2239 - loopnet · 2020. 8. 6. · 2239. t ave. w ca preliminar set project information project...

16
Presented by: INFILL DEVELOPMENT OPPORTUNITY John Son PRINCIPAL +714.564.7183 [email protected] CA DRE #01069091 Asking Price: $3.2M SITE 22 22 39

Upload: others

Post on 01-Feb-2021

2 views

Category:

Documents


0 download

TRANSCRIPT

  • Presented by:

    INFILL DEVELOPMENT OPPORTUNITY

    John SonP R I N C I PA [email protected] DRE #01069091

    Asking Price:$3.2M

    SITE

    22

    2239

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    PROJECT INFORMATIONProject Address Lot Area Occupancy Construction Type SprinkleredTotal Units proposed Total Parking Spaces Guest Parking Including (1) ADA Elevator Average Residential Unit SF Number of Stories Number of Bedrooms Number of Bathrooms

    PROJECT CONDITIONEntitlement Tract Map Civil Engineering Fire Department Building Department Planning Department Construction Estimate

    7782 Trask Ave, Westminster CA 92683 58,022 (1.3 acres) High Density (15-25 DU/AC) V-BYes20406Yes, in 2 ADA Units:p 7 and 10, Plan 3A 2,06533 and 43 and 4

    In ProgressIn ProgressIn ProgressIn ProgressOn-goingOn-going12 months

    • Rare OC Infill Development Opportunity• Current zoning: R-1 (single family residential)• General plan: Residential High (15-25 units per acre)• City supports high density residential project• Close proximity to shopping and Freeway• Price per unit: $160,000 ($55 PSF)

    PROPERTY HIGHLIGHTS

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    Unit Plan Living Area Garage AreaTotalSq Ft

    1 P2 1,966 467 2,433

    2 P3 2,014 467 2,481

    3 P1 1,998 467 2,465

    4 P2 1,966 467 2,433

    5 P1 1,998 467 2,465

    6 P2 1,966 467 2,433

    7* P3A 2,014 467 2,481

    8 P2 1,966 467 2,433

    9 P1 1,998 467 2,465

    10* P3A 2,014 467 2,481

    11 P1 1,998 467 2,465

    12 P5 2,548 457 3,005

    13 P3 2,014 467 2,481

    14 P2 1,966 467 2,433

    15 P4 2,903 462 3,365

    16 P1 1,998 467 2,465

    17 P3 2,014 467 2,481

    18 P2 1,966 467 2,433

    19 P1 1,998 467 2,465

    20 P3 2,014 467 2,481

    Total

    *Elevator (ADA)

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    PLAT MAP

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    AS NOTED

    SHEET No.

    PROJECT No.

    PRINT DATE

    CHECKED BY

    PLAN DATE

    DRAWN BY

    AT

    MD

    SCALE

    DATEREV. DESCRIPTION

    14542 HARPER ST MIDWAY CITY, CA 92655

    TEL: (714) 330-0096FAX: (888) 601-3001EMAIL: [email protected]

    20 T

    OW

    NH

    OU

    SES

    7782

    TR

    AS

    K A

    VE

    .W

    ES

    TMIN

    STE

    R, C

    A 92

    683

    191114SP

    02/04/20

    02/04/20

    TS

    TITL

    E SH

    EET

    7782 TRASK AVE.WESTMINSTER, CA 92683

    20 TOWNHOUSES

    SYMBOLS

    ABBREVIATIONS FIRE DEPARTMENT NOTES1. FIRE DEPARTMENT VEHICULAR ACCESS ROADS MUST BE INSTALLED AND

    MAINTAINED IN A SERVICEABLE MANNER PRIOR TO AND DURING THE TIME OFCONSTRUCTION. FIRE CODE 501.4

    2. APPROVED BLDG ADDRESS NUMBERS, BUILDING NUMBERS OR APPROVEDBUILDING IDENTIFICATION SHALL BE PROVIDED AND MAINTAINED SO AS TO BEPLAINLY VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE PROPERTY.THE NUMBERS SHALL CONTRAST WITH THEIR BACKGROUND, BE ARABICNUMERALS OR ALPHABET LETTERS, AND BE A MINIMUM OF 4 INCHES HIGH W/ AMINIMUM STROKE WIDTH OF 0.5 INCH. FIRE CODE 505.1

    3. PROVIDE AN APPROVED AUTOMATIC FIRE SPRINKLER SYSTEM AS SET FORTHBY BUILDING CODE 903 AND FIRE CODE 903. PLANS SHALL BE SUBMITTED TOTHE SPRINKLER PLAN CHECK UNIT FOR REVIEW AND APPROVAL PRIOR TOINSTALLATION.

    4. AN APPROVED CARBON MONOXIDE ALARM SHALL BE INSTALLED IN DWELLINGUNITS AND IN SLEEPING UNITS WITHIN WHICH FUEL-BURNING APPLIANCES AREINSTALLED AND IN DWELLING UNITS THAT HAVE ATTACHED GARAGES.REQUIRED CARBON MONOXIDE ALARMS SHALL BE EQUIPPED WITH A BATTERYBACK-UP. WHERE MORE THAN ONE CARBON MONOXIDE ALARM IS REQUIREDTO BE INSTALLED WITHIN THE DWELLING UNIT OR WITHIN SLEEPING UNIT THEALARM SHALL BE INTERCONNECTED IN A MANNER THAT ACTIVATION OF ONEALARM SHALL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT.RESIDENTIAL CODE R315.1.2, BUILDING CODE 420.4.1

    5. WHERE MORE THAN ONE SMOKE ALARM IS REQUIRED TO BE INSTALLED WITHINAN INDIVIDUAL DWELLING OR SLEEPING UNIT, THE SMOKE ALARMS SHALL BEINTERCONNECTED IN SUCH A MANNER THAT THE ACTIVATION OF ONE ALARMWILL ACTIVATE ALL OF THE ALARMS IN THE INDIVIDUAL UNIT RESIDENTIAL CODER314.5

    6. AN AUTOMATIC RESIDENTIAL FIRE SPRINKLERS SYSTEM FOR ONE-ANDTWO-FAMILY DWELLING SHALL BE DESIGNED AND INSTALLED IN ACCORDANCEWITH SECTION R313.3 OR NFPA 130

    7. THE REQUIRED FIRE FLOW FOR A SINGLE PRIVATE ON-SITE FIRE HYDRANT ATTHIS LOCATION IS 1250 GPM AT 20 PSI RESIDUAL PRESSURE. IF MORE THAN ONEON-SITE FIRE HYDRANT IS REQUIRED, THE ON-SITE FIRE FLOW SHALL BE THESAME AS REQUIRED FOR PUBLIC FIRE HYDRANT IN ACCORDANCE WITHAPPENDIX TABLE B105.1. FIRE COD EC106

    8. ALL FIRE HYDRANTS SHALL MEASURE 6''X4''X1-1/2'', BRASS OR BRONZE,CONFORMING TO AMERICAN WATER WORKS ASSOCIATION STANDARD C503, ORAPPROVED EQUAL, AND SHALL BE INSTALLED IN ACCORDANCE WITH THECOUNTY OF LOS ANGELS FIRE DEPARTMENT REGULATION 8.

    9. PROVIDE APPROVED SIGNS OR OTHER APPROVED NOTICES OR MARKINGSTHAT INCLUDE THE WORDS NO PARKING-FIRE LANE. SIGNS SHALL HAVE AMINIMUM DIMENSION OF 12 INCHES WIDE BY 18 INCHES HIGH AND HAVE REDLETTERS ON A WHITE REFLECTIVE BACKGROUND. SIGNS SHALL BE PROVIDEDFOR FIRE APPARATUS ACCESS ROADS, TO CLEARLY INDICATE THE ENTRANCETO SUCH ROAD, OR PROHIBIT THE OBSTRUCTION THEREOF AND AT INTERVALS,AS REQUIRED BY THE FIRE INSPECTOR. FIRE CODE 503.3

    10. ALL ON SITE FIRE HYDRANTS SHALL BE INSTALLED, TESTED AND APPROVEDPRIOR TO BUILDING OCCUPANT. FIRE CODE 901.5.1

    11. PLANS SHOWING UNDERGROUND PIPING FOR PRIVATE ON-SITE HYDRANTSSHALL BE SUBMITTED TO THE SPRINKLER PLAN CHECK UNIT FOR REVIEW ANDAPPROVAL PRIOR TO INSTALLATION. FIRE CODE 901.2, ORANGE COUNTY FIREDEPARTMENT REGULATION 7.

    ZONING CODE: R-1APN: 096-291-20LOT AREA: 58,022 SFOCCUPANCY: HIGH DENSITY (18-25 DU/AC)

    CONSTRUCTION TYPE: V-B

    SPRINKLERED: YESNUMBER OF STORIES: 3HEIGHT: 35'-0"FAR: 39,723/ 58,022 = 72%LOT COVERAGE: 17,592 / 58,022 = 30%

    PROPOSED PARKING:20 UNITS X 2 CAR GARGAGE: 40 SPACESGUEST PARKING INCLUDING (1) ADA: 6 SPACESTOTAL PARKING: 46 SPACES

    UNIT PLAN LIVING GARAGE BALCONY TOTAL 1 P2 334+731+740=1805 467 161 2,433 2 P3 334+741+745=1820 467 194 2,481 3 P1 334+737+749=1820 467 178 2,465 4 P2 334+731+740=1805 467 161 2,433 5 P1 334+737+749=1820 467 178 2,465 6 P2 334+731+740=1805 467 161 2,433 7 P3A 334+741+745=1820 467 194 2,481 8 P2 334+731+740=1805 467 161 2,433 9 P1 334+737+749=1820 467 178 2,465 10 P3A 334+741+745=1820 467 194 2,481 11 P1 334+737+749=1820 467 178 2,465 12 P5 488+939+939=2366 457 182 3,005 13 P3 334+741+745=1820 467 194 2,481 14 P2 334+731+740=1805 467 161 2,433 15 P4 891+904+904=2699 462 204 3,365 16 P1 334+737+749=1820 467 178 2,465 17 P3 334+741+745=1820 467 194 2,481 18 P2 334+731+740=1805 467 161 2,433 19 P1 334+737+749=1820 467 178 2,465 20 P3 334+741+745=1820 467 194 2,481

    DEVELOPER/OWNER:VT DESIGN SPECIALTIES, INC.14542 HARPER STMIDWAY CITY, CA 92655CONTACT: VINNIE TRANPHONE: (714) 330-0096EMAIL: [email protected]

    ARCHITECT:VT DESIGN SPECIALTIES, INC.14542 HARPER STMIDWAY CITY, CA 92655CONTACT: VINNIE TRANPHONE: (714) 330-0096EMAIL: [email protected]

    STRUCTURAL ENGINEER:ND ENGINEERING10692 SILVER CIR,GARDEN GROVE, CA 92843CONTACT: TROY DONGPHONE: (714) 204-2874EMAIL: [email protected]

    ELECTRICAL ENGINEER:DELTA ELECTRIC79362 SALEM AVE.WESTMINSTER, CA 92683CONTACT: WILLIAM TRANPHONE: (714) 899 - 3837EMAIL:[email protected]

    MECHANICAL ENGINEER:PERFECT DESIGN &DEVELOPMENT, INC.2416 W. VALLEY BLVD.ALHAMBRA, CA 91803CONTACT: RAYMOND ZHONGPHONE: (626) 289-8808EMAIL: [email protected]

    CIVIL ENGINEER:ND ENGINEERING, INC.9392 MERIDIAN LANEGARDEN GROVE, CA 92841CONTACT: THANH NGUYENPHONE: (909) 534 - 7760EMAIL: [email protected]

    SOIL ENGINEER:GEOBODEN. INC.5 HODGENVILLE,IRVINE, CA 92620CONTACT: CYRUS RADVAROFFICE PHONE: (949) 872-9565FAX: 949-743-2935

    LANDSCAPE ARCHITECT:TWO TREES DESIGN, INC.1832 SAN DIEGO ST.WEST COVINA, CA 91790CONTACT: CAMILLE PERNGPHONE: 626) 278-2766EMAIL: [email protected]

    CONSULTANTS PROJECT DATA

    1. AT TIME OF PERMIT ISSUANCE, CONTRACTOR SHALL SHOW THEIRVALID WORKER'S COMPENSATION INSURANCE CERTIFICATE.

    2. ALL WORK SHALL CONFORM TO ALL REQUIREMENTS OF STATE OFCALIFORNIA TITLE 24 REGARDLESS OF THE INFORMATIONINDICATED ON THESE PLANS. IT IS THE RESPONSIBILITY OF THEINDIVIDUAL SUPERVISING THE CONSTRUCTION TO ENSURE THATTHE WORK IS DONE IN ACCORDANCE WITH CODE REQUIREMENTSPRIOR TO REQUESTING INSPECTION.

    3. EXCESS OR WASTE CONCRETE MAY NOT BE WASHES INTO THEPUBLIC WAY OR ANY OTHER DRAINAGE SYSTEM. PROVISIONSSHALL BE MADE TO RETAIN CONCRETE WASTES ON SITE UNTILTHEY CAN BE DISPOSED OF AS SOLID WASTE.

    4. SOUTH COAST AIR QUALITY MANAGEMENT DISTRICT (SCAQMD)SHALL BE NOTIFIED IN ACCORDANCE WITH CALIFORNIA STATELAW PRIOR TO START OF ANY DEMOLITION, ADDITION, AND/ ORREMODEL WORK. THE SCAQMD OFFICE IS LOCATED AT 21865COMPLY DRIVE IN DIAMOND BAR, PHONE NO. (909)396-2000. BEADVISED, SCAQMD MAY REQUIRE A 10 DAYS WAIT PERIOD TOSTART OF WORK.

    5. SEDIMENT AND OTHER MATERIALS MAY NOT BE TRACKED FROMTHE SITE BY VEHICLE TRAFFIC. THE CONSTRUCTION ENTRANCEROADWAYS MUST BE STABILIZED SO AS TO INHIBIT SEDIMENTSFROM BEING DEPOSITED INTO THE PUBLIC WAY. ACCIDENTALDEPOSITIONS MUST BE SWEPT UP IMMEDIATELY AND MAY NOT BEWASHED DOWN BY RAIN OR OTHER MEANS.

    6. STOCKPILES OR EARTH AND OTHER CONSTRUCTION RELATEDMATERIALS MUST BE PROTECTED FROM BEING TRANSPORTEDFROM THE SITE BY THE FORCES OF WIND OR WATER.

    7. TRASH AND CONSTRUCTION RELATED SOLID WASTES MUST BEDEPOSITED INTO A COVERED RECEPTACLE TO PREVENTCONTAMINATION OF RAINWATER AND DISPERSAL BY WIND.

    8. FUELS, OILS, SOLVENTS AND OTHER TOXIC MATERIALS MUST BESTORED IN ACCORDANCE WITH THEIR LISTING AND ARE NOT TOCONTAMINATE THE SOIL AND SURFACE WATERS. ALL APPROVEDSTORAGE CONTAINERS ARE TO BE PROTECTED FROM THEWEATHER. SPILLS MUST BE CLEANED UP IMMEDIATELY ANDDISPOSED OF A PROPER MANNER. SPILLS MAY NOT BE WASHEDINTO THE DRAINAGE SYSTEM.

    STATE REQUIREMENT

    ROOF TRUSS UNDER SEPARATE PERMIT OR DEFERREDSUBMITTAL.

    FIRE SPRINKLER SYSTEM UNDER SEPARATE PERMIT ORDEFERRED SUBMITTAL

    SHEET INDEX

    CONSTRUCTION NOTES1. PRIOR TO THE COMMENCEMENT OF CONSTRUCTION ON THE SITE, THE

    DEVELOPER SHALL SCHEDULE A PRE-CONSTRUCTION MEETING BWT THEGENERAL SUPERINTENDENT OR FIELD REPRESENTATIVE AND THE PLANINGDIVISION TO DISCUSS THE APPROVED PLANS AND CONSTRUCTIONREQUIREMENTS.

    2. PRIOR TO THE DEMOLITION OF ANY EXISTING PROPERTY LINE WALLSAND/OR FENCES AND CONSTRUCTION OF A NEW PROPERTY LINE CONCRETEBLOCK WALLS, DE DEVELOP SHALL MAKE REASONABLE EFFORTS TOCOORDINATE AND OBTAIN APPROVAL FROM NEIGHBORING PROPERTYOWNERS TO REMOVE ANY EXISTING WALLS AND/ OR FENCE. WRITTENAUTHORIZATION FROM THE NEIGHBORING PROPERTY OWNER SHALL BEPROVIDED FOR THE REMOVAL OF AN EXISTING WALL AND CONSTRUCTIONOF A NEW PROPERTY LINE WALL UPON SUBMITTAL FOR PLAN CHECK.

    3. NEW INTERIOR AND PERIMETER FENCES AND WALLS FOR THE PROJECT SITESHALL BE OF A DECORATIVE DESIGN USING DURABLE MATERIALS ANDPROTECTIVE SURFACES. THE APPLICATION OF GRAFFITI RESISTANT COATINGAND/OR OTHER ANTI-GRAFFITI MEASURE ARE REQUIRED.

    4. ALL ONSITE UTILITIES SERVICE LINES SHALL BE UNDERGROUND AND NOTVISIBLE TO THE PUBLIC VIEW

    CODE COMPLIANCE2019 CALIFORNIA BUILDING CODE2019 CALIFORNIA ELECTRICAL CODE2019 CALIFORNIA FIRE CODE2019 CALIFORNIA MECHANICAL CODE2019 CALIFORNIA PLUMBING CODE2019 CALIFORNIA RESIDENTIAL CODE2019 CALIFORNIA ENERGY CODE, TITLE 241997 UNIFORM HOUSING CODES1997 UNIFORM CODE FOR ABATEMENT OF DANGEROUS BUILDINGCODE WITH LOCAL AMENDMENTS

    TS TITLE SHEET

    ARCHITECTURAL:

    A - 1 SITE PLAN, PRELIMINARY LANDSCAPE PLAN & COLOR SITE ELEVATIONS

    A - 2 ENLARGED SITE PLAN

    A - 3 PLAN 1FLOOR PLAN, ROOF PLAN, & SECTIONS

    A - 4 PLAN 2FLOOR PLAN & ROOF PLAN

    A - 5 PLAN 3FLOOR PLAN & ROOF PLAN

    A - 6 PLAN 3AFLOOR PLAN & ROOF PLAN

    A - 7 PLAN 4FLOOR PLAN & ROOF PLAN

    A - 8 PLAN 5FLOOR PLAN & ROOF PLAN

    A - 9 ELEVATIONS

    A - 10 ELEVATIONS

    DEFERRED SUBMITTALS

    SCOPE OF WORK

    VICINITY MAP

    - NEW CONSTRUCTION OF 20 TOWNHOUSES, 3-STORY

    - NEW LANDSCAPE, DRIVEWAYS, AND PARKING STALLS

    - NEW COMMON AREA WITH PLAYGROUND AND BBQ'S

    - NEW POLE LIGHTS AT DRIVEWAY AND COMMON AREA

    N

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    388'

    -1"

    218'-1"

    212'

    -8"

    248'-1"

    20'-0"

    DRIVEWAY

    DRIVEWAY

    UNIT 15

    UNIT 12

    UNIT 13

    32'-0" 5'-0" 32'-0" 5'-0" 32'-0" 5'-0" 32'-0" 5'-0" 32'-0"

    UNIT 10

    PLAYGROUND

    25'-0

    "5'

    -0"

    26'-9

    "7'

    -8"

    26'-9

    "

    32'-0

    "5'

    -0"

    32'-0

    "

    18'-5

    "

    52'-3

    "

    PLAN 2

    PLAN 3

    PLAN 4

    25'-1"

    11'-4"26'-9"10'-0"

    2-CARGARAGE

    UNIT 9PLAN 1

    PLAN 1

    2-CARGARAGE

    UNIT 8PLAN 2

    2-CARGARAGE

    UNIT 5PLAN 1

    2-CARGARAGE

    UNIT 6PLAN 2

    2-CARGARAGE

    UNIT 7PLAN 3A

    ADA

    2-CARGARAGE

    UNIT 16PLAN 1

    2-CARGARAGE

    UNIT 17PLAN 3

    2-CARGARAGE

    UNIT 18PLAN 2

    2-CARGARAGE

    UNIT 19PLAN 1

    2-CARGARAGE

    UNIT 20PLAN 3

    2-CARGARAGE

    UNIT 1PLAN 2

    2-CARGARAGE

    UNIT 2PLAN 3

    2-CARGARAGE

    UNIT 3

    2-CARGARAGE

    PLAN 2UNIT 4

    2-CARGARAGE

    2-CARGARAGE

    2-CARGARAGE

    5'-0

    "

    5'-0"32'-0"5'-0"32'-0" 32'-0" 5'-0" 32'-0" 5'-4" 5'-0"

    2-CARGARAGE

    2-CARGARAGE

    UNIT 11

    2-CARGARAGE

    5'-0

    "5'

    -0"

    44'-0

    "19

    '-0"

    5'-0"21'-0"

    11'-0"

    PLAN 1

    PLAN 55'-0"

    10'-6

    "

    UNIT 14

    T

    T

    NO

    PAR

    KIN

    G

    10'-6

    "26

    '-9"

    5'-0

    "

    18'-11"23'-4"111'-0"

    3'-0"

    7'-0

    "21

    '-9"

    10'-0

    "12

    '-9"

    59'-0

    "12

    '-9"

    25'-0

    "

    6

    PLAN 3AADA

    25'-0"

    18'-6"

    9'-0

    "

    AS NOTED

    SHEET No.

    PROJECT No.

    PRINT DATE

    CHECKED BY

    PLAN DATE

    DRAWN BY

    AT

    MD

    SCALE

    DATEREV. DESCRIPTION

    14542 HARPER ST MIDWAY CITY, CA 92655

    TEL: (714) 330-0096FAX: (888) 601-3001EMAIL: [email protected]

    20 T

    OW

    NH

    OU

    SES

    7782

    TR

    AS

    K A

    VE

    .W

    ES

    TMIN

    STE

    R, C

    A 92

    683

    191114SP

    02/04/20

    02/04/20

    A - 2

    ENLA

    RG

    EDSI

    TE P

    LAN

    SCALE:SITE PLAN

    3/32'' = 1'-0''

    N

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    22'-3

    "4'

    -6"

    5'-5"15'-7"11'-0"

    21'-9

    "5'

    -0"

    21'-0"11'-0"

    32'-0"

    26'-9

    "

    UP TO 2NDFLOOR

    2-CAR GARAGE

    1 4''=

    12''

    SLO

    PE

    A/C

    HB

    HB

    HB

    ENTRY

    A

    1 2

    C

    B

    +34'-0''T.O.P

    26'-9

    "

    32'-0"

    20'-0" 12'-0"

    +35'-0''T.O.P

    +35'-0''T.O.P

    +34'-0''T.O.P

    +31'-11''L.P

    +31'-11''L.P

    +32'-6''H.P

    +32'-6''H.P

    FUTURE SOLAR PANEL250 SF

    1 2

    A

    CB.9

    25'-9

    "

    25'-0"

    10'-0

    "

    REF.

    CLOS.

    BEDROOM

    LAUNDRY

    DW

    BATH

    BALCONY

    PANTRY

    KITCHEN

    4'-6

    "15

    '-3"

    26'-9

    "

    11'-11" 15'-7" 4'-6"

    32'-0"

    5'-0

    "4'

    -0"

    5'-6

    "9'

    -3"

    2'-0

    "

    13'-6" 6'-6" 12'-0"

    UP TO 3RDFLOOR

    DINING

    7'-0

    "

    1 2

    A

    CB.9

    BALCONY

    CUSTOM BATH

    BATHW.I.C

    BEDROOM

    BEDROOM

    LIVING ROOM

    BATH

    7'-0

    "10

    '-3"

    9'-6

    "

    26'-9

    "

    4'-4" 9'-10" 13'-4" 4'-6"32'-0"

    14'-3

    "9'

    -6"

    2'-0

    "

    25'-9

    "

    13'-6" 6'-6" 12'-0"

    DN TO 2NDFLOOR

    4'-1

    0"

    1 2

    A

    CB.9

    AS NOTED

    SHEET No.

    PROJECT No.

    PRINT DATE

    CHECKED BY

    PLAN DATE

    DRAWN BY

    AT

    MD

    SCALE

    DATEREV. DESCRIPTION

    14542 HARPER ST MIDWAY CITY, CA 92655

    TEL: (714) 330-0096FAX: (888) 601-3001EMAIL: [email protected]

    20 T

    OW

    NH

    OU

    SES

    7782

    TR

    AS

    K A

    VE

    .W

    ES

    TMIN

    STE

    R, C

    A 92

    683

    191114SP

    02/04/20

    02/04/20

    A - 4

    PLA

    N 2

    FLO

    OR

    PLA

    NR

    OO

    F PL

    AN

    SCALE:FIRST FLOOR

    1/4'' = 1'-0''

    SCALE:SECOND FLOOR

    1/4'' = 1'-0''

    SCALE:THIRD FLOOR

    1/4'' = 1'-0''

    SCALE:ROOF PLAN

    1/4'' = 1'-0''

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    22'-3

    "4'

    -6"

    5'-5" 15'-7" 11'-0"

    21'-9

    "5'

    -0"

    2'-0" 11'-0"

    32'-0"

    26'-9

    "

    UP TO 2NDFLOOR

    2-CAR GARAGE

    1 4''=

    12''

    SLO

    PE

    HB

    ENTRY

    B

    A

    21

    C17'-0" 2'-0"

    A

    C

    1.61.2

    26'-9

    "

    17'-10"

    32'-0"

    +35'-0''T.O.P

    +32'-6''H.P

    +32'-6''H.P

    +34'-0''T.O.P

    +31'-11''L.P+31'-11''

    L.P+35'-0''T.O.P

    +34'-0''T.O.P

    FUTURE SOLAR PANEL250 SF

    14'-2"

    A

    C

    21

    B.9

    25'-0"

    10'-0

    "

    15'-7"

    BEDROOM

    REF.

    15'-0

    "

    UP TO 3RDFLOOR

    1'-0

    "

    26'-9

    "

    10'-9

    "

    BALCONY

    5'-5"

    17'-2"

    11'-0"

    19'-9

    "6'

    -6"

    14'-10"

    32'-0"

    D

    LAUNDRY

    W

    6'-0" 8'-0"

    4'-0

    "

    BATH

    DW

    26'-3

    "

    DINING

    A

    1 2

    PANTRY

    C B.9

    32'-0"

    B

    1.61.2

    531 7

    CUSTOM BATH

    9 11 13

    LIVING ROOM

    BEDROOM

    BEDROOM

    BALCONY

    10'-6

    "1'

    -0"

    15'-3

    "

    26'-9

    "

    17'-4" 10'-4"

    9'-6

    "10

    '-3"

    BATHW.I.C

    2'-0"

    32'-0"

    4'-4"

    BATH

    12'-10" 3'-0" 9'-5"

    32'-0"

    4'-9"

    6'-6

    "

    DN TO 2NDFLOOR

    A

    C

    21

    B.9

    B

    1.61.2

    AS NOTED

    SHEET No.

    PROJECT No.

    PRINT DATE

    CHECKED BY

    PLAN DATE

    DRAWN BY

    AT

    MD

    SCALE

    DATEREV. DESCRIPTION

    14542 HARPER ST MIDWAY CITY, CA 92655

    TEL: (714) 330-0096FAX: (888) 601-3001EMAIL: [email protected]

    20 T

    OW

    NH

    OU

    SES

    7782

    TR

    AS

    K A

    VE

    .W

    ES

    TMIN

    STE

    R, C

    A 92

    683

    191114SP

    02/04/20

    02/04/20

    A - 5

    PLA

    N 3

    FLO

    OR

    PLA

    NR

    OO

    F PL

    AN

    SCALE:FIRST FLOOR

    1/4'' = 1'-0''

    SCALE:SECOND FLOOR

    1/4'' = 1'-0''

    SCALE:THIRD FLOOR

    1/4'' = 1'-0''

    SCALE:ROOF PLAN

    1/4'' = 1'-0''

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    22'-3

    "4'

    -6"

    5'-5" 15'-7" 11'-0"

    21'-9

    "5'

    -0"

    2'-0" 11'-0"

    32'-0"

    26'-9

    "

    UP TO 2NDFLOOR

    2-CAR GARAGE

    1 4''=

    12''

    SLO

    PE

    HB

    ENTRY

    B

    A

    21

    C17'-0" 2'-0"

    ELEVATOR

    A

    C

    1.61.2

    26'-9

    "

    17'-10"

    32'-0"

    +35'-0''T.O.P

    +32'-6''H.P

    +32'-6''H.P

    +34'-0''T.O.P

    +31'-11''L.P+31'-11''

    L.P+35'-0''T.O.P

    +34'-0''T.O.P

    FUTURE SOLAR PANEL250 SF

    14'-2"

    A

    C

    21

    B.9

    25'-0"

    10'-0

    "

    15'-7"

    BEDROOM

    REF.

    15'-0

    "

    UP TO 3RDFLOOR

    1'-0

    "

    26'-9

    "

    10'-9

    "

    BALCONY

    5'-5"

    17'-2"

    11'-0"

    19'-9

    "6'

    -6"

    14'-10"

    32'-0"

    D

    LAUNDRY

    W

    6'-0" 8'-0"

    4'-0

    "

    ADABATHROOM

    DW

    26'-3

    "

    DINING

    A

    1 2

    C B.9

    32'-0"

    B

    1.61.2

    ELEVATOR

    A

    531 7

    CUSTOM BATH

    9 11 13

    LIVING ROOM

    BEDROOM

    BEDROOM

    BALCONY

    10'-6

    "1'

    -0"

    15'-3

    "

    26'-9

    "

    17'-4" 10'-4"

    9'-6

    "10

    '-3"

    BATHW.I.C

    2'-0"

    32'-0"

    4'-4"

    BATH

    12'-10" 3'-0" 9'-5"

    32'-0"

    4'-9"

    6'-6

    "

    DN TO 2NDFLOOR

    A

    C

    21

    B.9

    B

    1.61.2

    A

    AS NOTED

    SHEET No.

    PROJECT No.

    PRINT DATE

    CHECKED BY

    PLAN DATE

    DRAWN BY

    AT

    MD

    SCALE

    DATEREV. DESCRIPTION

    14542 HARPER ST MIDWAY CITY, CA 92655

    TEL: (714) 330-0096FAX: (888) 601-3001EMAIL: [email protected]

    20 T

    OW

    NH

    OU

    SES

    7782

    TR

    AS

    K A

    VE

    .W

    ES

    TMIN

    STE

    R, C

    A 92

    683

    191114SP

    02/04/20

    02/04/20

    A - 6

    PLA

    N 3

    AFL

    OO

    R P

    LAN

    RO

    OF

    PLA

    N

    SCALE:FIRST FLOOR

    1/4'' = 1'-0''

    SCALE:SECOND FLOOR

    1/4'' = 1'-0''

    SCALE:THIRD FLOOR

    1/4'' = 1'-0''

    SCALE:ROOF PLAN

    1/4'' = 1'-0''

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    DN TO 2NDFLOOR

    BATH STUDYROOM

    BATH

    BEDROOMBEDROOM

    BALCONY

    W.I.C

    17'-3" 10'-0" 10'-5" 14'-7"

    52'-3"

    7'-0

    "12

    '-0"

    9'-9

    "

    28'-9

    "

    18'-9"10'-3"6'-0"

    35'-0"

    A

    1

    C C

    21.3

    A

    REF.

    2-CARGARAGE

    KITCHEN

    BAR

    DINING

    CLO

    SE

    T

    26'-9

    "

    31'-3" 21'-0"

    52'-3"

    28'-9

    "

    UP TO 2NDFLOOR

    D W

    LAUNDRY

    PANTRY

    COFFEE STATION

    5'-0

    "

    2ND FLOOR OVERHANG ABOVE

    A

    1

    C

    B B

    2

    2'-0

    "

    22'-3" 9'-0" 2'-0" 17'-0" 2'-0"

    1.3

    A

    C

    UP TO 3RDFLOOR

    LIVING ROOM

    W.I.C

    BATH BATH

    BEDROOM BEDROOM

    BALCONY

    CLO

    SE

    T

    17'-3" 10'-0" 10'-5" 14'-7"

    52'-3"

    7'-0

    "12

    '-0"

    9'-9

    "

    21'-0"14'-0"

    28'-9

    "

    35'-0"

    A

    1

    C C

    21.3

    A

    +35'-0''T.O.P

    28'-9

    "

    52'-3"

    17'-3" 35'-0"

    FUTURE SOLAR PANEL250 SF

    +14'-0''T.O.P

    +11'-6''H.P

    +10'-11''L.P

    +32'-6''H.P

    +31'-11''L.P

    A

    1

    C C

    21.3

    A25'-0"

    10'-0

    "

    AS NOTED

    SHEET No.

    PROJECT No.

    PRINT DATE

    CHECKED BY

    PLAN DATE

    DRAWN BY

    AT

    MD

    SCALE

    DATEREV. DESCRIPTION

    14542 HARPER ST MIDWAY CITY, CA 92655

    TEL: (714) 330-0096FAX: (888) 601-3001EMAIL: [email protected]

    20 T

    OW

    NH

    OU

    SES

    7782

    TR

    AS

    K A

    VE

    .W

    ES

    TMIN

    STE

    R, C

    A 92

    683

    191114SP

    02/04/20

    02/04/20

    A - 7

    PLA

    N 4

    FLO

    OR

    PLA

    NR

    OO

    F PL

    AN

    SCALE:SECOND FLOOR

    1/4'' = 1'-0''SCALE:THIRD FLOOR

    1/4'' = 1'-0''

    SCALE:FIRST FLOOR

    1/4'' = 1'-0''SCALE:ROOF PLAN

    1/4'' = 1'-0''

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    UP TO 3RDFLOOR

    LAUNDRY

    D

    W

    LIVING ROOM

    BEDROOM

    W.I.C

    W.I.C

    STORAGE

    BEDROOM

    BALCONY

    7'-0

    "11

    '-9"

    4'-6

    "

    28'-3

    "

    5'-5" 15'-7" 4'-0" 5'-0" 8'-0" 6'-0"

    44'-0"

    5'-0

    "

    6'-0

    "

    19'-9

    "

    BATH

    BATH

    13'-9

    "

    13'-0" 8'-0"

    LINEN

    A

    B

    C

    2.3

    1

    1 2 3

    D

    E

    A

    3

    2.1

    2-CARGARAGE

    REF.

    KITCHEN

    DINING

    PAN

    TRY

    UP TO 2NDFLOOR

    19'-9

    "

    6'-6

    "11

    '-3"

    21'-3

    "

    21'-0" 23'-0"

    44'-0"

    5'-0

    "2'

    -0"

    2'-0

    "

    3'-0

    "2'

    -0"

    21'-0" 5'-0" 18'-0"

    2ND FLOOR OVERHANG ABOVE

    2ND FLOOR OVERHANG ABOVE

    28'-3

    "

    1 3

    A

    B

    C

    D

    1 3

    E

    A

    2 2.2

    BEDROOM

    BALCONY

    DN TO 2NDFLOOR

    W.I.C

    BATH

    BATH

    W.I.C

    BEDROOM

    RETREAT ROOM

    LINEN7'

    -0"

    11'-9

    "9'

    -6"

    28'-3

    "

    5'-5" 13'-4" 11'-3" 3'-6" 10'-6"

    44'-0"

    13'-9

    "

    4'-0

    "

    6'-0

    "STUDYROOM

    19'-9

    "

    2'-0" 11'-0"

    1'-0"

    3'-10" 3'-2" 2'-0"

    14'-0"3'-6"3'-6"

    A

    B

    C

    1

    1 2 2.3 3

    D

    E

    A

    3

    2.1

    23'-0" 21'-0"

    44'-0"

    8'-6

    "19

    '-9"

    +35'-0''T.O.P

    +31'-6''H.P

    +34'-0''T.O.P

    +30'-11''L.P

    28'-3

    "

    +31'-6''H.P

    +31'-1''L.P

    FUTURE SOLAR PANEL250 SF

    A

    C

    1 3

    E

    A

    25'-0"

    10'-0

    "

    1 32.1

    AS NOTED

    SHEET No.

    PROJECT No.

    PRINT DATE

    CHECKED BY

    PLAN DATE

    DRAWN BY

    AT

    MD

    SCALE

    DATEREV. DESCRIPTION

    14542 HARPER ST MIDWAY CITY, CA 92655

    TEL: (714) 330-0096FAX: (888) 601-3001EMAIL: [email protected]

    20 T

    OW

    NH

    OU

    SES

    7782

    TR

    AS

    K A

    VE

    .W

    ES

    TMIN

    STE

    R, C

    A 92

    683

    191114SP

    02/04/20

    02/04/20

    A - 8

    PLA

    N 5

    FLO

    OR

    PLA

    NR

    OO

    F PL

    AN

    SCALE:SECOND FLOOR

    1/4'' = 1'-0''SCALE:THIRD FLOOR

    1/4'' = 1'-0''

    SCALE:FIRST FLOOR

    1/4'' = 1'-0''SCALE:ROOF PLAN

    1/4'' = 1'-0''

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    ± 0'-0"1ST FLOOR

    2ND FLOOR± 11'-0"

    ± 22'-0"3RD FLOOR

    2'-0" 17'-0" 8'-0"2'-0" 3'-0"

    32'-0"

    T.O.P.

    T.O.P.

    ± 34'-0"

    ± 35'-0"

    - 0'-0''

    - 1'-0''

    - 0'-0''

    - 0'-6''

    - 0'-6''

    - 7'-0''

    - 7'-0''

    -1'-0''-1'-6''

    1'-0"

    10'-0"

    32'-0"

    - 2'-6''

    - 1'-0''

    - 2'-0''

    - 0'-0''

    - 6'-0''

    - 1'-6''

    - 7'-0''

    - 6'-0''

    - 4'-0''

    - 1'-6''

    - 1'-0''

    - 0'-0''

    2'-0" 17'-0" 2'-0"

    0'-0''

    - 2'-0''

    - 7'-0''

    - 1'-6''

    - 5'-0''

    ± 0'-0"1ST FLOOR

    2ND FLOOR± 11'-0"

    ± 22'-0"3RD FLOOR

    T.O.P.

    T.O.P.

    ± 34'-0"

    ± 35'-0"

    2'-0" 17'-0" 2'-0" 5'-0" 2'-0" 10'-0" 6'-0"

    44'-0"

    1ST FLOOR± 0'-0"

    2ND FLOOR± 11'-0"

    3RD FLOOR± 22'-0"

    T.O.P.± 34'-0"

    T.O.P.± 35'-0"

    - 0'-0''

    + 2'-0'' -11'-6''

    - 8'-6''

    - 6'-6''

    - 7'-6''

    - 7'-0''

    - 6'-6''

    +1'-6''

    - 7'-0''

    -8'-6''

    - 5'-0''

    - 5'-0''

    +1'-0''

    AS NOTED

    SHEET No.

    PROJECT No.

    PRINT DATE

    CHECKED BY

    PLAN DATE

    DRAWN BY

    AT

    MD

    SCALE

    DATEREV. DESCRIPTION

    14542 HARPER ST MIDWAY CITY, CA 92655

    TEL: (714) 330-0096FAX: (888) 601-3001EMAIL: [email protected]

    20 T

    OW

    NH

    OU

    SES

    7782

    TR

    AS

    K A

    VE

    .W

    ES

    TMIN

    STE

    R, C

    A 92

    683

    191114SP

    02/04/20

    02/04/20

    A - 9

    ELEV

    ATIO

    NS

    SCALE:FRONT ELEVATION PLAN 1

    1/4'' = 1'-0'' SCALE:FRONT ELEVATION PLAN 2

    1/4'' = 1'-0''

    SCALE:FRONT ELEVATION PLAN 5

    1/4'' = 1'-0''

  • 7782 Trask Ave. | Westminister CA 20 Houses PRELIMINARY SET

    1ST FLOOR± 0'-0"

    2ND FLOOR± 11'-0"

    3RD FLOOR

    2'-0"17'-0"

    ± 22'-0"

    2'-0"

    32'-0"

    - 2'-6''

    - 7'-0''

    - 7'-0''

    - 6'-0''

    - 0'-6''

    T.O.P.

    - 1'-6''

    - 0'-0''

    ± 34'-0"

    T.O.P.± 35'-0"

    9'-0"

    - 6''

    0'-0''

    - 6''

    - 0''

    2'-0"

    - 6''

    OPEN

    26'-9"

    3'-0"2'-0" 14'-3" 3'-0" 4'-6"

    1ST FLOOR± 0'-0"

    2ND FLOOR± 11'-0"

    3RD FLOOR± 22'-0"

    T.O.P.± 34'-0"

    26'-9"

    1ST FLOOR± 0'-0"

    2ND FLOOR± 11'-0"

    3RD FLOOR± 22'-0"

    T.O.P.± 35'-0"

    32'-0"

    1ST FLOOR± 0'-0"

    2ND FLOOR± 11'-0"

    3RD FLOOR± 22'-0"

    T.O.P.± 35'-0"

    1ST FLOOR± 0'-0"

    2ND FLOOR± 11'-0"

    3RD FLOOR± 22'-0"

    ± 35'-0"T.O.P.

    ELEVATION 4

    - 5'-0''

    + 2'-0''

    - 0'-0''

    -5'-0''-0'-0''-0'-0''

    +2'-0'' +1'-6''+1'-0''

    3'-0" 12'-0" 7'-3" 9'-0" 2'-0" 17'-0" 2'-0"

    52'-3"

    - 7'-0''

    AS NOTED

    SHEET No.

    PROJECT No.

    PRINT DATE

    CHECKED BY

    PLAN DATE

    DRAWN BY

    AT

    MD

    SCALE

    DATEREV. DESCRIPTION

    14542 HARPER ST MIDWAY CITY, CA 92655

    TEL: (714) 330-0096FAX: (888) 601-3001EMAIL: [email protected]

    20 T

    OW

    NH

    OU

    SES

    7782

    TR

    AS

    K A

    VE

    .W

    ES

    TMIN

    STE

    R, C

    A 92

    683

    191114SP

    02/04/20

    02/04/20

    A - 10

    ELEV

    ATIO

    NS

    SCALE:REAR ELEVATION PLAN 3 & 3A

    1/4'' = 1'-0'' SCALE:FRONT ELEVATION PLAN 4

    1/4'' = 1'-0''

    SCALE:FRONT ELEVATION PLAN 3 & 3A

    1/4'' = 1'-0'' SCALE:RIGHT SIDE ELEVATION PLAN 3 & 3A

    1/4'' = 1'-0'' SCALE:LEFT SIDE ELEVATION PLAN 3 & 3A

    1/4'' = 1'-0''

  • ALL INFORMATION CONTAINED HEREIN HAS BEEN PROVIDED BY SELLER, LANDLORD, AND/OR THIRD PARTIES, BUT HAS NOT BEEN INDEPENDENTLY VERIFIED BY LEE & ASSOCIATES OR ITS AGENT(S). BUYER, TENANT AND/OR INTERESTED PARTIES SHOULD INDEPENDENTLY VERIFY ALL INFORMATION COMMUNICATED BY THESE SOURCES. LOCATION OF NEIGHBOURING TENANT’S AND ACTUAL OCCUPANTS ARE SUBJECT TO CHANGE. NO WARRANTY OR REPRESENTATION HAS BEEN MADE TO ACCURACY OF THE FOREGOING INFORMATION. BUYER TO VERIFY AT THEIR DISCRETION.

    EXCLUSIVE AGENT

    John SonP R I N C I PA L

    [email protected] A L D R E # 0 1 0 6 9 0 9 1

    Lee & Associates Commercial Real Estate Services, Inc.1004 W. Taft Avenue, Suite 150, Orange, CA 92865LeeOrange.com | CORPORATE ID# 0101126