2-3 - skyedge vsats

23
1 SkyEdge VSATs

Upload: api-3775524

Post on 10-Apr-2015

2.431 views

Category:

Documents


11 download

TRANSCRIPT

Page 1: 2-3 - SkyEdge VSATS

1

SkyEdge VSATs

Page 2: 2-3 - SkyEdge VSATS

2

SkyEdge VSATs Overview

Supporting different markets and applications over one Hub

Improving operators’ business plan

No price performance compromises - choosing the cost

effective VSAT for the applicable market

SkyEdge VSAT family:

SkyEdge Pro – Multi service

SkyEdge IP – IP router

SkyEdge Call – Telephony

SkyEdge Gateway – Trunking solutions

SkyEdge DVB-RCS – Enhanced standard

SkyEdge Armadillo – Hardened VSAT

Cisco Network Module – Powered by SkyEdge

Page 3: 2-3 - SkyEdge VSATS

3

High-end multi purpose two- way VSAT

Supports a wide variety of markets and applications

Full IP support for any standard IP application

Full telephony capabilities - both VoIP & native voice

Legacy protocol support

19” rack mount option

SkyEdge Pro Multi service VSAT

LAN

ATM/POS/

Lottery

Serial

VideoConference Cash Register

Serial

Phone FaxPublic Phone

SkyEdge Pro

Page 4: 2-3 - SkyEdge VSATS

4

SkyEdge Pro Multi service VSAT – cont.

Field upgradeable plug-in cards

FXS – 1, 2, 4 lines per card (Up to 12 lines per VSAT)

Serial – dual serial-port card with two mini-DB25 connectors

Quad LAN – 100BaseT

Mesh – supporting mesh and multi star

LCD and keypad navigator VSAT interface

High-end power supply

AC 110/220V

DC 12V

LAN

ATM/POS/

Lottery

Serial

VideoConference Cash Register

Serial

PSTN

SkyEdge Pro

Page 5: 2-3 - SkyEdge VSATS

5

SkyEdge ProID Card

Network Topology:Antenna Size:

Frequency:

Star, Mesh, Multi-star0.55m to 1.2m (Ku), 1.8m (C)Ku, C, Ex. C

Min Symbol Rate:Maximum Bit Rate:

Access Method:Mod. & Coding:

FEC:

256ksps1

66 Mbps3

DVB-SQPSK Viterbi & RS, QPSK or 8PSK Turbo coding2

1/2, 2/3, ¾, 5/6, 7/8, 8/93

Symbol Rates:Bit Rates:

Channel Spacing:Mod. and Coding:Access Scheme:

38.4ksps – 1232 ksps60kbps - 2Mbps 88 – 2094 KHzGMSK Turbo Coding (FEC ~3/4, ~7/8)Combined FDMA, TDMA

Standard Ports:Other Protocols:Expansion Slots:

GeneralSpecifications

OutboundChannel

InboundChannel

User Ports

Other Features

1 x 100BaseT LAN, 1 x Async RS232 DB92 Serial 3 (Mesh, 4Port LAN, Serial, 1-4 ports FXS)

Supported IP:

Acceleration:QoS:

Operating Voltage:

DHCP, NAT, RIP v1/v2, IRDP, IGMP, ACL, NAT, SNMP, IGMP, VLAN Tagging

TCP (Embedded), HTTP (embedded), VPN (embedded)

IB: BWS, MPN, Diffserv / OB: Allot

Wide range 72-250VAC or 12VDC (11V-15V)

(1) DVB, FEC ¾(2) Optional(3) 8PSK only

Page 6: 2-3 - SkyEdge VSATS

6

SkyEdge IP IP Router VSAT

Stand alone VSAT implementing embedded TCP and HTTP

acceleration software

High inbound bit rate up to 2Mbps

Onboard 100BaseT port

On board serial port – Async applications support

Full IP support for any standard IP application

Embedded VPN

Residential GatewayPhone

IDU

LAN

ATM/POS/

Lottery

Serial

Modem

Internet/Intranet

VideoConference

Page 7: 2-3 - SkyEdge VSATS

7

SkyEdge IPID Card

Network Topology:Antenna Size:

Frequency:

Star0.55m to 1.2m (Ku), 1.8m (C)Ku, C, Ex. C

Min Symbol Rate:Maximum Bit Rate:

Access Method:Mod. & Coding:

FEC:

256ksps1

66 Mbps3

DVB-SQPSK Viterbi & RS, QPSK or 8PSK Turbo coding2

1/2, 2/3, ¾, 5/6, 7/8, 8/93

Symbol RatesBit Rates:

Channel SpacingMod. and CodingAccess Scheme:

38.4ksps – 1232 ksps60kbps - 2Mbps 88 – 2094 KHzGMSK Turbo Coding (FEC ~3/4, ~7/8)Combined FDMA, TDMA

Standard Ports:Other Protocols:Expansion Slots:

GeneralSpecifications

OutboundChannel

InboundChannel

User Ports

Other Features

1 x 100BaseT LAN, 1 x Async RS232 DB92

NoneNone

Supported IP:

Acceleration:QoS:

Operating Voltage:

DHCP, NAT, RIP v1/v2, IRDP, IGMP, ACL, NAT, SNMP, IGMP, VLAN Tagging

TCP (Embedded), HTTP (embedded), VPN (embedded)

IB: BWS, MPN, Diffserv / OB: Allot

Wide range 100-240VAC or 12VDC (11V-15V)

(1) DVB, FEC ¾(2) Optional(3) 8PSK only

Page 8: 2-3 - SkyEdge VSATS

8

SkyEdge Call Telephony VSAT

Low cost rural telephony VSAT

1 or 2 voice port support

Voice, Fax and in band data support

Power conservation modes

AC/DC Versions

Prepaid (optional) and payphone support

Best tailored for

Universal Service Obligation (USO) projects

Thin route telephony needs at remote locations

Standalone emergency phone

Solar implementation

Prepaid

Payphone

PIN CODE

41766488963PIN CODE

41766488963PIN CODE

41766488963

SolarPower

SkyEdge Call

SkyEdge Call

Page 9: 2-3 - SkyEdge VSATS

9

SkyEdge CallID Card

Network Topology:Antenna Size:

Frequency:

Star0.55m to 1.2m (Ku), 1.8m (C)Ku, C, Ex. C

Min Symbol Rate:Maximum Bit Rate:

Access Method:Mod. & Coding:

FEC:

256ksps1

66 Mbps3

DVB-SQPSK Viterbi & RS, QPSK or 8PSK Turbo coding2

1/2, 2/3, ¾, 5/6, 7/8, 8/93

Symbol Rates:Bit Rates:

Channel Spacing:Mod. and Coding:Access Scheme:

38.4ksps – 1232 ksps60kbps - 2Mbps 88 – 2094 KHzGMSK Turbo Coding (FEC ~3/4, ~7/8)Combined FDMA, TDMA

Standard Ports:Other Protocols:Expansion Slots:

GeneralSpecifications

OutboundChannel

InboundChannel

User Ports

Other Features

1 or 2 FXS NoneNone

PSM:Multi-star

Operating Voltage:

Power Save mode for Solar implementation

1.5 hops connection with mesh VSATs

Wide range 100-240VAC or 12VDC (11V-15V)

(1) DVB, FEC ¾(2) Optional(3) 8PSK only

Page 10: 2-3 - SkyEdge VSATS

10

SkyEdge Gateway Gateway VSAT

Multiple connections to the PSTN

Supports full E1 per IDU

Supports Mesh card

Inherent IP support

SS7(*) & MFCR2 support

Onboard optional serial port for Async applications

19’ enclosure

Cascading IDUs for increased capacity

Linear Block Up Converter (BUC) from L-band level

Requires an additional L-band combiner/splitter box

Can be connected with PABXs for large number of interfaces

Communicates with:

Star VSATs in 1.5 hops

Mesh VSATs in single hop

Page 11: 2-3 - SkyEdge VSATS

11

SkyEdge Gateway Gateway VSAT – cont.

Mesh IP on demand

Up to 1.3Mbps, no need for external modem

Routes the data to a predefined destination based

on the IP address

Use dynamic bit rate per session to predefined address (*)

Low-end & high-end telephony VSATs interoperability

SkyEdge Call, SkyEdge Pro and SkyEdge Gateway can be

connected to the same network

Page 12: 2-3 - SkyEdge VSATS

12

SkyEdge GatewayID Card

Network Topology:Antenna Size:

Frequency:

Star, Mesh, Multi-star0.55m to 1.2m (Ku), 1.8m (C)Ku, C, Ex. C

Min Symbol Rate:Maximum Bit Rate:

Access Method:Mod. & Coding:

FEC:

256ksps1

66 Mbps3

DVB-SQPSK Viterbi & RS, QPSK or 8PSK Turbo coding2

1/2, 2/3, ¾, 5/6, 7/8, 8/93

Symbol Rates:Bit Rates:

Channel Spacing:Mod. and Coding:Access Scheme:

38.4ksps – 1232 ksps60kbps - 2Mbps 88 – 2094 KHzGMSK Turbo Coding (FEC ~3/4, ~7/8)Combined FDMA, TDMA

Standard Ports:Other Protocols:Expansion Slots:

GeneralSpecifications

OutboundChannel

InboundChannel

User Ports

Other Features

1 x 100BaseT LAN, 1 x Async RS232 DB92 Serial3 (Mesh, 4Port LAN, Serial, 1-4 ports FXS, E1)

Supported IP:

Acceleration:Signaling:

Operating Voltage:

DHCP, NAT, RIP v1/v2, IRDP, IGMP, ACL, NAT, SNMP, IGMP, VLAN Tagging

TCP (Embedded), HTTP (embedded), VPN (embedded)

MFCR2, SS#7 (associated mode requires external IP mux)

Wide range 72-250VAC or -48VDC (40V-60V)

(1) DVB, FEC ¾(2) Optional(3) 8PSK only

Page 13: 2-3 - SkyEdge VSATS

13

SkyEdge DVB-RCS VSAT

Satlabs approved RCS VSAT

Dual mode VSAT

Linear IDU and ODU support

Can operate with SkyEdge proprietary return channel

Full IP set capability, similar to SkyEdge IP

Quality-of-Service (QoS)

Protocol acceleration (HTTP and TCP)

Accelerated VPN

Encryption and compression

Etc.

Page 14: 2-3 - SkyEdge VSATS

14

SkyEdge DVB-RCSID Card

Network Topology:Antenna Size:

Frequency:

Star0.55m to 1.2m (Ku), 1.8m (C)Ku, C, Ex. C

Min Symbol Rate:Maximum Bit Rate:

Access Method:Mod. & Coding:

FEC:

256ksps1

66 Mbps3

DVB-SQPSK Viterbi & RS, QPSK or 8PSK Turbo coding2

1/2, 2/3, ¾, 5/6, 7/8, 8/93

Symbol RatesBit Rates:

Channel SpacingMod. and CodingAccess Scheme:

38.4ksps – 1232 ksps60kbps - 2Mbps 88 – 2094 KHzGMSK Turbo Coding (FEC ~3/4, ~7/8), QPSK (1/2, 2/3, ¾, 4/5, 6/7)Combined FDMA, TDMA, or RCS

Standard Ports:Other Protocols:Expansion Slots:

GeneralSpecifications

OutboundChannel

InboundChannel

User Ports

Other Features

1 x 100BaseT LAN, 1 x Async RS232 DB92 NoneNone

Supported IP:

Acceleration:QoS:

Operating Voltage:

DHCP, NAT, RIP v1/v2, IRDP, IGMP, ACL, NAT, SNMP, IGMP, VLAN Tagging

TCP (Embedded), HTTP (embedded), VPN (embedded)

IB: BWS, MPN, Diffserv / OB: Allot

Wide range 100-240VAC or 12VDC (11V-15V)

(1) DVB, FEC ¾(2) Optional(3) 8PSK only

Page 15: 2-3 - SkyEdge VSATS

15

SkyEdge Armadillo Hardened VSAT

SkyEdge VSAT unit encased in industrial strength

metal

Suitable for extreme weather conditions

Easy mounting requirements

Low power requirements

Suitable for –400C to +600C

AC or DC

Lightning protection

Residential GatewayPhone

IDU

LAN

ATM/POS/

Lottery

Serial

Modem

Internet/Intranet

VideoConference

Page 16: 2-3 - SkyEdge VSATS

16

SkyEdge Armadillo ID Card

Network Topology:Antenna Size:

Frequency:

Star0.55m to 1.2m (Ku), 1.8m (C)Ku, C, Ex. C

Min Symbol Rate:Maximum Bit Rate:

Access Method:Mod. & Coding:

FEC:

256ksps1

66 Mbps3

DVB-SQPSK Viterbi & RS, QPSK or 8PSK Turbo coding2

1/2, 2/3, ¾, 5/6, 7/8, 8/93

Symbol RatesBit Rates:

Channel SpacingMod. and CodingAccess Scheme:

38.4.4ksps – 1232 ksps60kbps - 2Mbps 88 – 2094 KHzGMSK Turbo Coding (FEC ~3/4, ~7/8)Combined FDMA, TDMA

Standard Ports:Other Protocols:Expansion Slots:

GeneralSpecifications

OutboundChannel

InboundChannel

User Ports

Other Features

1 x 100BaseT LAN, 1 x Async RS232 DB92

NoneNone

Supported IP:

Acceleration:QoS:

Operating Voltage:Operating Temp

DHCP, NAT, RIP v1/v2, IRDP, IGMP, ACL, NAT, SNMP, IGMP, VLAN TaggingTCP (Embedded), HTTP (embedded), VPN (embedded)IB: BWS, MPN, Diffserv / OB: Allot Wide range 100-240VAC or 12VDC (11V-15V)-40 C to + 60C, 100% humidity

(1) DVB, FEC ¾(2) Optional(3) 8PSK only

Page 17: 2-3 - SkyEdge VSATS

17

Cisco NM SkyEdge Compatible

A two-way VSAT Network Module that plugs-into Cisco routers

Motivation & Synergies

Content distribution and business video

Backup to terrestrial WAN

Primary WAN services to remote offices,

WiFi Hot Spots, temporary sites

VSAT plug-in card to medium-high end Branch Office routers

Service by SkyEdge hub operators worldwide

Outdoor “Sat Kit” and Antenna are required for module operation and

provided by the hub operators

Page 18: 2-3 - SkyEdge VSATS

18

Cisco NMID Card

Network Topology:Antenna Size:

Frequency:

Star0.55m to 1.2m (Ku), 1.8m (C)Ku, C, Ex. C

Min Symbol Rate:Maximum Bit Rate:

Access Method:Mod. & Coding:

FEC:

256ksps1

66 Mbps3

DVB-SQPSK Viterbi & RS, QPSK or 8PSK Turbo coding2

1/2, 2/3, ¾, 5/6, 7/8, 8/93

Symbol RatesBit Rates:

Channel SpacingMod. and CodingAccess Scheme:

38.4ksps – 1232 ksps60kbps - 2Mbps 88 – 2094 KHzGMSK Turbo Coding (FEC ~3/4, ~7/8)Combined FDMA, TDMA

Standard Ports:Other Protocols:Expansion Slots:

GeneralSpecifications

OutboundChannel

InboundChannel

User Ports

Other Features

None (Ethernet over PCI Internal to router) NoneNone

Supported IP:

Acceleration:QoS:

Operating Voltage:

DHCP, NAT, RIP v1/v2, IRDP, IGMP, ACL, NAT, SNMP, IGMP, VLAN Tagging

TCP (Embedded), HTTP (embedded), VPN

IB: BWS, MPN, Diffserv / OB: Allot

External PS 110V or 220V (part of SkyKit)

(1) DVB, FEC ¾(2) Optional(3) 8PSK only

Page 19: 2-3 - SkyEdge VSATS

19

SkyEdge VSATsEnclosure

6 LCD panel LEDs

LCD & keypad navigator interface

Configuration, Testing, VSAT Status, Telephony features

Support for installers when using the high- products (SkyEdge Pro, SkyEdge Gateway)

Indication LEDS:

Power - Power is on

Rx_lock - DVB (outbound) receiver is locked

SYNC_lock - The VSAT is synchronized with the Hub timing

On_line – VSAT-HUB connection established

Transmit (inbound) - Transmit data to the HUB

VPN (security engine) activity LED (exist only in Phase II enclosure)

Ethernet indication LEDS:

Green – Good link indication, Yellow – Data transmit indication

Page 20: 2-3 - SkyEdge VSATS

20

Web based VSAT portal used for monitoring & control

VSAT configuration

VSAT monitoring (Real time graphs, VSAT status)

Antenna self pointing

Test commands

VSAT web server supports:

PC based browsers

Palm (Blazer Web browser)

iPAQ (IE for Pocket PC)

Available in Version 4.0

“SkyManage” can not be reached from the NMS

SkyEdge VSATsSkyManage

Page 21: 2-3 - SkyEdge VSATS

21

RFODU & LNB

Frequency Range: Receive Transmit

Ku-Band: 10.95 - 11.70 GHz 14.00 - 14.50 GHz

11.70 - 12.20 GHz 13.75 - 14.25 GHz

12.20 - 12.75 GHz

C-Band: 3.62 - 4.20 GHz 5.850 - 6.425 GHz

Ex. C-Band: 4.50 - 4.80 GHz 7.625 - 7.925 GHz

Ka-Band 19.7 - 20.2 GHz 29.50 - 30 GHz

ODU:

Ku-Band: 1W, 2W, 4W (3W linear)

C-Band: 2W, 5W

Ex. C-Band: 2W

Ka -Band 1W

LNB: standard TVRO based

RF Input/Output: F type connectors, 75 Ω female

Page 22: 2-3 - SkyEdge VSATS

22

SkyEdge VSATsExpansion Cards

FXS Voice:

1, 2, 4 FXS ports RJ-11

Mesh

Up to 1.3Mbps (GMSK, TC)

Mandates PLL LNB (Pro,

Gateway)

Mesh kit (L-band splitter)

Serial Card (Sync/Async)

RS232/RS422 support

1 DB25 Pin-out

X.25 over TCP (XOT, RFC 1613 )

Serial Asynchronous

2 DB9F pin-out

Maximum rate 128kbps

Up to 6 ports per VSAT

4Port LAN Switch

Four 10/100BaseT LAN, RJ45

E1

RJ45 (BNC120), BNC 75

G.703, full E1 support (30 calls)

Inherent MFCR2 signaling

Embedded serial Interface:

9-pin interface used to interface with

asynchronous applications (RS232) in

DCE mode

Standard DB9F connector employed

Page 23: 2-3 - SkyEdge VSATS

23