an investigation of the contamination related to the south hill tce spill a class project for: bee...

Post on 13-Jan-2016

221 Views

Category:

Documents

2 Downloads

Preview:

Click to see full reader

TRANSCRIPT

An Investigation of the Contamination Related to the

South Hill TCE Spill

A class project for:

BEE 672 / EAS 471

Professors:Dr. Larry Cathles- Earth and

Atmospheric Science

Dr. Tammo Steenhuis- Biological and Environmental Engineering

Site HistoryA quick look back at South Hill…

Ken Deschere

A BIG part of our Hill …

TCE used for degreasing

• Radian Consultants, July 1987:

For more history and references:

TCE Toxicological Profile

Jennifer Smith

TCE Background

• Legal – typewriter correction fluids,

paint removers/strippers, adhesives, rug cleaning fluids, solvent

– 1977 FDA ban on use as anesthetic, wound disinfectant, pet food additive

• Ubiquitous in the Environment– 9-34% drinking water has TCE

• Low bioconcentration/biomagnification

Cl Cl

Cl

CC

H

Exposure

• Background levels – 30 mill pounds emitted to atmosphere in US– Urban air 1983: 0.04-0.72, 0.39, 0.21-0.59 ppb

• Exposure Routes– Inhalation: 50% exhaled out

• Other exposures– milk, cheese and butter (0.3-10 ppb); oils and fats

(0-19 ppb); canned fruit drinks, ale, instant coffee, tea, and wine (0.02-60 ppb); fruits and vegetables (0-5 ppb); and bread (7 ppb)

– Breast milk

Toxicity

• Well studied at higher concentrations• Central nervous system damage

– dizziness (100 ppm), headache (27 ppm), nausea (81 ppm), and confusion

– eye and respiratory irritation– damage to kidneys and liver

• Cancer: liver, kidney, cervical – NOEL 20 ppm

Toxicity

• Drinking water– 5-600 ppb caused increased arthritis, seizure or

convulsions, mood disorders; decreased blink reflex, eye closure, choice reaction time, and intelligence test scores

– 270 ppb caused increased respiratory infections in children

• Co-contaminants (PERC and MC)• Sensitive populations: smoke/drink, children,

elderly, breastfed babies

Geology

Rachel Shannon

South Hill Site South Hill Site Description Description

Photo by Regina Deschere

Photo by Regina Deschere

Joints

Diagram built from information in ESC report received at Thompkins County Library on March 18, 2005

Photo by Regina Deschere

South Hill Geology:

layeredand

fracturedsiltstone

Basic Hydrology

Adrian Harpold

Hydrologic Processes on a Hillslope

Water Transport: Seeps and Springs

Seeps occur when an impermeable layer in the soil blocks recharge and causes formation of a perched water table; the water can flow sideways out of the soil.Springs occur when the water table is higher than the ground surface.

Hydrology of South Hill

• Groundwater moves to the Northwest in most locations.

• There is a steep gradient in the groundwater table.

• Human induced changes can have a dramatic impact on hydrology:– Pipes– Excavation and fill material– Asphalt and impervious surfaces

Hydrology at South Hill

Clear connectivity between soil and bedrock.

Water in the bedrock moves through fractures.

Shallow soils can lead to saturation and seeps.

Vertical movement of groundwater dominates lateral movement.

TCE Properties and Forms

M. Ekrem Cakmak

Properties of TCE and Related Properties of TCE and Related Transport ProcessesTransport Processes

•Denser than water (1.46 kg/L > 1.00 kg/L), pools in the subsurface.

•Not easily dissolved and removed by water.

•Not easily degraded by microorganisms.

•Prefers to be in vapor phase.

Russel et al., 1992, EPA.

Forms of TCEForms of TCE

From: www.dnapl.group.shef.ac.uk

1. (D)ense (N)on (A)queous (P)hase (L)iquid• moves freely from groundwater movement and forms pools.

3. Vapor (highly volatile) (2985 mg/L in air @ 20 °C)• Thought to be responsible for intrusion

2. Dissolved in ground water (max. 1000 mg/L in water)• Solubility of salt in water (360,000 mg/L)

Transport Mechanisms

Adrian Harpold

Transport Mechanisms

• Several different transport pathways are possible.

• Distinguishing between different transport pathways is difficult.

• Identification of transport pathways is critical for determining optimum remediation strategies.

Deep Invasion of TCE is likely

• Fire reservoir was built into bedrock

• DNAPL sink• Low retardation of

TCE• Fractured nature of

bedrock at South Hill

Reservoir

‘Back-flow’ from Bedrock Fractures Prolongs Contamination

Can cause long-term persistence of TCE after ‘free’ TCE has been transported through the system.

Very difficult to remediate.

Diffusion of TCE Vapor

Diffusion: movement caused by the random (Brownian) motion of molecules. Rates of diffusion depends on material (TCE) and medium (water or air).

• Continuous Process• Factor effecting diffusion:

– Height of water table– Concentration of TCE

vapor– Temperature

Groundwater encounters soil contamination and adds to advective transport

Capillarity hold some groundwater with VOCs above the water table which

increases diffusion

Contaminated water reaching the surface

Very little contaminated water can cause air problems.

Only a problem when groundwater is high (most probable in the Spring or after long rainstorms).

Degradation of TCE

• Controlled by– Oxygen– Carbon– Temperature

• Many by-products• Difficult to deduce

degradation at South Hill site

Vapor Intrusion

‘Stack-Effect’

Vapor intrusion is the ‘catch-all’ term for the movement of TCE vapor from the subsurface to the surface.

Vapor flow along a preferential pathway

Vapor Intrusion

Groundwater flow direction (not necessarily related to perched aquifer flow direction

diffusion of vapors off gassing

from perched aquifer

Because TCE is heavier than air it can move under its own weight. Steep water table and bedrock gradients make this possible at South Hill.

Hypothesized Transport Scenario

• Confirmed Source: Fire Reservoir• Short-term transport: large fractures in the

bedrock, flushing TCE down steep gradients to the bottom of the hill.

• Long-term transport: deep bedrock, back diffusion, and deep pools.

• Vapor transport: diffusion is dominant in soil, other vapor intrusion pathways may exist

• Factor effecting this scenario: degradation and amount and other sources of TCE

Spring Water and Basement Air Sampling

Veronica Morales

• There are several different transport mechanisms that in combination determine the fate of DNAPL intrusion into South Hill residences.

• Tests conducted would confirm two suspected pathways, determine their dominance and identify the factors that affect TCE behavior.

Purpose of Sampling Team

• Formulate a simple and inexpensive method to test some of these pathways and influential environmental factors.

• Collect and analyze an extensive series of data from water and air samples.

Spring water sampling

• The identification of dissolved TCE or its degradation products in spring water could provide evidence of possible DNAPL sources upstream of the spring.

• TCE dissolved in spring water may be indicative of contaminated water and/or vapor intrusion into nearby homes.

Identified Springs and Seeps

• Non detectable concentrations of VOCs in spring water tests in past could be attributed to: – Absence of VOCs in ground water path

– Volatization of VOCs as water emerges from springs

– Sample collection

Given that subsurface conditions are constantly changing, we would like to continue monitoring this potential pathway.

Basement air sampling

• If possible, determine optimum sampling conditions for indoor air sampling.

• Confirm that the few samples collected are justifiable averages of the indoor conditions.

Collected data should initially be analyzed for the following parameters:

– Spatial analysis• From house to house

– Ground water trends• increasing/decreasing water levels• temperature changes

–Temporal variations• daily, weekly and seasonal

General Sampling Methods

Passive diffusion onto sorbent

Active sampling with sorbent

Conclusions If the sampling strategy proves effective:

• Analysis could increase the comfort level of residents.

• Strategy could be employed to screen a broader affected area more quickly and more cost effectively.

• With additional investment on equipment, it may be feasible for Cornell students to perform these simple analysis cheaply.

Suggestions

Economic Impact

Ian Toevs

Economic Impacts of the South Hill TCE Contamination

• Property value

• Cost of mitigation system operation

• Evaluation of two mitigation strategies

• Emerging negative impacts– Houses are on the market longer– Receive fewer bids- less interest

Property Value

Selling price over assessed value:

2003-2005 2004-2005

South Hill 38.9% 19.6%

Study area - 26%

Ithaca 30.3% 6.3%

Operation Cost of Mitigation System

• Suction fans require energy– Annual cost ranges from

<$20 to >$260– Some systems will require

more than one fan

• Maintenance– Emerson has agreed to

install and maintain

From http://www.infiltec.com/inf-fanr.htm

Model Watts kW-hr/yrannual cost

($0.12/kW-hr)RP140 14-20 148.92 $17.87XP101 40-49 389.82 $46.78XP151 45-60 459.9 $55.19XP201 45-65 481.8 $57.82RP145 37-71 473.04 $56.76XR261 65-105 744.6 $89.35RP265 86-140 989.88 $118.79GP201 40-60 438 $52.56GP301 55-90 635.1 $76.21GP401 60-120 788.4 $94.61GP501 60-140 876 $105.12GP500 70-130 876 $105.12FR225E 112-153 1160.7 $139.28FR250E 133-245 1655.64 $198.68

HS2000 150-270 1839.6 $220.75HS3000 105-195 1314 $157.68HS5000 180-320 2190 $262.80

RADON FAN POWER REQUIRMENTS

VERY HIGH SUCTION RADON FANS

Mitigation vs. Sampling Costs

• Mitigation– Average cost $2500 / house– Follow-up sample(s)

• Sampling– Approx. $800 / sample X 3 at each house = $2400 /

house– Most houses have been tested 2- and some even 3-

times

• Other important factors– Time- unnecessary additional exposure– The benefit of a happy and healthy community

Questions?

top related