160h-1 · 2014. 2. 17. · 160h-1 16 mpa double-acting type hydraulic cylinder 16 mpa double-acting...

40
160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications Specifications of general purpose and cutting fluid proof types Nominal pressure Pressure given for a cylinder for conve- nience of naming. It is not always the same as the operating pressure (rated pressure) that guarantees performance under the specified conditions. Maximum allowable pressure The maximum allowable pressure generated in a cylinder (surge pressure, etc.) Proof test pressure Test pressure against which a cylinder can withstand without unreliability performance at the return to nominal pressure. Minimum working pressure The minimum pressure that the cylinder placed horizontally without a load can work. The hydraulic pressure generated in a cylinder due to the inertia of load must be lower than the maximum allowable pressure. In case that the lock nut is attached to the piston rod end thread part, lengthen the thread length (dimension A). Note 1) Cylinder with a bore of 140 mm and double rod type cylinder are not specified in JIS nor ISO standards. Rod series B and port Rc are in- cluded in JIS B8367-2 (not included in ISO6020-2). Note 2) Floating cushion is not provided for the rod side of the rod A. Note 3) The minimum working speed range of the combined seal type cylinder (packing code: 8) is 1 mm/s. Note 4) The standard type cylinder can be used up to the operating tempera- ture range shown in the selection materials by using packing mate- rial (6), hydrogenated nitrile rubber. Note 5) The piping spacer and gasket are attached to the G thread of 32mm bore. Note 6) Conex, material of the boots, is the trademark of Teijin, Ltd. Terminologies Petroleum-based fluid (When using other fluids, refer to the table showing applicability of fluids.) 16 MPa 20 MPa 24 MPa Metal fitting system JIS6g/6H Rc (JIS B 0203) G (ISO 1179-1) Note 5) 100 mm or less 101-250 mm 251-630 mm 631-1000 mm 1001-1600 mm 1601-2000 mm +1.4 0 +0.8 0 +1.6 0 +1.0 0 +1.8 0 +1.25 0 SD LA EA EB FA FE FB CA CB TA TC Designed to ISO 6020-2/JIS B8367-2 cylinder. Compact design and lightweight (Compared to previ- ous JIS standard.) New floating cushion provides effective cushioning and quick start of each stroke. Switches can be used to all bore sizes in standard, 32 mm to 160 mm. Seals in sliding sections were designed to ISO standard. Light weight and compact. (Comparison to 140H-8 se- ries) Rod side: Rod A 0.6 MPa or less Head side: 0.3 MPa or less Rod B 0.45 MPa or less φ32 - φ63 : 8 - 400 mm/s φ80 - φ125 : 8 - 300 mm/s φ140 φ160 : 8 - 200 mm/s Standard type : -10 - + 80°C Note 4) Switch set : -10 - + 70°C Rod end eye (T-end) Rod end clevis (Y-end) with pin Lock nut Boots : Nylon tarpaulin (Standard) : Chloroprene (Semi-standard) : Conex (Semi-standard) Note 6) Mounting styles SD, FA, FE, and FB are not specified in JIS nor ISO standards. 25 Types Temperature range (Ambient temperature and oil temperature) Nominal pressure Maximum allowable pressure Minimum working pressure Adaptable working oil Proof test pressure Structure of cushioning Tolerance of thread Tolerance of stroke Mounting type Accessories Operating speed range Note 3) Port thread

Upload: others

Post on 24-Feb-2021

4 views

Category:

Documents


1 download

TRANSCRIPT

Page 1: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder

16 MPa double-acting hydrauliccylinder with size conforming toJIS standards

Standard specifications

Specifications of general purposeand cutting fluid proof types

Nominal pressurePressure given for a cylinder for conve-nience of naming. It is not always the sameas the operating pressure (rated pressure)that guarantees performance under thespecified conditions.

Maximum allowable pressureThe maximum allowable pressure generatedin a cylinder (surge pressure, etc.)

Proof test pressureTest pressure against which a cylinder canwithstand without unreliability performanceat the return to nominal pressure.

Minimum working pressureThe minimum pressure that the cylinderplaced horizontally without a load can work.

● The hydraulic pressure generated in acylinder due to the inertia of load must belower than the maximum allowablepressure.

● In case that the lock nut is attached to thepiston rod end thread part, lengthen thethread length (dimension A).

Note 1) Cylinder with a bore of 140 mm anddouble rod type cylinder are notspecified in JIS nor ISO standards.Rod series B and port Rc are in-cluded in JIS B8367-2 (not includedin ISO6020-2).

Note 2) Floating cushion is not provided forthe rod side of the rod A.

Note 3) The minimum working speed rangeof the combined seal type cylinder(packing code: 8) is 1 mm/s.

Note 4) The standard type cylinder can beused up to the operating tempera-ture range shown in the selectionmaterials by using packing mate-rial (6), hydrogenated nitrile rubber.

Note 5) The piping spacer and gasket areattached to the G thread of 32mmbore.

Note 6) Conex, material of the boots, is thetrademark of Teijin, Ltd.

Terminologies

Petroleum-based fluid

(When using other fluids, refer to the table showing applicability of fluids.)

16 MPa

20 MPa

24 MPa

Metal fitting system

JIS6g/6H

Rc (JIS B 0203) • G (ISO 1179-1) Note 5)

100 mm or less 101-250 mm 251-630 mm

631-1000 mm 1001-1600 mm 1601-2000 mm+1.4 0

+0.8 0

+1.6 0

+1.0 0

+1.8 0

+1.25 0

SD • LA • EA • EB • FA • FE • FB • CA • CB • TA • TC

• Designed to ISO 6020-2/JIS B8367-2 cylinder.

• Compact design and lightweight (Compared to previ-ous JIS standard.)

• New floating cushion provides effective cushioning andquick start of each stroke.

• Switches can be used to all bore sizes in standard, 32mm to 160 mm.

• Seals in sliding sections were designed to ISO standard.

• Light weight and compact. (Comparison to 140H-8 se-ries)

Rod side: Rod A 0.6 MPa or less Head side: 0.3 MPa or less

Rod B 0.45 MPa or less

φ32 - φ63 : 8 - 400 mm/sφ80 - φ125 : 8 - 300 mm/sφ140 • φ160 : 8 - 200 mm/s

Standard type : -10 - + 80°C Note 4)

Switch set : -10 - + 70°C

• Rod end eye (T-end)

• Rod end clevis (Y-end) with pin

• Lock nut

• Boots : Nylon tarpaulin (Standard): Chloroprene (Semi-standard): Conex (Semi-standard) Note 6)

• Mounting styles SD, FA, FE, and FB are not specified in JIS nor ISO standards.

25

Types

Temperature range(Ambient temperatureand oil temperature)

Nominal pressure

Maximum allowable pressure

Minimum workingpressure

Adaptable working oil

Proof test pressure

Structure of cushioning

Tolerance of thread

Tolerance of stroke

Mounting type

Accessories

Operating speed rangeNote 3)

Port thread

Page 2: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinder

Rod A

Rod B

Rod B

Rod A

Lines

Gen

eral

pu

rpo

se t

ype

S

Unit : mm

Structure Type φ40

Standard type160H-1

φ50 φ63 φ80 φ100 φ125 φ140 φ160φ32 Rod dia.

DoubleActingDouble

Rod

Double Acting Single Rod Double Acting Double Rod

Standard type (160H-1) Switch set (160H-1R) Standard type (160H-1D) Switch set (160H-1RD)

Standard stroke fabrication range Unit : mm

Bore

φ32

φ40 . φ50

φ63

φ80 - φ160

Stroke

- 1200

- 1600

- 1800

- 2000

• The strokes above indicate the maximum available strokesfor the standard type. If you request larger strokes than thosein the table above, contact us.

• For the rod buckling, check with the buckling chartin the selection materials.

L LCushion stroke length Unit : mm

• Figures shown in the table above indicate the cushion stroke lengths in the case of cylindersused up to the stroke end.

• In the case that a cylinder is not used up to the stroke end, and if it is stopped 5 mm or morebefore the stroke end, the cushioning effect will be weakened. In such a case, contact us.

Cushion ringlength L

Cushion ringparallel part

length φ32

φ40 - φ80

φ100 . φ125

φ140 . φ160

Bore

21

25

30

6

8

Rod B

Notes) • When using a switch, use a switch set cylinder.• No switch can be mounted onto the standard type cylinder.

Packing structure table

Urethane rubber

Packing code

Name of type

8

Combined seal type

Pack

ing

stru

ctur

e

Piston packing

Rod packing and

wiper ring

Fixed section (including O-ring)

Hydrogenated nitrile rubber Nitrile rubber

Hydrogenated nitrile rubber

Hydrogenated nitrile rubber

Hydrogenated nitrile rubber

1

Nitrile rubber type

2

Urethane rubber type

6

Hydrogenated nitrile rubber type

Nitrile rubber Nitrile rubber Hydrogenated nitrile rubber Nitrile rubber

Fluoric resin

Nitrile rubber

Urethane rubber

Nitrile rubber

Wearing Wearing

26

DoubleActingSingleRod

Rod BStandard type

160H-1D

Switch set160H-1R

Switch set160H-1RD

Page 3: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder

General purpose type

• Standard typePac

king m

ateria

l

Series

Cushio

n typ

e

Cylind

er bo

re

Mounti

ng ty

pe

Rod ty

pe

Stroke

Rod end

attach

ment

Lock

nut

Boots

Mounting type

Cylinder stroke (mm)

B with cushions on both ends

R with cushion on the rod side

H with cushion on the head side

N without cushion

The items in broken lines in the codes below need not to be entered, if unnecessary. Semi-standard specification

2 LA 50 B 100B – –

Cushion

valve

positio

n

Cushion valve position (A, B, C, D, 0)

B –

Switch

code

Switch q

uanti

ty

• Switch set 2 LA 50 B 100B – –B –AH 2

160H-1

160H-1R

Double-Acting Single Rod

1 Nitrile rubber

2 Urethane rubber

6 Hydrogenated nitrile rubber

8 Combined seal

Cylinder bore (mm)

Rod B

φ32 • φ40 • φ50 • φ63 • φ80 • φ100 • φ125 • φ140 • φ160

Rod A

φ40 • φ50 • φ63 • φ80 • φ100 • φ125

A Rod A

B Rod B

Switch symbolNote) Select applicable switches out of the

Switch List ! Notes on order for switch sets• If a switch is unnecessary, enter the switch

code and the switch quantity of 0.

Switch quantity (1, 2, to n)

Nylon tarpaulin

Chloroprene

Conex

JJNJK

Mounting type Codes in the < > marks below are names called in ISO 6020-2.

SD SD type (Basic type)

EB EB type (Rectangular head cover attached)

TC TC type (intermediate trunnion mounting)

LA LA type (Side lugs mounting)

CA CA type (Eye mounting)

CB CB type (Clevis mounting)

TA TA type (head trunnion mounting)

EA EA type (Rectangular rod cover attached)

• For packing configuration, refer tothe selection materials at the begin-ning of this catalogue.

K Long thread with lock nut

• For thread length, refer to the

"Rod end attachment/Threadlength with lock nut".

FA FA type (head rectangular flange mounting)

FE FE type (head rectangular flange mounting)

FB FB type (cap rectangular flange mounting)

(for Rod B)

<MS2>

<ME5>

<ME6>

<MP3>

<MP1>

<MT1>

<MT4>

Note) SD, FA, FE, and FB types are not included in ISO standards.

Port p

ositio

n

Port position (A, B, C, D)

A

A

Port sp

ecifica

tion

T T-end (rod end eye)

Y Y-end (rod end clevis)

Rc thread

G thread

None

27

160H-1 : Standard type160H-1R : Switch set

Double-Acting Double Rod

160H-1D : Standard type160H-1D : Switch set

G

11 12

1 2 3 4 6

(for Rod A)

78 9 10 11 12 13

1415

5

Page 4: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinder

Switch List

Notes) ● For the switches without a protective circuit, be sure to provide the protective circuit (SK-100) with load devices when using induction load devices(relay, etc.).

● For the handling of switches, be sure to refer to the switch specifications in the end of this catalogue.● For the 200 V AC type, contact us.● We recommend AND UNIT (AU series) for multiple switches connected in series.

Kind Switch codeLoad voltage

rangeLoad current

range

Maximum open/close

capacity

Protective circuit Indicating lamp Wiring method Cord length

Applicable load device

Con

tact

No

cont

act

AF

AG

AH

AJ

AE

AK

AL

AP

AR

AS

AT

AN

AU

AW

BE

BF

CE

CF

CH

CJ

BM

BN

CM

CN

CT

CU

CV

CW

CX

CY

AX101

AX105

AX111

AX115

AX125

AX11A

AX11B

AZ101

AZ105

AZ111

AZ115

AZ125

AZ11A

AZ11B

AX201

AX205

AX211

AX215

AX21C

AX21D

AZ201

AZ205

AZ211

AZ215

AX211CE

AX215CE

AX21BCE

AZ211CE

AZ215CE

AZ21BCE

1.5m

5m

1.5m

5m

5m

0.5m

0.5m

1.5m

5m

1.5m

5m

5m

0.5m

0.5m

1.5m

5m

1.5m

5m

0.5m

1m

1.5m

5m

1.5m

5m

1.5m

5m

0.5m

1.5m

5m

0.5m

DC:5 - 30V

AC:5 - 120V

DC:5 - 40mA

AC:5 - 20mADC:1.5W

AC:2VA

DC:1.5W

AC:2VA

DC:5 - 40mA

AC:5 - 20mA

DC:5 - 30V

AC:5 - 120V

DC:5 - 30V 5- 40mA -

AC:5 - 120V

DC:5 - 30V

5 - 20mA

5 - 40mA

DC: 30 V or lessAC: 120 V or less

DC:40mA or lessAC:20mA or less

DC:30Vor lessAC:120Vor less

DC:40mAor lessAC:20mAor less

2VA

1.5W

2VA

1.5W

5 - 20mA

5 - 40mA

AC:5 - 120V

DC:5 - 30V

None

Present

None

Present

None

Present

None

Present

Present

LED(Lights up in red

during ON)

0.3mm2, 2-core, outer dia.

4mm, rear wiring

0.3mm2, 2-core, outer dia.

4mm, upper wiring

0.3mm2, 2-core, outer dia.

4mm, rear wiring

0.3mm2, 2-core, outer dia.

4mm, upper wiring

LED(Lights up in red

during ON)4-pin connector type, rear wiring

4-pin connector type, upper wiring

4-pin connector type, rear wiring

LED(Lights up in red

during ON)

LED(Lights up in red

during ON)LED

(Lights up in red during ON)

LED(Lights up in red

during ON)

(2-lamp type, red/green)

(2-lamp type, red/green)

No

No

Small relay programmable

controller

Small relay programmable

controller

No

cont

act

(CE

cof

orm

ed)

0.3mm2, 2-core, outer dia. 4mm,

rear wiring

0.3mm2, 2-core, outer dia. 4mm,

upper wiring

4-pin connector type, rear wiring

4-pin connector type, upper wiring

LED(2-lamp type,

red/green)

Small relay programmable

controllerDC:5 - 30V 5 - 40mA Present-

AX type (Rear wiring) AZ type (Upper wiring)Cord type Connector type Cord type Connector type

28

Standard stroke fabrication range

Bore

φ32

φ40 . φ50

φ63

φ80 - φ160

Stroke

- 1200

- 1600

- 1800

- 2000

• The strokes above indicate the maximum available strokes forthe standard type. If you request larger strokes than those inthe table above, contact us.

• For the rod buckling, check with the buckling chart in the se-lection materials.

Unit : mm

1 Nitrile rubber

2 Urethane rubber

6 Hydrogenated nitrile rubber

Adaptability of working oil to packing material

Packingmaterial

Notes)1. The and K -marked items are applicable, while the ✕ -marked itemsare inapplicable. For the use of the -marked items, contact us.

2. The -marked items are the recommended packing materials in case ofgiving the first priority to abrasion resistance.

3. When using 8 combined seals, refer to the notes on nitrile rubber seals.

K

Adaptable working oil

O/WOil in water

fluid

K

W/OWater inoil fluid

Phosphateesterfluid

K

Water-glycol fluid

K

K

Petroleum-basedfluid

Page 5: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder

160H-1 2CA50BB100-AB-X PPCRod side port and cushion valve position

160H-1R 2CA50BB100 - G A B

Standard specifications● With both ends cushions● Port position A , cushion valve po-

sition B

A

B

C

D

Unit: mmSwitch mounting allowable min. strokeNotes) • For the TC type (with a switch), cylinder strokes in

case that the TC type attachment shown in the figuresbelow is positioned closest to the cover are shown inthe table on the left.

Notes) • For the minimum PH at switch mounting, refer to thedimensional drawings of the TC type.

• For the TC type (with two switches), cylinder strokes incase that the TC type attachment shown in the figurebelow is positioned in the center are shown in the tableon the left.

Notes) • Figure in the parentheses in the line of bore 32 mmshown in the table on the left indicates the minimumstroke when the rod side detection switch and thehead side detection switch are mounted on the sameside.

3

Spacer

GasketG1/4

Mounting style

SD . LA . CA . CB . FA . FB . TC

EB

EA . TA

Order symbol

Port position

A (B . C . D)

A

A

Rod cover

Port position

A (B . C . D)

A

A

Valve position

B (C . D . A)

B

C

Head cover

Port position

A (B . C . D)

A

A

Valve position

B (C . D . A)

C

B

Valve position

B (C . D . A)

B

C

A

B

C

D

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

30

25

25

25

20

20

20

20

20

30 (40)

25

25

25

25

25

25

25

25

60

60

65

65

75

90

90

95

110

115

115

125

125

135

150

160

170

185

● Order symbols and port and cushion valve positions shown above are applicable to the EA, EB, and TAtypes.When changing any position, specify the position on the rod side or the head side.

As for the TA type rod cover, neither port nor cushion valve can be provided on the B or D side.As for the EA type rod cover, cushion valves cannot be provided on the B or D side.As for the EB type rod cover, cushion valves cannot be provided on the B or D side.

● If the cylinder has no cushion, cushion valve position is indicated as "0".● If the ports are located on the B or D side of the LA type cylinder and general piping joints are used, they

may interfere with the cylinder mounting bolts.● Air vents are located on the same side as that the cushion valves are installed.

If the cylinder has no cushion, they are located on the B side ( C side, in the case of the EA or TA type rod cover).● For details of positions of the ports, cushion valves, and air vents, refer to 31 page.

● The symbols A shown in the table above indicate the standard port positions of types other than EA, EB, and TA, and symbols Bindicate the standard cushion valve positions. When changing any position, write down symbols shown in dimensional drawings.

● Specification of change in positions of head side port and cushion valve

Head side port and cushion positionchange specification symbol

Head side port and cushion valve position

29

Port position and cushion valve position● Standard type: With both end cushions

Standard port position, cushion valve position

(Example)

Position specification: PC- BA

160H-1R 2CA50BB100- B A AH2

● Specification of change in positions of rod side port and cushion valve(Example)

Port G thread type● As for the port G thread type, add "G" ahead of the port position symbol.

(Example)

● Use the attached spacers and gaskets for the port G thread type cylinder with 32 mm bore.(If no spacer is attached to it, the joint may interfere with the parts in the cylinder.)

Port position

Cushion valve position

Port G thread type

Port position

Cushion valve position

Mounting style

Boremm

Switch quantity

Switch type

Types other than TC type

AX type

with a switch with two switches with a switch with two switches

AX type AX type AX type

TC type

Page 6: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinder

Weight table Unit: kg

Switch additional weight Unit: kg

0.05

0.07

0.09

0.13

0.15

0.17

0.04

0.06

0.08

φ32 - φ63

φ80 - φ140

φ160

Boremm

Rodtype

Basic weight (SD type)

Single rod type

Double rod type

Single rod type

Double rod type

Rod end eye (T-end)

Rod end clevis

(Y-end )

Lock nutLA EA EB FA FE FB CA CB TA TC

Additional weight per

1 mm strokeMounting accessories weight

Rod end attachment

weight

B

A

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

φ40

φ50

φ63

φ80

φ100

φ125

1.31

2.94

4.55

6.63

12.55

17.93

33.67

43.36

56.03

3.03

4.72

6.94

13.08

18.88

35.78

0.0062

0.0098

0.0146

0.0193

0.0316

0.0458

0.0738

0.0988

0.1181

0.0116

0.0177

0.0238

0.0384

0.0566

0.0934

0.0082

0.0127

0.0194

0.0272

0.0440

0.0650

0.1038

0.1380

0.1678

-

-

-

-

-

-

0.26

0.32

0.65

1.18

1.37

1.98

2.49

2.87

3.64

0.32

0.65

1.18

1.37

1.98

2.49

0.34

1.02

1.42

1.66

2.93

3.76

6.67

8.23

9.42

1.02

1.42

1.66

2.93

3.76

6.67

0.23

0.81

1.16

1.43

2.58

3.41

6.67

8.23

9.42

0.81

1.16

1.43

2.58

3.41

6.67

0.32

0.93

1.60

2.47

4.40

6.05

10.24

14.15

19.36

-

-

-

-

-

-

-

-

-

-

-

-

-

-

-

1.43

2.28

3.50

5.43

7.90

14.95

0.28

0.88

1.48

2.29

4.07

5.56

9.44

13.07

17.92

0.88

1.48

2.29

4.07

5.56

9.44

0.15

0.26

0.80

0.96

1.97

3.99

6.60

8.44

10.58

0.26

0.80

0.96

1.97

3.99

6.60

0.19

0.32

0.99

1.15

2.45

4.99

8.46

10.89

13.84

0.32

0.99

1.15

2.45

4.99

8.46

0.16

0.45

0.84

1.54

3.05

4.31

9.01

12.25

16.75

0.45

0.84

1.54

3.05

4.31

9.01

0.31

0.38

1.17

1.25

1.95

5.30

7.31

9.98

12.50

0.50

1.25

1.66

2.98

6.78

10.28

0.38

0.54

1.68

1.86

3.64

7.97

11.79

15.64

19.08

0.62

1.86

2.08

3.98

9.25

13.77

0.03

0.03

0.05

0.09

0.13

0.23

0.31

0.38

0.46

0.05

0.09

0.13

0.23

0.31

0.46

0.04

0.08

0.15

0.31

0.63

1.23

2.43

3.48

4.94

0.08

0.15

0.31

0.63

1.23

2.43

1.73

3.59

5.69

8.18

15.40

21.88

39.03

50.39

65.30

-

-

-

-

-

-

Long thread with lock nut

Note) When a lock nut is attached to the rod end, length "A"shown in the figure above must be the same as that ofthe long thread with lock nut type or longer. For details,refer to "Rod end attachment/Thread length with locknut".

Lock nut

A

30

Notes on order of cylinder with lock nut Delivery of rod end attachment (T-end and Y-end)

Semi-standard fabrication range

The rod end thread length (A) must be longer when alock nut is attached to the rod end.

● With boots● Change in position of TC attachment (Size sym-

bol: PH)● Change in piston rod end

(Size symbol: WF (W), A, KK)● Plated cylinder tube

(Hard chrome plated 2/100 mm)

For details, contact us.

Delivery specifications of the cylinder with lock nut androd end attachment differ from those of the cylinderwith rod end attachment only (without lock nut). Fordetails, refer to the dimensional drawing of rod end at-tachment.

160H-1 2LA50BB100- AB - K(Example)

AX • AZ typeSwitch

Bore (mm) Cord length 1.5 m Connector typeCord length 5 m

A without lock nutA=28

A of long threadwith lock nutA=40

Calculation formula cylinder weight (kg) = basic weight + (cylinder stroke mm × additional weight per 1 mm stroke) + (switchadditional weight × switch quantity) + mounting accessories weight + rod end attachment weight

Calculation example 160H-1R, bore φ80, rod B, cylinder stroke 200 mm, LA type, 2 pcs. of AX21512.55 + (0.0316 × 200) + 1.37 + (0.15 × 2) = 20.54 kg

Page 7: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder

● Other positions of port and cushion valve (bore from 50 mm to 160 mm)

Symbols AV : Air ventCV : Cushion valve

(With cushion)• When changing the positions of cushion

valves, turn them in the standard typeclockwise by 90° viewed from the front of therod.

(Without cushion)• Air vents are at the positions turned clockwise

from the port positions by 90° viewed from thefront of the rod.

• When changing positions of the ports andcushion valves on the rod side and head side,specify the positions on the rod side and headside, respectively.

● In all the mounting styles, cushion valves and air vents are located on the same side. When any change in theposition of air vent is required, contact us.

● If you need detailed dimensions of air vent positions, contact us.● Cylinders without cushion have no cushion valve. Positions of air vents depend on mounting style.

Positions of ports, cushion valves, and air vents (Rod B)

Double-acting type single rod/SD, FA, FB, CA, CB, TC types● Basic type (Port and cushion position: A • B Order symbol A B )

● Other positions of port and cushion valve (with 32 mm or 40 mm bore)In the basic type cylinders with 32 mm or 40 mm bore, positions of the cushion valves and air vents differ from those of thecylinder with a bore from 50 mm to 160 mm. When changing the positions of the cushion valves, turn them clockwise by 90°viewed from the front of the rod, in a similar manner to the cylinder with a bore from 50 mm to 160 mm. Positions of air vents arethe same as the above, even when the cylinder has no cushion.

Double-acting type single rod/EB type● Basic type (port, cushion position: Rod side A • B Head side A • B Order symbol A B )

Double-acting type single rod/EA type● Basic type (port, cushion position: Rod side: A • C Head side A • B Order symbol A C )

EA type cylinders with ports and cushion valves at positions other than basic ones are manufactured ondemand. When ordering them, give us directions separately. Positions of air vents are the same as the above,even when the cylinders have no cushion.

(φ32)

D

A

C

B

AV

AV

CV

CV

(φ40)

D

A

C

B

(φ50 - φ160)

D

A

C

B

(φ32)

D

A

C

B

AV AV

CV

CV

(φ40)

D

A

C

B

(φ50 - φ160)

D

A

C

B

(φ32)

D

A

C

B

AV

CV

CV

AV

(φ40)

D

A

C

B

CV

AV

CV

AV

(φ50 - φ160)

D

A

C

B

CV

AV

CV

AV

Cushion valve position

B C D A 0 (without cushion)

A

B

C

D

Portposition

Port

AV

CV

Standardtype

D

A

C

B

31

EA type cylinders with ports and cushion valves at positions other than basic ones are manufactured ondemand. When ordering them, give us directions separately. Positions of air vents are the same as the above,even when the cylinders have no cushion.

Page 8: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinder

Double-acting type single rod/LA type

Double-acting type single rod/TA type

● Other positions of port and cushion valve (with 80 mm or 160 mm bore)

CV

AV

(φ80 - φ160)(φ63)

(φ40, φ50)(φ32)

D

A

C

B

AV

CV

B C D A

A

B

C

D

D

A

C

B

Cushion valve position

0 (without cushion)

Por

t pos

ition

Port

(With cushion)• Port position A, C: The port is positioned on

the axis line (without offset)Port position B, D: The port is offset from theaxis center upward by the distances shownbelow.

φ32, φ40 ............ 5.5mmφ50 ................... 6.5mmφ63, φ80 ............ 12mmφ100 ................. 15mmφ125 - φ160 ........ 0

• Change in cushion valve position (shown indrawings on the left side)

Position A: Same as the cushion valveposition A of the SD type

Position B: Basic positionPosition C: Turn the position B clockwise

by 90° viewed from the frontof the position B.

Position D: Line symmetric with respect tothe position B

• Cushion valves on the B or D side are offsetupward to prevent interference with themounting bolts.

(Without cushion)• When ports are located on the A side: The air

vent is on the B side.• When a port is located on the B, C, or D side:

The air vent is on the A side.(If you need to change the location, contactus.)

Double-acting double rod type

● The ports can be located on the A side only.● The cushion valve and air vent are located on the side

opposite to the ports.● On the head side, the port cushions can be located on

the A or B side.

(With cushion) (Without cushion)

(Without cushion)(With cushion)Locations of the ports and valves are thesame as those of the double-acting singlerod type.

The air vent on the rod sideis located on the sidesymmetric with the headside.

AVCV AV

Air vent on head side

Air vent on rod side

D

A

C

B

● Basic type (Standard port and cushion position: A • B Order symbol A B )

● Other positions of port and cushion valve (with 32 mm or 63 mm bore)

32

● Standard port and cushion position: A • C Order symbol A C

In the basic type cylinders with 32 mm or 63 mm bore, positions of the cushionvalves and air vents differ from those of the cylinder with a bore from 80 mm to 160mm. When changing the positions of the cushion valves, turn them clockwise by 90°viewed from the front of the rod, in a similar manner to the cylinder with a bore from80 mm to 160 mm. Positions of air vents are the same as the above, even when thecylinder has no cushion.

Page 9: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder

Double-acting single rod type/SD, FE, FB, CA, CB, TC types

● Other positions of port and cushion valve (on the rod side)

Double-acting single rod type/EA types

Turn the positions of the port and cushion valve of the basic type clockwise by 90° viewed from the front of the rod.On the head side, the air vent is at the same position as that of the rod B type.If the cylinder has no cushion, the air vents are installed to the cushion valve positions of the type with cushions. (Threepositions)

Symbols AV : Air ventCV : Cushion valve

● Other positions of port and cushion valve (on the rod side)

Turn the positions of the port and cushion valve of the basic type clockwise by 90° viewed from the front of the rod.On the head side, the air vent is at the same position as that of the rod B type.If the cylinder has no cushion, the air vents are installed to the cushion valve positions of the type with cushions. (Threepositions)

CV

D

A

C

B

Rod sideair vent Rod side air vent

Positions of the ports, cushion valves, and airvents on the head side are the same as thoseof the rod B type.

● Locations of the ports, cushion valves, and air vents of the EB type cylinder are the same as those of the rod Btype.

Locations of ports, cushion valves, and air vents (Rod A)

● Basic type (Standard port and cushion valve positions: A • C Order symbol A C )

● Basic type (Standard port and cushion valve positions: A • B Order symbol A B )

33

CV

CV

AV

Rod side air vent

D

A

C

B

Positions of the ports, cushion valves, and air vents on the head side are the same as those of the rod B type.

Page 10: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinder

Double-acting single rod/LA type

● Other positions of ports and cushion valve (on the rod side)

Double-acting single rod/ TA type

The combinations of cushion valve position and port position shown in the figures below are applicable. The air vents can belocated on the two sides neither the port nor the cushion valve is located. Note that the ports and the cushion valve cannot belocated on the same side.

(φ40 - φ125)

CV

D

A

C

B

Rod side air vent

Positions of the ports, cushion valves, and air vents on the head side are the same as those of the rod B type.

Port D

Port C

Port B

Port A

Cushion valve on the side A

Cushion valve on the side B

Cushion valve on the side C

Cushion valve on the side D D

A

C

B D

A

C

B

Air vent

Port

Cushion valve

D

A

C

B

Example (Positions of ports and cushion valve: B , C )

● Basic type (Standard port and cushion valve positions: A • B Order symbol: A B )

The cushion valve and air vents are located on the side opposite to that the ports are located.

34

Standard port and cushion valve positions: A • C Order symbol: A C )

Page 11: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

SD

WW

WF

Set attachment

160H-1 2 SD Bore B B Stroke - A B

FF

AE

DE

(AA)

OF

ZJ+stroke

KK

VD

S

B

4-DD

BB

YA

SL

WF

PLPJ+stroke

FP 2-EEAir vent

Cushion valve

H+strokeTG G J

E Max. 8 HL+stroke

MM

Port G thread type

D

A

C

B

Drill holes in case of Rod dia. 90 mm.

OF

2-φ12

WF FP

2-EE

OFOF

KKKK

ZM+stroke×2

ZK+stroke

AWF+strokeFPA

MM

Air vent

Air ventG

LZ+stroke

Cushion valve

HM+strokeG

PK+stroke

MM

● Positions of the cushion valves and air ventsdepend on the cylinder bore.

● Rod end thread length (A) must be longerwhen a lock nut is attached to the rod end.Refer to "Rod end attachment/Rod end threadlength with lock nut".

● For the use of the SD type, be sure to refer tothe "Precautions for use, 4. Mounting" in thebeginning of this catalogue.

● On the rod side of the rod A type cylinder, theair vents are located on the two sides neitherthe port nor the cushion valve is located.

● When you want to change the length of theprojected rod, specify the "WF".

● For the mounting of switches, refer to the di-mensional drawings of "Switch set". All thecontents other than “switch mounting dimen-sions” are identical.

Double-acting double rod (Rod B)

● Distance between the covers of the double rod type cylinder islonger than that of the single rod type cylinder by 10 mm.

With boots

Nylon tarpaulin f32·f40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - f160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xf125 - f160 1/3.5 Stroke+X

● When the calculated WF has decimals, raise them to the next whole number.

WFRod B

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 - f80 1/4 Stroke+X

f100·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

Rod A

35

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Page 12: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

Dimensional table

With boots

WW

X

Rod B

Rod A

Rod B

Rod A

φ40

-

56

-

φ50

φ50

61

64

φ50

φ71

64

77

φ71

φ80

77

80

φ80

φ100

80

82

φ100

φ100

82

94

φ100

φ140

94

102

φ125

-

97

-

φ140

-

102

-

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

Rod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

B

φ30 f9

φ34 f9

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ98 f9

φ108 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VD

10

10

9

9

8

8

6

5

5

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

Rod A

A

-

28

36

45

56

63

85

-

-

B

-

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ108 f9

-

-

MM

-

φ28

φ36

φ45

φ56

φ70

φ90

-

-

OF

-

φ26

φ34

φ43

φ54

φ68

φ88

-

-

S

-

22

30

38

50

60

80

-

-

SL

-

11

14

17

21

24

Drill hole

-

-

VD

-

9

9

8

8

6

5

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

47

59

74

91

117

137

178

200

219

12

12

14

14

16

16

18

18

18

7

9

13

13

16

16

21

22

25

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

35

37

42

39

46

47

51

51

54

49

54

60

59

70

74

82

82

87

28

39

38

40

45

47

55

62

64

103

128

134

136

159

168

197

203

213

38

49

48

50

55

57

65

72

74

26

35

36

37

44

47

60

59

62

136

157

168

168

195

205

229

236

248

56

73

74

80

93

101

117

124

130

66

83

84

90

103

111

127

134

140

12

18

18

17

20

20

29

28

29

33.2

41.7

52.3

64.3

82.7

96.9

125.9

141.4

154.9

25

25

25

32

31

35

35

35

32

60

62

67

71

77

82

86

86

86

128

153

159

168

190

203

232

238

245

161

182

193

200

226

240

264

271

280

186

207

218

232

257

275

299

306

312

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AA AE BB DE E FP G HEE FFDD

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

HL HM J LZ PJ PK PL WF Y ZJ ZK ZMTG

M6×1

M8×1

M12×1.25

M12×1.25

M16×1.5

M16×1.5

M22×1.5

M24×1.5

M27×2

• Allowance of MM is f8.

45

62

75

90

114

130

165

185

205

Symbol

Bore

Symbol

Bore

Symbol

Bore

36

Page 13: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

LA160H-1 2 LA Bore B B Stroke - A B

● Positions of the cushion valves and air vents depend on thecylinder bore.

● Rod end thread length (A) must be longer when a lock nut isattached to the rod end. Refer to "Rod end attachment".

● Notes on mounting bolts of cylinder with a bore of 100 mm orlongerUse bolts with hexagonal hole as the mounting bolts.If hexagonal bolts are used, bolt heads may interfere with thecover or spot facing, causing failure in mounting.When using a washer, use of a disc spring for bolt with hexago-nal hole is recommended.If a flat washer or spring washer is used, it may interfere withthe cover or spot facing, causing failure in mounting.

● When the cylinder bore ranges 32 mm to 80 mm, hexagonalbolts, bolts with hexagonal hole, and flat washers can be used.

● On the rod side of the rod A type cylinder, the air vents are lo-cated on the two sides neither the port nor the cushion valve islocated.

● When you want to change the length of the projected rod, specifythe "WF".

● As for the dimensions other than those shown in the drawings,refer to the pages related to the SD type (basic type).

● For the mounting of switches, refer to the dimensional drawingsof "Switch set". All the contents other than “switch mountingdimensions” are identical.

Double-acting double rod (Rod B)

EH

LH

SY SX

FF

AE

DE

BBZJ+stroke

4-SB

XS

MM OF

SZ

Bore from 32 mm to 80 mm, 4 max.Bore from 100 mm to 160 mm, 2 max.E

XB+stroke

TS

Cushion valve

Air vent2-EE

FP PJ+stroke PLWF

SL

A

SW

B

S

VD

KK

US

ST

SS+stroke

D

A

C

B

OF

2-φ12

Drill holes in case of Rod dia. 90 mm.

Port G thread type

SY SYSXSX

OFMM

FP

OF

PK+stroke

XS+strokeSV+strokeXS

MM

A FP WF+stroke AWF

KK KK

● Distance between the covers of the double rod type cylinder islonger than that of the single rod type cylinder by 10 mm.

With boots

37

WW

WF

Set attachment

Nylon tarpaulin f32·f40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - f160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xf125 - f160 1/3.5 Stroke+X

● When the calculated WF has decimals, raise them to the next whole number.

WFRod B

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 - f80 1/4 Stroke+X

f100·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

Rod A

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Page 14: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

With boots

Dimensional tableRod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

B

φ30 f9

φ34 f9

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ98 f9

φ108 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VD

10

10

9

9

8

8

6

5

5

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

Rod A

A

-

28

36

45

56

63

85

-

-

B

-

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ108 f9

-

-

MM

-

φ28

φ36

φ45

φ56

φ70

φ90

-

-

OF

-

φ26

φ34

φ43

φ54

φ68

φ88

-

-

S

-

22

30

38

50

60

80

-

-

SL

-

11

14

17

21

24

Drill hole

-

-

VD

-

9

9

8

8

6

5

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

Symbol

Bore

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

12

12

14

14

16

16

18

18

18

7

9

13

13

16

16

21

22

25

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

φ9

φ11

φ14

φ18

φ18

φ26

φ26

φ33

φ33

73

98

92

86

105

102

131

130

130

12.5

12.5

19

26

26

32

32

38

38

96

117

110

102

121

117

141

146

140

16

25

23

20

27

25

38

31

33

29

34

31

26

30

28

35

35

28

20

20

29

33

34

41

40

42

49

10

10

13

17

17

22

22

28

29

63

83

102

124

149

172

210

240

260

84

103

127

161

186

216

254

298

318

25

25

25

32

31

35

35

35

32

118

143

146

151

173

181

210

210

216

45

45

54

65

68

79

79

80

86

128

153

159

168

190

203

232

238

245

45

62

75

90

114

130

165

185

205

56

73

74

80

93

101

117

124

130

35

37

42

39

46

47

51

51

54

44.5

62

74.5

89

114

128

164.5

184.5

203.5

66

83

84

90

103

111

127

134

140

22

31

37

44

57

63

82

92

101

0

0

0

0

0

0

0

0

0

-0.084

-0.100

-0.100

-0.100

-0.120

-0.120

-0.140

-0.140

-0.140

12

18

18

17

20

20

29

28

29

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AE BB DE E EE EH FF FP LH PK PLPJ SB SS ST SV SW SX SY SZ TS US WF XB XS ZJ

• Allowance of MM is f8.

Symbol

Bore

● Notes on LA type with ports on lateral side ( B or D side)● The port G thread type is not the standard type. (When the bore is not less

than 40 mm, position on the A or C side is the same as that of the standardtype.)

● Positions of the ports are deviated from the cylinder center by the distance LE.● Take into consideration the interference of the piping and joint with the mounting

bolts (including handling of tightening tools), referring to the table on the right.

● When the cylinder bore is between 32 mm and 80 mm, mounting withhexagonal bolts is recommended. If bolts with hexagonal hole are used, boltheads or tightening tool (Allen key wrench) may interfere with the piping or joint,causing failure in mounting or tightening.

● When the cylinder bore is 100 mm or longer, hexagonal bolts cannot be used(because the head of a hexagonal bolt may interfere with the cover or spotfacing). Thus, in such a case, use bolts with hexagonal hole, and mount thecylinder by tightening nuts on the back of the mounting plate (refer to thedrawing on the right side).

PortEE LE LP

Mounting boltM

Spot facing dia.

SE P Note1

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

5.5

5.5

6.5

12

12

15

0

0

0

15

24

24.5

30

44

47

51

55

64

M8

M10

M12

M16

M16

M24

M24

M30

M30

18

21

27

34

31

39

39

50

50

20

21

26

36

36

43

45

51

57

Rc 1/4

Rc 3/8

Rc 1/2

Rc 1/2

Rc 3/4

Rc 3/4

Rc 1

Rc 1

Rc 1

Note1. When determining the length P, interference of joints with mounting bolts must be taken into consideration.

Symbol

Bore

WW

X

Rod B

Rod A

Rod B

Rod A

φ40

-

56

-

φ50

φ50

61

64

φ50

φ71

64

77

φ71

φ80

77

80

φ80

φ100

80

82

φ100

φ100

82

94

φ100

φ140

94

102

φ125

-

97

-

φ140

-

102

-

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

Whole surface processed

SE/2

Mounting bolt M

Piping, joint P

LE

EE when the ports are located on the side

EE when the ports are located on the side

LP

SE spot facing

D

D A

C

B

B Bore from 32 mm to 63 mmWithout spot facing, with the whole surface processed

Nut

Mounting plate

Cylinder Mounting bolt

Piping, joint

38

Page 15: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

EA160H-1 2 EA Bore B B Stroke - A B

● Positions of the cushion valves and air vents dependon the cylinder bore.

● Rod end thread length (A) must be longer when alock nut is attached to the rod end. Refer to "Rodend attachment/Rod end thread length with lock nut".

● If the mounting plate is located on the cylinder tubeside of the switch set cylinder, take into consider-ation the interference of the switch with the mount-ing plate.

● On the rod side of the rod A type cylinder, the airvents are located on the two sides neither the portnor the cushion valve is located.

● When you want to change the length of the projectedrod, specify the "WF".

● As for the dimensions not shown in these drawings,refer to the SD type (basic type).

● For the mounting of switches, refer to the dimen-sional drawings of "Switch set". All the contents otherthan “switch mounting dimensions” are identical.

Double-acting double rod (Rod B)

FF

AE

DE

BBHF+stroke

4-FB

(Head side)8, max.

(Rod side)8, max.

(Head cover)E

LL+stroke

WE

VD

VE

F

FG

RD

OFE R

UO

TO

KK

S

B

YA

WF

SL

PLPJ+stroke

2-EE

MMD

A

C

B

OF

2-φ12

Drill holes in case of Rod dia. 90 mm. Port G thread type

Air vent

Air vent

Cushion valve

Y+stroke

WF+stroke

ZR+stroke×2

ZL+stroke

WE

OF OF

KKKK

AA

MM

PK+strokeY

MM

WW

WF

20, max.

BABA

Set attachment

Set attachment

● Distance between the covers of the double rod type cylinder islonger than that of the single rod type cylinder by 10 mm.

With boots

39

Nylon tarpaulin f32·f40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - ff160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xf125 - f160 1/3.5 Stroke+X

● When the calculated WF has decimals, raise them to the next whole number.

WFRod B

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 - f80 1/4 Stroke+X

f100·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

Rod A

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Note) Take into consideration the interference of the set attachmentwith the mounting plate.

Page 16: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

With boots

Dimensional tableRod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

B

φ30 f9

φ34 f9

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ98 f9

φ108 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

RD

φ42 f8

φ62 f8

φ74 f8

φ82 f8

φ92 f8

φ105 f8

φ125 f8

φ140 f8

φ150 f8

RD

-

φ62 f8

φ74 f8

φ88 f8

φ105 f8

φ125 f8

φ150 f8

-

-

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VD

10

10

9

9

8

8

6

5

5

VE

20

20

25

25

28

30

28

28

30

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

Rod A

A

-

28

36

45

56

63

85

-

-

B

-

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ108 f9

-

-

MM

-

φ28

φ36

φ45

φ56

φ70

φ90

-

-

OF

-

φ26

φ34

φ43

φ54

φ68

φ88

-

-

S

-

22

30

38

50

60

80

-

-

SL

-

11

14

17

21

24

Drill hole

-

-

VD

-

9

9

8

8

6

5

-

-

VE

-

19

25

24

28

28

27

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

12

12

14

14

16

16

18

18

18

7

9

13

13

16

16

21

22

25

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

10

10

16

16

20

22

22

23

25

φ6.6

φ11

φ14

φ14

φ18

φ18

φ22

φ26

φ26

39

44

44

43

50

52

60

59

62

93

118

118

120

139

146

175

180

188

45

62

75

90

114

130

165

185

205

54

74

74

77

89

94

115

121

126

56

73

74

80

93

101

117

124

130

66

83

84

90

103

111

127

134

140

12

18

18

17

20

20

29

28

29

33

41

52

65

83

97

126

142

155

58

87

105

117

149

162

208

230

253

70

110

130

145

180

200

250

280

300

25

25

25

32

31

35

35

35

32

35

35

41

48

51

57

57

58

57

60

62

67

71

77

82

86

86

86

126

147

152

152

175

183

207

213

223

151

172

177

184

206

218

242

248

255

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AE BB DE E F FB FG HFEE FF

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

LL

PJ PK PL R TO UO WE WF Y ZL ZR

• Allowance of MM is f8.

Symbol

Bore

Symbol

Bore

Symbol

Bore

WW

X

BA

Rod B

Rod A

Rod B

Rod A

Rod B

Rod A

φ40

-

56

-

φ34

-

φ50

φ50

61

64

φ40

φ46

φ50

φ71

64

77

φ46

φ55

φ71

φ80

77

80

φ55

φ65

φ80

φ100

80

82

φ65

φ77

φ100

φ100

82

94

φ77

φ92

φ100

φ140

94

102

φ92

φ112

φ125

-

97

-

φ103

-

φ140

-

102

-

φ112

-

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

40

Page 17: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

EB

WW

WF

Set attachment

160H-1 2 EB Bore B B Stroke - A B

● Positions of the cushion valves and air vents depend on the cylin-der bore.

● Rod end thread length (A) must be longer when a lock nut is at-tached to the rod end. Refer to "Rod end attachment/Rod endthread length with lock nut".

● If the mounting plate is located on the cylinder tube side of theswitch set cylinder, take into consideration the interference of theswitch with the mounting plate.

● On the rod side of the rod A type cylinder, the air vents are locatedon the two sides neither the port nor the cushion valve is located.

● When you want to change the length of the projected rod, specifythe "WF".

● As for the dimensions not shown in these drawings, refer to theSD type (basic type).

● For the mounting of switches, refer to the dimensional drawingsof "Switch set". All the contents other than “switch mounting di-mensions” are identical.

HB+stroke

FF

AE

DE

4-FB

(Rod cover)E

KK

VD

S

B

A

SL

WF PLPJ+strokeFP

2-EE

ZJ+stroke

J

OFMM

TO

UO

R ED

A

C

B

OF

2-φ12

Drill holes in case of Rod dia. 90 mm.

Air vent

Air ventCushion valve

Port G thread type

(Rod side)8, max.

(Head side)8, max.

With boots

41

Nylon tarpaulin f32·f40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - f160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xf125 - f160 1/3.5 Stroke+X

● When the calculated WF has decimals, raise them to the next whole number.

WFRod B

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 -f80 1/4 Stroke+X

f100·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

Rod A

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Page 18: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

With boots

WW

X

Rod B

Rod A

Rod B

Rod A

φ40

-

56

-

φ50

φ50

61

64

φ50

φ71

64

77

φ71

φ80

77

80

φ80

φ100

80

82

φ100

φ100

82

94

φ100

φ140

94

102

φ125

-

97

-

φ140

-

102

-

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

Dimensional table

Rod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

B

φ30 f9

φ34 f9

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ98 f9

φ108 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VD

10

10

9

9

8

8

6

5

5

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

Rod A

A

-

28

36

45

56

63

85

-

-

B

-

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ108 f9

-

-

MM

-

φ28

φ36

φ45

φ56

φ70

φ90

-

-

OF

-

φ26

φ34

φ43

φ54

φ68

φ88

-

-

S

-

22

30

38

50

60

80

-

-

SL

-

11

14

17

21

24

Drill hole

-

-

VD

-

9

9

8

8

6

5

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

12

12

14

14

16

16

18

18

18

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

φ6.6

φ11

φ14

φ14

φ18

φ18

φ22

φ26

φ26

45

62

75

90

114

130

165

185

205

35

37

42

39

46

47

51

51

54

102

118

123

131

146

156

172

179

183

26

35

36

37

44

47

60

59

62

56

73

74

80

93

101

117

124

130

12

18

18

17

20

20

29

28

29

33

41

52

65

83

97

126

142

155

58

87

105

117

149

162

208

230

253

70

110

130

145

180

200

250

280

300

25

25

25

32

31

35

35

35

32

128

153

159

168

190

203

232

238

245

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AE DE E FB FPEE FF

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

HB

J PJ PL R TO UO WF ZJ

• Allowance of MM is f8.

Symbol

Bore

Symbol

Bore

Symbol

Bore

42

Page 19: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

FA160H-1 2 FA Bore B B Stroke - B B

● Positions of the cushion valves and airvents depend on the cylinder bore.

● Rod end thread length (A) must belonger when a lock nut is attached tothe rod end. Refer to "Rod end attach-ment/Rod end thread length with locknut".

● When you want to change the length ofthe projected rod, specify the "W".

● As for the dimensions not shown inthese drawings, refer to the SD type (ba-sic type).

● For the mounting of switches, refer tothe dimensional drawings of "Switchset". All the contents other than “switchmounting dimensions” are identical.

Double-acting double rod (Rod B)

● Distance between the covers of the double rod type cylinder islonger than that of the single rod type cylinder by 10 mm.

With boots

WW

W

Set attachment

Set attachment

20, max.

BABA

MM

E2-EE

FP PJ+stroke PL

SLA

BA

S

KK

OF

DE

AE

FF

F

W

TO

UO

RFE

HL+stroke

BBHN+stroke

VF

4-FB

OF

2-φ12

D

A

C

B

Drill holes in case of Rod dia. 90 mm. Port G thread type

Air vent

Cushion valve

8, max.

MM

PK + stroke

Air ventCushion valve

LZ + stroke

Air vent

MM

A FP WF + stroke A

KK KK

OF OF

2-EE

FPW F

VF

VD

43

Nylon tarpaulin f32·f40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - f160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xf125 - f160 1/3.5 Stroke+X

● When the calculated W has decimals, raise them to the next whole number.

WRod B

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Note) Take into consideration the interference of the set attachmentwith the mounting plate.

Page 20: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

Dimensional table

With boots

WW

X

BA

Rod B

Rod B

Rod B

φ40

45

φ34

φ50

45

φ40

φ50

45

φ46

φ71

55

φ55

φ80

55

φ65

φ100

55

φ77

φ100

65

φ92

φ125

65

φ103

φ140

65

φ112

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

Rod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

BA

φ34 f9

φ40 f9

φ46 f9

φ55 f9

φ65 f9

φ77 f9

φ92 f9

φ103 f9

φ112 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VF

13

13

13

13

13

13

13

13

13

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

VD

10

10

9

9

8

8

6

5

5

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

7

9

13

13

16

16

21

22

25

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

φ6.6

φ11

φ14

φ14

φ18

φ18

φ22

φ26

φ26

45

62

75

90

114

130

165

185

205

47

64

77

92

116

132

167

187

207

11

16

19

22

25

27

29

32

37

103

128

134

136

159

168

197

203

213

114

144

153

158

184

195

226

235

250

56

73

74

80

93

101

117

124

130

66

83

84

90

103

111

127

134

140

12

18

18

17

20

20

29

28

29

33

41

52

65

83

97

126

142

155

58

87

105

117

149

162

208

230

253

70

110

130

145

180

200

250

280

300

35

35

41

48

51

57

57

58

57

25

25

25

32

31

35

35

35

32

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AE BB DE E FEFBFEE FF

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

HL HN

136

157

168

168

195

205

209

236

248

LZ PJ PK PL R UO W WFTO

35

37

42

39

46

47

51

51

54

FP

12

12

14

14

16

16

18

18

18

Symbol

Bore

Symbol

Bore

Symbol

Bore

• Allowance of MM is f8.

44

Page 21: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

FE160H-1 2 FE Bore A B Stroke - A B

● Positions of the cushion valves and air vents depend on the cylinder bore.● Rod end thread length (A) must be longer when a lock nut is attached to the

rod end. Refer to "Rod end attachment/Rod end thread length with locknut".

● On the rod side of the rod A type cylinder, the air vents are located on thetwo sides neither the port nor the cushion valve is located.

● When you want to change the length of the projected rod, specify the "W".● As for the dimensions not shown in these drawings, refer to the SD type

(basic type).● For the mounting of switches, refer to the dimensional drawings of "Switch

set". All the contents other than “switch mounting dimensions” are identical.

With boots

MM

E2-EE

FP PJ+stroke PL

SLA

BA

S

KK

OF

DE

AE

FF

FY

W

TO

UO

RFE

HL+stroke

BBHY+stroke

VF

4-FB

D

A

C

B

OF

2-φ12

Drill holes in case of Rod dia. 90 mm. Port G thread type

Air vent

Cushion valve

8, max.

WW

W

20, max.

BABA

Set attachment

Set attachment

45

● When the calculated WF has decimals, raise them to the next whole number.

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 - f80 1/4 Stroke+X

f100·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

WRod A

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Note) Take into consideration the interference of the set attachmentwith the mounting plate.

Page 22: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

Dimensional table

With boots

WW

X

BA

Rod A

Rod A

Rod A

φ50

45

φ46

φ71

55

φ55

φ80

55

φ65

φ100

55

φ77

φ100

65

φ92

φ140

65

φ112

φ40 φ50 φ63 φ80 φ100 φ125Symbol

Bore

φ40

φ50

φ63

φ80

φ100

φ125

Rod A

A

28

36

45

56

63

85

BA

φ46 f9

φ55 f9

φ65 f9

φ77 f9

φ92 f9

φ112 f9

MM

φ28

φ36

φ45

φ56

φ70

φ90

OF

φ26

φ34

φ43

φ54

φ68

φ88

S

22

30

38

50

60

80

SL

11

14

17

21

24

Drill hole

VF

13

13

13

13

13

13

KK

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

φ40

φ50

φ63

φ80

φ100

φ125

12

14

14

16

16

18

9

13

13

16

16

21

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ11

φ14

φ14

φ18

φ18

φ22

62

75

90

114

130

165

64

77

92

116

132

167

19

22

25

27

29

37

37

42

39

46

47

51

128

134

136

159

168

197

147

156

161

186

197

234

73

74

80

93

101

117

18

18

17

20

20

29

41

52

65

83

97

126

87

105

117

149

162

208

110

130

145

180

200

250

35

41

48

51

57

57

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

G3/8

G1/2

G1/2

G3/4

G3/4

G1

AE BB DE E FEFBFYEE FF

φ40

φ50

φ63

φ80

φ100

φ125

FP HL HY PJ PL R UO WTO

• Allowance of MM is f8.

Symbol

Bore

Symbol

Bore

Symbol

Bore

46

Page 23: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

FB160H-1 2 FB Bore B B Stroke - A B

● Positions of the cushion valves and air vents de-pend on the cylinder bore.

● Rod end thread length (A) must be longer whena lock nut is attached to the rod end. Refer to"Rod end attachment/Rod end thread length withlock nut".

● On the rod side of the rod A type cylinder, the airvents are located on the two sides neither theport nor the cushion valve is located.

● When you want to change the length of the pro-jected rod, specify the "WF".

● As for the dimensions not shown in these draw-ings, refer to the SD type (basic type).

● For the mounting of switches, refer to the dimen-sional drawings of "Switch set". All the contentsother than “switch mounting dimensions” areidentical.

With boots

MM

HL+stroke

2-EE

FP PJ+stroke PLWF

SL

A

B

S

VD

KK

OF

DE

AE

FF

TO

E

FE

UO

R

F

ZF+stroke

4-FB

OF

2-φ2

D

A

C

B

Drill holes in case of Rod dia. 90 mm. Port G thread type

8, max.

Air vent

Cushion valve

WW

WF

Set attachment

Nylon tarpaulin f32·f40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - f160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xf125 - f160 1/3.5 Stroke+X

● When the calculated WF has decimals, raise them to the next whole number.

WFRod B

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 - f80 1/4 Stroke+X

f100·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

Rod A

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

47

Page 24: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

WW

X

Rod B

Rod A

Rod B

Rod A

φ40

-

56

-

φ50

φ50

61

64

φ50

φ71

64

77

φ71

φ80

77

80

φ80

φ100

80

82

φ100

φ100

82

94

φ100

φ140

94

102

φ125

-

97

-

φ140

-

102

-

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

Rod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

B

φ30 f9

φ34 f9

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ98 f9

φ108 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VD

10

10

9

9

8

8

6

5

5

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

Rod A

A

-

28

36

45

56

63

85

-

-

B

-

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ108 f9

-

-

MM

-

φ28

φ36

φ45

φ56

φ70

φ90

-

-

OF

-

φ26

φ34

φ43

φ54

φ68

φ88

-

-

S

-

22

30

38

50

60

80

-

-

SL

-

11

14

17

21

24

Drill hole

-

-

VD

-

9

9

8

8

6

5

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

φ6.6

φ11

φ14

φ14

φ18

φ18

φ22

φ26

φ26

45

62

75

90

114

130

165

185

205

47

64

77

92

116

132

167

187

207

11

16

19

22

25

27

29

32

37

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AE DE E FEFBFEE FF

12

12

14

14

16

16

18

18

18

35

37

42

39

46

47

51

51

54

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

FP

103

128

134

136

159

168

197

203

213

HL

56

73

74

80

93

101

117

124

130

PJ

12

18

18

17

20

20

29

28

29

PL

33

41

52

65

83

97

126

142

155

R

58

87

105

117

149

162

208

230

253

TO

70

110

130

145

180

200

250

280

300

UO

25

25

25

32

31

35

35

35

32

WF

139

169

178

190

215

230

261

270

282

ZF

• Allowance of MM is f8.

Symbol

Bore

Symbol

Bore

Symbol

Bore

48

With boots

Dimensional table

Page 25: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

CA

WW

WF

Set attachment

160H-1 2 CA Bore B B Stroke - A B

● Positions of the cushion valves and air vents depend on the cylinder bore.● Rod end thread length (A) must be longer when a lock nut is attached to

the rod end. Refer to "Rod end attachment/Rod end thread length withlock nut".

● Bush (made of gray iron cast) is press-fit to the mounting hole (dimen-sional symbol: CD).

● On the rod side of the rod A type cylinder, the air vents are located on thetwo sides neither the port nor the cushion valve is located.

● When you want to change the length of the projected rod, specify the"WF".

● As for the dimensions not shown in these drawings, refer to the SD type(basic type).

● For the mounting of switches, refer to the dimensional drawings of "Switchset". All the contents other than “switch mounting dimensions” are identi-cal.

HC+stroke

FF

AE

DE

E

KK

VD

S

B

A

SL

WF PMPJ+strokeFP

2-EE

XC+stroke

ZC+stroke

FL

L

OFMM

EW

CD

MR

D

A

C

B

OF

2-φ12

Drill holes in case of Rod dia. 90 mm. Port G thread type

8, max.

Air vent

Cushion valve

EW

FL

CD

MR

● Bore 32 mm, 40 mm

With boots

49

Nylon tarpaulin f32·f40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - f160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xf125 - f160 1/3.5 Stroke+X

● When the calculated WF has decimals, raise them to the next whole number.

WFRod B

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 - f80 1/4 Stroke+X

f100·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

Rod A

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Page 26: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

WW

X

Rod B

Rod A

Rod B

Rod A

φ40

-

56

-

φ50

φ50

61

64

φ50

φ71

64

77

φ71

φ80

77

80

φ80

φ100

80

82

φ100

φ100

82

94

φ100

φ140

94

102

φ125

-

97

-

φ140

-

102

-

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

Rod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

B

φ30 f9

φ34 f9

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ98 f9

φ108 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VD

10

10

9

9

8

8

6

5

5

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

Rod A

A

-

28

36

45

56

63

85

-

-

B

-

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ108 f9

-

-

MM

-

φ28

φ36

φ45

φ56

φ70

φ90

-

-

OF

-

φ26

φ34

φ43

φ54

φ68

φ88

-

-

S

-

22

30

38

50

60

80

-

-

SL

-

11

14

17

21

24

Drill hole

-

-

VD

-

9

9

8

8

6

5

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

Symbol

Bore

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

φ12 H9

φ14 H9

φ20 H9

φ20 H9

φ28 H9

φ36 H9

φ45 H9

φ50 H9

φ56 H9

45

62

75

90

114

130

165

185

205

56

73

74

80

93

101

117

124

130

35

37

42

39

46

47

51

51

54

103

128

133

135

157

166

192

200

208

-

-

30

30

35

51

54

57

60

R17

R17

R28

R28

R33

R49

R52

R55

R58

25

25

25

32

31

35

35

35

32

147

172

191

200

229

257

289

300

308

164

189

219

228

262

306

341

355

366

16

20

30

30

40

50

60

65

70

0

0

0

0

0

0

0

0

0

-0.43

-0.52

-0.52

-0.52

-0.62

-0.62

-0.74

-0.74

-0.74

12

18

17

16

18

18

24

25

24

19

19

33

33

41

56

62

65

68

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AE CD DE E EE EW FF FL

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

FP HC L MR PJ PM WF XC ZC

12

12

14

14

16

16

18

18

18

• Allowance of MM is f8.

Symbol

Bore

Symbol

Bore

50

With boots

Dimensional table

Page 27: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

CB

WW

WF

Set attachment

160H-1 2 CB Bore B B Stroke - A B

● Positions of the cushion valves and air vents depend on the cylin-der bore.

● Rod end thread length (A) must be longer when a lock nut is at-tached to the rod end. Refer to "Rod end attachment/Rod endthread length with lock nut".

● On the rod side of the rod A type cylinder, the air vents are locatedon the two sides neither the port nor the cushion valve is located.

● When you want to change the length of the projected rod, specifythe "WF".

● As for the dimensions not shown in these drawings, refer to theSD type (basic type).

● For the mounting of switches, refer to the dimensional drawingsof "Switch set". All the contents other than “switch mounting di-mensions” are identical.

HC+stroke

FF

AE

DE

E

KK

VD

S

B

A

SL

WF PMPJ+strokeFP

2-EE

XC+stroke

ZC+stroke

FL

OFMM

CB

UB

CD

MR

With pin

D

A

C

B

L

OF

2-φ12

Drill holes in case of Rod dia. 90 mm. Port G thread type

8, max.

Air vent

Cushion valve

CB

UB

CD

MR

FL

● Bore 32 mm, 40 mm

With boots

51

Nylon tarpaulin f32ÅEf40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - f160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xff125 - f160 1/3.5 Stroke+X

● When the calculated WF has decimals, raise them to the next whole number.

WFRod B

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 - f80 1/4 Stroke+X

f100·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

Rod A

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Page 28: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

WW

X

Rod B

Rod A

Rod B

Rod A

φ40

-

56

-

φ50

φ50

61

64

φ50

φ71

64

77

φ71

φ80

77

80

φ80

φ100

80

82

φ100

φ100

82

94

φ100

φ140

94

102

φ125

-

97

-

φ140

-

102

-

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

Rod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

B

φ30 f9

φ34 f9

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ98 f9

φ108 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VD

10

10

9

9

8

8

6

5

5

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

Rod A

A

-

28

36

45

56

63

85

-

-

B

-

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ108 f9

-

-

MM

-

φ28

φ36

φ45

φ56

φ70

φ90

-

-

OF

-

φ26

φ34

φ43

φ54

φ68

φ88

-

-

S

-

22

30

38

50

60

80

-

-

SL

-

11

14

17

21

24

Drill hole

-

-

VD

-

9

9

8

8

6

5

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

Symbol

Bore

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

φ12 H9/f8

φ14 H9/f8

φ20 H9/f8

φ20 H9/f8

φ28 H9/f8

φ36 H9/f8

φ45 H9/f8

φ50 H9/f8

φ56 H9/f8

45

62

75

90

114

130

165

185

205

56

73

74

80

93

101

117

124

130

35

37

42

39

46

47

51

51

54

103

128

133

135

157

166

192

200

208

R17

R17

R28

R28

R33

R49

R52

R55

R58

32

40

60

60

80

100

120

130

140

25

25

25

32

31

35

35

35

32

147

172

191

200

229

257

289

300

308

164

189

219

228

262

306

341

355

366

16

20

30

30

40

50

60

65

70

+0.29

+0.30

+0.30

+0.30

+0.31

+0.32

+0.34

+0.34

+0.36

+0.69

+0.70

+0.70

+0.70

+0.91

+0.92

+0.94

+0.94

+0.96

12

18

17

16

18

18

24

25

24

19

19

33

33

41

56

62

65

68

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AE CB CD DE E EE FF FL

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

FP HC L MR PJ PM UB WF XC ZC

-

-

30

30

35

50

53

56

59

12

12

14

14

16

16

18

18

18

• Allowance of MM is f8.

Symbol

Bore

Symbol

Bore

52

With boots

Dimensional table

Page 29: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

TA160H-1 2 TA Bore B B Stroke - A B

● Positions of the cushion valves and air vents dependon the cylinder bore.

● Rod end thread length (A) must be longer when alock nut is attached to the rod end. Refer to "Rodend attachment/Rod end thread length with lock nut".

● If the stroke is short, pay attention to prevent thecushion valve from interfering with the mountingbracket.

● When you want to change the length of the projectedrod, specify the "WF".

● As for the dimensions not shown in these drawings,refer to the SD type (basic type).

● For the mounting of switches, refer to the dimen-sional drawings of "Switch set". All the contents otherthan “switch mounting dimensions” are identical.

Double-acting double rod (Rod B)

FF

AE

DE

XH+stroke

ZJ+stroke

XG

JR

ETD

UT

TL TLTC

OF

KK

VD

S

B

BB

A

SL

WF PLPJ+strokeFP

2-EE

MMD

A

C

B

OF

2-φ2

Drill holes in case of Rod dia. 90 mm. Port G thread type

Air vent

Air vent

Cushion valve8, max.

ZK+stroke

FPWF

XG

OFOF

KKKK

AWF+strokeFPA

MM

PK+stroke

MM

With boots

WW

WF

Set attachment

● Distance between the covers of the double rod type cylinder islonger than that of the single rod type cylinder by 10 mm.

53

Nylon tarpaulin f32·f40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - ff160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xf125 - f160 1/3.5 Stroke+X

● When the calculated WF has decimals, raise them to the next whole number.

WFRod B

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 - f80 1/4 Stroke+X

f100·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

Rod A

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Page 30: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

WW

X

Rod B

Rod A

Rod B

Rod A

φ40

-

56

-

φ50

φ50

61

64

φ50

φ71

64

77

φ71

φ80

77

80

φ80

φ100

80

82

φ100

φ100

82

94

φ100

φ140

94

102

φ125

-

97

-

φ140

-

102

-

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

Rod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

B

φ30 f9

φ34 f9

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ98 f9

φ108 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VD

10

10

9

9

8

8

6

5

5

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

Rod A

A

-

28

36

45

56

63

85

-

-

B

-

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ108 f9

-

-

MM

-

φ28

φ36

φ45

φ56

φ70

φ90

-

-

OF

-

φ26

φ34

φ43

φ54

φ68

φ88

-

-

S

-

22

30

38

50

60

80

-

-

SL

-

11

14

17

21

24

Drill hole

-

-

VD

-

9

9

8

8

6

5

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

Symbol

Bore

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

7

9

13

13

16

16

21

22

25

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

35

37

42

39

46

47

51

51

54

R2

R2

R2.5

R2.5

R3

R3

R4

R4

R4

56

73

74

80

93

101

117

124

130

66

83

84

90

103

111

127

134

140

45

62

75

90

114

130

165

185

205

12

18

18

17

20

20

29

28

29

φ16 f8

φ20 f8

φ25 f8

φ32 f8

φ40 f8

φ50 f8

φ63 f8

φ70 f8

φ80 f8

25

25

25

32

31

35

35

35

32

54

57

64

70

76

71

75

75

75

74

96

95

98

114

132

157

163

170

128

153

159

168

190

203

232

238

245

161

182

193

200

226

240

264

271

280

12

16

20

25

32

40

50

58

63

68

95

116

139

178

207

265

300

329

44

63

76

89

114

127

165

184

203

0

0

0

0

0

0

0

0

0

-0.62

-0.74

-0.74

-0.87

-0.87

-1.00

-1.00

-1.15

-1.15

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AE BB DE E EE FF FP JR PJ PK

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

PL TL UT WF XG XH ZJ ZKTC TD

12

12

14

14

16

16

18

18

18

• Allowance of MM is f8.

Symbol

Bore

Symbol

Bore

54

With boots

Dimensional table

Page 31: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

TC

WW

WF

Set attachment

160H-1 2 TC Bore B B Stroke - A B

● Positions of the cushion valves and air ventsdepend on the cylinder bore.

● Rod end thread length (A) must be longer whena lock nut is attached to the rod end. Refer to"Rod end attachment/Rod end thread lengthwith lock nut".

● If the stroke is short, pay attention to preventthe cushion valve from interfering with themounting bracket.

● The air vents on the rod side of the rod A typecylinder are located on the two sides neitherthe port nor the cushion valve is located.

● When you want to change the length of the pro-jected rod, specify the "WF".

● As for the dimensions not shown in these draw-ings, refer to the SD type (basic type).

● For the mounting of switches, refer to the di-mensional drawings of "Switch set". All the con-tents other than “switch mounting dimensions”are identical.

Double-acting double rod (Rod B)

FF

AE

DE

UW

BD

ZJ+stroke

XV+1/2 stroke=PH

JR

TD

UM

TL TLTM

KK

VD

S

B

BB

A

SL

WF PLPJ+strokeFP

2-EEE 8, max.

(Length of projected cushion valve)

HL+stroke

OFMMD

A

C

B

OF

2-φ12

Drill holes in case of Rod dia. 90 mm. Port G thread type

Air vent Air vent

Cushion valve

FPWF

XW+1/2 stroke=PH

KKKK

ZK+stroke

AWF+strokeFPA

MMOF

PK+stroke

OFMM

Bore

φ32

φ40

φ50

Stroke

10

10

10

Bore

φ63

φ80

φ100

Stroke

10

10

25

Bore

φ125

φ140

φ160

Stroke

25

25

35

Minimum stroke of TC type

● As for the minimum stroke of the switch set cylinder, refer to the modelcode.With boots

● Distance between the covers of the double rod type cylinder is longer thanthat of the single rod type cylinder by 10 mm.

55

Nylon tarpaulin f32·f40 1/3 Stroke+XChloroprene f50 1/3.5 Stroke+X

f63 - f100 1/4 Stroke+Xf125 - f160 1/5 Stroke+X

Conex f32 1/2 Stroke+Xf40·f50 1/2.5 Stroke+Xf63 - f100 1/3 Stroke+Xf125 - f160 1/3.5 Stroke+X

● When the calculated WF has decimals, raise them to the next whole number.

WFRod B

Nylon tarpaulin f40 1/3.5 Stroke+XChloroprene f50 - f80 1/4 Stroke+X

f100Å·f125 1/5 Stroke+X

Conex f40 1/2.5 Stroke+Xf50 - f80 1/3 Stroke+Xf100·f125 1/3.5 Stroke+X

Rod A

Notes) ● Remember that the resistible temperatures shown inthe table above are for the boots, not for the cylinder.

● Conex is the registered trademark of Teijin Ltd.● The boots have been mounted at our factory prior

to delivery.

ChloropreneResistible

temperature

Material

80°C

Nylon tarpaulin

Semi-standardStandard

200°C

Conex

130°C

Page 32: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

WW

X

Rod B

Rod A

Rod B

Rod A

φ40

-

56

-

φ50

φ50

61

64

φ50

φ71

64

77

φ71

φ80

77

80

φ80

φ100

80

82

φ100

φ100

82

94

φ100

φ140

94

102

φ125

-

97

-

φ140

-

102

-

φ32 φ40 φ50 φ63 φ80 φ100 φ125 φ140 φ160Symbol

Bore

Rod B

A

18

22

28

36

45

56

63

75

85

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

B

φ30 f9

φ34 f9

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ98 f9

φ108 f9

MM

φ18

φ22

φ28

φ36

φ45

φ56

φ70

φ80

φ90

OF

φ17

φ21

φ26

φ34

φ43

φ54

φ68

φ78

φ88

S

14

17

22

30

38

50

60

70

80

SL

10

9

11

14

17

21

24

27

Drill hole

VD

10

10

9

9

8

8

6

5

5

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

Rod A

A

-

28

36

45

56

63

85

-

-

B

-

φ42 f9

φ50 f9

φ60 f9

φ72 f9

φ88 f9

φ108 f9

-

-

MM

-

φ28

φ36

φ45

φ56

φ70

φ90

-

-

OF

-

φ26

φ34

φ43

φ54

φ68

φ88

-

-

S

-

22

30

38

50

60

80

-

-

SL

-

11

14

17

21

24

Drill hole

-

-

VD

-

9

9

8

8

6

5

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

Symbol

Bore

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

7

9

13

13

16

16

21

22

25

30

30

40

43

53

68

73

83

98

φ21.5

φ25.5

φ30

φ30

φ36.9

φ36.9

φ46.1

φ46.1

φ46.1

35

37

42

39

46

47

51

51

54

89

94

105

112.5

127.5

144

154.5

159.5

168

103

128

134

136

159

168

197

203

213

R2

R2

R2.5

R2.5

R3

R3

R4

R4

R4

56

73

74

80

93

101

117

124

130

66

83

84

90

103

111

127

134

140

45

62

75

90

114

130

165

185

205

12

18

18

17

20

20

29

28

29

φ16 f8

φ20 f8

φ25 f8

φ32 f8

φ40 f8

φ50 f8

φ63 f8

φ70 f8

φ80 f8

25

25

25

32

31

35

35

35

32

55

76

89

100

127

140

178

200

215

88

98.5

104

111

123.5

132.5

144.5

148

151

93

103.5

109

116

128.5

137.5

149.5

153

156

79

108

129

150

191

220

278

316

341

128

153

159

168

190

203

232

238

245

161

182

193

200

226

240

264

271

280

12

16

20

25

32

40

50

58

63

Rc1/4

Rc3/8

Rc1/2

Rc1/2

Rc3/4

Rc3/4

Rc1

Rc1

Rc1

G1/4

G3/8

G1/2

G1/2

G3/4

G3/4

G1

G1

G1

AE BB BD DE E EE FF FP HL JR MinimumPH

PJ

PK

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

PL TL TM UM UW WF XV XW ZJ ZKTD

55

76

89

100

127

140

178

200

215

0

0

0

0

0

0

0

0

0

-0.62

-0.74

-0.87

-0.87

-1.00

-1.00

-1.00

-1.00

-1.15

12

12

14

14

16

16

18

18

18

• Allowance of MM is f8.

Symbol

Bore

Symbol

Bore

56

With boots

Dimensional table

Page 33: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

Switch set

Minimum dimension PH of switch set cylinder 160H-1R

● The minimum dimension PH of the switch set cylinder is the dimensionwhen the trunnion is moved toward the rod side in case that the switchis mounted to the rod side.

160H-1R 2 SD Bore B B Stroke - A B Switch code Switch quantity

If the boots are equipped, the dimension WF is modified. Insuch a case, specify the dimension PH.

UXRY

RVRV37UX

Switch

Indicator lamp

PH

WF

57

Page 34: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

Dimensional table

Note) ● Figures on the previous page show the AX type switch (rear wiring). As for the AZ type switch (upper wiring), take intoconsideration the bending radius of cord.

● The dimension UX indicates the optimum switch mounting position at the detection of the stroke end.● Figures in the parentheses shown in the table above are applicable to the double rod type cylinder.

Working range and difference

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

4 - 14

11 - 18

5 - 15

11 - 20

3 - 8

6 - 13

4 - 10

1 or smaller2 or smaller

58

No contact

Working range Difference

AX1✽✽

Contact

Working range Difference

AX2✽✽Bore

mm

66

76

90

100

120

136

166

182

200

150 (155)

160 (165)

170 (175)

178.5 (183.5)

195.5 (200.5)

212 (217)

227.5 (232.5)

234.5 (239.5)

245 (250)

RY UX The minimum dimension PH

4 (9)

11 (16)

10 (15)

11 (16)

13 (18)

14 (19)

19 (24)

21 (26)

22 (27)

Bore

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

33

38

45

50

60

68

83

92

99

RVSymbol

Page 35: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

Rod end attachment

● Rod end eye (T-end)

ER

KK

Set screw

RA

ED

CE

LE

EM EF

CK AV

● Rod end clevis (Y-end)

BL

CV

KK

ED

ER

RA

CELE

CL

CW

CM

CW

CK AV

Set screw

KK

Keeper plateKeeper plate

Hexagonal head boltf32 · f40 Bolt w/hexagonal hole

f50 · f63 Hexagonal head bolt

CR

ER

CE

J

LE

ED

RA

CK AV

45°

BL CL CM

CW

CV

CW

Set screw

● Delivery of rod end attachment (T-end, Y-end) Set screw is not attached.Only tapping is done.

Rod end attachment

Rod end attachment

Drilled

Set screw (full dog point)

Piston rod

Piston rod

Lock nut

(1) In the case that the lock nut and rod end attachment areadditionally orderedThe rod end attachment and lock nut are temporarily as-sembled to the piston rod for delivery. Since the lock nut isnot tightened, tighten it after the position of the rod end at-tachment is adjusted. No set screw is included.

(2) In the case that only the rod end attachment is additionallyordered (without lock nut)The rod end attachment is tightened to the piston rod, and adrill hole is made on the piston rod for delivery.

If a drill hole is unnecessary, advise us.

Bore from 32 mm to 63 mm Bore from 80 mm to 160 mm

59

Page 36: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

Dimensional table/rod end eye (T-end)

Dimensional table/rod end clevis (Y-end)

Rod B

Part code

RTH-14-H

RTH-16-3-H

RTH-20-3-H

RTH-27-H

RTH-33-H

RTH-42-H

RTH-48-3-H

RTH-56-1-H

RTH-64-4-H

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

AV

21

25

31

39

48

59

66

78

88

CE

50

55

67

78

94

112

125

148

158

RA

67

72

96

107

128

162

178

204

217

Set screw

M6

M6

M6

M6

M6

M8

M10

M12

M12

Set screw

-

M6

M6

M6

M8

M10

M12

-

-

Part code

-

RTH-20-4-H

RTH-27-H

RTH-33-1-H

RTH-42-1-H

RTH-48-4-H

RTH-64-5-H

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

AV

-

31

39

48

59

66

88

-

-

CE

-

67

78

94

112

135

158

-

-

RA

-

84

107

123

146

185

211

-

-

Rod A

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

16

20

30

30

40

50

60

65

70

0

0

0

0

0

0

0

0

0

-0.27

-0.33

-0.33

-0.33

-0.39

-0.39

-0.46

-0.46

-0.46

EMCK ED ER LE

φ12 H9

φ14 H9

φ20 H9

φ20 H9

φ28 H9

φ36 H9

φ45 H9

φ50 H9

φ56 H9

34

34

58

58

68

100

106

112

118

EF

25

30

40

40

50

65

75

85

100

EF

-

35

40

50

65

75

100

-

-

R17

R17

R29

R29

R34

R50

R53

R56

R59

19

19

32

32

39

54

57

63

63

Symbol

Bore

Symbol

Bore

Rod B

Part code

RYH-14-H

RYH-16-3-H

RYH-20-3-H

RYH-27-H

RYH-33-H

RYH-42-H

RYH-48-3-H

RYH-56-1-H

RYH-64-4-H

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

AV

21

25

31

39

48

58

68

85

95

CE

50

55

67

78

94

112

125

148

158

RA

67

72

96

107

125

155

170

198

212

Part code

-

RYH-20-4-H

RYH-27-H

RYH-33-1-H

RYH-42-1-H

RYH-48-4-H

RYH-64-5-H

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

AV

-

31

39

48

59

66

90

-

-

CE

-

67

78

94

112

135

158

-

-

RA

-

84

107

123

143

178

203

-

-

Rod A

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

CK CM ED ER LE

φ12 H9/f8

φ14 H9/f8

φ20 H9/f8

φ20 H9/f8

φ28 H9/f8

φ36 H9/f8

φ45 H9/f8

φ50 H9/f8

φ56 H9/f8

34

34

58

58

65

90

100

100

110

R17

R17

R29

R29

R33

R48

R51

R55

R59

19

19

32

32

39

54

57

63

63

CWCL CVBL

8

10

15

15

20

25

30

32.5

35

32

40

60

60

80

100

120

130

140

8

8

10

10

10

13

14

18

18

CR

-

-

-

-

31

43

45

50

54

J

-

-

-

-

22

24

28

28

33

42

50

72

72

92

115

138

152

162

16

20

30

30

40

50

60

65

70

+0.29

+0.30

+0.30

+0.30

+0.31

+0.32

+0.34

+0.34

+0.36

+0.69

+0.70

+0.70

+0.70

+0.91

+0.92

+0.94

+0.94

+0.96

Set screw

M6

M6

M6

M6

M6

M8

M10

M12

M12

Set screw

-

M6

M6

M6

M8

M10

M12

-

-

Symbol

Bore

Symbol

Bore

60

Page 37: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

● Parallel pin

H B

C

d

Lock nutRod end attachment

A

The standard fitting length of the rod end attachment and piston rod isapproximately 80% of the thread diameter. When using a lock nut, it isrequired to lengthen the thread length (A) as shown in the figure above.If you order a cylinder with lock nut attached (symbol: K), the threadlength (A) is as shown in the table on the next page.

● Keeper plate

● Lock nut

● Thread length with lock nut

BL

DC

CK

E

F

G

K

2-L

J

N

H

I

61

Page 38: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinderUnit: mm

Note) ● For the rod A type, the bore is within the range from 40 mm to 125 mm.

Note) ● For the rod A type, the bore is within the range from 40 mm to 125 mm.

Dimensional table/Parallel pin

Rod A, B

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

BL

42

50

72

72

92

115

138

152

162

C

4

4

5.5

5.5

5.5

7

7

10

10

CK

φ12f8

φ14f8

φ20f8

φ20f8

φ28f8

φ36f8

φ45f8

φ50f8

φ56f8

D

4

4

4.5

4.5

4.5

6

7

8

8

E

2

2

3

3

4

5

5.5

7

7

Symbol

Bore

Dimensional table/Keeper plateRod A, B Mounting

bolt

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

F

19

19

32

32

38

44

60

65

65

G

10

10

17

17

23

24

32

41

41

H

5.5

5.5

8

8

7

11

15

15

15

I

4.5

4.5

8

8

8

11

13

15

15

J

10

10

16

16

15

22

28

30

30

K

3

3

4.5

4.5

4.5

6

6

9

9

L

φ5.5

φ5.5

φ6.6

φ6.6

φ6.6

φ9

φ11

φ13

φ13

N

C2.5

C2.5

C4

C4

C4

C3

C10

C10

C10

M5

M5

M6

M6

M6

M8

M10

M12

M12

Symbol

Bore

Rod B

Parts model

LNH-14F-H

LNH-16F-1-H

LNH-20F-2-H

LNH-27F-H

LNH-33F-H

LNH-42F-1-H

LNH-48F-2-H

LNH-56F-1-H

LNH-64F-2-H

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

d

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

B

22

24

30

41

50

65

75

85

95

C

25.4

27.7

34.6

47.3

57.7

75

86.5

98.1

110

H

11

13

16

22

26

34

38

45

51

Parts model

-

LNH-20F-2-H

LNH-27F-H

LNH-33F-H

LNH-42F-1-H

LNH-48F-2-H

LNH-64F-2-H

-

-

d

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

B

-

30

41

50

65

75

95

-

-

C

-

34.6

47.3

57.7

75

86.5

110

-

-

H

-

16

22

26

34

38

51

-

-

Rod ASymbol

Bore

Dimensional table/Lock nut

Dimensional table/A when lock nut is used (long thread)

Rod B

φ32

φ40

φ50

φ63

φ80

φ100

φ125

φ140

φ160

KK

M14×1.5

M16×1.5

M20×1.5

M27×2

M33×2

M42×2

M48×2

M56×2

M64×3

A

28

32

40

54

66

84

96

112

128

A

-

40

54

66

84

96

128

-

-

KK

-

M20×1.5

M27×2

M33×2

M42×2

M48×2

M64×3

-

-

Rod ASymbol

Bore

62

Page 39: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-1 16 MPa double-acting type hydraulic cylinder Unit: mm

The basic dimension table (=160H-1Standard dimension)

The basic dimension table

■ Slight dimension change on the basis of 160H-1 series standard thread size.

■ A01’s basic dimension shows the original 160H-1’s standard itself. Don’t use semi-standard symbols to avoid confusion in such a case.

■ In case of over sized thread, the symbol should be ‘A00’ , not ‘A01’.

■ In case of ordering over sized thread ■ In case of applying the standard thread size of

70/140H-8 series

■ On this symbol ‘A00’ the basic dimension is completely different from that of ‘A01’. ‘A00’s basic is originally based on the standard of 70/140H-8.

• bore:40mm, rod:B, thread size:M16×2, WF:80mm (order)160H-1 1CA40BB250-AB-X A01

KM-16, KP-2, WF-80(manufacturing) rod end style A=22, KM=16, KP=2,

WF=80, fMM=f22, fOF=f21, R=1.6, S=17• bore:100mm, rod:B, thread size:M45×1.5

‘A01’ can’t be used. Refer to the symbol ‘A00’.

• bore:63mm, rod:B, ‘A00’ basic dimensions (order)160H-1R 2FA63BB300-BC-X A00(manufacturing) rod end style A=45, KM=30,

KP=1.5, W=48, fMM=f36, R=1.6, S=30

• bore:100mm, rod=B, thread size M45×1.5 other dimensions from ‘A01’ basic (order)160H-1 2CB100BR500-AB-X A00

KM-45, KP-1.5, A-56(manufacturing) rod end style A=56, KM=45,

KP=1.5, WF=35, fMM=f56, R=1.6, S=50

• bore:50mm, rod:B, thread size:M22×1.5, WF:100mm, other dimensions from the basic(order)160H-1 2CA50BB500-AB-X A00 KM-22, KP-1.5, WF-100(manufacturing) rod end style A=35, KM=22,

KP=1.5, WF=100, fMM=f28, R=1, S=24

Occasion

ex.

Note

Occasion

ex.

Note

f32

f40

f50

f63

f80

f100

f125

f140

f160

Bore

18

22

28

36

45

56

63

75

85

14

16

20

27

33

42

48

56

64

1.5

1.5

1.5

2

2

2

2

2

3

f18

f22

f28

f36

f45

f56

f70

f80

f90

f17

f21

f26

f34

f43

f54

f68

f78

f88

1

1.6

1.6

2

2

2

2

2

3

14

17

22

30

38

50

60

70

Drill hole

35

35

41

48

51

57

57

58

57

25

25

25

32

31

35

35

35

32

A KM KP ✽ MM ✽ OF ✽ R ✽ SW

(FA type)

WF

(Others)

f32

f40

f50

f63

f80

f100

f125

f140

f160

Bore

25

30

35

45

60

75

95

110

120

16

20

24

30

39

48

64

72

80

1.5

1.5

1.5

1.5

1.5

1.5

2

2

2

f18

f22

f28

f36

f45

f56

f70

f80

f90

1

1

1

1.6

1.6

1.6

2

2

2

14

19

24

30

41

50

65

75

85

35

35

41

48

51

57

57

58

57

25

25

25

32

31

35

35

35

32

A KM KP ✽ MM ✽ R ✽ S

Within the basic thread sizeOver the basic thread size, it goes for ‘A00’

Parameter KM and KP need to be specified as a pair.

Semi-standard symbols:

Optional parameters:

A01

A W WFKM KP

Parameter KM and KP need to be specified as a pair.

Semi-standard symbols:

Optional parameters:

A00

A W WFKM KP

• Dimensions indicated by ✽ Mark are fixed as our semi-standard. • You are requested to consult us if you would like to change fixed dimensions.

W

(FA type)

WF

(Others)

✽ fOF

✽ RWidth across flats ✽ S

KM×KP

Flat E

3

15˚

A

✽ fMM

3

15˚

✽ fMM

W,WF

✽ R

Width across flats ✽ SA W,WF

Symbol A00

over sized thread

the basic size thread

A 0 1

KM×KP

Special specification at the rod end For rod size B (Please cosult us in case of ‘A rod’ or the case that doesn’t go for ‘A01’ or ‘A00’ below.)

How to order

• You can easily order following categolized items using the Semi-standard symbols and dimensional parameters. (No need to specify dimensional parameters if you would apply the basic dimensions.) Series Model number – X Semi-standard symbols Dimensional parameters

63

Page 40: 160H-1 · 2014. 2. 17. · 160H-1 16 MPa double-acting type hydraulic cylinder 16 MPa double-acting hydraulic cylinder with size conforming to JIS standards Standard specifications

160H-116 MPa double-acting type hydraulic cylinder

Specified tie rod tightening torque table.(Note:Molybdenous Grease should be used.)

1. Loosen the two set screws with an Allen wrench, andmove them along with the tie rod.

2. Adjust the detecting position (for the 2-lamp type,the position that the green lamp lights up) 2 to 5 mm

(about half of the working range is appropriate) be-fore the required position that the switch indicatorlamp starts to light up (ON). Then, gently hold thetop of the switch so that the cylinder tube contactsthe detecting face of the switch, and clamp the set

screw with the appropriate clamp torque.Note) Inappropriate clamp torque may cause the off-

center of the switch position.3. The indicator lamp lights up when the switch is set to

the ON position.

4. Switches can be mounted to any of four tie rods andon the most suitable position depending on themounting space of the cylinder and wiring method.

5. Mount a switch to the most suitable position todetect the stroke end with the “Switch mounting

dimension” (dimension UX).

Setting method of switch detecting position

Adjust until the switch comes in contact with the cylinder tube.

Hold with hands.

Tie rod size (M6 and M8) : M5 set screw (clamp torque 1 to 2 N • m

Tie rod size (M12 to M27) : M6 set screw (clamp torque 2 to 3 N • m

Tie rod

M4 switch mounting screw [clamp torque 0.6 to 1 N • m]

AX Type

Fit the attachment into the middle position of the switch.Fit from the direction shown in the left figure for easier fitting.

Fix to the bracket with the M4 switch mounting screw.

Take into consideration the points shown below.We cannot be responsible for faults due to inappropri-

ate installation of the cylinder.(1) Fixed typeSD type● Thread precision of tie rod: JIS 6g● Tightening torque: Specified tie rod tightening torque

Bore (mm)

Tie rod thread

Tightening torque N• m

φ32

M6×1

8

φ40

M8×1

22

φ50 • 63

M12×1.25

70

φ80 • 100

M16×1.5

170

Bore (mm)

Tie rod thread

Tightening torque N• m

φ125

M22×1.5

460

φ140

M24×1.5

610

φ160

M27×2

850

Installation of cylinder

63 64