associaÇÃo brasileira de mecÂnica de...
TRANSCRIPT
![Page 1: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/1.jpg)
ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE SOLOS - ABMS
PALESTRA MILTON VARGAS
2017
![Page 2: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/2.jpg)
QUEBRANDO PARADIGMAS NA
ENGENHARIA DE FUNDAÇÕES
Luciano Décourt
Engenheiro Civil – Professor Universitário
![Page 3: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/3.jpg)
COMMON PROCEDURES FOR FOUNDATION SETTLEMENT ANALYSIS -
ARE THEY ADEQUATE ?
POULOS, H.G.
8TH AUSTRALIAN – NEW ZEALAND CONFERENCE ON GEOMECHANICS
1999
![Page 4: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/4.jpg)
“It is axiomatic that an essential ingredientfor successful settlement prediction is theselection of appropriate geotechnicalparameters. It is the author’s experiencethat settlement predictions are far moresensitive to the geotechnical parametersand site characterization than to themethod of analysis (e.g. Poulos, 1989).”
![Page 5: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/5.jpg)
PARTE 1
CONHECENDO O SOLO
SPT – SPT-T
PARTE 2
FUNDAÇÕESDIRETAS
PARTE 3
FUNDAÇÕES PROFUNDAS
PARTE 4
EVENTOS DE PREVISÃOA HORA DA VERDADE
“CONTRA FACTUM NON VALET
ARGUMENTUM”
![Page 6: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/6.jpg)
SPT – SPT-T
![Page 7: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/7.jpg)
THE DYNAMIC PENETRATION TEST A STANDARD THAT IS NOT STANDARDIZED
IRELAND, H. O., MORETO, O. VARGAS, M.
GÉOTECHNIQUE, VOLUME 20, ISSUE 2
LONDON, U.K., 1970
![Page 8: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/8.jpg)
UM CASO ONDE O SPT FALHOU NA PREVISÃO DO
COMPRIMENTO DE ESTACAS
DÉCOURT, L.
VII COBRAMSEF
PORTO ALEGRE, BRASIL, 1986
![Page 9: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/9.jpg)
STANDARD PENETRATION TEST (SPT) INTERNATIONAL REFERENCE TEST
PROCEDURE
DÉCOURT, L.; MUROMACHI, T.; NIXON, I.K.; SCHMERTMANN, J.H.;
THORBURN, S.; ZOLKOV, E.
ISOPT I ORLANDO, USA, 1988
![Page 10: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/10.jpg)
THE STANDARD PENETRATION TESTSTATE OF THE ART REPORT
DÉCOURT, L.
XII ICSMFE/CIMSTFRIO DE JANEIRO, BRAZIL, 1989
![Page 11: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/11.jpg)
![Page 12: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/12.jpg)
![Page 13: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/13.jpg)
“THE MECHANICAL AGING OF SOILS” 25th Terzaghi Lecture....1991
John H. Schmertmann
L. Décourt (1989) observed that the Bazaraa (1967)
correlations, based on field data, if adjusted by an aging factor
of 0.4–0.6 would approximatelly match the SPT vs. relative
density correlations previously obtained by Gibbs and Holtz
(1957) and Marcuson and Bieganouski (1977). The writer
believes that the above aging explanation helps greatly to
explain a big mistery – namely why the Bazaraa correlations did
not fit well with the others.
![Page 14: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/14.jpg)
BRAZILIAN EXPERIENCE ON SPT
DÉCOURT, L.; BELICANTA, A.; QUARESMA FILHO, A.R.
XII ICSMFE SUPLEMENTARY CONTRIBUTIONS BY
ABMS
RIO DE JANEIRO, BRAZIL, 1989
![Page 15: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/15.jpg)
THE SPT-T AN IMPROVED SPT
DÉCOURT, L. QUARESMA FILHO, A.R.
SEFE II
SÃO PAULO, BRAZIL, 1991
![Page 16: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/16.jpg)
Em 1991, postulei que, para solos fora daBacia Sedimentar Terceária de São Paulo,BSTSP, as correlações estabelecidas para essaregião poderiam ser utilizadas, com sucesso,em outros locais, desde que os valores de Neq
viessem a ser utilizados no lugar dos valoresmedidos de SPT.
Neq foi definido como sendo o valor do torque,T, medido em kgf.m dividido por 1,2.
![Page 17: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/17.jpg)
PRACTICAL APPLICATIONS OF THE STANDARD PENETRATION TEST COMPLEMENTED BY TORQUE
MEASUREMENTS
DÉCOURT, L.; QUARESMA FILHO, A.R.
XIII ICSMFE
NEW DELHI, INDIA , 1994
![Page 18: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/18.jpg)
![Page 19: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/19.jpg)
A MORE RATIONAL UTILIZATION OF SOME OLD IN SITU TESTS
DÉCOURT, L.
FIRST INTERNATIONAL CONFERENCE ON SITE CHARACTERIZATION – ISC
ATLANTA, U.S.A., 1998
![Page 20: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/20.jpg)
![Page 21: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/21.jpg)
Ei≈45-50% Ei≈72%
Correção dos valores medidos de NSPT, em Correção dos valores medidos de NSPT, em
areias finas, abaixo do nível d’água (Ei≈45-50%) areias finas, abaixo do nível d’água (Ei≈72%)
![Page 22: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/22.jpg)
SPT, SPT-T. A PRÁTICA BRASILEIRA: VANTAGENS, LIMITAÇÕES E CRÍTICAS
DÉCOURT, L.
ABMS, NÚCLEO REGIONALDE SÃO PAULO
SÃO PAULO, BRASIL, 2002
![Page 23: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/23.jpg)
I AREIA FOFA N60 = 3,0 + 0,6z
II AREIA MEDIANAMENTE COMPACTA N60 = 8,4 + 1,2z
III AREIA COMPACTA N60 = 21,6 + 1,8z
IV AREIA MUITO COMPACTA N60 = 33 + 3,0z
LEGENDAI AREIA FOFA N60 = 3,0 + 0,6z
II AREIA MEDIANAMENTE COMPACTA N60 = 8,4 + 1,2z
III AREIA COMPACTA N60 = 21,6 + 1,8z
IV AREIA MUITO COMPACTA N60 = 33 + 3,0z
LEGENDA
![Page 24: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/24.jpg)
PARA ARGILAS RIJAS E DURAS DA BSTSP
Cu (kPa) = 12,5 N72
Cu (kPa) = 10,42 T
![Page 25: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/25.jpg)
Valores de NSPT; Torque, T; Cu (Vane Test) e Cu, aplicadas para uma argila quaternária, muito mole, do Guarujá.
![Page 26: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/26.jpg)
![Page 27: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/27.jpg)
ÍNDICE de BOSIOPara solos muito duros/ muito densos
(N60 ≥ 60)IB = 22 / P50 - P30
P50.......Penetração do amostradorpara 50 golpes(cm)
P30.......Penetração do amostradorpara 30 golpes(cm)
![Page 28: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/28.jpg)
![Page 29: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/29.jpg)
CONCLUSÃO
SPT-T+ IBBOM PARA SOLOS NÃO LATERÍTICOS
S-SPT-T + IB
BOM PARA TODOS OS SOLOS
![Page 30: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/30.jpg)
O CONCEITO DE N EQUIVALENTE, Neq, NA PRÁTICA DA ENGENHARIA.
AINDA UM POSTULADO OU JÁ UMA REALIDADE COMPROVADA?
DÉCOURT, L.
XII COBRAMSEG
SÃO PAULO, BRASIL, 2002
![Page 31: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/31.jpg)
FUNDAÇÕES DIRETAS
![Page 32: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/32.jpg)
BEARING CAPACITY OF LONG FOOTINGS, qu
TERZAGHI
qu = cNc + qNq + 1/2γBNγ
![Page 33: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/33.jpg)
ALGUMAS OPINIÕES RELATIVAS
À VALIDADE DAS TEORIAS
DE CAPACIDADE DE CARGA
![Page 34: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/34.jpg)
BRIAUD AND JEANJEAN (1994)
“If is a constant and independent of B,then Ng, cannot be a constant and must carry ascale effect in 1/B.This major shortcoming plus the difficulty inobtaining an accurate value of the needed soilparameter Ø and the documented pooraccuracy of this method (Amar et al. 1984) leadto the recommendation that:
- The use of this equation should bediscontinued”.
![Page 35: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/35.jpg)
DÉCOURT (1999)
“What has been done in the past 60 yearswas adequate, but, only for that time.On the threshold of the 21st century,however, it is mandatory that we clear ourminds of some concepts that helped for awhile, but now prevent any furtherdevelopment of the art of designingfoundations.It is being proposed that design approaches
![Page 36: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/36.jpg)
based on these concepts be abandoned.Emphasis has to be given to settlements.Foundation designs in the 21st century,other than for displacement piles, shouldrely exclusively on settlement computations,leaving the ghosts of bearing capacitytheories and failures to the past, dulyexorcised and buried, to show up nevermore”.
![Page 37: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/37.jpg)
FELLENIUS, B.H. (1999)
“It is amazing that the arbitrary nature of thecalculated N-factors has not long ago sent theformula to the place where it belongs – themuseum of old paradigms whose time haspassed. However, the bearing capacity is sowell entrenched that stating that it is wrongand should not be used would seem to borderor committing heresy. When I now say so,should I fear being burned at the stake, or isthe practice ready to accept new views ?”
![Page 38: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/38.jpg)
POULOS, H.G. (2010)
“Unfortunately, there is now considerableevidence that demonstrates that this theoreticalconclusion is not confirmed in practice.Décourt (2008) has re-plotted data from testson footings of various sizes and found that,when normalized with respect tosettlement/diameter (s/b), the load-settlementcurves are unique and not dependent on thefooting size nor on the relative density.
![Page 39: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/39.jpg)
Similar conclusions have been reachedfrom recent centrifuge test carried out onmodel footings by Gavin et al (2009).
Akbas and Kulhawy (2009) have arrived toconclusions similar to those of Décourtand Gavin et al”.
![Page 40: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/40.jpg)
![Page 41: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/41.jpg)
Basics of Foundation Design
January 2017
Bengt H. Fellenius Dr. Tech., P. Eng.
![Page 42: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/42.jpg)
“However, tests on full-size footings have shown that bearing capacity in terms of an ultimate resistance at which failure occurs, does not exist. It has been shown conclusively that the theoretical treatment of bearing capacity provides an incorrect picture of actual response of footings to load. The correct modeling of footing response is a settlement analysis (Chapter 3).…
![Page 43: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/43.jpg)
…
That the subject treatment in Section 6.2 through 6.5 is at all presented here is primarily in order to serve as a piece of historical geotechnics. The practicing design engineer is strongly advised against actually applying the formulas and relations presented. The details behind this recommendation are presented in Section 6.10. Sections 6.2 through 6.9 are only provided to present the historical or conventional approach. I do not suggest that the approach would in any way be correct.”
![Page 44: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/44.jpg)
“THE INDISPUTABLE FACT IS THAT BEARING CAPACITY OF A REAL-SIZE FOOTING DOES NOT
REALLY EXIST.”
O FATO INDISCUTÍVEL É QUE A CAPACIDADEDE CARGA DE SAPATAS DE TAMANHO REAL
REALMENTE NÃO EXISTE.
“WHEN THE BASIC CONCEPT FOR A RESPONSE IS WRONG, SIMPLY, ANY INTERPRETATION OF THE
RESULTS BASED ON THAT CONCEPT IS ALSO WRONG!”
QUANDO O CONCEITO BÁSICO ESTÁ ERRADO, SIMPLESMENTE, QUALQUER INTERPRETAÇÃO DE
RESULTADOS BASEADA NESSE CONCEITO TAMBÉM ESTÁ ERRADA!
![Page 45: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/45.jpg)
FUNDAÇÕES E INTERAÇÃO
SOLO- ESTRUTURA
DÉCOURT, L.
X COBRAMSEF
RELATO GERAL
FOZ DO IGUAÇU, BRASIL , 1994
![Page 46: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/46.jpg)
CURVA BÁSICA
log (q/qr) = 0,426 + 0,426 log (s/Beq)
![Page 47: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/47.jpg)
![Page 48: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/48.jpg)
THE BEHAVIOR OF A BUILDING WITHSHALLOW FOUNDATIONS ON A STIFF
LATERITIC CLAY
DÉCOURT, L.
ASCE, GSP 40VERTICAL AND HORIZONTAL DEFORMATIONS
OF FOUNDATIONS AND ENBANKMENTS
TEXAS, U.S.A., 1994
![Page 49: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/49.jpg)
PREDICTION OF LOAD SETTLEMENT RELATIONSHIPS FOR FOUNDATIONS ON
THE BASIS OF THE SPT-T
DÉCOURT, L.
CYCLE OF INTERNATIONAL CONFERENCES LEONARDO ZEEVAERT
MEXICO, 1995
![Page 50: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/50.jpg)
ASSESSMENT OF THE REFERENCE STRESS, qr
ON BASIS OF NSPT , Neq AND T, FORCOMMON SOILS
Soil type I………………sands
Soils type II…………….intermediate soils
Soils type III……….…..saturated clays (Øu= zero)
![Page 51: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/51.jpg)
SOLO qr (kPa) qr (kgf/cm2) qr (kPa) qr (kgf/cm2)
I 95N60/95T 0,95N60/0,95T 114N72/114Neq 1,14 N72/1,14Neq
II 80N60/80T 0,80N60/0,80T 96N72/9,6Neq 0,96 N72/0,96Neq
III 65N60/65T 0,65N60/0,65T 78N72/7,8Neq 0,78 N72/0,78Neq
![Page 52: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/52.jpg)
ASSESSMENT OF THE REFERENCE STRESS,qr ON BASIS OF NSPT, Neq AND T, FOR LATERITIC SOILS
For the practicing foundation engineer, whatmatters is that lateritic soils (LS) are much stifferthan non lateritic soils (NLS).The extraordinary stiffness characteristics oflateritic clays have been ignored by foundationengineers. Décourt (1994) showed, for the firsttime, that lateritic clays are much stiffer thannon lateritic clays with equal SPT values.
![Page 53: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/53.jpg)
O procedimento proposto para a avaliação de qr
com base no NSPT não é aplicável para todos ossolos. Para solos saprolíticos, o método dáresultados confiáveis, desde que se use valoresde Neq em lugar dos valores de NSPT.
Entretanto, para solos lateríticos, o fator demajoração αL, que leva em conta os benefícios dalaterização, tem que ser usado.
Com base em experiência anterior, sugere-sevalores de αL entre 2.0 e 3.0.
![Page 54: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/54.jpg)
Um outro importantíssimo parâmetro a serconsiderado é o Coeficiente deCompressibilidade Intrínseca, “C”, Décourt(1999). Para a grande maioria dos solos, o valorC= 0,42, conduz a previsões adequadas.Para solos lateríticos (LS), os valores de “C”estão na faixa de 0,21 a 0,45.
Valores mais precisos podem ser obtidossomente através de provas de carga. Naausência destes ensaios, sugere-se, para soloslateríticos, valores entre 0,28 e 0,42.
![Page 55: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/55.jpg)
Valores de recalque para fundações rasas, com B=3,0m, em função de q/qr e “C”
![Page 56: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/56.jpg)
BEHAVIOR OF FOUNDATIONS UNDER WORKING LOAD CONDITIONS
DÉCOURT, L.
XI PAMCSMGE
FOZ DE IGUAÇU, BRAZIL, 1999
![Page 57: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/57.jpg)
DÉCOURT PROPOSALS (1999)
log (q/qr) = C + C log (s/Beq) or
log (q/qr) = C (1 + log s/Beq)
“C” is approximately constant for a given type ofmineral. For quartz sands, either sedimentaryor residual, the values of “C” are in the range0.40 ± 15% and for calcareous sands in therange 0.70 ± 15%..
![Page 58: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/58.jpg)
FELLENIUS PROPOSALS (1999)
q/qr = (s/sr)e
The reference parameters qr and sr are the same used in Décourt’s method.
The Fellenius “e” value is identical to the Décourt“C” value. The range of the proposed “e” valuesvaries between 0.5 and 0.9, which isapproximately, the same range proposed byDécourt (1999), for calcareous sands.
This is by no means surprising because Fellenius´sanalysis was based on load tests carried out incalcareous sands.
![Page 59: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/59.jpg)
FUNDAMENTOS DO
MÉTODO PROPOSTO
ALGUMAS EVIDÊNCIAS
DE SUA CONFIABILIDADE
![Page 60: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/60.jpg)
VESIC (1963)
Vesic (1963) and other authors suggested that
for very dense sands, the stress-settlement
curve displays a peak and next, stresses start
declining with the displacements.
![Page 61: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/61.jpg)
Curva tensão x recalque para uma
sapata em uma areia muito densa, RJ,
Brasil.
Curva tensão x recalque para uma
sapata em uma rocha filitica branda,
SP, Brasil.
Os slides seguintes mostram resultados de provas de cargaexecutadas em uma areia muito densa e em uma rocha branda,não evidenciando o comportamento sugerido por Vesic
![Page 62: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/62.jpg)
UNICIDADE DA CURVA NORMALIZADA CARGA (TENSÃO) - RECALQUE
Em 1999, afirmei que a curva tensão-recalque,normalizada, era única, não dependendo dadensidade da areia, do tamanho da sapata e desua profundidade.As tensões foram normalizadas pela tensão dereferência, qr, que é a tensão que corresponde aum recalque de 10% do lado de uma sapataquadrada e o recalque, pela largura da sapata(ou diâmetro da estaca).Todas as análises procedidas desde então,confirmaram essa assertiva.
![Page 63: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/63.jpg)
Curvas tensão x recalque , Texas, U.S.A. Curvas normalizadas tensão x recalque, Texas, U.S.A.
Curvas tensão x recalque para sapatas em uma areia
laterítica em dieferentes profundidades, Bauru, S.P.,
Brasil
Curvas normalizadas tensão x recalque, Bauru, S.P.,
Brazil.
![Page 64: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/64.jpg)
O MÉTODO RDZ
Contrariamente ao procedimento usual paradimensionamento de fundações que objetiva aobtenção de uma tensão admissível, o MétodoRDZ objetiva a obtenção de recalques diferenciaiszero, entre todas as sapatas. Como consequênciaóbvia, as tensões a serem aplicadas ao solo pelassapatas terão que ser diferentes.
É muito importante salientar que os “imputs” aserem utilizados são aqueles fornecidos porensaios de rotina, SPT, SPT-T e CPT.
![Page 65: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/65.jpg)
SAPATAS ESTAQUEADAS (ESTACAS-T)O método Décourt é usado não apenas para fundaçõesdiretas. Ele também é usado para projetos de sapatasestaqueadas (Estacas–T).
Tipicamente, uma estaca (ou mais) é colocada sob asapata no centro da coluna e sua capacidade de carga écalculada. Para a estaca, sua capacidade é admitida comosendo totalmente desenvolvida para o deslocamentos doseu topo, de 15mm.
O procedimento proposto é o de simplesmente subtrairda carga nominal da coluna o valor de 80% docorrespondente à capacidade calculadada da estaca eprosseguir com o projeto, como se tratasse de umasimples sapata, com essa carga reduzida.
![Page 66: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/66.jpg)
O método de rigidez parasapata estaqueada
PROVA DE CARGA EM SAPATA ESTAQUEADA
Curva carga x recalque para sapata estaqueada
![Page 67: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/67.jpg)
PREDICTED AND MEASURED BEHAVIOR OF A TALL BUILDING IN A LATERITIC CLAY
DÉCOURT, L.; GROTTA JR., C.; PENNA, A. S.; CAMPOS, G. C.
5th INTERNATIONAL CONFERENCE ON SITE CHARACTERIZATION – ISC 5
QUEENSLAND, AUSTRALIA, 2016
![Page 68: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/68.jpg)
SIMULATED LOADING TESTS ON BASIS OF SETTLEMENT MEASUREMENTS
A couple of years ago, I developed a method forturning conventional settlement measurements intofull scale loading tests. The program not onlysimulates load test results, but also determines the,eventually unknown, settlement values, at the datethe measurements began. Besides, it makes astatistical adjustment of the measured values. Thenext slide below shows the results of one ofthese tests. In this particular case, the settlementmeasurements began when the column loads wereabout 2/3 of their nominal values.
![Page 69: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/69.jpg)
Curvas de carregamento corrigidas
![Page 70: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/70.jpg)
PROGRAMAS DE
INTERPRETAÇÃO DE
PROVAS DE CARGA
![Page 71: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/71.jpg)
![Page 72: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/72.jpg)
![Page 73: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/73.jpg)
![Page 74: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/74.jpg)
![Page 75: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/75.jpg)
![Page 76: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/76.jpg)
![Page 77: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/77.jpg)
![Page 78: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/78.jpg)
![Page 79: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/79.jpg)
![Page 80: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/80.jpg)
![Page 81: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/81.jpg)
![Page 82: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/82.jpg)
![Page 83: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/83.jpg)
![Page 84: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/84.jpg)
![Page 85: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/85.jpg)
![Page 86: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/86.jpg)
![Page 87: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/87.jpg)
![Page 88: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/88.jpg)
![Page 89: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/89.jpg)
FUNDAÇÕES PROFUNDAS
![Page 90: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/90.jpg)
![Page 91: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/91.jpg)
![Page 92: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/92.jpg)
PROJETOS DE ESTACAS
DÉCOURT, L.
CAPÍTULO 8.1 - FUNDAÇÕES, TEORIA E PRÁTICA – ABMS, ABEF
SÃO PAULO, BRASIL , 1996
![Page 93: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/93.jpg)
PREVISÃO DE CAPACIDADE DE CARGAA FÓRMULA DÉCOURT & QUARESMA
Qu = α qp Ap + β qs As
Qu = α K Np Ap + 10β (Ns/3+1) (kN/m²)
VALORES DE K (kN/m²)
Areias.....................................400Solos intermediários.......200/250Argilas saturadas....................120
![Page 94: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/94.jpg)
Valores do coeficiente α em função do tipo de estaca e solo
* Esses valores são não mais que indicativos, devido a escassez de dados disponíveis.
Escavada
em geral
Escavada
(bentonita)CFA
FDP
(Ômega)Raíz
Injetada
sob altas
pressões
Areias ≤ ,30 ≤ 0,30 ≤ 0,30 0,45 0,50* 1,0*
Solos Intermediários
≤ 0,40 ≤ 0,40 ≤ 0,40 0,45 0,50* 1,0*
Argilas Saturadas
≤ 0,50 ≤ 0,50 ≤ 0,50 0,45 0,50* 1,0*
![Page 95: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/95.jpg)
Valores do coeficiente β em função do tipo de estacae solo
•Esses valores são não mais que indicativos, devido a escassez de dados disponíveis.
Escavada
em geral
Escavada
(bentonita)CFA
FDP
(Ômega)Raíz
Injetada
sob altas
pressões
Areias 0,50 0,60 1,0 1,5* 1,50* 3,0*
Solos Intermediários
0,65 0,75 1,0 1,5* 1,50* 3,0*
Argilas Saturadas
0,80 0,90 1,0 1,5* 1,50* 3,0*
![Page 96: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/96.jpg)
LOADING TESTS: INTERPRETATION AND PREDICTION OF THEIR RESULTS
DÉCOURT, L.
FROM RESEARCH TO PRACTICE IN GEOTECHNICAL ENGINEERING. ASCE, GSP 180
SYMPOSIUM HONORING DR. JOHN H. SCHMERTMANN
NEW ORLEANS, USA, 2008
![Page 97: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/97.jpg)
EXTRAPOLAÇÃO DOS RESULATDOS DOS TESTES DE CARREGAMENTO
![Page 98: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/98.jpg)
PREVISÃO DAS CURVAS CARGAS - RECALQUE
![Page 99: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/99.jpg)
Pontos para prever a curva carga - recalque
![Page 100: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/100.jpg)
![Page 101: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/101.jpg)
βL = 2
![Page 102: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/102.jpg)
EVENTOS DE
PREVISÃO DE CAPACIDADE
DE CARGA E DA CURVA
CARGA-RECALQUE DE
FUNDAÇÕES DIRETAS
E PROFUNDAS
![Page 103: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/103.jpg)
Entre os anos de 1982 e 2012, o autor participou de 5 concursos de previsão de capacidade de carga, a saber:
1º. Caso........................ESOPT II – Amsterdam.…………1982
2º. Caso…………...Texas A&M University – Texas…………1994
3º. Caso..............................SEFE VI – São Paulo.....……2004
4º. Caso.................XV COBRAMSEG – Gramado....….…2010
5º. Caso.......XVI COBRAMSEG – Porto de Galinhas...…2012
![Page 104: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/104.jpg)
5º. CASO - XVI COBRAMSEG
Previsão da capacidade de carga de atrito lateral de duas estacas,uma do tipo Hélice Contínua (CFA) e outra do tipo Ômega (FDP),L=15,0m e d=500,0mm pelo método Décourt e Quaresma e pelomonitoramento.
Estaca Hélice Contínua (CFA) Estaca Omega (FDP)
Qs=81,64tf (D&Q) Qs=107,25tf (D&Q)Qs=61,55tf(monitoramento) Qs=122,0tf (monitoramento)Qs(tf)=71,5 ± 10,1 ou ± 14% Qs(tf)=114,6 ± 7,4 ou ± 6,5%Qs≤73,1tf (PC) Qs≤116,6tf (PC)
Segundo Coutinho et al, 2012, o vencedor do concurso foi JeanRodrigo Ferreira Escobar, que utilizou o Método de Alonso para aestaca Hélice Contínua e o Método Décourt e Quaresma para aestaca Hélice de Deslocamento.
![Page 105: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/105.jpg)
6º. CASO - IV COBRAE
CAPACIDADE DE CARGA DE UM TIRANTE
VENCEDOR: MARCO AURÉLIO DE OLIVEIRA
FÓRMULA UTILIZADA: DÉCOURT & QUARESMA
![Page 106: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/106.jpg)
CLASS A PREDICTIONS AND BENEFITS
DERIVED FROM THEIR ANALYSES
DÉCOURT, L.
ISC - 4
PORTO DE GALINHAS, BRAZIL, 2012
![Page 107: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/107.jpg)
COMENTARIOS RELATIVOS AOS SEIS CASOS
1 – As previsões de capacidade de carga de 8 estacas e de um tiranteefetuadas com base no método Décourt & Quaresma e dados desolo adequados, conduziram a resultados bastante satisfatórios .
2 – As previsões de carga, para recalque de 25,0mm, deramresultados satisfatórios para as 5 sapatas.
3 – As previsões de carga, para recalque de 150,0mm foramtotalmente insatisfatórias, ,demonstrando, claramente, que osprocedimentos de cálculo utilizados eram inadequados.
4 – Deve se enfatizar a imperiosa necessidade de se reconhecer quesolos lateríticos não seguem o que foi estabelecido para solos nãolateríticos.
![Page 108: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/108.jpg)
CONCLUSÕES
![Page 109: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/109.jpg)
1 – SPT
O uso do SPT deve ser descontinuado, devendo esse ensaio ser substituído, de imediato, pelo SPT-T e em futuro próximo , pelo SPT-T sísmico.
2 – Teorias clássicas de capacidade de carga de fundações diretas
São totalmente incorretas e inadequadas e devem, de imediato, deixar de serem utilizadas e acima de tudo, deixar de serem ensinadas nas escolas de engenharia.
![Page 110: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/110.jpg)
3 – Provas de cargaNão necessitam mais dos arcaicos e pouco precisos critérios de interpretação. Seus resultados devem ser normalizados e convertidos na Curva Básica, que é totalmente independente de dimensões e profundidades. O método de rigidez, de aplicação muitíssimo simples e adequada é, a mais útil ferramenta atualmente disponível, para a correta interpretação desses ensaios.
4 – Tensão admissívelO conceito de tensão admissível é uma grande falácia. Um bom projeto de fundações deve almejar recalques iguais e não tensões iguais para todas as sapatas.
![Page 111: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/111.jpg)
5 – Monitoramento de recalques
Trata-se de procedimento de extraordinária importância, além de obrigatório, para edifícios com mais de 60m de altura (aproximadamente 20 andares), de acordo com a Norma NBR 6122:2010 da ABNT.
Essas medidas podem ser complementadas por avaliações das cargas dos pilares, nas datas em que essas medições são feitas, o que permitiria transformá-las em provas de carga.
Assim, um edifício com “n” pilares instrumentados ,poderá vir a ter “n” provas de carga durante a sua execução, conferindo muito mais segurança à obra e permitindo, com grande antecedência, prever eventuais problemas que poderiam vir a ocorrer.
![Page 112: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/112.jpg)
6 – Eventos de previsão de comportamentoPermitem verificar como está a capacidade do engenheiro
de prever o desempenho das fundações.Destaque para a fórmula Décourt e Quaresma, presenteem todas as previsões bem sucedidas.Exemplo notável foi o Evento de 1994 na Texas A&MUniversity organizado pelo Prof. Jean-Louis Briaud, que foi fundamental para a comprovação da falácia das teorias decapacidade de carga de sapatas.Esses concursos comprovaram também,de forma inequívoca, que os solos lateríticos não são suscetíveis deserem tratados como os demais solos. Ignorar Isso significa encarecer dramaticamente o custo de nossosprojetos.
![Page 113: ASSOCIAÇÃO BRASILEIRA DE MECÂNICA DE …portalclubedeengenharia.org.br/arquivo/1511284821.pdfPOULOS, H.G. (2010) “Unfortunately, there is now considerable evidence that demonstrates](https://reader030.vdocument.in/reader030/viewer/2022040921/5e99c06ddbd07527b0461d1a/html5/thumbnails/113.jpg)
MUITO OBRIGADO