andi gap dive planner software by kees hofwegen presentation by joseph a. radomski itd 10

20
ANDI GAP ANDI GAP Dive Planner Dive Planner Software By Software By Kees Hofwegen Kees Hofwegen Presentation By Presentation By Joseph A. Radomski Joseph A. Radomski ITD 10 ITD 10

Upload: laura-walton

Post on 18-Dec-2015

219 views

Category:

Documents


4 download

TRANSCRIPT

ANDI GAP ANDI GAP Dive PlannerDive Planner

Software BySoftware By

Kees HofwegenKees Hofwegen

Presentation ByPresentation By

Joseph A. RadomskiJoseph A. RadomskiITD 10ITD 10

Decompression ModelsDecompression Models

Bühlmann Bühlmann Deco curve controlled by Gradient FactorsDeco curve controlled by Gradient Factors

DCAP MF11F6DCAP MF11F6 Deco curve controlled by Gradient FactorsDeco curve controlled by Gradient Factors GF-Low of 99% and GF-High of 100% GF-Low of 99% and GF-High of 100%

approximate published tablesapproximate published tables RGBM (Reduced Gradient Bubble Model)RGBM (Reduced Gradient Bubble Model)

5 pre-programmed levels of conservatism5 pre-programmed levels of conservatism

BühlmannBühlmann

DCAP MF11F6DCAP MF11F6

RGBMRGBM

Descent/Ascent RatesDescent/Ascent Rates

Individual settings for ascent and Individual settings for ascent and descentdescent

Multiple rates based on depth Multiple rates based on depth

Decompression SettingsDecompression Settings

User defined User defined decompression gasesdecompression gases variable minimum stop variable minimum stop

times times at gas switch depthsat gas switch depths

decompression step sizedecompression step size last decompression stoplast decompression stop maximum allowable POmaximum allowable PO22

RMV entry for Open CircuitRMV entry for Open Circuitgas requirement gas requirement calculationscalculations

Gas SettingsGas Settings

Maximum POMaximum PO22 setting setting Automatic gas creationAutomatic gas creation Warnings/Alerts for exceeded limitsWarnings/Alerts for exceeded limits

Narcotic SettingsNarcotic Settings Automatic gas creationAutomatic gas creation Warnings/Alerts for exceeded limitsWarnings/Alerts for exceeded limits

By ENDBy END By PN2By PN2 OO22 narcotic (Yes/No) narcotic (Yes/No)

RMV entry for Open Circuit gas requirement RMV entry for Open Circuit gas requirement calculationscalculations

Available Gas MixesAvailable Gas Mixes

User Defined “Standard” gasesUser Defined “Standard” gases Sorted by Oxygen ContentSorted by Oxygen Content

(BUG in above screenshot has N(BUG in above screenshot has N22/He labels swapped, will be fixed in next /He labels swapped, will be fixed in next release)release)

Rebreather SettingsRebreather Settings

User Defined Default Set-PointUser Defined Default Set-Point Variable Set-Points for Decompression based on DepthVariable Set-Points for Decompression based on Depth

Added conservatism on hard to maintain set-points (above 1.3 bar at 6m, and 1.0 bar Added conservatism on hard to maintain set-points (above 1.3 bar at 6m, and 1.0 bar at 3m)at 3m)

Raising PORaising PO22 during decompression stops during decompression stops

Open Circuit Decompression for Bailout CalculationsOpen Circuit Decompression for Bailout Calculations

UnitsUnits

Dive planning in Metric or Imperial Dive planning in Metric or Imperial UnitsUnits

RGBM SettingsRGBM Settings

5 levels of Conservatism5 levels of Conservatism Extreme and Aggressive Settings Match Published Extreme and Aggressive Settings Match Published

TablesTables Nominal Setting is the Recommended starting point Nominal Setting is the Recommended starting point

for warm low workload dives.for warm low workload dives.

Neo-Haldane Settings Neo-Haldane Settings ( Bühlmann )( Bühlmann )

Gradient Factor - LOW determines Initial Stop DepthGradient Factor - LOW determines Initial Stop Depth Lower value causes deeper initial stopLower value causes deeper initial stop

Gradient Factor - HIGH determines overall Gradient Factor - HIGH determines overall conservatismconservatism Higher value reduces overall conservatismHigher value reduces overall conservatism

Selectable ZH-L16B or ZH-L16C M-ValuesSelectable ZH-L16B or ZH-L16C M-Values

Neo-Haldane ( DCAP )Neo-Haldane ( DCAP )

Dissolved Gas model based on DCAP MF11F6 M-valuesDissolved Gas model based on DCAP MF11F6 M-values Conservatism adjusted by Gradient FactorsConservatism adjusted by Gradient Factors GF-Low 99%, GF-High 100% approximates published GF-Low 99%, GF-High 100% approximates published

tablestables

Altitude SettingAltitude Setting

Used for Dive planning at altitudeUsed for Dive planning at altitude Ability to plan dives regardless of elapsed Ability to plan dives regardless of elapsed

time at altitude (No adaptation time time at altitude (No adaptation time necessary)necessary)

Way-Point Dialog BoxWay-Point Dialog Box

Entry of Segment depth and timeEntry of Segment depth and time(includes display of Total Elapsed time)(includes display of Total Elapsed time)

Select pre-defined Gases or Automatic gas Select pre-defined Gases or Automatic gas creation based on POcreation based on PO22 and Narcotic and Narcotic SettingsSettings

Dive ReportsDive Reports

3 Standard Report 3 Standard Report FormatsFormats Normal (Example Above)Normal (Example Above) LongLong Bail-OutBail-Out

Table Expert (Creator)Table Expert (Creator)

Tables Based on Tables Based on Template SettingsTemplate Settings Initial GasInitial Gas User defined Depth Ranges and TimesUser defined Depth Ranges and Times

Choice of 3 Output FormatsChoice of 3 Output Formats HTML, CSV, or Printed OutputHTML, CSV, or Printed Output

User RegistrationUser Registration

Each install generates an Unique IDEach install generates an Unique IDto register product (up to 2 registration keys) email user name, product to register product (up to 2 registration keys) email user name, product version, retail facility, and Unique ID (specify Desktop/Laptop for each) version, retail facility, and Unique ID (specify Desktop/Laptop for each)

to to [email protected]@andihq.com Key requests for 2nd computer must be submitted with original registration.Key requests for 2nd computer must be submitted with original registration. 14 Day evaluation Period – Freely Distribute14 Day evaluation Period – Freely Distribute Registration Serial determines active featuresRegistration Serial determines active features

For product support, Bug reports For product support, Bug reports and feature requests…..and feature requests…..

Send an Email to:Send an Email to:

[email protected]@andihq.com