  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    1/61

    HUAWEI TECHNOLOGIES CO., LTD.

    All rights reserved

    www.huawei.com

    Internal

    OptiX SDH/OSN Series

    Equipment General

    Configuration

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    2/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 2All rights reserved

    References

    OptiX T2000 Operator Guide for SDH

    OptiX iManager T2000 Administrator

    Guide for SDH

    OSN3500&2500&1500 Configuration

    Guide

    OSN7500 Configuration Guide

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    3/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 3All rights reserved

    Upon completion of this course, you will be able to:

    Understand the menus of OptiX iManager T2000

    Create Topology including create NE/Link

    Perform the NE configuration, board configuration,

    service dispatching and protection configuration for

    equipment via OptiX iManager T2000

    Perform the Security Management, including Create NE

    User, managing NE/T2000 login

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    4/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 4All rights reserved

    Chapter 1 Creating TopologiesCha

    pter 1 Creating Topologies

    Chapter 2 Configuring ProtectionChapter 2 Configuring Protection

    Chapter 3 Configuring ServicesChapter 3 Configuring Services

    Chapter 4Chapter 4Configuring ClockConfiguring Clock

    Chapter 5 Configuring Overhead InterfaceChapter 5 Configuring Overhead Interface

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    5/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 5All rights reserved

    Chapter 6 Configuring Alarm and PerformanceChapter 6 Configuring Alarm and PerformanceMonitoringMonitoring

    Chapter 7 Synchronization and Data ManagementChapter 7 Synchronization and Data Management

    Chapter 8 NE Security ManagementChapter 8 NE Security Management

    Chapter 9 Configuring CommunicationChapter 9 Configuring Communication

    Chapter 10 Configuring Board ParametersChapter 10 Configuring Board Parameters

    Chapter 11 ReportsChapter 11 Reports

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    6/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 6All rights reserved

    Creating Topologies

    Recommended Creation Sequence

    Step Description

    1 Creating GNEs & NEs

    2 Creating a Sub-racks and Boards

    3 Creating Links

    4 Creating a Topology Subnet

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    7/61HUAWEI TECHNOLOGIES CO., LTD. Page 7All rights reserved

    Creating Topologies

    Creating Optical NEs in batch

    Select [File/Search for NE] from the Main

    Menu.

    Click . The NEs found are

    displayed after the search.

    Click , and click in the

    confirmation box.

    Click .

    Enter the NE user name and password.

    Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    8/61HUAWEI TECHNOLOGIES CO., LTD. Page 8All rights reserved

    Creating Topologies

    Creating Optical NEs Manually

    Creating Gateway Network Element (GNE)

    1. Click File/Create/Topology Object.

    2. Choose the NE type to be created.

    3. Complete the following information: ID,

    extended ID, name and remarks.

    4. Select "Gateway" from the "Gateway Type"

    drop-down list and "IP" from the "Protocol"

    drop-down list. Enter the IP address andport number of the GNE.

    5. Enter the NE user and password.

    6. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    9/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 9All rights reserved

    Creating Topologies

    Creating Optical NEs Manually

    Creating Non-Gateway Network Element

    1. Click File/Create/Topology Object.

    2. Choose the NE type to be created.

    3. Complete the following information: ID,

    extended ID, name and remarks.

    4. Select "Non-Gateway" from the "Gateway

    Type" drop-down list. Select the GNE the

    NE is affiliated to from the "AffiliatedGateway" drop-down list.

    5. Enter the NE user and password.

    6. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    10/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 10All rights reserved

    Creating Topologies

    Creating Sub-racks and Boards (1/2)

    Double-click unconfigured NE icon on the Main Topology.

    Select "Manual Configuration" and click .

    Click in the two "Confirm" dialogue box.

    Set the NE attributes and click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    11/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 11All rights reserved

    Creating Topologies

    Creating Sub-racks and Boards (2/2)

    The NE Panel is displayed.

    1. Right-click the slot and select the board type or Click

    to upload the data to the

    physical slot from the NE.

    2. After all the boards have been created, click .

    3. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    12/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 12All rights reserved

    Creating Topologies

    Searching fibers

    Select [File/Search for Fiber/Cable].

    Click .

    After finding the fibers, Click . Click .

    Creating fibers manually

    Select the shortcut icon on the

    toolbar of the Main Topology and

    the cursor changes to a "+".

    Click the source NE of the fiber or

    cable on the Main Topology.

    Select the source board and port.

    Click and the cursor

    changes to a "+".

    Click the sink NE of the fibre or

    cable on the Main Topology.

    Select the sink board and port

    Click twice.

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    13/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 13All rights reserved

    Creating Topologies

    Creating a Topology Subnet

    1. Select [File/Create/Subnet].

    2. Select the "Basic Attributes" tab. Enter the

    information of the subnet.3. Select the "Object Selection" tab. Select

    the created NEs or subnet from the "Object

    Not Selected" pane, and add them to the

    "Selected Object" pane by clicking the

    double-right-arrow button.

    4. Click .5. Click in the Main Topology.

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    14/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 14All rights reserved

    Chapter 1 Creating TopologiesChapter 1 Creating Topologies

    Chapter 2 Configuring ProtectionChapter 2 Configuring Protection

    Chapter 3 Configuring ServicesChapter 3 Configuring Services

    Chapter 4Chapter 4 Configuring ClockConfiguring Clock

    Chapter 5Chapter 5 Configuring Overhead InterfaceConfiguring Overhead Interface

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    15/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 15All rights reserved

    Configuring Board-level ProtectionConfiguring TPS Protection

    Configuring MSP Ring Configuring SNCP

    Network level protection

    Equipment level protection

    Configuring Protection

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    16/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 16All rights reserved

    Configuring Protection

    Configuring TPS Protection

    In the NE Explorer, click the NE and select [Configuration/TPS

    Protection] from the Function Tree.

    Click to enter the dialog box .

    Select a protection board and working boards. Set switching priorities

    for the working boards.

    Set the "WTR Time.

    Click .

    Equipment Level Protection

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    17/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 17All rights reserved

    Configuring Protection

    Creating Board-level Protection

    In the NE Explorer, click the NE and select [Configuration/Board-Level

    Protection] from the Function Tree.

    Click .

    Select Primary Board and Standby Board, and set Protection Group ID.

    Click .

    Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    18/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 18All rights reserved

    Configuring Protection

    Creating a Two-Fiber MS-SPRing

    Select [Configuration/Protection View]

    Select [Protection View/Create SDH Protection Subnet/2f_MS SPRing].

    Select the rate of the protection subnet.

    Double-click on the nodes to be in the protection subnet.

    Click .

    Click to send the configurations.

    Network Level Protection

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    19/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 19All rights reserved

    Configuring Protection

    Configuring SNCP Protection

    Select [Configuration/Protection View] from the Main Menu.

    Right-click the NE to be created as the SNCP node, and select[Create SNCP Node/Create xxx SNCP Node] ("xxx" refers to thename of the protection subnet of this NE)

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    20/61

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    21/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 21All rights reserved

    Using the Trail Management

    Function

    Using the Single Station

    Function

    ConfiguringSDH/PDH service

    ConfiguringEthernet service

    ConfiguringATM service

    Service type

    Configuration Method

    Configuring Service

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    22/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 22All rights reserved

    Method 1 -- Using the Trail Management Function

    Configure SDH/PDH service

    It is recommended to configure SDH services by the

    process below

    Stage Description Remark

    1 Creating an SDH trail

    According to trail level: Creating a VC4 Server Trail

    Creating a VC4/VC4-Xc Trail

    Creating a VC12/VC3 Trail

    2 Changing Trail Type Optional

    3 Viewing Trail

    4Configuring the Maintenance

    Parameters of a Created Trail

    5 Deleting a Trail Optional

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    23/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 23All rights reserved

    Method 1 -- Using the Trail Management Function

    Creating a VC4 Server Trail Select [Trail/SDH Trail Creation] from the Main Menu.

    Set the service direction to "Bidirectional" and level to "VC4 Server Trail".

    Double-click the source NE and then the sink NE. The trail selected

    automatically will be displayed between the NEs.

    Set a name and ID for the route.

    To send the configurations to the NE, select the "Activate" checkbox.

    (optional)

    Select the "Copy after Creation" checkbox if you want to create multiple

    trails with the same route. (optional)

    Click . The "Operation Result" dialogue box is displayed and

    indicates operation succeeded. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    24/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 24All rights reserved

    Method 1 -- Using the Trail Management Function

    Creating a VC4 Server Trail

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    25/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 25All rights reserved

    Method 1 -- Using the Trail Management Function

    Creating a VC-12/VC3 Trail Select [Trail/SDH Trail Creation] from the Main Menu.

    Select the service direction and set the service level to "VC12" or "VC3".

    Double-click the source NE and then the sink NE. Select the port in the "CreateTrail-Select Board Port" dialogue box and click .

    Click the "Trail setting" tab. Set a name and ID for the route.

    To send the configurations to the NE, select the "Activate" checkbox.

    Select the "Copy after Creation" checkbox if you want to create multiple trailswith the same route. (optional)

    Click . The "Operation Result" dialogue box is displayed and indicates

    operation succeeded. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    26/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 26All rights reserved

    Method 1 -- Using the Trail Management Function

    Creating a VC-12/VC3 Trail

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    27/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 27All rights reserved

    Method 2 -- Using the Single Station Function

    Configure SDH/PDH service

    In the NE Explorer, click the NE

    and select [Configuration/SDH

    Service Configuration] from the

    Function Tree.

    Click .

    Complete the information as

    required.

    Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    28/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 28All rights reserved

    Chapter 1 Creating TopologiesChapter 1 Creating Topologies

    Chapter 2 Configuring ProtectionChapter 2 Configuring Protection

    Chapter 3 Configuring ServicesChapter 3 Configuring Services

    Chapter 4 Configuring ClockChapter 4 Configuring Clock

    Chapter 5Chapter 5 Configuring Overhead InterfaceConfiguring Overhead Interface

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    29/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 29All rights reserved

    Configuring Clock

    Setting the System Clock Source Priority List

    Setting Switching Conditions for a Clock Source

    Setting Restoration Parameters for a Clock Source

    Setting an External Clock Source Setting the Clock Subnet

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    30/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 30All rights reserved

    Configuring Clock

    Setting the Priority Table for a Reference Clock

    Select [Configuration/Clock View] from the Main Menu.

    Right-click the NE icon in the Clock View and select [Clock Source PriorityList].

    Click , and the "Add Clock Source" dialogue box is displayed.

    Select a reference clock source and click . Click . The "Operation Result" dialogue box is displayed and indicates

    operation succeeded. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    31/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 31All rights reserved

    Configuring Clock

    Setting Switching Conditions for a Clock Source

    In the NE Explorer, click the NE and select [Configuration/Clock/Clock

    Source Switching] from the Function Tree.

    Select the "Clock Source Switching Condition" tab. Click .

    Double-click the parameters to set clock switching conditions.

    Click . The "Operation Result" dialogue box is displayed and

    indicates operation succeeded. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    32/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 32All rights reserved

    Configuring Clock

    Setting Restoration Parameters for a Clock Source In the NE Explorer, click the NE and select

    [Configuration/Clock/Clock Source Switching] from the FunctionTree.

    Select the "Clock Source Reversion Parameter" tab. Click.

    Double-click the parameters to set restoration parameters.

    Click . The "Operation Result" dialogue box is displayedand indicates operation succeeded. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    33/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 33All rights reserved

    Configuring Clock

    Setting an External Clock Source

    Right-click the NE icon in the Clock View and select [Clock Source

    Priority List].

    Set "External Clock Source Mode" and "Synchronous Status Byte"

    for the external clock source.

    Click . The "Operation Result" dialogue box is displayed

    and indicates operation succeeded. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    34/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 34All rights reserved

    Configuring Clock Setting the Clock Subnet ---- Setting a Clock Subnet Attributes

    Right-click the NE icon in the Clock View and select [Clock Subnet Settings].

    On the "Clock Subnet" tab, set the clock subnet parameters.

    Click . The "Operation Result" dialogue box is displayed and indicates operation

    succeeded. Click .

    Select the "Clock ID Status" tab. If a clock ID is assigned to the line clock source, set

    "Clock ID Status" to "Enabled".

    Click . The "Operation Result" dialogue box is displayed and indicates operation

    succeeded. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    35/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 35All rights reserved

    Configuring Clock Setting the Clock Subnet --- - Setting Clock Source Quality

    Right-click the NE icon in the Clock View and select [Clock Subnet Setting]. Click the

    "Clock Quality" tab.

    Set "Configuration Quality".

    Click . The "Operation Result" dialogue box is displayed and indicates operation

    succeeded. Click .

    Select the "Manual Setting of 0 Quality Level" tab. Set the quality for the unknown clock

    source.

    Click . The "Operation Result" dialogue box is displayed and indicates operation

    succeeded. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    36/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 36All rights reserved

    Configuring Clock

    Setting the Clock Subnet ---- Setting SSM Output

    Right-click the NE icon in the Clock View and select [Clock Subnet

    Setting]. Click the "SSM Output Control" tab.

    Set "Control Status" of the clock source.

    Click . The "Operation Result" dialogue box is displayed

    and indicates operation succeeded. Click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    37/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 37All rights reserved

    Chapter 1 Creating TopologiesChapter 1 Creating Topologies

    Chapter 2 Configuring ProtectionChapter 2 Configuring Protection

    Chapter 3 Configuring ServicesChapter 3 Configuring Services

    Chapter 4 Configuring ClockChapter 4 Configuring Clock

    Chapter 5 Configuring Overhead InterfaceChapter 5 Configuring Overhead Interface

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    38/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 38All rights reserved

    Configuring Overhead Interface

    Configuring the Orderwire

    Phone

    In the NE Explorer, click the NE and

    select [Configuration/Orderwire] from

    the Function Tree. Select the"General" tab.

    Set "Call Waiting Time (s)", "Dialing

    Mode", "Telephone No." and the

    Orderwire ports.

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    39/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 39All rights reserved

    Chapter 6 Configuring Alarm and PerformanceChapter 6 Configuring Alarm and Performance

    MonitoringMonitoring

    Chapter 7 Synchronization and Data ManagementChapter 7 Synchronization and Data ManagementChapter 8 NE Security ManagementChapter 8 NE Security Management

    Chapter 9 Configuring CommunicationChapter 9 Configuring Communication

    Chapter 10 Configuring Board ParametersChapter 10 Configuring Board Parameters

    Chapter 11Chapter 11 ReportsReports

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    40/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 40All rights reserved

    Setting Alarm Dump Conditions

    1.Select [System Administration/Database

    Management/Dump] from the Main Topology.

    2. Select the Dumping Conditions tab. In the

    left-hand Record Type list, select Alarm

    Event .

    3. In the right-hand pane, under Dumping

    when Overflow, set a value for Max. Storage

    Capacity, Number of Dumped Records and

    Capacity Alarm Threshold respectively.

    4. Under Dumping in Schedule, set "Dump

    Periodically or not" to "Yes".Set "Dump

    Interval" and "Time Limit" , then click

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    41/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 41All rights reserved

    Setting Performance Monitoring Start/Stop Status

    1.Select [Configuration/NE Time Synchronization] from the Main Topology

    2. Select NEs from the object tree and then right click to select [Synchronize with NMTime]. Click in the pop-up confirmation box.

    3.A dialog box is displayed to prompt that synchronization succeeded. Click

    4.Select [Performance/NE Performance Monitor Time] from the Main Topology

    6.Perform the following settings , then Click

    Set 15-minute Monitoring: Open

    Set 24-hour Monitoring: Open

    Start time: set as required and must be later than the current time of the NM and NE.

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    42/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 42All rights reserved

    Chapter 6 Configuring Alarm and PerformanceChapter 6 Configuring Alarm and Performance

    MonitoringMonitoring

    Chapter 7 Synchronization and Data ManagementChapter 7 Synchronization and Data ManagementChapter 8 NE Security ManagementChapter 8 NE Security Management

    Chapter 9 Configuring CommunicationChapter 9 Configuring Communication

    Chapter 10 Configuring Board ParametersChapter 10 Configuring Board Parameters

    Chapter 11Chapter 11 ReportsReports

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    43/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 43All rights reserved

    Synchronization and Data Management

    Synchronizing NE Time

    Synchronizing Current NE Alarms

    Managing NE Configuration Data

    Backing Up/Restoring the NE Database Using FTP

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    44/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 44All rights reserved

    Synchronizing NE Time with the NM Server Manual Synchronization

    1.Select [Configuration/NE Time Synchronization] from the Main Menu

    In the left pane, select one or more NEs

    2.Modify the value of Synchronize Mode to NM then click --

    3.Select one or more NE entries. Right-click and select [Synchronize withNM Time].

    Automatic Synchronization 1.Select [Configuration/NE Time Synchronization] from the Main Menu.

    2.In the left pane, select one or more NEs

    3.Set Synchronize Starting Time and Synchronization Period.

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    45/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 45All rights reserved

    Synchronizing Current NE Alarms

    Synchronizing Networkwide Alarms

    Select [Fault/Synchronize Networkwide

    Alarms] from the Main Menu. A progress bar is

    displayed.

    Synchronizing NE Alarms

    Select an NE in the Main Topology

    Right-click the selected object and select

    [Synchronize Current Alarm]. A progress bar is

    displayed.

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    46/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 46All rights reserved

    Backing Up NE Configuration Data

    1.Select [Configuration/Configuration Data Management] from the Main Menu

    2.In the left pane, select the desired NEs

    3.Select one or more NEs in the Configuration Data Management List.

    4.Click . This is also available in the shortcut menu

    5.A dialog box is displayed to prompt that backup succeeded. Click

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    47/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 47All rights reserved

    Backing Up NM Configuration Data1.Select [File/Logout] from the Main Topology. Click in the subsequent prompt.

    2.Enter the following in the login interface

    3.Select [System Administration/Single User Mode] from the Main Topology. Click in the subsequent prompt.

    4. To backup immediately :Select [System Administration//DatabaseManagement/Backup] from the Main Topology. Select immediate backup, and thesystem backs up the NM database to the appointed directory immediately

    5.To backup periodically, perform the following settings

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    48/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 48All rights reserved

    Chapter 6 Configuring Alarm and PerformanceChapter 6 Configuring Alarm and Performance

    MonitoringMonitoring

    Chapter 7 Synchronization and Data ManagementChapter 7 Synchronization and Data ManagementChapter 8 NE Security ManagementChapter 8 NE Security Management

    Chapter 9 Configuring CommunicationChapter 9 Configuring Communication

    Chapter 10 Configuring Board ParametersChapter 10 Configuring Board Parameters

    Chapter 11Chapter 11 ReportsReports

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    49/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 49All rights reserved

    Creating an NE User1.Select [System Administration/NE Security Management/NE User Management]

    from the menu2.Select NE from the object tree. Select NE and click .

    3.Enter the name, user level, user flag, password, and detailed description of thenew NE user: e.g. create a unified NE user t2000 for NE1NE5, as shown in thediagram below. The length of the password of the NE user ranges from 6 to16characters, including at least one letter and one numeral. And the length of the NE

    User ranges from 2 to 8 characters

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    50/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 50All rights reserved

    Chapter 6 Configuring Alarm and PerformanceChapter 6 Configuring Alarm and Performance

    MonitoringMonitoring

    Chapter 7 Synchronization and Data ManagementChapter 7 Synchronization and Data ManagementChapter 8 NE Security ManagementChapter 8 NE Security Management

    Chapter 9 Configuring CommunicationChapter 9 Configuring Communication

    Chapter 10 Configuring Board ParametersChapter 10 Configuring Board Parameters

    Chapter 11Chapter 11 ReportsReports

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    51/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 51All rights reserved

    Configuring communication Setting NE Communication

    Parameters

    1. In the NE Explorer, click the

    NE and select

    [Communication/Set

    Communication Parameters]from the Function Tree

    2. Click to update

    the communication

    parameters

    3. Modify the IP, Extended ID,

    Gateway IP, Subnet Mask or

    NSAP Address as you need,

    and click .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    52/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 52All rights reserved

    Configuring communication

    Changing an Ordinary NE into a GNE 1. Select [System Administration/DCN Management] from the Main Menu

    2. Select the NE tab.

    3. Right-click an ordinary NE and select [Change to GNE]. The Change toGNE dialog box is displayed;

    4. Set the GNE type, IP Address and Port No. as you need

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    53/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 53All rights reserved

    Configuring communication Adding Standby GNEs for an NE

    1. Select [System Administration/DCN Management] from the

    Main Menu

    2. Select the NE tab

    3. Select an NE entry, add standby GNEs

    4. Click

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    54/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 54All rights reserved

    Chapter 6 Configuring Alarm and PerformanceChapter 6 Configuring Alarm and Performance

    MonitoringMonitoring

    Chapter 7 Synchronization and Data ManagementChapter 7 Synchronization and Data ManagementChapter 8 NE Security ManagementChapter 8 NE Security Management

    Chapter 9 Configuring CommunicationChapter 9 Configuring Communication

    Chapter 10 Configuring Board ParametersChapter 10 Configuring Board Parameters

    Chapter 11Chapter 11 ReportsReports

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    55/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 55All rights reserved

    Configuring Board Parameters

    Configuring SDH Boards

    Configuring PDH Boards

    Configuring Ethernet Boards

    Configuring Optical Amplifier Boards

    .

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    56/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 56All rights reserved

    Configuring the Optical Transponder Unit

    1, In the NE Explorer, select an SDH board and select

    [Configuration/SDH Interface] from the Function Tree ;

    2, Click the double-right-arrow button (red). Select "By Function" ;

    3, Select the parameter in the drop-down list ;

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    57/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 57All rights reserved

    Chapter 6 Configuring Alarm and PerformanceChapter 6 Configuring Alarm and Performance

    MonitoringMonitoring

    Chapter 7 Synchronization and Data ManagementChapter 7 Synchronization and Data ManagementChapter 8 NE Security ManagementChapter 8 NE Security Management

    Chapter 9 Configuring CommunicationChapter 9 Configuring Communication

    Chapter 10 Configuring Board ParametersChapter 10 Configuring Board Parameters

    Chapter 11 ReportsChapter 11 Reports

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    58/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 58All rights reserved

    Reports

    The Network Diagram

    The Network wide Data Report

    The NE Information Report

    The Physical Location Information Report

    The Slot Configuration Report

    The Board Information Report

    The Slot Information Report

    The Board Details Report

    The Fiber/Cable Connection

    Report

    ..

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    59/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 59All rights reserved

    Reports

    The Network wide Data Report

    1, Select [Report/Network wide

    Data Report] from the Main Menu;

    2, Click or .

    The Board Information Report

    1. Select [Report/Board Information Report]

    from the Main Menu ;

    2. Select NEs from the left pane and click

    the double-right-arrow button (red)

    3. Select the "View Board Information" tab.

    Click or

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    60/61

    HUAWEI TECHNOLOGIES CO., LTD. Page 60All rights reserved

    How to configure the SDH service?

    answer

    How to configure the clock? answer

    How to backup the NE data

    configuration? answer

    Summary

  • 7/30/2019 16-OTA105201 OptiX OSN series General configuration ISSUE1.00.ppt

    61/61

    www.huawei.com

    Thank You