assembly & installation instructions: ciglio2 under...
TRANSCRIPT
No tools are required for installing to metal cabinets. #2 Phillips head screwdriver or drill/driver and a 3/32" drill bit is used for installing to wood cabinets.
1 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
A Light Fixture Qty: 1 D Transformer & Power Cord
Qty: 1 E Master Switch
F Jumper Cables 12" & 24"
Assembly & Installation Instructions:Ciglio2 Under-Cabinet Light - FixtureCIG2-UCL16-S; CIG2-UCL28-S; CIG2-UCL38-S
Parts Included Required, sold separately Optional, sold separately
Tools Required
B Universal Mounting Kit Qty: Varies depending on configuration
C Power Jumper Cable Qty: 1
Determine which configuration you have purchased and proceed to the page number for your specific installation steps.✓Single Fixture
Page 2
Single Fixture with Master Switch
Page 4
Multiple Fixtures (daisy-chain)
Page 6
Multiple Fixtures (daisy-chain) with
Master Switch Page 8
16" Fixture shown
One required per configuration Differs per configuration
2 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
Set Light Fixture to “Parent”Make sure the micro-switch located on the center backside of the fixture is switched towards "Parent" (to the left.)
Instructions for Single Fixture
Mount to CabinetDetermine if light will be mounted to a metal or wood cabinet and follow the appropriate step below:
Metal cabinet mounts: Place Magnetic Mounts (B) onto back of Light Fixture (A).
Attach Light Fixture to metal under-cabinet. Magnets will hold the fixture in place.
Wood cabinet mounts: Note: You will need a 3/32" drill bit and #2 Phillips screwdriver to complete this step.
Determine where you want to mount your light and draw a straight line on the underside of the cabinet to indicate the center along the length of the light.
Place Mount along center line and mark the hole locations. Drill pilot-holes at the marked locations.
Tip: Attaching the Mounts closer to the center of the fixture will allow additional side to side adjustment.
Attach the Wood Mounts (B) with screws provided in the Mounting Kit at drilled locations.
Attach Light Switch (A) onto mounts. Magnets will hold the fixture in place.
Under-cabinet
Draw line
Mark & Drill
8"–15" depending on size
Parent Child
Parent Child
1
2
A
A
a
a
a
b
b
c
d
d
a
b
b
c
Lift light onto mounts
Place lamp under cabinet
3 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
Power On & DimmingTo turn the power on/off, tap the indicator light once to turn it on and once again to turn it off.
To adjust the brightness, touch your finger on the indicator light and keep in place for few seconds. Remove finger when you've achieved desired brightness.
To direct light, swivel by grabbing both ends of the Fixture (so magnets do not detach) and pivot on mounts back and forth.
Attach Fixture to the Transformer & Plug InInsert Power Jumper Cable (C) into Fixture (A)
Plug Transformer Cord (D) into Power Jumper Cable (C).
Plug Power Cord into Transformer.
Plug the Power Cord into a wall outlet.
4
3 A
D
C
a
ab
bcd
d
c
Power Cord included with Transformer (D)
Tap the indicator light to turn on/off
To swivel, grab at both ends
4 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
Single Fixture with Master Switch
Set Light Fixture to “Child”Make sure the micro-switch located on the center backside of the fixture is switched towards "Child" (to the left.)
Attach Master Switch to First FixtureInsert the In-line Coupler from the Universal Mounting Kit (B) into the receptacle at the end of the Fixture (A)
Insert the Master Switch (E) onto the connector.
Note: The Master Switch can be located either side of the Fixture.
Mount to CabinetDetermine if light will be mounted to a metal or wood cabinet and follow the appropriate steps below:
Metal cabinet mounts: Place Magnetic Mounts (B) onto back of Light Fixture (A).
Attach Light Fixture to metal under-cabinet. Magnets will hold the fixture in place.
Wood cabinet mounts: Note: You will need a 3/32" drill bit and #2 Phillips screwdriver to complete this step.
Determine where you want to mount your light and draw a straight line on the underside of the cabinet to indicate the center along the length of the light.
Place Mount along center line and mark the hole locations. Drill pilot-holes at the marked locations.
Tip: Attaching the Mounts closer to the center of the fixture will allow additional side to side adjustment.
Attach the Wood Mounts (B) with screws provided in the Mounting Kit at drilled locations.
Attach Light Switch (A) onto mounts. Magnets will hold the fixture in place.
Parent Child
Parent Child
Under-cabinet
Draw line
Mark & Drill
8"–15" depending on size
1
3 a
a
b
b
A
B
E
2
A
A
a
a
a
b
b
c
d
a
b
b
c
d
Lift light onto mounts
Place lamp under cabinet
5 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
Attach Fixture with Master Switch to the Transformer & Plug InInsert Power Jumper Cable (C) into Master Switch (E).
Plug Transformer Cord (D) into Power Jumper Cable (C).
Plug Power Cord into Transformer.
Plug the Power Cord into a wall outlet.
Power On & DimmingTo turn the power on, simply touch the Touch Strip. To Turn off, touch the smallest dot on the Touch Strip.
To dim the light, move your finger on the Touch Strip to achieve the desired brightness.
To direct light, swivel by grabbing both ends of the Fixture (so magnets do not detach) and pivot on mounts back and forth.
Note: Consult the Master Switch Instruction for detailed information on mounting, dimming and occupancy sensing.
Dimming
4 A
E
D
C
a
a
b
b
cd
d
c
Power Cord included with Transformer (D)
Touch Strip
5a a
b b
6 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
Multiple Fixtures (Daisy-Chain)
Set One Light Fixture to “Parent” the Others to "Child"Choose one of your multiple fixtures to be the "Parent" that will control the other "Child" lights. Any Fixture can be the "Parent." Make sure the micro-switch located on the center backside of the fixture is switched towards "Parent" (to the left.)
Make sure the micro-switch is switched towards "Child" (to the right) on all other Fixtures.
Mount to CabinetDetermine if light will be mounted to a metal or wood cabinet and follow the appropriate steps below:
Metal cabinet mounts: Place Magnetic Mounts (B) onto back of Light Fixture (A).
Attach Light Fixture to metal under-cabinet. Magnets will hold the fixture in place.
Wood cabinet mounts: Note: You will need a 3/32" drill bit and #2 Phillips screwdriver to complete this step.
Determine where you want to mount your light and draw a straight line on the underside of the cabinet to indicate the center along the length of the light.
Place Mount along center line and mark the hole locations. Drill pilot-holes at the marked locations.
Tip: Attaching the Mounts closer to the center of the fixture will allow additional side to side adjustment.
Attach the Wood Mounts (B) with screws provided in the Mounting Kit at drilled locations.
Attach Light Switch (A) onto mounts. Magnets will hold the fixture in place.
Parent Child
Parent Child
Parent Child
Parent Child
Under-cabinet
Draw line
Mark & Drill
8"–15" depending on size
1
2
A
A
a
a
a
b
b
c
d
d
a
b
b
c
Lift light onto mounts
Place lamp under cabinet
7 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
Attach Fixture to the Transformer & Plug InConnect Power Jumper Cable (C) to either end of your daisy-chain.
Plug Transformer Cord (D) into Power Jumper Cable (C).
Plug Power cord into Transformer (D).
Plug the Power Cord into a wall outlet.
Connect All Fixtures With JumpersConnect all Daisy Chain Light Fixtures(A) with appropriate length Jumpers (F) or In-line Coupler (B).
Power On & DimmingTo turn the power on/off, tap the indicator light on the Parent fixture, once to turn it on and once again to turn it off.
To adjust the brightness, touch your finger on the indicator light and keep in place for few seconds. Remove finger when you've achieved desired brightness.
To direct light, swivel by grabbing both ends of the Fixture (so magnets do not detach) and pivot on mounts back and forth.
4
3 A
A
FB
D
C
a
a
b
b
cd
d
c
Power Cord included with Transformer (D)
or or
5Tap the indicator light to turn on/off
To swivel, grab at both ends
8 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
Multiple Fixtures (Daisy-Chain) With Master Switch
Set All Light Fixtures to “Child”Make sure the micro-switch located on the center backside of all fixtures are switched towards "Child" (to the right.)
Mount to CabinetDetermine if light will be mounted to a metal or wood cabinet and follow the appropriate steps below:
Metal cabinet mounts: Place Magnetic Mounts (B) onto back of Light Fixture (A).
Attach Light Fixture to metal under-cabinet. Magnets will hold the fixture in place.
Wood cabinet mounts: Note: You will need a 3/32" drill bit and #2 Phillips screwdriver to complete this step.
Determine where you want to mount your light and draw a straight line on the underside of the cabinet to indicate the center along the length of the light.
Place Mount along center line and mark the hole locations. Drill pilot-holes at the marked locations.
Tip: Attaching the Mounts closer to the center of the fixture will allow additional side to side adjustment.
Attach the Wood Mounts (B) with screws provided in the Mounting Kit at drilled locations.
Attach Light Switch (A) onto mounts. Magnets will hold the fixture in place.
Parent Child
Parent Child
Under-cabinet
Draw line
Mark & Drill
8"–15" depending on size
1
2
A
A
a
a
a
b
b
c
d
d
a
b
b
c
Lift light onto mounts
Place lamp under cabinet
9 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
Attach Master Switch to First FixtureInsert the In-line Coupler from the Universal Mounting Kit (B) into the receptacle at the end of the Fixture (A)
Insert the Master Switch (E) onto the connector.
Note: The Master Switch can be located anywhere on the Daisy Chain, as long as all Fixtures are set to "Child" and connected with Jumpers or the In-line Coupler.
Connect All Fixtures With JumpersConnect all Daisy Chain Light Fixtures(A) with appropriate length Jumpers (F) or In-line Coupler (B).
4 a
ab
b
A
B
E
3 A
A
F
or or
B
10 of 10 Workrite Ergonomics | 800.959.9675 www.workriteergo.com
#1500331 Rev C
Power On & DimmingTo turn the power on, simply touch the Touch Strip. The entire daisy-chain will illuminate. To Turn off, touch the smallest dot on the Touch Strip.
To dim the light, move your finger on the Touch Strip to achieve the desired brightness.
Note: Consult the Master Switch Instruction for detailed information on mounting, dimming and occupancy sensing.
To direct light, swivel by grabbing both ends of the Fixture (so magnets do not detach) and pivot on mounts back and forth.
Attach Fixture with Master Switch to the Transformer & Plug InInsert Power Jumper Cable (C) into either side of the daisy-chain (it does not need to be installed into the Master Switch).
Plug Transformer Cord (D) into Power Jumper Cable (C).
Plug Power Cord into Transformer.
Plug the Power Cord into a wall outlet.
Replacement parts
Universal Mounting Kit .........................................................CIG2-MT-ICPower Adapter .......................................................................CIG2-CABLE-PWR48 W Transformer ..................................................................TR-65242700-A-RF5.5Master Switch ........................................................................CIG2-MS-OCC-SCiglio2, 12” Molex Jumper Cable ..........................................CIG2-CABLE-12-BCiglio2, 24” Molex Jumper Cable ..........................................CIG2-CABLE-24-B
Warranty: Ciglio2 fixture, 5 years. Ciglio2 transformer, 3 year.
Dimming
Touch Strip
To swivel, grab at both ends
6a a
bb
5 A
E
D
C
a
a
b
b
cd
d
c
Power Cord included with Transformer (D)
✓