alexa sup 6.0 release notes

16
   ALEXA Software Update Packet 6.0 Release Notes Page 1 of 16 Software Update Packet SUP 6.0 for ALEXA and ALEXA Plus Release Notes, February 29, 2012 Firmware 6.0:18052 Introduction We are proud to announce the release of our latest software update for the ARRI ALEXA camera system. This Software Update Packet (SUP) provides an important new feature (DNxHD recording on SxS PRO cards) and several improvements for both ALEXA and ALEXA Plus models, based on our own R&D as well as feedback from film and television professionals working with ALEXA cameras in the field. Continuing ARRI’s commitment to future-proofing the ALEXA camera platform and delivering lasting value to our customers, this SUP further enhances ALEXA’s versatility and usefulness.  All new ALEXA and ALEXA P lus cameras will have this SUP installed, and all existing cameras can be upgraded to this SUP. ALEXA M and ALEXA Studio cameras will have the same features from SUP 6.1 on. This document contains a detailed description of the new features and changes, a list of known issues and instructions for upgrading. Please take some time to read through this document to familiarize yourself with everything.

Upload: philippe-brelot

Post on 16-Jul-2015

1.147 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 1/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 1 of 16

Software Update Packet SUP 6.0for ALEXA and ALEXA Plus

Release Notes, February 29, 2012

Firmware 6.0:18052

Introduction

We are proud to announce the release of our latest software update for the ARRI ALEXA camera system.This Software Update Packet (SUP) provides an important new feature (DNxHD recording on SxS PROcards) and several improvements for both ALEXA and ALEXA Plus models, based on our own R&D as wellas feedback from film and television professionals working with ALEXA cameras in the field.

Continuing ARRI’s commitment to future-proofing the ALEXA camera platform and delivering lasting valueto our customers, this SUP further enhances ALEXA’s versatility and usefulness.

 All new ALEXA and ALEXA Plus cameras will have this SUP installed, and all existing cameras can beupgraded to this SUP. ALEXA M and ALEXA Studio cameras will have the same features from SUP 6.1 on.

This document contains a detailed description of the new features and changes, a list of known issues andinstructions for upgrading. Please take some time to read through this document to familiarize yourself witheverything.

Page 2: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 2/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 2 of 16

New Features Overview

SUP 6.0 is an update that enables the DNxHD license key for ALEXA and ALEXA Plus cameras. Here isan overview of the features in SUP 6.0. Each feature is described in detail further down.

New features for ALEXA and ALEXA Plus

• Enables DNxHD license (paid option)

• SMTPE color bars in REC OUT and MON OUT, 1Khz audio tone on HD-SDI outputs and headphones

• New User Button option: Display of False Color index on GUI

• New User Button option: Auto White Balance

• New User Button option: Turn Anamorphic de-squeeze on and off separately for EVF and MON OUT

• Icons in electronic viewfinder for: Smooth Mode active.

• Icons in electronic viewfinder and MON OUT for: ARRI Look File active (since SUP 5.0).

Update Recommendation

 As this update contains important new features and improves stability, we highly recommend for all ALEXAowners to update to this Software Update Packet.

Feedback

Should you encounter any issues, please email your feedback to [email protected] and our engineers willevaluate the issue and use your feedback to continuously improve the functionality and quality of thesoftware.

Downgrading

Even though we do not recommend it, it is possible to downgrade back to 5.0 from a camera that has SUP6.0 installed. Before and after the downgrade a 'reset to factory settings’ should be performed.

We do not recommend downgrading to versions lower than 4.0

Page 3: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 3/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 3 of 16

Table of Contents

Introduction 1New Features Overview ................................................................................................. 2

New features for ALEXA and ALEXA Plus .................................................................... 2Update Recommendation .............................................................................................. 2Feedback......................................................................................................................... 2Downgrading .................................................................................................................. 2New Features for ALEXA and ALEXA Plus 6Equipment/Accessories Supported ............................................................................. 6General ............................................................................................. ............................... 6Imaging ........................................................................................................................... 6Image Processing/Look Files........................................................................................ 6SxS Onboard Recording ................................................................................................ 6Outputs ........................................................................................................................... 6Inputs .............................................................................................................................. 6Electronic Viewfinder and/or MON OUT....................................................................... 6

Icon in EVF for: Smooth Mode active ............................................................................ 6Icons in EVF and MON OUT for: ARRI Look File active ............................................... 6

Metadata/Timecode .......................................................................................... .............. 6Remote Control/3D......................................................................................................... 7

Web Remote Control ..................................................................................................... 7User Interface ................................................................................................................. 7New User Button option: Auto White Balance ............................................................... 7

New User Button option: Anamorphic de-squeeze for EVF and MON OUT ................. 7 LIVE Button in PLAY screen removed ........................................................................... 7

Accessories Behavior ................................................................................................... 7Service/Manufacturing ................................................................................................... 7Known Issues 7Equipment/Accessories Supported ............................................................................. 7General ............................................................................................. ............................... 7

Voltage Low Battery Warning ........................................................................................ 7Firmware update: first boot after update fails with "starting user interface" ................... 7Firmware update: do not ignore “Update failed” messages ........................................... 7

Imaging ........................................................................................................................... 8Extreme Overexposure .................................................................................................. 8Pin Hole Effect ............................................................................................................... 8Shooting with Low Fps and Wide Open Shutter ............................................................ 8

Image Processing/Look Files........................................................................................ 8Look File is not Applied Automatically from User Setup ................................................ 8Look Files may not get applied after reboot or whenloading/unloading high speed mode .............................................................................. 8False Color Display: Looks may produce “wrong” color indications .............................. 8

SxS Recording ................................................................................................ ................ 8High Speed Debayering Artifacts .................................................................................. 8High Speed License Key when Downgrading to 4.0 ..................................................... 8 Deleting High Speed License Key in High Speed Mode ............................................... 8 Final Cut Pro 7: Final Cut Consolidate Error in Media Manager ................................... 8

Page 4: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 4/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 4 of 16

SxS Recording: "Unexpected stop recording" when loading/unloadinghigh speed mode ........................................................................................................... 8SxS Recording & Playback: Cards recorded with SUP6.0 will show error when inserted into 5.0 camera ...................................................................................... 9SxS Recording: When switching sensor speed fast and recordingimmediately: "unexpected stop recording" error ............................................................ 9SxS Recording: DNxHD White balance CC metadata column is missingin Media Composer Bin ................................................................................................. 9

SxS Playback .................................................................................................. ................ 9SxS Playback: "Playback failed" .................................................................................... 9SxS Playback: defective frames in playback ................................................................. 9SxS Playback: FALSE COLOR in SxS playback of REC 709 material givesover-saturated image ..................................................................................................... 9

Outputs ........................................................................................................................... 9Test signal: loading test signal (color bars) may take some seconds ........................... 9 Test tone: enabling test tone ......................................................................................... 9

Inputs .............................................................................................................................. 9Electronic Viewfinder and/or MON OUT....................................................................... 9

EVF/MON Out: Thin reddish line at top of EVF/MON OUT image at slowFPS with Surround View ON ......................................................................................... 9

Metadata/Timecode .......................................................................................... .............. 9LTC out on TC connector may differ from actual timecode ........................................... 9Problems with some SD Cards ...................................................................................... 9Display of COUNTER/JAM SYNC menu item ............................................................. 10Timecode int. free run is lost when running off-speed and swapping battery .............. 10Timecode: User bit settings cannot be recalled when loading a User setupbut default to 00:00:00:00 ............................................................................................ 10

Remote Control/3D....................................................................................................... 10EXT Sync Only Works Above 9 fps ............................................................................. 10EXT Sync with Asynchronous Frame Rates ................................................................ 10Recording in Master/Slave Mode with two cards with Different Capacity.................... 10Sync/SxS recording: slave recording starts delayed ................................................... 10

Wireless Remote System/LDS/LDA ............................................................................ 103D Sync/Lens Sync ..................................................................................................... 10LDS Lens Sync Focus is Asynchronous ...................................................................... 10

User Interface ............................................................................................................... 10User setups from SD card may apply incorrect sensor fps limitation .......................... 10Run beeper does not signal actual start of recording .................................................. 10Frame Lines, Look Files and LDA User Data are not Stored in User Setups .............. 10Changing Fps .............................................................................................................. 10No Frame Grabs Possible in High Speed Mode .......................................................... 11Image Compare Artifacts with Surround View On ....................................................... 11Image Grab with Identical File Name and Different File Content ................................ 11Image Compare: anamorphic de-squeeze not applied to images in compare mode .. 11Sensor FPS not restored when entering/exiting high speed ....................................... 11

Audio ............................................................................................................................. 11 Audio: embedded audio with sensor fps < REC OUT/MON OUT fpsno good with variframe flag ......................................................................................... 11 Audio: Adjusting input or output level gives distorted audio ........................................ 11

Accessories Behavior ................................................................................................. 11Lens Control: The ZMU-3A is not working when hardwired directly to the camera ..... 11

Service/Manufacturing ................................................................................................. 11Updating Instructions 12Download and Registration Process.......................................................................... 12Registration .................................................................................................................. 12

Page 5: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 5/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 5 of 16

Camera Update Procedure via SD Card ..................................................................... 12Precautions .................................................................................................................. 12Preparing the SD Card ................................................................................................ 12Performing the Update ................................................................................................ 13

Updating only the Electronic Viewfinder EVF-1 with a Computer ........................... 13

Updating the V-Mount Top and/or Back Battery Adapter with a Computer ........... 14APPENDIX A: DNxHD DATA SHEET 15Main Features ............................................................................................................... 15Advantages of MXF/DNxHD Recording...................................................................... 15ALEXA DNxHD Recording - Technical Data .............................................................. 16The ARRI AMA Plug-in ................................................................................................. 16

 

Page 6: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 6/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 6 of 16

New Features for ALEXA and ALEXA Plus

Equipment/Accessories SupportedLDD-FP update

LDD-FP now displays all shutter angles and other a parameters, when the LDD-FP carries the latestfirmware 3.01 (RC). Please check the download page http://www.arri.de/camera/digital_cameras/downloads.html for instructions to update your LDD-FP.

General

No changes

Imaging

No changes

Image Processing/Look FilesNo changes

SxS Onboard Recording

DNxHD Recording

MENU button > RECORDING > SXS CARDS > SXS RECORDING > DNxHD

Please see APPENDIX A: DNxHD Data Sheet, Page 15.

SxS Card formatting

In order to speed up card formatting and/or erasing, we do not test and measure the actual card data rateanymore. We have found that all SxS PRO cards are safely within the minimum required data rates. The

camera will, however, display the maximum achievable frame rate with the currently selected codec.

Outputs

SMTPE color bars

MENU > SYSTEM > TEST SIGNAL > COLOR BAR

SMTPE color bars are now available from REC OUT and MON OUT. 1Khz audio tone is available on HD-SDI outputs and headphones. Please note that the colors bars can not be recorded to SxS cards and arenot present on EVF, they are meant to be used to adjust external monitors.

Inputs

No changes

Electronic Viewfinder and/or MON OUT

Icon in EVF for: Smooth Mode active

Smooth mode icon will be displayed when smooth mode is activated.

Icons in EVF and MON OUT for: ARRI Look File active

Look file mode icon will be displayed when look file mode is activated.

Metadata/Timecode

No changes

Page 7: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 7/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 7 of 16

Remote Control/3D

Web Remote Control

The web remote GUI allows to control the camera. Connected with an Ethernet cable one can control via

“bonjour” (alexaXXXX.local in browser, XXXX is the serial number of the ALEXA) or via the IP (IP addressin browser) some metadata fields, like the user fields 1 and 2, also production data can be filled in.

User Interface

New User Button option: Auto White Balance

USER > EDIT

New User Button option: Anamorphic de-squeeze for EVF and MON OUT

USER > EDIT

LIVE Button in PLAY screen removed

The LIVE Button in the PLAY screen has been removed.

Accessories Behavior 

No changes

Service/Manufacturing

No changes

Known IssuesThis is a list of known issues for this particular software update packet. For a listing of answers tofrequently asked questions please visit our website athttp://www.arri.de/camera/digital_cameras/learn/alexa_faq.html.

Equipment/Accessories Supported

No known issues

General

Voltage Low Battery Warning

 ALEXA cameras may show a warning "Voltage level too low for mirror shutter" if the camera is set to > 30

fps and an on-board battery is used. When using the mirror shutter at higher frame rates an external 24Vbattery should be used.

Firmware update: first boot after update fails with "starting user interface"In rare occasions the first boot

after firmware update may fail with a black screen showing "starting user interface". If this should happenreboot the camera again.

Firmware update: do not ignore “Update failed” messagesIn rare cases “Updated failed” message may

appear on a dark red screen. You MUST retry to update the camera if this occurs.Please note that INFO > VERSION may indicate a successful update although some components of thecamera may still have an older firmware version. If in doubt about update please contact ARRI Service.

Page 8: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 8/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 8 of 16

Imaging

Extreme Overexposure

 An area that is overexposed more than eight stops above clipping can appear darker than its surroundings.

Pin Hole Effect

This effect is caused by small highlights, like a pin hole. These highlights activate only a small region of about 2x2 pixels and are reproduced under certain circumstances (like high contrast & high sharpness) bythe sensor as colored highlights. If this spot is moving slowly, it will change colors between cyan, magentaand white.

Shooting with Low Fps and Wide Open Shutter 

 ALEXA currently allows the setting of exposure times in excess of 1 second (i.e. 358° shutter at0.75fps = 1.33 seconds exposure). At those exposure times an increase in noise can be observed.To achieve optimum image quality at slow frame rates, the exposure time should be limited to 1/10

th 

of a second or shorter.

Image Processing/Look Files

Look File is not Applied Automatically from User Setup

The ARRI Look File name is not recalled by the User setup - the Look file is not loaded/applied althoughpresent in camera - the "routing" for Look files is not recalled

Look Files may not get applied after reboot or when loading/unloading high speed mode

In some rare instances the loaded Look Files may not get applied to the image paths after a reboot or whenloading/unloading high speed mode. Please check if the Look File has been applied.

False Color Display: Looks may produce “wrong” color indications

Color manipulation in Look Files may produce “wrong” exposure indications.

SxS Recording

High Speed Debayering Artifacts

While our tests have shown that the High Speed debayering delivers images with the same exposurelatitude, sensitivity, colorimetry and low noise level as Regular Speed debayering, we have also noticedthat in some saturated red and blue colors a checkerboard pattern can be visible. We are working onimproving this, and even though we consider it a minor issue, we want to be up front about it.

High Speed License Key when Downgrading to 4.0

If an ALEXA that had SUP 5.0 and a High Speed license installed is downgraded to SUP 4.0, the HighSpeed feature still remains accessible, but in an earlier, unstable condition. In this case the High Speed

function should not be used.

Deleting High Speed License Key in High Speed Mode

Do not delete High Speed license key from camera while in High Speed mode as unexpected behavior could result. Only delete High Speed license key in Regular Speed mode.

Final Cut Pro 7: Final Cut Consolidate Error in Media Manager 

In FCP 7 with ALEXA QuickTime/ProRes clips that have no audio are not recognized correctly by FCP 7because the clips are not marked as file type 'MooV' in the file structure.

SxS Recording: "Unexpected stop recording" when loading / unloading high speed mode

Pressing record or playback clip shortly after switching to high speed/regular speed could lead to

"unexpected stop recording 62" error. Although the camera already shows "standby ready" the image pathmay not be ready.

Page 9: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 9/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 9 of 16

SxS Recording & Playback: Cards recorded with SUP6.0 show error when inserted into 5.0 cameraSxS

cards that have been recorded with SUP 6.0 will show an error message "Wrong file system" when insertedinto a camera running SUP 5.0 or below and cannot be played back in camera. The material itself is fineand will not cause any problems further down the production pipeline.

SxS Recording: switching sensor speed recording immediately: "unexpected stop recording" error When

switching sensor speed fast and starting a recording immediately a "unexpected stop recording 107" error can occur. The recording is most likely to stop immediately with only black frames being recorded.

SxS Recording: DNxHD White balance CC metadata column is missing in Media Composer Bin

White balance CC values metadata column is missing in Avid Media Composer when linking file with ARRI AMA plug-in.

SxS Playback

SxS Playback: "Playback failed"In rare occasions a "Playback failed!" message can be triggered when

playing back clips in the camera. The clips nevertheless are fine for editing/post production. To clear such a"Playback failed!" message the camera has to be rebooted.

SxS Playback: defective frames in playbackIn rare occasions scrubbing through a DNxHD clip in playback

can lead to a defective frame being shown. The clip itself is fine and does not contain defective frames.

SxS Playback: FALSE COLOR in SxS playback of REC 709 material gives over-saturated image

When playing back a Rec 709 image from an SxS PRO card the resulting image is over-saturated if FALSE COLOR is turned ON and OFF again during playback. The recorded material is not affected.

Outputs

Test signal: loading test signal (color bars) may take some seconds Loading test signal (color bars) may

take some seconds until the signal is present on REC OUT andMON OUT.

Test tone: enabling test tone

Test tone can only be enabled if AUDIO > RECORD = ON, SENSOR FPS = PROJECT FPS andMENU > SYSTEM > TEST SIGNAL > COLOR BAR = ON.

Inputs

No known issues

Electronic Viewfinder and/or MON OUT

EVF/MON Out: Thin line at top of EVF/MON OUT image at slow FPS with Surround View ON A thin reddish

line can be observed at the top of the EVF-1/MON OUT image at slow fps with Surround View on. This isnot in the active image area, only at the very top edge of surround view.

Metadata/Timecode

LTC out on TC connector may differ from actual timecode

TC connector will only output a correct TC during Free Run and when sensor speed equals project speed. Also in SxS playback TC connector does not provide playback timecode.

Problems with some SD Cards

With some types of SD cards image grabs in DPX, TIFF, or ARRIRAW formats may be corrupted. Pleasetest new SD cards before using them for image grabs.

Page 10: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 10/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 10 of 16

Display of COUNTER/JAM SYNC menu item

Even though jam synching is not possible in Int TC mode, ‘Generator: Jam Sync’ is shown as an option inthe menu. This has no influence on the camera functions.

Timecode int. free run is lost when running off-speed and swapping batteryWith asynchronous recording, i.e. "Project frame rate" NOT EQUAL to "Sensor fps" and timecode set toINT FREE RUN, the timecode will be reset to 00:00:00 after reboot.

Timecode: User bit settings cannot be recalled when loading a User setup Entering user bits, saving as a

User setup and recalling the User setup does not restore the user bit settings but defaults to 00:00:00:00.If user bits are set the entries have to be re-entered manually after loading a User setup.

Remote Control/3D

EXT Sync Only Works Above 9 fps

The sensors of two cameras can only be synchronized via an EXT sync cable down to 9 fps.

EXT Sync with Asynchronous Frame Rates

If the sensor is set to a different frame rate than the HD output (REC OUT or MON OUT) a manual synctrigger (from the System > EXT Sync menu) may be required to get the HD outputs of both camerassynchronized.

Recording in Master/Slave Mode with two cards with Different Capacity

Recording on two SxS cards with Master/Slave setup and different free capacity is not possible.

Sync/SxS recording: slave recording starts delayed Although slave SxS recording starts after master 

syncing by timecode in postproduction assures matching master/slave footage.

Wireless Remote System/LDS/LDA

3D Sync/Lens Sync

3D lens sync with non-LDS lenses and different focus ring classes may have problems. Require lenses of the same focus ring class.

LDS Lens Sync Focus is Asynchronous

When trying to lens-sync two cameras focus settings may differ.

User Interface

User setups from SD card may apply incorrect sensor fps limitation

 A non-plausible sensor speed limitation may be applied in certain situations when loading a user 

setup from SD card.

Run beeper does not signal actual start of recording

Start beeper is not a accurate indication that recording is “at speed”. Check for a solid REC icon inHOME screen or status indo or a permanently lit red record LED.

Frame Lines, Look Files and LDA User Data are not Stored in User Setups

When saving the camera’s settings through MENU > USER SETUPS > SAVE CURRENT SETUP, ARRI Look Files, frame lines and Lens Data Archive user data are currently not stored.

Changing Fps

Changing Fps can briefly result in a flickering in the EVF.

Page 11: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 11/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 11 of 16

No Frame Grabs Possible in High Speed Mode

MENU > FRAME GRABS screen states "Grabbed images inherit MON OUT settings!". Frame grabs arecurrently completely disabled in High Speed mode.

Image Compare Artifacts with Surround View OnComparing an image with surround view mode switched on may show artifacts in the top surround viewarea.

Image Grab with Identical File Name and Different File Content

If a grab with the same filename but different content is loaded again the first grab will still be used inMENU > FRAME GRABS > COMPARE GRAB 2 LIVE IMAGE > COMPARE. Camera has to be repoweredto clear the internal frame store.

Image Compare: anamorphic de-squeeze not applied to images in compare mode

If trying to de-squeeze an image in compare mode only frame lines are re-scaled, image itself is not scaled.

Sensor FPS not restored when entering/exiting high speedSensor FPS in regular speed/high speed mode

is not restored as expected when entering/exiting high speed mode. The desired sensor FPS shouldalways be double-checked by the user.

Audio

 Audio: embedded audio with sensor fps < REC OUT/MON OUT fps no good with variframe flag

 ALEXA sends embedded audio even though it is not usable in situations where the sensor and project fpsis less than the HD output´s fps.

 Audio: Adjusting input or output level gives distorted audio

When adjusting audio input or output level a “clicking” noise can be heard on audio outputs. Adjustmentof audio levels cannot be done while recording. Be careful not to adjust audio levels when recording onan external device started manually (not using the SDI REMOTE).

Accessories Behavior 

Lens Control: The ZMU-3A is not working when hardwired directly to the camera

The ZMU-3A is not working when hardwired directly to the camera. When attached to a WCU3 (hardwiredor wireless) the ZMU-3A works fine.

Service/Manufacturing

No known issues

Page 12: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 12/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 12 of 16

Updating Instructions

Download and Registration ProcessYou have to register your ALEXA camera by serial number to download Software Update Packets (SUP).SUPs can then be uploaded to the camera either from an SD card (described in detail below), or from acomputer via the ALEXA Ethernet/RJ-45 Cable KC 153-S (3.00m/9.8ft, order number K2.72021.0).

Please note that SUP 6.0 is for ALEXA and ALEXA Plus only. Do not use it for ALEXA Studio.

Registration

• If you have not registered yet, go to the ALEXA downloads web page at http://www.arri.com/goto/alexa-dl.When the page loads there will be a selection of downloads. Please go to section 'ALEXA SoftwareUpdate Packet X.Y' (where ‘X.Y’ is the version number of the desired Software Upgrade Packet) and clickon 'Please -> register to get an account.' The ALEXA customer registration page will be opened.

• Fill in the relevant data and make sure to put in the serial number(s) of your camera(s) in the format of 

K1.71000.0-2xxx. Don't forget to agree to the registration terms at the end of the page

• When you hit the 'create account' button the system will send you an acknowledgement email with a linkfor the activation of your account. After following the link a welcome mail is sent to you containing thelogin credentials. Please login at http://www.arri.com/login/login.html and navigate to the downloadsagain.

• Most of the downloads, such as technical information and manuals, are available now. To access thesoftware package downloads you have to apply for the activation to be entitled to download software byclicking on '-> Apply for activation to access this file'. A pop-up window will ask you to 'Apply for activation'- please do so.

• The activation process is a manual procedure so this might take up to one workday. You will receive amail when your software download has been activated.

• Upon access of the software package download you will be asked to agree to the terms and conditions of this download. If you agree to these terms the download link is released.

Camera Update Procedure via SD Card

Using the SD card for updating is the easiest method. This method updates the ALEXA camera as well asthe Electronic Viewfinder (EVF-1), as long as the viewfinder is connected to the camera.

Precautions

Make sure the power supply of the camera is stable. The best way to achieve this is by using a mainspower supply attached to the battery socket. We strongly recommend against updating an ALEXA that ispowered through a battery.

Preparing the SD Card

• Have a FAT16 or FAT32 formatted SD-Card ready

• Create the following folder structure on the SD-Card:

- a folder named ‘ARRI’ in root of SD card

- a folder named ‘ALEXA’ inside the ‘ARRI’ folder 

- inside the ‘ALEXA’ folder should be the following folders:- Firmware- Framelines- Grabs- LDA- Licenses- LookFiles- Setups

Note: From SUP 4.0 on this can be achieved through the ‘Format + prepare SD card’ or the ‘Prepare SDcard’ command in MENU > SYSTEM > SD CARD.

Page 13: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 13/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 13 of 16

• Take the update package ‘xxx.pkg’ file and copy it to the ‘Firmware’ folder on the SD card.

Performing the Update

• Turn the camera on.

• Perform a factory reset in MENU > USER SETUPS > FACTORY RESET.

• Insert the SD card into the SD card slot of the camera. The slot is located below the display on the bottomof the camera. The direction how the SD card has to be inserted is shown on the camera housing.

• A card icon will show up in the notification area of the camera display. If not, the card is not recognized bythe camera.

• Go into the INFO screen by pressing the 'INFO' button on the camera’s right side.

• Save a camera log file onto the SD-Card by pressing 'SAVE TO SD'.

• Press the MENU button.

• Choose SYSTEM and then FIRMWARE.

• The FIRMWARE screen shows you which packet is currently installed (Current version: xxx).

•Press the jog wheel to select the update file.

• The list shows you all firmware files that are available on the SD card.

• Choose the desired packet and press the two lower outer screen buttons simultaneously to start theupdate.

• DO NOT REMOVE THE SD CARD WHILE THE PACKET IS BEING COPIED TO THE CAMERA!

• When the copy dialogue screen disappears, you can remove the SD card if desired.

• The update process will take 10 to 20 minutes. Wait until the update process has finished. This isindicated by a green screen informing you that the update process is completed.

• If the update process fails, which will be indicated by a red screen, repeat the update procedure.

• After the update, turn the camera off and on again. The camera firmware is now updated and you can usethe camera.

Please note that User Setup files cannot be used across software packet updates, i.e. a User Setup filecreated with SUP 2.1 is not compatible with SUP 3.0.

Please note that when updating from software package 1.0 to any later package, the camera’s display shows ‘Success’ for APIC, CMC, and ACOM at the end of the update process. The camera must then berebooted manually even though the screen still says ‘Update in progress – do not power off the camera!’ This is done by pressing the ON/OFF button until the camera switches off, then pressing the button again.This is not necessary anymore when updating from SUP 2.0 or later versions.

Updating only the Electronic Viewfinder EVF-1 with a Computer 

In case that the ALEXA electronic viewfinder (EVF-1) has not been updated with the camera, it is possibleto update the EVF-1 separately by using a computer.

• Download the Software Update Package and place it in a folder on your computer. For information onhow to obtain the SUP see ‘Download and Registration Process’ above.

• Connect the Ethernet port of the computer to the camera with the ALEXA Ethernet/RJ-45 Cable KC 153-S (3.00m/9.8ft, order number K2.72021.0).

• Connect the EVF-1 to the camera.

• Open a web browser on the computer and enter the following URL: http://alexaXXXX.local/update.cgi(where XXXX is the camera’s serial number) to access the update web page.

• In the ‘Camera Update’ section select the Software Update Package by clicking the ‘browse’ button andselecting the path to the downloaded package on your computer.

• Click the 'Update EVF' button in the ‘EVF Update’ section.

• You can watch the progress of the update on the screen.

•When the update is done, the last line on the screen reads successfully updated Evf. The updateis now finished even though the web browser continues to refresh the page. This is normal. Theviewfinder is up to date.

Page 14: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 14/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 14 of 16

• Depending on its software version the camera will state a ‘software error – reboot camera’ on the cameradisplay. This is normal. Please reboot the camera.

Updating the V-Mount Top and/or Back Battery Adapter with a Computer 

To update the firmware of the V-mount battery adapters please perform the following steps:• Update the camera with SUP 4.0 or later.

• Place the SUP in a folder on your computer.

• Connect the Ethernet port of the computer to the camera with the ALEXA Ethernet/RJ-45 Cable KC 153-S (3.00m/9.8ft, order number K2.72021.0).

• Attach a charged V-Mount battery to the mount.

• Open a web browser on the computer and enter the following URL: http://alexaXXXX.local/update.cgi(where XXXX is the camera’s serial number) to access the update web page.

• In the ‘Camera Update’ section select the Software Update Package by clicking the ‘browse’ button andselecting the path to the downloaded package on your computer.

• Click the 'Update VMOUNT' button in the ‘V-Mount Update’ section.

• The update will take approximately three minutes. You can watch the progress of the update on thescreen.

• If you get an error, you have an old style V-mount battery adapter, which can only be updated by ARRI inMunich.

• When the update is done, the last line on the screen reads successfully updated VMount

Adapter and the battery mount is up to date.

• If your V-mount battery adapter cannot be updated, please contact ARRI Servicehttp://www.arri.com/service.

Page 15: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 15/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 15 of 16

APPENDIX A: DNxHD DATA SHEET

Main FeaturesShoot 16:9 Avid DNxHD encoded MXF/DNxHD clips with ALEXA

- DNxHD 145 (8 bit 4:2:2) and DNxHD 220x (10 bit 4:2:2)- 4:2:2 available in both Regular and High Speed Mode- A DNxHD 10 bit 4:4:4 codec will be provided as a free update- Same naming convention as ProRes clips- Same exposure latitude, sensitivity and colorimetry as ProRes recording- Camera metadata embedded in XML clips- Camera metadata provided in clip summary Avid Log Exchange (ALE) file

Edit Avid DNxHD encoded MXF/DNxHD clips from ALEXA

- Material can be edited in Media Composer 5.5 and 6.0

- Free AMA plug-in for ARRI MXF/DNxHD (Mac and Windows 32/64 bit)- No transcoding required

Notes: 

- The 16:9 DNxHD function requires SUP 6.0 for ALEXA and ALEXA Plus, and SUP 6.1 for ALEXA Mand ALEXA Studio.

- The values in DNxHD 145 and DNxHD 220x denote the bit rate [Mbit] at 29.97 fps. As the supportedproject frame rates are 23.976, 24, 25 and 29.97 fps, the correct notation for these codecs wouldactually be Avid DNxHD 115/120/145 and DNxHD 175x/185x/220x.

Resource locations

- License key available for purchase online at http://alshop.arri.de 

- ARRI AMA plug-in available for free at http://www.arri.de/camera/digital_cameras/downloads.html - MXF DNxHD white paper at http://www.arri.de/camera/digital_cameras/downloads.html 

To ensure that our products enjoy a long and useful life we build them to the highest quality standards andcontinually develop new capabilities. After the Anamorphic De-squeeze and High Speed Mode licensekeys, DNxHD recording is the next new development, which allows the ALEXA family of cameras toexpand the product’s capabilities. While providing the same in-camera recording onto SxS PRO card aswith ProRes codecs for QuickTime based workflows, MXF/DNxHD material is natively supported by the Avid family of non linear editing systems.

The DNxHD capability is available through an online purchase of a license key at http://alshop.arri.de. Eachlicense key is coded to a particular camera and can be enabled by copying the license to an SD card andloading it into the camera. License features can also be disabled, allowing rental facilities to control, which

cameras are sent out with DNxHD recording.The DNxHD recording functionality enables the large number of Avid-based production facilities to drawgreater profit from shooting with ARRI ALEXAs. It removes the necessity of transcoding the cameramaterial for editing, which speeds up the process and effectively saves time and money during post.

Advantages of MXF/DNxHD Recording

1. MXF files are an open industry standard The Avid DNxHD codec source can be licensed free of charge, the codec is compliant to SMPTE VC-3,and MXF files are an open industry standard. Being a fully open format guarantees that MXF/DNxHDmaterial will be accessible for any MXF-aware application. This makes the codec also a very goodchoice for archiving HD material.

2. An acquisition and archiving format of choice 

 Applications in the Avid editing environment usually employ the OP-Atom format for MXF files. For acquisition and archiving, however, major broadcasting corporations around the globe rely on MXF filesin the OP1a format. Audio and video is always kept together and no data is lost if recording or data

Page 16: ALEXA SUP 6.0 Release Notes

5/13/2018 ALEXA SUP 6.0 Release Notes - slidepdf.com

http://slidepdf.com/reader/full/alexa-sup-60-release-notes 16/16

 

  ALEXA Software Update Packet 6.0 Release Notes Page 16 of 16

transfer is interrupted for any reason. ALEXA cameras deliver the DNxHD material in OP1a MXF filesstraight onto the recording media. This creates a good potential in terms of cost-savings.

3. Metadata is fully accessible The MXF file container also holds all camera metadata. This data is automatically provided in the

editor's bins in an Avid Media Composer and can be accessed with any basic text editor from an AvidLog Exchange (ALE) file that is also stored on the recording media and provides an overview of allrecorded takes.

4. Platform-independent Whether the material is edited on a Mac or a Windows system, the DNxHD codec can be read andwritten natively. ProRes material can also be accessed through a QuickTime AMA plug-in, but ProResfiles cannot be created from a Windows machine. On these systems, ProRes material needs to betranscoded to e.g. DNxHD when effects or sequences are rendered to disc, causing a slower output.

ALEXA DNxHD Recording - Technical Data

Requirements  ALEXA or ALEXA Plus with SUP 6.0 or higher (February 2012)

 ALEXA Studio or ALEXA M with SUP 6.1 or higher (April 2012)

Mode Switch Instant switch between Apple ProRes and Avid DNxHDImage Size 16:9, 1920 x 1080

Frame Rates Regular Mode (0.75 – 60 fps): DNxHD 145, DNxHD 220x (later DNxHD 444) 

High Speed Mode (60 - 120 fps): DNxHD 145, DNxHD 220x

Processing 16 bit linear internal image processing, Regular Speed and High Speed imagedebayering algorithm

Audio 2 Channels, 24bit, 48kHz

In-camera Recording 

DNxHD 115/120/145 DNxHD 175x/185x/220x

Color Coding: 8 bit 4:2:2 YCbCr 10 bit 4:2:2 YCbCr 

Data Rates at:

23.976, 24 fps 115 Mbit/s 175 Mbit/s

25 fps 120 Mbit/s  185 Mbit/s

29.97 fps 145 Mbit/s 220 Mbit/s

Recording capacity on64 GB SxS PRO cards:

24 fps 74 min 49 min

60 fps 29 min 19 min

120 fps 14 min 9 min

Application: Basic television application, if images

do not require adjustments in postproduction.

High quality TV applications requiring

color correction.

The ARRI AMA Plug-in

 ARRI provides a free Avid Media Access (AMA) plug-in for the Mac version and the 32 and 64 bit Windowsversion of Media Composer 5.5 and 6.0. The plug-in is used to link the camera material into the editorsbin(s) without creating a copy on the Avid storage. This gives the editor immediate and direct access to allclips just as if they were stored in the Avid Media Files folder. Depending on the project, the material couldbe edited right then and there. Typically, the material will be consolidated to provide OP-Atom MXF files onthe Avid Media Files folder. This is essentially a copying process since no transcoding is involved. Theoriginal image quality is fully retained. Note that ALEXA uses high quality intraframe codecs, which result inbigger files than material encoded using a lower quality interframe long-GOP codec.

Notes: All technical data is based on SUP 6.0. All data is subject to change without notice.