2014 prostar high frequency online ups (single phase)
DESCRIPTION
Rack-mount online UPS can be mounted in standard 19" rack enclosures and can require anywhere from 1U to 12U (rack space). They are typically used in server and networking applications. Prostar rack mount ups is designed to protect office servers, PCs, graphic workstations, and commercial electronics. The Intelligent LCD diagnostic panel gives administrators immediate, real-time information about vital UPS performance factors. LCD diagnostics include Input/Output Voltage, Battery Capacity, Estimated Runtime, Load Level, On Battery, Overload, and Silent Mode.TRANSCRIPT
Prostar High Frequency UPS
Monitoring Software
USB Port
RS232 Port
ECO Mode
Generator Support
SNMP Module
High Power Factor
EPO Mode
Venus Series (1kVA -10kVA) 1:1Mercury Series (1kVA -10kVA) 1:1
UninterruptiblePowerSupply
Load Info
Mode Operation Info
Mute Operation
Battery Info
Output & BatteryVoltage Info
RemainingBackup Time Info
Fault Info
Output & BatteryVoltage Info
1
2
3
4
5
6
7
8
True double-conversion online UPS
Compared to the online UPS in the current market, Venus series
UPS provides better output power factor up to 0.8. It offers higher
performance and effciency for critical applications.
Output power factor 0.8
Venus series can still provide stable power to connected devices
under unstable power environments.
Wide input voltage range (110V-300V)
Lock output frequency at 50Hz or 60Hz to suit power sensitive
equipments.
50/60 Hz Frequency Converter Mode
Offers efficiency as high as 97% to cut energy usage &cost.
UPS power application via static bypass, timely returning to
online double conversion when the need arises.
ECO mode operation for energy saving
This feature can secure the personnel and equipment in case of
fires or other emergencies.
Emergency Power Off (EPO) Function
This feature allows either USB,RS232 or Rj45 communication
port to work with SNMP interface simultaneously.
A DSP controller provides an improved and cost-effective solution
with high performance.
DSP technology applied for 6-10K models
A true double conversion UPS will provide clean, high level quality
power to fully protect mission-critical devices such as sensitive
networks, small computer centers, servers, telecom applications,
as well as for industrial applications.
Venus SeriesHigh Frequency Online UPS
Function Features
USB and Rs232 communication Ports
Intelligent cooling fan
Circuit Breaker
AC Input
Internal Slot
Network/Fax/ModemSurge Protection
External Batery Connection
Output terminal
www.Prostar-cn.com
Monitoring software
SNMP Card AS-400 Card
Accessory
UPS can be connected to the computer via USB or Rs232 interface. So it can be realized LAN monitoring single or many sets of UPS, it also can monitor the other ups which connected to the computer via LAN.
UPS monitoring software has more than 10 kinds of language for choice.
Humanized operation interface, which is powerful and can shows the battery voltage, frequency, load, temperature and other data by real-time monitoring through the charts.
Alarm of different power incident could be set by radio, mobile phone text messages, e-mails and SNMP etc.
Historical data log could be recorded and stored in the computer database, and it could make the events statistics and analysis in the form of chart.
ISO9001ISO14001
IQNet
CE RoHS
Rear Panel View
LCD Display
Monitoring Software
USB Port
RS232 Port
Network/Fax/Modem Port
2 x Outlets
SNMP Module(Option)
AS-400 CardDry Contact
(Option)
Green Power(ECO Mode)
Generator Support
High Power Factor
Tower Base
1KVA-3KVA 6KVA-10KVA
Packing
Monitoring software
PHT 1KVA~3KVA 1:1 PHT1102B PHT1103BPHT1101 PHT1102 PHT1103 PHT1101B
MODEL
CAPACITY
Battery Voltage
Size, D X W X H (mm)
Net Weight(kgs)
PHT1103
3000 VA / 2400 W
7.4
PHT1101B
1000 VA / 800 W
36V
397 X 145 X 220)
13
PHT1102B
2000 VA / 1600 W
72V
419 X 190 X 318
26
PHT1103B
3000 VA / 2400 W
28
160VAC/140VAC/120VAC/110VAC±5%
175VAC/155VAC/135VAC/125VAC ±5% 168 VAC / 148VAC / 128 VAC / 118 VAC ± 5 %
300 VAC ± 5 %
290 VAC ± 5 %
40Hz ~ 70 Hz
Single phase with ground
≥0.99 @ nominal voltage (input voltage)
Current Crest Ratio
Harmonic Distortion
Transfer TimeAC Mode to Batt. Mode
Inverter to Bypass
Waveform (Batt. Mode)
3:1
≤3 % THD (Linear Load);≤ 5% THD (Non-linear Load)
0 ms
4 ms
Pure Sine Wave
Battery Type
Battery Numbers
Recharge Time
Charging Current
Charging Voltage
Depending on applications
Depending on applications
Depending on applications
1.0A/2.0A/4.0A/6.0 A
41.0VDC±1%
12V7AH 12V7AH 12V9AH
41.0VDC ±1%
4 hours recover to 90% capacity
1.0 A (max.)
663
Operation Humidity 0-90 % RH @ 0- 40°C (non-condensing)
Noise Level Less than 50dBA @ 1 Meter
PHT1101
1000 VA / 800 W
36V
282 X 145 X 220
4.1
High Frequency Tower UPS
PHT1102
2000 VA / 1600 W
72V
397 X 145 X 220
6.8
Low Line Transfer
Low Line Comeback
High Line Transfer
Voltage Range
High Line Comeback
Overload
200/208/220/230/240VAC
± 1% (Batt. Mode)
47Hz ~ 53 Hz @ 50Hz or 57Hz ~ 63 Hz @ 60Hz
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
≤3 % THD (linear load);≤ 6 % THD (non-linear load)
Output voltage
AC Voltage Regulation
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
Frequency Range
Phase
Power Factor
89% 90% 87%
87% 88% 83% 89%
88%
83%
AC Mode
Battery Mode
90%
87%
82.1VDC±1%82.1VDC±1% 82.1 VDC ±1% 82.1 VDC ±1%
Input
Output
Efficiency
Battery
Environment
Management
Smart RS-232 or USB
Optional SNMP
Windows 2000/2003/XP/Vista/2008、Windows 7/8、Linux、Unix、MAC
Power management from SNMP manager and web browser
105%~110%: UPS shuts down after 10 min at battery mode or transfer to bypass when the utility is normal110%~130%: UPS shuts down after 1min at battery mode or transfer to bypass when the utility is normal>130%:UPS shuts down after 3seconds at battery mode or transfer to bypass when the utility is normal
100%~110%:audible warning110%~130%: UPS shuts down in 60 seconds at battery mode or transfer to bypass when the utility is normal>130%:UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal
Remarks:Products specifications are subject to change without notice.
1KVA~3KVA 1:1Technical Specification
Venus SeriesHigh Frequency Online UPS
PHT1106B PHT1110B PHT1110PHT1106
www.Prostar-cn.com
PHT1106
Current Crest Ratio
Harmonic Distortion
Transfer TimeAC Mode to Batt. Mode
Inverter to Bypass
Waveform (Batt. Mode)
Battery Type
Battery Numbers
Recharge Time
Charging Current
Charging Voltage
12V7AH 12V9AH
16
Low Line Transfer
Low Line Comeback
High Line Transfer
High Line Comeback
Frequency Range
Phase
Power Factor
AC Mode
Battery Mode
PHT1106
6000 VA / 4800 W
192V
369 x 190 x 318
21
PHT1110
10000 VA / 8000 W
442x 190 x 318
23
PHT1106B
6000 VA / 4800 W
369 x 190 x 688
72
PHT1110B
10000 VA / 8000 W
442x 190 x 688
82
110VAC±3% at 50%Load; 176VAC±3% at 100% Load
Low Line Loss Voltage+10V
300 VAC±3 %
High Line Loss Voltage-10V
46Hz~54 Hz@50Hz or 56Hz~64 Hz@60Hz
Single phase with ground
≥0.99 at 100% Load
208/220/230/240VAC
± 1%
46Hz~54 Hz @50Hz or 56Hz~64 Hz @60Hz
50Hz±0.1Hz or 60Hz±0.1Hz
3:1 max
≤3%@100% Linear Load;≤6% @ 100% Non-linear Load
0 ms
0 ms
Pure Sine Wave
Output voltage
AC Voltage Regulation
Frequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
100%~110%: 10min、110%~130%: 1min、>130% :1sec
100%~110%: 30sec、110%~130%: 10sec、>130% : 1sec
Overload
AC Mode
Battery Mode
>89%
>88%
>90%
>89%
>89%
>88%
>90%
>89%
Depending on applications
Depending on applications
Depending on applications
Default : 4A±10%; Max.: 6A±10%
9hours recover to 90% capacity
Default : 1A±10%; Max.: 2A±10%
218.4VDC±1%
0 ~ 40°C (battery life cycle will be shorten when temperature is above 25°C)
<95 % and non-condensing
<1000m
Operation Temperature
Operation Humidity
Operation Altitude
Acoustic Noise Level <55dB@1Meter <58dB@1Meter <55dB@1Meter <58dB@1Meter
UPS High Frequency Tower UPS
Input
Output
Efficiency
Battery
Environment
Management
Smart RS-232 or USB
Optional SNMP Power management from SNMP manager and web browser
Remarks:Products specifications are subject to change without notice.
6KVA~10KVA 1:1Technical SpecificationPHT1106
MODEL
CAPACITY
Battery Voltage
Size, D X W X H (mm)
Net Weight(kgs)
Windows 2000/2003/XP/Vista/2008、Windows 7/8、Linux、Unix、MAC
Voltage Range
www.Prostar-cn.com
ISO9001ISO14001
IQNet
CE RoHS
PHT1101/PHT1101B/PHT1102/PHT1103PHT1106/PHT1110
Function Features
True double-conversion online UPS1
2
3
4
Wide input voltage range (110V-300V)
50/60 Hz Frequency Converter Mode
Lock output frequency at 50Hz or 60Hz to suit power sensitive
equipments.
Mercury series can still provide stable power to connected devices
under unstable power environments.
With pure sine wave output, guarantees compatibility for all kinds
of loads. Its perfect power protection for versatile applications
such as networking, telecom and other mission-critical applications.
Pure sine wave output
5
6
7
8
Output power factor 0.8
Compared to the online UPS in the current market, Mercury
series UPS provides better output power factorup to 0.8. It offers
higher performance and effciency for critical applications.
ECO mode operation for energy saving
Offers efficiency as high as 97% to cut energy usage &cost.
UPS power application via static bypass, timely returning to
online double conversion when the need arises.
Emergency Power Off (EPO) Function
This feature can secure the personnel and equipment in case
of fires or other emergencies.
This feature allows either USB,RS232 or Rj45 communication
port to work with SNMP interface simultaneously.
A true double conversion UPS will provide clean, high level
quality power to fully protect mission-critical devices such as
sensitive networks, small computer centers, servers, telecom
applications, as well as for industrial applications.
Mercury SeriesHigh Frequency Rack UPS
USB+RS232+RJ45+SNMP multiple communication for 1-3K models
PHR1101 PHR1101B PHR1102 PHR1103 PHR1106 PHR1110
External Batery Connection
USB and Rs232 communication PortsIntelligent cooling fanCircuit Breaker Internal Slot
Output terminal
Network/Fax/ModemSurge Protection
AC Input
Humanized panel display and turnable LCD screen
Rack Type
Tower TypeMultifunctional Bracket
Rack/Tower Type Design
Unique Design
Front panel with LCD screen, Intuitive display by way of figures
and graphics etc, LCD screen can rotate freely, and LCD display
can be consistent for both installation of Tower type or Rack
mounted type UPS.
The installation mode of Racks and tower ups can be arbitrary
switching, The hangers for racks and the stents for tower ups
are random standard required, easy for choosing by users.
Rear Panel View
LCD Display
Monitoring Software
USB Port
RS232 Port
Network/Fax/Modem Port
2 x Outlets SNMP Module(Option)
AS-400 CardDry Contact
(Option)
Green Power(ECO Mode)
Generator Support
High Power Factor
Tower Base
www.Prostar-cn.com
Mercury SeriesHigh Frequency Rack UPS
ISO9001
Prostar Science & Technology Development Co.,Ltd.
Http://www.Prostar-cn.com
Pure Sine Wave
Model
Capacity
Battery Voltage
Size, D X W X H (mm)
Net Weight(kgs)
Efficiency
Battery
4 hours recover to 90% capacity
Environment
Management
Input
Low Line Transfer
Voltage Range
Overload
Output
Output voltage
AC Voltage RegulationFrequency Range (Synchronized Range)
Frequency Range (Batt. Mode)
Power management from SNMP manager and web browser
≥0.99 at 100% Load
<95 % and non-condensing
Current Crest Ratio
Harmonic Distortion
Transfer TimeInverter to Bypass
Waveform (Batt. Mode)
3:1 max
0 ms
4 ms
Depending on applications
Depending on applications
Depending on applications
1.0A/2.0A/4.0A/6.0 A ±10%
12V7AH
1.0 A (max.)
3
Low Line Comeback
High Line Transfer
High Line Comeback
Smart RS-232 or USB
Optional SNMP
Frequency Range
Phase
Power Factor
AC Mode
Battery Mode
High Frequency Rack UPS
PHR1101B PHR1101
1000 VA / 800 W
36V
380 x 438 x 88
13 6.5
PHR1102
72V
8.3
PHR1103
2000 VA / 1600 W 3000 VA / 2400 W
72V
480x 438 x 88
10
PHR1106
6000 VA / 4800 W
192V
580 x 438 x 88
15
PHR1110
10000 VA / 8000 W
192V
668 x 438 x 88
18
168VAC/148VAC/128VAC/118VAC ± 5 % )
300 VAC ± 5 %
290 VAC ± 5 %
40Hz ~ 70 Hz
Single phase with ground
≥0.99@nominal voltage (input voltage)
160VAC/140VAC/120VAC/110VAC±5% 110 VAC±3% at 50% Load; 176VAC±3% at100% Load
+10V Low Line Loss Voltage +10V
300VAC±3 %
10V High Line Loss Voltage - 10V
46Hz~54 Hz @ 50Hz or 56Hz~64 Hz@60Hz
200/208/220/230/240VAC
± 1% (Batt. Mode)
47Hz ~ 53 Hz @ 50Hz or 57Hz ~ 63 Hz @ 60Hz
208/220/230/240VAC
± 1%
≤3 % @ 100% Linear Load; ≤6 % @ 100% Non-linear Load
0 ms
87%
83%
90%
87% 89% >88%
>89% >90%
>89%
41.0VDC ± 1% 82.1 VDC ±1% 218.4 VDC ±1%
Noise Level
0 ~ 40°C (battery life cycle will be shorten when temperature is above 25°C)
<1000m
Less than 50dBA @ 1 Meter Less than 55dB @ 1 Meter Less than 58dB @ 1 Meter
50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz
46Hz ~ 54 Hz @ 50Hz or 56Hz ~ 64 Hz @ 60Hz
50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
AC mode :100%~110%: 10minˇ110%~130%: 1minˇ>130% : 1secBattery mode :100%~110%: 30secˇ110%~130%: 10secˇ>130% : 1sec
100%~110%:audible warning110%~130%: UPS shuts down in 60 seconds at battery mode or transfer to bypass when the utility is normal>130%:UPS shuts down immediately at battery mode or transfer to bypass mode when the utility is normal
Battery Type
Battery Numbers
Recharge Time
Charging Voltage
Charging current
Operation Temperature
Operation Humidity
Operation Altitude
Remarks:Products specifications are subject to change without notice.
WeChat Website
1KVA~10KVA 1:1Technical Specification
Windows 2000/2003/XP/Vista/2008、Windows 7/8、Linux、Unix、MAC
AC Mode to Batt. Mode