FLEXIBLE AC CURRENT PROBE
FlexProbe®
24-3001 24-3002
E N G L I S H User Manual
®INS TRUMEN TS
CAT III1000V
300A
3000A
OFF
ONOL
FlexProbe ®
24-3002
Statement of Compliance
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments certifies that this instrument has been calibrated using standards and instruments traceable to international standards.
We guarantee that at the time of shipping your instrument has met its published specifications.
An NIST traceable certificate may be requested at the time of purchase, or obtained by returning the instrument to our repair and calibration facility, for a nominal charge.
The recommended calibration interval for this instrument is 12 months and begins on the date of receipt by the customer. For recalibration, please use our calibration services. Refer to our repair and calibration section at www.aemc.com.
Serial #: ________________________________
Catalog #: 2120.81 / 2120.82
Model #: 24-3001 / 24-3002
Please fill in the appropriate date as indicated:
Date Received: _________________________________
Date Calibration Due: _______________________
Chauvin Arnoux®, Inc.d.b.a AEMC® Instrumentswww.aemc.com
Table of Contents
1. INTRODUCTION ............................................................................... 21.1 International Electrical Symbols ................................................21.2 DefinitionofMeasurementCategories .....................................31.3 ReceivingYourShipment ..........................................................31.4 OrderingInformation .................................................................3
1.4.1 AccessoriesandReplacementParts ............................3
. PRODUCT FEATURES ...................................................................... 42.1 Description ................................................................................42.2 GeneralFeatures ......................................................................52.3 FlexProbe®24-3001Features ..................................................62.4 FlexProbe®24-3002Features ..................................................7
3. SPECIFICATIONS............................................................................. 83.1 ElectricalSpecifications ............................................................83.2 EnvironmentalSpecifications ....................................................93.3 MechanicalSpecifications ........................................................93.4 SafetySpecifications ..............................................................10
4. OPERATION .................................................................................. 114.1 MakingMeasurementswiththeFlexProbe® ...........................114.2 TipsforMakingPreciseMeasurements..................................12
5. MAINTENANCE ............................................................................. 14Warning ...........................................................................................145.1 ChangingtheBattery ..............................................................145.2 Cleaning ..................................................................................14
RepairandCalibration ...........................................................................15TechnicalandSalesAssistance ............................................................15Limited Warranty ...................................................................................16WarrantyRepairs ...................................................................................16
2 FlexProbe® - Flexible AC Current Probe
CHAPTER 1
INTRODUCTION
WARNING • Read the instruction manual completely and follow all the safety
informationbeforeattemptingtouseorservicethisinstrument.• Wearprotectiveclothingandglovesasrequired.• Use caution on any circuit: potentially high voltages and currents
maybepresentandmayposeashockhazard.• Read the safety specifications section prior to using the current
probe.Neverexceedthemaximumvoltageratingsgiven.• Safetyistheresponsibilityoftheoperator.TheFlexProbe®mustbe
used only by qualified personnel using applicable safety precau-tions.
• ALWAYS de-energize the circuit before wrapping the FlexProbe® aroundbareconductors,busbars,ornearliveparts.Donotwraponliveconductors.
• ALWAYSconnecttheelectronicmoduletothedisplaydevicebeforewrappingtheFlexProbe®aroundthesamplebeingtested.
• ALWAYSinspectthemodule,sensor,sensorcable,andoutputtermi-nalspriortouse.Replaceanydefectivepartsimmediately.Useonlyfactoryparts.
• NEVER use the FlexProbe® on electrical conductors rated above1000V Cat. III and 600V Cat. IV.
1.1 International Electrical SymbolsThis symbol signifies that the instrument is protected by double or reinforced insulation.This symbol on the instrument indicates a WARNING and that the operator must refer to the user manual for instructions before operating the instrument. In this manual, the symbol preceding instructions indicates that if the instructions are not followed, bodily injury, installation/sample and product damage may result.Risk of electric shock. The voltage at the parts marked with this symbol may be dangerous.This symbol refers to a type B current sensor. Do not apply around or remove from HAZARDOUS LIVE conductors without additional protective means (de-energizing the circuit or wearing protective clothing suitable for high voltage work).
In conformity with WEEE 2002/96/EC
FlexProbe® - Flexible AC Current Probe 3
1.2 Definition of Measurement CategoriesCat. I: Formeasurementsoncircuitsnotdirectlyconnected to theAC
supplywall outlet such as protected secondaries, signal level,andlimitedenergycircuits.
Cat. II: Formeasurements performed on circuits directly connected totheelectricaldistributionsystem.Examplesaremeasurementsonhouseholdappliancesorportabletools.
Cat. III: For measurements performed in the building installation atthe distribution level such as on hardwired equipment in fixedinstallationandcircuitbreakers.
Cat. IV: For measurements performed at the primary electrical supply(<1000V) such as on primary overcurrent protection devices,ripplecontrolunits,ormeters.
1.3 Receiving Your ShipmentUponreceivingyourshipment,makesure that thecontentsareconsis-tentwith thepacking list.Notifyyourdistributorofanymissing items. Iftheequipmentappearstobedamaged,fileaclaimimmediatelywiththecarrierandnotifyyourdistributoratonce,givingadetaileddescriptionofanydamage.Savethedamagedpackingcontainertosubstantiateyourclaim.
1.4 Ordering InformationFlexProbe® 24-3001 (300/3000AAC,24",10mV/A/1mV/A,withlead) ....Cat. #2120.81
FlexProbe® 24-3002 (300/3000AAC,24",10mV/A/1mV/A) ................Cat. #2120.82Both models include a flexible probe with electronic module, 9V battery, user manual and a product warranty and registration card.
1.4.1 Accessories and Replacement PartsBanana(Female)/BNC(Male)Adapter............................. Cat. # 2118.46ForconnectionofFlexProbe®toBNCterminalsonscopesandotherdis-playinginstruments.
Order Accessories and Replacement Parts Directly OnlineCheck our Storefront at www.aemc.com/store for availability
4 FlexProbe® - Flexible AC Current Probe
CHAPTER 2
PRODUCT FEATURES
2.1 DescriptionTheFlexProbe®isaflexibleACcurrenttransformercomposedofaflexiblesensorandanelectronicmodule.Theflexiblesensorpermitsmeasure-mentsonconductorswherestandardclamp-onprobescouldnotbeused.Inparticular, it canbe installed in tight spaces,aroundbreakerpanels,aroundcablebundles,aroundwideor largebusbars,orevenwrappedaroundirregularshapes.
TheShapeMemory featureenables theuser to “pre-shape” thesensorbeforeinsertingitbetweenoraroundconductors.Thisfeaturefacilitatesclosing,enhancesusersafety,andalleviatesthedroopingeffecttypicallyassociatedwithflexiblesensors.
TheFlexProbe®islightweight.Itdoesnotusemagneticcoreslikestandardtransformers.Thetransformationprincipleisbasedonanaircore.Itpres-entsvirtuallynoloadtothesystemundertest,hasalowphaseshiftandexcellentfrequencyresponse,andcannotbedamagedbyoverloads.
Thesensorassemblyiswaterproofandinsulatedfor1000VCat.III;600VCat.IV.TheFlexProbe®meetsEN61010,isCEmarked,andisdesignedwithmaterialsandcomponentstomeetUL3111,andinternationalagencyapprovals.
TheFlexProbe® hasamVoutput proportional to the currentmeasuredfordirectreadingsonDMMs,dataloggers,oscilloscopes,andpowerorharmonicmeters.TRMSmeasurementsaretakenwhenconnectedtoaTRMSmeter.TheFlexProbe® isinsensitivetoDCcurrentsandonlytheACcomponentofthemeasuredsignalismeasured.
Thelengthof theflexiblesensorcanbeselected in lengthsof24",36",and48"inlength.Consultthefactoryforcustomlengths,rangesand/orfeatures.
FlexProbe® - Flexible AC Current Probe 5
2.2 General Features• Modelstomeasurefrom0.5to30000Arms
• Accuracy1%ofReading
• TRMSmeasurementswhenconnectedtoaTRMSinstrument
• Nocoresaturationordamageifoverloaded
• OverrangeLEDformeasurementcircuitry
• EN61010;1000VCat.III;600VCat.IV
• Waterproofsensor
• 9Vbatteryfortypical150hourcontinuousoperations
• ShapeMemory™forcustompre-shapingofsensorbeforeuse (nodrooping)
• Highfrequencyresponse
• Lowphaseshiftforpowermeasurements
• InsensitivetoDC,measuresonlyACcomponentonDC+ACsig-nals
• Excellent linearity
• Lightweight
6 FlexProbe® - Flexible AC Current Probe
2.3 FlexProbe® 24-3001 Features
®
INS TRUMEN TS
CAT III1000V
300A
3000A
OFF
ONOL
FlexProbe ®
24-3002
1
2
3
6
4
5
8
7
1. Flexiblesensor(Ø0.5",12.5mm)
2. Rangeselectionswitch
3. PowerONindicator(GreenLED)
4. Overload indicator (Red LED)
5. Electronicmodule
6. Doubleinsulated14"(36cm)leadwithsafetybananaplugs
7. FlexProbe®connector/latch
8. Sensor lead
FlexProbe® - Flexible AC Current Probe 7
2.4 FlexProbe® 24-3002 Features
®
INS TRUMEN TS
CAT III1000V
300A
3000A
OFF
ONOL
FlexProbe ®
24-3002
1
2
3
4
5
6
7
9
8
1. Flexiblesensor(Ø0.5",12.5mm)
2. Rangeselectionswitch
3. PowerONindicator(GreenLED)
4. Common:Blackbananajack(-)
5. Positive:Redbananajack(+)
6. Overload indicator (Red LED)
7. Electronicmodule
8. FlexProbe®connector/latch
9. Sensor lead
8 FlexProbe® - Flexible AC Current Probe
CHAPTER 3
SPECIFICATIONS
Reference Conditions: 41°F ± 5°F (23°C ± 3°C), 20 to 70% RH, 50Hz, 1 minute warm-up, battery at 9V ± 0.1V, external magnetic field < 40A/m, no DC component, no external current carrying conduc-tor, 10MΩ load, conductor center.
3.1 ElectricalCurrent Range: 300/3000AAC
Output Signal:mVoutput(4000mVpeakmax)
Three position slide switch: 10mV/A 5A to 300Arms 1mV/A 50A to 3000Arms ON/OFF
AC Current Accuracy (after calibration and for one year):1%ofReading±500mA
Crest Factor: 4.5
Phase Shift:<0.7°at50or60Hz
Frequency Range:40to5kHz
Residual Noise When I Measured = 0: 200mArms
Working Voltage: 1000Vrms max (Cat. III)
Common Mode Voltage: 600Vrms max
Influence of Frequency: Add1%tothereferenceaccuracybetween40and2000Hz,andupto5%at5kHz
Influence of Adjacent Conductor: <2%
Influence of Conductor Position in Jaw: <4%
Power Source:9Valkaline(NEDA1604A,IEC6LR61)
Battery Life: 150hourstypical(continuoususe) 300hourswithLithiumbattery
FlexProbe® - Flexible AC Current Probe 9
Low Battery:GreenLEDOffwhen≥7V
Overload Indication: RedLEDindicatesinputgreaterthanselectedrange
3.2 EnvironmentalOperating Temperature Range: 14°to131°F(-10°to+55°C)
Storage Temperature Range: -40°to158°F(40°to+70°C)
Influence of Temperature:Sensor:-14°to212°F(-10°to100°C);<0.5%per10°CModule:-14°to131°F(-10°to55°C);<0.5%per10°C
Operating Relative Humidity:50°to86°F(10°to30°C);85±5%RH(withoutcondensation)104°to122°F(40°to50°C);45±5%RH(withoutcondensation)
Altitude: Operating:0to2000m Non-operating:0to12000m
3.3 Mechanical SpecificationsDimensions (Sensor): 24"±1"(610x25mm)
Color (Sensor): Redwithblackconnector
Dimensions (Electronic Module):4.9x2.5x1.1"(124x64x28mm)
Color (Electronic Module): Darkgray
Weight: 1.1lb(0.5kg)
Output:
Model 24-3001:Doubleinsulated14"(36cm)leadwithsafetybananaplugs
Model 24-3002:4mmsafetybananajacks(redandblack)
Maximum Cable Diameter: 7.6"(193mm)
Cable Length from Sensor to Module:6.5ft(2m)
Drop Test:1.0mon38mmofOakonconcrete.TestaccordingtoEN61010.
10 FlexProbe® - Flexible AC Current Probe
Case Protection: Sensor:IP65 ElectronicModule:IP40
Vibration: Test Per IEC 68-2-6
Frequency Range:10to55Hz
Amplitude: 0.15mm
Mechanical Shock: 100G,TestPerIEC68-2-32
Material: Module:UL94V2 CableAssembly:UL94V0
3.4 Safety SpecificationsElectrical SafetyDoubleinsulationorreinforcedinsulationbetweentheprimaryorthesec-ondaryandtheoutercaseofthehandleperEN61010.
EN61010,1000VCat.III,600VCat.IV
PollutionDegree:2
Electromagnetic Compatibility:
EN 50081-1 Class BEN50082-2 ElectrostaticdischargeIEC1000-4-2 Radiated Field IEC 1000-4-3 Fast transients IEC 1000-4-4MagneticFieldat50/60HzIEC1000-4-8
*Specifications are subject to change at any time without notice
FlexProbe® - Flexible AC Current Probe 11
CHAPTER 4
OPERATION
Pleasemakesure thatyouhavealready readand fullyunderstand theWARNINGsectiononpage2.
4.1 Making Measurements with the FlexProbe®
1. ConnecttheelectronicmoduletotheACVoltrangeofyourDMMormeasuringinstrument.
2. Select the appropriate module output voltage range. If the currentmagnitudeisunknown,selectthe3000Arange.
3. Wraptheflexiblecorearoundtheconductortobetested.Selectthe300Arange toobtain thebest resolution, if the reading is less than300mV.
Do not exceed specified current range for the output. Do not use on selected range if Overload LED goes on.
4. Example:
a. ReadtheDMMdisplayedvalue:2.59V
b. DeterminetherangeandoutputusedontheFlexProbe:0.01V/Aforthe300Arange;.001V/Aforthe3000Arange
c. Dividethereadingbytheoutputtodeterminetheactualcurrentvalue:2.59÷0.01=259Aor2.59÷0.001=2590A
Forbestaccuracy,carefullycentertheconductorinsidetheflexiblecore,andavoidifpossible,theproximityofotherconductorswhichmaycreatenoiseandinterference(particularlynearthelatch).
TrueRMSmeasurementsareobtainedwhentheFlexProbe® is connected toaTrueRMSmeter.NotethattheDCcomponentisnotmeasured.
12 FlexProbe® - Flexible AC Current Probe
4.2 Tips for Making Precise Measurements
• When using the FlexProbe® with a meter, it isimportant to select the range that provides thebest resolution. Failure to do this may result inmeasurementerrors.
• For best results, select the highest FlexProbe® output signal possible and the most sensitivemeterrangeforthisoutput.
• MakesuretheDMMormeasuringinstrumentcanaccurately measure mVAC. Certain inexpensiveDMM have poor resolution and accuracy whenmeasuringlowmVAC.
• Forbestaccuracy,centertheFlexProbe®aroundtheconductortobemeasured.
• Toincreasethesensitivityormeasureonlowcur-rents, the FlexProbe® may be wrapped severaltimesaroundtheconductor.Remembertodivideyourreadingbythenumberofturnsfortheactualmeasurement(SeeFigure1).
• TheoverallmeasurementaccuracyisthesumoftheFlexProbe® accuracyandthedisplayinginstru-mentaccuracy.
• TheFlexProbe®maybedoubledaroundthecon-ductortobemeasuredtodoubletheoutput.(SeeFigures1and2toshowthedifferentvaluesonaDMMwhilemeasuring250AAC.)
FlexProbe® - Flexible AC Current Probe 13
ACV DCV
COM +
500.0 MV
One turn around aconductor carrying 250AAC
Figure 1
Figure 2
3000ARange
3000ARange
250A
®INS TRUMEN TS
CAT III1000V
300A
3000A
OFF
ONOL
FlexProbe ®
24-3002
ACV DCV
COM +
250.0 MV
®INS TRUMEN TS
CAT III1000V
300A
3000A
OFF
ONOL
FlexProbe ®
24-3002
Double the turns to doublethe output in low current applicationsor for higher sensitivity
250A
14 FlexProbe® - Flexible AC Current Probe
CHAPTER 5
MAINTENANCE
Warning• Formaintenanceuseonlyspecifiedreplacementparts.
• Toavoidelectricalshock,donotattempttoperformanyservicingunlessyouarequalifiedtodoso.
• Do not perform any service while the FlexProbe® is on any circuit.
• Toavoidelectricalshockand/ordamagetotheinstrument,donotgetwaterorotherforeignagentsintotheelectronicmodule.
• Alsoseewarningonpage2.
5.1 Changing the BatteryIfthepowerONindicator(greenLED)blinksordoesnotlightup,replacethebattery.
Disconnect the instrument from any source of electricity.
• To replace thebattery, open rear case, replacebattery and re-assemble.
• ThegreenLEDshouldgoonwhenthemoduleisturnedon.
5.2 Cleaning• Useasoftclothlightlydampenedwithsoapywater,thendrywith
adrycloth.
• Donotsplashwaterdirectlyontheinstrument.
• Donotusealcohol,solventsorhydrocarbons.
• Makesure thesensor,electronicmodule,andall leadsaredrybeforeanyfurtheruse.
FlexProbe® - Flexible AC Current Probe 15
Repair and Calibration
Toensurethatyourinstrumentmeetsfactoryspecifications,werecommendthatitbescheduledbacktoourfactoryServiceCenteratone-yearintervalsforrecalibration,orasrequiredbyotherstandardsorinternalprocedures.
For instrument repair and calibration:Youmust contactourServiceCenter foraCustomerServiceAuthorizationNumber(CSA#).Thiswillensurethatwhenyourinstrumentarrives,itwillbetrackedandprocessedpromptly.PleasewritetheCSA#ontheoutsideoftheshipping container. If the instrument is returned for calibration,weneed toknowifyouwantastandardcalibration,oracalibrationtraceabletoN.I.S.T.(Includescalibrationcertificateplusrecordedcalibrationdata).
Ship To: ChauvinArnoux®,Inc.d.b.a.AEMC®Instruments 15 Faraday Drive Dover,NH03820USA Phone:(800)945-2362(Ext.360) (603) 749-6434 (Ext. 360) Fax: (603)742-2346or(603)749-6309 E-mail:repair@aemc.com
(Orcontactyourauthorizeddistributor)Costsforrepair,standardcalibration,andcalibrationtraceabletoN.I.S.T.areavailable.NOTE: You must obtain a CSA# before returning any instrument.
Technical and Sales Assistance
Ifyouareexperiencinganytechnicalproblems,orrequireanyassistancewiththeproperoperationorapplicationofyourinstrument,pleasecall,mail,faxore-mailourtechnicalsupportteam:
ChauvinArnoux®,Inc.d.b.a.AEMC®Instruments 200FoxboroughBoulevard Foxborough,MA02035USA Phone:(800)343-1391 (508) 698-2115 Fax: (508)698-2118 E-mail: techsupport@aemc.com www.aemc.com
NOTE: Do not ship Instruments to our Foxborough, MA address.
16 FlexProbe® - Flexible AC Current Probe
Limited Warranty
TheFlexProbe®iswarrantedtotheownerforaperiodofoneyearfromthedateoforiginalpurchaseagainstdefectsinmanufacture.ThislimitedwarrantyisgivenbyAEMC®Instruments,notbythedistributorfromwhomitwaspur-chased.Thiswarrantyisvoidiftheunithasbeentamperedwith,abusedorifthedefectisrelatedtoservicenotperformedbyAEMC®Instruments.
For full and detailed warranty coverage, please read the Warranty Coverage Information, which is attached to the Warranty Registration Card (if enclosed) or is available at www.aemc.com. Please keep the Warranty Coverage Information with your records.
What AEMC® Instruments will do:Ifamalfunctionoccurswithintheone-yearperiod,youmayreturntheinstrumenttousforrepair,providedwehaveyourwarrantyregistrationinformationonfileoraproofofpurchase.AEMC®Instrumentswill,atitsoption,repairorreplacethefaultymaterial.
REGISTER ONLINE AT:www.aemc.com
Warranty Repairs
What you must do to return an Instrument for Warranty Repair: First, request aCustomerServiceAuthorizationNumber (CSA#) by phoneorbyfaxfromourServiceDepartment(seeaddressbelow),thenreturntheinstrumentalongwith thesignedCSAForm.Pleasewrite theCSA#on theoutsideoftheshippingcontainer.Returntheinstrument,postageorshipmentpre-paidto:
Ship To: ChauvinArnoux®,Inc.d.b.a.AEMC®Instruments 15FaradayDrive•Dover,NH03820USA Phone:(800)945-2362(Ext.360) (603) 749-6434 (Ext. 360) Fax: (603)742-2346or(603)749-6309 E-mail:repair@aemc.com
Caution:Toprotectyourselfagainstin-transitloss,werecommendyouinsureyourreturnedmaterial.
NOTE: You must obtain a CSA# before returning any instrument.
07/08
99-MAN100272v6
Chauvin Arnoux®, Inc. d.b.a. AEMC® Instruments15FaradayDrive•Dover,NH03820USA•Phone:(603)749-6434•Fax:(603)742-2346
www.aemc.com