When the Wanaka Ale House wanted to create a different and striking finish to their construction in Wanaka they looked to EuroPanel.®
Its striking look and colour created a signature presence in its lakeside position. EuroPanel® is available in both cooper and zinc and will provide a stunning finish to any property
EuroPanel® creates a finish that will make your project stand out from the rest
EuroPanel® in Copper
Wanaka Ale House, Wanaka
Euro
Pan
el®
Zealand Building Code and material warranty, especially in areas not naturally rain washed.
Profile Drawing
SpecificationsBMT Material Nominal Weight/lineal metre (kg/m)
0.70mm Copper 6.78
0.70mm Zinc 3.02
EuroPanel® a wall cladding only product, is a lightweight solution, which produces a high-level aesthetic finish. Used on a number of installations, including retail and residential.
Installation
EuroPanel® wall cladding must always be installed over a plywood (12mm minimum) substrate with a moisture content of less than 18% and made wind tight, with purlin supports underneath at 600mm centres in low to high wind zones and 400mm centres for very high and extra high wind zones. Avoid contact between Zinc and Bitumous papers.
Building Code Compliance
The product will, if employed in accordance with the supplier’s installation and maintenance requirements, assist with meeting the following provisions of the building code for a period of 15 years:
• Clause B2 Durability: Performance B2.3.1
• Clause E2 External moisture: Performance E2.3.1, E2.3.2
• Clause F2 Hazardous building materials: Performance F2.3.1
Additional Profile Information
Available in the following materials:
• Copper
• Zinc
Available as either Lock Seam or Hook Seam
Notes: Please consult with a Dimond® Representative before ordering for:
1. The correct coat to suit your cladding to match the environment.
2. Availability of any non standard colours, materials or thicknesses.
Maintenance must be carried out on your cladding to ensure the roof meets the required durability according to the New
EuroPanel®Residential and Commercial
NOTES1. Loads given are limited to a maximum of 4.15kPa. If design requirements exceed this limit,
Contact Dimond Roofing® for specific advice.
2. Design Criteria for Limit State Capacities a) Ultimate Limited State No pull through of fixings or fasteners withdrawal resulting in sheet detachment due to wind
up-lift (outward) loads
3. Wind Pressure Guide As a guide for non-specific design the following S.L.S. design loads in accordance with the MRM
Roofing Code of Practice can be used for buildings less than 10m high, otherwise AS/NZS 1170.2 should be used
Low wind zone = 0.68kPa, Medium wind zone = 0.93kPa, High wind zone = 1.32kPa, Very high wind zone = 1.72kPa and Extra high wind zone = 2.09kPa.
This product must be installed by a certified and approved RoofingSmiths installer. See roofingsmiths.co.nz
V0
1.0
3.0
119
To be used as a wall cladding only.
0800 DIMOND dimond.co.nz
December 2018
Lock Seam Hook Seam
W
H
W
H
Panel Tolerances
Cover (mm) H = 600 x W = 1125 Dimensions given are nominal
Panel length ‡ 5mm
Panel Height ‡ 5mm