a0210-06 cerament®| · si no se reuier e brocado para lacolocacin de tornillos, la herida puede...

2
Article number Description Quantity A0210-06 CERAMENT®|BONE VOID FILLER 5mL 1 A0210-05 CERAMENT®|BONE VOID FILLER 10mL 1 A0210-10 CERAMENT®|BONE VOID FILLER 18mL 1 1 CERAMENT®|BONE VOID FILLER contains Description A0210-06 5mL A0210-05 10mL A0210-10 18mL CERAMENT®|CMI Combined mixing and injection device. Pre-filled with ceramic, biocompatible bone substitute. Valve included. 1 1 1 CERAMENT®|C-TRU Iodine based radio opacity enhancing component. Pre-filled syringe contains the exact amount. 1 1 1 CERAMENT®|ID Specially designed injection device. 1 1 2 CERAMENT®|Delivery System Tip Extender 11G x 50mm Tip Extender 11G x 100mm 1 1 1 1 1 1 PR 0419-03 en EU 2017-10 CERAMENT®|BONE VOID FILLER The next generation of bone substitute CERAMENT |BONE VOID FILLER The next generation of bone substitute BONESUPPORT AB Ideon Science Park, Scheelevägen 19 SE-223 70 Lund, Sweden T: +46 46 286 53 70 F: +46 46 286 53 71 E: [email protected] www.bonesupport.com ®

Upload: others

Post on 11-Apr-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: A0210-06 CERAMENT®| · si no se reuier e brocado para lacolocacin de tornillos, la herida puede cerrarse en ... r Rapid return to normal activities r No need for a second surgical

Article number Description Quantity

A0210-06 CERAMENT®|BONE VOID FILLER 5mL 1

A0210-05 CERAMENT®|BONE VOID FILLER 10mL 1

A0210-10 CERAMENT®|BONE VOID FILLER 18mL 1

1 CERAMENT®|BONE VOID FILLER contains

Description

A0210-06

5mL

A0210-05

10mL

A0210-10

18mL

CERAMENT®|CMI Combined mixing and injection device. Pre-filled with ceramic, biocompatible bone substitute. Valve included.

1 1 1

CERAMENT®|C-TRU Iodine based radio opacity enhancing component. Pre-filled syringe contains the exact amount.

1 1 1

CERAMENT®|ID Specially designed injection device.

1 1 2

CERAMENT®|Delivery System Tip Extender 11G x 50mm Tip Extender 11G x 100mm

1 1

1 1

1 1

PR 0419-03 en EU 2017-10

CERAMENT®|BONE VOID FILLERThe next generation of bone substitute

CERAMENT |BONE VOID FILLERThe next generation of bone substitute

BONESUPPORT ABIdeon Science Park, Scheelevägen 19 SE-223 70 Lund, Sweden

T: +46 46 286 53 70F: +46 46 286 53 71E: [email protected]

www.bonesupport.com

®

Page 2: A0210-06 CERAMENT®| · si no se reuier e brocado para lacolocacin de tornillos, la herida puede cerrarse en ... r Rapid return to normal activities r No need for a second surgical

CERAMENT |BONE VOID FILLER The next generation of bone substitute

Acetabular revision surgery utilizing CERAMENT®|BONE VOID FILLER3

ORThOpEDiCs ORThOpEDiCs

Time and use chart

3 min 5 min30s0 7 min 9 min ~15 min

Si no se requiere brocado para lacolocación de tornillos, la herida puede cerrarse en

cualquier momento despues de 10 minutos

MEZCLADO ESPERA ESPERABROCADO Y COLOCACIÓN DE TORNILLOS

FASE INYECTABLE ESPERAINICIAR MOLDEADO(1 MIN MÁX.)

3 min 5 min30s0 7 min 9 min ~15 min

If drilling & screw insertion is notrequired, the wound can be closed

anytime after 10 minutes

MIX WAIT WAITDRILLING& SCREW INSERTION

INJECT WAITINITIATEMOLDING(MAX 1 MIN)

Time and use chart

3 min 5 min30s0 7 min 9 min ~15 min

If drilling & screw insertion is not required, the wound can be closed

anytime after 10 minutes

MIX WAIT WAITDRILLING & SCREW

INSERTIONINJECT WAIT MOLD

personalizing a solution for your patients needs:

At 12 months – bone remodeling and hip mobility observed radiographically3

Pre-operative ap radiograph of tibial plateau fracture1

TRAuMA TRAuMA

THE pROBLEM THE sOLuTiON

proven rapid bone remodeling: 5,7

Healthy host bone within 6 to 12 months

injectable hydroxyapatite and a moldable putty: 4,5,6

Easy to mix and handle with enhanced radiopacity: 5,6,7 For consistent and safe handling, mix for 30 seconds in a ready-to-use closed mixing systemIsothermic, not temperature sensitive, self-setting

Intra-operative ap radiograph showing placement of CERAMENT®|BONE VOID FILLER1

At 18 months ap radiograph demonstrating excellent incorporation of CERAMENT®|BONE VOID FILLER by new bone1

Pre-operative lateral radiograph of calcaneal bone cyst2

BONE CysT BONE CysT

r Remodeling the bone defect into the patients own bone

r Rapid return to normal activities

r No need for a second surgical site

REFERENCEs:

4. The composite of hydroxyapatite and calcium sulphate: a review of preclinical evaluation and clinical applications. M Nilsson, MH Zheng, M Tägil; Expert Rev. Med. Devices 10(5), 675–684, 2013.

5. Osteotomy of Distal Radius Fracture Malunion Using a Fast Remodeling Bone Substitute Consisting of Calcium Sulphate and Calcium Phosphate; A Abramo, M Geijer, P Kopylov, M Tägil: J Biomed Mater Res Part B: Appl Biomater 92B: 281-286, 2010.

6. Cancellous Bone Defect Healing With A Novel Bi-Phasic Calcium Sulphate-Hydroyapatite Composite Injectable Bone Substitute;Voor MJ, Burden RL, Borden J, Nilsson M: Poster presentation ORS 2010 New Orleans USA.

7. A Prospective Case Series on CERAMENT®|BONE VOID FILLER: Preliminary Results of a Highly Injectable Biphasic Bone Substitute in Acute Trauma Surgery . A. Hofmann, MD., T. Nusselt MD., P.M. Rommens, MD. Centre for orthopedic and trauma surgery, University Medical Centre, Johannes Gutenberg University, Mainz, Germany. BONESUPPORT™ White Paper.

The above time chart is for guidance only, for exact timings please consult the latest instructions for use

Intra-operative percutaneous filling of bone void with CERAMENT®|BONE VOID FILLER2

24-month post-operative lateral radiograph demonstrating complete incorporation by bone2

®

REFERENCE iMAGEs REpRODuCED By KiND pERMissiON OF:

1. Dr P Desai, Lakeland Regional medical Center, Lakeland Florida USA 2. Dr L DiDomenico, Adjunct Professor, Ohio College of Podiatric Medicine ,Youngstown, Ohio , USA 3. Dr J Svacina, Bodden-Kliniken Ribnitz-Damgarten, Germany