©2014 waters corporation 1 enhanced ms with the turn of key

22
©2014 Waters Corporation ENHANCED MS WITH THE TURN OF KEY

Upload: evangeline-mccoy

Post on 17-Jan-2016

215 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 1

ENHANCED MS WITH THE TURN OF KEY

Page 2: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 2

Introducing ionKey/MS

What does ionKey/MS™ deliver?

• 2-40x sensitivity vs. your current MS

•UPLC® performance and reliability

•Standardization and consistency

• Flexibility

Page 3: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 3

In Search of a Step Change in

Sensitivity?

Page 4: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 4

Maximizing signal

Maximizing robustness

Xevo® TQ-SA Step Change in Sensitivity

Page 5: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 5

Time1.80 1.90 2.00 2.10 2.20 2.30

%

0

Time1.80 1.90 2.00 2.10 2.20 2.30

%

1

Xevo TQ

Xevo TQ-SEnhanced sensitivity

>25X increase in peak area>5X increase in signal:noise

Rela

tive ion a

bundance

Reserpine (50fg) UPLC/MRM

Xevo TQ-SA Step Change in Sensitivity

Page 6: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 6

Where Next to Look for

Sensitivity?

Page 7: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 7

Where to Next?

75µm ID 150µm ID 300µm ID +

Very Sensitive

Flow rates too low for routine

use

Very Fast

Marginal sensitivity increase

0

Fast and Sensitive

Useable routinely

Page 8: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 8

THE FUTUREOF MS

UPLCPERFORMANCE

YOU KNOW

MORE SENSITIVITY

PLUG ANDPLAY

ROBUSTREPRODUCIBLE

RELIABLE

Page 9: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 9

THE FUTUREOF MS

UPLCPERFORMANCE

YOU KNOW

MORE SENSITIVITY

PLUG ANDPLAY

ROBUSTREPRODUCIBLE

RELIABLE

Page 10: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 10

More Sensitivity

ionKey/MS

20X Increase

Standard 2.1mmcolumn

Page 11: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 11

More Sensitivity

ionKey/MS Standard Flow LC-MS

ionKey/MS

2 Fold suppression in signal due

to Matrix Effects

2.1mm

24 Fold suppression in signal due

to Matrix Effects

Page 12: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 12

THE FUTUREOF MS

UPLCPERFORMANCE

YOU KNOW

MORE SENSITIVITY

PLUG ANDPLAY

ROBUSTREPRODUCIBLE

RELIABLE

Page 13: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 13

UPLC Performance You Know

Page 14: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 14

THE FUTUREOF MS

UPLCPERFORMANCE

YOU KNOW

MORE SENSITIVITY

PLUG ANDPLAY

ROBUSTREPRODUCIBLE

RELIABLE

Page 15: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 15

Sensitivity

ReproducibilityRobustnessUser Expertise RequirementApplicability to Routine

Capillary scale UPLC can be challenging

Page 16: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 16

ionKey/MS is Plug and Play

ENHANCED MS WITH THE TURN OF KEY

Page 17: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 17

THE FUTUREOF MS

UPLCPERFORMANCE

YOU KNOW

MORE SENSITIVITY

PLUG ANDPLAY

ROBUSTREPRODUCIBLE

RELIABLE

Page 18: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 18

Robust, Reliable Reproducible

Retention Time Reproducibility

15 QCs over 500 crashed plasma injections

Reproducibility of the same compound over:

1.64% RSD

5 Systems18 iKeys

5 Users

Page 19: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 19

Validated Assay

Teriparadite (Forteo®) Avg MWT 4117.7

Teriparatide Concentration

(pg/mL)Teriparatide/IS Ratio Response

Calculated Teriparatide

Concentration (pg/mL)

Mean Accuracy

10.00 0.07 10.56 105.6320.00 0.14 20.53 102.6340.00 0.29 38.99 97.5860.00 0.43 57.58 95.97100.00 0.73 97.00 97.00300.00 2.17 286.39 95.50600.00 4.75 626.81 104.451000.00 8.05 1061.49 106.153000.00 22.31 2937.14 97.95

Teriparatide QC

Concentration (pg/mL)

Mean (N=5) Calculated

Concentration (pg/mL) SD %CV

Mean Accuracy

25 25.8887 1.32 5.09 103.6

50 51.4236 1.91 3.72 102.8

80 83.8803 2.15 2.56 104.9

200 202.3569 6.49 3.20 101.2

500 511.1018 15.23 2.98 102.2

Page 20: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 20

THE FUTUREOF MS

UPLCPERFORMANCE

YOU KNOW

MORE SENSITIVITY

PLUG ANDPLAY

ROBUSTREPRODUCIBLE

RELIABLE

Page 21: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 21

The Future of MS

Already over 25 publications and presentations in leading scientific journals and conferences such as:

Journal of Chromatography, Bioanalysis Journal, Journal of Proteomics, ASMS, HPLC, EBF

CPSA, and more.

Page 22: ©2014 Waters Corporation 1 ENHANCED MS WITH THE TURN OF KEY

©2014 Waters Corporation 22