ar cad isazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · ar cad is...

65
AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace Project Manager Voluntary Remediation Program Arizona Department of Environmental Quality 1110 West Washington Street Phoenix, Arizona 85007 Subject: Proposed Remedial Action Plan (P-RAP), Former Capitol Castings Facility Site, Tempe, Arizona, VRP Site Code: 504426-00 Dear Ms. Pace: On behalf of Victoria Technology, Inc., enclosed please find two copies (one bound and one unbound) of the P-RAP for the Former Capitol Castings Facility site located in Tempe, Arizona (VRP Site Code 504426-00). Once approved by the Arizona Department of Environmental Quality, the P-RAP will be sent to City of Tempe, ME Global, and Salt River Project. Please let us know if you have any questions. Thank you for your continued support on this project. Sincerely, ARCADIS U.S., Inc. Kathryn Brantingham, RG Associate Vice President Copies: Gerald Pepper, Victoria Technology, Inc. arcadis.com g:\env\env\proj\9001905 rio Onto 2107 tech_projects\_dce\2014-0S_prap\deliverables\prap rev 2\p-rap cover letter to adeq 20160229.docx ARCADIS U.S., Inc. 410 N. 44th Street Suite 1000 Phoenix Arizona 85008 Tel 602 438 0883 Fax 602 438 0102 www.arcadis.com ENVIRONMENT Date: February 29, 2016 Contact: Katy Brantingham Phone: 602. 797 .4523 Email : katy.brantingham @arcadis.com Our ref: AZ000905.3814 Page: 1/1

Upload: others

Post on 12-Aug-2020

0 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

AR CAD IS Infrastructure· Water· Environment· Buildings

Via Email and Federal Express

Joey Pace Project Manager Voluntary Remediation Program Arizona Department of Environmental Quality 1110 West Washington Street Phoenix, Arizona 85007

Subject:

Proposed Remedial Action Plan (P-RAP), Former Capitol Castings Facility Site, Tempe, Arizona, VRP Site Code: 504426-00

Dear Ms. Pace:

On behalf of Victoria Technology, Inc., enclosed please find two copies (one

bound and one unbound) of the P-RAP for the Former Capitol Castings Facility site located in Tempe, Arizona (VRP Site Code 504426-00). Once approved by

the Arizona Department of Environmental Quality, the P-RAP will be sent to City

of Tempe, ME Global, and Salt River Project.

Please let us know if you have any questions. Thank you for your continued

support on this project.

Sincerely,

ARCADIS U.S., Inc.

Kathryn Brantingham, RG Associate Vice President

Copies:

Gerald Pepper, Victoria Technology, Inc.

arcadis.com g:\env\env\proj\9001905 rio Onto 2107 tech_projects\_dce\2014-0S_prap\deliverables\prap rev 2\p-rap cover letter to adeq 20160229.docx

ARCADIS U.S., Inc.

410 N. 44th Street

Suite 1000

Phoenix

Arizona 85008

Tel 602 438 0883

Fax 602 438 0102

www.arcadis.com

ENVIRONMENT

Date:

February 29, 2016

Contact:

Katy Brantingham

Phone:

602. 797 .4523

Email :

katy.brantingham @arcadis.com

Our ref:

AZ000905.3814

Page:

1/1

Page 2: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Imagine the result

Victoria Technologies, Inc.

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

VRP Site Code: 504426-00

February 29, 2016

Page 3: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

fa ARCADIS

Christopher Shepherd, R.G. Senior Hydrogeologist

Kathryn Brantingham, R.G. Associate Vice President I CPM2

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

Prepared for:

Victoria Technologies, Inc.

Prepared by:

Arcadis U.S., Inc. 410 N. 44th Street

Suite 1000 Phoenix

Arizona 85008

Tel 602 438 0883 Fax 602 438 0102

Our Ref.:

AZ000905.3814

Date:

February 29, 2016

This document is intended only for the use

of the individual or entity for which it was

prepared and may contain information that

is privileged, confidential and exempt from

disclosure under applicable law. Any

dissemination, distribution or copying of

this document is strictly prohibited.

Page 4: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Table of Contents

1. INTRODUCTION 1

1.1 Report Organization 1

2. SITE BACKGROUND 2

2.1 Site Location and Facility History 2

2.2 Conceptual Site Model 2

2.2.1 Hydrogeology 2

2.2.2 Contaminants of Concern 4

2.2.3 Nature and Extent of 1,1-DCE Affected Groundwater 4

2.2.4 Groundwater Flow and 1,1-DCE Transport Modeling 6

3. REMEDIAL OBJECTIVES 6

4. REMEDY 7

4.1 Groundwater Monitoring 8

4.2 Determination of Whether to Implement the Contingency Actions and Remedy 9

4.2.1 Base Level Monitoring 10

4.2.2 Scenario Criteria 10

4.2.3 Action Levels 19

5. CONTINGENCY REMEDY 22

5.1 Groundwater Extraction Wells, Pumps and Piping 23

5.2 Treatment System 24

5.3 Operation, Maintenance and Monitoring 25

6. ESTIMATED REMEDY COSTS 26

7. REFERENCES 26

Tables

Table 1 Proposed Remedial Action Plan and Contingency Groundwater Monitoring Schedule

Table 2 Current and Foreseeable Designated Water Uses and Numeric Water Quality Standards

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx i

Page 5: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Table of Contents

Figures

Figure 1 Facility Location

Figure 2 Monitoring Well Locations

Figure 3 Distribution of 1,1-DCE in the S-Zone with Two-Year Summary of 1,1-DCE Concentrations

Figure 4 Distribution of 1,1-DCE in the D-Zone with Two-Year Summary of 1,1-DCE Concentrations

Figure 5 Distribution of 1,1-DCE in the D2-Zone with Two-Year Summary of 1,1-DCE Concentrations

Figure 6 Distribution of 1,1-DCE in the D3-Zone with Two-Year Summary of 1,1-DCE Concentrations

Figure 7 Hydrostratigraphic Cross-Section and Vertical Distribution 1,1-DCE

Figure 8 Groundwater Elevation Contours, S-Zone

Figure 9 Groundwater Elevation Contours, D-Zone

Figure 10 Groundwater Elevation Contours, D2-Zone

Figure 11 Groundwater Elevation Contours, D3-Zone

Figure 12 1,1-DCE Remedial Action Plan Groundwater Monitoring Network, S-Zone

Figure 13 1,1-DCE Remedial Action Plan Groundwater Monitoring Network, D-Zone

Figure 14 1,1-DCE Remedial Action Plan Groundwater Monitoring Network, D2-Zone

Figure 15 1,1-DCE Remedial Action Plan Groundwater Monitoring Network, D3-Zone

Figure 16 Decision Tree for SRP Well 21.5E-1.0S Contingency Actions and Remedy

Figure 17 Decision Tree for SRP Well 20.6E-1.1S 0S Contingency Actions and Remedy

Figure 18 Predicted 1,1-DCE Concentrations in SRP Well 21.5E-1.0S and the Average Sentinel Well Transect Concentration in Groundwater

Figure 19 Contingency Remedy Extraction Wells and Treatment System Process and Flow Diagram

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx ii

Page 6: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

~ ARCADIS

Appendices

A

B

iii

Mass Discharge Concentration Calculator

Estimated Costs

Table of Contents

Page 7: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

1. INTRODUCTION

Arcadis, on behalf of Victoria Technology, Inc. (VTI), has prepared this proposed Remedial Action Plan (P-RAP) for the former Capitol Castings facility located in Tempe, Arizona (the site, see Figure 1). The P-RAP addresses groundwater affected by 1,1-dichloroethene (1,1-DCE) from the former Capitol Castings facility. The site was entered into the Arizona Department of Environmental Quality (ADEQ) Voluntary Remediation Program (VRP) in 2002 (VRP Site Code: 504426-00).

This P-RAP was prepared in accordance with the ADEQ-approved land and water use study (ARCADIS 2006, ADEQ 2007), ADEQ-approved Remedial Investigation Report (including the ADEQ Remedial Objectives (RO) Report [ARCADIS 2010, ADEQ 2010, 2011a]), and ADEQ-approved Final Feasibility Study (FS) Report (ARCADIS 2014b, ADEQ 2014); and A.R.S. §§ 49-175 and 282.06 and A.A.C. R18-16-408.

The P-RAP describes: (1) the proposed plan for the ADEQ-approved remedy of continued groundwater monitoring; and (2) the proposed plan for the ADEQ-approved contingency remedy of controlled migration coupled with continued groundwater monitoring (ARCADIS 2014b, ADEQ 2014).

1.1 Report Organization

The remainder of the P-RAP is organized as follows:

• Section 2 – Site Background. This section briefly describes the site and its historical operations.

• Section 3 – Remedial Objectives. This section restates the ADEQ-approved remedial objectives.

• Section 4 – Remedy. This section describes the plan for the ADEQ-approved remedy of continued groundwater monitoring, including how a determination would be made whether to implement the contingency remedy of controlled migration coupled with continued groundwater monitoring.

• Section 5 – Contingency Remedy. This section describes the details of the ADEQ-approved contingency remedy of controlled migration coupled with continued groundwater monitoring.

• Section 6 – Estimated Costs. This section summarizes the estimated costs of the remedy and the contingency remedy.

• Section 7 – References. This section lists the sources of information cited in the P-RAP.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 1

Page 8: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

2. SITE BACKGROUND

This section presents a site description, facility history, and the current conceptual site model. A more detailed history of historical investigations and remediation to date are provided in the ADEQ-approved Final FS Report.

2.1 Site Location and Facility History

The site is located in the western half of Section 3, Township 1 South, Range 4 East of the Gila & Salt River Baseline and Meridian system and encompasses the monitoring well network (Figure 2), the 1,1-DCE affected groundwater (Figures 3 through 6), and the former Capitol Castings facility.

The facility is located at 5857 South Kyrene Road in Tempe, Arizona. It is bounded more or less by Western Canal and Kiwanis Park to the north and east, Kyrene Road to the west, and Guadalupe Road to the south. Beyond Kyrene Road are industrial and commercial properties (Figure 1).

The facility elevation is approximately 1,190 feet above mean sea level (amsl) and encompasses an area of approximately 27 acres, of which roughly one-half is developed. The developed portion of the facility is predominantly on the southern half of the property while the northern half is mostly undeveloped.

Operation of the facility began in 1953 as a secondary steel foundry that produced various steel castings used primarily by the mining industry for wear-resistant and structural applications. VTI owned and operated the facility from 1988 until 1994, when the facility was purchased by ME International. ME International’s successor in interest, ME Elecmetal (ME Global), currently owns and operates the facility as a metals casting facility.

2.2 Conceptual Site Model

2.2.1 Hydrogeology

The site is located in the western portion of the Eastern Salt River Valley (ESRV) sub-basin, which is part of Arizona’s Basin and Range physiographic province. The ESRV is a typical alluvial basin of the province and is surrounded by block-faulted mountain ranges, including the Phoenix, South, Superstition, and Santan Mountains and the Tempe pediments. Ground surface elevations and the depth to bedrock in the area

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 2

Page 9: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

generally dip away from the more proximal South Mountain and the Tempe pediments. The South Mountain range and the Tempe pediments are located approximately 2 miles west and 3.5 miles north of the site, respectively.

The ESRV basin fill is comprised of Quaternary to Tertiary alluvial deposits, Tertiary volcanic rocks and Tertiary to Precambrian crystalline rocks. The alluvial deposits are regionally divided into Upper, Middle, and Lower Units (Laney and Hahn 1986, ADWR 2006). The Upper, Middle, and Lower Alluvial Units are all present at the site.

The hydrogeology at the site consists of a multi-layered aquifer system and was divided into five primary water-bearing zones (the S-Zone and the four D-Zones). These zones are separated by fine grained sediments, which effectively act as aquitards (two A-Zones). The S-Zone is a perched aquifer system and the four D-Zones are considered to be the primary aquifers at the site. The S-Zone is present from the land surface to 112 feet below ground surface (bgs) and the depth to water in the S-Zone is approximately 65 feet bgs near monitoring well MW-10. The D- and A-Zones are further divided into more distinct zones: D-Zone (112 to 138 feet bgs); A-Zone (138 to 174 feet bgs); D2-Zone (174 to 207 feet bgs); A2-Zone (207 to 250 feet bgs); D3-Zone (250 to 335 feet bgs); and the D4-Zone (335 feet bgs to approximately 600 feet bgs)1. The D4-Zone is a sedimentary rock aquifer (breccia/conglomerate). Figure 7 shows the hydrostratigraphic zones in a north-south cross-section.

The groundwater elevations decrease significantly between the S- and D-Zone, the D- and D2-Zone, and between D2- and D3-Zone. The differences in groundwater elevations between D3- and D4-Zones are generally negligible. The aquitard or confining layers are significant hydraulic barriers, contributing to the large vertical gradients and limiting the vertical movement of contaminants of concern (COC) affected groundwater. The groundwater flow directions at the site vary by aquifer; however, they are generally to the south (varying from southeast to southwest), consistent with the regional groundwater flow near the site. The groundwater flow directions and magnitude are influenced by recharge from Kiwanis Lake and the Western Canal, regional pumping, and local groundwater pumping. The D2-, D3-, and the D4-Zones are the most influenced by local groundwater pumping and the S-Zone is primarily influenced by recharge. Figures 8 through 11 present the most current groundwater elevation contours for the S-, D-, D2-, and D3-Zones, respectively and are based on groundwater elevations measured in October 2014.

1 The ranges provided are based on average depths at the site.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 3

Page 10: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

Additional information concerning the site’s regional geology and hydrogeology are available in the ADEQ-approved RI Report and ADEQ-approved Final FS Report.

2.2.2 Contaminants of Concern

Groundwater at the site is affected by a chlorinated volatile organic compound (CVOC) release and a gasoline leaking underground storage tank (LUST) release. Based on the historical evaluations, 1,1-DCE, 1,2-dichloroethane (1,2-DCA) and benzene are the primary COCs. These three compounds are detected above their respective Arizona Aquifer Water Quality Standards (AWQS)2 and the maximum concentrations are typically two times greater than their respective AWQS, based on previous site investigations. The 1,2-DCA and benzene are related to the LUST release and the 1,1-DCE is related to the CVOC release. The 1,1-DCE is the only chemical in groundwater present beyond the facility boundary and addressed by the P-RAP. The LUST is being addressed by a separate plan. Historical information regarding the site, the two releases, and historical remedial actions is available in the ADEQ-approved Final FS Report and the LUST Groundwater Closure Assessment Report (ARCADIS 2014a and 2014b), respectively.

2.2.3 Nature and Extent of 1,1-DCE Affected Groundwater

Groundwater monitoring of the 1,1-DCE affected groundwater has been ongoing since 1993 and the monitoring well network has been expanded to cover the four primary groundwater aquifers (S-, D-, D2-, and D3-Zones). 1,1-DCE has not been detected in the deeper D3b-Zone (lower D3-Zone) or D4-Zone. The most recent (October 2014) distribution of 1,1-DCE among the aquifers is depicted in Figures 3 through 6. The vertical distribution of 1,1-DCE along the primary north-south axis is depicted in Figure 7.

The horizontal and vertical extent of the 1,1-DCE plume has been heavily influenced by regional pumping in the deeper aquifers. Pumping by Salt River Project (SRP) well 21.5E-1.0S has had the greatest influence on the migration of the plume (ARCADIS 2008, 2010) (see Figures 1 and 2). SRP well 21.5E-1.0S is screened in the D2-, A2-, and D3-Zones as well as the unaffected D4-Zone (ARCADIS 2008, 2010).

2 A.A.C. R18-11-405

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 4

Page 11: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

1,1-DCE concentrations in groundwater exceeded the AWQS in 6 of the 23 monitoring wells that are located within the facility boundaries in 2013 or 2014:

• Within the S-Zone (MW-14 and MW-22S);

• Across the S and D-Zones (MW-10, MW-11, and MW-22M); and

• Within the D-Zone (MW-22D).

1,1-DCE concentrations in groundwater exceeded the AWQS in 19 of the 44 monitoring wells that are located hydraulically downgradient of the facility in 2013 or 2014:

• S-Zone (MW-15);

• D-Zone (MW-15D, MW-25D, MW-26D, MW-30D, MW-31D, and MW-35D);

• D2-Zone (MW-15D2, MW-26D2, MW-28D2, MW-31D2, MW-34D2, MW-35D2, and MW-38D2); and

• D3-Zone (MW-26D3, MW-29D3, MW-34D3, MW-36D3, and MW-38D3).

The groundwater monitoring studies establish that 1,1-DCE concentrations have been declining with time (ARCADIS 2015). The peak 1,1-DCE concentrations have declined from:

• 16,000 micrograms per liter (µg/L) in 1994 to 22 µg/L in 2013 in the S-Zone (monitoring well MW-22S was not sampled in 2014 in accordance with the sampling schedule),

• 2,300 µg/L in 2002 to 870 µg/L in 2014 in the D-Zone,

• 530 µg/L in 2004 to 49 µg/L in 2014 in the D2-Zone, and

• 56 µg/L in 2004 to 26 µg/L in 2014 the D3-Zone.

These declines are attributed to natural attenuation of the 1,1-DCE, the source removal, and enhanced reductive dechlorination in-situ reactive zone treatment, described in the ADEQ-approved Final FS Report.

Select monitoring wells exhibit increasing trends along the plume boundaries of the 1,1-DCE affected groundwater (e.g. MW-36D3). This is the result of advective

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 5

Page 12: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

transport3 of the 1,1-DCE, predominantly due to the SRP well pumping, and some increases in 1,1-DCE concentrations in the downgradient wells were anticipated as indicated in the Final FS Report and the groundwater flow and 1,1-DCE transport modeling.

2.2.4 Groundwater Flow and 1,1-DCE Transport Modeling

The latest groundwater flow and solute transport model for the site (Phase III Model, appendix to the Final FS Report [ARCADIS 2014b]) predicts that any 1,1-DCE in the discharge from SRP well 21.5E-1.0S into Western Canal would never exceed 4 µg/L, based on the most likely (average) pumping rates for SRP well 21.5E-1.0S; and that this peak concentration would occur in 65 years (2080). SRP well 21.5E-1.0S is screened from the D2-Zone to the upper D4-Zone.

The Phase III Model predicts that any 1,1-DCE in the southernmost monitoring wells along Orion Street, hydraulically upgradient of SRP well 21.5E-1.0S, would never exceed 120 µg/L in the D2-Zone and 50 µg/L in the D3-Zone, based on the most likely (average) pumping rates for SRP well 21.5E-1.0S; and that these peaks would occur in 20 to 60 years (between 2035 and 2075).

The Phase III Model predicts that any 1,1-DCE in discharges from other water supply wells would never exceed laboratory reporting limits (0.5 to 1.0 µg/L), based on the most likely (average) pumping rates for the wells. This includes SRP well 20.6E-1.1S, which is located approximately 2,700 feet to the west-southwest of the MW-38 well cluster and discharges into High Line Canal (see Figure 1) and is screened from the A2-Zone to the D3-Zone; and ME Global well WS-1, which is used for industrial (non-potable) purposes, primarily as a fire suppression backup water supply. A more detailed explanation and summary of the modeling can be found in the ADEQ-approved Final FS Report.

3. REMEDIAL OBJECTIVES

Based on the ADEQ-approved RO Report (ADEQ 2009, 2010) the remedial objectives for the site are:

3 In some areas, the advective transport rate exceeds the natural attenuation rate.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 6

Page 13: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

• To protect against a loss or impairment of each industrial use of groundwater pumped from ME Global’s groundwater supply wells that is threatened to be lost or impaired as a result of the 1,1-DCE, while such threat exists; and

• To protect against a loss or impairment of each municipal, agricultural, industrial or other beneficial use of groundwater pumped from SRPs groundwater supply wells that is threatened to be lost or impaired as a result of the 1,1-DCE, while such threat exists.

These remedial objectives are the basis of the ADEQ-approved remedy and ADEQ-approved contingency remedy for the 1,1-DCE affected groundwater (ARCADIS 2014b, ADEQ 2014). The approved remedy and contingency remedy are, respectively, continued groundwater monitoring (see Section 4), and controlled migration coupled with continued groundwater monitoring (see Section 5).

4. REMEDY

As stated in the ADEQ-approved Final FS Report, the ADEQ-approved remedy of continued groundwater monitoring will:

(i) Provide further empirical verification of the Phase III Model’s predictions that: (a) 1,1-DCE concentrations in the discharge from SRP well 21.5E-1.0S into Western Canal would never exceed 4 μg/L and the highest concentration would occur around 2080; (b) 1,1-DCE concentrations in the discharge from SRP well 20.6E-1.1S into High Line Canal would never exceed 0.5 to1.0 μg/L; and (c) 1,1-DCE concentrations in the discharge of ME Global well WS-1 would never exceed 0.5 to1.0 μg/L; and

(ii) Enable a determination over the long term of: (a) whether there develops a threat of loss or impairment of any municipal, agricultural, industrial or other beneficial use of groundwater pumped from SRP well 21.5E-1.0S or SRP well 20.6E.1.1S as a result of the 1,1-DCE, which would be a trigger for the implementation of the contingency remedy of controlled migration coupled with continued groundwater monitoring; (b) whether there develops a threat of loss or impairment of any industrial use of groundwater pumped from ME Global well WS-1 as a result of the 1,1-DCE; and/or (c) whether a no action strategy would be consistent with the ADEQ-approved remedial objectives.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 7

Page 14: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

4.1 Groundwater Monitoring

Groundwater monitoring wells have been placed throughout the site in order to delineate the extent of the 1,1-DCE plume and evaluate 1,1-DCE concentration trends and advective transport over the years. A more focused group of wells screened within the S-, D-, D2-, D3-, and D4-Zones is selected for the purposes of the P-RAP:

• Conceptual site model (CSM) wells – will be used to monitor the core area of the 1,1-DCE affected groundwater;

• Key wells – will be used to monitor 1,1-DCE primary transport pathways;

• Sentinel wells – will be used to monitor the 1,1-DCE primary transport pathways upgradient of SRP wells 21.5E-1.0S and 20.6E.1.1S;

• Water supply (SRP) wells – SRP wells 21.5E-1.0S and 20.6E.1.1S will be used to monitor for any presence of 1,1-DCE in the discharges from those wells; and

• Water-level (WL) wells – will be used only to measure water levels to support the groundwater flow and 1,1-DCE transport assessments.

The designated wells are depicted in Figures 12 through 15. Groundwater monitoring activities will consist of the following:

• Measurement of water levels, including continuous water level monitoring using data logging pressure transducers in a select number of wells;

• Collection of groundwater samples from monitoring wells and laboratory analysis of the samples for 1,1-DCE using United States Environmental Protection Agency (USEPA) Method 8260B;

• Collection of water supply well discharge samples and laboratory analysis of the samples for 1,1-DCE using USEPA Method 524.2; and

• Monitoring of water supply well pumping.

The groundwater sampling and analysis for 1,1-DCE will be conducted on an semi-annual to every four years basis, depending on the purpose of the well, in accordance with the Base Level monitoring schedule in Table 1. Depth to groundwater measurements will be taken annually and the pressure transducer data will be downloaded annually and converted to groundwater elevations. The monthly and annual pumping totals for SRP wells 21.5E-1.0S and 20.6E.1.1S will also be recorded.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 8

Page 15: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

These monitoring frequencies may be increased, if required, as described in Section 4.2.

The groundwater samples will be collected from monitoring wells using a no-purge sampling method, e.g., HydraSleevesTM. The first year of no-purge sample analytical results will be collected at the Level 1 schedule (see Table 1) and compared to historical results and trends. If the results are similar to historical results and trends, the no-purge method will continue to be used for groundwater monitoring. Groundwater samples from the SRP wells will be collected from the SRP well discharge monitoring point. A revised Sampling and Analysis Plan (SAP) and Quality Assurance Project Plan (QAPP) will be prepared for the groundwater monitoring activities following approval of the P-RAP.

The groundwater monitoring data will be assessed and reported to the ADEQ annually by March 31st of the following year. The assessment will include verification of: (i) ME Global’s industrial use of the groundwater; (ii) the designated uses of the canal water into which SRP well 21.5E-1.0S discharges (Western Canal and Kiwanis Park Lake); and (iii) the designated uses of the canal water into which SRP well 20.6E-1.1S discharges (High Line Canal). The reporting frequency may be increased, if required, as described in Section 4.2.

4.2 Determination of Whether to Implement the Contingency Actions and Remedy

The groundwater monitoring data will be used to determine whether there develops a threat of loss or impairment of any municipal, agricultural, industrial or other beneficial use of groundwater pumped from SRP well 21.5E-1.0S or SRP well 20.6E.1.1S as a result of the 1,1-DCE, which would be a trigger for the implementation of the contingency remedy of controlled migration coupled with continued groundwater monitoring described in Section 5. The approach to such a determination would involve an escalation of remedial activities in a phased manner, depending on the groundwater monitoring data, and include elements such as increased groundwater monitoring, sampling and analysis; increased reporting; installation of additional monitoring wells; updates of the groundwater flow and solute transport model; and, if necessary, installation of contingency groundwater extraction wells and implementation of the contingency remedy. The approach is depicted in Figure 16 (in relation to SRP well 21.5E-1.0S) and Figure 17 (in relation to SRP well 20.6E-1.1S) and is described in sections 4.2.1 through 4.2.3 below; and provides sufficient time to determine whether there develops a threat of loss or impairment of any municipal, agricultural, industrial or other beneficial use of groundwater pumped from SRP well 21.5E-1.0S or SRP well

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 9

Page 16: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

20.6E.1.1S as a result of the 1,1-DCE. The approach is conservative (decision-making will be based on calculations and models that bias 1,1-DCE discharge concentrations on the high end) and provides a bi-directional framework, allowing for escalation or de-escalation as appropriate.

Since ME Global’s industrial use of the groundwater is not threatened (i.e., the maximum groundwater concentration is less than the most conservative, applicable numeric water quality standard [Table 2]), no contingency actions have been established for this well. If ME Global’s industrial use of the groundwater changes, VTI will evaluate and employ additional remedial strategies in order to safeguard or achieve the ADEQ-approved remedial objectives pertaining to ME Global’s industrial use of groundwater.

4.2.1 Base Level Monitoring

As stated in Section 4.1, the groundwater monitoring will be conducted in accordance initially with the Base Level monitoring schedule in Table 1, using the wells depicted in Figures 12 through 15, and the groundwater samples will be analyzed for 1,1-DCE. VTI will use the monitoring data to determine whether a Scenario 1 or subsequent criterion is met, which would trigger a corresponding Action Level, as described in Sections 4.2.2 and 4.2.3 and depicted in Figures 16 and 17. If a Scenario 1 or subsequent criterion is not met, then the monitoring schedule will remain at the Base Level.

4.2.2 Scenario Criteria

This Section 4.2.2 states the Scenario Criteria which, if met, trigger corresponding Action Level requirements in Section 4.2.3. The Scenario Criteria and Action Level requirements are depicted in Figures 16 and 17.

4.2.2.1. Concentrations of 1,1-DCE in the Transect Sentinel Wells Upgradient of SRP Well 21.5E-1.0S (Figure 16)

• Scenario 1 - If the actual zone-averaged concentration of 1,1-DCE in transect sentinel wells MW-34D2/D3, MW-36D2/D3 and MW-33D2/D3 is greater than 80 percent of the model-predicted peak zone-averaged concentration of 1,1-DCE in those wells, then Action Level 1 applies.

• Scenario 2 - If the actual zone-averaged concentration of 1,1-DCE in transect sentinel wells MW-34D2/D3, MW-36D2/D3 and MW-33D2/D3 is greater than 125

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 10

Page 17: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

percent of the model-predicted peak zone-averaged concentration of 1,1-DCE in those wells, then Action Level 2 applies.

• Scenario 3 - If the actual concentrations of 1,1-DCE in transect sentinel wells MW-34D2/D3, MW-36D/A2/D2/D3 and MW-33D2/D3 indicate the 1,1-DCE concentration in the SRP well 21.5E-1.0S discharge could be greater than 6.3 µg/L in the future using the mass flux principle, then Action Level 3 applies.

Notes:

1. Actual zone-averaged concentrations of 1,1-DCE in the transect sentinel wells will be calculated as follows: the concentrations of 1,1-DCE in samples collected from monitoring wells MW-34D2, MW-36D2 and MW-33D2 will be averaged; and the concentrations of 1,1-DCE in samples collected from monitoring wells MW-34D3, MW-36D3 and MW-33D3 will be averaged.

2. Model-predicted peak zone-averaged concentrations of 1,1-DCE in the transect sentinel wells will be calculated as follows: the peak D2-Zone model-predicted 1,1-DCE concentrations from monitoring wells MW-34D2, MW-36D2 and MW-33D2 will be averaged; and the peak D3-Zone model-predicted 1,1-DCE concentrations from monitoring wells MW-34D3, MW-36D3 and MW-33D3 will be averaged. The model-predicted zone-averaged concentrations of 1,1-DCE versus time in the transect sentinel wells are depicted in Figure 18. The model-predicted peak 1,1-DCE concentrations are 41 µg/L (occurring in 2063) for the D2-Zone and 18 µg/L (occurring in 2060) for the D3-Zone.

3. Based on the model predictions and flux–based behavior of the 1,1-DCE, the 80 and 125 percent thresholds and the 6.3 µg/L trigger will iteratively provide ample time to implement the more aggressive Action Level monitoring and, if necessary, based on the resulting additional monitoring data, the contingency remedy described in Section 5.

4. All model predictions employ the average pumping scenario for SRP wells. This pumping scenario is part of the Phase III Model Report which is an appendix to the ADEQ-approved Final FS Report (ARCADIS 2014b) and is the ADEQ-approved model for remedial action planning for the 1,1-DCE affected groundwater at the Site. The scenario criteria take into account also the advective transport rates from the high pumping scenario utilized in the ADEQ-approved Phase II Groundwater Flow and Solute Transport Model (ADEQ 2011b, ARCADIS 2008), an earlier iteration of the Phase III Model.

5. Appendix A describes the mass flux principle and calculation method for estimating the concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S based on

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 11

Page 18: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

the concentration of 1,1-DCE in the transect sentinel wells (See also ITRC 2010). The method utilizes conservative assumptions to provide a biased high estimate of what the SRP well discharge concentration could be at a future date.

4.2.2.2. Concentrations of 1,1-DCE in the Transect Sentinel Wells Upgradient of SRP Well 20.6E-1.1S (Figure 17)

• Scenario 1 – If the actual concentrations of 1,1-DCE in transect sentinel wells MW-24D2/D3, MW-38D2/D3 and MW-34D2/D3 indicate the 1,1-DCE concentration in the SRP well 20.6E-1.1S discharge could be greater than 3.2 µg/L in the future using the mass flux principle, then Action Level 1 applies.

• Scenario 2 – If the actual concentrations of 1,1-DCE in transect sentinel wells MW-24D2/D3, MW-38D2/D3 and MW-34D2/D3 indicate the 1,1-DCE concentration in the SRP well 20.6E-1.1S discharge could be greater than 5.6 µg/L in the future using the mass flux principle, then Action Level 2 applies.

• Scenario 3 – If the actual concentrations of 1,1-DCE in transect sentinel wells MW-24D2/D3, MW-38D2/D3 and MW-34D2/D3 (including any new SRP well 20.6E-1.1S sentinel wells, as applicable) indicate the 1,1-DCE concentration in the SRP well 20.6E-1.1S discharge could be greater than 6.3 µg/L in the future using the mass flux principle, then Action Level 3 applies.

Notes:

1. Appendix A describes the mass flux principle and calculation method for estimating the concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S based on the concentration of 1,1-DCE in the transect sentinel wells (See also ITRC 2010). The method utilizes conservative assumptions to provide a biased high estimate of what the SRP well discharge concentration could be at a future date. The calculations also conservatively assume all of the 1,1-DCE along the transect will be captured by SRP well 20.6E-1.1S which is unlikely.

2. Based on advective transport calculations and the flux-based behavior of the 1,1-DCE observed in the model simulations, the 3.2 µg/L, 5.6 µg/L and 6.3 µg/L triggers will iteratively provide ample time to implement the more aggressive Action Level monitoring and, if necessary, based on the resulting additional monitoring data, the contingency remedy described in Section 5.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 12

Page 19: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

4.2.2.3. Actual Concentration of 1,1-DCE in the Discharge from SRP Well 21.5E-1.0S (Figure 16)

• Scenario 1 – If the actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S is greater than 80 percent of the model-predicted peak concentration of 1,1-DCE in the discharge from that well, then Action Level 1 applies.

• Scenario 2 – If the actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S is greater than 100 percent of the model-predicted peak concentration of 1,1-DCE in the discharge from that well, then Action Level 2 applies.

• Scenario 3 – If the actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S is greater than 5.6 µg/L, then Action Level 3 applies.

• Scenario 4 – If the actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S is greater than 6.3 µg/L, then Action Level 4 applies.

Notes:

1. The actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S will be the average of: (a) the concentration of 1,1-DCE that is in an initial sample of the discharge; and (b) the concentration of 1,1-DCE that is in a confirmation sample of the discharge that is collected within 30 days of the initial sample.

2. The current model-predicted peak concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S is depicted in Figure 18.

3. Based on the model predictions, the 80 and 100 percent thresholds and the 5.6 µg/L and 6.3 µg/L triggers will iteratively provide ample time to implement the more aggressive Action Level monitoring and, if necessary, based on the resulting additional monitoring data, the contingency remedy described in Section 5.

4. All model predictions employ the average pumping scenario for SRP wells. This pumping scenario is part of the Phase III Model Report which is an appendix to the ADEQ-approved Final FS Report (ARCADIS 2014b) and is the ADEQ-approved model for remedial action planning for the 1,1-DCE affected groundwater at the Site. The scenario criteria take into account also the advective transport rates from the high pumping scenario utilized in the ADEQ-approved Phase II Groundwater Flow and Solute Transport Model (ADEQ 2011b, ARCADIS 2008), an earlier iteration of the Phase III Model.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 13

Page 20: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

4.2.2.4. Actual Concentration of 1,1-DCE in the Discharge from SRP Well 20.6E-1.1S (Figure 17)

• Scenario 1 – If the actual concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S is greater than 1.0 µg/L, then Action Level 1 applies.

• Scenario 2 – If the actual concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S is greater than 4.0 µg/L, then Action Level 2 applies.

• Scenario 3 – If the actual concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S is greater than 5.6 µg/L, then Action Level 3 applies.

• Scenario 4 – If the actual concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S is greater than 6.3 µg/L, then Action Level 4 applies.

Notes:

1. The actual concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S will be the average of: (a) the concentration of 1,1-DCE that is in an initial sample of the discharge; and (b) the concentration of 1,1-DCE that is in a confirmation sample of the discharge that is collected within 30 days of the initial sample.

2. The model predicts that the concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S will remain below 1.0 µg/L.

3. Based on advective transport calculations and the flux-based behavior of the 1,1-DCE observed in the model simulations, the 1.0 µg/L, 4.0µg/L, 5.6 µg/L and 6.3 µg/L triggers will iteratively provide ample time to implement the more aggressive Action Level monitoring and, if necessary, based on the resulting additional monitoring data, the contingency remedy described in Section 5.

4. All model predictions employ the average pumping scenario for SRP wells. This pumping scenario is part of the Phase III Model Report which is an appendix to the ADEQ-approved Final FS Report (ARCADIS 2014b) and is the ADEQ-approved model for remedial action planning for the 1,1-DCE affected groundwater at the Site. The scenario criteria take into account also the advective transport rates from the high pumping scenario utilized in the ADEQ-approved Phase II Groundwater Flow and Solute Transport Model (ADEQ 2011b, ARCADIS 2008), an earlier iteration of the Phase III Model.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 14

Page 21: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

4.2.2.5. Rate of Increase in the Actual Concentration of 1,1-DCE in the Discharge from SRP Well 21.5E-1.0S (Figure 16)

• Scenario 1 – If the rate of increase in the actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S is 75 percent greater than the model-predicted (average) rate of increase of the concentration of 1,1-DCE in the discharge, then Action Level 1 applies.

• Scenario 2 – If the rate of increase in the actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S is significant and indicates the concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S will, within the next four years, exceed 5.6 µg/L, then Action Level 2 applies.

• Scenario 3 – If the rate of increase in the actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S is significant and indicates the concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S will, within the next two years, exceed 5.6 µg/L, then Action Level 3 applies.

• Scenario 4 – If the rate of increase in the actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S is significant and indicates the concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S will, within the next two years, exceed 7 µg/L, then Action Level 4 applies.

Notes:

1. The rate of increase of the actual concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S will be determined using linear regression of four or more sets of sample analytical results and assessed for significance. The current model-predicted 1,1-DCE concentration rate of change in the discharge from SRP well 21.5E-1.0S is depicted in Figure 18.

2. Based on the model predictions, the 75 percent greater than threshold and the 5.6 µg/L and 7 µg/L triggers, and four-year and two-year timeframes will iteratively provide ample time to implement the more aggressive Action Level monitoring and, if necessary, based on the resulting additional monitoring data, the contingency remedy described in Section 5.

3. All model predictions employ the average pumping scenario for SRP wells. This pumping scenario is part of the Phase III Model Report which is an appendix to the ADEQ-approved Final FS Report (ARCADIS 2014b) and is the ADEQ-approved model for remedial action planning for the 1,1-DCE affected groundwater at the Site. The scenario criteria take into account also the advective transport rates from the high pumping scenario utilized in the ADEQ-approved Phase II Groundwater

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 15

Page 22: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

Flow and Solute Transport Model (ADEQ 2011b, ARCADIS 2008), an earlier iteration of the Phase III Model.

4. Under Scenario 4, 3 to 4 months would be needed to construct the groundwater capture and treatment system that is part of the contingency remedy described in Section 5.

5. The currently applicable designated uses of canal water in Western Canal and High Line Canal are AgI and AgL, for which there are no 1,1-DCE numeric water quality standards (see Table 2). Western Canal also supplies water to Kiwanis Park Lake. The currently applicable designated uses of water in Kiwanis Park Lake are FBC, PBC, A&Ww and AgI, for which the most stringent 1,1-DCE numeric water quality standard is 950 µg/L (see Table 2). There is presently no proposal in the Arizona Administrative Register to change the designated use of the canal water to DWS. Also, the AZPDES permit that governs discharges into SRP’s canals does not impose a numeric discharge limitation for 1,1-DCE because of ADEQ’s determination that discharges into Western Canal entail no reasonable potential for an exceedance of a corresponding receiving water quality standard under applicable rules (ADEQ 2005). However, a use of the canal water as a DWS is foreseeable (see Table 2; see also footnote 4 of the ADEQ-approved FS Report). The 5.6 µg/L trigger that is specified would be 80% of the 1,1-DCE numeric water quality standard of 7 µg/L that applies to canal waters the designated uses of which include DWS, assuming a mixing zone is not allowed.

6. If a mixing zone is allowed or the 7 µg/L standard is ever revised, then that would necessitate a corresponding amendment of the Remedial Action Plan to change the Scenario Criteria that are functions of that standard.

4.2.2.6. Rate of Increase in the Actual Concentration of 1,1-DCE in the Discharge from SRP Well 20.6E-1.1S (Figure 17)

• Scenario 2 – If the rate of increase in the actual concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S is significant and indicates the concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S will, within the next four years, exceed 5.6 µg/L, then Action Level 2 applies.

• Scenario 3 – If the rate of increase in the actual concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S is significant and indicates the concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S will, within the next two years, exceed 5.6 µg/L, then Action Level 3 applies.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 16

Page 23: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

• Scenario 4 – If the rate of increase in the actual concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S is significant and indicates the concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S will, within the next two years, exceed 7 µg/L, then Action Level 4 applies.

Notes:

1. The rate of increase of the actual concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S will be determined using linear regression of four or more sets of sample analytical results and assessed for significance.

2. Based on advective transport calculations and the flux-based behavior of the 1,1-DCE observed in the model simulations, the 5.6 µg/L and 7 µg/L triggers and four-year and two-year timeframes will iteratively provide ample time to implement the more aggressive Action Level monitoring and, if necessary, based on the resulting additional monitoring data, the contingency remedy described in Section 5.

3. All model predictions employ the average pumping scenario for SRP wells. This pumping scenario is part of the Phase III Model Report which is an appendix to the ADEQ-approved Final FS Report (ARCADIS 2014b) and is the ADEQ-approved model for remedial action planning for the 1,1-DCE affected groundwater at the Site. The scenario criteria take into account also the advective transport rates from the high pumping scenario utilized in the ADEQ-approved Phase II Groundwater Flow and Solute Transport Model (ADEQ 2011b, ARCADIS 2008), an earlier iteration of the Phase III Model.

4. Under Scenario 4, 3 to 4 months would be needed to construct the groundwater capture and treatment system that is part of the contingency remedy described in Section 5.

5. The currently applicable designated uses of canal water in High Line Canal are AgI and AgL, for which there are no 1,1-DCE numeric water quality standards (see Table 2). There is presently no proposal in the Arizona Administrative Register to change the designated use of the canal water to DWS. However, a use of the canal water as a DWS is foreseeable (see Table 2; see also footnote 4 of the ADEQ-approved FS Report). The 5.6 µg/L trigger that is specified would be 80% of the 1,1-DCE numeric water quality standard of 7 µg/L that applies to canal waters the designated uses of which include DWS, assuming a mixing zone is not allowed.

6. If a mixing zone is allowed or the 7 µg/L standard is ever revised, then that would necessitate a corresponding amendment of the Remedial Action Plan to change the Scenario Criteria that are functions of that standard.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 17

Page 24: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

4.2.2.7. Revision of Model-Predicted Peak Concentration of 1,1-DCE in the Discharge from SRP Well 21.5E-1.0S (Figure 16)

• Scenario 3 – If the groundwater flow and solute transport model, as updated pursuant to Action Level 2 requirements, indicates the concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S will, within the next four years, exceed 5.6 µg/L, then Action Level 3 applies.

• Scenario 4 – If the groundwater flow and solute transport model, as updated pursuant to Action Level 3 requirements, indicates the concentration of 1,1-DCE in the discharge from SRP well 21.5E-1.0S will, within the next four years, exceed 7 µg/L, then Action Level 4 applies.

Notes:

1. Based on the model predictions, the 5.6 µg/L and 7 µg/L triggers and four-year timeframe will iteratively provide ample time to implement the more aggressive Action Level monitoring and, if necessary, based on the resulting additional monitoring data, the contingency remedy described in Section 5.

2. All model predictions employ the average pumping scenario for SRP wells. This pumping scenario is part of the Phase III Model Report which is an appendix to the ADEQ-approved Final FS Report (ARCADIS 2014b) and is the ADEQ-approved model for remedial action planning for the 1,1-DCE affected groundwater at the Site. The scenario criteria take into account also the advective transport rates from the high pumping scenario utilized in the ADEQ-approved Phase II Groundwater Flow and Solute Transport Model (ADEQ 2011b, ARCADIS 2008), an earlier iteration of the Phase III Model.

3. If a mixing zone is allowed or the 7 µg/L standard is ever revised, then that would necessitate a corresponding amendment of the Remedial Action Plan to change the Scenario Criteria that are functions of that standard.

4.2.2.8. Revision of Model-Predicted Peak Concentration of 1,1-DCE in the Discharge from SRP Well 20.6E-1.1S (Figure 17)

• Scenario 3 – If the groundwater flow and solute transport model, as updated pursuant to Action Level 2 requirements, indicates the concentration of 1,1-DCE in the discharge from SRP well 20.6E-1.1S will, within the next four years, exceed 5.6 µg/L, then Action Level 3 applies.

• Scenario 4 – If the groundwater flow and solute transport model, as updated pursuant to Action Level 3 requirements, indicates the concentration of 1,1-DCE in

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 18

Page 25: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

the discharge from SRP well 20.6E-1.1S will, within the next four years, exceed 7 µg/L, then Action Level 4 applies.

Notes:

1. Based on advective transport calculations and the flux-based behavior of the 1,1-DCE observed in the model simulations, the 5.6 µg/L and 7 µg/L triggers and four-year timeframe will iteratively provide ample time to implement the more aggressive Action Level monitoring and, if necessary, based on the resulting additional monitoring data, the contingency remedy described in Section 5.

2. All model predictions employ the average pumping scenario for SRP wells. This pumping scenario is part of the Phase III Model Report which is an appendix to the ADEQ-approved Final FS Report (ARCADIS 2014b) and is the ADEQ-approved model for remedial action planning for the 1,1-DCE affected groundwater at the Site. The scenario criteria take into account also the advective transport rates from the high pumping scenario utilized in the ADEQ-approved Phase II Groundwater Flow and Solute Transport Model (ADEQ 2011b, ARCADIS 2008), an earlier iteration of the Phase III Model.

3. If a mixing zone is allowed or the 7 µg/L standard is ever revised, then that would necessitate a corresponding amendment of the Remedial Action Plan to change the Scenario Criteria that are functions of that standard.

4.2.3 Action Levels

This Section 4.2.3 states the Action Level requirements that are triggered by corresponding Scenario Criteria described in Section 4.2.2.

4.2.3.1. Action Level 1 Requirements

If a Scenario 1 criterion is met, then that would trigger Action Level 1 requirements as specified below (see also Figures 16 and 17):

• Increase monitoring data density through Level 1 Monitoring (see Table 1) in the vicinity of the SRP well(s) for which a Scenario 1 criterion is met (SRP well 21.5E-1.0S or/and 20.6E-1.1S) and in the vicinity of the key wells and sentinel wells upgradient of the SRP well(s) in order to enhance empirical determinations based on 1,1-DCE concentrations and trends in the wells; and

• Determine whether Action Level 2 applies using the Scenario Criteria described in Section 4.2.2.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 19

Page 26: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

4.2.3.2. Action Level 2 Requirements

If a Scenario 2 criterion is met, then that would trigger Action Level 2 requirements as specified below (see also Figures 16 and 17):

• Increase monitoring data density through Level 2 Monitoring (see Table 1) in the vicinity of the SRP well(s) for which a Scenario 2 criterion is met (21.5E-1.0S or/and 20.6E-1.1S) and in the vicinity of the key wells and sentinel wells upgradient of the SRP well(s) in order to enhance empirical determinations based on 1,1-DCE concentrations and trends;

• Verify or update model predictions accordingly and report findings to the ADEQ;

• Determine optimal locations for one or more sentinel/contingency groundwater extraction wells, as appropriate, upgradient of the SRP well(s) for which a Scenario 2 criterion is met (21.5E-1.0S or/and 20.6E-1.1S) and secure access agreements for those locations;

• If a Scenario 2 criterion is met with regard to, or upgradient from, SRP well 20.6E-1.1S, install one to two additional D2- and D3-Zone sentinel wells in order to provide improved definition of 1,1-DCE upgradient from SRP well 20.6E-1.1S; and

• Determine whether Action Level 3 applies using the Scenario Criteria described in Section 4.2.2.

4.2.3.3. Action Level 3 Requirements

If a Scenario 3 criterion is met, then that would trigger Action Level 3 requirements as specified below (see also Figures 16 and 17):

• Increase monitoring data density through Level 3 Monitoring (see Table 1) in the vicinity of the SRP well(s) for which a Scenario 3 criterion is met (21.5E-1.0S or/and 20.6E-1.1S) and in the vicinity of the key wells and sentinel wells upgradient of the SRP well(s) in order to enhance empirical determinations based on 1,1-DCE concentrations and trends;

• Verify or update model predictions accordingly (if necessary, recalibrate the groundwater flow and solute transport model) and report findings to the ADEQ;

• Install the one or more sentinel/contingency groundwater extraction wells pursuant to the previously secured access agreements (see Section 4.2.3.2);

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 20

Page 27: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

• Determine optimal locations for additional sentinel wells, if appropriate, in relation to the SRP well(s) for which a Scenario 3 criterion is met (21.5E-1.0S or/and 20.6E-1.1S), secure access agreements for those locations, and install such sentinel wells;

• Substantially complete the design of the groundwater treatment system which is described in Section 5, identify optimal location(s) for the treatment system and appurtenances, and secure access agreements for the location(s); and

• Determine whether Action Level 4 applies using the Scenario Criteria described in Section 4.2.2.

4.2.3.4. Action Level 4 Requirements

If a Scenario 4 criterion is met, then that would trigger Action Level 4 requirements as specified below (see also Figures 16 and 17):

• Increase monitoring data density through Level 4 Monitoring (see Table 1) in the vicinity of the SRP well(s) for which a Scenario 4 criterion is met (21.5E-1.0S or/and 20.6E-1.1S) and in the vicinity of the key wells and sentinel wells upgradient of the SRP well(s) in order to enhance empirical determinations based on 1,1-DCE concentrations and trends;

• Verify or update model predictions to support the design or optimization of the groundwater treatment system, as appropriate and report findings to the ADEQ;

• Complete the design of the groundwater treatment system which is described in Section 5;

• Prepare and submit for ADEQ review and approval a groundwater treatment system operation, maintenance and monitoring (OM&M) plan (Section 5.3);

• Construct and install the treatment system pursuant to the completed design and the previously secured access agreements (see Section 4.2.3.3);

• Activate and commence operation of the treatment system;

• Monitor the effectiveness of the treatment system, so as to verify the ability of the contingency remedy to avoid a loss or impairment of any municipal, agricultural, industrial or other beneficial use of groundwater pumped from the SRP well(s) for which a Scenario 4 criterion is met (21.5E-1.0S or/and 20.6E-1.1S) as a result of the 1,1-DCE; and

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 21

Page 28: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

• Determine if amendments to the FS Report and Remedial Action Plan are required to evaluate and employ a remedial strategy that is more aggressive than the contingency remedy in order to safeguard or achieve the ADEQ-approved remedial objectives or the contingency remedy may be suspended as part of a reversion to Action Level 3 or a lesser Action Level.

5. CONTINGENCY REMEDY

As described above, if a Scenario 4 criterion is met, then that would trigger the requirement to complete the design of, and construct, and operate, the groundwater treatment system while continuing the Level 4 groundwater monitoring. This would comprise the ADEQ-approved contingency remedy (ARCADIS 2014b, ADEQ 2014) of controlled migration using groundwater extraction and granular activated carbon (GAC) adsorption coupled with continued groundwater monitoring.

The goal of controlled migration and treatment would be to ensure that the concentration of any 1,1-DCE in the discharge from SRP well 21.5E-1.0S or SRP well 20.6E-1.1S is no greater than 90 percent of the most stringent 1,1-DCE numeric water quality standard for the currently applicable designated uses or formally proposed designated uses of the canal water into which the SRP well discharges. The treatment process is depicted in Figure 19 and would consist of:

• Using the contingency groundwater extraction wells described in Sections 4.2.3.3 and 4.2.3.4 to extract 1,1-DCE affected groundwater upgradient of the SRP well(s);

• Routing the water to the treatment system location(s) described in Sections 4.2.3.3 and 4.2.3.4;

• Removing solid particulates from the water using cartridge particulate filters;

• Using GAC adsorption to remove 1,1-DCE from the filtered water;

• Sampling and analyzing the treated water to verify the efficacy of the treatment system; and

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 22

Page 29: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

• Discharging the treated water to publicly owned treatment works or underground as reasonable, necessary, cost-effective, and technically feasible to safeguard or achieve the ROs and pursuant to appropriate permitting/licensing.4

The following sections provide a description of the groundwater extraction wells, pumps and piping; treatment system components; treated water discharge; and operation and maintenance of the treatment system in greater detail.

5.1 Groundwater Extraction Wells, Pumps and Piping

The contingency groundwater extraction wells would consist of one pair of 6-inch wells in the D2-Zone and one pair of 6-inch wells in the D3-Zone at locations upgradient of the SRP well for which a Scenario 4 criterion is met (21.5E-1.0S or 20.6E-1.1S), at optimal locations selected in accordance with Section 4.2.3.2.5 Each D2-Zone well would be drilled to a depth of approximately 200 feet bgs and each D3-Zone well would be drilled to a depth of approximately 280 feet. The final depth of the wells would be determined in the field based on the observed hydrogeology.

Variable speed submersible pumps would be placed above or below the well screens, as allowable. Based on hydraulic capture calculations and groundwater modeling, one to two wells pumping at 25 to 50 gallons per minute (gpm) from each zone would capture the majority of the 1,1-DCE affected groundwater within the contingency well area (depicted in Figures 14 and 15).

Each wellhead would be placed within a subsurface precast, heavy traffic rated vault. The wellhead would connect to a 2-inch diameter horizontal PVC and ball valve that transitions to a 2-inch high density polyethylene (HDPE) conveyance pipe. The well vault would house an instrumentation junction box, grounding rod, volts alternating current (VAC) electrical panel with pump disconnect, and leak detection switch.

Two-inch HDPE piping would route the extracted groundwater to the treatment system. The HDPE piping would be installed underground in a trench designed pursuant to City

4 Discharging the treated water into an SRP canal may also occur, provided that the discharge is approved in advance by SRP and subject to (1) the terms and conditions of an agreement with SRP governing such discharge and (2) any applicable AZPDES permit requirements. 5 For purposes of cost estimation for this plan, it is assumed that two pairs of contingency groundwater extraction wells would be required upgradient of one of the two SRP wells (see Appendix B).

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 23

Page 30: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

of Tempe and Maricopa County specifications and backfilled with clean material. A magnetic locating tape would be installed to facilitate future location of the piping.

5.2 Treatment System

The treatment system would be designed to handle up to approximately 200 gpm of combined flow from the extraction wells during normal operation. The treatment system components, depicted in Figure 19, would operate as follows:

• 2-bag cartridge particulate filter housings operated in parallel to remove particulate matter.

• Flow meters and pressure indicators would be used to monitor filter performance.

• The pumped water would be routed to a 5,000 gallon equalization storage tank in order to sustain steady flow through the GAC vessels.

• Two Equova PV® 5000ST GAC vessels,6 capable of handling a maximum flow of 250 gpm, would be operated in a series lead/lag configuration:

o The lead and lag GAC vessels would remove 1,1-DCE utilizing AquaCarb® S Carbon.

o Samples of the GAC-treated water would be collected from vessel outlet sample ports and analyzed for 1,1-DCE. The sampling and analysis would occur as required in the applicable discharge permit.

o If breakthrough occurs,7 the treatment system would be reconfigured with the lag vessel as the lead vessel. Spent GAC from the former lead vessel would then be regenerated and the vessel would serve as a standby vessel.

6 The sizing of the vessels, handling up to 5,000 pounds of GAC, is based on isotherm calculations performed by Equova. 7 Breakthrough would be considered to have occurred when analysis of samples of the treated water indicates the treated water contains 1,1-DCE at a concentration greater than 50 percent of the 1,1-DCE concentration treatment goal (discussed in this Section 5.2, further below).

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 24

Page 31: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

• Potable water would be introduced to backwash the GAC vessels, when necessary. The potable water would be obtained from a fire hydrant and stored in a 4,000 gallon tank.8

The treatment system would be placed on a foundation within secondary containment:

• The foundation would be a specified earth compacted base and rebar reinforced concrete slab on grade. The slab on grade would be approximately 50 feet by 40 feet and 6 inches thick, with 10-inch thickened edges for stable footing.

• The secondary containment would be 28 feet by 15 feet with 2-foot high walls, sized to hold approximately 130 percent of the liquid capacity of one of the GAC vessels plus the displaced volume of other vessel(s) and equipment.

• A shade structure would be included, as well as a security fence with privacy panels designed to blend in with the local architecture.

The current design and costing assumes the treated water would then be conveyed to the City of Tempe sewer line for routing to the publicly owned treatment works pursuant to appropriate permitting/licensing. The goal of treating the extracted groundwater would be to achieve a concentration of 1,1-DCE in the treated water that is no greater than the 1,1-DCE standard, if any, that is applicable to wastewater discharged to the Tempe sewer system, pursuant to the terms and conditions of a wastewater discharge permit issued by the Tempe public works department.

5.3 Operation, Maintenance and Monitoring

Operation, maintenance and monitoring of the treatment system would be conducted in accordance with its OM&M plan. The OM&M plan would include: purpose/ objectives; start-up criteria; shutdown criteria; operating procedures; maintenance procedures and schedule; and performance monitoring procedures. System pressures and flows would be monitored to ensure the system operates as designed. The pumps and instrumentation would be regularly serviced pursuant to manufacturer specifications. Extraction wells specific-capacity would also be periodically tested to determine if redevelopment or chemical treatment of the extraction wells is necessary. Sampling of

8 Backwashing would require at least three carbon bed volumes of water (3,815-gallons) at a relatively high flow rate. Any backwashed water that is discharged or disposed of would be in accordance with the terms and conditions of a wastewater discharge permit issued by the City of Tempe public works department or state and local disposal requirements, as applicable.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 25

Page 32: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

the influent, intermediate and treated process water would be performed to determine the frequency of the GAC backwash, regeneration and reconfiguration and verify that the applicable treatment level is being achieved prior to discharge of the treated water.

6. ESTIMATED REMEDY COSTS

Estimated costs of implementing the Remedy and the Contingency Remedy are provided in Appendix B. The cost summary includes capital costs as well as yearly, five year, and ten year incremental costs. Since the actual remedy time frame is uncertain, the total remedy costs are also uncertain.

7. REFERENCES

ADEQ 2005. Letter from Debra Daniel (ADEQ) to Katy Brantingham (ARCADIS) RE: Comment on the Salt River Project’s (SRP) Arizona Discharge Elimination System (AZPDES) Permit Renewal for Groundwater Discharges to the SRP Canal System. August 2, 2005.

ADEQ. 2007. Letter from Tom D. Domizio (ADEQ) to Raymond Jasper (VTI) RE: Revised Land and Water Use Questionnaire Responses, Former Capitol Castings Facility located in Tempe, Arizona, Site Code: 504426-00. March 9, 2007.

ADEQ. 2009. Proposed Remedial Objectives Report, Former Capitol Castings Site, 5857 South Kyrene Road, Tempe, Arizona. December 2009.

ADEQ. 2010. Letter from Joey Pace (ADEQ) to Raymond Jasper (VTI) RE: Proposed Remedial Objectives Report, Former Capitol Castings Site, 5857 South Kyrene Road, Tempe, Arizona. April 20, 2010.

ADEQ. 2011a. Former Capitol Castings VRP Site – Final RI Report, e-mail communication from Tom Di Domizio (ADEQ), to Raymond Jasper (VTI), informing that ADEQ has formally submitted Final RI into the Administrative Record. April 21, 2011.

ADEQ. 2011b. Letter from Tom Di Domizio (ADEQ) to Raymond Jasper (VTI) RE: Groundwater Model Evaluation Former Capitol Castings Facility 5857 South Kyrene Road Tempe, AZ Site Code: 504426-00. August 12, 2011.ADEQ. 2014. Letter from Joey Pace (ADEQ) to Dr. William Adams (VTI) RE: Review of DRAFT Feasibility Study Report, Former Capitol Castings Facility, Tempe, Arizona, VRP Site Code: 504426-00. July 15, 2014.

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 26

Page 33: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Proposed Remedial Action Plan

Former Capitol Castings Site Tempe, Arizona

ADEQ. 2014. Letter from Joey Pace (ADEQ) to Dr. William Adams (VTI) RE: Review of DRAFT Feasibility Study Report, Former Capitol Castings Facility, Tempe, Arizona, VRP Site Code: 504426-00. July 15, 2014.

ARCADIS. 2006. Letter from Katy Brantingham (ARCADIS) to Tom D. Domizio (ADEQ) RE: Revised Land and Water Use Questionnaire Responses for Former Capitol Castings Facility, ADEQ VRP Site Code: 504426-00. December 21, 2006.

ARCADIS. 2008. Phase II Groundwater Flow and Solute Transport Model Report Former Capitol Castings Facility 5857 South Kyrene Road Tempe, Arizona. October 6, 2008.

ARCADIS. 2010. Final Remedial Investigation Report. Former Capitol Castings Facility 5857 South Kyrene Road Tempe, Arizona. October 25, 2010.

ARCADIS. 2014a. LUST Groundwater Closure Assessment Report, Former Capitol Castings Facility, Tempe, Arizona, ADEQ VRP Site Code: 504426-00. May 30, 2014.

ARCADIS. 2014b. Final Feasibility Study Report, Former Capitol Castings, Tempe, Arizona. October 13, 2014.

ARCADIS 2015. Fourth Quarter 2014 Groundwater Monitoring Report, Former Capitol Castings, Tempe, Arizona, VRP Site Code 504426-00. January 23, 2015.

ADWR. 2006. Salt River Valley Model Geology Update. Modelling Report No. 16. October 10, 2006.

ITRC 2010. Use and Measurement of Mass Flux and Mass Discharge. August 2010.

Laney, R.L., and Hahn, M.E. 1986. Hydrogeology of the Eastern Part of the Salt River Valley Area, Maricopa and Pinal Counties, Arizona. USGS Water Resources Investigations Report 86-4147.4 plates

\\arcadis-us.com\officedata\phoenix-az\env\env\proj\900\905 rio tinto 2\07 tech_projects\_dce\2014-08_prap\deliverables\prap rev 2\2016-02-29 - p-rap rev2.docx 27

Page 34: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Tables

Page 35: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

G:\ENV\ENV\PROJ\900\905 Rio Tinto 2\07 Tech_Projects\_DCE\2014-08_PRAP\Deliverables\PRAP Rev 2\PRAP Report Tables 20160229.xlsx/Table 1-Schedule Page 1 of 1

Table 1Proposed Remedial Action Plan and Contingency Groundwater Monitoring Schedule

Former Capitol Castings Facility, Tempe, Arizona

Groundwater Sampling Frequency

Base Level Level 1 Level 2 Level 3 Level 4

MW-12B S WL -- -- -- -- -- ●MW-13B S WL -- -- -- -- -- ●MW-14 S WL -- -- -- -- -- ●MW-15D D CSM 1/4yrs 1/3yrs 1/3yrs 1/2yrs 1/2yrs ●MW-15D2 D2 CSM 1/4yrs 1/3yrs 1/3yrs 1/2yrs 1/2yrs ●MW-22S S CSM 1/4yrs 1/3yrs 1/3yrs 1/2yrs 1/2yrs ●MW-22D D Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-24D* D Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-24D2 D2 Sentinel 1/yr 2/yr 4/yr 4/yr 4/yr ●MW-24D3 D3 Sentinel# 2/yr 2/yr 4/yr 4/yr 4/yr ●MW-25S S WL -- -- -- -- -- ●MW-26D D CSM 1/4yrs 1/3yrs 1/3yrs 1/2yrs 1/2yrs ●MW-26D2 D2 CSM 1/4yrs 1/3yrs 1/3yrs 1/2yrs 1/2yrs ●MW-26D3 D3 CSM 1/4yrs 1/3yrs 1/3yrs 1/2yrs 1/2yrs ●MW-27D D WL -- -- -- -- -- ●MW-28D D WL -- -- -- -- -- ●MW-28D2 D2 CSM 1/4yrs 1/3yrs 1/3yrs 1/2yrs 1/2yrs ●MW-28D3 D3 WL -- -- -- -- -- ●MW-29D D CSM 1/4yrs 1/3yrs 1/3yrs 1/2yrs 1/2yrs ●MW-29D2 D2 Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-29D3 D3 Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-29D3b D3 CSM 1/4yrs 1/3yrs 1/3yrs 1/2yrs 1/2yrs ●MW-30D3 D3 WL -- -- -- -- -- ●MW-32D D Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-32D2 D2 Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-32D3 D3 Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-33D2 D2 Sentinel 1/yr 2/yr 4/yr 4/yr 4/yr ●MW-33D3 D3 Sentinel# 2/yr 2/yr 4/yr 4/yr 4/yr ●MW-33D4 D4 Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-34D2 D2 Sentinel 1/yr 2/yr 4/yr 4/yr 4/yr ●MW-34D3 D3 Sentinel# 2/yr 2/yr 4/yr 4/yr 4/yr ●MW-36A2 A2 Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-36D2 D2 Sentinel 1/yr 2/yr 4/yr 4/yr 4/yr ●MW-36D3 D3 Sentinel# 2/yr 2/yr 4/yr 4/yr 4/yr ●MW-38D2 D2 Sentinel 1/yr 2/yr 4/yr 4/yr 4/yr ●MW-38D3 D3 Sentinel# 2/yr 2/yr 4/yr 4/yr 4/yr ●MW-39D2 D2 Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●MW-39D3 D3 Key 1/2yrs 1/yr 1/yr 2/yr 2/yr ●Contingency wells D2/D3 Contingency -- -- 4/yr 4/yr 4/yr ●SRP Well 20.6E-1.1S A2-D3 SRP 1/yr 1/yr 2/yr 2/yr 4/yr ◊SRP Well 21.5E-1.0S D2-D4 SRP 1/yr 1/yr 2/yr 2/yr 4/yr ◊Notes:Groundwater samples will be collected using hydrasleeves per P-RAPSRP well water samples will be collected from the SRP well dischargeAll groundwater samples will be analyzed for 1,1-dichloroethene only using method USEPA 8260BGroundwater Monitoring Frequencies:

1/4yrs = once every 4 years 1/yr = once a year1/3yrs = once every 3 years 2/yr = twice a year1/2yrs = once every 2 years 4/yr = four times a year

Aquifer (zone) definitions (describes which zone(s) wells are screened within):S = S-Zone D = D-ZoneD2 = D2-Zone A2 = A2-ZoneD3 = D3-Zone D4 = D4-Zone

-- = not scheduled for monitoring* = piezometer well - sample using bailer# = D3-Zone sentinel wells monitored 2/yr during Base Level monitoring● = water level measurement frequency based on sentinel well monitoring frequency (e.g. 1/yr at Base Level) ◊ = water levels (as allowable) and pumping monitoringCSM = conceptual site model well as designated in the P-RAPKey = key monitoring well as desiganted in the P-RAPSentinel = sentinel monitoring well as designated in the P-RAPContingency = contingency sentinel/extraction well as designated in the P-RAPWL = water levels only monitoring well as designated in the P-RAP

Water Level Monitoring

P-RAP Use DesignationWell Identification Aquifer

(Zone)

Page 36: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Table 2Current and Foreseeable Designated Water Uses and Numeric Water Quality Standards

Former Capitol Castings Facility, Tempe, Arizona

Water Quality Standard1,1-DCE Numeric Water

Quality Standard Applicable to Water Use

Western Canal Water

High Line Canal Water

Kiwanis Park Lake Water

ME Global Well Water

Domestic water source (DWS) 7 µg/L4 Foreseeable designated use1

Foreseeable designated use1 -- --

Full-body contact (FBC)3 46,667 µg/L -- -- Current designated use --

Partial-body contact (PBC)3 46,667 µg/L -- -- Current designated use

Current use exposure pathway

Aquatic and wildlife warm water accute (A&Ww)3 15,000 µg/L5 -- -- Current

designated use --

Aquatic and wildlife warm water chronic (A&Ww)3 950 µg/L6 -- -- Current

designated use --

Agricultural irrigation (AgI)2 n/a7 Current designated use

Current designated use

Current designated use --

Agricultural livestock watering (AgL)2 n/a7 Current designated use

Current designated use -- --

Notes:

1 =

2 = This designated use is applicable to all Phoenix area canals. A.A.C. Chapter 11, Article 1, Appendix B; 14 Ariz. Admin Reg. 4708, 4911 (December 26, 2008).3 = This designated use is applicable to Kiwanis Park Lake. A.A.C. Chapter 11, Article 1, Appendix B; 14 Ariz. Admin Reg. 4708, 4911 (December 26, 2008).

4 =

5 =

6 =

7 =

Abbreviations:1,1-DCE = 1,1-dichloroethene

n/a = no applicable standardµg/L = micrograms per liter-- = no current or foreseeable designated use

This foreseeable use is based on the ADEQ-approved land and water use study (ARCADIS 2006, ADEQ 2006) and ADEQ-approved remedial investigation (RI)/remedial objective (RO) report (ARCADIS 2010, ADEQ 2011).

This is the Arizona surface water quality standard for chronic toxicity exposure of A&Ww to 1,1-DCE. A.A.C. Chapter 11, Article 1, Appendix B; 14 Ariz. Admin Reg. 4708, 4873 (December 26, 2008).

This is the Arizona surface water quality standard and U.S. EPA maximum contaminant level (MCL) for 1,1-DCE in drinking water. A.A.C. Chapter 11, Article 1, Appendix B; 14 Ariz. Admin Reg. 4708, 4873 (December 26, 2008).This is the Arizona surface water quality standard for acute toxicity exposure of A&Ww to 1,1-DCE. A.A.C. Chapter 11, Article 1, Appendix B; 14 Ariz. Admin Reg. 4708, 4873 (December 26, 2008).

There is no numeric water quality standard applicable to 1,1-DCE in water used for AgI or AgL. A.A.C. Chapter 11, Article 1, Appendix B; 14 Ariz. Admin Reg. 4708, 4873 (December 26, 2008).

Page 37: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Figures

Page 38: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

!(

!(

!(

!(WS-1

SRP-21.5E-1.5S

SRP-21.5E-1.0S

SRP-21.1E-0.0S

SRP-20.6E-1.1S

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 01 facility location map.mxd 6/24/2015

NOTES· Aerial photo source: ESRI World Imagery.

LEGEND

£Scale: 1" = 2,000'

Feet0 1,000 2,000

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

FACILITY LOCATIONFIGURE

1

^

ARIZONA

Western Canal

Former facility boundary

!( Water supply well(within ½ mile of the Site)

§̈¦10

S Kyre

ne Rd

S Rur

al Rd

S McC

lintoc

k Dr

W Guadalupe Rd

W Baseline Rd

Scale: 1" = 300 miles£

North Branch Highline Canal

Page 39: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

#*

#*

")")

") !(

!(

!(

!(

!(

!(

!(

!(!(

!(!(!( !(

!(

!(!(

!(

!(

!(

!(!(

!(!(

!(

!(

!(!(

!(

!(

!(!(

!(!(

!(!(

!(!(!(

!(

!(!(

!(

!(

!(

!(

!(

!(

!(

#*

!(

MW-39D2MW-39D3

MW-38DMW-38D2MW-38D3

WS-1

VE-1

MW-37

MW-23

MW-21

MW-20

MW-19

MW-17

MW-16

MW-15

MW-14

MW-11 MW-10

MW-09

MW-08MW-07

MW-06

MW-05

MW-04

MW-03

MW-02

IW-02IW-01

EW-01

MW-32D

MW-13B

MW-12B

MW-09B

MW-33D4

MW-29D3b

SRP-21.5E-1.0S

IW-03

EW-02CC-01

MW-27SMW-27D

MW-26SMW-26D

MW-25SMW-25D

MW-36DMW-36A2

MW-35DMW-35D2

MW-15DMW-15D2

MW-36D2MW-36D3

MW-34D2MW-34D3

MW-33D2MW-33D3

MW-32D2MW-32D3

MW-26D2MW-26D3

MW-31DMW-31D2 MW-30D

MW-30D3

MW-22SMW-22MMW-22D

MW-29DMW-29D2MW-29D3

MW-28DMW-28D2MW-28D3

MW-24DMW-24D2MW-24D3

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 02 well location map.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

FIGURE

NOTES· Aerial photo source: ESRI World Imagery.

!(

£Scale: 1" = 300'

Feet0 150 300

LEGEND

Kiwanis Lake

")

#*

#*

!(

Groundwater monitoring well

Groundwater injection well

Groundwater extraction well

Soil vapor extraction well

Water supply well

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

2

MONITORING WELL LOCATIONS

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

W Orion St

W Gemini Dr

Former facility boundary

Page 40: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

#*

#*

") !(

!(

!(

!(

!(

!(

!(

!(!(

!(!(!( !(

!(

!(

!(

!(

!(

!(

!(!(!(

!(

!(

!(

!(

!(

!(

MW-19NS

MW-17NS

MW-16NS

MW-09NS

MW-27SNS

MW-13BNS

EW-02Nov '14 = <5.0Apr '14 = <10Nov '13 = <5.0Aug '13 = <1.0May '13 = <10Mar '13 = <10Dec '12 = <20

WS-1

SRP-21.5E-1.0S

MW-14Nov '14 = 1.6Apr '14 = 1.9Nov '13 = 1.1Aug '13 = 4.2May '13 = 4.9Mar '13 = 7.1Dec '12 = 10

MW-07Nov '14 = <1.0Apr '14 = <10Nov '13 = <5.0Aug '13 = <100May '13 = <10Mar '13 = <10Dec '12 = <10

IW-03Nov '14 = <1.0Apr '14 = <10Nov '13 = <5.0Aug '13 = <1.0May '13 = <10Mar '13 = <10Dec '12 = <1.0

CC-01Nov '14 = <1.0Apr '14 = <2.0Nov '13 = <5.0Aug '13 = <1.0May '13 = <5.0Mar '13 = <5.0Dec '12 = <10

MW-09BNov '14 = <1.0Apr '14 = <1.0Nov '13 = <1.0Aug '13 = <1.0May '13 = <1.0Mar '13 = <1.0Dec '12 = <1.0

MW-25SNov '13 = 3.6Nov '12 = 3.6

MW-05Nov '13 = <1.0Dec '12 = <1.0

EW-01Nov '13 = <1.0Dec '12 = <1.0

MW-26SNov '13 = <1.0Nov '12 = <1.0

MW-12BNov '13 = <1.0Nov '12 = <1.0

MW-08Nov '13 = <1.0Dec '12 = <1.0

MW-10Nov '13 = 4.0May '13 = 4.9Dec '12 = 8.0

MW-15Nov '13 = 13Dec '12 = 7.6

MW-22SNov '13 = 22Aug '13 = 27May '13 = 27Mar '13 = 28Dec '12 = 29

MW-37Nov '13 = <5.0Aug '13 = <100May '13 = <10Mar '13 = <10Dec '12 = <1.0

MW-06Nov '13 = <1.0Aug '13 = <1.0May '13 = <1.0Mar '13 = <1.0Dec '12 = <1.0

MW-04Nov '13 = <1.0Aug '13 = <1.0May '13 = <1.0Mar '13 = <1.0Dec '12 = <1.0

MW-03Nov '13 = <1.0Aug '13 = <1.0May '13 = <1.0Mar '13 = <1.0Dec '12 = <1.0

MW-02Nov '13 = <1.0Aug '13 = <1.0May '13 = <1.0 UJMar '13 = <1.0Dec '12 = <1.0

MW-20Nov '13 = 6.1Dec '12 = 5.4

MW-23Nov '13 = 1.7Nov '12 = 4.2

MW-11Nov '13 = 8.9Aug '13 = 10May '13 = 12Mar '13 = 12Dec '12 = 11

MW-22MNov '13 = 13Aug '13 = 18May '13 = 12Mar '13 = 17Dec '12 = 15

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 03 11DCE concentrations S Q4 2014.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

FIGURE

NOTES· Aerial photo source: ESRI World Imagery.· 1,1-DCE = 1,1-dichloroethene.· 1,1-DCE concentrations are expressed in micrograms per liter (µg/L).· Wells were sampled from 10/28/2014 to 11/6/2014 (results displayed in blue).· Arizona Aquifer Water Quality Standard (AWQS) for 1,1-DCE = 7 µg/L.

!(

£Scale: 1" = 300'

Feet0 150 300

LEGEND

Kiwanis Lake

")

#*

!(

Groundwater monitoring wellGroundwater injection wellGroundwater extraction wellWater supply well

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

2014 1,1-DCE concentration contour(if applicable; dashed = inferred)

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

DISTRIBUTION OF 1,1-DCE IN THE S-ZONE WITHTWO-YEAR SUMMARY OF 1,1-DCE CONCENTRATIONS

3

MW-14Dec '12 = 10Nov '11 = 2.2Nov '10 = 7.9

MW-20Dec '12 = 5.4Nov '11 = 4.5Nov '10 = 8.8

Well ID and 1,1-DCE concentrations(Q4 2014 monitoring event in blue)

Well ID and 1,1-DCE concentrations(deeper screen construction; not used in contouring)

<1.0 1,1-DCE not detected above indicatedlaboratory detection limit

J / UJ 1,1-DCE concentration estimated(+ indicates estimated high; - indicates estimated low)

7

NS Well not sampled

W Orion St

W Gemini Dr

Page 41: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

")")

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(

!(

!(

!(

!(

!(

IW-02NS

IW-01NS

WS-1

SRP-21.5E-1.0S

MW-38DNov '14 = <1.0

MW-21Nov '13 = 1.1Dec '12 = 2.4

MW-35DNov '13 = 370Dec '12 = 680

MW-31DNov '13 = 270Nov '12 = 450

MW-36DNov '13 = <1.0Nov '12 = <1.0

MW-27DNov '13 = <1.0Nov '12 = <1.0

MW-30DNov '13 = 390Dec '12 = 580

MW-25DNov '13 = 120 J+Nov '12 = 170

MW-22DNov '13 = 12May '13 = 7.8Dec '12 = 7.5

MW-15DNov '14 = 690Apr '14 = 870Nov '13 = 610Dec '12 = 730

MW-24DNov '13 = <1.0May '13 = <1.0Nov '12 = <1.0

MW-29DOct '14 = <1.0Apr '14 = <1.0Nov '13 = <1.0Nov '12 = <1.0

MW-28DOct '14 = 2.2Apr '14 = 1.8Nov '13 = 2.7May '13 = 2.3Nov '12 = 2.6

MW-26DOct '14 = 290Apr '14 = 370Nov '13 = 240May '13 = 250Dec '12 = 390

MW-32DOct '14 = <1.0Apr '14 = <1.0Nov '13 = <1.0May '13 = <1.0Nov '12 = <1.0

7

100

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 04 11DCE concentrations D Q4 2014.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

FIGURE

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

DISTRIBUTION OF 1,1-DCE IN THE D-ZONE WITHTWO-YEAR SUMMARY OF 1,1-DCE CONCENTRATIONS

4

NOTES· Aerial photo source: ESRI World Imagery.· 1,1-DCE = 1,1-dichloroethene.· 1,1-DCE concentrations are expressed in micrograms per liter (µg/L).· Wells were sampled from 10/28/2014 to 11/6/2014 (results displayed in blue).· Arizona Aquifer Water Quality Standard (AWQS) for 1,1-DCE = 7 µg/L.

!(

£Scale: 1" = 300'

Feet0 150 300

LEGEND

Kiwanis Lake

")

#*

!(

Groundwater monitoring wellGroundwater injection wellGroundwater extraction wellWater supply well2014 1,1-DCE concentration contour(if applicable; dashed = inferred)

Well ID and 1,1-DCE concentrations(Q4 2014 monitoring event in blue)

Well ID and 1,1-DCE concentrations(deeper screen construction; not used in contouring)

<1.0 1,1-DCE not detected above indicatedlaboratory detection limit

J / UJ 1,1-DCE concentration estimated(+ indicates estimated high; - indicates estimated low)

7

MW-14Dec '12 = 10Nov '11 = 2.2Nov '10 = 7.9

MW-20Dec '12 = 5.4Nov '11 = 4.5Nov '10 = 8.8

NS Well not sampled

W Orion St

W Gemini Dr

Page 42: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

!(

!( !(

!(

!(

!(

!(!(

!(

!(!(

!(

!(

!(

!(WS-1

SRP-21.5E-1.0S

MW-34D2Nov '14 = <1.0Apr '14 = 1.1Nov '13 = 1.9Aug '13 = 2.7May '13 = 3.5Mar '13 = 4.7Nov '12 = 3.9

MW-36D2Oct '14 = <1.0 UJApr '14 = <1.0Nov '13 = <1.0Aug '13 = <1.0May '13 = <1.0Mar '13 = <1.0Nov '12 = <1.0

MW-24D2Oct '14 = <1.0 UJApr '14 = <1.0Nov '13 = <1.0Aug '13 = <1.0 UJMay '13 = <1.0Mar '13 = <1.0Nov '12 = <1.0

MW-33D2Oct '14 = <1.0Jul '14 = <1.0Apr '14 = <1.0Nov '13 = <1.0Aug '13 = <1.0May '13 = <1.0Mar '13 = <1.0Nov '12 = <1.0

MW-31D2Nov '13 = 48Nov '12 = 38

MW-35D2Nov '13 = 48 J+Dec '12 = 60

MW-15D2Nov '14 = 37Apr '14 = 30Nov '13 = 30Dec '12 = 22

MW-29D2Oct '14 = <1.0Apr '14 = <1.0Nov '13 = <1.0Nov '12 = <1.0

MW-38D2Oct '14 = 22Jul '14 = 22Apr '14 = 20Jan '14 = 28Dec '13 = 25

MW-28D2Oct '14 = 49Apr '14 = 46Nov '13 = 49May '13 = 26Nov '12 = 16

MW-26D2Oct '14 = 22Apr '14 = 29Nov '13 = 33May '13 = 16Nov '12 = 13

MW-32D2Oct '14 = 3.9Apr '14 = 3.5Nov '13 = 3.8May '13 = 2.2Nov '12 = 2.4

MW-39D2Nov '14 = <1.0Jul '14 = <1.0Apr '14 = <1.0Jan '14 = <1.0Dec '13 = <1.0

MW-36A2Nov '13 = <1.0May '13 = <1.0Nov '12 = <1.0

7

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 05 11DCE concentrations D2 Q4 2014.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

FIGURE

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

DISTRIBUTION OF 1,1-DCE IN THE D2-ZONE WITHTWO-YEAR SUMMARY OF 1,1-DCE CONCENTRATIONS

5

NOTES· Aerial photo source: ESRI World Imagery.· 1,1-DCE = 1,1-dichloroethene.· 1,1-DCE concentrations are expressed in micrograms per liter (µg/L).· Wells were sampled from 10/28/2014 to 11/6/2014 (results displayed in blue).· Arizona Aquifer Water Quality Standard (AWQS) for 1,1-DCE = 7 µg/L.

!(

LEGEND

Kiwanis Lake

")

#*

!(

Groundwater monitoring wellGroundwater injection wellGroundwater extraction wellWater supply well2014 1,1-DCE concentration contour(if applicable; dashed = inferred)

Well ID and 1,1-DCE concentrations(Q4 2014 monitoring event in blue)

Well ID and 1,1-DCE concentrations(deeper screen construction; not used in contouring)

<1.0 1,1-DCE not detected above indicatedlaboratory detection limit1,1-DCE concentration estimated(+ indicates estimated high; - indicates estimated low)

7

MW-14Dec '12 = 10Nov '11 = 2.2Nov '10 = 7.9

MW-20Dec '12 = 5.4Nov '11 = 4.5Nov '10 = 8.8

J / UJ

Well not sampled

W Orion St

W Gemini Dr

NS

£Scale: 1" = 300'

Feet0 150 300

Page 43: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

!( !(

!(!(

!(

!(

!(!(!( !(

!(

!(

!(

!(WS-1

SRP-21.5E-1.0S

MW-36D3Oct '14 = 26Apr '14 = 22Nov '13 = 18Aug '13 = 15May '13 = 12Mar '13 = 12Nov '12 = 6.7

MW-24D3Oct '14 = 5.5 JApr '14 = 3.2Nov '13 = 3.5Aug '13 = 2.9May '13 = 3.3Mar '13 = 4.5Nov '12 = 5.1

MW-34D3Nov '14 = 1.5Apr '14 = <1.0Nov '13 = 8.5Aug '13 = <1.0May '13 = 1.9Mar '13 = <1.0Nov '12 = 1.4

MW-33D3Oct '14 = <1.0Jul '14 = <1.0Apr '14 = <1.0Nov '13 = <1.0Aug '13 = <1.0May '13 = <1.0Mar '13 = <1.0Nov '12 = <1.0

MW-30D3Nov '14 = <1.0Apr '14 = <1.0Nov '13 = <1.0Nov '12 = <1.0

MW-28D3Oct '14 = <1.0Apr '14 = <1.0Nov '13 = <1.0Nov '12 = <1.0

MW-38D3Oct '14 = 22 JJul '14 = 21Apr '14 = 19Jan '14 = 20Dec '13 = 16

MW-26D3Oct '14 = 7.3 JApr '14 = 14Nov '13 = 14May '13 = 21Nov '12 = 21

MW-29D3Oct '14 = 5.7Apr '14 = 14Nov '13 = 8.7May '13 = 15Nov '12 = 20

MW-39D3Nov '14 = 1.2Jul '14 = 2.5Apr '14 = 2.7Jan '14 = 5.5Dec '13 = 3.4

MW-32D3Oct '14 = 1.1Apr '14 = 1.7Nov '13 = <1.0May '13 = <0.50Nov '12 = <1.0

MW-29D3BNov '13 = <1.0Nov '12 = <1.0

MW-33D4Oct '14 = <1.0Apr '14 = <1.0Nov '13 = <1.0Nov '12 = <1.0

7

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 06 11DCE concentrations D3 Q4 2014.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

FIGURE

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

DISTRIBUTION OF 1,1-DCE IN THE D3-ZONE WITHTWO-YEAR SUMMARY OF 1,1-DCE CONCENTRATIONS

6

NOTES· Aerial photo source: ESRI World Imagery.· 1,1-DCE = 1,1-dichloroethene.· 1,1-DCE concentrations are expressed in micrograms per liter (µg/L).· Wells were sampled from 10/28/2014 to 11/6/2014 (results displayed in blue).· Arizona Aquifer Water Quality Standard (AWQS) for 1,1-DCE = 7 µg/L.

!(

LEGEND

Kiwanis Lake

")

#*

!(

Groundwater monitoring wellGroundwater injection wellGroundwater extraction wellWater supply well2014 1,1-DCE concentration contour(if applicable; dashed = inferred)

Well ID and 1,1-DCE concentrations(Q4 2014 monitoring event in blue)

Well ID and 1,1-DCE concentrations(deeper screen construction; not used in contouring)

<1.0 1,1-DCE not detected above indicatedlaboratory detection limit

NS Well not sampled

7

MW-14Dec '12 = 10Nov '11 = 2.2Nov '10 = 7.9

MW-20Dec '12 = 5.4Nov '11 = 4.5Nov '10 = 8.8

J / UJ 1,1-DCE concentration estimated(+ indicates estimated high; - indicates estimated low)

W Orion St

W Gemini Dr

£Scale: 1" = 300'

Feet0 150 300

Page 44: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Hydrogeologic Cross-Section and Vertical Distribution of 1,1-DCE

(North-South) South

Distance (feet)

Ele

vatio

n (fe

et a

bove

mea

n se

a le

vel)

North

Vertical Exaggeration = 4:1

Proposed Remedial Action Plan Former Capitol Castings, Tempe, Arizona

7 ug/L

Orion St

Gemini Dr

Julie Dr

Ash

Ave

Former Capitol Castings N

Maple Ave Guadalupe Rd

Rai

l Roa

d Tr

acks

= Current monitoring well location

A

A’

Cross-Section Location:

S

D

A

D2

A2

D3

Legend:

= Monitoring Well

7.6 = Concentration of 1,1-DCE in ug/L (Fourth Quarter 2014) = Not detected above specified laboratory reporting limit

< 1

= 1,1-dichloroethene 1,1-DCE

= Designated aquifer S, D, A

FIGURE

07

A A’

= Micrograms per liter ug/L

= Approximate water table

100 ug/L

7.3

< 1.0

1.1

NS

1.5

<1.0

< 1.0

<1.0

3.9 37

690 290

22

Page 45: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

#*

#*

") !(

!(

!(

!(

!(

!(

!(

!(!(

!(!(!( !(

!(

!(

!(

!(

!(

!(

!(!(!(

!(

!(

!(

!(

!(

!(

1117

MW-10NM

MW-09NM

MW-02NM

EW-01NM

MW-371124.01

MW-191125.27

MW-171124.52

MW-161125.90

MW-151121.98

MW-141122.98

MW-071123.77

MW-051124.14

MW-041123.54

MW-27S1112.75

MW-26S1116.88

MW-25S1121.17

MW-22S1122.08 MW-13B

1123.54MW-12B1122.25

MW-081123.43

MW-061124.19MW-03

1124.05IW-031123.81

EW-021123.60CC-01

1123.99

MW-09B1123.21

WS-1

SRP-21.5E-1.0S

MW-201122.25

MW-111121.44

MW-231121.07

MW-22M1118.28

1124

1125

1123

1122

1121112011191118

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 08 GW elevations S Q4 2014.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

FIGURE

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

GROUNDWATER ELEVATION CONTOURSS-ZONE

8

NOTES· Aerial photo source: ESRI World Imagery.· Groundwater elevations are expressed in feet above mean sea level (ft amsl) in City of Tempe Vertical Datum.· Depths to groundwater were measured on 10/27/2014.

!(

LEGEND

")

#*

!(

Groundwater monitoring wellGroundwater injection wellGroundwater extraction wellWater supply wellGroundwater elevation contour(approximate)

MW-051124.14

MW-231121.07

Well ID and groundwater elevation

Well ID and groundwater elevation(deeper screen construction; not used in contouring)

* Groundwater elevation is anomalousand is not used in contouring

NM Groundwater elevation not measured

1122Kiwanis Lake

Approximate groundwater flow direction

W Orion St

W Gemini Dr

£Scale: 1" = 300'

Feet0 150 300

Page 46: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

")")

!(

!(

!(

!(

!(

!(

!(

!(

!(

!(!(

!(

!(

!(

!(

!(

!(

IW-02NMIW-01

NM

MW-211093.65

MW-38D1094.12 MW-36D

1095.91

MW-35D1093.41

MW-32D1093.58

MW-31D1093.47

MW-29D1093.74

MW-28D1093.14

MW-27D1093.98

MW-26D1093.38

MW-24D1093.77

MW-22D1093.76

MW-15D1093.57

MW-30D1093.54

MW-25D1093.56

WS-1

SRP-21.5E-1.0S

1094

1095

1094

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 09 GW elevations D Q4 2014.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

FIGURE

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

GROUNDWATER ELEVATION CONTOURSD-ZONE

9

NOTES· Aerial photo source: ESRI World Imagery.· Groundwater elevations are expressed in feet above mean sea level (ft amsl) in City of Tempe Vertical Datum.· Depths to groundwater were measured on 10/27/2014.

!(

LEGEND

")

#*

!(

Groundwater monitoring wellGroundwater injection wellGroundwater extraction wellWater supply wellGroundwater elevation contour(approximate)

MW-211093.65

MW-231121.07

Well ID and groundwater elevation

Well ID and groundwater elevation(deeper screen construction; not used in contouring)

* Groundwater elevation is anomalousand is not used in contouring

NM Groundwater elevation not measured

1122

Approximate groundwater flow direction

Kiwanis Lake

W Orion St

W Gemini Dr

£Scale: 1" = 300'

Feet0 150 300

Page 47: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

!(

!( !(

!(

!(

!(

!(!(

!(

!(!(

!(

!(

!(

!(

1082

1084

1083

1081

MW-39D21080.67

MW-38D21079.96 MW-36D2

1082.85

MW-35D21081.72

MW-34D21080.85

MW-33D21081.45

MW-32D21081.50

MW-31D21081.61

MW-29D21084.87

MW-28D21082.72

MW-26D21081.48

MW-24D21080.39

MW-15D21081.56

MW-36A21079.33

WS-1

SRP-21.5E-1.0S

1081

1082

1083

1084

1080

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 10 GW elevations D2 Q4 2014.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

FIGURE

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

GROUNDWATER ELEVATION CONTOURSD2-ZONE

10

NOTES· Aerial photo source: ESRI World Imagery.· Groundwater elevations are expressed in feet above mean sea level (ft amsl) in City of Tempe Vertical Datum.· Depths to groundwater were measured on 10/27/2014.

!(

LEGEND

")

#*

!(

Groundwater monitoring wellGroundwater injection wellGroundwater extraction wellWater supply wellGroundwater elevation contour(approximate)

MW-36D21082.85

MW-36A21079.33

Well ID and groundwater elevation

Well ID and groundwater elevation(deeper screen construction; not used in contouring)

* Groundwater elevation is anomalousand is not used in contouring

NM Groundwater elevation not measured

1122Kiwanis Lake

Approximate groundwater flow direction

W Orion St

W Gemini Dr

£Scale: 1" = 300'

Feet0 150 300

Page 48: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

!( !(

!(!(

!(

!(

!(!(!( !(

!(

!(

!(

!(

1074

1075

1074

10741075

1073

MW-39D31073.09

MW-38D31075.33 MW-36D3

1075.15MW-34D31073.59

MW-33D31072.94

MW-32D31074.86

MW-30D31076.13

MW-29D31074.35

MW-28D31075.69

MW-26D31075.60

MW-24D31075.70

MW-33D41072.58

MW-29D3b1074.44

WS-1

SRP-21.5E-1.0S

1076

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 11 GW elevations D3 Q4 2014.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

FIGURE

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

GROUNDWATER ELEVATION CONTOURSD3-ZONE

11

NOTES· Aerial photo source: ESRI World Imagery.· Groundwater elevations are expressed in feet above mean sea level (ft amsl) in City of Tempe Vertical Datum.· Depths to groundwater were measured on 10/27/2014.

!(

LEGEND

")

#*

!(

Groundwater monitoring wellGroundwater injection wellGroundwater extraction wellWater supply wellGroundwater elevation contour(approximate)

MW-33D31081.45

MW-33D41072.58

Well ID and groundwater elevation

Well ID and groundwater elevation(deeper screen construction; not used in contouring)

* Groundwater elevation is anomalousand is not used in contouring

NM Groundwater elevation not measured

1122Kiwanis Lake

Approximate groundwater flow direction

W Orion St

W Gemini Dr

£Scale: 1" = 300'

Feet0 150 300

Page 49: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!( !(

!(

!(

!(

!(

MW-12B

MW-25S

MW-13B

SRP-21.5E-1.0S

MW-14MW-22S22*

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 12 groundwater monitoring network S.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

NOTES· Aerial photo source: ESRI World Imagery.· 1,1-DCE = 1,1-dichloroethene.· 1,1-DCE concentrations are expressed in micrograms per liter (µg/L).· Arizona Aquifer Water Quality Standard (AWQS) for 1,1-DCE = 7 µg/L.· 1 = CSM wells monitor the core area of the 1,1-DCE affected groundwater.· 2 = Key wells monitor primary transport pathways.· 3 = Sentinel wells monitor primary transport pathway upgradient from the SRP wells.· 4 = Displayed 1,1-DCE concentration represents the highest concentration detected in the S-zone in Q4 2014.· * = Displayed 1,1-DCE concentration is from November 2013.

!(

£Scale: 1" = 400'

Feet0 200 400

LEGEND

Kiwanis Lake

!(

CSM (Conceptual Site Model) well 1Key well 2Sentinel well 3Water supply well

S Maple Ave

S All American Way

W Orion St

W Gemini Dr

1,1-DCE concentration contour(dashed = inferred)

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

1,1-DCE REMEDIAL ACTION PLANGROUNDWATER MONITORING NETWORK (S-ZONE)

MW-13B Well ID

7

W Cornell Dr

S Ash

Ave

S For

est A

ve

!(

!(

!( Water level well

MW-141.6

Well ID and 1,1-DCE concentration 4(Q4 2014 concentration unless indicated otherwise)

W Julie Dr

W Orion St

W Gemini Dr

7

FIGURE

12

1,700 feet west toSRP well 20.6E-1.1S

Page 50: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

!(

!(

!(

!(

!(!(

!(

MW-32D MW-29D

MW-26D

MW-24D

MW-22D

SRP-21.5E-1.0S

MW-15D690

MW-27D

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 13 groundwater monitoring network D.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

Kiwanis LakeS Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Cornell Dr

S Ash

Ave

S For

est A

ve

NOTES· Aerial photo source: ESRI World Imagery.· 1,1-DCE = 1,1-dichloroethene.· 1,1-DCE concentrations are expressed in micrograms per liter (µg/L).· Arizona Aquifer Water Quality Standard (AWQS) for 1,1-DCE = 7 µg/L.· 1 = CSM wells monitor the core area of the 1,1-DCE affected groundwater.· 2 = Key wells monitor primary transport pathways.· 3 = Sentinel wells monitor primary transport pathway upgradient from the SRP wells.· 4 = Displayed 1,1-DCE concentration represents the highest concentration detected in the D-zone in Q4 2014.

!(

LEGEND

!(

CSM (Conceptual Site Model) well 1Key well 2Sentinel well 3Water supply well

1,1-DCE concentration contour(dashed = inferred)

MW-22D Well ID

7

!(

!(

!( Water level well

MW-15D690

Well ID and 1,1-DCE concentration 4(Q4 2014 concentration unless indicated otherwise)

W Julie Dr

W Orion St

W Gemini Dr

£Scale: 1" = 400'

Feet0 200 400

7

100

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

1,1-DCE REMEDIAL ACTION PLANGROUNDWATER MONITORING NETWORK (D-ZONE)

FIGURE

13

1,700 feet west toSRP well 20.6E-1.1S

Page 51: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

!(

!( !(

!(!(

!(!( !(!(!(

!(

!(

MW-39D2

MW-38D2 MW-36D2

MW-36A2

MW-34D2 MW-33D2

MW-32D2 MW-29D2

MW-26D2

MW-24D2

MW-15D2

SRP-21.5E-1.0S

MW-28D249

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 14 groundwater monitoring network D2.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

Kiwanis LakeS Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Julie Dr

W Orion St

W Gemini Dr

W Cornell Dr

S Ash

Ave

S For

est A

ve

NOTES· Aerial photo source: ESRI World Imagery.· 1,1-DCE = 1,1-dichloroethene.· 1,1-DCE concentrations are expressed in micrograms per liter (µg/L).· Arizona Aquifer Water Quality Standard (AWQS) for 1,1-DCE = 7 µg/L.· 1 = CSM wells monitor the core area of the 1,1-DCE affected groundwater.· 2 = Key wells monitor primary transport pathways.· 3 = Sentinel wells monitor primary transport pathway upgradient from the SRP wells.· 4 = Displayed 1,1-DCE concentration represents the highest concentration detected in the D2-zone in Q4 2014.

!(

LEGEND

!(

CSM (Conceptual Site Model) well 1Key well 2Sentinel well 3Water supply well

1,1-DCE concentration contour(dashed = inferred)

MW-15D2 Well ID

7

!(

!(

!( Water level well

MW-28D249

Well ID and 1,1-DCE concentration 4(Q4 2014 concentration unless indicated otherwise)

Contingency well area

£Scale: 1" = 400'

Feet0 200 400

7

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

1,1-DCE REMEDIAL ACTION PLANGROUNDWATER MONITORING NETWORK (D2-ZONE)

FIGURE

14

1,700 feet west toSRP well 20.6E-1.1S

Page 52: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

!(

!(

!(!(!(

!(!(!( !(!(

!(

!(

MW-39D3

MW-38D3MW-34D3 MW-33D4MW-33D3

MW-32D3 MW-29D3

MW-26D3

MW-24D3MW-29D3B

SRP-21.5E-1.0S

MW-36D326

\\Scottsdale-AZ\OfficeData\Project\Capitol Castings\GIS\Projects\Proposed RAP 03-2015\Figure 15 groundwater monitoring network D3.mxd 6/24/2015

Western Canal

S Kyre

ne Rd

W Guadalupe Rd

Kiwanis LakeS Maple Ave

S All American Way

W Orion St

W Gemini Dr

W Cornell Dr

S Ash

Ave

S For

est A

ve

NOTES· Aerial photo source: ESRI World Imagery.· 1,1-DCE = 1,1-dichloroethene.· 1,1-DCE concentrations are expressed in micrograms per liter (µg/L).· Arizona Aquifer Water Quality Standard (AWQS) for 1,1-DCE = 7 µg/L.· 1 = CSM wells monitor the core area of the 1,1-DCE affected groundwater.· 2 = Key wells monitor primary transport pathways.· 3 = Sentinel wells monitor primary transport pathway upgradient from the SRP wells.· 4 = Displayed 1,1-DCE concentration represents the highest concentration detected in the D3-zone in Q4 2014.

!(

LEGEND

!(

CSM (Conceptual Site Model) well 1Key well 2Sentinel well 3Water supply well

1,1-DCE concentration contour(dashed = inferred)

MW-26D3 Well ID

7

!(

!(

!( Water level well

MW-36D326

Well ID and 1,1-DCE concentration 4(Q4 2014 concentration unless indicated otherwise)

Contingency well area

£Scale: 1" = 400'

Feet0 200 400

W Julie Dr

W Orion St

W Gemini Dr

7

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

1,1-DCE REMEDIAL ACTION PLANGROUNDWATER MONITORING NETWORK (D3-ZONE)

FIGURE

15

1,700 feet west toSRP well 20.6E-1.1S

Page 53: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

DECISION TREE FOR SRP WELL 21.5E-1.0S

CONTINGENCY ACTIONS AND REMEDY

Implement Base Level Monitoring (see P-RAP Section 4.2.1)

Yes

Yes

Yes

Yes

START*

Triggering Criterion Overview (see P-RAP Section 4.2.2)

Criterion

ScenarioSentinel wells A

SRP well

dischargeB SRP Well TrendC Groundwater Flow and

Solute Transport ModelD

1

Zone average >80% of

model-predicted peak

zone average or

>80% of model-

predicted peak

or

75% >model-

predicted slope

2

Zone average >125% of

model-predicted peak

zone average or

>100% of

model-

predicted peak

or

>5.6 µg/L in SRP

well discharge in

<4 years

3

Mass flux estimateE

indicates SRP well

discharge >6.3 µg/L or

>5.6 µg/L or

>5.6 µg/L in SRP

well discharge in

<2 years or

Revised model predicts >5.6

µg/L in SRP well discharge

in <4 years

4 >6.3 µg/L or

>7 µg/L in SRP

well discharge in

<2 years or

Revised model predicts >7

µg/L in SRP well discharge

in <4 years

Notes:

A = 1,1- DCE groundwater concentration in sentinel wells upgradient from SRP well 21.5E- 1.0S

B = Actual SRP well 21.5E- 1.0S 1,1- DCE discharge concentration

C = 1,1- DCE concentration trends in SRP well discharge based on a linear regression

D = Revised groundwater flow and solute transport model- predicted 1,1- DCE concentrations in SRP well discharge

E = Based on mass flux principle (see P- RAP Appendix A)

Triggered Contingency Actions Overview (see P-RAP Section 4.2.3)

Action

Level Actions

1▪ Level 1 monitoring program

▪ Determine if a Level 2 criterion is met

2

▪ Level 2 monitoring program

▪ Verify or update model accordingly

▪ Determine optimal locations for contingency extraction wells & secure

access agreements

▪ Determine if a Level 3 criterion is met

3

▪ Level 3 monitoring program

▪ Verify or update model accordingly

▪ Install contingency extraction well(s) upgradient from SRP well 21.5E-1.0S

▪ Determine optimal location for additional sentinel wells, secure access

agreements, and install wells, if appropriate

▪ Substantially complete groundwater treatment system design

▪ Determine if a Level 4 criterion is met

4

▪ Level 4 monitoring program

▪ Verify or update model to support design/optimization of groundwater

treatment system, as appropriate

▪ Complete design of groundwater treatement system

▪ Construct treatment system and commence operation

▪ Monitor effectiveness of the treatment system

▪ Determine if amendments of the FS report and remedial action plan are

required

Yes

Is a Scenario 1

criterion met?

(see P-RAP Section 4.2.2)

Is a Scenario 2

criterion met?

(see P-RAP Section 4.2.2)

Perform Action Level 2 work

(see P-RAP Section 4.2.3)

Is a Scenario 4

criterion met?

(see P-RAP Section 4.2.2)

Perform Level 4 work (see P-RAP Section 4.2.3)

Implement Contingency Remedy (see P-RAP Section 5)

No

No

No

Is a Scenario 3

criterion met?

(see P-RAP Section 4.2.2)

Perform Action Level 3 work

(see P-RAP Section 4.2.3)

Perform Action Level 1 work

(see P-RAP Section 4.2.3)

No

16

FORMER CAPITOL CASTINGS

TEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

Monitoring Program Overview (see P-RAP Table 1)

Level

CSM

verification

wells

Key

wells

Sentinel

wells

Contin-

gency

wells

SRP

well

Water-

levels Reporting

Base 1/4yrs 1/2yrs 2/yr# - 1/yr -- 1/yr 1/yr 1/yr

1 1/3yrs 1/yr 2/yr -- 2/yr 2/yr 2/yr

2 1/3yrs 1/yr 4/yr -- 2/yr 4/yr 2/yr

3 1/2yrs 2/yr 4/yr 4/yr 2/yr 4/yr 4/yr

4 1/2yrs 2/yr 4/yr 4/yr 4/yr 4/yr 4/yr

Notes:

1/4yrs = once every 4 years 1/yr = once a year

1/3yrs = once every 3 years 2/yr = twice a year

1/2yrs = once every 2 years 4/yr = four times a year# =D3- Zone sentinel wells monitored 2/yr during Base Level monitoring

*This figure is for illustrative purposes. See P-RAP Sections 4 and 5

for decision making mechanism.

SRP WELL 21.5E-1.0S

Page 54: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

DECISION TREE FOR SRP WELL 20.6E-1.1S

CONTINGENCY ACTIONS AND REMEDY

Triggering Criterion Overview (see P-RAP Section 4.2.2)

Criterion

ScenarioSentinel wells A SRP well

dischargeB SRP Well TrendC Groundwater Flow and

Solute Transport ModelD

1

Mass flux estimateE

indicates SRP well

discharge >3.2 µg/L or

>1 µg/L in SRP

well discharge

or

2

Mass flux estimateE

indicates SRP well

discharge >5.6 µg/L or

>4 µg/L in SRP

well discharge

or

>5.6 µg/L in SRP

well discharge in

<4 years

3Mass flux estimate

E

indicates SRP well

discharge >6.3 µg/L or

>5.6 µg/L or

>5.6 µg/L in SRP

well discharge in

<2 years or

Revised model predicts >5.6

µg/L in SRP well discharge

in <4 years

4 >6.3 µg/L or

>7 µg/L in SRP

well discharge in

<2 years or

Revised model predicts >7

µg/L in SRP well discharge

in <4 years

Notes:

A = Zone- averaged 1,1- DCE groundwater concentration in sentinel wells upgradient from SRP well 20.6E- 1.1S

B = SRP well 20.6E- 1.1S 1,1- DCE discharge concentration

C = 1,1- DCE concentration trends in SRP well discharge based on a linear regression

D = Revised groundwater flow and solute transport model- predicted 1,1- DCE concentrations in SRP well discharge

E = Based on mass flux principle (see P- RAP Appendix A)

Monitoring Program Overview (see P-RAP Table 1)

Level

CSM

verification

wells

Key

wells

Sentinel

wells

Contin-

gency

wells

SRP

well

Water-

levels Reporting

Base 1/4yrs 1/2yrs 2/yr# - 1/yr -- 1/yr 1/yr 1/yr

1 1/3yrs 1/yr 2/yr -- 2/yr 2/yr 2/yr

2 1/3yrs 1/yr 4/yr -- 2/yr 4/yr 2/yr

3 1/2yrs 2/yr 4/yr 4/yr 2/yr 4/yr 4/yr

4 1/2yrs 2/yr 4/yr 4/yr 4/yr 4/yr 4/yr

Notes:

1/4yrs = once every 4 years 1/yr = once a year

1/3yrs = once every 3 years 2/yr = twice a year

1/2yrs = once every 2 years 4/yr = four times a year# = D3- Zone sentinel wells monitored 2/yr during Base Level monitoring

Triggered Contingency Actions Overview (see P-RAP Section 4.2.3)

Action

Level Actions

1▪ Level 1 monitoring program

▪ Determine if a Level 2 criterion is met

2

▪ Level 2 monitoring program

▪ Verify or update model, if appropriate

▪ Determine optimal locations for sentinel & contingency extraction wells &

secure access agreements

▪ Install additional sentinel well(s) upgradient from SRP well 20.6E-1.1S

▪ Determine if a Level 3 criterion is met

3

▪ Level 3 monitoring program

▪ Update model

▪ Install contingency extraction wells upgradient from SRP well 20.6E-1.1S

▪ Determine optimal location for additional sentinel wells, secure access

agreements, and install wells, if appropriate

▪ Substantially complete groundwater treatment system design

▪ Determine if a Level 4 criterion is met

4

▪ Level 4 monitoring program

▪ Verify or update model to support design/optimization of groundwater

treatment system, as appropriate

▪ Complete design of groundwater treatement system

▪ Construct treatment system and commence operation

▪ Monitor effectiveness of the treatment system

▪ Determine if amendments of the FS report and remedial action plan are

required

17

FORMER CAPITOL CASTINGS

TEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

*This figure is for illustrative purposes. See P-RAP Sections 4 and 5

for decision making mechanism.

Implement Base Level Monitoring (see P-RAP Section 4.2.1)

Yes

Yes

Yes

Yes

START*

Yes

Is a Scenario 1

criterion met?

(see P-RAP Section 4.2.2)

Is a Scenario 2

criterion met?

(see P-RAP Section 4.2.2)

Perform Action Level 2 work

(see P-RAP Section 4.2.3)

Is a Scenario 4

criterion met?

(see P-RAP Section 4.2.2)

Perform Level 4 work (see P-RAP Section 4.2.3)

Implement Contingency Remedy (see P-RAP Section 5)

No

No

No

Is a Scenario 3

criterion met?

(see P-RAP Section 4.2.2)

Perform Action Level 3 work

(see P-RAP Section 4.2.3)

Perform Action Level 1 work

(see P-RAP Section 4.2.3)

No

SRP WELL 20.6E-1.1S

Page 55: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

FIGURE

18

FORMER CAPITOL CASTINGS FACILITYTEMPE, ARIZONA

PROPOSED REMEDIAL ACTION PLAN

PREDICTED 1,1-DCE CONCENTRATIONS IN SRP WELL 21.5E-1.0S DISCHARGE AND THE SENTINEL WELL ZONE-

AVERAGED CONCENTRATIONS IN GROUNDWATER

Note: D2-Zone average1,1-DCE concentration based on MW-34D2, MW-36D2, and MW-33D2 D3-Zone average 1,1-DCE concentration based on MW-34D3, MW-36D3, and MW-33D3

0

1

2

3

4

5

6

7

0

10

20

30

40

50

60

70

2015 2025 2035 2045 2055 2065 2075 2085 2095 2105

SRP

Wel

l Dis

char

ge 1

,1-D

CE C

once

ntra

tion

(ug/

L)

Zone

-Ave

rage

d Se

ntin

el W

ell 1

,1-D

CE C

once

ntra

tion

(ug/

L)

Year

D2-ZoneD3-ZoneSRP Well 21.5E-1.0S

D3-Zone

D2-Zone SRP Well 21.5E-1.0S

Page 56: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

AZ000905

.3814.00001

CONTINGENCY REMEDY

EXTRACTION WELLS AND

TREATMENT SYSTEM

PROCESS AND FLOW DIAGRAM

K. BRANTINGHAM R. MONGRAIN B. BROCKMAN C. SHEPHERD

B. BROCKMAN

PROPOSED REMEDIAL ACTION PLAN

FORMER CAPITOL CASTINGS FACILITY

TEMPE, ARIZONA

19

2015

Page 57: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Appendix A

Mass Discharge Concentration Calculator

Page 58: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

1 of 5

Appendix A Mass Discharge Concentration Calculator

Former Capitol Castings Facility Tempe, Arizona

The mass discharge concentration calculator1 will be used to make conservative estimates of future 1,1-DCE concentrations in the discharge of SRP well 21.5E-1.0S into Western Canal and future 1,1-DCE concentrations in the discharge of SRP well 20.6E-1.1S into High Line Canal water. These estimates will be used as described in Section 4.2.3.

To determine the predicted concentration in the SRP well discharge, a mass discharge profile is defined. The mass discharge is equal to total mass flux integrated across the entire area of the well transect and given by the following formulas:

j

jjjjd AqCM

1

where

Md = mass discharge C = contaminant concentration qj = specific discharge Aj = flow area

qj can be calculated using:

jji iKq

where

K = hydraulic conductivity i = hydraulic gradient

An example transect calculation in relation to SRP 21.5E-1.0S is provided below. The calculation employs the most recent aquifer property data from the updated groundwater flow and solute transport model, including hydraulic conductivity and hydraulic gradient, and 1,1-DCE concentration data from the most recent groundwater sampling events at individual monitoring points along the transect.

The 1,1-DCE plume is measured in width along the main flow path towards the SRP well in the aquifer zone with highest nearby observed concentrations. The calculation applies a percentage multiplier to the plume distribution profile since the monitoring well transect is not perpendicular to the groundwater flow in relation to the SRP well. To be conservative, a peak concentration multiplier is factored in for the reported concentrations along the varied screened depths of the transect.

Once the mass discharge profile is determined, the total mass per day is totaled and averaged over the entire transect area. A percentage multiplier is assumed for the pumping frequency since the pump does not run

1 “Use and Measurement of Mass Flux and Mass Discharge,” Interstate Technology and Regulatory Council Integrated DNAPL Site Strategy Team, August 2010 (http://www.itrcweb.org/GuidanceDocuments/MASSFLUX1).

Page 59: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

2 of 5

continuously. The average mass discharge per day is used to estimate the average concentration in the discharge of the SRP well as follows:

t

dd Q

MC

where

Cd = average concentration of entire transect Qt = steady state flow from extraction well Sources of error in the calculation include hydraulic conductivity and concentration data. However, the calculator is conservative and will be calibrated as needed to match the latest groundwater monitoring results and pumping data, by adjusting input parameters and SRP well pumping characteristics over time. The calculation conservatively assumes that the 1,1-DCE arrives instantaneously to the well and there is no degradation of 1,1-DCE.

Example Calculation – SRP 21.5E-1.0S 1,1-DCE Mass Discharge Concentration

This example calculation walks through the transect methodology used to estimate the future 1,1-DCE mass in the discharge of SRP 21.5E-1.0S into Western Canal.

The picture below is representative of the monitoring well transect used in this calculation. From West to East and upgradient of the SRP well, monitoring wells MW-34, MW-36, and MW-33 screened across the D-, A-, D2-, A2-, D3-, and D4-Zones are used in the calculation.

To determine the mass discharge, the specific discharge is first calculated using:

jji iKq

where

K = hydraulic conductivity i = hydraulic gradient

Page 60: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

3 of 5

Data used for this calculation include the most recent aquifer property data from the updated groundwater flow and solute transport model, including hydraulic conductivity and hydraulic gradient, and 1,1-DCE concentration data from the Fourth Quarter 2014 groundwater sampling of the monitoring wells comprising the transect.

Next, the width profile of the current plume dimension is determined based on iso-contours from the most recent groundwater monitoring data. Currently, monitoring well MW-36D3 is allocated the higher percentage while monitoring wells MW-34 and MW-33 are given lower percentages of the total plume width. A factor of 60% is conservatively assigned to the primary flow path in line with monitoring well MW-36, with respect to the plume width, and 20% to the exterior transect monitoring wells (MW-34 and MW-33).

Using the width profiles above, areas are then calculated for each transect cell.

Specific Discharge (q) Profile (ft /day)West East

ZoneBottom Depth MW-34 MW-36 MW-33 Total

K (feet/day)

i (feet/feet)

D 140 0.09 0.09 0.09 0.270 15 0.006A 160 0.012 0.012 0.012 0.036 2 0.006D2 190 0.066 0.066 0.066 0.198 11 0.006A2 220 0.09 0.09 0.09 0.270 15 0.006D3 290 0.08 0.08 0.08 0.240 40 0.002D3b 330 0.08 0.08 0.08 0.240 40 0.002D4 400 0.03 0.03 0.03 0.090 15 0.002

Width Profile (feet )West East

ZoneBottom Depth MW-34 MW-36 MW-33 Total Width

Peak Transect

D 140 130 390 130 650 60%A 160 130 390 130 650 60%D2 190 130 390 130 650 60%A2 220 130 390 130 650 60%D3 290 130 390 130 650 60%D3b 330 130 390 130 650 60%D4 400 130 390 130 650 60%Width of each area determined from isocontoursPeak concentration area should be minimum of 60% of the total width

Area (A) Profile (feet 2)West East

ZoneBottom Depth MW-34 MW-36 MW-33 Total Area

D 140 5200 15600 5200 26,000A 160 2600 7800 2600 13,000D2 190 3900 11700 3900 19,500A2 220 3900 11700 3900 19,500D3 290 9100 27300 9100 45,500D3b 330 5200 15600 5200 26,000D4 400 9100 27300 9100 45,500

Page 61: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

4 of 5

Data from the latest monitoring event is then referenced to populate the concentration profile.

Where concentrations are unknown, a conservative concentration is assumed:

In the A2-Zone, the concentration will be set equal to the concentration in the D2-Zone In the D3b-Zone, the concentration will be set equal to the 1/10th of the D3-Zone, and In the D4-Zone, the concentration will be set equal to the 1/10th of the D4-Zone.

The mass discharge is then calculated for the individual cells based on the following equation:

j

jjjjd AqCM

1

where

Md = mass discharge C = contaminant concentration qj = specific discharge Aj = flow area j = unit area cell of transect

Finally, the average estimated concentration in the SRP extraction well is calculated as follows:

t

dd Q

MC

Concentration (C) Profile (ug/L)West East

ZoneBottom Depth MW-34 MW-36 MW-33 Total %

D 140 0 0 0 0 0%A 160 0 0 0 0 0%D2 190 0 0 0 0 0%A2 220 0 0 0 0 0%D3 290 1.5 26 0 28 90%D3b 330 0.15 2.6 0 3 9%D4 400 0.015 0.26 0 0 1%

Mass Disharge Profile (Md) (ug/day)West East

ZoneBottom Depth MW-34 MW-36 MW-33 Total Mass % Flux

D 140 0 0 0 0 0%A 160 0 0 0 0 0%D2 190 0 0 0 0 0%A2 220 0 0 0 0 0%D3 290 30,922 2,009,930 0 2,040,852 94%D3b 330 1,767 114,853 0 116,620 5%D4 400 116 7,537 0 7,653 0%

∙ ∙

Page 62: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

5 of 5

where

Cd = average concentration of entire transect Qt = steady state flow from extraction well Based on the referenced concentration profiles, plume dimensions, aquifer properties, and the average flow rate of the SRP well (481 gpm), the estimated 1,1-DCE concentration in the well’s discharge is 0.8 µg/L. For the same time period, the groundwater flow and solute transport model predicts a concentration of 0.13 g/L, indicating the mass discharge calculation is conservative.

Page 63: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Appendix B

Estimated Costs

Page 64: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Appendix BEstimated Remedial Action Plan Capital and Incremental Costs

Former Capitol Castings Tempe, AZ

G:\ENV\ENV\PROJ\900\905 Rio Tinto 2\07 Tech_Projects\_DCE\2014-08_PRAP\Deliverables\PRAP Rev 2\PRAP Report Tables 20160229.xlsx 1 of1

Proposed Remedial Action Plan (Base Level) CostsMonitoring Equipment Capital $15,000Annual Groundwater Sampling (Average 25 groundwater samples per year)

Labor and expenses $24,400Laboratory $3,200Permits, Well Repair, and Maintenance $23,000

Annual Groundwater Monitoring ReportingLabor and expenses $18,300

Miscellaneous/ Contingency $18,700Total Annual Cost $88,000

5 Years $440,00010 Years $880,000

Notes:Miscellaneous costs include: stakeholder engagement, project management, health and safety, and quality control.

Page 65: AR CAD ISazdeq.gov/environ/waste/cleanup/download/prap_former... · 2016-03-04 · AR CAD IS Infrastructure· Water· Environment· Buildings Via Email and Federal Express Joey Pace

Appendix BEstimated Contingency Remedial Action Plan Capital and Incremental Costs

Former Capitol Castings Tempe, AZ

G:\ENV\ENV\PROJ\900\905 Rio Tinto 2\07 Tech_Projects\_DCE\2014-08_PRAP\Deliverables\PRAP Rev 2\PRAP Report Tables 20160229.xlsx 1 of1

Contingency Remedial Action Plan (Level 4) CostsContingency Treatment System Installation

FS/PRAP/Model subtotal $125,500System Design/ OM&M Plan $60,300Permitting/Surveying/Utility Clearance $57,000Extraction Well Installation (2 wells to 200 feet and 2 wells to 280 feet) $307,000Treatment System Equipment $391,100Treatment System Installation $536,200System Startup and Shakedown $80,000

Miscellaneous/ Contingency $482,700$2,039,800

Annual CostsQuarterly Groundwater Sampling (Average 83 groundwater samples per year)

Labor and expenses $187,500Laboratory $10,700Permits, Well Repair, and Maintenance $26,000

Groundwater Monitoring Report (Quarterly)Labor and expenses $52,800

Pump and Treat System Operation, Maintenance, and Disposal $354,000

Syststem Evaluation and ReportingLabor and expenses $11,600

Miscellaneous/ Contingency $91,400Total Annual Cost $745,600

5 Years $3,728,00010 Years $7,456,000

Notes:Miscellaneous costs include: stakeholder engagement, project management, health and safety, and quality control.

Total Capital Costs, Treatment System Installation