COMBUSTIFUME® Line Burners Page 5703
9/03
Design Considerations
To properly select the appropriate typeCOMBUSTIFUME® Line Burner to meet your specificapplication requirements, these four factors must firstbe determined:1. Percent (by volume) of oxygen remaining in air
stream to be heated2. Allowable duct static pressure drop, which is a
direct relationship to the velocity of air across theburner and/or profile plate
3. Air stream temperatures approaching anddownstream of the COMBUSTIFUME® Burner
4. Type of fuel to be fired through the burner
Oxygen content and temperature of effluent/airstream dictates how and which COMBUSTIFUME®
Line Burner must be applied. Flammability of a rawgas burner is affected by oxygen content, air streamtemperature and moisture content. Since a typicalapplication for COMBUSTIFUME® Burners wouldinvolve an air stream temperature of 700°F or higher,air streams with measured oxygen levels above 16%(by volume) will normally support combustion by araw gas burner and not require additional primarycombustion air. However, if measured oxygen contentin air stream is less than 16% or air streamtemperature is less than 500°F, a percentage ofpartial premixed gas/air may be required tosupplement the lower oxygen levels in your systemfor a complete combustion reaction to occur. Pleaserefer to the Air Stream Flammability Chart on thispage for the exact oxygen requirements of effluent/airstreams.
Elevated air stream temperatures approachinga COMBUSTIFUME® Burner can be as high as1050°F (566°C). This naturally causes changes in airdensity and net air velocities, and results in an effecton COMBUSTIFUME® Burner performance.
The combination effect of lower inlettemperature and lower oxygen levels will normallyrequire a partial percentage of premixture be addedthrough the COMBUSTIFUME® Burner system.
This combination effect (or air stream flammability)is graphically illustrated in the chart at right.
Since oxygen content within the air stream iscritical to the flammability range of aCOMBUSTIFUME® Burner, it also directly affects themaximum capacity (Btu/hr per lineal foot) of theburner assembly.
Any combination of temperatures and oxygen levelsfalling above the raw gas firing diagonal line shouldsupport combustion with a raw gas COMBUSTIFUME®
Burner system.Any combination of incoming temperature and
measured percent of oxygen falling below thediagonal line will normally require the designatedpercentage of premixing through aCOMBUSTIFUME® Burner system.
Notice: When primary combustion air issupplemented in the system, a corresponding workload increase must be factored into the grossheating requirement to heat the fresh combustionair being introduced.
Page 5704 COMBUSTIFUME® Line Burners
Performance Selection Data
GeneralAir stream velocity and resulting pressure drop
affect performance of COMBUSTIFUME® Burnersystems. This velocity across and through yourburner’s mixing plates must be kept uniform andwithin desired limits by use of a (customer fabricated)silhouette profile plate through which the burner fires.A minimum 6" profile plate should be installedsurrounding the interior duct walls at the leading edgeof your burner’s mixing plates.
Optimum design operating velocity ranges areshown in preceding pages. The most accuratereadings for velocities (in SFPM) are as measuredwith a velometer (or pitot tube) directly in the duct atthe plane of the profile plate and leading edge of yourburner’s mixing plates.
Since COMBUSTIFUME® Burner systems areinstalled in such widely diversified applications, it isoften difficult to get into the chamber/duct and profileplate area to obtain the velocity pressure readingsdescribed above. For this reason, a closeapproximation of operating velocities may be madewith a measurement of duct static pressure drop.Preferably, a static pressure test point one ductdiameter in distance upstream from the profile plateand one duct diameter length downstream will givean approximation of operating velocity across theburner.
These static pressure drops relate to velocity(in SFPM) as shown in Table 1 below.
CAUTION: Do not try to take a differential staticpressure reading from a test port at or near an elbowin the duct or chamber due to potentially erroneousreadings caused by turbulence set up within the ductat such points. Measure in a straight duct with at leastone duct diameter in length before and after theprofile opening.
For lower temperature rise applications,determine profile opening area by adding burnerdisplacement area (ft2/section) from page 5705 to netfree area of your duct:
Fan volume (SCFM)
Velocity (SFPM)
NOTE: Various duct size/profile area relationshipsmay give slightly different field site data than is shownin static pressure chart below.
Net free area of duct (ft2) =
)cw"(porderusserpcitatsotevitaler)MPFS(yticoleV:1elbaTtayticolevmaertsriaetamixorppA
)MPFS(etalpeliforprenrub0001 0051 0002 0052 0003 0053 0004
hguorhtporderusserpcitatstcuD)cw"(gninepoeliforp ]1[
1.0 2.0 4.0 6.0 9.0 2.1 6.1
pihsnoitaleraeraeliforp/ezistcudcificepsruoyhtiwyravyaM.8.0forotcafKenalprenrub/eliforpnodesaB]1[
COMBUSTIFUME® Line Burners Page 5705
9/03
Design and Application Details
COMBUSTIFUME® Line Burner Design Parameters
Thermal expansion due to the high operatingtemperature of incineration units requires specialcare in manifold and combustion chamber design.Flexible connections between manifold and burnerassembly inlets are recommended, and provisionshould be made in burner support to allow for growthwith temperature.
Flame supervision by UV scanner is preferred,and must be used whenever effluent inlet tempera-tures exceed 600°F (316°C). Cooling or purge air tothe scanner connection is recommended. Flame rodscan be mounted through pilot assembly, but arelimited to 600°F (316°C) effluent inlet temperature.
Observation and access are both important to asuccessful installation. Ability to view the flame fromdownstream of burner (particularly pilot location)greatly simplifies start-up and operating procedures,while access to upstream side of burner facilitateseventual maintenance.
Displacement area per sectionFor purposes of calculating operating air velocities
and resulting static pressure drops across the burnerassembly and profile plate, use the followingequivalent displacements:
Each 6" straight section: 0.35 ft2
Each 12" straight & 12B section: 0.7 ft2
Each 12" x 6" tee section: 0.75 ft2
Each 12" x 12" cross & BX section: 0.85 ft2
Each 36" B H section: 1.5 ft2
Maxon assumes no responsibility for the use or misuse ofthe piping layouts shown. Specific piping and wiringdiagrams should always be submitted to the appropriateagencies for approval on each application.
Minimum capacity is 150,000 Btu/hr per lineal footof COMBUSTIFUME® Line Burner for “raw gas”burner systems.
Differential gas pressure (the difference betweengas pressure inside COMBUSTIFUME® Burnermanifold and the combustion chamber static pres-sure) required in burner at maximum firing rates isshown in table below.
Effluent air streams with oxygen levels of 12%to 16% may be heated with COMBUSTIFUME®
Burner supplied with a partial premixture of air andnatural or propane gas.
A complete burner system to handle thesedifficult applications would include aCOMBUSTIFUME® Burner assembly, Series “HG”Mixing Tube, MICRO-RATIO® Control Valve and acombustion air blower as shown below. Your Maxonrepresentative can help you select from the broadrange of options available.
“HG” Mixing Tube System for partial premixed COMBUSTIFUME® Burner system
EMUFITSUBMOC ®
epyTrenruB
mumixaMerutarepmeT
stimiL
mumixaMegrahcsiD
erutarepmeT
mumixaMcitatS
erusserPporD
D4FCF°0001)C°835(
F°0051)C°618(
cw"2
D5FC cw"5.2
D5FCF°0071)C°729(
cw"2B5FC
F°0501)C°665(
levelnegyxoerehwsmaertsrianignirifsagwarroF)nrettapgnillirdeloh42rof(%61sdeecxe
yticapaCmumixaM.tflaenilreprh/utBs'0001
005 006 007 008 009 0001
saGlaitnereffiDserusserP )cwsehcni(
larutaN 2 9.2 4 2.5 6.6 8
enaporP 8.0 2.1 6.1 1.2 6.2 3.3
Page 5706 COMBUSTIFUME® Line Burners
Performance Selection Data
Series “HG” Mixing Tubes with partially premixed COMBUSTIFUME® Burnersystem in 12 – 16% oxygen level air stream applications
General Selection Procedure:1. Determine available oxygen level in
air stream to be heated.2. Enter Table 1 under column with
specific oxygen level for parametersof your application. Available oxygenlevel dictates combustion air andextra heat requirements for additionalprimary air flows.
3. Calculate gross heat requirement.4. Determine burner footage and inlet
feed requirements.5. Select “HG” Mixing Tube size from
Table 2 based upon the volume ofcombustion air required.
Example:– Required heat release of 7,000,000 Btu/hr– For system measured with 13.5% oxygen in air
stream
From Table 1 (13 to 13.9%, middle column)
A. Gross heat required7,000,000 x 1.075 = 7,525,000 Btu/hr
B. = 10.75 ft. = 11 ft. of burner
C. = 2 inlets
D. 11 ft. x 41 SCFM/ft = 451 SCFM primary air withdifferential pressure = 6.4" wc
From Table 2 (400 to 1167 SCFM)
E. Select 6" HG Mixing Tube with12 each 29/64" gas orifices per Table 3
F. Select MICRO-RATIO® Control Valve– for 451 SCFM air = (27060 SCFH)– for 7525 SCFH natural gas
7,525,000 Btu
700,000 Btu/ft
11 ft.
6 ft/inlet
sretemaraPngiseD:1elbaT
:tneulffeninegyxofotnecreP 9.21ot21 9.31ot31 9.51ot41
esaelertaehssorgniesaercnideriuqeR)rh/utB(
%01 %5.7 %5
fotooflaenilrepesaelertaehmumixaMrenrub )rh/utB(
000,007 000,000,1
esaelertaehmuminiM fotooflaenilrep)rh/utB(renrub
000,57
deriuqerrianoitsubmoC "GH"seireShguorht)renrubfotooflaenilrepMFCS(ebuTgnixiM
74 14 43
deriuqererusserprialaitnereffiD )cwsehcni(dnatelnirenrubneewtebderusaemsa
erusserpcitatsrebmahc/tcud8 4.6 5.5
noitceleSebuTgnixiM"GH"seireS:2elbaTgnixiM"GH"
eziSebuTtaderiuqeremulovrianoitsubmocMFCS
ebuTgnixiM"GH"hguorhtmumixam
"2 091ot0
"3 062ot09
"4 005ot571
"6 7611ot004
"8 0052ot088
"GH"seireSrofsgnillirDecifirOsaG:3elbaTsebuTgnixiM
erusserpsagtelniGISP2nodesabwolebsgnillirD:ETON)telnisagebuTgnixiM"GH"taderusaem(
"GH"foeziSebuTgnixiM
sagforebmun(nisecifiro
)sesehtnerap
smetsysdeximerpyllaitraproF
riAnoitsubmoCerusserP
riataderusaem"GH"fotelniebuTgnixiM
sgnillirDecifirOsaGOLFRIA"66"seireSrof ® dna
EMUFITSUBMOC ® srenruB
roflarutaN
saG
rofenaporP
saG
rofenatuB
saG
GH"2)4(
iso8&6
"46/12 I F
GH"3)6(
"46/12 I F
GH"4)8(
"61/7 T R
GH"6)21(
"46/92 "8/3 T
GH"8)21(
"46/53 "46/92 "61/7
COMBUSTIFUME® Line Burners Page 5707
10/11
Performance Selection Data
Raw gas firing of COMBUSTIFUME® Burners in air streams with 16+% oxygen levels
Profiling for higher temperature applicationsWhen calculating profile dimensions for
COMBUSTIFUME® Burner systems in applicationswith higher inlet air temperatures, greater temperaturerises, and/or variable air stream volumes, the air withelevated temperatures and densities must beconsidered.
Sample CalculationsA sample procedure for designing a raw gas
COMBUSTIFUME® Burner system for a thermal fuelincinerator (with 16+% oxygen level) is providedbelow.
General Selection Procedure1. Determine available oxygen level in air stream
to be heated.For a raw gas application, we will use 16+%oxygen level.
2. Determine the SCFM of air through theincinerator. Include any variations in this flow.
For our calculations, we will use a constantvolume air fan of 5000 SCFM.
3. Determine inlet temperature of effluent toCOMBUSTIFUME® Burner.
We will use inlet temperature of 700°F.
4. Determine outlet or discharge temperaturesfrom the incinerator.
For our example, we will design for 1500°F.
5. Determine the volume of any combustiblehydrocarbons in the effluent air stream.
We will use 20 gallons of evaporated solventper hour @ 110,000 Btu/gallon.
6. Determine available gas pressure and itsanticipated pressure drop through the controlsystem’s piping and valves.
For this example, we will use 5 PSIG naturalgas supply pressure available; 3" wc pressuredrop through control system; +3" wc staticpressure in combustion chamber; 8" wcdifferential gas pressure required to burner and14" wc gas pressure required from main gasregulator (at maximum burner firing rate).
7. Calculate maximum total heat required
Btu/hr = SCFM x “K”(from step 2) (from chart below)
Multiply SCFM of air by multiplier (K), whichcombines hypothetical available heat at 1500°Fand a 1.08 composite air heating factor to givethe value in Btu required being “gross heatingvalue” of fuel. Since multiplier (K) varies withinlet and discharge air temperature, the variousfactors are graphically shown below:
For 1300°F, 1500°F and 1700°Fdischarge temperatures
Evolvement of “K” = x 1000
Enter chart at 700°F inlet temperature line(from step 3); follow across to intersect the1500°F discharge temperature sloped line,then drop straight down to read the “K”multiplier factor of 1150.
Therefore, maximum heat input required:
Btu/hr = 5000 SCFM x 1150 = 5,750,000
CFH gas
SCFM air
Page 5708 COMBUSTIFUME® Line Burners
Performance Selection Data
Design procedure and calculation example (continued)
8. Determine the COMBUSTIFUME® Burnerfootage
Divide the maximum Btu/hr (calculated in step7) by 1,000,000 Btu/hr per lineal foot. Round-up to the nearest whole foot (if necessary).
5,750,000 Btu/hr (from step 7)
1,000,000 Btu/lineal foot
Required burner footage = 5.7 lineal feet
= (round-off to 6 lineal ft.)
9. Lay out a proposed burner assembly usingthese general guidelines:A. Use as few tee sections as possible to conform
to general shape of the combustion chamber.B. Minimize use of cross or back inlet cross
sections for general fume incinerationapplications, since they do not provide thesame degree of exposure to the flameachieved by straight or tee sections.
C. If multiple burner rows are used, they shouldbe placed on 12" centers to avoid need forbetween-the-row profile plate baffles.
D. Do not exceed 3,500,000 Btu/hr capacity forany 2" diameter end inlet flange.
E. 2" diameter back inlet flange and INCINO-PAK® inlet feed section should feed no morethan 7,000,000 Btu/hr capacity.
F. 3" diameter back inlet flange on “12B”section can feed up to a maximum of10,000,000 Btu/hr, or 8,300,000 Btu with any36BH section.
G. Keep burner assembly balanced and assymmetrical as possible around all inlet feeds.
H. Ductile iron 12" x 12" back inlet cross must notbe mated directly to another ductile iron 12" x12" back inlet cross.
NOTE: Several possible burner arrangements couldbe devised. For this example, we will propose theburner layout illustrated below:
Example: 6 lineal feet
RequiredBurner Footage
=
10. Determine total burner displacement area byadding the displacement area of all the individualsections (see page 5705)
Area displaced by this assembly:
(2) 12" x 6" tee sections @ 0.75 = 1.50 ft2
(3) 12" straight sections @ 0.7 = 2.10 ft2
Total Area = 3.60 ft2
11. Determine dimensions of profile plate openingusing these general guidelines:A. Profile opening should be 1" longer than
nominal length of burner assembly (dimensionX + 1" in the sketch below)
B. Edge of profile plate should be 6-1/2" fromcenterline of any “outside row” of castings
“Typical Configuration” Example:
Example: 6 lineal feet assembly
12. Calculate gross area of profile plate opening
Sq. ft. area = inches length x inches width
144 sq. in. / sq. ft.
If we assume a gross profile area of 13" x 61"
Gross area of opening in profile plate
= 13" x 61" = 5.51 sq. ft.
144 in2/ft2
COMBUSTIFUME® Line Burners Page 5709
Performance Selection Data
10/11
Design procedure and calculation example (continued)
13. Calculate the velocity of flow of the effluentover the burner and through profile opening
Velocity = SCFM (from step 2)
(SFPM) Profile Area – Burner Displacement(from step 12) (from step 10)
Velocity of Effluent:
SFPM = 5000 SCFM = 2645 SFPM
5.51 ft2 – 3.62 ft2
14. Check the duct static pressure drop across theburner assembly and profile plate
In Graph “B” below, check to see whether thevelocity determined in step 13 and the inleteffluent temperature (step 3) result in a pressuredrop within the shaded (acceptable) area.
Conditions in the shaded area are permissible.
12-1/2" x 60", which would increase pressure dropas follows:
Area = 12.5" x 60" = 5.21 ft2
144 in2/ft2
SFPM = 5000 = 3200
5.21 – 3.62
Pressure drop = 1.9" wc
15. Check the minimum Btu/hr per lineal footrequired
Maximum heat – Btu/hr availableBtu/hr (from step 1) from solvent
per foot = (from step 5)
Footage of burner(from step 8)
MinimumBtu/hr per ft. = 5,750,000 – (20 gal. x 110,000)
6 ft.
= 591,667
If above figure falls below 150,000 Btu/hr per ft.,burner footage must be reduced and/or a compromiseof other design parameters must be made. Ourexample is well above the 150,000 limit, so theturndown range of a standard COMBUSTIFUME®
Burner system should be adequate.
16. Select the proper type COMBUSTIFUME®
Burner from these general guidelines:Type of COMBUSTIFUME® Burner: With inlet effluent
temperature of 700°F, discharge temperature of1500°F, and a pressure drop of approximately 1.9" wcfor burner assembly selected:
Use Type CF4D COMBUSTIFUME® Burner
Optimum pressure should be in the 1 - 1.5" range.– If the pressure drop is too high, the profile
opening must be increased.– If the pressure drop is too low, the profile
opening must be reduced.NOTE: Chart is based on tight profiling. If sizeablegap is maintained around burner, pressure drop will beless than indicated in Graph “B”.
Pressure drop across burner and profile plate(refer to Graph “B”)
(2645 SFPM @ 700°F) = 1.1" wc drop
It would be better to change the opening to
EMUFITSUBMOC ®
epyTrenruB
mumixaMtelnI
erutarepmeT
mumixaMegrahcsiD
erutarepmeT
mumixaMcitatS
erusserPporD
D4FCF°0001)C°835(
F°0051)C°618(
cw"2
D5FC cw"5.2
D5FCF°0071)C°729(
"2B5FC
F°0501)C°665(
Page 5710 COMBUSTIFUME® Line Burners
Capacity/Selection Data
Based on capacity information given in this catalogsection, and within the constraints of duct size and airvolume flows, a COMBUSTIFUME® Burner assemblyis designed utilizing these available sections shown onthe following pages.
When ordering a burner assembly made up fromthese available module components, be sure to providean assembly sketch of the complete burner (as viewedfrom the back, or upstream, side), including locationsof all accessories and/or individual componentsections.
All open ends of burner assembly must beclosed off with one of the end closures or pilotassemblies shown on the following pages. Any endplate ports not used must be plugged.
Air stream velocity and resulting static pressuredrop affect performance and are achieved by means ofa silhouette profile plate within the duct.
A minimum profile plate width of 6" is requiredsurrounding all COMBUSTIFUME® Burnerassemblies.
Burner inlet feed piping must be adequate toprovide a well-distributed flow of air/gas throughout theburner assembly. Burner assembly layout should be
symmetrical and balanced with relation to inlet feedsections.
Ductile iron 12" x 12" back inlet cross must not bemated directly to another ductile iron 12" x 12" backinlet cross.
Do not exceed the capacity feed limitations shownin the table below.
Inlet flanges bolt directly to burner body casting andaccept threaded NPT piping. Chart above showsmaximum lineal feet of COMBUSTIFUME® Burner thatmay be fed by a given inlet flange.
COMBUSTIFUME® Line Burner Designation
Example: 12" x 12" bk inlet section CF 5 – BX – D – 24
Mixing Plate Material4 = #310 stainless steel5 = Hastelloy-X
Section Code6 = 6" straight section12 = 12" straight sectionT = 12" x 6" tee sectionX = 12" x 12" cross section12B = 12" back inlet straight sectionBX = 12" x 12" back inlet cross sectionBH = 36" back inlet “H” section
CF = COMBUSTIFUME® BurnerIP-CF = INCINO-PAK® Burner
Body MaterialD = ductile iron bodyB = aluminum bronze body
The designationof each
COMBUSTIFUME®
Burner sectionidentifies specificsabout that section.
Section Description
[1] These drill patterns available for special applications such aslow Btu/fuels and partial premixing system
Number of (#30) drilled holes per lineal foot24 = 24 holes (0.3113 in2/ft) discharge area48 = 48 holes (0.6226 in2/ft) discharge area [1]96 = 96 holes (1.2451 in2/ft) discharge area [1]120 = 120 holes (1.5564 in2/ft) discharge area [1]
deeftelnirofsnoitatimilyticapacgnirifsagwaRsnoitces
EMUFITSUBMOC ® renruBmumixaM
telnireprh/utBeziSepiPtelnI)TPN(
noitceSrenruB
"2
tesegnalftelnidnE 000,005,3
)B21(thgiarts"21000,000,7
KAP-ONICNI ® )B63&B21(
"3
)HB(telnikcab"63 000,003,8
)B21(thgiarts"21000,000,01
)BX(ssorc"21x"21"4 000,000,21
COMBUSTIFUME® Line Burners Page 5711
9/03
Performance Selection DataINCINO-PAK® Burner Inlet Feed Sections
INCINO-PAK® Burner sections are specialconfigurations of 12" or 36" back inlet feed sections.They provide “outside-the-duct” access to the raw gaspilot, ignitor, and flame safeguard components,eliminating lateral duct wall connections.
INCINO-PAK® Burner sections are designed tofeed COMBUSTIFUME® Burner elements in end-firedincinerators or preheaters with cylindrical combustionchambers, or when burner is fired at an elbow in theductwork.
INCINO-PAK® Burner sections can be used alone(with appropriate end plates and accessories added),or as an inlet feed section in a largerCOMBUSTIFUME® Line Burner assembly.
All INCINO-PAK® Burner sections contain a 2"(NPT) gas inlet connection which may be used tofeed up to a maximum capacity of 7,000,000 Btu/hr.
Heat release and gas pressure requirementsmatch those of the other COMBUSTIFUME® sections.The raw gas pilot capacity is 25,000 Btu/hr.
WARNING: Pilot gas should be interruptedonce main flame is established. UV sight tubemust be sealed against any scanner cooling airused.
36" back inlet “H” INCINO-PAK® Burner section shown with (4)COMBUSTIFUME® Burner end plates; includes spark ignitor, pilotgas adjustable orifice cock, raw gas pilot, and arranged formounting of customer’s UV scanner
Three manifold lengths are offered in both the 12Band 36B back inlet INCINO-PAK® Burner sections:Series 600 = 600 millimeter (23.8") lengthSeries 800 = 800 millimeter (31.5") lengthSeries 1100 = 1100 millimeter (43.3") length
This “manifold length” reflects the distancebetween the outside duct mounting wall and thecenterline of the COMBUSTIFUME® Burner casting.See catalog page 5712 for specific dimensions.
Each INCINO-PAK® Burner section includes aspark electrode, adjustable pilot gas orifice, bodygasket, and provision for your UV scanner.
Typical block & bleed piping layout for raw gas INCINO-PAK®
Burner system as frequently required by insurance authoritiesTypical installation
in cylindrical incinerator
Maxon assumes no responsibility for the use or misuse of the pipinglayout shown. Specific piping and wiring diagrams should always besubmitted to the approproate agencies for approval on each application.
Page 5712 COMBUSTIFUME® Line Burners
Dimensions (in inches)
INCINO-PAK® Burner Back Inlet Sections
36" back inlet “H” section
12" back inlet “12B” section
Pipe threads on this page conform toNPT (ANSI Standard B2.1)
seireS A B L X
006 18.32 52.73 56.13 5.1
008 5.13 52.54 43.93 57.1
0011 13.34 52.65 51.15 1
COMBUSTIFUME® Line Burners Page 5713
9/03
Envelope Dimensions (in inches)
Modular Burner Sections
12" x 6" teesection
12" x 12" crosssection
12" straightsection
6" straightsection
Typical End Views
Tee andCross Sections
StraightSections
Page 5714 COMBUSTIFUME® Line Burners
Envelope Dimensions (in inches)
Modular Inlet Feed Burner Sections
36" back inlet section12" back inlet section12" x 12"
back inlet cross
NOTE: 12B, 36B and XB back inlet sections must be orderedwith one of the back inlet flange sets shown below.
Back Inlet Flanges
Flange Sets for 12" & 36"Back Inlet Sections
2"LFB
3"LFB
Flange Sets for 12" x 12"Back Inlet Cross Sections
3" 4"
Inlet flanges bolt directly toburner casting and accepteither standard NPT orstandard ISO threaded pipingof indicated size.
NOTE: Refer to page 5710for specific inlet feed capacitylimitations.
)ezis(A B
2 88.0
3 52.1
)ezis(A
3
4
COMBUSTIFUME® Line Burners Page 5715
9/03
Envelope Dimensions (in inches)
End Closures and End Inlet Flange Sets
All open ends of a burner assembly must be closed off with one of these end closures,or with a pilot end plate or pilot assembly as shown below and on page 5716.
Alternateflame rodposition
Inlet pilot set
UV scanner can bemounted through straight-in flame rod location. 1"tap is bushed to 1/4" forflame rod.
Flame rods ( if used) must beordered separately with all pilot end plate sets.
Plain end plate set
Plain end plate closureincludes 1/8" NPT testconnection
Pilot end plate set
UV scanner can bemounted through straight-in flame rod location. 1"tap is bushed to 1/4" forflame rod.
NOTE: See catalog page5710 for specific inlet
feed capacity limitations.
Page 5716 COMBUSTIFUME® Line Burners
Envelope Dimensions (in inches)
Pilot Assemblies
Built-in pilot arrangementsDirect mounted version includes 14mm spark
ignitor. Order electrode separately for externallymounted version. Order flame rod (if used) sepa-rately.
NOTE: Built-in pilot assemblies must mount onlywhere COMBUSTIFUME® Burner sections provide forthe segmented gas chamber within the burner bodycasting. See sketches below relative to possiblelocations for built-in pilot assemblies.
Optional external mounting assembliesshown on page 5718
Built-in pilot detail
All 6" straight sections,whether gray iron, ductileiron, or aluminum bronze,can accept built-in pilots onone end.
Aluminum bronze 12" x6" tee section can acceptbuilt-in pilot only on rightend of straight 12" side(when viewed from backside of the assembly).
Ductile iron 12" x 6" teesections can have built-inpilot assembly mounted onany end.NOTE: Gray iron teesections do not acceptbuilt-in pilot assemblies.
COMBUSTIFUME® Line Burners Page 5717
9/03
Envelope Dimensions (in inches)
Pilot Assemblies
AIRFLO-PAK pilot arrangementsDirect mounted version includes 14mm spark
ignitor. Order electrode separately for externallymounted version. Order flame rod (if used) and pilotmixer separately.
Optional air/gas pilot mixersfor all COMBUSTIFUME® Burner AIRFLO-PAK pilotassemblies
Pressure type with adjustable orifice
Atmospheric type with fixed orifice
External Mounting Plate Assemblies
Positioning mounting plate in relation toAIRFLO® Burner pilot location
External mounting plate details – A plate isincluded with all assemblies shown on page 5718
Mounting Plate with two(2) feed-through insulatorsfor internal mounting ofspark ignitor and flamerod. Same size externalmounting plate used in allassemblies shown onpage 5718.
External mountingplate dimensions
Through-wallopening required
Page 5718 COMBUSTIFUME® Line Burners
Dimensions (in inches)
External Mounting Plate Assemblies
As used with built-inpilot assemblies
As used with AIRFLO-PAKpilot assembliesDescription
Description
External mounting plateassembly for externalspark electrode &external UV scanner
NOTE: Order optionalspark electrode sub-assembly separately
External mounting plateassembly for external UVscanner & internal sparkignitor
External mounting plateassembly for internalspark ignitor & internalflame rod
Optional external(shrouded) sparkelectrode for above
External electrode 12" 18" 24" 36"Dimension “A” 12 18 24 34.437Dimension “B” 13.781 19.781 25.781 36.170
COMBUSTIFUME® Line Burners Page 5719
2/13
Accessory Dimensions (in inches)
Profile Plate BracketProvides support for profile
within closed burner loop. Onsome applications, it may benecessary to restrict air flowbetween adjacent burnerrows to achieve designoperating velocities. This isdone by installing customer-fabricated profile plateson profile mounting bracket(s). See sketch 1 belowfor use on square openings (formed by adjacentcross-sections of burner). Sketch 2 applies torectangular opening.
Universal support bracketNormally used in pairs as shown below. Mount to
burner assembly at any joint between sections.Two versions available: zinc plated carbon steel for
maximum inlet temperature up to 750°F (399°C) or#304SS for maximum inlet temperature up to 1600°F(871°C).
Division plateProvides isolation of burnerfeed(s) where desirable.
1
2
14mmSpark Ignitor
SparkElectrode
Flame rod identificationFor those COMBUSTIFUME® Burners using flame
rods, most applications are covered by one of twosizes (specific number depends on nominal length “N”of rod extension). These may need cut to dimension“L” specified in tables on page 9908A before use inyour particular application.
N
7-1/2"
24"
Optional electrode coverProtects porcelain insulator andelectrical connection from dirtand moisture. May be used forambient temperatures up to450°F (232°C).
Page 5720 COMBUSTIFUME® Line Burners
Component IdentificationINCINO-PAK® Burner Back Inlet Feed Section
Nameplate located onINCINO-PAK® Burner gas inlet body
Nameplate located onCOMBUSTIFUME® Burner body
A
BC
D
A
B
COMBUSTIFUME® Line Burners Page 5721
9/03
Component IdentificationCOMBUSTIFUME® Line Burners
ItemNumber
1 Burner body2 Back up bar (straight)3 Gasket, body (straight)4 Back up bar (inside)5 Gasket, inside6 Back up bar (outside)7 Burner body gasket (between joints)8 Support bracket gasket 18 GA9 6" mixing plate10 Corner mixing plate
12 M10 - 1.5 x 45 hex head cap screw13 M10 - 1.5 finished hex nut14 #10 -24 FLEX-LOK hex nut15 #10 -24 x 1/2" indented hex head machine screw16 #10 -24 x 2-1/4" indented hex head machine screw17 Washer18 #10 -24 x 3/8" indented hex head machine screw
19 M10 - 1.5 hex nut finished20 M10 - 1.5 x 35 hex head cap screw21 1/4" -20 x 3/4" hex head cap screw
Part DescriptionTo order replacement parts:1. Identify specific COMBUSTIFUME®
series/type from burner assemblyinformation plate pictured on page 5720.
2. Provide sketch of burner arrangement,as viewed from back (or casting side) ofassembly. For example:
3. Specify quantity of each replacementitem required from table at right.
Page 5722 COMBUSTIFUME® Line Burners
Notes