photo 1. tem pictures showing effects of microwave

Post on 21-Apr-2022

1 Views

Category:

Documents

0 Downloads

Preview:

Click to see full reader

TRANSCRIPT

Photo 1. TEM pictures showing effects of microwave treatment of eternit.

The results of X-ray examination (XRD) are illustrated in Photo 2.

Photo 2. XRD and TGA/DSC diagrams.

Photo 3. Ceramic half-rings by ZAMAC

Photo 4. MOS reactor filled with microwave-absorbing ceramics (view from the top).

Photo 5. Distribution of temperature in the chamber of the MOS reactor.

Metallic cover of the reactor

Microwave aplicator

Microwave – absorbing ceramic elements

Ceramic insulation

ATON 200 + MOS

ATON HR + MOS

Fig. 1 ATON 200 reactor with MOS reactor and ATON HR reactor with MOS reactor.

HR

MOS

ATON 200 cavity

Microwave generators

Crusher of product

ACM feeder

MOS reactor Exchaust gases

Photo 6. Power supplies located in the cabinet.

Figure 2. Chamber of a single heating segment with radiators

chamber

Ceramic insulation

Microwave generator

Metallic chamber

Microwave aplicator

chamber

Fig.3 Block diagram of control system

750-841 controller

750-603

750-603

750-604

750-604

750-431

750-431

750-431

750-431

750-431

750-431

750-455

750-555

750-530

750-530

750-530

750-530

750-530

750-530

750-530

750-530

750-530

750-530

Computer with Codesys software

Power supply1 Power supply 2

Power supply 3

Power supply n

Temperature 1 measurement (termocouple/pyrometer)

Temperature 2 measurement (termocouple/pyrometer)

Temperature 3 measurement (termocouple/pyrometer)

Temperature 4 measurement (termocouple/pyrometer)

Water pump

Fan power supplies

Heat exchanger

Loading maechanism

Unloading mechanism

… Power supply n-1

Photo 7. Display on the front panel of the control cabinet

Photo 8. Screen display with process parameters

USB

Fig. 7. Simplified diagram of a remote monitoring and control in AMIANTE system.

Photo 9. ATON 20 reactor with MOS reactor

Photo 10. ATON HR 300

Photo 11. ATON HR-lab

Photo 12. ATON HR 300 reactor with MOS system.

0

0,5

1

1,5

2

2,5

12:5

7:36

13:1

2:00

13:2

6:24

13:4

0:48

13:5

5:12

14:0

9:36

14:2

4:00

14:3

8:24

CO2/%CO2 [%]

Diagram 1. Selected diagrams of CO2, CO and VOC concentrations in off gases.

0

1

2

3

4

5

6

7

8

9

10

12:5

7:36

13:1

2:00

13:2

6:24

13:4

0:48

13:5

5:12

14:0

9:36

14:2

4:00

14:3

8:24

14:5

2:48

Wartość LZO/ppm

0

2

4

6

8

10

12

14

16

18

20

13:1

2:00

13:1

9:12

13:2

6:24

13:3

3:36

13:4

0:48

13:4

8:00

13:5

5:12

14:0

2:24

14:0

9:36

14:1

6:48

14:2

4:00

CO/ppmCO [ppm]

VOC [ppm]

Photo 13. HR reactor with MOS reactor under tests in Latvia.

(website link: http://www.novonews.lv/index.php?mode=photos&id=1063)

top related