7 troubleshooting
TRANSCRIPT
25
Start
Replace the power cord fuse
Check the connector contact
Replace TRANS (LVT)
Check diode (D1~4) or replace PCB
Repair REG1 (7812) or replace PCB
Repair REG2 (7805) or replace PCB
Check panel PCB display
Isn't the main fuse of the power cord open?
(Model with fuse)
NO
YES
YES
NO
NO
NO
NO
NO
YES
YES
YES
YES
Is the voltage of CN70 end on main
PCB normal?
Is the voltage of 2nd side of TRANS on
main PCB normal?
Is the input voltage of REG1 (7812) on main PCB normal?
Is the output voltage of REG1 (7812) on main PCB normal (12V)?
Is the output voltage of REG2 (7805) on main PCB normal (5V)?
Normal
6. TROUBLESHOOTING
6-1. When the power is not coming on
TROUBLESHOOTING
26
Start
Repair REG1 (7812) or replace PCB
Repair REG2 (7805) or replace PCB
Check connector connection
Check connecting wire Refer to circuit diagram
Repair/replace panel PCB
Check connector contact and terminal connection
Is the output voltage of REG1 (7812) on main
PCB normal (12V)?
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
Is the output voltage of REG2 (7805) on main
PCB normal (5V)?
Is the CN50 connection on main
PCB normal?
Is the wire connected between CN50 and panel PCB on
main PCB normal?
Is the connection of panel PCB connector
normal?
Is the panel PCB LED connection and pattern
connection normal?
Normal/Check set
6. TROUBLESHOOTING
6-2. When the display panel PCB is not working
27
TROUBLESHOOTING
Start
Check panel operation (Power Cool operation) Refer to panel problem repair
Recheck after selecting the key
Repair wire
Replace photosynthesis PBA
Is the PBA panel normally operating?
YES
YES
NO
NO
NO
NO
YES
YES
Is the Fresh Care Light key on PBA panel selected?
Is the connection of the CN50 (3, 4) wire of main PCB connector
to the photosynthesisLED PCB normal?
Is the photosynthesis LED PBA normal?
Normal/Recheck the set
6. TROUBLESHOOTING
6-3. When photosynthesis LED is not working
TROUBLESHOOTING
28
6. TROUBLESHOOTING
6-4. When the compressor is not working
Start
Enter forced operation
Check cold solder/replace PCB
Replace IC04/replace PCB
Replace relay/replace PCB
Replace/repair COMP
Completely insert connector/check contact
Is forced operation in progress?
YES
YES
NO
NO
NO
NO
NO
NO
YES
YES
YES
YES
Is the output of MICOM #26 "High" (5V)?
Is the #14 of IC04 "Low"?
Is the COMP relay normal?
Is the contact of connector CN71 normal? (1,5)
Is the COMP assembly normal?
Assemble wire and check connected condition
1. The compressor does not operate when 5 minutes have not passed after satisfying the temperature.2. The compressor does not operate during defrosting.3. When the freezer sensor is not connected, it detects as low temperature and the compressor does not operate.
(Except for forced operation.)
TROUBLESHOOTING
29
Start
Enter forced operation
Correct connected condition/check wire
Close door
Replace door switch
Is the COMP operating?
YES
YES
NO
NO
NO
NO
YES
YES
Is the connection with COMP end (joint) normal?
Isn't the door open? (Freezer or refrigerator)
Is the door switch normal?
Assemble wire and check connected condition
6. TROUBLESHOOTING
6-5. When the cooling fan is not working
“When checking the cooling fan, do the checking with the forced operation selected.”
1. When the COMP is turned off, the freezer cooling fan is maintained off.
2. Even when the COMP is turned on, it is always kept off when the freezer or refrigerator door is open.
30
TROUBLESHOOTING
Start
Replace lamp/ LED board
Repair contact part
Repair door switch part
Improve/repair connector contact
Is the lamp/LED board normal?
YES
YES
NO
NO
NO
NO
YES
YES
Is the contact condition of the LAMP/LED board soket
connector normal?
Is the contact part of the door switch normal?
Is the connecting contact part of connector
CN70 1, 7 normal?
Assemble wire and recheck the connected condition
6. TROUBLESHOOTING
6-6. When the refrigerator LED lamp is not working
31
TROUBLESHOOTING
Start
Is the temperature of applicable defrost sensor
-5� or below?
Maintain certain forced operation
Replace MICOM, replace PCB
Replace/repair IC03, IC06, replace PCB
When you press the forced defrost key , does
defrosting start?
YES
NO
NO
NO
YES
NO
NO
YES
YES
NO
Is the power connected to the
defrost heater?
Is MICOM #25 "High"(5V)?
Is it IC04 #13?
Replace/repair relay , replace PCB
Recheck the contact condition of connector CN71
Replace temperature fuse
Replace EV AP assembly
Is the relay (R Y72, R Y71) normal?
Refer to common relay R Y71 defrost heater R Y72 relay check
A
YES
YES
NO
NO
NO
YES
YES
Is the contactcondition connectorCN71 normal?
Is the temperature fuse within the EVAP
normal?
Is the defrost heater disconnected?
Check the wire assembly condition
6. TROUBLESHOOTING
6-7. When the defrost is not working
1. When the defrost sensor is short and defective, the defrost does not work but the normal operation continues. (As the self diagnosis check item, it is checked when the power is turn off/on again.)
2. When the temperature fuse is disconnected, the heating gets disabled, making the temperature rise naturally and delaying the COMP OFF time according to defrost to cause temperature defect.
3. When the defrost sensor is open and defective, the heating does not end and disconnects the temperature fuse to maintain the COMP OFF condition. (As the self diagnosis check item, it is checked when the power is turn off/on again.)
32
TROUBLESHOOTING
Normal
Check wire/replace defrost sensor
Repair temperature detection part, replace PCB
Is the recover after heating for a certain period of
time normal?
NO
YES
YES
NO
NO
YES
Is the temperature of defrost temperature higher than
the ending temperature?
Is the voltage of MICOM #9 entered higher than voltage
of ending temperature?
Measure applicable sensor resistance(Appendix table)
Measure applicable sensor resistance(Appendix table)
Replace PCB
A
6. TROUBLESHOOTING
6-7. When the defrost is not working
33
TROUBLESHOOTING6. TROUBLESHOOTING
6-8. In case of self diagnosis error
1) In case of freezer temperature sensor
▶Error display
Start
Replace temperature sensor
Poor connector contact/reinsertion
Check the wire disconnection between connector sensors
Check cold solder, short, solder touch
Is the single productof fridge temperature
sensor normal?
YES
YES
NO
NO
NO
NO
YES
YES
Is the inserted condition of main PCB connector
(CN50) normal?
Is the connecting wirebetween main PCB connector
(CN50) and temperature sensor(water color) normal?
Reference 12Refer to temperaturetable
Is the input voltage of MICOM PIN
#10 normal?
Replace PCB
34
TROUBLESHOOTING6. TROUBLESHOOTING
2) In case of external sensor error (Applied to type with external sensor)
▶Error display
Start
Replace external sensor
Poor connector contact/reinsertion
Check the wire disconnection between connector sensors
Check cold solder, short, solder touch
Is the single product ofdefrost sensor normal?
YES
YES
NO
NO
NO
NO
YES
YES
Is the inserted condition of main PCB connector
(CN50) normal?
Is the connecting wire betweenmain PCB connector (CN50) and defrost
sensor (water color) normal?
Reference 12Refer to temperaturetable
Is the input voltage of MICOM PIN #9 normal?
Replace main PCB