305 mccb hager range

Upload: qinayabee

Post on 03-Apr-2018

284 views

Category:

Documents


6 download

TRANSCRIPT

  • 7/28/2019 305 MCCB Hager Range

    1/34

    HDC Series MCCB

    2006/2007

    En-2006-1

    COVEROFH STMF.indd 3 1/20/04 10:07:12 AM

  • 7/28/2019 305 MCCB Hager Range

    2/34

    the success is in the system

    Welcome to the Hager HDC series moulded case circuit breaker 2006/2007

    catalogue. You will get to know more detailed information about the Hager

    distribution system.

    Hager provides a complete range of distribution system products for you. We have

    labeled products with corresponding color coded pictogram for you to know more

    about Hager product.

    If you have any suggestion or request for help, please contact your nearest Hager

    office.

    Distribution boards

    Widely used as the distribution board in residential building

    and commercial purpose that includes plastic type and

    metal type. Hager provides complete range of distribution

    enclosures for commercial and industrial distribution system.

    Modular protection devices & main switchgear

    Modular protection devices include: miniature circuit breaker,

    residual current circuit breaker, fuse carrier, contactor, time

    switch, surge protection device, isolating switch, etc. and

    related auxiliary equipment and accessory.

    Main switchgear product includes: moulded case circuit

    breaker, load break switch, etc.

    Connection devices

    Connection block, connector, bus bar and terminals.

    Wiring Accessories

    Hager wiring accessories include: system 8000, 9000, 9088,

    metallic range, door bell, emergency light, etc.

    Intelligent building management system

    Hager provides a complete set of devices for intelligent

    building management system, which includes: timer,

    temperature controller, presence detector, building automation

    system based on EIB bus system, remote control system, etc.

    Cable management system

    Hager provides a complete set of cabling system for cable

    management system.

    Security systemHager security system includes smoke detector, monitoring

    system, entrance guard system, anti-intrusion alarm, etc.

    HDCCATAL STMF.indd 1 1/23/04 12:12:31 PM

  • 7/28/2019 305 MCCB Hager Range

    3/34

    Hager is originated from

    Germany in 1955 as a

    manufacturer of low voltage

    distribution system with

    European leading technology

    that provides a complete solution

    suitable for residential, industrial

    and commercial application with

    reliable connection devices and

    modular devices for protection,

    control and measurement.

    To meet the requirement of

    the market as well as service

    demanded by our partners and

    customers, Hager has designed

    a short production cycle and

    efficient production process.

    By integrating flexibility and

    creativity, comprehension of

    the international market as well

    as advanced development and

    research technology, these

    factors guarantee Hager as an

    excellent international brand.

    Today, Hagers more than 20

    production bases are located

    over the world. Our product

    is present in more than 40

    countries and meets local

    requirement and standard.

    Hager has a reliable and well

    organised sales team. Our local

    sales company and partners

    together provide excellent

    product and service for all our

    customers.

    Hager Group

    Made by hager is the guarantee

    of product quality for the whole

    system.

    2

    HDCCATAL STMF.indd 2 1/23/04 12:12:38 PM

  • 7/28/2019 305 MCCB Hager Range

    4/34

    the success is in the system

    3

    HDCCATAL STMF.indd 3 1/23/04 12:12:47 PM

  • 7/28/2019 305 MCCB Hager Range

    5/34

    4

    Product Range Summary

    HDC series

    moulded case

    circuit breaker

    HDC series MCCB

    125A frame and

    accessory

    Page 12

    HDC series MCCB

    250A frame and

    accessory

    Page 14

    HDC series MCCB

    800A frame and

    accessory

    Page 16

    Technical

    information

    28

    Product Description of H D C Serial MCCB

    a d

    aa

    bb b

    c

    F ramecapacity

    Modelframe

    Numberofpoles

    Rated current( A)

    5VCPFCTFCODKGPVVGORGTCVWTG

    Ratedi solation voltageU i (V)

    Rated limited shortbreakingcapacityIcu(k A)

    GB14048.2IEC60947-2EN60947-2 Icu / Ics

    400V A C

    Externaldimension (mm)

    Weight (kg)

    S tandard function and characteristic

    Releasemethod

    Releasetestingbutto n

    Break indicatinglamp

    Manualsafety device(O FF-Lock)

    *Onlyappl icablefor HXA /B /C/D033

    Connection

    method

    Life

    Frontboardconnectingl ine

    125A 250 A 4 00 A 8 00 A

    h 125 t c , h125td,h 125t n h250tc,h 250t d h 400tnh 800tn

    3 4 3 4 3 4 3 4

    16, 20,25, 32,

    40,5 0,63,80,

    100,125

    125,160,

    200,225,250

    250

    320

    400

    500

    630

    800

    690V A C

    Icu /Ics

    18/1425 /19

    35 /25

    690 V A C 69 0V A C 690 V A C

    25/19

    35/255 0/35 5 0/35

    Icu /Ics Icu/ Ics I cu/Ics

    a

    b

    c

    d

    aa

    bb

    155 165 260 273

    86 86 103 103

    104 10 4 1 30 145

    30 35 45 70

    1 32 1 26 2 14 2 43

    9 0 1 2 0 1 05 1 40 1 4 0 1 7 3 2 1 0 2 79

    1 . 4 1 .9 1 . 8 2 . 4 5.3 7 9. 4 1 2 .5

    Therm al-m agnetic T h e r ma l - m ag n e t ic Therm al-m agnetic (adjus table)

    8000 60 00 3 00 0 2500

    1 00 0 0 8 00 0 6000 6000

    .!

    .!

    .!

    .!

    .! .! .!

    .!

    .! .! .!

    Right

    :Appl ic able(purc has eaddi tional ly ) .:Notappl ic able

    Therm al-m agnetic (adjus table)

    Rearboardconnectingline

    Plug-intypeconnectingline

    Draw-outtypedevice

    Attacheddevicecanbei nstalledadditionally

    Internal

    accessory

    External

    accessory

    Shunttrip

    Undervoltagetrip

    AuxiliaryswitchAUX

    AlarmswitchALM

    Auxiliaryalarmsw itch AUX+A LM

    Electric driving operating mechanism

    Rotaryhandledevice

    Auxiliaryhandle

    Interlacingdivisionboard

    Extended

    Electriclife(timeofoperation)

    Mechanicallife(ti meofoperation)

    Right

    Right

    Right

    Right

    RightRight

    Right

    Right

    Left

    Left,right

    Left,right

    Left,right

    LeftLeft

    Left

    Left

    Left,right

    Left

    Left

    HDC series MCCB

    Product description

    Page 18

    33

    Characteristic Curve of H D C Serial MCCB

    16

    20

    32

    40506080

    100

    125

    208 42

    260 52

    416 83520 104650 130

    819 164975 195

    1300 260

    1625 325

    125

    160

    200

    225

    250

    1594 281

    2040 3602550 450

    2869 5 06

    3188 563

    125Arelease curve 250Arelease curve

    400Arelease curve 800A releasecurve(In:500A- 630A)

    4

    3

    2

    150

    4 03 0

    2 0

    1 0

    8

    654

    3

    2

    1

    504 0

    3 0

    2 0

    1 08

    6543

    2

    10 .8

    0 .60 .5

    0 .40 .3

    0 .2

    0 .1

    0.080 . 060 . 050.04

    0.03

    0.02

    0.01

    0.008

    0.00 60.00 5 08 09 001

    521

    002052

    003004

    005006

    007008

    009

    0001

    0051

    0002

    0052

    0003

    0004

    0005

    0006

    0007

    0008

    051

    DNOCES

    ETUNIM

    RUOH

    50 050 0 050 0

    X 5X 1 0

    5

    63 0 63 0 063 0

    Tripcurrent value

    Ther e ar e 5phases that canbe adjust ed wi t hin adjust abl er ange of elect r omagnet t r ip

    Rated c urrent(A)

    h800 t

    Actiontime

    %ofratedc urrents etvalueinc om paris on

    Trip c urrentv alue(A) (x 10)

    M in

    Max

    40004 0 0

    Trip c urrentv alue

    32003 2 0250 0250

    4 0 0

    2503 2 0

    0.010 . 0 0 8

    0.00 60.00 5

    0 .10.08

    0 . 060 . 05

    0.03

    0.02

    0.04

    0 .8

    0 .60 .50 .40 .3

    0 .2

    NOCES

    D

    1

    1 0

    2

    43

    8

    56

    504 03 0

    2 0

    1

    2

    1 0

    ETUNIM

    4

    3

    568

    4 0

    3 0

    50

    RUOH

    1

    3

    2

    4

    2 0

    0908 0 1

    021

    551

    002

    052

    003

    004

    005

    006

    007

    0 0 001

    09

    008

    0 0051

    0052

    0002

    0003

    0004

    0005

    0008

    0007

    0006

    Min

    LO HI Ther e ar e5 phases t hat canbe adjusted wi t hin adjustabl e

    range of elect r omagnet t rip

    Ratedc urrent(A)

    h400tn

    Max

    Actiontime

    %ofratedc urrents etv alueinc om paris on

    Tripc urrentv alue(A)

    16A~32AM ax

    40A~125AM ax

    20A~32AM in

    40A~125AM in

    Tripc urrentv alue

    Ratedc urrent(A)TripCurrent(A)

    Tripc urrentv alue

    Ratedc urrent(A)TripCurrent(A)

    Act

    io nt ime

    Act io nt ime

    %ofrated c urrents etv aluei n compar is on %ofrated c urren ts etv alue in compar i s on

    HDC series MCCB

    Characteristic curve

    Page 23

    35

    HDCSerial MCCB Accessory

    42

    65

    65

    4.5

    200

    45

    5 3

    36

    2- 5 .50200

    42

    65

    65

    4.50

    200

    80

    8 0 H

    61

    H

    93

    9 3

    H

    Ref.No.HXA031HXB031

    HXC031HXD031

    H

    6565

    9595

    H

    65659595

    HXA032HXB032HXC032HXD032

    H

    65659595

    HXA033HXB033HXC033HXD033

    OFF positioncaninstalllocktool(applicablefor HX*033)

    Optionalaccessory

    Standard configured EH1rotary handledevice

    HXC031

    HXC032

    HXC033

    Install on distribution boxdoor

    Protectionlevel:HX*031/HX*032IP30H X *0 3 3 I P 65

    Rotary handle

    Ref.No.

    Ref.No.

    HDC series MCCB

    Accessory

    Page 25

    32

    DimensionD escription of HDCSerial MCCB

    125Aframe

    F r o ntw i n d ow s i z e 3 p o l es

    55

    28

    R1

    1 3 2 15

    5

    90

    30

    M4X0.7Fix edSc r

    N

    1 3 2 15

    5

    120

    60

    1 0 2

    86

    104

    5 2

    28

    R2

    165

    1 26

    M4X0.7Fix edSc r

    35

    105

    165

    1 26

    70

    140

    86

    104

    R2

    9 2

    64

    M6X0.7Fix edSc r

    260

    140

    45

    131

    129

    108

    106

    260

    173

    135

    45

    131

    129

    108

    106

    N

    45

    131

    697

    103

    55

    47

    9 2

    64

    M8X0.7Fix edSc r

    1 4 1

    70

    210

    1 3 2

    8 0

    70

    8 0

    40

    126

    117

    70 70

    1 4 1

    279

    1 3 2

    8 0

    8 0

    126

    117

    7.5

    32

    103

    6

    348

    14580.5

    8

    5 7

    4 5

    4 p ol es L at er al f ac e

    250Aframe

    F ro nt w in do w s iz e 3 po le s 4 p ol es L at er al f ac e

    400AframeF ro nt w in do w s iz e 3 po le s 4 p ol es L at er al f ac e

    800AframeF ro nt w in do w s iz e 3 po le s 4 p ol es L at er al f ac e

    HDC series MCCB

    Dimension

    Page 22

    29

    Model Labeling Method of H D C Serial MCCB

    Model labeling method of MCCB

    1.Mainproduct number

    2.Productcategory&br eakingcapacity

    D=16-18kAmouldedcasecircuitbreaker

    H=25kAmouldedcaseci rcuitbreaker

    N=35-50kAmouldedcasecircuitbreakerX=auxiliarydevice

    Y=accessory

    3.Frametype

    A=125frame

    B=250frame

    C=400frameD=800frame

    4.Ratedcurrent

    3poles4poles

    1 6 A = 01 6 0 1 7

    2 0 A = 02 0 0 2 1

    2 5 A = 02 5 0 2 6

    3 2 A = 03 2 0 3 3

    4 0 A = 04 0 0 4 1

    5 0 A = 05 0 0 5 16 3 A = 06 3 0 6 4

    8 0 A = 08 0 0 8 1

    5.Serial

    C=lowprofile

    D=intermediateprofile

    Note: If accessory is ordered with moulded case circuit breaker together,please fill moulded case circuit breaker numb er and accessorynumber

    insteadofprod uctnumberon ordersheet. Ifaccessoryisor deredindividually,then youjustfillaccessor ynumber.Fore xample , y o u o r d e r 1 2 5frame16A,35kA andoperati ngrotaryhan dledevicewithcentr alregulatingcrank structure,andthen youshoul dwriteHNA016D/ HX031-EH1.

    ifaccessoryisor derindividually,then itshouldbeHX031-EH1.

    SHT(shunttri p)l

    Shunttripisused tocontrolgate off

    atlongdistancel

    Instantaneousworking mechanisml

    Optionalaccessoryl

    Operationcharacteri stic(seetable 1)

    UVT(undervoltagetrip)l

    Undervoltagetripis usedtoprovide undervoltage

    protectionforci rcuitandelectric devicel

    Undervoltagetripcan beusedasshun ttriploperation

    Characteristic(seetab le2)

    Shunt Trip SHT, Undervoltage Trip UVT

    1.Mainproduct number

    Shunttri p ( t a b l e 1 )

    Undervoltagetrip( table2)

    Operatingelectricacce ssory

    Operatingpower voltagerange

    Ratedcontrolpower voltage

    Operatingelectrica ccessory

    Operatingvoltage

    Guaranteedswitch-on voltage

    Guaranteedswitch-off voltage

    Shunttrip

    (0.7-1.1)xUn

    24VAC

    (0.35-0.7)xUe

    (0.85-1.17)xUe

    0.35-Ue

    24VDC

    1 10 VA C 2 3 0V AC 4 00 VA C

    2 3 0 VA C 4 0 0 VA C

    H

    H

    2.Auxiliarydevice

    3.Frametype

    A=125frame

    B=250frameC=400frame

    D=800frame

    4.Voltageused

    Shuntrelease:006=24VDC

    001=24VAC

    003=110VAC004=230VAC

    005=400VAC

    Undervoltagerelease:014=230VACbelow

    015=400VACbelow

    5.Installationlocation

    R=installatrightsi de

    L-installatleftside

    X

    3pole s 4 p o l e s

    1 0 0 A =1 0 0 1 0 1

    1 2 5 A =1 2 5 1 2 61 6 0 A =1 6 0 1 6 1

    2 0 0 A =2 0 0 2 0 1

    2 2 5 A =2 2 5 2 2 6

    2 5 0 A =2 2 5 2 5 1

    3 2 0 A =3 2 0 3 2 1

    4 0 0 A =4 0 0 4 0 15 0 0 A =5 0 0 5 0 1

    6 3 0 A =6 3 0 6 3 1

    8 0 0 A =8 0 0 8 0 1

    Modellabelingmethod

    HDC series MCCB

    Product reference

    numbers

    Page 19

    HDC series MCCB

    400A frame and

    accessory

    Page 15

    HDCCATAL STMF.indd 4 1/23/04 12:13:06 PM

  • 7/28/2019 305 MCCB Hager Range

    6/34

    5

    Product Selection Chart

    Rated Insulation voltage

    Ui (V)

    125A 250A 400A 800A

    690 V AC 690 V AC 690 V AC690 V AC

    Breaking

    capacity (kA)

    H125TC

    16 A

    20 A

    25 A

    32 A

    40 A

    50 A

    63 A80 A

    100 A

    125 A

    HDA016A HDA017A

    HDA020A HDA021A

    HDA025A HDA026A

    HDA032A HDA033A

    HDA040A HDA041A

    HDA050A HDA051A

    HDA063A HDA064AHDA080A HDA081A

    HDA100A HDA101A

    HDA125A HDA126A

    H125TD

    HHA016A

    HHA020A

    HHA025A

    HHA032A

    HHA040A

    HHA050A

    HHA063A

    HHA080A

    HHA100A

    HHA125A

    H125TN

    HNA016A

    HNA020A

    HNA025A

    HNA032A

    HNA040A

    HNA050A

    HNA063A

    HNA080A

    HNA100AHNA125A

    HNA017A

    HNA021A

    HNA026A

    HNA033A

    HNA041A

    HNA051A

    HNA064A

    HNA081A

    HNA101AHNA126A

    HHA017A

    HHA021A

    HHA026A

    HHA033A

    HHA041A

    HHA051A

    HHA064A

    HHA081A

    HHA101A

    HHA126A

    Rated

    Current

    / A

    H250TC

    HHB125AHHB160A

    HHB200A

    HHB225A

    HHB250A

    H250TD

    HHB126AHHB161A

    HHB201A

    HHB226A

    HHB251A

    HNB125A

    HNB160A

    HNB200A

    HNB225A

    HNB250A

    HNB126A

    HNB161A

    HNB201A

    HNB226A

    HNB251A

    H400TN

    HNC250A

    HNC320A

    HNC400A

    HNC251A

    HNC321A

    HNC401A

    H800TN

    HND500A

    HND630A

    HND800A

    HND501A

    HND631A

    HND801A

    16 A

    20 A

    25 A

    32 A

    40 A

    50 A

    63 A

    80 A

    100 A

    125 A160 A

    200 A

    225 A

    250 A

    16 A

    20 A

    25 A

    32 A

    40 A

    50 A

    63 A

    80 A

    100 A125 A

    160 A

    200 A

    225 A

    250 A

    250 A

    320 A

    400 A

    500 A

    630 A

    800 A

    18

    25

    35

    50

    Ref.No.

    4 pole

    Ref.No.

    3 pole

    Ref.No.

    4 pole

    Ref.No.

    3 pole

    Ref.No.

    4 pole

    Ref.No.

    3 pole

    Ref.No.

    4 pole

    Ref.No.

    3 pole

    HDCCATAL STMF.indd 5 1/23/04 12:13:18 PM

  • 7/28/2019 305 MCCB Hager Range

    7/34

    Complies with IEC60947-2

    standard

    Rated current ranges from

    16A to 800A

    With four frame sizes for

    selection

    Easy to install and maintain

    Compact structure, practical

    functionality

    Flexible and convenient

    connection

    Comprehensive specification,various function, wide

    application

    High reliability and safety

    Number of poles for main

    circuit: 3 poles and 4 poles

    Adjustable 400 and 800 frame

    electromagnetic release

    125A frame

    Rated current: 16A~125A

    Breaking capacity: 18kA, 25kA,35kA

    Rated insulation voltage: 690V

    HDC Series Moulded Case Circuit Breaker

    6

    HDCCATAL STMF.indd 6 1/23/04 12:13:33 PM

  • 7/28/2019 305 MCCB Hager Range

    8/34

    250A frame

    Rated current: 125A~250A

    Breaking capacity: 25kA,35kA

    Rated insulation voltage: 690V

    400A frame

    Rated current: 250A~400A

    Breaking capacity: 50kA

    Flexible and adjustable

    protection range

    800A frameRated current: 500A~800A

    Breaking capacity: 50kA

    Flexible and adjustable

    protection range

    7

    Draw-out type device

    Available for 400A and 800A frame

    Device with small volumeThree connection type

    Meets functionality requirement,

    with safety and reliability

    Capable of connecting or

    breaking main circuit and

    secondary circuit

    With safe and reliable interlock

    function

    HDCCATAL STMF.indd 7 1/23/04 12:13:46 PM

  • 7/28/2019 305 MCCB Hager Range

    9/34

    Product Structure Of HDC Series

    Moulded Case Circuit Breaker

    1.HDC MCCB

    2.Shunt trip

    3.Undervoltage trip

    4.a. Auxiliary switch

    b. Alarm switch

    c. Auxiliary/alarm switch

    5.Rotary handle

    6.Rotary handle accessory

    7.Motor mechanism

    8.Interphase barrier

    9.Extended bus bar

    10.Rear connection (fixed type)11.Rear connection (plug-in type)

    12.Draw-out type device

    Note: Item 2, 3, 4 are required

    to be installed in factory. Please

    contact the hager sales office or

    agent when ordering.

    3

    9

    5

    5

    11

    10

    7

    8

    4b

    1

    4a

    4c

    2

    10

    5

    6

    8

    HDCCATAL STMF.indd 8 1/23/04 12:14:13 PM

  • 7/28/2019 305 MCCB Hager Range

    10/34

    1

    8

    4b

    2

    3

    1110

    4a7

    12 1

    4c

    5

    5

    6

    5

    9

    9

    HDCCATAL STMF.indd 9 1/23/04 12:14:34 PM

  • 7/28/2019 305 MCCB Hager Range

    11/34

    10

    HDCCATAL STMF.indd 10 1/23/04 12:14:34 PM

  • 7/28/2019 305 MCCB Hager Range

    12/34

    Moulded Case Circuit Breaker

    12 HDC series MCCB 125A frame

    14 HDC series MCCB 250A frame

    15 HDC series MCCB 400A frame

    16 HDC series MCCB 800A frame

    11

    HDCCATAL STMF.indd 11 1/23/04 12:14:34 PM

  • 7/28/2019 305 MCCB Hager Range

    13/34

    12

    HDC Series MCCB 125A Frame

    Frame type: H125TC,H125TD,

    H125TN

    Description:

    Hager moulded case circuitbreaker provides various

    options and wide choice for

    the contractor, switch-board

    manufacturer and distributor.

    H125TC

    Icu : 18 kA

    Ue : 380/400 V AC

    Ui : 690 V

    16 A

    20 A

    25 A

    32 A

    40 A

    50 A

    63 A

    80 A

    100 A

    125 A

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    HDA016A HDA017A

    HDA020A HDA021A

    HDA025A HDA026A

    HDA032A HDA033A

    HDA040A HDA041A

    HDA050A HDA051A

    HDA063A HDA064A

    HDA080A HDA081A

    HDA100A HDA101A

    HDA125A HDA126A

    H125TD

    Icu : 25 kA

    Ue : 380/400 V AC

    Ui : 690 V

    16 A

    20 A

    25 A

    32 A

    40 A

    50 A

    63 A

    80 A

    100 A

    125 A

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    HHA016A

    HHA020A

    HHA025A

    HHA032A

    HHA040A

    HHA050A

    HHA063A

    HHA080A

    HHA100A

    HHA125A

    H125TN

    Icu : 35 kA

    Ue : 380/400 V AC

    Ui : 690 V

    16 A

    20 A

    25 A

    32 A

    40 A

    50 A

    63 A

    80 A

    100 A

    125 A

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    HNA016A

    HNA020A

    HNA025A

    HNA032A

    HNA040A

    HNA050A

    HNA063A

    HNA080A

    HNA100A

    HNA125A

    HNA017A

    HNA021A

    HNA026A

    HNA033A

    HNA041A

    HNA051A

    HNA064A

    HNA081A

    HNA101A

    HNA126A

    HHA017A

    HHA021A

    HHA026A

    HHA033A

    HHA041A

    HHA051A

    HHA064A

    HHA081A

    HHA101A

    HHA126A

    102

    86

    104

    Technical parameter:

    Complies with IEC 60947-2

    standard

    Ultimate rated short-circuit

    breaking capacityFrame 400V AC

    H125TC 18kA

    H125TD 25kA

    H125TN 35kA

    HHA016A

    HNA126A

    N

    For technical information,see

    page 17-29

    Designation Pack

    Qty

    Current

    Rating(A)

    Ref.No.

    4 pole

    Ref.No.

    3 pole

    HDCCATAL STMF.indd 12 1/23/04 12:14:39 PM

  • 7/28/2019 305 MCCB Hager Range

    14/34

    13

    Shunt trip 24 V DC

    24 V AC

    110 V AC

    230 V AC

    400 V AC

    HXA006A

    HXA001A

    HXA003A

    HXA004A

    HXA005A

    Undervoltage trip 230 V AC

    400 V AC

    HXA014A

    HXA015A

    Auxiliary switch

    Alarm switch

    Auxiliary/Aalarm switch

    1NO + 1NC

    1NO + 1NC

    1NO + 1NC / 1NO + 1NC

    HXA021A

    HXA024A

    HXA023A

    Rotary handle Selectable rotary handle accessory EH1/EH2

    Selectable rotary handle accessory EH1/EH2

    Selectable rotary handle accessory EH1/ EH2

    HXA031A

    HXA032A

    HXA033A

    Interphase barrier HYA020A

    Rear connection Fixed type

    Plug-in type

    HYA031A

    HYA041A

    Motor

    mechanism

    HXA041A

    HXA042A

    24 V DC

    110 V AC/DC 220 V AC/DC

    HXA006A

    HXA001A

    HXA003A

    HXA004A

    HXA005A

    HXA014A

    HXA015A

    HXA021A

    HXA024A

    HXA023A

    HXA031A

    HXA032A

    HXA033A

    HXA041A

    HXA042A

    HYA019A

    HYA030A

    HYA040A

    HXA032A

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    HXA004A

    HXA031A

    HXA033A

    Designation Ref.No.

    4 pole

    Ref.No.

    3 poleCharacteristics Pack

    Qty

    Installation

    location.

    For technical information,see

    page 17-29

    Frame type: H125TC,H125TD,

    H125TN

    Description:

    Hager moulded case circuitbreaker provides various

    options and wide choice for

    the contractor, switch-board

    manufacturer and distributor.

    Technical parameter:

    Complies with IEC 60947-2

    standard

    Ultimate rated short-circuit

    breaking capacityFrame 400V AC

    H125TC 18kA

    H125TD 25kA

    H125TN 35kA

    HDC series MCCB 125A frame accessory

    4 pcs (3 poles)/6 pcs (4 poles)

    HDCCATAL STMF.indd 13 1/23/04 12:14:41 PM

  • 7/28/2019 305 MCCB Hager Range

    15/34

    14

    HDC Series MCCB 250A Frame

    Frame type: H250TC,H250TD

    Description:

    Hager moulded case circuit

    breaker provides variousoptions and wide choice for

    the contractor, switch-board

    manufacturer and distributor.

    H250TC

    Icu : 25 kA

    Ue : 380/400 V AC

    Ui : 690 V

    125 A

    160 A

    200 A

    225 A

    250 A

    1

    1

    1

    1

    1

    HHB125A

    HHB160A

    HHB200A

    HHB225A

    HHB250A

    H250TD

    Icu : 35 kA

    Ue : 380/400 V AC

    Ui : 690 V

    24 V DC

    24 V AC

    110 V AC

    230 V AC

    400 V AC

    HXB006A

    HXB001A

    HXB003A

    HXB004A

    HXB005A

    230 V AC

    400 V AC

    HXB014A

    HXB015A

    2NO + 2NC

    1NO + 1NC

    1NO + 1NC / 1NO + 1NC

    HXB021A

    HXB024A

    HXB023A

    HXB031A

    HXB032A

    HYB020A

    HYB031A

    HYB041A

    HXB041A

    HXB042A

    24 V DC

    110 V AC/DC 220 V AC/DC

    HXB006A

    HXB001A

    HXB003A

    HXB004A

    HXB005A

    HXB014A

    HXB015A

    HXB021A

    HXB024A

    HXB023A

    HXB031A

    HXB032A

    HXB041A

    HXB042A

    HYB019A

    HYB030A

    HYB040A

    HHB126A

    HHB161A

    HHB201A

    HHB226A

    HHB251A

    HNB125AHNB160A

    HNB200A

    HNB225A

    HNB250A

    HNB126AHNB161A

    HNB201A

    HNB226A

    HNB251A

    Extended bus bar 6 pcs (3 poles)/8 pcs (4 poles) HYB013AHYB010A

    86

    104

    Technical parameter:

    Complies with IEC 60947-2

    standard

    Ult imate rated short-ci rcui t

    breaking capacityFrame 400V AC

    H250TC 25kA

    H250TD 35kA

    HYB019A

    HDC series MCCB 250A frame accessory

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    125 A

    160 A

    200 A

    225 A

    250 A

    1

    1

    1

    1

    1

    HXB031A

    1

    HYB010A

    N

    For technical information,see

    page 17-29

    Designation Current

    Rating(A)

    Ref.No.

    4 pole

    Ref.No.

    3 pole

    Pack

    Qty

    Designation Ref.No.

    4 pole

    Ref.No.

    3 pole

    Characteristics Pack

    Qty

    Installation

    location.

    Shunt trip

    Undervoltage trip

    Auxiliary switch

    Alarm switch

    Auxiliary/Aalarm switch

    Rotary handle Selectable rotary handle accessory EH1/EH2

    Selectable rotary handle accessory EH1/EH2

    Interphase barrier

    Rear connection Fixed type

    Plug-in type

    Motor mechanism

    HNB251A

    4 pcs (3 ploes)/8 pcs (4 poles)

    HDCCATAL STMF.indd 14 1/23/04 12:14:49 PM

  • 7/28/2019 305 MCCB Hager Range

    16/34

    15

    Frame type: H400TN

    Description:

    Hager moulded case circuit

    breaker provides variousoptions and wide choice for

    the contractor, switch-board

    manufacturer and distributor.

    H400TN

    Icu : 50 kA

    Ue : 380/400 V AC

    Ui : 690 V

    250 A

    320 A

    400 A

    1

    1

    1

    HNC250A

    HNC320A

    HNC400A

    24 V DC

    24 V AC110 V AC

    230 V AC

    400 V AC

    HXC006A

    HXC001AHXC003A

    HXC004A

    HXC005A

    230 V AC

    400 V AC

    HXC014A

    HXC015A

    2NO + 2NC

    1NO + 1NC

    1NO + 1NC / 1NO + 1NC

    HXC021A

    HXC024A

    HXC023A

    HXC031A

    HXC032A

    HYC020A

    HYC031A

    HYC041A

    HXC041AHXC042A

    HXC043A

    24 V DC

    110 V AC/DC

    220 V AC/DC

    HXC006A

    HXC001AHXC003A

    HXC004A

    HXC005A

    HXC014A

    HXC015A

    HXC021A

    HXC024A

    HXC023A

    HXC031A

    HXC032A

    HXC041AHXC042A

    HXC043A

    HYC019A

    HYC030A

    HYC040A

    HNC251A

    HNC321A

    HNC401A

    HYC013AHYC010A

    Draw-out device Front connecting lineHorizontal

    connecting lineVertical

    connecting line

    HYC043A

    HYC046A

    HYC047A

    HYC042A

    HYC044A

    HYC045A

    Technical parameter:

    Complies with IEC 60947-2

    standard

    Ult imate rated short-ci rcui t

    breaking capacity

    131

    697

    103

    5

    5

    47

    Frame 400VAC

    H400TN 50kA

    HXC015A

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    HNC400A

    HXC023A

    HXC004A

    Designation Ref.No.

    4 pole

    Ref.No.

    3 pole

    Characteristics Pack

    Qty

    Installation

    location.

    HDC series MCCB 400A frame accessory

    HDC Series MCCB 400A Frame

    For technical information,see

    page 17-29

    Designation Current

    Rating(A)

    Ref.No.

    4 pole

    Ref.No.

    3 pole

    Pack

    Qty

    Extended bus bar 6 pcs (3 poles)/8 pcs (4 poles)

    Shunt trip

    Undervoltage trip

    Auxiliary switch

    Alarm switch

    Auxiliary/Aalarm switch

    Rotary handle Selectable rotary handle accessory EH1/EH2

    Selectable rotary handle accessory EH1/EH2

    Interphase barrier

    Rear connection Fixed type

    Plug-in type

    Motor mechanism

    4 pcs (3 poles)/6 pcs (4 poles)

    HDCCATAL STMF.indd 15 1/23/04 12:15:00 PM

  • 7/28/2019 305 MCCB Hager Range

    17/34

    16

    Frame type: H800TN

    Description:

    Hager moulded case circuit

    breaker provides variousoptions and wide choice for

    the contractor, switch-board

    manufacturer and distributor.

    H800TN

    Icu : 50 kA

    Ue : 380/400 V ~

    Ui : 690 V

    500 A

    630 A

    800 A

    1

    1

    1

    HND500A

    HND630A

    HND800A

    24 V DC

    24 V AC

    110 V AC

    230 V AC

    400 V AC

    HXD006A

    HXD001A

    HXD003A

    HXD004A

    HXD005A

    230 V AC

    400 V AC

    HXD014A

    HXD015A

    2NO + 2NC

    1NO + 1NC

    1NO + 1NC / 1NO + 1NC

    HXD021A

    HXD024A

    HXD023A

    HXD031A

    HXD032A

    HYD020A

    HYD031A

    HYD041A

    HXD041A

    HXD042A

    HXD043A

    24 V -

    110 V AC/DC

    220 V AC/DC

    HXD006A

    HXD001A

    HXD003A

    HXD004A

    HXD005A

    HXD014A

    HXD015A

    HXD021A

    HXD024A

    HXD023A

    HXD031A

    HXD032A

    HXD041A

    HXD042A

    HXD043A

    HYD019A

    HYD030A

    HYD040A

    HYD013AHYD010A

    HYD043A

    HYD046A

    HYD047A

    HYD042A

    HYD044A

    HYD045A

    HND501A

    HND631A

    HND801A

    Technical parameter:

    Complies with IEC 60947-2

    standard

    Ult imate rated short-ci rcui t

    breaking capacity

    7.5

    32

    103

    6

    34 8

    14580.5

    8

    57

    45

    capacity IcuFrame 400V AC

    H800TN 50kA

    HYD040A

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    1

    Note: For 800A frame, only rated current 800A is equipped with outgoing bus bar (refer to picture left).

    HND800A

    HYD030A

    HXD042A

    HDC Series MCCB 800A Frame

    For technical information,see

    page 17-29

    Designation Current

    Rating(A)

    Ref.No.

    4 pole

    Ref.No.

    3 pole

    Pack

    Qty

    HDC series MCCB 800A frame accessory

    Designation Ref.No.

    4 pole

    Ref.No.

    3 pole

    Characteristics Pack

    Qty

    Installation

    location.

    Draw-out device Front connecting l ineHorizontal

    connecting lineVertical

    connecting line

    Extended bus bar 6 pcs (3 poles)/8 pcs (4 poles)

    Shunt trip

    Undervoltage trip

    Auxiliary switch

    Alarm switch

    Auxiliary/Aalarm switch

    Rotary handle Selectable rotary handle accessory EH1/EH2

    Selectable rotary handle accessory EH1/EH2

    Interphase barrier 4 pcs (3 poles)/6 pcs (4 poles)

    Rear connection Fixed type

    Plug-in type

    Motor mechanism

    HDCCATAL STMF.indd 16 1/23/04 12:15:13 PM

  • 7/28/2019 305 MCCB Hager Range

    18/34

    17

    Technical Data

    20 Product description of HDC series MCCB

    21 Product referencing

    24 Dimension

    25 Characteristic curve

    27 Accessories

    HDCCATAL STMF.indd 17 1/23/04 12:15:13 PM

  • 7/28/2019 305 MCCB Hager Range

    19/34

    18

    Product Description of HDC Series MCCB

    a d

    aa

    bb b

    c

    Frame size

    Model frame

    Number of poles

    Rated current (A)

    Rated ambient temperature 400

    Rated insulation voltage Ui (V)

    Rated ultimate breaking capacity Icu (kA)

    IEC60947-2EN 60947-2 400 V AC

    External dimension (mm)

    Weight (kg)

    Standard function and characteristic

    Trip Mechanism

    Test button

    Manual safety device (OFF-Lock)

    *Only applicable for HXA/B/C/D033

    Connection

    method

    Life

    Front connection

    125A 250A 400A 800A

    h125tc, h125td, h125tn h250tc, h250td h400tn h800tn

    3 4 3 4 3 4 3 4

    16,20,25,32,

    40,50,63,80,

    100,125

    125,160,

    200,225,250

    250

    320

    400

    500

    630

    800

    690 V AC

    Icu / Ics

    18 / 1425 / 1935 / 25

    690 V AC 690 V AC 690 V AC

    25 / 1935 / 25

    50 / 35 50 / 35

    Icu / Ics Icu / Ics Icu / Ics

    a

    b

    c

    d

    aa

    bb

    155 165 260 273

    86 86 103 103

    104 104 130 145

    30 35 45 70

    132 126 214 243

    90 120 105 140 140 173 210 279

    1.4 1.9 1.8 2.4 5.3 7 9.4 12.5

    Thermal-magnetic Thermal-magnetic Thermal-magnetic (adjustable)

    8000 6000 3000 2500

    10000 8000 6000 6000

    Right

    : Applicable (purchase additionally) : Not applicable

    Thermal-magnetic (adjustable)

    Rear connection

    Plug-in type

    Draw-out type

    The following device can be installed additionally

    Inte

    rnal

    acc

    essory

    External

    accessory

    Shunt trip SHT

    Undervoltage trip UVT

    Auxiliary switch AUX

    Alarm switch ALM

    Auxiliary alarm switch AUX+ALM

    Motor mechanism

    Rotary handle

    Interphase barrier

    Extended bus bar

    Electrical endurance (no. of operation)

    Mechanical endurance (no. of operation)

    Right

    Right

    Right

    Right

    RightRight

    Right

    Right

    Left

    Left, right

    Left, right

    Left, right

    LeftLeft

    Left

    Left

    Left, right

    Left

    Left

    HDCCATAL STMF.indd 18 1/23/04 12:15:16 PM

  • 7/28/2019 305 MCCB Hager Range

    20/34

    19

    Product Referencing of HDC Series MCCB

    Product referencing of MCCB

    1. Main product number

    2. Product category&breaking capacity

    D=16-18kA moulded case circuit breaker

    H=25kA moulded case circuit breaker

    N=35-50kA moulded case circuit breaker

    X=auxiliary device

    Y=accessory3. Frame type

    A = 125 frame

    B = 250 frame

    C = 400 frame

    D = 800 frame

    4. Rated current

    3 poles 4 poles

    16A=016 017

    20A=020 021

    25A=025 026

    32A=032 033

    40A=040 041

    50A=050 051

    63A=063 064

    80A=080 081

    5. Serial

    A=International

    Note: If accessory is ordered with moulded case circuit breaker together, please fill in moulded case circuit breaker number and accessorynumber instead of product number on order sheet. If accessory is ordered individually, then only fill in accessory number. For example, to order125 frame 16A, 35kA and operating rotary handle device with central regulating crank structure, the product reference is HNA016D / HX031-EH1. if accessory is ordered individually, then it should be HX031-EH1.

    SHT (shunt trip)

    Shunt trip is used to switch off the

    MCCB from a remote distance

    Instantaneous mechanism

    Operation characteristic (see table 1)

    UVT (undervoltage trip)

    Undervoltage trip is used to provide undervoltage

    protection for circuit and electrical devices

    Undervoltage trip can be used as remote tripping

    operation

    Characteristic (see table 2)

    Shunt Trip SHT, Undervoltage Trip UVT

    1. Main product number

    Shunt trip (table 1)

    Undervoltage trip (table 2)

    Electrical accessory

    Operating voltage range

    Rated voltage

    Electrical accessory

    Operating voltage range

    Guaranteed switch-on voltage

    Guaranteed switch-off voltage

    Shunt trip

    (0.7-1.1)xUn

    24VAC

    (0.35-0.7)xUe

    (0.85-1.17)xUe

    0.35-Ue

    24VDC

    110VAC 230VAC 400VAC

    230VAC 400VAC

    H

    H

    2. Auxiliary device

    3. Frame type

    A = 125 frame

    B = 250 frame

    C = 400 frame

    D = 800 frame

    4. Voltage used

    Shunt release: 006=24VDC001=24VAC

    003=110VAC

    004=230VAC

    005=400VAC

    Undervoltage release:

    014=230VAC below

    015=400VAC below

    5. Serial

    A=International

    X

    3 poles 4 poles

    100A=100 101

    125A=125 126

    160A=160 161

    200A=200 201

    225A=225 226

    250A=225 251

    320A=320 321

    400A=400 401

    500A=500 501

    630A=630 631

    800A=800 801

    HDCCATAL STMF.indd 19 1/23/04 12:15:17 PM

  • 7/28/2019 305 MCCB Hager Range

    21/34

    20

    Product Referencing of HDC Series MCCB

    AUX auxiliary switch, ALM alarm switch, AUX+ALM auxiliary/alarm switch

    1. Main product number

    3. Frame type

    A = 125 frame

    B = 250 frame

    C = 400 frame

    D = 800 frame

    4. Accessory type

    021=Auxiliary switch

    023=Alarm switch

    024=Auxiliary/alarm switch

    5. Serial

    A=International

    Auxiliary switch, alarm switch and auxiliary/alarm switchAuxilia ry switch is used as signal indicat ion for ON and OFFstatus of the MCCB.Alarm switch is used to send an alarm in case when the MCCBtripped on overload, short-circuit or via the shunt trip/under-voltagerelease operation.

    H

    1. Main product number

    3. Frame type

    C = 400 frame

    D = 800 frame

    4. Connection method

    042: 3 poles front connecting line

    043: 4 poles front connecting line

    044: 3 poles horizontal connecting line

    045: 3 poles vertical connecting line

    046: 4 poles horizontal connecting line

    047: 4 poles vertical connecting line

    H

    2. Auxiliary device

    2. Accessory

    Frame Size

    125A, 250A, 400A, 800A

    Rated Current of Switch

    3A

    Operating Voltage Ue

    0.3A~0.4A 0.14~0.15A

    380VAC 220VAC 220VDC 110VDC

    1. Main product number

    4. Rated voltage

    041: DC 24V

    * 042: 110V AC/DC

    043: 220V AC/DC

    H

    Motor mechanism

    2. Auxiliary device

    *For 125 frame and 250 frame, 042 means rated voltage of 110V AC/DC and 220V AC/DC.

    Draw-out device

    Auxilia ry/alarm switch combines funct ion of auxilia ry switch andalarm switch.

    switch, please see product description.

    X

    X

    3. Frame type

    A = 125 frame

    B = 250 frame

    C = 400 frame

    D = 800 frame

    5. SerialA=International

    5. Serial

    A=International

    HDCCATAL STMF.indd 20 1/23/04 12:15:18 PM

    For detailed information of available auxiliary switch and alarm

  • 7/28/2019 305 MCCB Hager Range

    22/34

    21

    1. Main product number

    H

    2. Auxiliary device

    3. Frame type

    A = 125 frame

    B = 250 frame

    C = 400 frame

    D = 800 frame

    4. Accessory type

    031 = Circular panel rotary handle device

    032 = Rectangular panel rotary handle device

    033 = Rectangular panel rotary handle device

    (high protection)

    5. Rotary handle accessory

    EH1= Centered regulating

    crank structure

    EH2=Eccentric connecting rod

    structure

    X

    1. Main product number

    4. Connection type

    030: 3 poles fixed type

    040: 3 poles plug-in type

    031: 4 poles fixed type

    041: 4 poles plug-in type

    H

    2. Accessory

    1. Main product number

    4. Rated voltage

    041: DC 24V

    * 042: 110V AC/DC

    043: 220V AC/DC

    H

    Extended bus bar

    2. Accessory

    Rear connection

    Y

    Y

    3. Frame type

    B = 250 frame

    C = 400 frame

    D = 800 frame

    1. Main product number

    4. No. of poles

    019: 3P

    020: 4P

    H

    Interphase barrier

    2. Accessory

    Y

    3. Frame type

    A = 125 frame

    B = 250 frame

    C = 400 frame

    D = 800 frame

    Product Referencing of HDC Series MCCB

    3. Frame type

    A = 125 frame

    B = 250 frame

    C = 400 frame

    D = 800 frame

    A

    5. Serial

    A=International

    5. Serial

    A=International

    5. Serial

    A=International

    Rotary handle

    HDCCATAL STMF.indd 21 1/23/04 12:15:19 PM

  • 7/28/2019 305 MCCB Hager Range

    23/34

    22

    Dimension of HDC Series MCCB

    125A frame

    Front cut-out size 3 poles

    55

    28

    R1

    132

    155

    90

    30

    M4X0.7

    Fixed Screw

    N

    132

    155

    120

    60

    102

    86

    104

    52

    28

    R2

    165

    126

    M4X0.7Fixed Screw

    35

    105

    165

    126

    70

    140

    86

    104

    R2

    92

    64

    M6X0.7Fixed Screw

    260

    140

    45

    131

    129

    108

    106

    260

    173

    135

    45

    131

    129

    108

    106

    N

    45

    131

    6

    97103

    55

    47

    92

    64

    M8X0.7Fixed Screw

    141

    70

    210

    132

    80

    70

    80

    40

    126

    117

    70 70

    141

    279

    132

    80

    80

    126

    117

    7.5

    32

    103

    6

    348

    14580.5

    8

    57

    45

    4 poles Lateral face

    250A frame

    Front cut-out size 3 poles 4 poles Lateral face

    400A frame

    Front cut-out size 3 poles 4 poles Lateral face

    800A frame

    Front cut-out size 3 poles 4 poles Lateral face

    HDCCATAL STMF.indd 22 1/23/04 12:15:29 PM

  • 7/28/2019 305 MCCB Hager Range

    24/34

    23

    Characteristic Curve of HDC Series MCCB

    16

    20

    32

    40

    50

    60

    80

    100

    125

    208 42

    260 52416 83

    520 104

    650 130

    819 164

    975 195

    1300 260

    1625 325

    125160

    200

    225

    250

    1594 281

    2040 360

    2550 450

    2869 5063188 563

    125A release curve 250A release curve

    400A release curve 800A release curve(In:500A - 630A)

    4

    3

    2

    1504030

    20

    10

    8

    654

    3

    2

    15040

    30

    20

    10

    865

    43

    2

    10.80.60.50.4

    0.3

    0.2

    0.10.08

    0.060.050.04

    0.03

    0.02

    0.010.008

    0.0060.005

    08

    09

    001

    521

    002

    052

    003

    004

    005

    006

    007

    008

    009

    0001

    0051

    0002

    0052

    0003

    0004

    0005

    0006

    0007

    0008

    051

    DNOCES

    ETUNIM

    RUOH

    500 5000500

    X5 X10

    630 6300630

    Trip current value

    There are 5 phases that canbe adjusted within adjustablerange of electromagnet trip

    Rated current(A)

    h800t

    TrippingTime

    % of rated current in comparison

    Trip current value(A) (x10)

    Min

    Max

    4000400

    Trip current value

    3200320

    2500250

    400

    250

    320

    0.010.008

    0.0060.005

    0.10.080.060.05

    0.03

    0.02

    0.04

    0.80.60.50.40.3

    0.2

    NOCES

    D

    1

    10

    2

    43

    8

    56

    504030

    20

    1

    2

    10

    ETUNIM

    4

    3

    56

    8

    4030

    50

    RU

    OH

    1

    3

    2

    4

    20

    09

    08 01

    021

    551

    002

    052

    003

    004

    005

    006

    007

    0 0001

    09

    008

    0 0051

    0052

    0002

    0003

    0004

    0005

    0008

    0007

    0006

    Min

    LO HI There are 5 phases that canbe adjusted within adjustablerange of electromagnet trip

    Rated current(A)

    h400tn

    Max

    TrippingTime

    % of rated current in comparison

    Trip current value(A)

    16A~32A Max

    40A~125A Max

    20A~32A Min

    40A~125A Min

    Trip current value

    Rated current(A) Trip Current (A)

    Trip current value

    Rated current(A) Trip Current (A)

    TrippingTime

    TrippingTime

    % of rated current in comparison % of rated current in comparison

    HDCCATAL STMF.indd 23 1/23/04 12:15:33 PM

  • 7/28/2019 305 MCCB Hager Range

    25/34

    24

    125A frame Temperaturecompensation curve

    Standardambienttemperature

    16A,20A,40A,80A

    32A,100A,125A

    63A

    130

    125

    120

    115

    110

    105

    100

    90

    0 10 20 30 40 50 60

    Ratedcurrent(%)

    Ambient tem erature CO

    125A,160A,200A

    225A,250A

    130

    125

    120

    115

    110

    105

    100

    90

    0 10 20 30 40 50 60

    Standardambienttemperature

    Ratedcurrent(%)

    Ambient temperature( C)O

    0 10 20

    90

    100

    110

    120

    130

    30 40 50 60

    320,400A

    250A

    Standardambienttemperature

    Ratedcurrent(%)

    Ambient temperature( C)O

    630A

    10

    90

    0

    100

    4020 30 50 60

    )110

    120

    130

    500A Standardambienttemperature

    Ratedcurrent(%)

    Ambient temperature( C)O

    0 10

    90

    100

    110

    800A

    20 30 40 50 60

    120

    130

    Standardambienttemperature

    Ratedcurrent(%)

    Ambient temperature( C)O

    800A release curve(In:800A)

    001

    0.0060.005

    08

    09

    0.03

    0.008

    0.01

    0.02

    0.060.05

    0.04

    0.1

    0.08

    4

    40

    0.5

    0.2

    0.4

    0.3

    DNOCES

    1

    0.8

    0.6

    2

    10

    4

    3

    8

    65

    20

    30

    3

    1

    50

    2

    ETUNIM

    654

    10

    8

    20

    50

    40

    30

    RUOH

    2

    1

    3

    X10X5

    008

    003

    521

    051

    002

    052

    005

    004

    006

    007

    0001

    009

    0051

    0002

    0004

    0052

    0003

    0005

    0006

    0007

    0008

    800 8000800

    Trip current value

    There are 5 phases that canbe adjusted within adjustablerange of electromagnet trip

    Rated current(A)

    h800t

    TrippingTime

    % of rated current in comparison

    Trip current value(A) (x10)

    Min

    Max

    Characteristic Curve of HDC Series MCCB

    250A frame Temperaturecompensation curve

    400A frame Temperaturecompensation curve

    800A frame Temperature

    compensation curve(In:500A - 630A)

    800A frame Temperature

    compensation curve(In:800A)

    HDCCATAL STMF.indd 24 1/23/04 12:15:35 PM

  • 7/28/2019 305 MCCB Hager Range

    26/34

    25

    HDC Series MCCB Accessory

    42

    65

    65

    4.5

    200

    45

    53

    36

    2- 5.50200

    61

    H

    93

    93

    H

    Ref. No.

    HXA031A

    HXB031A

    HXC031A

    HXD031A

    H

    65

    65

    95

    95

    H

    65

    65

    95

    95

    HXA032A

    HXB032A

    HXC032A

    HXD032A

    OFF position can be installed with

    padlocking device (applicable for HX*033)

    Optional accessory

    Standard configured with EH1 rotary handle

    device

    HXC031

    HXC032

    Install on distribution

    enclosure door

    Protection level:

    HX*031/HX*032 IP30

    HX*033 IP65

    Rotary handle

    Ref. No.

    HDCCATAL STMF.indd 25 1/23/04 12:15:36 PM

  • 7/28/2019 305 MCCB Hager Range

    27/34

    26

    Frame

    125A

    250A

    400A

    800A

    H

    56

    57

    62

    73

    125A

    250A400A

    800A

    H A B

    46

    4655

    55

    42

    4268

    67

    11.5

    11.515

    15

    EH1 rotary handle accessory

    Centered regulating crank

    mechanism, using plastic roller

    belt

    Breaker handle is easy tooperate, with less friction force.

    Reset indication is accurate and

    flexible, with long service life

    Y

    Y

    X X

    H

    20

    24

    D

    MIN = 50mm

    H

    16

    24

    D

    MIN = 50mm

    Y

    B

    X

    A

    YA

    X

    X

    Y

    B

    H

    16

    24

    D

    MIN = 50mm

    EH2

    EH1

    HDC Series MCCB Accessory

    Rotary handle With guide orientationto prevent misoperation or

    overhead operation which may

    cause breaker handle broken

    High reliabilityOne device with three handles

    available to select

    EH2 rotary handle

    Accessory adopts eccentric

    type connecting rod mechanism,

    save space

    One device with three handlesavailable to select

    Frame

    HDCCATAL STMF.indd 26 1/23/04 12:15:40 PM

  • 7/28/2019 305 MCCB Hager Range

    28/34

    27

    Compact structure, small

    size, easy to install, capable of

    manual operation. The product

    adopts advanced switch power

    technology, its mechanicaland electrical life ensures high

    reliability.

    Both AC/DC power can be

    used, with wide voltage control

    range and small working current

    With colored sign (red, green

    and white) to indicate ON, OFF

    125A Frame

    Ref. No.

    HXA041A

    A

    HXA042A

    B C d E H Mechanical life(times)

    30 132 90 4.5 116 89.5 14000

    HXB041A

    A

    HXB042A

    B C d E H

    35 143 90 4.5 116 93 10000

    HXC041A

    A

    HXC042A

    B C d E H1

    45 213 130 6.5 176 129 5000

    HXD041A

    HXD042A 800A Frame

    CH1

    H2

    A

    P1 P2 S1 S2 S4

    ON OFF

    SRZHU

    Uc

    4-d

    E lec tric dr iv in gmechani sm

    B

    EWarning

    1.It should be operated with 180 in clockwise directionwhen performing manual operation.Anti clock wise op-erationis prohibited.2.Whendoing pressure resistance test:place betweenline entry terminal P1 & P2 (exclude S1, S2 andS4) ofpower supply andinstallation bolt of electric operationcan resist AC 50Hz, 1500V power frequency pressureresistance test.3.When rated voltage of electric operationis DC24V,pressure resistance test is not allowed.

    Manual operation handle

    H

    E

    A

    4-d

    P1 P2 S1 S2 S4

    C

    BB

    ON OFFUc

    Warning1.It should be operated with 180 in clockwise directionwhen performing manual operation. Anti clock wise op-eration is prohibited.2.When doing pressure resistance test:place betweenline entry terminal P1 & P2 (exclude S1, S2 and S4) ofpower supply and installation bolt of electric operation

    can resist AC 50Hz, 1500V power frequency pressureresistance test.3.When rated voltage of electric operation is DC24V,pressure resistance test is not allowed.

    Manual operationhandle

    SRZHU

    E lec tr ic d r iv in gmechani sm

    H

    E

    A

    4-d

    P 1 P 2 S 1 S 2 S 4

    C

    BB

    ON OFFUc

    Warning1.It should be operated with 180 in clockwise directionwhen performing manual operation. Anti clock wise op-eration is prohibited.2.When doing pressure resistance test:place betweenline entry terminal P1 & P2 (exclude S1, S2 and S4) ofpower supply and installation bolt of electric operationcan resist AC 50Hz, 1500V power frequency pressureresistance test.3.When rated voltage of electric operation is DC24V,pressure resistance test is not allowed.

    Manual operation handle

    SRZHU

    E lec tr ic d r iv in gmechani sm

    Motor mechanism

    70 243 130 0.2 176 146 5000

    H2

    129

    136.5

    HXC043A

    HXD043A

    125A Frame

    400A & 800A Frame

    HDC Series MCCB Accessory

    and TRIPPED

    status

    250A Frame

    Applicablebreaker

    250A Frame

    Ref. No. Mechanical life(times)

    400A Frame

    Ref. No. Mechanical life(times)Applicable

    breaker

    Applicablebreaker

    HDCCATAL STMF.indd 27 1/23/04 12:15:43 PM

  • 7/28/2019 305 MCCB Hager Range

    29/34

    28

    Draw-out

    device

    This device adopts lever

    principle. With push handle, easy

    to insert and pull out.

    Main circuit and secondary

    circuit can be connected ordisconnected

    With safe and reliable interlock

    function. When MCCB is not

    installed properly in draw-out

    device, breaker is unable to

    switch on.

    When breaker is pulled out from

    draw-out device, MCCB will

    automatically trip and cut off

    power supply.

    With temporary isolation andclear isolation function. When

    MCCB is drawn-out, there is

    grounding bolt installed on

    side board to prevent electrical

    leakage.

    3P

    4P

    Pole

    303

    303

    L1

    332

    332

    L2

    196

    196

    L3 H1

    17.5

    11

    H2

    77

    77

    H3

    44

    44

    W1

    211

    255

    W2

    253

    d1

    88

    88

    A

    11

    253 17.5

    B d2

    141

    141

    6.5

    6.5

    800A Frame

    3P

    4P

    387 410 241 1373 70 289 140238 26 131 6.5

    387 410 241 1373 70 359 140238 26 131 6.5

    3L

    H3

    H2

    H1

    Frontconnection

    Rearconnection

    2L

    1L

    d

    W1 W1

    W2

    B

    A

    23

    d

    HYC042A

    HYC044A

    HYC045A

    HYC043A

    HYC046A

    HYC047A

    HYD042A

    HYD044A

    HYD045A

    HYD043A

    HYD046A

    HYD047A

    400A Frame

    Ref. No. External dimensionApplicablebreaker

    Installation size

    HDC Series MCCB Accessory

    Three connection method: with

    characteristic of cost effective,

    safe, reliable, etc.

    HDCCATAL STMF.indd 28 1/23/04 12:15:47 PM

  • 7/28/2019 305 MCCB Hager Range

    30/34

    29

    Rear connection Rear connection used formoulded case circuit breaker

    enhances isolation function

    between MCCB and main circuit.

    It has the characteristic of easyinstallation, reliable

    External dimension (mm) and installation size of rear connection (fixed type)

    HYA030A

    HYB030A

    HYC030A

    HYD030A

    125A Frame

    250A Frame

    92

    108

    146

    205

    A

    60

    70

    88

    178

    A1

    30

    38

    52

    45

    B

    70

    74

    145

    158

    B1

    102

    108

    177

    198

    C D

    -

    10

    D1

    134

    145

    227

    243

    E

    M10

    25

    28

    44

    F

    13

    13

    18.5

    57

    G

    26

    34

    37

    43

    H

    16

    15

    20

    20

    H1

    M10

    6

    8

    16

    J

    65

    79

    78

    88

    K1

    126

    134

    130

    148

    K2

    60

    70

    88

    140

    L

    M5

    M5

    M8

    M8

    M

    13

    13

    6

    10

    10

    6

    1K

    2K

    D1

    F

    B

    B

    C

    L

    A

    D A1

    1B

    E

    J

    M

    H1

    HG

    HYA031A

    HYB031A

    HYC031A

    HYD031A

    122 90 30 70 - 134 M10 13 26 16 M10 65 126 60 M56

    143 105 38 74 145 25 13 34 15 6 79 134 105 M56

    190 132 52 145 10

    102

    108

    177

    10

    13 227 28 18.5 37 20 8 78 130 132 M8

    275 248 45 158 198 243 44 57 43 20 16 88 148 210 M81310

    3

    4

    3

    4

    3

    4

    3

    4

    HYA040A

    HYB040A

    HYC040A

    HYD040A

    92

    108

    146

    212

    A

    60

    70

    88

    140

    A1

    30

    38

    52

    57

    B

    70

    74

    145

    143

    B1

    102

    108

    177

    184

    C D

    -

    10

    D1

    134

    145

    227

    243

    E

    M10

    25

    28

    44

    F

    13

    13

    18.5

    57

    G

    26

    34

    37

    43

    H

    16

    15

    20

    20

    H1

    M10

    6

    8

    16

    J

    65

    79

    78

    129

    K1

    126

    134

    130

    -

    K2

    60

    70

    88

    140

    L

    M5

    M5

    M8

    M8

    M

    13

    13

    6

    10

    10

    6

    HYA041A

    HYB041A

    HYC041A

    HYD041A

    122 90 30 70 - 134 M10 13 26 16 M10 65 126 60 M56

    143 105 38 74 145 25 13 34 15 6 79 134 105 M56

    190 132 52 145 10

    102

    108

    177

    10

    13 227 28 18.5 37 20 8 78 130 132 M8

    282 210 57 143 184 243 44 57 43 20 16 129 - 210 M81310

    3

    4

    3

    4

    3

    4

    3

    4

    HDC Series MCCB Accessory

    contact, small insert & pull force

    and low temperature rise.

    External dimension (mm) and installation size of rear connection (plug-in type)

    Pole Ref. No.External dimensionand insallation sizeApplicable

    breaker

    Pole Ref. No.External dimension and insallation sizeApplicable

    breaker

    400A Frame

    800A Frame

    125A Frame

    250A Frame

    400A Frame

    800A Frame

    HDCCATAL STMF.indd 29 1/23/04 12:15:53 PM

  • 7/28/2019 305 MCCB Hager Range

    31/34

    30

    Notes

    HDCCATAL STMF.indd 30 1/23/04 12:15:53 PM

  • 7/28/2019 305 MCCB Hager Range

    32/34

    31

    Notes

    HDCCATAL STMF.indd 31 1/23/04 12:15:53 PM

  • 7/28/2019 305 MCCB Hager Range

    33/34

    32

    Notes

    HDCCATAL STMF.indd 32 1/23/04 12:15:53 PM

  • 7/28/2019 305 MCCB Hager Range

    34/34

    The success is in the system

    Hager Electro SAS

    132, boulevard d'EuropeB.P. 3F-67215 Obernai CedexFrance

    Tel : +(33) 3 88 49 50 50

    Fax : +(33) 3 88 49 51 44http://www.hager.com