nanoporous peek hollow fiber-based gas/liquid membrane

Post on 13-May-2022

4 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

TW4-1

Nanoporous PEEK® Hollow

Fiber-based Gas/Liquid

Membrane Contactors for

Sour Gas Treating

> Vann Bush

Managing Director, Energy Conversion,

Gas Technology Institute

International Gas Union Research Conference

18 September 2014

IGRC 2014 2 IGRC 2014 2

Introduction

> GTI and PoroGen Inc. have teamed to develop a hollow fiber

membrane contactor (HFMC) technology as absorber and

regenerator stages for CO2 removal from natural gas to achieve

pipeline and LNG specifications

> We have carried out lab-scale tests of high-pressure absorption

and lower-pressure regeneration

> Advantages for the technology are:

• lower weight,

• smaller size systems,

• insensitivity to motion for offshore operations,

• no flooding,

• high turndown ratio, and

• modularity and shop fabrication for any capacity.

IGRC 2014 3 IGRC 2014 3

Technology Features

IGRC 2014 4 IGRC 2014 4

Hollow Fiber Function

Bore side

Shell side

Nanoporous PEEK ® fiber wall

IGRC 2014 5 IGRC 2014 5

Mass Transfer Performance

Gas‐liquid Contactor

Specific

Surface Area,

(m2/m3)

Volumetric Mass Transfer

Coefficient, (sec)-1

Packed Column (Countercurrent) 10 – 350 0.0004 – 0.07

Bubble Column (Agitated) 100 – 2,000 0.003 – 0.04

Spray Column 10 – 400 0.0007 – 0.075

Membrane Contactor 100 – 7,000 0.3 – 4.0

Comparison to other technologies

IGRC 2014 6

ABSORPTION SECTION

Laboratory Rig Flow Schematic

IGRC 2014 7 IGRC 2014 7

DESORPTION SECTION

Laboratory Rig Flow Schematic

IGRC 2014 8 IGRC 2014 8

Absorber Performance

IGRC 2014 9

Achieving Pipeline Specs

IGRC 2014 10 IGRC 2014 10

ABSORBER PERFORMANCE

Pipeline CO2 Specifications (~2 vol%)

> Liquid flow rate affects exit CO2 concentration: higher liquid rate = lower CO2

concentration

> Pipeline specifications achieved in tests with single membrane module

> Module parameters:

• Nominal 2 in. diameter module, 2,000 GPU, ~7,000 cm2 outside fiber area,

~1,200 fibers

• KG = 825 – 1150 mol/(m3·hr·Kpa), or 0.5 - 0.7 s-1

> Test conditions:

• 40 wt% (incl. 8 wt% piperazine) aMDEA at

• 950 psia, 24 °C

• non-integrated (no regenerator, once-through solvent)

• 1.6 ℓ/min solvent rate, 800 SCFH feed gas rate

IGRC 2014 11

Achieving LNG Specs

0

10

20

30

40

50

60

70

80

90

100

0

0,2

0,4

0,6

0,8

1

1,2

0 50 100 150 200 250

Ou

tle

t C

O2

Co

nc

, (p

pm

v)

Inle

t a

nd

Mid

po

int

CO

2 C

on

c, (m

ol%

)

Time (min)

Inlet CO2 (mol%) Midpoint CO2 (mol%) Outlet CO2 ppmv

IGRC 2014 12 IGRC 2014 12

ABSORBER PERFORMANCE

LNG Specs

> Feed gas at 1% CO2, very lean aMDEA solvent used

• First-stage membrane would be used to reduce feed to

1-2 vol% CO2, as shown separately

> Less than 60 ppmv CO2 specification on outlet reached

• We have demonstrated in other tests that lowering gas

flow slightly will achieve <50 ppmv CO2

> Excursion at ~220 min. deliberate – returned to previous

level when conditions were returned to original value

IGRC 2014 13 IGRC 2014 13

Integrated Test (~8 vol% CO2 to ~2 vol% CO2)

0

1

2

3

4

5

6

7

8

9

10

0 200 400 600 800 1000 1200 1400

CO

2 C

on

c.,

(m

ol%

)

Time, (min)

Absorb CO2 in (%) Absorb CO2 out (%)

IGRC 2014 14 IGRC 2014 14

ABSORBER PERFORMANCE

Integrated Test

> Membrane contactor in both absorber and regenerator stages

> Regenerator used directly to produce the lean solvent to the

absorber

• Lean solvent ~0.1 wt% CO2 or 0.0064 mol CO2/mol amine

• 23 solvent turnovers

> After startup adjustments, results stable over ~24 hr. test

> Outlet tracks inlet concentrations

> Slightly lower gas flow in test will likely produce <2 vol% CO2 in

outlet

• When CO2 in inlet was below 7% outlet approached 2%

IGRC 2014 15 IGRC 2014 15

ABSORBER PERFORMANCE

Effect of H2S

> Test was performed for conditions meeting LNG specs

• Feed Gas at 1 vol% CO2 and 950 psig, 71 °F

> 26 ppmv CO2 at 297 SCFH and 45 ppmv CO2 at 520 SCFH,

aMDEA flow at 0.35 ℓ/min

> Spiked H2S at different levels:

• With 250 ppmv spike, H2S was below detection limit of 0.1 ppmv

in exit gas

• With 500 ppmv spike, H2S was ~4 ppmv in exit gas

• CO2 was unchanged

IGRC 2014 16 IGRC 2014 16

Next Steps

> Continued laboratory and field testing

• Improve model to better understand

process at a fundamental level

• Get more operating time, data

• Optimize membrane configurations

> Obtain commercialization partner

• Provide engineering support, sales support

> Scale-up efforts

• Larger module fabrication

• Skid package design with pre-treatment

IGRC 2014 17 IGRC 2014 17

Next Steps (continued)

> Pilot Plant Test Objectives

• Test nominal 8 in. diameter, 1,000 ft2 modules –

10X scale up

• Determine pretreatment requirements

• Develop startup and shutdown protocols and best

practices for operating procedures

• Confirm membrane durability, performance life

through continuous, longer-term testing

IGRC 2014 18 IGRC 2014 18

Conclusions

> Promising R&D results

• High mass transfer rates confirmed for HFMC

o Up to an order of magnitude greater than packed columns

• Absorption and regeneration schemes tested successfully

> Path going forward identified

• JIP supported by 6 major oil and gas companies

o Next phase solicitation being evaluated

• Progressing discussions with engineering partners for commercialization

• DOE slipstream testing at National Carbon Capture Center (NCCC)

IGRC 2014 19 IGRC 2014 19

Acknowledgements

> GTI and PoroGen gratefully acknowledge the financial

support provided by Joint Industry Project sponsors for

the natural gas treating part of this work.

IGRC 2014 20 IGRC 2014 20

Connect With Us

Gas Technology Institute

1700 S Mount Prospect Rd, Des Plaines, IL 60018, USA

www.gastechnology.org

Contact:

Vann Bush

Managing Director,

Energy Conversion

847-768-0973

vann.bush@gastechnology.org

Authors:

Dr. S. James Zhou,

Howard Meyer, Dennis Leppin,

and Dr. Shiguang Li, GTI;

Dr. Ben Bikson and Dr. Yong

Ding, PoroGen Inc.

@gastechnology

top related