Cargo Tank Monitoring System with Pressure/Temp
General Information
Principle of operation
The radar sensor gauge is the best version of radar level gauge for marine tankers which has been made based on the longtime field experience & stopless research and development. It is designed solely for measuring the distance, level, volume
and reflectivity of liquids, pastes, slurries, and solids. Radar sensor can form part of an overfill protection system as defined
in WHG if ordered with the the appropriate options. Radar sensor is a level metter based upon FMCW radar. It is used for
measuring Level, Volume, distance to surface, reflectivity of liquids, pastes and slurries. Radar sensor is a newgeneration
level meter with a wizard-driven setup, fully-potted electronic subassemblies, an online help functions. Radar sensor gauge
safety module located in the cargo control room by means of the pressure and temp.
The radar sensor gauge is Radar Type level transmitter using a frequency
modulated continuous wave(FMCW) electromagnetic signal to measure the
distance between its antenna and the cargo tank content surface(ullage).
Frequency difference between transmitted and received wave is directly
proportional ullage. An adapted data processing is able to be calculated. The
micro wave signal issued from the antenna is directly processed, then we can
obtain the distance between antenna and liquid surface(ullage).
Application
Ship's Radar tank gauging in storage vessels.
Level measurement in processing vessels, reactors, blenders, scrubbers
and mixers.
Hygienic radar systems for distillation and purified water vessels even with
water sprays.
Interfaces on some special applications/liquids.
Monitoring handling of high temperature molten products, inc metals
minerals and coke products.
www.marsen.co.kr
RADAR LEVEL TRANSMITTER
05
www.m
arsen.c
o.k
r
CARGO-2000 (Radar Type)
Technical Data
Measuring rangeAccuracy(at reference conditions)
Repeatability
Measured value resolution
Operating mode
Beam angle
Local Display
Hazardous locations
Ambient temperature(signal converter)
Flange temperature
Ingress protection(signal converter)
Media
Physical properties
Dielectric constant
Product limitations
Process temperature
Signal converter
Flange system/antenna
Gaskets
Process temperature
Powered by
Protocols
Current output
Ex approvals
IACS approvals
0~40m / 0~132ftup to 20m / 66ft 2mm / 0.08
0.5% error of measurement
0.1mm / 0.04
FMCW[Frequency Modulated Continuous Wave]24Ghz
5
Graphical LCD with to touch screen
Intrinsically safe, zone 0, 1, 2
Temperature classes : T6 T1
Explosion groups : llA llC
-40 +200 / -40+160
-40 +200 / -40+390
opt iona l -60 +250 / -75 +480
lP67
Measures all liquids and solids
no effect on measurement results
1.5
liquid ammonia, liquid hydrogen, liquid helium
unrestricted(but be aware of ambient and flange temperatures)
stainless steel 316L
stainless steel 316L[1.4404][standard]or 3% Molybden Mo
FPM[Viton], Kalrez 6375[others optional]
DIN 2501 DN 125 / PN 16[standard]
DC 24V
HART
4~20mA passive
Intrinsically safe according to ATEX
DNV, ABS, GL, LR, BV, CCS, KR NK, RINA[pending]
-
7/29/2019 Marsen Catalog v6.0
4/26
07
www.m
arsen.c
o.k
r
06
www.m
arsen.c
o.k
r
Cargo Tank Monitoing System with Magnetic Float CARGO-2000 (Magnetic Float Type)
General Information Specification
VALUE
Detection unit
Measuring range
Accuracy
Material
Ex. Proof
Enclosure
Indication
Out put
Ambient temp
Specific gravity
Power
SPECIFICATIONAlarm inside measuring range (0 to 35meter)
Level: 0~35 meter users request
Temp: PT100 or PT1000
Level: 0~35 meter (or users r equest)
Temp: basic 3 point -30 to 200 (expand available)
Level: 10mm (option 5mm)
Temp: +/- 1.0
SUS 304/ SUS 316 / PTFE
intrinsicallay safety Ex ia C T6
IP 56 & IP 67 & IP 68
wide lcd display
7- segment available
Level: 5mm indication (1mm indication option)
Total 0 to 35,000mm
& alarm condition display
Temp: 3 point (more point option)
or available 0 -999 range
4~20mA analog signal
RS 232 / RS 422 / RS 485 (option)
contact output (for outer alarm)
-25 to 75
min 0.65 max 1.5
AC 110/220 & 50/60Hz
The CARGO-2000 is the best version of magnetic float level gauge for marine tankers which has been made based on thelong time field experience & stopless research and developments.
It is a magnetic float type tank level gauge featuring an S.O.S (System One Sensor) that tank level, temperature, vapour
pressure as well as issuing an alarm when limits are exceeded.
This system is widely suitable for measurement and control of cargo liquid levels at crude oil tanker, coaster tanker, product
carriers and chemical carriers etc.
A key feature of the tank monitoring system is its easy of handling, because the sensors in the detector are flexible, it can be
lifted up by hand without the need to enter tanks, even in the case of cargo tanks of all liquid carrier.
All system is automatically operation and easy installation.
Features
Compact & cost saving design
Reliable Reed Switch
3 Point Temp sensor available
Microprocessor based operating program
Easy widely spread LCD display
Patent product in case of sensorAll product & liquid measuring
Application
TANKER
CHEMICAL TANKER
OFFSHORE
CRUDE OIL
CHEMICAL
SEA WATERFRESH WATER
GAS STATION
OIL or LIQUID A STORING PLACE
FRESH WATER
GAS STATION
Component
Controller
- Wide LCD panel
- 7-Segment available
- Power supply
- Signal Converter
Barrier Cabinet
- Intrinsically Safety Barrier
Sensor
- Float Level Sensor
- Temperature sensor 3 point
- Environmental Housing
World reading company inside measuring and control
www.marsen.co.kr
-
7/29/2019 Marsen Catalog v6.0
5/26
09
www.m
arsen.c
o.k
r
08
www.m
arsen.c
o.k
r
Independent Type Cargo Tank High/Overfill Alarm System HAI-2000 (Magnetic Float/Capacitance Type)
General Information Specification
Magnetic Float TypeValve Specification
Sensor type
Sensor material
Max pressure
Measuring range
Working temp
Accuracy
Enclosure
Ex proof
Contact
Temp accuracy
Specific gravity
Nominal range
single / dual / add to temp
SUS 316
5 Kgf/cm2
0~2,500mm users request
-20 ~ +150
Level: 10mm (option 5mm)
IP 68
Ex ia C T6
spst or users request
+/- 1
0.6 above
95% at volume (high)
98% at volume (overfill)
Capacitance TypeValve Specification
Model
Conn. Size
Material
Power Supply
Output
Operating Temp.
Protection
Safety
CLS-420
JIS 5K 100A (standard)
Housing-SCS13
Flange-SUS304 or SUS316
Sensor Probe-SUS316L/PTFE
18 to 28 VDC
4~20mA current loop with
8mA-no alarm
16mA-alarm
AMB-25 to 70
LIQUID-40 to 150
IP56 over
Ex ia C T6
The HAI-2000 is the best version of magnetic float alarm and capacitance type for marine tankers which has been made
based on the long time field experience & stopless research and developments. It is a magnetic float type tank high overfill
alarm sensor featuring an stable function. This signal is connected to alarm modulator through safety barrier. The 95% of
volume is normally for high alarm and 98% of volume is normally overfill alarm. A test lever is provided for manually functional
test to check integrity of high level alarm system before cargo loading. In hazardous areas, this equipment should be used in
conjunction with an intrinsically safety barrier. Generally our made other system can be add up for low costs.
Features
Simultaneous measurement of level alarm and high
temperature alarm by one unit.
Designed for all kind of liquid.
Most advanced electric technology.
for high reliability and durability.
Patent product in case of sensor.
Simple for construction.
Certified by major certifying authorities.
Application
TANKER
CHEMICAL TANKER
LPG TANKER
CRUDE OIL TANKER
PRODUCT OIL TANKER
LNG TANKER
This systems are used for the level alarm in cargo tanks
of all kinds of oil & chemical carriers.
Component
Controller
- LED panel
Barrier Cabinet
- Intrinsically Safety Barrier.
Sensor
- Float Level Sensor/ Capacitance Level Sensor
- Temperature sensor (Option)
World reading company inside measuring and control
www.marsen.co.kr
-
7/29/2019 Marsen Catalog v6.0
6/26
Components of System
11
www.m
arsen.c
o.k
r
10
www.m
arsen.c
o.k
r
Ballast & Draft Level Gauging System BAL-2000 (Pure Pneumatic Type)
Principle of operationThe principle of operation is based on the measurement of the hydrostatic pressure by providing a constant low flow of air
or neutral gas into a probe which opens at the tank bottom.
The flow regulator is discharged through the purge mouth at the tank bottom and ensure a constant at the end of the
sounding pipe in the tank irrespective of the supply pressure.
Gauge saver is used for protecting the level indicator against over pressure.
The blowing valve in sued for isolation from other channel without any influence.
The air supply valve in used for sending the full air pressure through the signal line for cleaning purposes.
The output pressure of this constant flow regulator (Corresponding to the hydrostatic pressure at the bottom of the
sounding pipe) is connected to the level indicator.
The indicator and constant flow regulator are built in interconnecting assembly ready for panel mounting.
Features
Liquid level of measuring depth pressure is indicated for direct r eading, and then the high precision is achieved.
The construction is simple and the handling and maintenance is easy.
Since no electricity is used, the explosionproof measures is not necessary.
Included stop valve, other pressure is no need for line leakage test.
Application
Ballast tank remote reading
Draft remote readingHeeling and trim remote reading
Fuel oil tank remote reading
Cargo oil tank remote reading
All liquids even viscous ones
(molasses, bitumen, etc.)
World reading company inside measuring and control
www.marsen.co.kr
DOUBLE CHECK VALVE
- MODEL : DCV-
- Body material : Nabal brass
- Connection size : JIS 5K or 10K Flange
- Working pressure : Max 10 kg/cm2
FLOW REGULATOR
- MODEL : FRU-200
- Body material : AL
- Air supply : 4.5 kg/cm2
- Flow rating : 10~80 NL/H
- Blowing pressure : 4.5 kg/cm2
GAUGE SAVER
- MODEL : GSU-200
- Body material : AL
- Differential : Below 0.01 kg/cm2
LEVEL INDICATOR
- MODEL : PLG-200
- Dimension : 144 144 55.5mm
- Accuracy : 1.5% of Full Scale
- Scale Range :
- Working Temperature
Gas : -20~65
Fluid : -20~80
3 WAY COCK- MODEL : MCK-200- Fluid : Air/Inert Gas- Operating Pressure : 0 to 1.0 MPa
- Ambient and Fluid Temperature : -5 to 60(No Freezing)
- Effective Area : 19 sqmm- Lubrication : Not Required(Use Turbine Oil Glass 1 ISO VG32, lf Lubricated)
- Port Size : 1/4
Specification
VALUE
System type
Work temperature
Signal pipe
Operating air pressure rating
Flow rating
Range
Accuracy
SPECIFICATION
one line air purge system
-30 ~ 70
OD 8mm
4~7 kg/cm2
10 ~ 80 Nl/hour
1 to 40 meter
0.5% os F.S(option)
1.0% os F.S
Air Purge Type Remote Level Gauging System
-
7/29/2019 Marsen Catalog v6.0
7/26
Components of System
13
www.m
arsen.c
o.k
r
12
www.m
arsen.c
o.k
r
Ballast & Draft Level Gauging System BAL-2000 (Electric/Pneumatic Type)
Principle of operation
Specification
VALUE
System type
Work temperature
Signal pipe
Operating air pressure rating
Flow rating
Range
Power supply
Output
Accuracy
SPECIFICATION
one line air purge system
-30 ~ 70
OD 8mm
4~7 kg/cm2
10 ~ 80 NI/hour
1 to 40 meter
16 to 32 VDC
4 ~ 20mA 2 wire system
0.5% os F.S (option)
1.0% os F.S
The principle of operation is based on the measurement of the hydrostatic pressure by providing a constant low flow of airor neutral gas into a probe which opens at the tank bottom.The output pneumatic signal of the modulator is fed into P/I converter and is changed to electric signal (4~20mA) in 2 wireby P/I convertor.The electric output signal(4~20mA) can be connected to C.R.T display cargo system, Digital indicator, analogue typeindicators, etc. or a combination of these system.
FeaturesLiquid level of measuring depth pressure is indicated fordirect reading, and then the high precision is achieved.The constr uction is simple and the handlin g a ndmaintenance are easy.4~20mA output signal 2-wires.Blowing valve is select type(change over type).So blowing is very easy.Included stop valve at air purge head, other pressure isno need for line leakage test.
ApplicationBallast tank remote readingDraft remote readingFuel oil tank remote readingAll liquids even viscous ones (molasses, bitumen, etc.)
World reading company inside measuring and control
www.marsen.co.kr
P/I CONVERTER
- MODEL : PHDH-200
- Excitation(Calibration Voltage) : DC 24V
- Excitation : DC 11~28V
- Output : 4~20mA (2wire)
- Accuracy(RSS) : 0.5% F.S
- Compensated Temerature Range : 0~70
- Operating Temperature Range : -20~80
- Thermal Effect on Zero : 0.03% F.S/
- Thermal Effect on Span : 0.03% F.S/
ANALOGUE INDICATOR
- MODEL : MAG-200
- Input : 4~20mA
- Internal resistence : 10 ohm
- Indicating accuracy :
High value of 1.0 Full Scale
- Dimension : 110 110
- Color : Black
Air Purge Type Remote Level Gauging System
-
7/29/2019 Marsen Catalog v6.0
8/26
15
www.m
arsen.c
o.k
r
14
www.m
arsen.c
o.k
r
Tank Level Gauging System BAL-2000 (Electric Pressure Type)
Principle of operation Specification
VALUE
Principle
Output
Accuracy
Supply voltage
Material
Measuring cell
Explosion protection
Operating temperature range
SPECIFICATIONConverting hydrostatic pressure of a column of
liquid into a level-L-proportional signal.
4~20mA
0.2% of F.R
12~30V DC
Diagram-AI2O3aluminum oxide ceramic probe
housing-SUS 316 Seal-viton
oil-free dry sensor
Ex ia C T6
-20~100
The ceramic measuring cell is oil-free, I.e the process pressure acts directly on the rugged ceramic diaphragm of pressure
transmitter and causes it to move by a max, 0.025mm.
A pressure-dependent change in capacitance is measured by the electrodes in both the ceramic substrate and the
diaphragm.
The measuring range is determined by the thickness of this ceramic diaphragm.
Features
With is high electrical and mechanical stability, pressure
transmitter fulfills all plant construction standards.
Ceramic measuring cell-extremely resistant to overload,
alternating loads and aggressive media.
Support cable with hard-wearing conical seal on the
probe tube and climatic protection in the pressure
compensation tube.
Potted electronics with 4-20mA output signal andintegrated overvoltage protection.
Certified for hazardous area Ex ia C T6.
Application
Ballast tank remote reading
Draft remote reading
Fuel oil tank remote reading
Wast waters, wells, locks, revers etc.
World reading company inside measuring and control
www.marsen.co.kr
-
7/29/2019 Marsen Catalog v6.0
9/26
17
www.m
arsen.c
o.k
r
16
www.m
arsen.c
o.k
r
Pressure Monitoring System VIP-2000
General Information Specification
VALUESensor type
Sensor material
Max pressure
Measuring range
Working temp
Accuracy
Enclosure
Ex proof
Signal
Gas kinds
Display
SPECIFICATIONCeramic (silicon) type pressure transmitter
SUS 316L/PTFE
up to over pressure (range X2)
-500~500mbar (or users request)
-20 ~+150
F.S +/- O.5% (or users request F.S +/- 0.25%)
IP 68 in case of housing
Ex ia C T6
4~20 mA analog signal
oil/chemical
LCD or 7-Segment display Including alarm condition
The "Cargo Tank Ullage Space Monitoring System including High & Low Pressure Alarm" (VIP-2000) is newly required by
IMO SOLAS 74, Chap. -2 Req. 59 become effective on 1. July 1998 for preventing serious deformation of the tank
structure from such over/under pressure in case of P/V valve failure.
The pressure monitoring system is designed for cargo tank & manifold pressure monitoring for any number of tanks.
The ceramic measuring cell is very strong about environmental condition.
Also this system can be reduce a calibration fee compared with P/V valve a period calibration because not need a separate
that local area can be a calibration.
Generally our made other system can be add up for low costs.
Features
Intrinsically safety detecting is applicable to all of
inflammable.
Ceramic measuring cell- extremely resistant to overload,
alternating loads and aggressive media.
Each sensor module pressure display
Patent product in case of sensor
Certified for hazardous area ex proof
Certified by major certifying authorities
High accurate reading vacuum and press figure
Application
TANKER
CHEMICAL TANKER
CRUDE OIL TANKER
PRODUCT OIL TANKER
If user's installed it's system instead of P/V valve, get in a
profit both maintenance and cost of certificate
System Principle
The intrinsically safety type cargo tank vapour pressure monitoring system is intended for cargo tank pressure and vacuum
pressure monitoring.
The ceramic measuring cell is oil-free, ie, the precess pressure acts directly on the rugged ceramic diaphragm of pressure
transmitter & causes it to move by a max pressure.
The electrical signals from the pressure transmitters on deck are connected to zener barrier in the in the monitoring cabinet
equipped with pressure alarm lamp, buzzer and pressure figure indicator in the cargo control room.
If expanded system, have a easy expanded designed.
World reading company inside measuring and control
www.marsen.co.kr
-
7/29/2019 Marsen Catalog v6.0
10/26
Main Component
19
www.m
arsen.c
o.k
r
18
www.m
arsen.c
o.k
r
Vapour Emission & Control System VECS-2000
General Information Specification
System
Press. Transmitter
Oxygen sensor
Main power supply - AC 110/220V, 50~60HzSystem power - DC 24V
Air supply - 4~7 bar
Range - 0~200mbar
Power supply - DC 24V
Output - 4~20mA
Range - 0~25% O2
Power supply - DC 24V
Function -Accept horn, Accept flash, Test function
This system is intended for measuring oxygen gas content analyzing the waste VOSs gas contents and manifold lines form
Oil/Chemical Tanker.
All tanker and chemical tanker should be install from19. May. 2005 according to IMO MSC/Cire 585.
All necessary parts are intrinsically safety certified product.
The Sampling Cabinet in steel case is installed on deck nearby the vapur manifolds and the controller is mounted in the
cargo control room. (C.C.R)
Features
Intrinsically safety detecting is applicable to all of sensing
zone.
Material is reliable to secure body.
Setting figure adjustable in factory.
Program Operating Control (P.O.C) Type is easy install
and small size.
Selectable vapour oxygen contents measure.
Another gas can be measure by sensor tip replace only(option).
Anot her gas, pre ssur e a nd temp erat ure can be
expanded easy.
Offshore terminal interface function.
Operation principle
The system has fourth sample points and only one sample
is directed and monitored individually through selecting
valve at the time.
The sa mpling cabinet has a include oxygen sensor,
vapour pressure transmitter and nonflow sensor with
intrinsically safety certified.
Measuring oxygen, vapour pressure and non-flow signal
send to controller through I.S barrier.All signal is display within wide LCD as to figure and alarm
condition.
If alarm is occur, controller sound a buzzer, flickering and
external signal.
World reading company inside measuring and control
www.marsen.co.kr
-
7/29/2019 Marsen Catalog v6.0
11/26
21
www.m
arsen.c
o.k
r
20
www.m
arsen.c
o.k
r
Fixed Gas Monitoring & Alarm System BGAS-2000
Principle of operation
The fixed gas monitoring system(BGAS-2000) is and automatically scanning Gas sampling system permanent installed for a
number of sampling points. The BGAS-2000 are common for all sampling points, allowing the use of high quality gas
detectors with good accuracy. A gas monitoring is taken from each sampling point in turn, according to the sampling
sequence, and transported through the sampling pipe to the gas detectors. The sampling time for each points is individually
adjustable corresponding to the pipe length of each sampling point. This gives an optimally short cycle time.
The fixed gas monitoring system(BGAS-2000) is intended for detection of explosive and toxic gases in cofferdams, pipe
tunnels, stools, ballast tanks, slop tanks and other areas adjecent to cargo tanks.
A pump room installation is normally a separate system.
The BGAS-2000 is designed to meet the requirements of IMO/SOLAS and classfication rules.
Features
Intrinsically safe sample cabinet
Up to 48 sample points
Expandable in the field with plug-in solenoids
Auto and manual purge cyclesAuto shutdown and alarm on point flow failure
Multiple remote displays on multi-drop network
All sensor locations displayed on screen
Application
Sampling of the ballast tanks and void spaces in done
by our sampling cabinet.
The unit is powered equally by 110 or 220 VAC.
The system is connected to ships computer network forviewing, logging and control of the system from any
authorized computer on the network.
World reading company inside measuring and control
www.marsen.co.kr
Specification
VALUE
Power supply
Pump capacity
Gas detectors
Sampling points
Suction pipes
Outputs
Installation accessories
Option
SPECIFICATION
110~220 VAC (50~60Hz), 2A
151/min
Up to 4 pieces (HC, O2, H2S etc)
Maximum 48 with or without counter pressure
OD 8 or 10, ID approx. 6
6 relays with 2 switching 5A contacts
each standard or custom defined
Flame traps, shut off valves, filters, cones, etc.
Printer(RS232), NMEA protocol(RS485),
Pre-suction pump 151/min,
1~4 Repeater units, pump redundancy,
other special arrangements
Components of System
System Example
-
7/29/2019 Marsen Catalog v6.0
12/26
23
www.m
arsen.c
o.k
r
22
www.m
arsen.c
o.k
r
Oil Discharge Monitoring Equipment
General Information
The ODM-2000 has an oil discharge monitoring and control system installed, incorporating an approved oil content meter
with a starting interlock and an automatic overboard valve control system. The system is fully intrinsically safe using optical
fibers. Automatic cleaning is achieved by a pneumatic actuated wiper, all part in contact with the fluid are corrosion proof for
long-life in harsh environment. A self-calibration and washing system eliminates most of the mainenance. The system is a
high quality product and the components are designed for obtaining long lifetime in a rough environment.
Features
The measuring range is 0-1000ppm
Easy to operate as it is a minimum of button to press and self explanatory menus
Robust, easy to install and easy to maintain
A unique self-cleaning feature, making manual cleaning virtually unnecessary.
Intrinsically safe type, DP transmitter
Short response time(15sec)
Insensitive to ships motion and vibration
Flowmeter working by differential press.
IMO RES. MEPC. 108[49]
Input information : PPM, Flow Rate, Ship's Speed, GPS(Latitude & Longitude), Date & Time.
Starting interlock
Discharge Valve Control
Output Information(Displayed and printed) : L/N.M, Total Quantity, Date & Time, PPM, GPS(Latitude & Longitude)
World reading company inside measuring and control
www.marsen.co.kr
ODM-2000
Specification
NAME
Oil content
Method of communication
Discharge flowrate
Log speed
Gps
Discharge valve
Valve position
VALUE
0 to 1000ppm
Max. 1,225m3/h
21knots max.
SIGNAL
Display
Current Loop
4-20mA
Impulses
NMEA0183
Dry contact
Dry contact
Controller and oil content meter power supply : 220V-60Hz or 110V-50Hz
Motor/pump power supply : 440V-60Hz or 380V-50Hz, tree phase
Ambient temperature : 0~+55
roll and pitch : 22.5 respecting normal installation specifications
Humidity : 95%RH at the most at 55
Vibration : 2-13.2 Hz amplitude+1mm
Input and output signals
OIL CONTENT METER HYD. PACAGE
CONTROLLER
-
7/29/2019 Marsen Catalog v6.0
13/26
25
www.m
arsen.c
o.k
r
24
www.m
arsen.c
o.k
r
Temp Monitoring System
General Information
The TEMP-2000 has been specially developed in conformity with SOLAS 2000 Amendments Chap -2 Reg 4 amended
for protecting the cargo pump room in tanker.
It consists of temperature sensors, safety I.S barriers and temperature monitoring unit having digital display and alarm
status.
Cargo pumps, Ballast pumps and stripping pumps, installed in cargo pump rooms and driven by shift passing through
pump room bulkheads shall be fitted with temperature sensing devices for bulkhead shaft glands, bearings and pump
casings. The continuous and audible and visual alarm shall be automatically effected in the cargo control room or the pump
control room.
Our system is installed special program in temperature measuring and control only.
If you spread or special purpose request, will be convert to fast fitted your request.
Features
Easy installation
Micro processor type controller
Long life sensor
Digital displayHigh, Low and another setting available
Widely strong interface function
Most advanced electric technology for high reliability and
durability
Application
The pumps temperature monitoring & alarm panel gives
an audible, visible alarm with digital display.
The individual external sound and visual alarm device
may be prepare in accordance with user's requestspecial option.
Another system like as P/R bilge alarm, gas alarm may
be prepared with our system if user's request.
World reading company inside measuring and control
www.marsen.co.kr
TEMP-2000
Specification
VALUESensor type
Sensor material
Max measuring temp
Measuring range
Working temp
Accuracy
Enclosure
Ex proof
Signal
Fault
Installation
SPECIFICATIONRTD/ TC/ SEMICONDUCTOR
SUS 316/VITON
UP TO 600
NOMINAL 0~200
-30~ +80
+/- 1.0 (or USERS REQUEST F.S +/-0.5 )
IP 56 IN CASE OF HOUSING
Ex ia C T6
RTD/TC/or 4~20mA ANALOG SIGNAL
LINE BREAK/SHORT MEASURING
BEARING1, BEARING2, INTERMEDIATE BEARING
CASING, BULKHEAD SHAFT GLAND
FITTING MOUNTING
-
7/29/2019 Marsen Catalog v6.0
14/26
-
7/29/2019 Marsen Catalog v6.0
15/26
Specification
29
www.m
arsen.c
o.k
r
28
www.m
arsen.c
o.k
r
Valve Remote Control System
General Information
The VRC-2000 is designed for position indication and
electro-hydraulic remote control of hydraulically actuated
valves.
The principle of the VRC-2000 is that pressurized oil,
generated by the power pack, is used to open or close the
valve by means of the solenoid controlled actuator.
Our wide array of valve remote control systems includes
hydraulic, pneumatic, electric and electro-hydraulic
options.
Pneumatic/Hydraulic Actuator
Source : Pneumatic or Hydraulic
Acting : Single or Double
Connection : G 1/2"
MAX press : 10BAR (Pneumatic) 350 BAR(HYD)
MIN PRESS : 4BAR (Pneumatic) 80 BAR(HYD)
Connection valve : Butterfly or Ball
Indication : option -Use : Ballast Tank
Easy to install & Simple operating.
Fast delivery time & low price.
At least maintenance & Long life.
Electric actuator
Source : AC220/110V 50/60Hz
Valve : Butterfly of Ball
Enclosure : IP 68
Size : 40~100A
Manual : Available
Indication : Visual indication
Use : Dry space
World reading company inside measuring and control
www.marsen.co.kr
VRC-2000
VALUE
Certified to
Ambient temperature
Liquid temperature
Protection class
Normal voltage
Normal current
Measuring voltage
SPECIFICATION
Class Drawing
-25 ~ +70
-20 ~+70
IP56, IP65, IP68
4.6V to 30V DC
Unswitched < 0.5A
switched > 2.0A
AC 110/220V
-
7/29/2019 Marsen Catalog v6.0
16/26
31
www.m
arsen.c
o.k
r
30
www.m
arsen.c
o.k
r
Water Ingress Alarm System
General Information
This system comprises of alarm monitoring cabinet, Intrinsically safety Barrier and types capacitance liquid detectors
installed in each cargo holds and compartment.
Our model provide our customer with suitable method for new ships and existing ships.
Features
Intrinsically safety detection can be applicable to all of
inflammable area, if required.
No fault and any mechanical moving device for sensor.
No moving part and reliable sensing system.
A lot of any number of detecting points.
Complete dust-proof and waterproof (IP68 - 5bar
according to IEC 60529)
Available for the overriding device for which the alarm
can be de-activated.
No electrical and mechanical corrosion.
Easy maintenance and installation.
Operating by microprocessor.
Passed the EMI, EMC testing completely.
Rules & Regulation
SOLAS X /12 & X /13
IMO RES MSC 145(77)
IACS SC180
Technical specification
Main Power : AC 110/220V
Emcy Power : DC 24V
Max. detecting points : 80 points
Ambient Temp' : -25 ~ 70
Sensor Housing Material : SUS 316
Accuracy : +/- 5mm available
Sensor enclosure: IP68
Sensor Ex. Grade : Ex ia B T4
Indicating system: LED
Pressure : 5 bar
Time delay : abt 10 second (by microprocessor control)
I.S barrier Grade : [Ex ia] C
Overriding point : Max. 48 points
Alarm sound : Dual type alarm sound.
Interface & Simulation : RS 485 (422) & Simulation test
available
World reading company inside measuring and control
www.marsen.co.kr
WIA-2000
Specification
VALUESensor type
Sensor material
Max pressure
Working temp
Accuracy
Enclosure
Ex proof
Signal
Fault
Level kinds
Installation
SPECIFICATIONPressure / Capacitance / Electrode / Float
SUS 304 / SUS 316
MAX 5 KG/cm2
-10 ~ +60
+/- 5 mm
IP 68 in case of sensor
Ex ia C T6
4-20mA Analog Signal
Line break / Short measuring / Earth
Liquid / Coal / Sea water / Chemical / Solid etc
Wall mounting / Penetration mounting
-
7/29/2019 Marsen Catalog v6.0
17/26
33
www.m
arsen.c
o.k
r
32
www.m
arsen.c
o.k
r
De Watering System
General Information
This system (WIP-2000) is adapted in SOLAS Reg XZI/13 for Bulk Carrier, is designed and developed in compliance with
IACS SC 180 rule requirements.
This system is for discharging of water from ballast tank or forward dry spaces to overboard remotely.
This system is available several method like as Electro, Pneumatic, Hydraulic operating.
Controller
Source : AC 110V/220V & 50/60Hz
Material : SS400
Function :
1) Alarm function
2) Valve operating function (open/close)
3) Power fail (option)
4) Power on/off
5) Horn/Outdoor lamp (option)
6) Digital or Mimic type
Pneumatic/Hydraulic Actuator
Source : Pneumatic or Hydraulic
Acting : Single or Double
Connection : BSPT 1/4"
MAX press : 10BAR (Pneumatic) 350 BAR(HYD)
MIN PRESS : 4BAR (Pneumatic) 80 BAR(HYD)
Connection valve : Butterfly or Ball
Indication : option -Use : Ballast Tank
Easy to install & Simple operating.
Fast delivery time & low price.
At least maintenance & Long life.
Hydraulic Power Pack
Source : AC 220V/60HZ
MAX. Prexx : 120 BAR
Port : 2 Port
Enclosure : IP 68
EM'CY operating : YES (BY HAND PUMP)
Weight : 35KG
Option : Lock indication. Pneumatic operating
World reading company inside measuring and control
www.marsen.co.kr
WIP-2000
Electric actuator
Source : AC110/220V 50/60Hz
Valve : Butterfly of Ball
Enclosure : IP 68
Size : 40~800A
Manual : Available
Indication : Visual indication
Use : Dry space
Major Function
F.P.T TANK Discharge
Bosun store discharge
Valve open/close indicating
Direct/Reverse operation
Another panel available
Specification
VALUE
Certified to
Ambient temperature
Liquid temperature
Protection class
Normal voltage
Normal current
Measuring voltage
SPECIFICATION
Class Drawing
-25 ~ +70
-20 ~+70
IP56, IP65, IP68
4.6V to 30V DC
Unswitched < 0.5A
switched > 2.0A
AC 110/220V
-
7/29/2019 Marsen Catalog v6.0
18/26
35
www.m
arsen.c
o.k
r
34
www.m
arsen.c
o.k
r
General Information
This system (TIN-2000) has a function monitoring and measuring for inclino and tilt by digital automatic program.
Also this system have a function like as digital display, alarm warning, output signal, interface etc.
This system is use for construction, ship's building, ship, offshore, crane etc.
TIN-2000 may be match several machinery and system like as heeling control system in case of container ship, level
gauging system in case of ship's F.O & D.O tanks etc.
All control is automatic control by program but in case of emergency control and measuring, may be convert to manual
mode.
This system is prepare wide range like as 5, 30, 60, 90, 180 and user's request.
And all direction is use for from left to right and front to rear or side to side, Its system is measuring to 16 channel basically.
World reading company inside measuring and control
www.marsen.co.kr
Auto Heeling with Inclinometer System
Specification
Auto heeling with inclinometer system (TIN-2000-P)
VALUE
Sensor type
Direction
Measuring degree
Display degree
Working temp
Accuracy
Enclosure
Max channel
Output signal
Output alarm
Source
Alarm setting
SPECIFICATION
Analog or Digital type
All direction (basic 2 direction)
1 , 2 , 3 , 5 , 10 and user's request.
1 , 2 , 3 , 5 , 10 and user's request.
-20 ~ +60
F.S 1% (or User's request F.S 0.5%)
IP44(controller), IP56 (horn & lamp)
16 channel
4~20mA Analog signal
2 Channel contact (widely available)
AC 110V/220V, 50~60Hz or DC 24V
User's request (basic alarm 2 point)
Specification
Anti heeling with inclinometer system (TIN-2000-A)
VALUE
Model
Main power
Accuracy
Response time
Operating temperature
Operating humidity
Measuring degree
Ingress Protection
SPECIFICATION
TIN-2000-AH
AC 100~240V, 1 50/60 Hz
1.5% F.S
1.0 sec.
0~45
25~90% RH(NO CONDENSATION)
1 , 2 , 3 and user's request.
IP44
VALUE
Model
Use voltage
Max. current
Casing material
Operating temperature
Ingress Protection
SPECIFICATION
TIN-2000-AL
DC 24V
0.480A
SUS 304
-25 ~50
IP56
Auto Heeling with Inclinometer System (TIN-2000-P)
Anti Heeling with Inclinometer System (TIN-2000-A)
TIN-2000
-
7/29/2019 Marsen Catalog v6.0
19/26
37
www.m
arsen.c
o.k
r
36
www.m
arsen.c
o.k
r
Bridge Navigation Watch Alarm System (B-WATCH-2000)
World reading company inside measuring and control
www.marsen.co.kr
Dead Man Alarm System (E-WATCH-2000)
General Information
Dead Man Alarm System is designed to monitor bridge activity and alert the master or other qualified navigators if the bridge
becomes unattended.
The system first alerts the officer of the watch through local alarm indication at the bridge unit and, if he is not responding,
then alerts the master or other qualified officer.
Our Dead Man Alarm System conforms to the requirements of IMO resolution MCS. 128(75)
Performance standards for a Bridge Navigational Watch Alarm System (BNWAS) and the bridge class notations for "one-
man bridge operation".
General Information
Dead Man Alarm System should be equipped inside the engine room. The infrared rays sensor catches the on-duty crews
position and controller makes alarm for preventing them from nap/sleeping.
This aims on its work for prevending crews from the nap/sleeping for safe sailing.
This device is for neither catching the sleeping crew, nor making alarm to wake them up.
Operation Principle
System on/off (password protected)
Adjust system timers(password protected)
Audible and visual alarm indications
Keys for sound off and acknowledge of alarms
Selection of back-up navigator in duty
Call back-up navigator
Requirement
Operating temperature : -15 to +70
Maximum humidity : 96% no condensation
Supply voltage : 18 - 32 VDC. 5% ripple
Power consumption : 26W (typical)
Printer (option)
Type Approval by Ships Class
Specification
VALUE
Size (high wide depth)
Painting color
Cover
Body
Weight
Power supply voltage
Sensor
Start(Touch Screen)Alarm Buzzer
Extensin Buzzer
Contact point signal
(for the alarm Panel)
Material
Number of input
Number of output
SPECIFICATION
400 320 180(mm)
7.5 BG 7/2
SS400
SS400
8kg
Main AC 110/220V 50/60Hz, Emcy DC 24V
1~6points
1point1point
1~16point
1point
CONTROLLER
SENSOR ALARM BOX
-
7/29/2019 Marsen Catalog v6.0
20/26
39
www.m
arsen.c
o.k
r
38
www.m
arsen.c
o.k
r
World reading company inside measuring and control
www.marsen.co.kr
Ship's CCTV System (CCTV-2000)
Specification
Source : AC 220V/110V 50/60Hz
Camera is color type basic.
Camera indoor/outdoor type.
Camera rotator/static type.
Basic camera 4/8/16 installation.
If you can install Deck marine. Should be check IP
enclosure.
Cable should be sore mold cable.
Component
O2 Analyzer (IGO-200)
General Information
In our supply an O2 analyzer with continous reading and alarm will be included. There will be two alarms, low and high O2
content. The high alarm protects the tanks atmosphere against high O2 contents and the low alarm protects the unit stop
the henerator, so the operator can adjust the equipment to correct the O2 content. When the O2 content is too high the
inert gas purged to the atmosphere.
Specification
VALUE
Size (high wide depth)
Painting color
Material
Weight
Power supply voltage
External output signal
Alarm point
Signal
O2 sensor PointRange
SPECIFICATION
Size (high wide depth)
7.5 BG 7/2
SS400
5kg
AC 100~240V 50/60Hz
4~20mA(DC)
Low & High alarm
4~20mA(DC)
1 or 2 points0~5, 0~10, 0~25%
L.C.D MONITOR(16:9)
- Source : AC 200~240V 50/60Hz- Size : 19inch
DIGITAL VIDEO RECORDER(DVR)
- Source : AC 200~240V 50/60Hz
- D imension : 380 308 65(W D H)- Operating System : Embedded Linux
- Compression : MPEG-4
- Multiplexer Functionality : Triplex(Record, Playback,
and Network at same time)
CAMERA
- Pick up Device : 1/3" Color Sony Super Had CCDII
- Color System : PAL(811H 508V)
NTSC(768H 494V)- Horizontal Resolution : 380tv Lines
- Minimum Illumination : 0 Lux(20M Range) : LED ON
: 0.1 Lux(F/1.2) : LED OFF
- S/N Ratio : -45db 10%- Source : DC 12V
-
7/29/2019 Marsen Catalog v6.0
21/26
41
www.m
arsen.c
o.k
r
40
www.m
arsen.c
o.k
r
World reading company inside measuring and control
www.marsen.co.kr
Oil Mist Detector (OMD-200)
General Information
Oil mist detection system adopting newest microprocessor and intrared technology was designed for detecting oil mist
existence which may possibly happen in the air of both crank chamber of marine engine and such as environments, engine
oil pump, purifier room and other machine rooms etc. of the vessel.
Features
Fast response to notify of exceeding allowable limit.
Alarm in a potentially dangerous situation.
Easy to installation and maintenance
Not affected by oil condensation in the air and electrical interference.
Specification
VALUE
Measurable range
Accuracy
Alarm contact
Power sourceProtection degree
SPECIFICATION
0-2.2mg/L
0.5%
Free Contact
DC 24VIP54
Bilge Alarm System (BOA-2000)
General Information
The BOA-2000 is developed to get an sound & visible alarm for high level of pump room bilge well or engine room bilge well.
This system consists of bilge alarm controller, intrinsically safety barrier and level switch.
When the liquid level reaches a set point, a level switch or transmitter on the bilge well is acting and the alarm signal is given
to the controller through intrinsically safety barrier.
The audible and visual alarm on the alarm controller should be operated.
The level switches shall be modelling into three types float type, capacitance type and displacement type.
All sensor is reliable and strong function.
This system can be spread up to 500 units sensor sensing.
Generally our made other system can be add up for low costs.
Specification
VALUE
Sonnection
Set point
Accuracy
Max. PressureOver pressure
Min. Sp gr
Contact
Signal (4~20ma)
Enclosure
Ex-proof
Material
Source
CAPACITANCE TYPE
PF 3/4" STND
200 ~ 20,000mm
5mm
5 Bar7 Bar
0.5
Available
Available
IP 56 (option IP65)
Ex ia C T6
SUS304/SUS316
4~20mA
DISPLACEMENT TYPE
JIS 5K 100A STND
220~5000 mm
8mm
5 Bar7 Bar
0.85
Available
Available
IP 56 (option IP65)
Ex ia C T6
ALDC/SUS316
MAX 250V 15A
FLOAT TYPE
JIS 5K 50A STND
120~5000 mm
5mm
5 Bar7 Bar
0.85
Available
Available
IP 56 (option IP65)
Ex ia C T6
ALDC/SUS316
MAX 250V 0.5A
-
7/29/2019 Marsen Catalog v6.0
22/26
43
www.m
arsen.c
o.k
r
42
www.m
arsen.c
o.k
r
Valve Operating Viewer Controller
World reading company inside measuring and control
www.marsen.co.kr
V-CON
General Information
This device can be use a control at automatic control valve like as pneumatic and electric.
This device using purpose is control and degree like as open/close.
Pneumatic and Electric automatic control valve controller
Upper/Down or Rotary control.
Source : AC 110V/220V or DC 24V
User setting convert to easy by digital.
Valve open/close indication.
Temp, Press, Humidity, Flow,
Level Vibration, Iclinometer
Some valve control available.
3-Way valve control available.
Dimension : About 300 200 180mm
Weight : About 2.0 kg
Input
Temp Transmitter (4-20mA)
Temp Sensor (RTD, PT-100)Pressure Transmitter (4-20mA)
Diff. Press Transmitter (4-20mA)
Level Transmitter (4-20mA)
Level Resis Transmitter (Potentio meter)
Flow Transmitter (4-20mA)
Vibration Transmitter (4-20mA)
Ultrasonic Transmitter (4-20mA)
Gas Transmitter (4-20mA)
Magnetic Transmitter (4-20mA)
Opto Transmitter (4-20mA)
Output
Contact, 4-20mA (Option), RS-232 (Option)
Aux. Function
P/P Reducer & Control
E/P Converter
Specification
Control Fluids
Control Target
Ambient Temp'
Working Voltage
Air Press
Components
Aux. Function
Output
Option/Accessory
ETC
Air, Water, Oil
Temp, Press, Level, Flow, Gas, Inclino ETC
0~60
AC 110/220V 50/60Hz or DC 24V
4-7 kg/cm2 (Max. 10 kg/cm2)
Controller, Sensor, Actuator
Alarm, Valve Open/Close Percent
Contact, 4-20mA(Option), RS-232(Option)
Shelter, Digital Valve Positioner (VOV_420)
Integration System, Actuator, Alar
Control Valve
-
7/29/2019 Marsen Catalog v6.0
23/26
Marsen Portable Gauging SystemGeneral Information
45
www.m
arsen.c
o.k
r
44
www.m
arsen.c
o.k
r
Ullage Interface Detector (UTL-200) UTL-200
World reading company inside measuring and control
www.marsen.co.kr
Tankers shall be provided with an effective oil/water interface detectors approved by the administration.
And U.T.I shall be provided for a rapid and accurate determination of the oil/water interface in slop tanks and shall beavailable for use in other tanks where the separation of oil and water is effected and from which it is intended to discharge
effluent direct to the sea.
Features
High accuracy & Responsibility
Protect operator
Prevent environmental pollution
Easy construction
Easy operation & Maintenance
Operation Principle
Detecting a change in impedance using ultra sonic
technology.
Measuring the different voltage according to conductivity of
water.
Temperature measurement is obtained by the output voltage
of the built-in semiconductor element.
Specification
Accuracy of ullage, interface detection
Indication of level divided by ullage and interface
Tape length
Tape graduation
Tape resolution
Tape accuracy
Diameter of probe
Minimum detectable level
Ambient temperature range
Temperature sensor measurement range
Temperature measurement resolution
Accuracy over calibration range
Temperature reading mode
LCD display
Top Coupling(Connection)
Battery
Intrinsically safe type
+/- 2mm
Visible and Audible
15M / 30M / 40M
Metric
1mm
+/-3.2mm
23mm
10mm
-20 to 70
-20 to 110
0.1
+/-0.2 (0 to 70 )
(Celsius)
2 Line 16 character
PF 2-1/4 TAP
9Volt (Model : MN1604)
Ex ia B T4
SAMPLERUTL
MODEL SPECIFICATIONAccuracy of Sensor Probe
Tape Graduation
Tape Resolution
Tape Length
Measurement Temperature Range
Ex Grade
2 mm
Metric
1mm
10M, 15M, 20M, 30M, 35M
-10 to 90
Ex ia C T4
Metric
1mm
10M, 15M, 20M, 30M
O.D 8mm I.D 6mm
15M
1
UTL-200
(OIL-WATER INTERFACE
DETECTOR)
Tape Graduation
Tape Resolution
Tape Length
2UTL-SPL-L
(LIQUID SAMPLER)
Hose Size
Hose Length3
UTL-SPL-G
(GAS SAMPLER)
2"(50A)
1"(25A)4 DECK VALVE
NO
-
7/29/2019 Marsen Catalog v6.0
24/26
47
www.m
arsen.c
o.k
r
46
www.m
arsen.c
o.k
r
World reading company inside measuring and control
www.marsen.co.kr
Portable Gas Detector & Sensor
Portable Gas Detector & Sensor
Suction type
Fixed Gas Sensors
Service
Salinity Meter (SAL-2000)
General Information
This salinity ppm alarm indicator developed for confirm to salinity density at fresh water generator or boiler feed water, etc.
This device is very easy operate because made by digital programming technology. Also this device is simple a componentand has a low maintenance. All components are made for endure marine environmental condition. For insurance to user's
trust, all product should be publish to certificate.
Features
High accuracy
Easy using method
Easy installation
Several accessory
Digital and Analog output available
Pump stop / start function available
Low price
Easy spread function with another system
rapidly delivery time
Consists Of System
1. Monitor
LCD display key pad
buzzer lamp
2. Sensor cell
3. Solenoid valve
4. Serial interface (option)
Application
Boiler Cascadetonk
Fresh Water Generator
-
7/29/2019 Marsen Catalog v6.0
25/26
49
www.m
arsen.c
o.k
r
48
www.m
arsen.c
o.k
r
World reading company inside measuring and control
www.marsen.co.kr
MGO-HFO Changeover System
General Information
This product is Low Sulphur Fuel Oil switching equipment that prevent marine air pollution caused by ships and meet air
pollution regulations, international maritime ship costs take up most of the fuel to ensure the reduction.Currently most of the ship to sail the oceans is used the primary fuel as the HFO (Heavy Fuel Oil), but it is being regulated to
used the low sulfur oil fuel MGO (Marine Gas Oil) in certain areas due to sulfur dioxide (SOx) emissions regulations, these
regulations will be strengthened in addition.
Features
1cSt ~ 10cSt measurable Viscosity Sensor and
Measurement Algorithm
Fuel oil pollution prevention, and automated
monitoring structures obtained Low Sulphur Oil
cooling system
1 minute 2 temperature variations controlled Oil
Changeover Unit to prevent thermal shock
Integrated Control Panel and the sequence of H.M.I
Type
LSFO Auto Changeover Control System Model
IMO/EU/USA/CANADA Rule SOx Discharge Restricted Area.
Specification
Contents
Rated Current
Rated Voltage
Safety Parameter
Wmax
Absorption Force
Duty Rating
Working Pressure
Ex Grade
SPECIFICATION
0.12A
DC 12V
Ui=13V Ii=2A Li=0mh Ci=0nF
4~5Watt
MIN 0.5N, MAX 1.5N
Continuous(100%)
160 bar, Max. 250bar(busting)
-20~+50
Ex Solenoid Valve (Model: HAS12)
Specification
Contents
Supply Voltage
Input Signal
Output Voltage
Storage
Temperature
Ex. Certification
Intrinsic
Associated
Devices parameter
SPECIFICATION
AC220V
DC24V
DC12V
-20 Ta +60
[Ex ia] C
Ui(4,6)=AC230V, Ui(1,2,3)=DC24V
Po = 1W
Uo = DC14V
Io = 290mA
Lo = 0.35mH
Co = 450nF
Ex Power Supply (Model: HAP12)
Specification
Contents
Location of Unit
Housing Material
Connection
Print Circuit Board
Supply Voltage
Input Signal
Output Voltage
Storage Temperature
SPECIFICATION
Safety Area
Polycarbonate (Light Gray)
Blade Pin Terminals
FR-4
DC24V
DC 4-20mA
Contact Point
-20 Ta +60
Current Signal Converter (Model: DAC420)
General Information
Ex Certification
Kr Certification for Explosion Proof Equipment
Patent application
-
7/29/2019 Marsen Catalog v6.0
26/26
50
www.m
arsen.c
o.k
r
World reading company inside measuring and control
General InformationDPT-420 is use for the purposed of measurement for flow rate of liquid, gas, steam flow rate. It is output of the analog signal
of DC 4-20ma measured Pressure corresponding.
VALUE
Supply PowerOutput Signal
Accuracy
Stability
Temperature
Ex Grade
Max Static Pressure
Pressure Range
SPECIFICATION
10~48VDC4-20mA, HART
0.050%
0.25%
-30 ~ +85
Ex ia C T5
40 Bar
0~0.2, 0~0.4, 0~1, 0~4, 0~10 BarD
General Information
Flow rate of fluid transport in marine is required the product of accuracy and reliability for a typical measurement
requirements. Pipe to measure the flow rate in the APT-200 by inserting a pressure differential voltage and the static
pressure generated by the average and the average differential pressure generated by the instrument to recognize the
device so that the signal is output.VALUE
Measuring fluid
Material
Size
Temperature
Working Pressure
Accuracy
repeatability
SPECIFICATION
Liquid, Gas, Steam Etc.
STS316, 304
Option : STS 316L
100A ~ 800A
300
Option : -196
20 Bar
1.0% FS
0.1% FS
VALUE
Main Power SupplyCommunication Mode
Valve Position Resolution
Delay Time Adjustment
Dead Band Adjustment
Duty Cycle (On-Off Duty)
Type of Protection
Degree of protection of
enclosure
Ambient Temperature
Fluid temperature
SPECIFICATION
V1 : AC220V 60Hz, V2 : DC24VRS232, RS422
MIN. 1/100
1~10 SEC. (1 STEP 1SEC 0~10 STEP)
0~20% (1 STEP 1% 0~20STEP)
S2, Max 30 Minutes
S4 50%
Ex d C T4
IP56
-20 ~ +60
-10 ~ +60
Differential Pressure Transmitter (Model:DPT-420)
Averaging Pitot Tube (Model:APT-200)
Electro-Hydraulic Power Pack (Model:EHPP-200)
51
www.m
arsen.c
o.k
r
www.marsen.co.kr
Pressure Pump
FeaturesThe dry block principle excludes the use of oil or other liquids.
A dry block with various diameters ensure thermal contact to sensor being tested.
Simply place the sensor to be calibrated in the calibrator. Set the temperature.
When stabilisation occurs, read the true temperature from the calibrator and recalibrate the sensor or system accordingly.
VALUE
Temperature range
Resolution (display)
Accuracy
Stability
Heating time to max
Cooling time to min
Thermostat test
Well depth
Well diameter
Power supply
Power consumpsion
Operating temperature
Dimension
Weight
SPECIFICATION
30 to 650
0.1
1.5
0.5
40 min
65 min
Yes
155 mm
26 mm
230 VAC, 50Hz
1600 Watt
110VAC, 60Hz
0 to 40
115 280 220
Abt. 5.5 kgs
VALUE
Pressure media
Pressure range
Reference
Test device
Housing
Weight
Including accessories
SPECIFICATION
Air
-1(-950mbar)... 40bar
G 3/8 A female, with quickconnection
G 1/4 A female, with hose(1.0m) & cup nut
220 105 63 mm
app. 500g
seals, service & case
Process
connection
Digital Reference Test Gauge
VALUE
Pressure connection
Display
Housing
Power supply
Accuracy
Measuring range
SPECIFICATION
G1/4" male tread
Multifunction LCD, 30x30mm
D=70, L=100, H=30mmweight app. 130g
protectin class IP68
3 V-battery
+/-0.5% FS +/-1 digit
-1......(30)40 bar / 0.01
Temperature Calibrator
Pressure Calibrator
top related