day4a - ota105203 optix osn series general configuration issue1.00

61
HUAWEI TECHNOLOGIES CO., LTD. All rights reserved www.huawei.com Internal OTA105203 OptiX SDH/OSN Series Equipment General Configuration ISSUE 1.00

Upload: dung-phan-van

Post on 17-Dec-2015

242 views

Category:

Documents


7 download

DESCRIPTION

OSN3500 Configuration

TRANSCRIPT

OTA105203 OptiX OSN series General configuration ISSUE1.01ISSUE 1.00
OptiX iManager T2000 Administrator Guide for SDH
OSN3500&2500&1500 Configuration Guide
OSN7500 Configuration Guide
Upon completion of this course, you will be able to:
Understand the menus of OptiX iManager T2000
Create Topology including create NE/Link
Perform the NE configuration, board configuration, service dispatching and protection configuration for equipment via OptiX iManager T2000
Perform the Security Management, including Create NE User, managing NE/T2000 login
HUAWEI TECHNOLOGIES CO., LTD.
HUAWEI TECHNOLOGIES CO., LTD.
Monitoring
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 11 Reports
3
Select [File/Search for NE] from the Main Menu.
Click <Start Search>. The NEs found are displayed after the search.
Click <Stop Search>, and click <Yes> in the confirmation box.
Click <Create NE>.
Click <OK>.
Default NE user of the T2000: root; default password: password. The NE user to create an NE is at the system maintainer level at least.
You can check the “NE Pre-Configuration” check box if the data has been created at the NE side.
Notes: if there are special required, we also can create OSI GNE. The detail please refer to the <Operation Manual for SDH>
HUAWEI TECHNOLOGIES CO., LTD.
Click File/Create/Topology Object.
Complete the following information: ID, extended ID, name and remarks.
Select "Gateway" from the "Gateway Type" drop-down list and "IP" from the "Protocol" drop-down list. Enter the IP address and port number of the GNE.
Enter the NE user and password.
Click <OK>.
Default NE user of the T2000: root; default password: password. The NE user to create an NE is at the system maintainer level at least.
You can check the “NE Pre-Configuration” check box if the data has been created at the NE side.
Notes: if there are special required, we also can create OSI GNE. The detail please refer to the <Operation Manual for SDH>
HUAWEI TECHNOLOGIES CO., LTD.
Complete the following information: ID, extended ID, name and remarks.
Select "Non-Gateway" from the "Gateway Type" drop-down list. Select the GNE the NE is affiliated to from the "Affiliated Gateway" drop-down list.
Enter the NE user and password.
Click <OK>.
Default NE user of the T2000: root; default password: password. The NE user to create an NE is at the system maintainer level at least.
You can check the “NE Pre-Configuration” check box if the data has been created at the NE side.
Notes: if there are special required, we also can create OSI GNE. The detail please refer to the <Operation Manual for SDH>
HUAWEI TECHNOLOGIES CO., LTD.
Double-click unconfigured NE icon on the Main Topology.
Select "Manual Configuration" and click <Next>.
Click <OK> in the two "Confirm" dialogue box.
Set the NE attributes and click <Next>.
HUAWEI TECHNOLOGIES CO., LTD.
Creating Sub-racks and Boards (2/2)
The NE Panel is displayed.
Right-click the slot and select the board type or Click <Query Physical Slot (s)> to upload the data to the physical slot from the NE.
After all the boards have been created, click <Next>.
Click <Finish>.
Click <Create Fibre>.
Creating fibers manually
Select the shortcut icon on the toolbar of the Main Topology and the cursor changes to a "+".
Click the source NE of the fiber or cable on the Main Topology.
Select the source board and port.
Click <OK> and the cursor changes to a "+".
Click the sink NE of the fibre or cable on the Main Topology.
Select the sink board and port
Click <OK> twice.
Select [File/Create/Subnet].
Select the "Basic Attributes" tab. Enter the information of the subnet.
Select the "Object Selection" tab. Select the created NEs or subnet from the "Object Not Selected" pane, and add them to the "Selected Object" pane by clicking the double-right-arrow button.
Click <OK>.
HUAWEI TECHNOLOGIES CO., LTD.
HUAWEI TECHNOLOGIES CO., LTD.
Configuring TPS Protection
In the NE Explorer, click the NE and select [Configuration/TPS Protection] from the Function Tree.
Click <Create> to enter the dialog box .
Select a protection board and working boards. Set switching priorities for the working boards.
Set the "WTR Time“.
Creating Board-level Protection
In the NE Explorer, click the NE and select [Configuration/Board-Level Protection] from the Function Tree.
Click <New>.
Select Primary Board and Standby Board, and set Protection Group ID.
Click <OK>.
Click <Close>.
Double-click on the nodes to be in the protection subnet.
Click <Next>.
Network Level Protection
Select [Configuration/Protection View] from the Main Menu.
Right-click the NE to be created as the SNCP node, and select [Create SNCP Node/Create xxx SNCP Node] ("xxx" refers to the name of the protection subnet of this NE)
HUAWEI TECHNOLOGIES CO., LTD.
HUAWEI TECHNOLOGIES CO., LTD.
Configuring SDH/PDH service
Configuring Ethernet service
Configuring ATM service
Configure SDH/PDH service
It is recommended to configure SDH services by the process below
Stage
Description
Remark
1
Creating an SDH trail
According to trail level: Creating a VC4 Server Trail Creating a VC4/VC4-Xc Trail Creating a VC12/VC3 Trail
2
5
Creating a VC4 Server Trail
Select [Trail/SDH Trail Creation] from the Main Menu.
Set the service direction to "Bidirectional" and level to "VC4 Server Trail".
Double-click the source NE and then the sink NE. The trail selected automatically will be displayed between the NEs.
Set a name and ID for the route.
To send the configurations to the NE, select the "Activate" checkbox. (optional)
Select the "Copy after Creation" checkbox if you want to create multiple trails with the same route. (optional)
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.
Creating a VC4 Server Trail
HUAWEI TECHNOLOGIES CO., LTD.
Creating a VC-12/VC3 Trail
Select [Trail/SDH Trail Creation] from the Main Menu.
Select the service direction and set the service level to "VC12" or "VC3".
Double-click the source NE and then the sink NE. Select the port in the "Create Trail-Select Board Port" dialogue box and click <OK>.
Click the "Trail setting" tab. Set a name and ID for the route.
To send the configurations to the NE, select the "Activate" checkbox.
Select the "Copy after Creation" checkbox if you want to create multiple trails with the same route. (optional)
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.
Creating a VC-12/VC3 Trail
HUAWEI TECHNOLOGIES CO., LTD.
Configure SDH/PDH service
In the NE Explorer, click the NE and select [Configuration/SDH Service Configuration] from the Function Tree.
Click <Create>.
Click <OK>.
HUAWEI TECHNOLOGIES CO., LTD.
Setting an External Clock Source
Setting the Clock Subnet
HUAWEI TECHNOLOGIES CO., LTD.
Select [Configuration/Clock View] from the Main Menu.
Right-click the NE icon in the Clock View and select [Clock Source Priority List].
Click <Create>, and the "Add Clock Source" dialogue box is displayed.
Select a reference clock source and click <OK>.
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.
Setting Switching Conditions for a Clock Source
In the NE Explorer, click the NE and select [Configuration/Clock/Clock Source Switching] from the Function Tree.
Select the "Clock Source Switching Condition" tab. Click <Query>.
Double-click the parameters to set clock switching conditions.
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.
Setting Restoration Parameters for a Clock Source
In the NE Explorer, click the NE and select [Configuration/Clock/Clock Source Switching] from the Function Tree.
Select the "Clock Source Reversion Parameter" tab. Click <Query>.
Double-click the parameters to set restoration parameters.
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.
Setting an External Clock Source
Right-click the NE icon in the Clock View and select [Clock Source Priority List].
Set "External Clock Source Mode" and "Synchronous Status Byte" for the external clock source.
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.
Setting the Clock Subnet ---- Setting a Clock Subnet Attributes
Right-click the NE icon in the Clock View and select [Clock Subnet Settings].
On the "Clock Subnet" tab, set the clock subnet parameters.
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
Select the "Clock ID Status" tab. If a clock ID is assigned to the line clock source, set "Clock ID Status" to "Enabled".
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.
Setting the Clock Subnet --- - Setting Clock Source Quality
Right-click the NE icon in the Clock View and select [Clock Subnet Setting]. Click the "Clock Quality" tab.
Set "Configuration Quality".
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
Select the "Manual Setting of 0 Quality Level" tab. Set the quality for the unknown clock source.
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.
Setting the Clock Subnet ---- Setting SSM Output
Right-click the NE icon in the Clock View and select [Clock Subnet Setting]. Click the "SSM Output Control" tab.
Set "Control Status" of the clock source.
Click <Apply>. The "Operation Result" dialogue box is displayed and indicates operation succeeded. Click <Close>.
HUAWEI TECHNOLOGIES CO., LTD.
HUAWEI TECHNOLOGIES CO., LTD.
Configuring the Orderwire Phone
In the NE Explorer, click the NE and select [Configuration/Orderwire] from the Function Tree. Select the "General" tab.
Set "Call Waiting Time (s)", "Dialing Mode", "Telephone No." and the Orderwire ports.
HUAWEI TECHNOLOGIES CO., LTD.
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 11 Reports
1.Select [System Administration/Database Management/Dump] from the Main Topology.
2. Select the “Dumping Conditions” tab. In the left-hand “Record Type” list, select “Alarm Event” .
3. In the right-hand pane, under “Dumping when Overflow”, set a value for “Max. Storage Capacity”, “Number of Dumped Records” and “Capacity Alarm Threshold” respectively.
4. Under “Dumping in Schedule”, set "Dump Periodically or not" to "Yes".Set "Dump Interval" and "Time Limit" , then click <OK>
HUAWEI TECHNOLOGIES CO., LTD.
1.Select [Configuration/NE Time Synchronization] from the Main Topology
2. Select NEs from the object tree and then right click to select [Synchronize with NM Time]. Click <Yes> in the pop-up confirmation box.
3.A dialog box is displayed to prompt that synchronization succeeded. Click <OK>
4.Select [Performance/NE Performance Monitor Time] from the Main Topology
6.Perform the following settings , then Click <Apply>
Set 15-minute Monitoring: Open
Set 24-hour Monitoring: Open
Start time: set as required and must be later than the current time of the NM and NE.
HUAWEI TECHNOLOGIES CO., LTD.
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 11 Reports
HUAWEI TECHNOLOGIES CO., LTD.
Manual Synchronization
In the left pane, select one or more NEs
2.Modify the value of “Synchronize Mode” to “NM” then click <apply>--<close>
3.Select one or more NE entries. Right-click and select [Synchronize with NM Time].
Automatic Synchronization
2.In the left pane, select one or more NEs
3.Set “Synchronize Starting Time” and “Synchronization Period”.
HUAWEI TECHNOLOGIES CO., LTD.
Synchronizing Networkwide Alarms
Select [Fault/Synchronize Networkwide Alarms] from the Main Menu. A progress bar is displayed.
Synchronizing NE Alarms
Select an NE in the Main Topology
Right-click the selected object and select [Synchronize Current Alarm]. A progress bar is displayed.
HUAWEI TECHNOLOGIES CO., LTD.
1.Select [Configuration/Configuration Data Management] from the Main Menu
2.In the left pane, select the desired NEs
3.Select one or more NEs in the “Configuration Data Management List”.
4.Click <Backup NE Database>. This is also available in the shortcut menu
5.A dialog box is displayed to prompt that backup succeeded. Click <Close>
HUAWEI TECHNOLOGIES CO., LTD.
Backing Up NM Configuration Data
1.Select [File/Logout] from the Main Topology. Click <OK> in the subsequent prompt.
2.Enter the following in the login interface
3.Select [System Administration/Single User Mode] from the Main Topology. Click <OK> in the subsequent prompt.
4. To backup immediately :Select [System Administration//Database Management/Backup] from the Main Topology. Select immediate backup, and the system backs up the NM database to the appointed directory immediately
5.To backup periodically, perform the following settings
HUAWEI TECHNOLOGIES CO., LTD.
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 11 Reports
1.Select [System Administration/NE Security Management/NE User Management] from the menu
2.Select NE from the object tree. Select NE and click <Add>.
3.Enter the name, user level, user flag, password, and detailed description of the new NE user: e.g. create a unified NE user “t2000” for NE1–NE5, as shown in the diagram below. The length of the password of the NE user ranges from 6 to16 characters, including at least one letter and one numeral. And the length of the “NE User” ranges from 2 to 8 characters
HUAWEI TECHNOLOGIES CO., LTD.
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 11 Reports
Setting NE Communication Parameters
1. In the NE Explorer, click the NE and select [Communication/Set Communication Parameters] from the Function Tree
2. Click <Refresh> to update the communication parameters
3. Modify the IP, Extended ID, Gateway IP, Subnet Mask or NSAP Address as you need, and click <Apply>.
HUAWEI TECHNOLOGIES CO., LTD.
1. Select [System Administration/DCN Management] from the Main Menu
2. Select the “NE” tab.
3. Right-click an ordinary NE and select [Change to GNE]. The “Change to GNE” dialog box is displayed;
4. Set the “GNE type”, “IP Address” and “Port No.” as you need
HUAWEI TECHNOLOGIES CO., LTD.
1. Select [System Administration/DCN Management] from the Main Menu
2. Select the “NE” tab
3. Select an NE entry, add standby GNEs
4. Click <Apply>
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 11 Reports
Configuring the Optical Transponder Unit
1, In the NE Explorer, select an SDH board and select [Configuration/SDH Interface] from the Function Tree ;
2, Click the double-right-arrow button (red). Select "By Function" ;
3, Select the parameter in the drop-down list ;
HUAWEI TECHNOLOGIES CO., LTD.
Chapter 7 Synchronization and Data Management
Chapter 8 NE Security Management
Chapter 9 Configuring Communication
Chapter 11 Reports
The NE Information Report
The Slot Configuration Report
The Board Information Report
The Slot Information Report
The Board Details Report
1, Select [Report/Network wide Data Report] from the Main Menu;
2, Click <Print> or <Save As>.
The Board Information Report
1. Select [Report/Board Information Report] from the Main Menu ;
2. Select NEs from the left pane and click the double-right-arrow button (red)
3. Select the "View Board Information" tab. Click <Print> or <Save As>
HUAWEI TECHNOLOGIES CO., LTD.
How to configure the clock? answer
How to backup the NE data configuration? answer
Summary
www.huawei.com