B TXV 34,800 15.5 12.5 C35-30A EL180UH045E36A 9125664EL16XC1S036-230B TXV 34,800 15.5 12.5 C35-30A EL180UH045XE36A 9125665EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30A SL280UH070V36A 9125666EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30A SL280UH070XV36A 9125667EL16XC1S036-230B TXV 34,400 16 13 C35-30B EL180UH070E36B 9125668EL16XC1S036-230B TXV 34,400 16 13 C35-30B EL180UH070XE36B 9125669EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30B EL180UH090E48B 9125670EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30B EL180UH090XE48B 9125671EL16XC1S036-230B TXV 34,400 14.5 12.2 C35-30B EL195UH045XE36B 9125672EL16XC1S036-230B TXV 34,400 15.5 12.5 C35-30B EL195UH070XE36B 9125673EL16XC1S036-230B TXV 34,400 14.5 12.2 C35-30B EL296UH045XE36B 9125674EL16XC1S036-230B TXV 34,600 15.1 12.5 C35-30B EL296UH045XV36B 9125675EL16XC1S036-230B TXV 34,400 15.5 12.5 C35-30B EL296UH070XE36B 9125676EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30B EL296UH070XV36B 9125677EL16XC1S036-230B TXV 34,800 16 13 C35-30B SL280UH090V36B 9125678EL16XC1S036-230B TXV 34,800 16 13 C35-30B SL280UH090V48B 9125679EL16XC1S036-230B TXV 34,800 16 13 C35-30B SL280UH090XV48B 9125680EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-30B SLP98UH070XV36B 9125681EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-36A EL180UH045E36A 9125682EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-36A EL180UH045XE36A 9125683EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36A SL280UH070V36A 9125684EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36A SL280UH070XV36A 9125685EL16XC1S036-230B TXV 34,600 14.5 12.2 C35-36A 9125686NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 119: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 119

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,000 16 13 C35-36B EL180UH070E36B 9125687EL16XC1S036-230B TXV 35,000 16 13 C35-36B EL180UH070XE36B 9125688EL16XC1S036-230B TXV 35,400 16 13 C35-36B EL180UH090E48B 9125689EL16XC1S036-230B TXV 35,400 16 13 C35-36B EL180UH090XE48B 9125690EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-36B EL195UH045XE36B 9125691EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B EL195UH070XE36B 9125692EL16XC1S036-230B TXV 34,600 15.5 12.5 C35-36B EL296UH045XE36B 9125693EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B EL296UH045XV36B 9125694EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B EL296UH070XE36B 9125695EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B EL296UH070XV36B 9125696EL16XC1S036-230B TXV 35,200 16 13 C35-36B SL280UH090V36B 9125697EL16XC1S036-230B TXV 35,200 16 13 C35-36B SL280UH090V48B 9125698EL16XC1S036-230B TXV 35,200 16 13 C35-36B SL280UH090XV48B 9125699EL16XC1S036-230B TXV 35,000 15.5 12.5 C35-36B SLP98UH070XV36B 9125700EL16XC1S036-230B TXV 34,600 14.5 12.2 C35-36B 9125701EL16XC1S036-230B TXV 35,200 16 13 C35-48B EL180UH070E36B 9125702EL16XC1S036-230B TXV 35,200 16 13 C35-48B EL180UH070XE36B 9125703EL16XC1S036-230B TXV 35,600 16 13 C35-48B EL180UH090E48B 9125704EL16XC1S036-230B TXV 35,600 16 13 C35-48B EL180UH090XE48B 9125705EL16XC1S036-230B TXV 34,800 15.5 12.5 C35-48B EL195UH045XE36B 9125706EL16XC1S036-230B TXV 35,200 16 13 C35-48B EL195UH070XE36B 9125707EL16XC1S036-230B TXV 34,800 15.5 12.5 C35-48B EL296UH045XE36B 9125708EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-48B EL296UH045XV36B 9125709EL16XC1S036-230B TXV 35,200 16 13 C35-48B EL296UH070XE36B 9125710EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-48B EL296UH070XV36B 9125711EL16XC1S036-230B TXV 35,400 16 13 C35-48B SL280UH090V36B 9125712EL16XC1S036-230B TXV 35,400 16 13 C35-48B SL280UH090V48B 9125713EL16XC1S036-230B TXV 35,400 16 13 C35-48B SL280UH090XV48B 9125714EL16XC1S036-230B TXV 35,200 15.5 12.5 C35-48B SLP98UH070XV36B 9125715EL16XC1S036-230B TXV 34,800 14.5 12.2 C35-48B 9125716EL16XC1S036-230B TXV 35,600 16 13 C35-48C EL180UH090E60C 9125717EL16XC1S036-230B TXV 35,200 16 13 C35-48C EL180UH110E60C 9125718EL16XC1S036-230B TXV 35,200 16 13 C35-48C EL180UH110XE60C 9125719EL16XC1S036-230B TXV 35,400 16 13 C35-48C EL195UH090XE48C 9125720EL16XC1S036-230B TXV 35,600 16 13 C35-48C EL195UH110XE60C 9125721EL16XC1S036-230B TXV 35,400 16 13 C35-48C EL296UH090XE48C 9125722EL16XC1S036-230B TXV 35,400 16 13 C35-48C EL296UH090XV36C 9125723EL16XC1S036-230B TXV 35,200 16 13 C35-48C EL296UH090XV48C 9125724EL16XC1S036-230B TXV 35,600 16 13 C35-48C EL296UH110XE60C 9125725EL16XC1S036-230B TXV 35,400 16 13 C35-48C EL296UH110XV48C 9125726EL16XC1S036-230B TXV 35,800 16 13 C35-48C EL296UH110XV60C 9125727EL16XC1S036-230B TXV 35,800 16 13 C35-48C SL280UH090V60C 9125728EL16XC1S036-230B TXV 35,800 16 13 C35-48C SL280UH090XV60C 9125729EL16XC1S036-230B TXV 35,800 16 13 C35-48C SL280UH110V60C 9125730EL16XC1S036-230B TXV 35,800 16 13 C35-48C SL280UH110XV60C 9125731EL16XC1S036-230B TXV 35,400 16 13 C35-48C SLP98UH090XV36C 9125732EL16XC1S036-230B TXV 35,200 16 13 C35-48C SLP98UH090XV48C 9125733EL16XC1S036-230B TXV 35,800 16 13 C35-48C SLP98UH110XV60C 9125734EL16XC1S036-230B TXV 34,800 14.5 12.2 C35-48C 9125735NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 120: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 120

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 36,000 16 13 C35-49C EL180UH090E60C 9125736EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL180UH110E60C 9125737EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL180UH110XE60C 9125738EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL195UH090XE48C 9125739EL16XC1S036-230B TXV 36,000 16 13 C35-49C EL195UH110XE60C 9125740EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL296UH090XE48C 9125741EL16XC1S036-230B TXV 35,800 16 13 C35-49C EL296UH090XV36C 9125742EL16XC1S036-230B TXV 35,600 16 13 C35-49C EL296UH090XV48C 9125743EL16XC1S036-230B TXV 36,000 16 13 C35-49C EL296UH110XE60C 9125744EL16XC1S036-230B TXV 35,800 16 13 C35-49C EL296UH110XV48C 9125745EL16XC1S036-230B TXV 36,000 16 13 C35-49C EL296UH110XV60C 9125746EL16XC1S036-230B TXV 36,000 16 13 C35-49C SL280UH090V60C 9125747EL16XC1S036-230B TXV 36,000 16 13 C35-49C SL280UH090XV60C 9125748EL16XC1S036-230B TXV 36,000 16 13 C35-49C SL280UH110V60C 9125749EL16XC1S036-230B TXV 36,000 16 13 C35-49C SL280UH110XV60C 9125750EL16XC1S036-230B TXV 35,800 16 13 C35-49C SLP98UH090XV36C 9125751EL16XC1S036-230B TXV 35,600 16 13 C35-49C SLP98UH090XV48C 9125752EL16XC1S036-230B TXV 36,000 16 13 C35-49C SLP98UH110XV60C 9125753EL16XC1S036-230B TXV 35,200 14.5 12.2 C35-49C 9125754EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C EL180UH090E60C 9125755EL16XC1S036-230B TXV 35,000 16 13 C35-50/60C EL180UH110E60C 9125756EL16XC1S036-230B TXV 35,000 16 13 C35-50/60C EL180UH110XE60C 9125757EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C EL195UH090XE48C 9125758EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C EL195UH110XE60C 9125759EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C EL296UH090XE48C 9125760EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C EL296UH090XV36C 9125761EL16XC1S036-230B TXV 35,000 16 13 C35-50/60C EL296UH090XV48C 9125762EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C EL296UH110XE60C 9125763EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C EL296UH110XV48C 9125764EL16XC1S036-230B TXV 35,600 16 13 C35-50/60C EL296UH110XV60C 9125765EL16XC1S036-230B TXV 35,600 16 13 C35-50/60C SL280UH090V60C 9125766EL16XC1S036-230B TXV 35,600 16 13 C35-50/60C SL280UH090XV60C 9125767EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C SL280UH110V60C 9125768EL16XC1S036-230B TXV 35,400 16 13 C35-50/60C SL280UH110XV60C 9125769EL16XC1S036-230B TXV 35,200 16 13 C35-50/60C SLP98UH090XV36C 9125770EL16XC1S036-230B TXV 35,000 16 13 C35-50/60C SLP98UH090XV48C 9125771EL16XC1S036-230B TXV 35,600 16 13 C35-50/60C SLP98UH110XV60C 9125772EL16XC1S036-230B TXV 34,600 14.5 12.2 C35-50/60C 9125773EL16XC1S036-230B TXV 34,600 16 13 CBA27UHE-036 10259409EL16XC1S036-230B TXV 35,400 16 13 CBA27UHE-042 10259410EL16XC1S036-230B TXV 33,800 14.5 12 CBX25UH-036 9126444EL16XC1S036-230B TXV 34,600 15.1 12.5 CBX25UH-042 9125774EL16XC1S036-230B TXV 33,800 15.1 12.5 CBX25UHV-036 9125775EL16XC1S036-230B TXV 35,000 16 13 CBX25UHV-042 9125776EL16XC1S036-230B TXV 34,400 16 13 CBX27UH-036 9125777EL16XC1S036-230B TXV 35,200 16 13 CBX27UH-042 9125778EL16XC1S036-230B TXV 33,800 15.1 12.5 CBX32M-030 9125779EL16XC1S036-230B TXV 34,000 14.5 12.2 CBX32M-036 9125780EL16XC1S036-230B TXV 34,000 14.5 12.2 CBX32M-042 9125781NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 121: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 121

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,600 15 12.5 CBX32M-048 9125782EL16XC1S036-230B TXV 34,200 15.1 12.5 CBX32MV-036 9125783EL16XC1S036-230B TXV 35,200 16 13 CBX32MV-048 9125784EL16XC1S036-230B TXV 34,400 15.5 12.5 CBX40UHV-036 9125785EL16XC1S036-230B TXV 35,000 16 13 CBX40UHV-042 9125786EL16XC1S036-230B TXV 35,200 16 13 CBX40UHV-048 9125787EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL180UH045E36A 9125788EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL180UH045XE36A 9125789EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 EL180UH070E36B 9125790EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 EL180UH070XE36B 9125791EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 EL180UH090E48B 9125792EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 EL180UH090XE48B 9125793EL16XC1S036-230B TXV 33,400 15.1 12.5 CH23-41 EL195UH045XE36B 9125794EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL195UH070XE36B 9125795EL16XC1S036-230B TXV 33,400 15.1 12.5 CH23-41 EL296UH045XE36B 9125796EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL296UH045XV36B 9125797EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL296UH070XE36B 9125798EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 EL296UH070XV36B 9125799EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 SL280UH090V48B 9125800EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-41 SL280UH090XV48B 9125801EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-41 SLP98UH070XV36B 9125802EL16XC1S036-230B TXV 33,600 15.1 12.2 CH23-51 EL180UH045E36A 9125803EL16XC1S036-230B TXV 33,600 15.1 12.2 CH23-51 EL180UH045XE36A 9125804EL16XC1S036-230B TXV 33,800 16 13 CH23-51 EL180UH070E36B 9125805EL16XC1S036-230B TXV 33,800 16 13 CH23-51 EL180UH070XE36B 9125806EL16XC1S036-230B TXV 34,200 15.5 12.5 CH23-51 EL180UH090E48B 9125807EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL180UH090E60C 9125808EL16XC1S036-230B TXV 34,200 15.5 12.5 CH23-51 EL180UH090XE48B 9125809EL16XC1S036-230B TXV 34,000 16 13 CH23-51 EL180UH110E60C 9125810EL16XC1S036-230B TXV 34,000 16 13 CH23-51 EL180UH110XE60C 9125811EL16XC1S036-230B TXV 33,400 15.1 12.5 CH23-51 EL195UH045XE36B 9125812EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 EL195UH070XE36B 9125813EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL195UH090XE48C 9125814EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL195UH110XE60C 9125815EL16XC1S036-230B TXV 33,400 15.1 12.5 CH23-51 EL296UH045XE36B 9125816EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 EL296UH045XV36B 9125817EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 EL296UH070XE36B 9125818EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 EL296UH070XV36B 9125819EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL296UH090XE48C 9125820EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 EL296UH090XV36C 9125821EL16XC1S036-230B TXV 33,600 15.5 12.5 CH23-51 EL296UH090XV48C 9125822EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 EL296UH110XE60C 9125823EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 EL296UH110XV48C 9125824EL16XC1S036-230B TXV 34,200 15.5 12.5 CH23-51 EL296UH110XV60C 9125825EL16XC1S036-230B TXV 33,800 16 13 CH23-51 SL280UH090V36B 9125826EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 SL280UH090V48B 9125827EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 SL280UH090XV48B 9125828EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 SL280UH110V60C 9125829EL16XC1S036-230B TXV 34,000 15.5 12.5 CH23-51 SL280UH110XV60C 9125830NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 122: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 122

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,600 15.1 12.5 CH23-51 SLP98UH070XV36B 9125831EL16XC1S036-230B TXV 33,800 15.5 12.5 CH23-51 SLP98UH090XV36C 9125832EL16XC1S036-230B TXV 33,600 15.5 12.5 CH23-51 SLP98UH090XV48C 9125833EL16XC1S036-230B TXV 34,200 15.5 12.5 CH23-51 SLP98UH110XV60C 9125834EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-31A EL180UH045E36A 9125835EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-31A EL180UH045XE36A 9125836EL16XC1S036-230B TXV 34,600 15.1 12.5 CH33-31A SL280UH070V36A 9125837EL16XC1S036-230B TXV 34,600 15.1 12.5 CH33-31A SL280UH070XV36A 9125838EL16XC1S036-230B TXV 34,600 16 13 CH33-31B EL180UH070E36B 9125839EL16XC1S036-230B TXV 34,600 16 13 CH33-31B EL180UH070XE36B 9125840EL16XC1S036-230B TXV 34,800 16 13 CH33-31B EL180UH090E48B 9125841EL16XC1S036-230B TXV 34,800 16 13 CH33-31B EL180UH090XE48B 9125842EL16XC1S036-230B TXV 34,600 15.1 12.2 CH33-31B EL195UH045XE36B 9125843EL16XC1S036-230B TXV 34,600 15.5 12.5 CH33-31B EL195UH070XE36B 9125844EL16XC1S036-230B TXV 34,600 15.1 12.2 CH33-31B EL296UH045XE36B 9125845EL16XC1S036-230B TXV 34,800 15.5 12.5 CH33-31B EL296UH045XV36B 9125846EL16XC1S036-230B TXV 34,600 15.5 12.5 CH33-31B EL296UH070XE36B 9125847EL16XC1S036-230B TXV 34,800 15.5 12.5 CH33-31B EL296UH070XV36B 9125848EL16XC1S036-230B TXV 35,000 16 13 CH33-31B SL280UH090V36B 9125849EL16XC1S036-230B TXV 35,000 16 13 CH33-31B SL280UH090V48B 9125850EL16XC1S036-230B TXV 35,000 16 13 CH33-31B SL280UH090XV48B 9125851EL16XC1S036-230B TXV 34,800 15.5 12.5 CH33-31B SLP98UH070XV36B 9125852EL16XC1S036-230B TXV 34,400 14.5 12.2 CH33-31B 9125854EL16XC1S036-230B TXV 33,400 14.5 12.2 CH33-36A EL180UH045E36A 9125855EL16XC1S036-230B TXV 33,400 14.5 12.2 CH33-36A EL180UH045XE36A 9125856EL16XC1S036-230B TXV 33,200 14.5 12 CH33-36A SL280UH070V36A 9126445EL16XC1S036-230B TXV 33,200 14.5 12 CH33-36A SL280UH070XV36A 9126446EL16XC1S036-230B TXV 33,400 15.5 12.5 CH33-36B EL180UH070E36B 9125857EL16XC1S036-230B TXV 33,400 15.5 12.5 CH33-36B EL180UH070XE36B 9125858EL16XC1S036-230B TXV 33,600 15.5 12.5 CH33-36B EL180UH090E48B 9125859EL16XC1S036-230B TXV 33,600 15.5 12.5 CH33-36B EL180UH090XE48B 9125860EL16XC1S036-230B TXV 33,000 14.5 12.2 CH33-36B EL195UH045XE36B 9125861EL16XC1S036-230B TXV 33,200 15.1 12.5 CH33-36B EL195UH070XE36B 9125862EL16XC1S036-230B TXV 33,000 14.5 12.2 CH33-36B EL296UH045XE36B 9125863EL16XC1S036-230B TXV 33,400 14.5 12.2 CH33-36B EL296UH045XV36B 9125864EL16XC1S036-230B TXV 33,200 15.1 12.5 CH33-36B EL296UH070XE36B 9125865EL16XC1S036-230B TXV 33,200 15.1 12.5 CH33-36B EL296UH070XV36B 9125866EL16XC1S036-230B TXV 33,400 15.5 12.5 CH33-36B SL280UH090V36B 9125867EL16XC1S036-230B TXV 33,600 15.5 12.5 CH33-36B SL280UH090V48B 9125868EL16XC1S036-230B TXV 33,600 15.5 12.5 CH33-36B SL280UH090XV48B 9125869EL16XC1S036-230B TXV 33,200 15.1 12.5 CH33-36B SLP98UH070XV36B 9125870EL16XC1S036-230B TXV 34,200 16 13 CH33-36C EL180UH090E60C 9125871EL16XC1S036-230B TXV 34,000 16 13 CH33-36C EL180UH110E60C 9125872EL16XC1S036-230B TXV 34,000 16 13 CH33-36C EL180UH110XE60C 9125873EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL195UH090XE48C 9125874EL16XC1S036-230B TXV 34,200 15.5 12.5 CH33-36C EL195UH110XE60C 9125875EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL296UH090XE48C 9125876EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL296UH090XV36C 9125877EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL296UH090XV48C 9125878NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 123: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 123

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,200 15.5 12.5 CH33-36C EL296UH110XE60C 9125879EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C EL296UH110XV48C 9125880EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-36C EL296UH110XV60C 9125881EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-36C SL280UH110V60C 9125882EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-36C SL280UH110XV60C 9125883EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C SLP98UH090XV36C 9125884EL16XC1S036-230B TXV 34,000 15.5 12.5 CH33-36C SLP98UH090XV48C 9125885EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-36C SLP98UH110XV60C 9125886EL16XC1S036-230B TXV 34,200 16 13 CH33-42B EL180UH070E36B 9125887EL16XC1S036-230B TXV 34,200 16 13 CH33-42B EL180UH070XE36B 9125888EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-42B EL180UH090E48B 9125889EL16XC1S036-230B TXV 34,400 15.5 12.5 CH33-42B EL180UH090XE48B 9125890EL16XC1S036-230B TXV 34,200 14.5 12.2 CH33-42B EL195UH045XE36B 9125891EL16XC1S036-230B TXV 34,000 15.1 12.5 CH33-42B EL195UH070XE36B 9125892EL16XC1S036-230B TXV 34,200 14.5 12.2 CH33-42B EL296UH045XE36B 9125893EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-42B EL296UH045XV36B 9125894EL16XC1S036-230B TXV 34,000 15.1 12.5 CH33-42B EL296UH070XE36B 9125895EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-42B EL296UH070XV36B 9125896EL16XC1S036-230B TXV 34,600 16 13 CH33-42B SL280UH090V36B 9125897EL16XC1S036-230B TXV 34,600 15.5 12.5 CH33-42B SL280UH090V48B 9125898EL16XC1S036-230B TXV 34,600 15.5 12.5 CH33-42B SL280UH090XV48B 9125899EL16XC1S036-230B TXV 34,400 15.1 12.5 CH33-42B SLP98UH070XV36B 9125900EL16XC1S036-230B TXV 35,600 16 13 CH33-43B EL180UH070E36B 9125901EL16XC1S036-230B TXV 35,600 16 13 CH33-43B EL180UH070XE36B 9125902EL16XC1S036-230B TXV 35,800 16 13 CH33-43B EL180UH090E48B 9125903EL16XC1S036-230B TXV 35,800 16 13 CH33-43B EL180UH090XE48B 9125904EL16XC1S036-230B TXV 35,600 15.5 12.5 CH33-43B EL195UH045XE36B 9125905EL16XC1S036-230B TXV 35,400 16 13 CH33-43B EL195UH070XE36B 9125906EL16XC1S036-230B TXV 35,600 15.5 12.5 CH33-43B EL296UH045XE36B 9125907EL16XC1S036-230B TXV 35,800 16 13 CH33-43B EL296UH045XV36B 9125908EL16XC1S036-230B TXV 35,400 16 13 CH33-43B EL296UH070XE36B 9125909EL16XC1S036-230B TXV 35,800 16 13 CH33-43B EL296UH070XV36B 9125910EL16XC1S036-230B TXV 36,000 16 13 CH33-43B SL280UH090V36B 9125911EL16XC1S036-230B TXV 36,000 16 13 CH33-43B SL280UH090V48B 9125912EL16XC1S036-230B TXV 36,000 16 13 CH33-43B SL280UH090XV48B 9125913EL16XC1S036-230B TXV 35,800 16 13 CH33-43B SLP98UH070XV36B 9125914EL16XC1S036-230B TXV 35,400 15.1 12.5 CH33-43B 9125916EL16XC1S036-230B TXV 35,600 16 13 CH33-43C EL180UH090E60C 9125917EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL180UH110E60C 9125918EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL180UH110XE60C 9125919EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL195UH090XE48C 9125920EL16XC1S036-230B TXV 35,600 16 13 CH33-43C EL195UH110XE60C 9125921EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL296UH090XE48C 9125922EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL296UH090XV36C 9125923EL16XC1S036-230B TXV 35,200 16 13 CH33-43C EL296UH090XV48C 9125924EL16XC1S036-230B TXV 35,600 16 13 CH33-43C EL296UH110XE60C 9125925EL16XC1S036-230B TXV 35,400 16 13 CH33-43C EL296UH110XV48C 9125926EL16XC1S036-230B TXV 35,800 16 13 CH33-43C EL296UH110XV60C 9125927EL16XC1S036-230B TXV 35,800 16 13 CH33-43C SL280UH090V60C 9125928NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 124: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 124

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,800 16 13 CH33-43C SL280UH090XV60C 9125929EL16XC1S036-230B TXV 35,600 16 13 CH33-43C SL280UH110V60C 9125930EL16XC1S036-230B TXV 35,600 16 13 CH33-43C SL280UH110XV60C 9125931EL16XC1S036-230B TXV 35,400 16 13 CH33-43C SLP98UH090XV36C 9125932EL16XC1S036-230B TXV 35,200 16 13 CH33-43C SLP98UH090XV48C 9125933EL16XC1S036-230B TXV 35,800 16 13 CH33-43C SLP98UH110XV60C 9125934EL16XC1S036-230B TXV 34,600 16 13 CH33-44/48B EL180UH070E36B 9125935EL16XC1S036-230B TXV 34,600 16 13 CH33-44/48B EL180UH070XE36B 9125936EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B EL180UH090E48B 9125937EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B EL180UH090XE48B 9125938EL16XC1S036-230B TXV 34,800 15.1 12.5 CH33-44/48B EL195UH045XE36B 9125939EL16XC1S036-230B TXV 34,800 15.1 12.5 CH33-44/48B EL195UH070XE36B 9125940EL16XC1S036-230B TXV 34,800 15.1 12.5 CH33-44/48B EL296UH045XE36B 9125941EL16XC1S036-230B TXV 34,800 15.5 12.5 CH33-44/48B EL296UH045XV36B 9125942EL16XC1S036-230B TXV 34,800 15.1 12.5 CH33-44/48B EL296UH070XE36B 9125943EL16XC1S036-230B TXV 35,000 15.5 12.5 CH33-44/48B EL296UH070XV36B 9125944EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B SL280UH090V36B 9125945EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B SL280UH090V48B 9125946EL16XC1S036-230B TXV 35,000 16 13 CH33-44/48B SL280UH090XV48B 9125947EL16XC1S036-230B TXV 35,000 15.5 12.5 CH33-44/48B SLP98UH070XV36B 9125948EL16XC1S036-230B TXV 34,600 14.5 12.2 CH33-44/48B 9125950EL16XC1S036-230B TXV 35,400 16 13 CH33-48C EL180UH090E60C 9125951EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL180UH110E60C 9125952EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL180UH110XE60C 9125953EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL195UH090XE48C 9125954EL16XC1S036-230B TXV 35,400 16 13 CH33-48C EL195UH110XE60C 9125955EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL296UH090XE48C 9125956EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL296UH090XV36C 9125957EL16XC1S036-230B TXV 35,000 16 13 CH33-48C EL296UH090XV48C 9125958EL16XC1S036-230B TXV 35,400 16 13 CH33-48C EL296UH110XE60C 9125959EL16XC1S036-230B TXV 35,200 16 13 CH33-48C EL296UH110XV48C 9125960EL16XC1S036-230B TXV 35,600 16 13 CH33-48C EL296UH110XV60C 9125961EL16XC1S036-230B TXV 35,600 16 13 CH33-48C SL280UH090V60C 9125962EL16XC1S036-230B TXV 35,600 16 13 CH33-48C SL280UH090XV60C 9125963EL16XC1S036-230B TXV 35,400 16 13 CH33-48C SL280UH110V60C 9125964EL16XC1S036-230B TXV 35,400 16 13 CH33-48C SL280UH110XV60C 9125965EL16XC1S036-230B TXV 35,200 16 13 CH33-48C SLP98UH090XV36C 9125966EL16XC1S036-230B TXV 35,000 16 13 CH33-48C SLP98UH090XV48C 9125967EL16XC1S036-230B TXV 35,600 16 13 CH33-48C SLP98UH110XV60C 9125968EL16XC1S036-230B TXV 34,600 14.5 12.2 CH33-48C 9125970EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL180UH090E60C 9125971EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL180UH110E60C 9125972EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL180UH110XE60C 9125973EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL195UH090XE48C 9125974EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL195UH110XE60C 9125975EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL296UH090XE48C 9125976EL16XC1S036-230B TXV 35,800 16 13 CH33-49 EL296UH090XV36C 9125977EL16XC1S036-230B TXV 35,600 16 13 CH33-49 EL296UH090XV48C 9125978EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL296UH110XE60C 9125979NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 125: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 125

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL296UH110XV48C 9125980EL16XC1S036-230B TXV 36,000 16 13 CH33-49 EL296UH110XV60C 9125981EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SL280UH090V60C 9125982EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SL280UH090XV60C 9125983EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SL280UH110V60C 9125984EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SL280UH110XV60C 9125985EL16XC1S036-230B TXV 35,800 16 13 CH33-49 SLP98UH090XV36C 9125986EL16XC1S036-230B TXV 35,600 16 13 CH33-49 SLP98UH090XV48C 9125987EL16XC1S036-230B TXV 36,000 16 13 CH33-49 SLP98UH110XV60C 9125988EL16XC1S036-230B TXV 35,200 15.1 12.2 CH33-49 9125990EL16XC1S036-230B TXV 35,800 16 13 CH33-50/60C EL180UH090E60C 9125991EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL180UH110E60C 9125992EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL180UH110XE60C 9125993EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL195UH090XE48C 9125994EL16XC1S036-230B TXV 35,800 16 13 CH33-50/60C EL195UH110XE60C 9125995EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL296UH090XE48C 9125996EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL296UH090XV36C 9125997EL16XC1S036-230B TXV 35,400 16 13 CH33-50/60C EL296UH090XV48C 9125998EL16XC1S036-230B TXV 35,800 16 13 CH33-50/60C EL296UH110XE60C 9125999EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C EL296UH110XV48C 9126000EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C EL296UH110XV60C 9126001EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SL280UH090V60C 9126002EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SL280UH090XV60C 9126003EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SL280UH110V60C 9126004EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SL280UH110XV60C 9126005EL16XC1S036-230B TXV 35,600 16 13 CH33-50/60C SLP98UH090XV36C 9126006EL16XC1S036-230B TXV 35,400 16 13 CH33-50/60C SLP98UH090XV48C 9126007EL16XC1S036-230B TXV 36,000 16 13 CH33-50/60C SLP98UH110XV60C 9126008EL16XC1S036-230B TXV 35,000 14.5 12.2 CH33-50/60C 9126010EL16XC1S036-230B TXV 34,600 15.1 12.5 CH35-30A EL180UH045E36A 9126011EL16XC1S036-230B TXV 34,600 15.1 12.5 CH35-30A EL180UH045XE36A 9126012EL16XC1S036-230B TXV 34,600 15.1 12.5 CH35-30A SL280UH070V36A 9126013EL16XC1S036-230B TXV 34,600 15.1 12.5 CH35-30A SL280UH070XV36A 9126014EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-30B EL180UH070E36B 9126015EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-30B EL180UH070XE36B 9126016EL16XC1S036-230B TXV 35,000 16 13 CH35-30B EL180UH090E48B 9126017EL16XC1S036-230B TXV 35,000 16 13 CH35-30B EL180UH090XE48B 9126018EL16XC1S036-230B TXV 34,800 15.1 12.5 CH35-30B EL195UH045XE36B 9126019EL16XC1S036-230B TXV 34,800 15.1 12.5 CH35-30B EL195UH070XE36B 9126020EL16XC1S036-230B TXV 34,800 15.1 12.5 CH35-30B EL296UH045XE36B 9126021EL16XC1S036-230B TXV 35,000 15.5 12.5 CH35-30B EL296UH045XV36B 9126022EL16XC1S036-230B TXV 34,800 15.1 12.5 CH35-30B EL296UH070XE36B 9126023EL16XC1S036-230B TXV 35,000 15.5 12.5 CH35-30B EL296UH070XV36B 9126024EL16XC1S036-230B TXV 35,200 16 13 CH35-30B SL280UH090V36B 9126025EL16XC1S036-230B TXV 35,200 16 13 CH35-30B SL280UH090V48B 9126026EL16XC1S036-230B TXV 35,200 16 13 CH35-30B SL280UH090XV48B 9126027EL16XC1S036-230B TXV 35,000 15.5 12.5 CH35-30B SLP98UH070XV36B 9126028EL16XC1S036-230B TXV 34,600 14.5 12.2 CH35-30B 9126029EL16XC1S036-230B TXV 33,200 14.5 12.2 CH35-36A EL180UH045E36A 9126030NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 126: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 126

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,200 14.5 12.2 CH35-36A EL180UH045XE36A 9126031EL16XC1S036-230B TXV 33,400 14.5 12.2 CH35-36A SL280UH070V36A 9126032EL16XC1S036-230B TXV 33,400 14.5 12.2 CH35-36A SL280UH070XV36A 9126033EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B EL180UH070E36B 9126034EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B EL180UH070XE36B 9126035EL16XC1S036-230B TXV 33,600 15.1 12.5 CH35-36B EL180UH090E48B 9126036EL16XC1S036-230B TXV 33,600 15.1 12.5 CH35-36B EL180UH090XE48B 9126037EL16XC1S036-230B TXV 33,000 15.1 12.2 CH35-36B EL195UH045XE36B 9126038EL16XC1S036-230B TXV 33,200 14.5 12 CH35-36B EL195UH070XE36B 9126447EL16XC1S036-230B TXV 33,000 15.1 12.2 CH35-36B EL296UH045XE36B 9126039EL16XC1S036-230B TXV 33,200 15.1 12.2 CH35-36B EL296UH045XV36B 9126040EL16XC1S036-230B TXV 33,200 14.5 12 CH35-36B EL296UH070XE36B 9126448EL16XC1S036-230B TXV 33,200 15.1 12.5 CH35-36B EL296UH070XV36B 9126041EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B SL280UH090V36B 9126042EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B SL280UH090V48B 9126043EL16XC1S036-230B TXV 33,600 15.5 12.5 CH35-36B SL280UH090XV48B 9126044EL16XC1S036-230B TXV 33,200 15.1 12.5 CH35-36B SLP98UH070XV36B 9126045EL16XC1S036-230B TXV 34,400 16 13 CH35-36C EL180UH090E60C 9126046EL16XC1S036-230B TXV 34,200 16 13 CH35-36C EL180UH110E60C 9126047EL16XC1S036-230B TXV 34,200 16 13 CH35-36C EL180UH110XE60C 9126048EL16XC1S036-230B TXV 34,200 15.5 12.5 CH35-36C EL195UH090XE48C 9126049EL16XC1S036-230B TXV 34,400 15.5 12.5 CH35-36C EL195UH110XE60C 9126050EL16XC1S036-230B TXV 34,200 15.5 12.5 CH35-36C EL296UH090XE48C 9126051EL16XC1S036-230B TXV 34,200 15.5 12.5 CH35-36C EL296UH090XV36C 9126052EL16XC1S036-230B TXV 34,000 15.5 12.5 CH35-36C EL296UH090XV48C 9126053EL16XC1S036-230B TXV 34,400 15.5 12.5 CH35-36C EL296UH110XE60C 9126054EL16XC1S036-230B TXV 34,200 16 13 CH35-36C EL296UH110XV48C 9126055EL16XC1S036-230B TXV 34,400 16 13 CH35-36C EL296UH110XV60C 9126056EL16XC1S036-230B TXV 34,600 16 13 CH35-36C SL280UH090V60C 9126057EL16XC1S036-230B TXV 34,600 16 13 CH35-36C SL280UH090XV60C 9126058EL16XC1S036-230B TXV 34,400 15.5 12.5 CH35-36C SL280UH110V60C 9126059EL16XC1S036-230B TXV 34,400 15.5 12.5 CH35-36C SL280UH110XV60C 9126060EL16XC1S036-230B TXV 34,200 15.5 12.5 CH35-36C SLP98UH090XV36C 9126061EL16XC1S036-230B TXV 34,000 15.5 12.5 CH35-36C SLP98UH090XV48C 9126062EL16XC1S036-230B TXV 34,400 16 13 CH35-36C SLP98UH110XV60C 9126063EL16XC1S036-230B TXV 36,000 16 13 CH35-42B EL180UH070E36B 9126064EL16XC1S036-230B TXV 36,000 16 13 CH35-42B EL180UH070XE36B 9126065EL16XC1S036-230B TXV 35,800 16 13 CH35-42B EL180UH090E48B 9126066EL16XC1S036-230B TXV 35,800 16 13 CH35-42B EL180UH090XE48B 9126067EL16XC1S036-230B TXV 35,600 15.5 12.5 CH35-42B EL195UH045XE36B 9126068EL16XC1S036-230B TXV 35,600 15.5 12.5 CH35-42B EL195UH070XE36B 9126069EL16XC1S036-230B TXV 35,600 15.5 12.5 CH35-42B EL296UH045XE36B 9126070EL16XC1S036-230B TXV 35,800 16 13 CH35-42B EL296UH045XV36B 9126071EL16XC1S036-230B TXV 35,600 15.5 12.5 CH35-42B EL296UH070XE36B 9126072EL16XC1S036-230B TXV 35,800 16 13 CH35-42B EL296UH070XV36B 9126073EL16XC1S036-230B TXV 36,000 16 13 CH35-42B SL280UH090V36B 9126074EL16XC1S036-230B TXV 36,000 16 13 CH35-42B SL280UH090V48B 9126075EL16XC1S036-230B TXV 36,000 16 13 CH35-42B SL280UH090XV48B 9126076EL16XC1S036-230B TXV 35,800 16 13 CH35-42B SLP98UH070XV36B 9126077NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 127: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 127

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,400 15.1 12.5 CH35-42B 9126078EL16XC1S036-230B TXV 35,800 16 13 CH35-42C EL180UH090E60C 9126079EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL180UH110E60C 9126080EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL180UH110XE60C 9126081EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL195UH090XE48C 9126082EL16XC1S036-230B TXV 35,600 16 13 CH35-42C EL195UH110XE60C 9126083EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL296UH090XE48C 9126084EL16XC1S036-230B TXV 35,600 16 13 CH35-42C EL296UH090XV36C 9126085EL16XC1S036-230B TXV 35,400 16 13 CH35-42C EL296UH090XV48C 9126086EL16XC1S036-230B TXV 35,600 16 13 CH35-42C EL296UH110XE60C 9126087EL16XC1S036-230B TXV 35,600 16 13 CH35-42C EL296UH110XV48C 9126088EL16XC1S036-230B TXV 35,800 16 13 CH35-42C EL296UH110XV60C 9126089EL16XC1S036-230B TXV 36,000 16 13 CH35-42C SL280UH090V60C 9126090EL16XC1S036-230B TXV 36,000 16 13 CH35-42C SL280UH090XV60C 9126091EL16XC1S036-230B TXV 35,800 16 13 CH35-42C SL280UH110V60C 9126092EL16XC1S036-230B TXV 35,800 16 13 CH35-42C SL280UH110XV60C 9126093EL16XC1S036-230B TXV 35,600 16 13 CH35-42C SLP98UH090XV36C 9126094EL16XC1S036-230B TXV 35,400 16 13 CH35-42C SLP98UH090XV48C 9126095EL16XC1S036-230B TXV 35,800 16 13 CH35-42C SLP98UH110XV60C 9126096EL16XC1S036-230B TXV 35,000 14.5 12.2 CH35-42C 9126097EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-48B EL180UH070E36B 9126098EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-48B EL180UH070XE36B 9126099EL16XC1S036-230B TXV 35,000 16 13 CH35-48B EL180UH090E48B 9126100EL16XC1S036-230B TXV 35,000 16 13 CH35-48B EL180UH090XE48B 9126101EL16XC1S036-230B TXV 35,000 15.1 12.5 CH35-48B EL195UH045XE36B 9126102EL16XC1S036-230B TXV 35,000 15.1 12.5 CH35-48B EL195UH070XE36B 9126103EL16XC1S036-230B TXV 35,000 15.1 12.5 CH35-48B EL296UH045XE36B 9126104EL16XC1S036-230B TXV 35,000 15.5 12.5 CH35-48B EL296UH045XV36B 9126105EL16XC1S036-230B TXV 35,000 15.1 12.5 CH35-48B EL296UH070XE36B 9126106EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-48B EL296UH070XV36B 9126107EL16XC1S036-230B TXV 35,200 16 13 CH35-48B SL280UH090V36B 9126108EL16XC1S036-230B TXV 35,200 16 13 CH35-48B SL280UH090V48B 9126109EL16XC1S036-230B TXV 35,200 16 13 CH35-48B SL280UH090XV48B 9126110EL16XC1S036-230B TXV 35,200 15.5 12.5 CH35-48B SLP98UH070XV36B 9126111EL16XC1S036-230B TXV 34,800 14.5 12.2 CH35-48B 9126112EL16XC1S036-230B TXV 35,600 16 13 CH35-48C EL180UH090E60C 9126113EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL180UH110E60C 9126114EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL180UH110XE60C 9126115EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL195UH090XE48C 9126116EL16XC1S036-230B TXV 35,600 16 13 CH35-48C EL195UH110XE60C 9126117EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL296UH090XE48C 9126118EL16XC1S036-230B TXV 35,400 16 13 CH35-48C EL296UH090XV36C 9126119EL16XC1S036-230B TXV 35,200 16 13 CH35-48C EL296UH090XV48C 9126120EL16XC1S036-230B TXV 35,600 16 13 CH35-48C EL296UH110XE60C 9126121EL16XC1S036-230B TXV 35,400 16 13 CH35-48C EL296UH110XV48C 9126122EL16XC1S036-230B TXV 35,600 16 13 CH35-48C EL296UH110XV60C 9126123EL16XC1S036-230B TXV 35,800 16 13 CH35-48C SL280UH090V60C 9126124EL16XC1S036-230B TXV 35,800 16 13 CH35-48C SL280UH090XV60C 9126125EL16XC1S036-230B TXV 35,600 16 13 CH35-48C SL280UH110V60C 9126126NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 128: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 128

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,600 16 13 CH35-48C SL280UH110XV60C 9126127EL16XC1S036-230B TXV 35,400 16 13 CH35-48C SLP98UH090XV36C 9126128EL16XC1S036-230B TXV 35,200 16 13 CH35-48C SLP98UH090XV48C 9126129EL16XC1S036-230B TXV 35,600 16 13 CH35-48C SLP98UH110XV60C 9126130EL16XC1S036-230B TXV 34,800 14.5 12.2 CH35-48C 9126131EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL180UH090E60C 9126132EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL180UH110E60C 9126133EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL180UH110XE60C 9126134EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL195UH090XE48C 9126135EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL195UH110XE60C 9126136EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL296UH090XE48C 9126137EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL296UH090XV36C 9126138EL16XC1S036-230B TXV 35,800 16 13 CH35-51C EL296UH090XV48C 9126139EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL296UH110XE60C 9126140EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL296UH110XV48C 9126141EL16XC1S036-230B TXV 36,000 16 13 CH35-51C EL296UH110XV60C 9126142EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SL280UH090V60C 9126143EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SL280UH090XV60C 9126144EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SL280UH110V60C 9126145EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SL280UH110XV60C 9126146EL16XC1S036-230B TXV 35,800 16 13 CH35-51C SLP98UH090XV36C 9126147EL16XC1S036-230B TXV 35,800 16 13 CH35-51C SLP98UH090XV48C 9126148EL16XC1S036-230B TXV 36,000 16 13 CH35-51C SLP98UH110XV60C 9126149EL16XC1S036-230B TXV 35,200 15.1 12.2 CH35-51C 9126150EL16XC1S036-230B TXV 34,000 15.1 12.2 CR33-30/36A EL180DF045E36A 9126151EL16XC1S036-230B TXV 33,800 15.1 12.5 CR33-30/36A SL280DF070V36A 9126152EL16XC1S036-230B TXV 33,800 15.5 12.5 CR33-30/36B EL180DF070E36B 9126153EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36B EL180DF090E48B 9126154EL16XC1S036-230B TXV 33,800 14.5 12.2 CR33-30/36B EL195DF045XE36B 9126155EL16XC1S036-230B TXV 33,800 15.1 12.5 CR33-30/36B EL195DF070XE48B 9126156EL16XC1S036-230B TXV 33,800 14.5 12.2 CR33-30/36B EL296DF045XE36B 9126157EL16XC1S036-230B TXV 33,800 15.1 12.2 CR33-30/36B EL296DF045XV36B 9126158EL16XC1S036-230B TXV 33,800 15.1 12.5 CR33-30/36B EL296DF070XE48B 9126159EL16XC1S036-230B TXV 33,800 14.5 12.2 CR33-30/36B EL296DF070XV48B 9126160EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36B SL280DF090V48B 9126161EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-30/36B SLP98DF070XV36B 9126162EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL180DF110E60C 9126163EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL195DF090XE48C 9126164EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL195DF110XE60C 9126165EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL296DF090XE48C 9126166EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-30/36C EL296DF090XV60C 9126167EL16XC1S036-230B TXV 34,000 15.5 12.5 CR33-30/36C EL296DF110XE60C 9126168EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-30/36C EL296DF110XV60C 9126169EL16XC1S036-230B TXV 34,200 15.5 12.5 CR33-30/36C SL280DF110V60C 9126170EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-30/36C SLP98DF090XV36C 9126171EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-30/36C SLP98DF090XV48C 9126172EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-30/36C SLP98DF090XV60C 9126173EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-30/36C SLP98DF110XV60C 9126174EL16XC1S036-230B TXV 34,200 16 13 CR33-48B EL180DF070E36B 9126175NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 129: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 129

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,400 16 13 CR33-48B EL180DF090E48B 9126176EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-48B EL195DF045XE36B 9126177EL16XC1S036-230B TXV 34,200 15.5 12.5 CR33-48B EL195DF070XE48B 9126178EL16XC1S036-230B TXV 34,000 15.1 12.5 CR33-48B EL296DF045XE36B 9126179EL16XC1S036-230B TXV 34,200 15.1 12.5 CR33-48B EL296DF045XV36B 9126180EL16XC1S036-230B TXV 34,200 15.5 12.5 CR33-48B EL296DF070XE48B 9126181EL16XC1S036-230B TXV 34,400 15.1 12.5 CR33-48B EL296DF070XV48B 9126182EL16XC1S036-230B TXV 34,400 15.5 12.5 CR33-48B SL280DF090V48B 9126183EL16XC1S036-230B TXV 34,200 15.5 12.5 CR33-48B SLP98DF070XV36B 9126184EL16XC1S036-230B TXV 33,800 14.5 12 CR33-48B 10238959EL16XC1S036-230B TXV 34,800 16 13 CR33-48C EL180DF110E60C 9126185EL16XC1S036-230B TXV 34,600 16 13 CR33-48C EL195DF090XE48C 9126186EL16XC1S036-230B TXV 34,600 16 13 CR33-48C EL195DF110XE60C 9126187EL16XC1S036-230B TXV 34,600 16 13 CR33-48C EL296DF090XE48C 9126188EL16XC1S036-230B TXV 34,600 15.5 12.5 CR33-48C EL296DF090XV60C 9126189EL16XC1S036-230B TXV 34,600 16 13 CR33-48C EL296DF110XE60C 9126190EL16XC1S036-230B TXV 34,600 15.5 12.5 CR33-48C EL296DF110XV60C 9126191EL16XC1S036-230B TXV 34,600 16 13 CR33-48C SL280DF110V60C 9126192EL16XC1S036-230B TXV 34,400 15.5 12.5 CR33-48C SLP98DF090XV36C 9126193EL16XC1S036-230B TXV 34,200 16 13 CR33-48C SLP98DF090XV48C 9126194EL16XC1S036-230B TXV 34,600 15.5 12.5 CR33-48C SLP98DF090XV60C 9126195EL16XC1S036-230B TXV 34,600 15.5 12.5 CR33-48C SLP98DF110XV60C 9126196EL16XC1S036-230B TXV 33,800 14.5 12 CR33-48C 10238960EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-31A EL180UH045E36A 9126197EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-31A EL180UH045XE36A 9126198EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31A SL280UH070V36A 9126199EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31A SL280UH070XV36A 9126200EL16XC1S036-230B TXV 34,200 14.5 12 CX34-31A 9126449EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31B EL180UH070E36B 9126201EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31B EL180UH070XE36B 9126202EL16XC1S036-230B TXV 34,400 15.5 12.5 CX34-31B EL180UH090E48B 9126203EL16XC1S036-230B TXV 34,400 15.5 12.5 CX34-31B EL180UH090XE48B 9126204EL16XC1S036-230B TXV 34,400 14.5 12.2 CX34-31B EL195UH045XE36B 9126205EL16XC1S036-230B TXV 34,200 15.1 12.5 CX34-31B EL195UH070XE36B 9126206EL16XC1S036-230B TXV 34,400 14.5 12.2 CX34-31B EL296UH045XE36B 9126207EL16XC1S036-230B TXV 34,400 15.1 12.5 CX34-31B EL296UH045XV36B 9126208EL16XC1S036-230B TXV 34,200 15.1 12.5 CX34-31B EL296UH070XE36B 9126209EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31B EL296UH070XV36B 9126210EL16XC1S036-230B TXV 34,600 16 13 CX34-31B SL280UH090V36B 9126211EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-31B SL280UH090V48B 9126212EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-31B SL280UH090XV48B 9126213EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-31B SLP98UH070XV36B 9126214EL16XC1S036-230B TXV 34,200 14.5 12 CX34-31B 9126450EL16XC1S036-230B TXV 33,600 14.5 12.2 CX34-36A EL180UH045E36A 9126215EL16XC1S036-230B TXV 33,600 14.5 12.2 CX34-36A EL180UH045XE36A 9126216EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-36A SL280UH070V36A 9126217EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-36A SL280UH070XV36A 9126218EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36B EL180UH070E36B 9126219EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36B EL180UH070XE36B 9126220NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 130: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 130

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36B EL180UH090E48B 9126221EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36B EL180UH090XE48B 9126222EL16XC1S036-230B TXV 33,000 15.1 12.2 CX34-36B EL195UH045XE36B 9126223EL16XC1S036-230B TXV 33,400 15.1 12.5 CX34-36B EL195UH070XE36B 9126224EL16XC1S036-230B TXV 33,000 15.1 12.2 CX34-36B EL296UH045XE36B 9126225EL16XC1S036-230B TXV 33,000 14.5 12.2 CX34-36B EL296UH045XV36B 9126226EL16XC1S036-230B TXV 33,400 15.1 12.5 CX34-36B EL296UH070XE36B 9126227EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-36B EL296UH070XV36B 9126228EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36B SL280UH090V36B 9126229EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36B SL280UH090V48B 9126230EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36B SL280UH090XV48B 9126231EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-36B SLP98UH070XV36B 9126232EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36C EL180UH090E60C 9126233EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36C EL180UH110E60C 9126234EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36C EL180UH110XE60C 9126235EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36C EL195UH090XE48C 9126236EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36C EL195UH110XE60C 9126237EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36C EL296UH090XE48C 9126238EL16XC1S036-230B TXV 33,600 15.1 12.5 CX34-36C EL296UH090XV36C 9126239EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36C EL296UH090XV48C 9126240EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-36C EL296UH110XE60C 9126241EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-36C EL296UH110XV48C 9126242EL16XC1S036-230B TXV 33,600 15.1 12.5 CX34-36C SLP98UH090XV36C 9126243EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-36C SLP98UH090XV48C 9126244EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38A EL180UH045E36A 9126245EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38A EL180UH045XE36A 9126246EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38A SL280UH070V36A 9126247EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38A SL280UH070XV36A 9126248EL16XC1S036-230B TXV 34,600 14.5 12.2 CX34-38A 9126249EL16XC1S036-230B TXV 34,800 16 13 CX34-38B EL180UH070E36B 9126250EL16XC1S036-230B TXV 34,800 16 13 CX34-38B EL180UH070XE36B 9126251EL16XC1S036-230B TXV 35,200 16 13 CX34-38B EL180UH090E48B 9126252EL16XC1S036-230B TXV 35,200 16 13 CX34-38B EL180UH090XE48B 9126253EL16XC1S036-230B TXV 34,800 15.1 12.5 CX34-38B EL195UH045XE36B 9126254EL16XC1S036-230B TXV 34,800 15.5 12.5 CX34-38B EL195UH070XE36B 9126255EL16XC1S036-230B TXV 34,800 15.1 12.5 CX34-38B EL296UH045XE36B 9126256EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38B EL296UH045XV36B 9126257EL16XC1S036-230B TXV 34,800 15.5 12.5 CX34-38B EL296UH070XE36B 9126258EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38B EL296UH070XV36B 9126259EL16XC1S036-230B TXV 35,000 16 13 CX34-38B SL280UH090V36B 9126260EL16XC1S036-230B TXV 35,200 16 13 CX34-38B SL280UH090V48B 9126261EL16XC1S036-230B TXV 35,200 16 13 CX34-38B SL280UH090XV48B 9126262EL16XC1S036-230B TXV 35,000 15.5 12.5 CX34-38B SLP98UH070XV36B 9126263EL16XC1S036-230B TXV 34,600 14.5 12.2 CX34-38B 9126264EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-42 EL180UH070E36B 9126265EL16XC1S036-230B TXV 33,400 15.5 12.5 CX34-42 EL180UH070XE36B 9126266EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-42 EL180UH090E48B 9126267EL16XC1S036-230B TXV 33,800 15.5 12.5 CX34-42 EL180UH090XE48B 9126268EL16XC1S036-230B TXV 33,000 15.1 12.2 CX34-42 EL195UH045XE36B 9126269NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 131: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 131

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 33,400 15.1 12.5 CX34-42 EL195UH070XE36B 9126270EL16XC1S036-230B TXV 33,000 15.1 12.2 CX34-42 EL296UH045XE36B 9126271EL16XC1S036-230B TXV 33,400 14.5 12.2 CX34-42 EL296UH045XV36B 9126272EL16XC1S036-230B TXV 33,400 15.1 12.5 CX34-42 EL296UH070XE36B 9126273EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-42 EL296UH070XV36B 9126274EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-42 SL280UH090V36B 9126275EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-42 SL280UH090V48B 9126276EL16XC1S036-230B TXV 33,600 15.5 12.5 CX34-42 SL280UH090XV48B 9126277EL16XC1S036-230B TXV 33,200 15.1 12.5 CX34-42 SLP98UH070XV36B 9126278EL16XC1S036-230B TXV 35,200 16 13 CX34-43B EL180UH070E36B 9126279EL16XC1S036-230B TXV 35,200 16 13 CX34-43B EL180UH070XE36B 9126280EL16XC1S036-230B TXV 35,600 16 13 CX34-43B EL180UH090E48B 9126281EL16XC1S036-230B TXV 35,600 16 13 CX34-43B EL180UH090XE48B 9126282EL16XC1S036-230B TXV 35,000 15.1 12.5 CX34-43B EL195UH045XE36B 9126283EL16XC1S036-230B TXV 35,000 16 13 CX34-43B EL195UH070XE36B 9126284EL16XC1S036-230B TXV 35,000 15.1 12.5 CX34-43B EL296UH045XE36B 9126285EL16XC1S036-230B TXV 35,200 15.5 12.5 CX34-43B EL296UH045XV36B 9126286EL16XC1S036-230B TXV 35,000 16 13 CX34-43B EL296UH070XE36B 9126287EL16XC1S036-230B TXV 35,200 15.5 12.5 CX34-43B EL296UH070XV36B 9126288EL16XC1S036-230B TXV 35,200 16 13 CX34-43B SL280UH090V36B 9126289EL16XC1S036-230B TXV 35,400 16 13 CX34-43B SL280UH090V48B 9126290EL16XC1S036-230B TXV 35,400 16 13 CX34-43B SL280UH090XV48B 9126291EL16XC1S036-230B TXV 35,200 15.5 12.5 CX34-43B SLP98UH070XV36B 9126292EL16XC1S036-230B TXV 34,800 14.5 12.2 CX34-43B 9126293EL16XC1S036-230B TXV 35,600 16 13 CX34-43C EL180UH090E60C 9126294EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL180UH110E60C 9126295EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL180UH110XE60C 9126296EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL195UH090XE48C 9126297EL16XC1S036-230B TXV 35,600 16 13 CX34-43C EL195UH110XE60C 9126298EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL296UH090XE48C 9126299EL16XC1S036-230B TXV 35,400 16 13 CX34-43C EL296UH090XV36C 9126300EL16XC1S036-230B TXV 35,200 16 13 CX34-43C EL296UH090XV48C 9126301EL16XC1S036-230B TXV 35,600 16 13 CX34-43C EL296UH110XE60C 9126302EL16XC1S036-230B TXV 35,400 16 13 CX34-43C EL296UH110XV48C 9126303EL16XC1S036-230B TXV 35,600 16 13 CX34-43C EL296UH110XV60C 9126304EL16XC1S036-230B TXV 35,800 16 13 CX34-43C SL280UH090V60C 9126305EL16XC1S036-230B TXV 35,800 16 13 CX34-43C SL280UH090XV60C 9126306EL16XC1S036-230B TXV 35,600 16 13 CX34-43C SL280UH110V60C 9126307EL16XC1S036-230B TXV 35,600 16 13 CX34-43C SL280UH110XV60C 9126308EL16XC1S036-230B TXV 35,400 16 13 CX34-43C SLP98UH090XV36C 9126309EL16XC1S036-230B TXV 35,200 16 13 CX34-43C SLP98UH090XV48C 9126310EL16XC1S036-230B TXV 35,600 16 13 CX34-43C SLP98UH110XV60C 9126311EL16XC1S036-230B TXV 34,800 14.5 12.2 CX34-43C 9126312EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48B EL180UH070E36B 9126313EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48B EL180UH070XE36B 9126314EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48B EL180UH090E48B 9126315EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48B EL180UH090XE48B 9126316EL16XC1S036-230B TXV 34,200 15.5 12.5 CX34-44/48B EL195UH045XE36B 9126317EL16XC1S036-230B TXV 34,400 15.5 12.5 CX34-44/48B EL195UH070XE36B 9126318NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 132: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 132

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,200 15.5 12.5 CX34-44/48B EL296UH045XE36B 9126319EL16XC1S036-230B TXV 34,600 15.1 12.5 CX34-44/48B EL296UH045XV36B 9126320EL16XC1S036-230B TXV 34,400 15.5 12.5 CX34-44/48B EL296UH070XE36B 9126321EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-44/48B EL296UH070XV36B 9126322EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48B SL280UH090V36B 9126323EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48B SL280UH090V48B 9126324EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48B SL280UH090XV48B 9126325EL16XC1S036-230B TXV 34,600 15.5 12.5 CX34-44/48B SLP98UH070XV36B 9126326EL16XC1S036-230B TXV 34,200 14.5 12 CX34-44/48B 9126451EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C EL180UH090E60C 9126327EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL180UH110E60C 9126328EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL180UH110XE60C 9126329EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL195UH090XE48C 9126330EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C EL195UH110XE60C 9126331EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL296UH090XE48C 9126332EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48C EL296UH090XV36C 9126333EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C EL296UH090XV48C 9126334EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C EL296UH110XE60C 9126335EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48C EL296UH110XV48C 9126336EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C EL296UH110XV60C 9126337EL16XC1S036-230B TXV 35,200 16 13 CX34-44/48C SL280UH090V60C 9126338EL16XC1S036-230B TXV 35,200 16 13 CX34-44/48C SL280UH090XV60C 9126339EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C SL280UH110V60C 9126340EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C SL280UH110XV60C 9126341EL16XC1S036-230B TXV 34,800 16 13 CX34-44/48C SLP98UH090XV36C 9126342EL16XC1S036-230B TXV 34,600 16 13 CX34-44/48C SLP98UH090XV48C 9126343EL16XC1S036-230B TXV 35,000 16 13 CX34-44/48C SLP98UH110XV60C 9126344EL16XC1S036-230B TXV 34,200 14.5 12 CX34-44/48C 9126452EL16XC1S036-230B TXV 35,800 16 13 CX34-49 EL180UH090E60C 9126345EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL180UH110E60C 9126346EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL180UH110XE60C 9126347EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL195UH090XE48C 9126348EL16XC1S036-230B TXV 36,000 16 13 CX34-49 EL195UH110XE60C 9126349EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL296UH090XE48C 9126350EL16XC1S036-230B TXV 35,800 16 13 CX34-49 EL296UH090XV36C 9126351EL16XC1S036-230B TXV 35,600 16 13 CX34-49 EL296UH090XV48C 9126352EL16XC1S036-230B TXV 36,000 16 13 CX34-49 EL296UH110XE60C 9126353EL16XC1S036-230B TXV 35,800 16 13 CX34-49 EL296UH110XV48C 9126354EL16XC1S036-230B TXV 36,000 16 13 CX34-49 EL296UH110XV60C 9126355EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SL280UH090V60C 9126356EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SL280UH090XV60C 9126357EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SL280UH110V60C 9126358EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SL280UH110XV60C 9126359EL16XC1S036-230B TXV 35,800 16 13 CX34-49 SLP98UH090XV36C 9126360EL16XC1S036-230B TXV 35,600 16 13 CX34-49 SLP98UH090XV48C 9126361EL16XC1S036-230B TXV 36,000 16 13 CX34-49 SLP98UH110XV60C 9126362EL16XC1S036-230B TXV 35,200 14.5 12.2 CX34-49 9126363NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 133: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 133

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C EL180UH090E60C 9126364EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL180UH110E60C 9126365EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL180UH110XE60C 9126366EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL195UH090XE48C 9126367EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C EL195UH110XE60C 9126368EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL296UH090XE48C 9126369EL16XC1S036-230B TXV 35,200 16 13 CX34-50/60C EL296UH090XV36C 9126370EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C EL296UH090XV48C 9126371EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C EL296UH110XE60C 9126372EL16XC1S036-230B TXV 35,200 16 13 CX34-50/60C EL296UH110XV48C 9126373EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C EL296UH110XV60C 9126374EL16XC1S036-230B TXV 35,600 16 13 CX34-50/60C SL280UH090V60C 9126375EL16XC1S036-230B TXV 35,600 16 13 CX34-50/60C SL280UH090XV60C 9126376EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C SL280UH110V60C 9126377EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C SL280UH110XV60C 9126378EL16XC1S036-230B TXV 35,200 16 13 CX34-50/60C SLP98UH090XV36C 9126379EL16XC1S036-230B TXV 35,000 16 13 CX34-50/60C SLP98UH090XV48C 9126380EL16XC1S036-230B TXV 35,400 16 13 CX34-50/60C SLP98UH110XV60C 9126381EL16XC1S036-230B TXV 34,600 14.5 12.2 CX34-50/60C 9126382EL16XC1S036-230B TXV 33,600 15.1 12.2 CX35-30/36A EL180UH045E36A 9126383EL16XC1S036-230B TXV 33,600 15.1 12.2 CX35-30/36A EL180UH045XE36A 9126384EL16XC1S036-230B TXV 33,400 15.1 12.5 CX35-30/36A SL280UH070V36A 9126385EL16XC1S036-230B TXV 33,400 15.1 12.5 CX35-30/36A SL280UH070XV36A 9126386EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36B EL180UH070E36B 9126387EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36B EL180UH070XE36B 9126388EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36B EL180UH090E48B 9126389EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36B EL180UH090XE48B 9126390EL16XC1S036-230B TXV 33,200 15.1 12.5 CX35-30/36B EL195UH045XE36B 9126391EL16XC1S036-230B TXV 33,200 15.1 12.5 CX35-30/36B EL296UH045XE36B 9126392EL16XC1S036-230B TXV 33,200 15.1 12.2 CX35-30/36B EL296UH045XV36B 9126393EL16XC1S036-230B TXV 33,400 15.1 12.5 CX35-30/36B EL296UH070XV36B 9126394EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36B SL280UH090V36B 9126395EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36B SL280UH090V48B 9126396EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36B SL280UH090XV48B 9126397EL16XC1S036-230B TXV 33,400 15.1 12.5 CX35-30/36B SLP98UH070XV36B 9126398EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36C EL180UH090E60C 9126399EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL180UH110E60C 9126400EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL180UH110XE60C 9126401EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL195UH090XE48C 9126402EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36C EL195UH110XE60C 9126403EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL296UH090XE48C 9126404EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36C EL296UH090XV36C 9126405EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C EL296UH090XV48C 9126406EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36C EL296UH110XE60C 9126407EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36C EL296UH110XV48C 9126408EL16XC1S036-230B TXV 33,800 15.5 12.5 CX35-30/36C SLP98UH090XV36C 9126409EL16XC1S036-230B TXV 33,600 15.5 12.5 CX35-30/36C SLP98UH090XV48C 9126410EL16XC1S036-230B TXV 34,000 15.5 12.5 CX35-30/36C SLP98UH110XV60C 9126411EL16XC1S036-230B TXV 34,800 15.5 12.5 CX35-30A EL180UH045E36A 9126412NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 134: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 134

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 34,800 15.5 12.5 CX35-30A EL180UH045XE36A 9126413EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30A SL280UH070V36A 9126414EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30A SL280UH070XV36A 9126415EL16XC1S036-230B TXV 34,400 16 13 CX35-30B EL180UH070E36B 9126416EL16XC1S036-230B TXV 34,400 16 13 CX35-30B EL180UH070XE36B 9126417EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30B EL180UH090E48B 9126418EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30B EL180UH090XE48B 9126419EL16XC1S036-230B TXV 34,400 14.5 12.2 CX35-30B EL195UH045XE36B 9126420EL16XC1S036-230B TXV 34,400 15.5 12.5 CX35-30B EL195UH070XE36B 9126421EL16XC1S036-230B TXV 34,400 14.5 12.2 CX35-30B EL296UH045XE36B 9126422EL16XC1S036-230B TXV 34,600 15.1 12.5 CX35-30B EL296UH045XV36B 9126423EL16XC1S036-230B TXV 34,400 15.5 12.5 CX35-30B EL296UH070XE36B 9126424EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30B EL296UH070XV36B 9126425EL16XC1S036-230B TXV 34,800 16 13 CX35-30B SL280UH090V36B 9126426EL16XC1S036-230B TXV 34,800 16 13 CX35-30B SL280UH090V48B 9126427EL16XC1S036-230B TXV 34,800 16 13 CX35-30B SL280UH090XV48B 9126428EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-30B SLP98UH070XV36B 9126429EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-36A EL180UH045E36A 9126430EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-36A EL180UH045XE36A 9126431EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36A SL280UH070V36A 9126432EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36A SL280UH070XV36A 9126433EL16XC1S036-230B TXV 34,600 14.5 12.2 CX35-36A 9126434EL16XC1S036-230B TXV 35,000 16 13 CX35-36B EL180UH070E36B 9126435EL16XC1S036-230B TXV 35,000 16 13 CX35-36B EL180UH070XE36B 9126436EL16XC1S036-230B TXV 35,400 16 13 CX35-36B EL180UH090E48B 9126437EL16XC1S036-230B TXV 35,400 16 13 CX35-36B EL180UH090XE48B 9126438EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-36B EL195UH045XE36B 10150019EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B EL195UH070XE36B 10150020EL16XC1S036-230B TXV 34,600 15.5 12.5 CX35-36B EL296UH045XE36B 10150021EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B EL296UH045XV36B 10150022EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B EL296UH070XE36B 10150023EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B EL296UH070XV36B 10150024EL16XC1S036-230B TXV 35,200 16 13 CX35-36B SL280UH090V36B 10150025EL16XC1S036-230B TXV 35,200 16 13 CX35-36B SL280UH090V48B 10150026EL16XC1S036-230B TXV 35,200 16 13 CX35-36B SL280UH090XV48B 10150027EL16XC1S036-230B TXV 35,000 15.5 12.5 CX35-36B SLP98UH070XV36B 10150028EL16XC1S036-230B TXV 34,600 14.5 12.2 CX35-36B 10298951EL16XC1S036-230B TXV 35,200 16 13 CX35-48B EL180UH070E36B 10150030EL16XC1S036-230B TXV 35,200 16 13 CX35-48B EL180UH070XE36B 10150031EL16XC1S036-230B TXV 35,600 16 13 CX35-48B EL180UH090E48B 10150032EL16XC1S036-230B TXV 35,600 16 13 CX35-48B EL180UH090XE48B 10150033EL16XC1S036-230B TXV 34,800 15.5 12.5 CX35-48B EL195UH045XE36B 10150034EL16XC1S036-230B TXV 35,200 16 13 CX35-48B EL195UH070XE36B 10150035EL16XC1S036-230B TXV 34,800 15.5 12.5 CX35-48B EL296UH045XE36B 10150036EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-48B EL296UH045XV36B 10150037EL16XC1S036-230B TXV 35,200 16 13 CX35-48B EL296UH070XE36B 10150038EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-48B EL296UH070XV36B 10150039EL16XC1S036-230B TXV 35,400 16 13 CX35-48B SL280UH090V36B 10150040NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 135: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 135

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,400 16 13 CX35-48B SL280UH090V48B 10150041EL16XC1S036-230B TXV 35,400 16 13 CX35-48B SL280UH090XV48B 10150042EL16XC1S036-230B TXV 35,200 15.5 12.5 CX35-48B SLP98UH070XV36B 10150043EL16XC1S036-230B TXV 34,800 14.5 12.2 CX35-48B 10150029EL16XC1S036-230B TXV 35,600 16 13 CX35-48C EL180UH090E60C 10150045EL16XC1S036-230B TXV 35,200 16 13 CX35-48C EL180UH110E60C 10150046EL16XC1S036-230B TXV 35,200 16 13 CX35-48C EL180UH110XE60C 10150047EL16XC1S036-230B TXV 35,400 16 13 CX35-48C EL195UH090XE48C 10150048EL16XC1S036-230B TXV 35,600 16 13 CX35-48C EL195UH110XE60C 10150049EL16XC1S036-230B TXV 35,400 16 13 CX35-48C EL296UH090XE48C 10150050EL16XC1S036-230B TXV 35,400 16 13 CX35-48C EL296UH090XV36C 10150051EL16XC1S036-230B TXV 35,200 16 13 CX35-48C EL296UH090XV48C 10150052EL16XC1S036-230B TXV 35,600 16 13 CX35-48C EL296UH110XE60C 10150053EL16XC1S036-230B TXV 35,400 16 13 CX35-48C EL296UH110XV48C 10150054EL16XC1S036-230B TXV 35,800 16 13 CX35-48C EL296UH110XV60C 10150055EL16XC1S036-230B TXV 35,800 16 13 CX35-48C SL280UH090V60C 10150056EL16XC1S036-230B TXV 35,800 16 13 CX35-48C SL280UH090XV60C 10150057EL16XC1S036-230B TXV 35,600 16 13 CX35-48C SL280UH110V60C 10150058EL16XC1S036-230B TXV 35,600 16 13 CX35-48C SL280UH110XV60C 10150059EL16XC1S036-230B TXV 35,400 16 13 CX35-48C SLP98UH090XV36C 10150060EL16XC1S036-230B TXV 35,200 16 13 CX35-48C SLP98UH090XV48C 10150061EL16XC1S036-230B TXV 35,800 16 13 CX35-48C SLP98UH110XV60C 10150062EL16XC1S036-230B TXV 34,800 14.5 12.2 CX35-48C 10150044EL16XC1S036-230B TXV 36,000 16 13 CX35-49C EL180UH090E60C 10150064EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL180UH110E60C 10150065EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL180UH110XE60C 10150066EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL195UH090XE48C 10150067EL16XC1S036-230B TXV 36,000 16 13 CX35-49C EL195UH110XE60C 10150068EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL296UH090XE48C 10150069EL16XC1S036-230B TXV 35,800 16 13 CX35-49C EL296UH090XV36C 10150070EL16XC1S036-230B TXV 35,600 16 13 CX35-49C EL296UH090XV48C 10150071EL16XC1S036-230B TXV 36,000 16 13 CX35-49C EL296UH110XE60C 10150072EL16XC1S036-230B TXV 35,800 16 13 CX35-49C EL296UH110XV48C 10150073EL16XC1S036-230B TXV 36,000 16 13 CX35-49C EL296UH110XV60C 10150074EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SL280UH090V60C 10150075EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SL280UH090XV60C 10150076EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SL280UH110V60C 10150077EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SL280UH110XV60C 10150078EL16XC1S036-230B TXV 35,800 16 13 CX35-49C SLP98UH090XV36C 10150079EL16XC1S036-230B TXV 35,600 16 13 CX35-49C SLP98UH090XV48C 10150080EL16XC1S036-230B TXV 36,000 16 13 CX35-49C SLP98UH110XV60C 10150081EL16XC1S036-230B TXV 35,200 14.5 12.2 CX35-49C 10150063EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C EL180UH090E60C 10150083EL16XC1S036-230B TXV 35,000 16 13 CX35-50/60C EL180UH110E60C 10150084EL16XC1S036-230B TXV 35,000 16 13 CX35-50/60C EL180UH110XE60C 10150085EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C EL195UH090XE48C 10150086EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C EL195UH110XE60C 10150087EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C EL296UH090XE48C 10150088EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C EL296UH090XV36C 10150089NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

Page 136: 1.5-5 TON AIR CONDITIONERS AIR ... - InspectAPedia.com · Air conditioners and components within bonded for ... Fan motor has sleeve bearings and is inherently ... Single-phase units

EL16XC1 - 1.5 to 5 Ton Air Conditioner / Page 136

AHRI SYSTEM MATCHES - SOUTHWEST REGION - 036NOTE - For the latest up-to-date system matches please visit the AHRI web site at http://www.ahridirectory.orgModel No.

Expansion Device Capacity SEER EER Coil or

Air Handler Furnace AHRI Reference

EL16XC1S036-230B TXV 35,000 16 13 CX35-50/60C EL296UH090XV48C 10150090EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C EL296UH110XE60C 10150091EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C EL296UH110XV48C 10150092EL16XC1S036-230B TXV 35,600 16 13 CX35-50/60C EL296UH110XV60C 10150093EL16XC1S036-230B TXV 35,600 16 13 CX35-50/60C SL280UH090V60C 10150094EL16XC1S036-230B TXV 35,600 16 13 CX35-50/60C SL280UH090XV60C 10150095EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C SL280UH110V60C 10150096EL16XC1S036-230B TXV 35,400 16 13 CX35-50/60C SL280UH110XV60C 10150097EL16XC1S036-230B TXV 35,200 16 13 CX35-50/60C SLP98UH090XV36C 10150098EL16XC1S036-230B TXV 35,000 16 13 CX35-50/60C SLP98UH090XV48C 10150099EL16XC1S036-230B TXV 35,600 16 13 CX35-50/60C SLP98UH110XV60C 10150100EL16XC1S036-230B TXV 34,600 14.5 12.2 CX35-50/60C 10150082NOTES: TXV = Matched with Thermostatic Expansion Valve. RFC = Matched with RFC metering device.

AHRI certified to AHRI Standard 210/240 (with 25 ft. of connecting refrigerant lines); 95°F outdoor air temperature, 80°F db / 67°F wb entering evaporator air. All ratings include the use of a blower time delay relay (TDR). All Lennox variable-speed furnaces and Air Handlers have time delay capabilities. Other Furnaces and Air Handlers may require an optional time delay relay (58M81) for field installation. See furnace or air handler specifications to determine if relay is needed.Also see Expansion Valve Kit Usage Table.

NOTE - Due to Lennox’ ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. ©2017 Lennox Industries, Inc.

Visit us at www.lennox.com

For the latest technical information, www.LennoxPROs.com

Contact us at 1-800-4-LENNOX

REVISIONS

REVISIONS

Sections Description of Change

AHRI System Matches Updated