The PNA Bollard Base Helps You:n Collectyourretainagen Reduceyourcallbacksn Simplifyinstallationandreducelaborcostsn Reducemaintenancecostsn Installbollardstoexactingtolerancesn Delivercost-effectiveconcreteflatwork

Efficient ConstructabilityEliminatetheneedforcoredrillingnowandinthefuturebyplacingthePNAbollardbaseonthesubgradebeforeconcreteplacement.Itisinevitablethataforktruckwillhitabollard.WiththePNAbollardbasethebollardorweldwillfail,andtheconcreteslabwillstayintact.Whenyouremovethedamagedbollard,theexposedsteelisreadytogrindandinstallanewbollard.ThePNAbollardbasecanbeplacedinaconcreteslabforfutureusewithoutcompromisingtheslabintegrity.Thebasewilltakerepetitiveloadingfromforktrucktrafficwithoutriskofdamage.

BollArd BAsESimple and flexible bollard inStallation

Product Materials and Processes:n Bollardbasesaremanufacturedfromsteelcertifiedto

meetASTMA36toensurereliablequalityandperformancen Platesaresawnorplasmacutfull-depthanddeburredper

industryguidelinestoensureplateedgesaresmoothsotheywillnotinducerestraint

n Extracted,harvestedorrecovered,aswellasmanufactured,intheUSAfromrecycledsteelandeligibleforLEED®credits

Bollard size:size of top steel platen 17-3/4"round(451mm)n 16"square(406mm)n 24"square(610mm)

Headed anchor length (determined by slab depth)n2inch(51mm)n3inch(76mm)n4inch(102mm)

Performance-Based Engineering:n Engineerthepointoffailure,bollard,weldorconcrete,

throughthespecificationofthetypeandsizeoftheweld;convertthedynamicload-on-impacttoastaticloadatthepointofimpactasdeterminedbytheforktruckdesign

n Deliversflexibilityoffacilitylayout–embedinslabforusenoworinthefuture

n Reducestheriskofconcretefailure

Youcaneasilyandreliablyinstallabollardwhileproducingahigh-quality,finishedappearancewiththePNAbollardbase.Indemandingwarehouse,retailandindustrialenvironmentsbollardsareinstalledforareason–toprotectkeyelementsofthebuildingfromdamage.Historicalmethodsofinstallingabollardtransferthedamage-on-impactfromthewalltotheconcreteflatwork,whichiscostlytoreliablyrepair.PNA’sbollardbasesimplifiesbollardinstallationandreplacementwhileensuringminimaldamagetotheconcreteflatwork.

PNA bollard base on level subgrade

Easy-to-finish to edge of plate

Pr

AC

TiC

Al iN

No

vA

Tio

N. P

ro

vE

N P

Er

for

MA

NC

E.™

w w w . p n a - i n c . c o m • p h o n e : 8 0 0 . 5 4 2 . 0 2 1 4 C o N C r E T E s l A B s - o N - g r o u N d

©2010.PNAConstructionTechnologies,Inc.Allrightsreserved.01/10.ProductsareregisteredtrademarksofPNAConstructionTechnologies,Inc.andmaybecoveredbyoneormoreU.S.,internationalorpendingpatents.Visitwww.pna-inc.comforthelistoftrademarksandpatents.

top related