Page 1: Authorised Agent - maxder.it Main cat.pdf · JBC Advanced 2010/2045 JBC1 Iron connectors, ESD silicon tube, fasteners. VOC Monitoring VOC Sensor for detecting volatile organic compounds

Authorised Agent

Page 2: Authorised Agent - maxder.it Main cat.pdf · JBC Advanced 2010/2045 JBC1 Iron connectors, ESD silicon tube, fasteners. VOC Monitoring VOC Sensor for detecting volatile organic compounds

Being the first company to introducecomprehensive filter technology into the UK,Bofa (UK) Ltd has unrivalled expertise in thefield of fume elimination and control.

We pride ourselves on having the widest rangeof systems available, together with the

technical knowledge to modify and develop turnkey solutions for the mostdemanding and diverse applications.

Much of our design criteria focus on our customers needs for simple, efficient andcost effective equipment with the product quality and reliability for many years trouble

free operation.

Protecting company personnel and the environment is our objective. For this reasonmany of our customers require product so that they can conform to the latest COSHH

(Control of Substances Hazardous to Health) regulations or who require ISO14001certification.

Free site surveys, 24 hourservice and maintenancesupport, together withCOSHH re-certification arepart of the many servicesavailable

Dave CornellManaging Director

Tip Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3High Volume Extraction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6

High Volume Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8High Volume Entry Level Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7

Machine Soldering . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9Medical and Pharmaceutical . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10

Fabrication and Machine Shop . . . . . . . . . . . . . . . . . . . . . . . . .10Specialised Products - OEM . . . . . . . . . . . . . . . . . . . . . . . .11

Laser Fume Extraction . . . . . . . . . . . . . . . . . . . . . . .12-13

All Bofa Extraction Systems incorporate a progressiveseries of filters designed specifically to maximiselife for both particulate and gas capture

PRE-FILTER

The pre filter is designed solely to protect the life of the

micro filter. For the majority of units, Bofa use a pleated

synthetic media with a separation of typically 95% of

particulate down to 0.8 microns. In cases where larger

amounts of sub micron particulate are generated, a higher

efficiency filter can be fitted or stand alone Bag filter can be

installed to give greater life to the pre filter and ensure

adequate protection to the main filter.

MICRO FILTER

Bofa Micro Filters incorporate a series of bonded webbing

between the pleats. This feature not only ensures even

spacing between each pleat, but also alleviates the possibility

of airflow vibration or collapse through pressure build up

during gradual filter saturation. Each Micro filter is designed

to withstand up to 6 times the maximum operating pressure

for its designated unit, with filter efficiency of 99.997% down

to 0.3 microns and 95% as small as 0.01 microns.

Air filters

Bactiguard air filters, used in various grades of pre and

micro medias have been proven in independent testing to

eradicate a wide range of micro-organisms.

A list of the micro-organisms used in testing can be supplied

on request. Most common types of bacteria referred to are

MRSA, Samonella and E.coli. On fungi, the most common

referred to aspergillus.

GAS FILTER

The standard gas filter is made up of a 50/50 mix of

Activated Aluminium Potassium Permanganate and

Activated Carbon. The media neutralises a broad

base of chemical and VOC (Volatile Organic

Compound) pollutants. A comprehensive range of

specialised filters together with electronic gas

sensing is available for more demanding or diverse

applications.

Gas-Filter

Micro-Filter

Pre-Filter

See Unit Options page for more details.

All filters are produced in accordance with ISO9002 with

micron filtration complying with BS3928. A certificate of

conformity for each filter is available upon request.

PUMP TECHNOLOGY

The pump is the heart of the unit and as such, any

compromise on quality will have an adverse effect on

performance and long term reliability. Bofa use only the

highest quality pumps and motors in all their units. All

pumps are individually matched to the motors and

dynamically balanced accordingly. Each assembly is

produced in accordance with ISO 9002 and CE marked.

Page 3: Authorised Agent - maxder.it Main cat.pdf · JBC Advanced 2010/2045 JBC1 Iron connectors, ESD silicon tube, fasteners. VOC Monitoring VOC Sensor for detecting volatile organic compounds

2 3

System 1, 3, VT2 RangeHigh Vacuum (Tip) Extraction UnitsThe smallest in our range of BOFA High Vacuum Extraction Systems.Designed specifically for portability and extremely low noise levels.

System1 3 VT2

(Air Driven Unit)

Maximum number of Soldering Irons EC 1 3 2US 1 3 2

UNIT SPECIFICATIONS Flow Rate Rated Noise

Dimensions Weight 4.5mm Power Output Level Duct Duct FilterUnit mm H x D x W Kg I/D Hose Unit kW Voltage dBA Size mm Run mtrs Efficiency

System 1 220 x 171 x 171 5 22-24 L/M Linear Pump 0.06 230 1ph <48 - - 99.997

System 3 285 x 270 x 195 12 22-30 L/M Carbon 0.12 230 1ph <40 32 10 99.997Vane Pump

Flow Rate Rated NoiseDimensions Weight 4.5mm Power Output Level Air requirements

Unit mm H x D x W Kg I/D Hose Unit kW Voltage dBA Pressure Flow

System VT2 170 x 150 x 170 1 22-30 L/M Air 0.12 230 1ph <39 6 Bar 0.6 NI/SEjector

System 8, 15 RangeHigh Vacuum (Tip) Extraction UnitsThe medium range of BOFA High Vacuum Extraction Systems. Built-in silencer for extremelylow noise levels ensures a compact portable unit.

System8 15

Maximum number of Soldering Irons EC 8 15US 10 25

Maximum number of Flexi Fume Arms EC 2 4US 3 5

UNIT SPECIFICATIONS Flow Rate Rated Noise

Dimensions Weight 4.5mm Power Output Level Duct Duct FilterUnit mm H x D x W Kg I/D Hose Unit kW Voltage dBA Size mm Run mtrs Efficiency

System 8 460 x 250 x 250 19 22-30 L/M Side Channel 0.2 230 1ph <50 50 200 99.997Blower

System 15 560 x 330 x 330 28.5 22-30 L/M Side Channel 0.37 230 1ph <50 50 200 99.997Blower

Tip Extraction

These high vacuum units are designed to extract and filter fumes and debris through small bore hosesand attachments. Ideally suited for soldering iron tip extraction, vac pens, flexi fume arms and anyapplication requiring close proximity micro extraction.

Tip Extraction AccesoriesITEM Part No. Description

Installation Kits INSKT3 System 3

INSKT8 System 8

INSKT15 System 15

Flexi Fume Arm (inclusive of shut off valve) FFA12/600 12mm x 600mm through bench kit

Flexi Fume Arm (inclusive of shut off valve) FFA12/600/B 12mm x 600mm with bench mounting bracket

Metcal Iron Conversion Kit for 002/SP200 iron METCO1 Iron connector, ESD silicon tube, fasteners and cleaning brush.

Metcal Universal Iron Holder WSF Holder for 002 and SP200 irons.

Weller Mini Iron Conversion Kit WAK Iron clip on kit, stainless steel tube, ESD silicon tube, fasteners, cleaning brush.

Weller Integral Iron WIK Handle, stainless steel tube, ESD silicon tube, fasteners, holder and cleaning brush.

Adcola, Weller, Pace + (fits most other irons) UAK Iron clip on kit, stainless steel tube, ESD silicon tube, cleaning brush, fasteners and holder.

ERSA Tip Tool ERSA1 Iron connector, stainless steel tube, ESD silicon tube, fasteners, cleaning brush.

ERSA Micron Tool ERSA2 Iron connector, stainless steel tube, ESD silicon tube, fasteners, cleaning brush.

ERSA Ergo Tool, Tech Tool, Power Tool ERSA3 Iron connector, stainless steel tube, ESD silicon tube, fasteners, cleaning brush.

Hakko HAKO 1 Iron connector, stainless steel tube, ESD silicon tube, fasteners, cleaning brush.

JBC Advanced 2010/2045 JBC1 Iron connectors, ESD silicon tube, fasteners.

VOC Monitoring VOC Sensor for detecting volatile organic compounds.

System 30, 60, 100 RangeHigh Vacuum (Tip) Centralised Extraction UnitsDue to the high concentration of debris generated from up to 100 operators, these systemshave been designed to keep the unit compact but still utilise a comprehensive filter system. Withthis in mind BOFA have developed a design that incorporates a facility for retaining a highconcentration of particulate within the filter enclosure.All systems have a built-in silencer which projects the filtered air directly upwards. This is consideredto be the best method of evacuation with as little disturbance to ground level dust as possible. Eachsilencer has a collar which facilitates re-direction or external venting of filtered air if required.

System30 60 100

Maximum number of Soldering Irons EC 30 60 100US 50 100 150

Maximum number of Flexi Fume Arms EC 6 12 20US 8 20 30

Flow Rate Rated NoiseDimensions Weight 4.5mm Power Output Level Duct Duct Filter

Unit mm H x D x W Kg I/D Hose Unit kW Voltage dBA Size mm Run mtrs Efficiency

System 30 500 x 550 x 350 30 22-30 L/M Side Channel 0.8 230 1ph <50 50 400 99.997Blower

System 60 615 x 830 x 475 50 22-30 L/M Side Channel 2.2 380/415 <50 50 800 99.997Blower 3 phase

System 100 615 x 830 x 475 52 22-30 L/M Side Channel 2.2 380/415 <50 50 1000 99.997Blower 3 phase

Down to 0.3 micron DOP

Down to 0.3 micron DOP

Down to 0.3 micron DOP

Page 4: Authorised Agent - maxder.it Main cat.pdf · JBC Advanced 2010/2045 JBC1 Iron connectors, ESD silicon tube, fasteners. VOC Monitoring VOC Sensor for detecting volatile organic compounds

4 5

System 200High Volume UnitThe System 200 is the smallest in Bofa’s range of volume extraction systems. This compact unit iscapable of running 1 x 50mm arm, cowl or down tray at 90M3h without the need for inflexible installationpipework. Ideal for factory’s with changing demands which result in production layout changes.The unit comes complete with flexible hose, table bracket and Bofa’s unique flip top flush sealingmounting plate.Maximum number of 50mm Arms EC - 1 US - 1

UNIT SPECIFICATION Air Flow Rated Noise

Dimensions Weight (with Power Output Level Duct Duct FilterUnit mm H x D x W Kg filters fitted) Unit kW Voltage dBA Size mm Run mtrs Efficiency

System 200 380 x 260 x 260 7 90m3h Radial Ventilator 0.058 230 1pH 48 - - 99.997%Down to 0.3 micron DOP

System 400High Volume Unit with Adjustable Flow ControlA compact, versatile and extremely efficient High Volume Extraction System that has beendesigned to incorporate ‘variable air flow control’. Adjustment is made easy by the simple turnof a knob on the unit to facilitate single to multiple user applications.Built in silencer ensures low noise levels to the maximum flow control adjustment.

Maximum number of 32mm Arms EC - 5 US - 7Maximum number of 50mm Arms, Cowls or Down Draft Trays EC - 3 US - 4Maximum number of 75mm Arms, Cowls or Down Draft Trays EC - 2 US - 2

UNIT SPECIFICATION Air Flow Noise Level Noise Level

Dimensions Weight (with Power (min flow) (max flow) Duct Duct FilterUnit mm H x D x W Kg filters fitted) Unit Voltage dBA dBA Size mm Run mtrs Efficiency

System 400 446 x 376 x 376 23 340m3h Radial Ventilator 230 1ph 49 60 75 6 99.997%Down to 0.3 micron DOP

System 500High Volume UnitDesigned specifically for portability and very low noise levels, this unit can be sited directly bythe operator for single user operation or as a central unit having up to forty metres of trunkingconnected for multi-user applications.The built-in silencer has a collar which facilitates re-direction or external venting of filtered air ifrequired.

Maximum number of 32mm Arms EC - 8 US - 10Maximum number of 50mm Arms, Cowls or Down Draft Trays EC - 5 US - 6Maximum number of 75mm Arms, Cowls or Down Draft Trays EC - 2 US - 3

UNIT SPECIFICATION Air Flow Rated Noise

Dimensions Weight (with Power Output Level Duct Duct FilterUnit mm H x D x W Kg filters fitted) Unit kW Voltage dBA Size mm Run mtrs Efficiency

System 500 620 x 500 x 400 40 350m3h Radial Ventilator 0.37 230 1ph 58 75 40 99.997%Down to 0.3 micron DOP

High Volume Extraction

This range of High Volume systems accommodate the removal and filtration of a large air mass from theenvironment. When used in conjunction with our extensive range of arms, hoods, cabinets and flat bedextraction trays, hazardous processes can be undertaken in comfort and safety.All systems have a built in silencer that achieve very low noise levels.

System 250High Volume UnitA compact High Volume Extraction System that can be sited directly by the operator having up to sixmetres of trunking connected to the unit.Maximum number of 32mm Arms EC - 4 US - 4Maximum number of 50mm Arms, Cowls or Down Draft Trays EC - 2 US - 2Maximum number of 75mm Arms, Cowls or Down Draft Trays EC - 1 US - 1

UNIT SPECIFICATION Air Flow Rated Noise

Dimensions Weight (with Power Output Level Duct Duct FilterUnit mm H x D x W Kg filters fitted) Unit kW Voltage dBA Size mm Run mtrs Efficiency

System 250 480 x 260 x 280 10 180m3h Radial Ventilator 0.12 230 1ph 55 75 6 99.997%Down to 0.3 micron DOP

Page 5: Authorised Agent - maxder.it Main cat.pdf · JBC Advanced 2010/2045 JBC1 Iron connectors, ESD silicon tube, fasteners. VOC Monitoring VOC Sensor for detecting volatile organic compounds

6 7

System 1000, 2500, 3500, 4500High Volume Centralised Extraction Units

System1000 2500 3500 4500

Maximum number of 32mm Arms EC 14 18 25 55US 15 18 25 55

Maximum number of 50mm EC 10 16 20 40Arms, Cowls or Down Draft trays US 12 16 25 40Maximum number of 75mm EC 5 8 12 20Arms, Cowls or Down Draft trays US 6 8 12 20

UNIT SPECIFICATIONS Air Flow Rated Noise Level Noise Level Filter

Dimensions Weight (with Power Output (min flow) (max flow) Duct EfficiencyUnit mm H x D x W Kg filters fitted) Unit kW Voltage dBA dBA Size mm 0.3 micron DOP

System 1000 845 x 645 x 530 62 1000m3h Radial Ventilator 1.1 230 1ph 54 - 125 99.997%System 2500* 845 x 645 x 530 75 1500m3h Radial Ventilator 2.2 400 3ph 48 60 125 99.997%System 3500* 1200 x 740 x 600 100 2300m3h Radial Ventilator 5.5 400 3ph 50 64 125 99.997%System 4500*1350 x 1080 x 710 130 3000m3h Radial Ventilator 7.5 400 3ph 52 66 125 99.997%*Adjustable Flow Control

Max duct run supplied on application.

System 700High Volume Unit with Adjustable Flow ControlSimilar in size to the 500 but capable of generating extremely high air flows when needed,using an adjustable flow control.Designed specifically for portability and very low-noise levels, it can be sited directly by theoperator for single user operation or as a central unit having up to forty metres of trunkingconnected for multi-user applications.Systems have a built-in silencer to ensure a compact portable unit. A collar within thesilencer facilitates re-direction or external venting of filtered air if required.

Maximum number of 32mm Arms EC - 12 US - 12Maximum number of 50mm Arms, Cowls or Down Draft Trays EC - 7 US - 7Maximum number of 75mm Arms, Cowls or Down Draft Trays EC - 3 US - 3

UNIT SPECIFICATION Air Flow Noise Level Noise Level

Dimensions Weight (with Power (min flow) (max flow) Duct Duct FilterUnit mm H x D x W Kg filters fitted) Unit Voltage dBA dBA Size mm Run mtrs Efficiency

System 700 620 x 500 x 400 40 510m3h Radial Ventilator 230 1ph 49 64 75 40 99.997%

High Volume Extraction (continued) High Volume Entry Level Units

These compact low cost systems are capable of generating high air flow rates from a range of bench topattachments.Units can be positioned comfortably under the bench with a simple installationkit to connect to the most suitable extraction accessory.

System 300EHigh Volume Entry Level UnitA cost effective unit capable of extracting fumes, with optimal flow rates, for up to two solderingstations using any one of the following attachments:

Maximum number of 50mm Arms, Cowls or Down Draft Trays EC - 2 US - 2Maximum number of 75mm Arms, Cowls or Down Draft Trays EC - 2 US - 2

UNIT SPECIFICATIONS Air Flow Noise

Dimensions Weight (with Power Level FilterUnit mm H x D x W Kg filters fitted) Unit Voltage dBA Efficiency

System 300 450 x 300 x 300 15 320m3h Radial Blower 230 1ph 52 95%Down to 0.5 micron DOP

Higher efficiency filters available

Options:• Variable speed/flow control available• High efficiency filters available (up to 99.997) DOP

System 350EHigh Volume Entry Level UnitA compact low cost system capable of generating high air flow rates having up to six metres oftrunking connected to the system.

Maximum number of 32mm Arms, Cowls or Down Draft Trays EC - 7 US - 7Maximum number of 50mm Arms, Cowls or Down Draft Trays EC - 5 US - 5Maximum number of 75mm Arms , Cowls or Down Draft Trays EC - 4 US - 4

UNIT SPECIFICATIONS Air Flow Noise

Dimensions Weight (with Power Level Duct Duct FilterUnit mm H x D x W Kg filters fitted) Unit Voltage dBA Size mm Run mtrs Efficiency

System 350E 446 x 376 x 376 23 600m3h Radial Blower 230 1ph 60 75 6 95%Down to 0.5 micron DOP

Higher efficiency filters available

Options• Variable speed/flow control available• A range of installation kits to suit accessories required• High efficiency filters available (up to 99.997) DOP

Page 6: Authorised Agent - maxder.it Main cat.pdf · JBC Advanced 2010/2045 JBC1 Iron connectors, ESD silicon tube, fasteners. VOC Monitoring VOC Sensor for detecting volatile organic compounds

8 9

High Volume AccesoriesSelect the type and quantity of arms/cowls or down draft trays required. 50mm diameter are the norm for most operations. 32mmdiameter arms are for small working areas with light soldering (e.g. when using mini irons), whilst 75mm arms are for heavy dutysoldering.The arms are mounted through the bench using BOFA’s unique self sealing sprung flip top connector (except 75mm) or onto the benchusing a mounting bracket.The cowls provide a working area of up to 250mm (10”) out from the front of the cowl. An added advantage is that the iron stand canbe positioned at one end of the cowl to capture the residual fume when the iron is replaced after use. The down draft tray is ideal wherespace is at a premium. The workpiece is positioned on the tray and all fume generated is pulled down through the matrix of holes intothe extraction unit.

TB50Table bracket for 32mm and 50mm

CCC50ESD50mm ESD Cowl

CCC50 50mm Clear Cowl

CCC75ESD75mm ESD Cowl

CCC75 75mm Clear Cowl

CCC75ESDL 75mm ESD cowl with light (not shown)

DDT50ESD50mm ESD Down Draft Tray

DDT75ESD75mm ESD Down Draft Tray

FMP50ESDAutomatic Flush System Seal for 32mm and 50mm

SPAF32ESD-P32mm ESD Stay Put Arm with Funnel

SPAN32ESD-P32mm ESD Stay Put Arm with nozzle

SPAF50ESD-P50mm ESD Stay Put Arm with Funnel

SPAN50ESD-P50mm ESD Stay Put Arm with nozzle

SPAS50ESD-P50mm ESD Stay Put Arm with slot

SPA-300-ESD-P75mm ESD Stay Put Arm unit mounted

SPAF75ESD-P75mm ESD Stay Put Arm with Bench Bracket

1

2

1

2

3

4

5

3

4

5

6

6

7

7

8

8

9

9

10

10

14

14

15

15

11

11

12

13

12

13

System M250, M500, M700, M1000, M2500,M3500, M4500

From small bench top to centralised high through-put machines, BOFA have acomprehensive range of systems for the light to heavy duty users. The BOFArange of machine soldering extraction and filtration systems can be fullyintegrated with your machinery so the system will start and stop automatically.Other options such as a fail-safe signal for system failure and filter replacementcan also be fitted.

UNIT SPECIFICATIONS Rated Filter

Dimensions Weight Flow Rate Power Output EfficiencyUnit mm H x D x W Kg M3/Hr Unit kW Voltage % @ 1µm

System M250 470 x 300 x 300 25 210 Centrifugal 0.12 110/230 99.997Fan

System M500 620 x 500 x 400 40 350 Centrifugal 0.37 110/230 99.997Fan

System M700 620 x 500 x 400 40 510 Centrifugal 0.37 110/230 99.997Fan

System M1000 845 x 640 x 530 62 1000 Centrifugal 1.1 110/230 99.997Fan

System M2500 845 x 640 x 530 75 1500 Centrifugal 2.2 400 3ph 99.997Fan

System M3500 1200 x 740 x 600 100 2300 Centrifugal 5.5 400 3ph 99.997Fan

System M4500 1350 x 1080 x 710 130 3000 Centrifugal 7.5 400 3ph 99.997Fan

UNIT OPTIONSLaser 24v

24v Dual Filter SystemStop/Start Voltage Flow Change Failure Gas Particulate Filter

Signal Freqency Control Signal Signal Monitoring Monitoring Gauge

M250 • • •• • •• • •• ✔

M500 • • •• • • • • ✔

M700 • • ✔ • • • • ✔

M1000 • • • • • • • ✔

M2500 • • ✔ • • • • ✔

M3500 • • ✔ • • • • ✔

M4500 • • ✔ • • • • ✔

Optional • Standard ✔ Unavailable ••

Machine Soldering

Page 7: Authorised Agent - maxder.it Main cat.pdf · JBC Advanced 2010/2045 JBC1 Iron connectors, ESD silicon tube, fasteners. VOC Monitoring VOC Sensor for detecting volatile organic compounds

10 11

Bofa have extraction and purification systems that integrate perfectly with fabrication and machine shopenvironments. For welding, PCB cutting, and other high fume or particulate generating operations. With eitherportable or fully installed centralised systems, hazardous fumes or materials can be removed and filteredefficiently and economically.For Centralised units, control valves at each extraction point ensure maximum utilisation of plant size, with independentseparation filters to collect heavy materials and fluids.Some designs incorporate separation matched with a three stage coalescing pre-filter for containmment of all fluids.Gasses and particulate are the separated to 99.997% DOP.Automatic filter cleaning fascilitates maximum performance with pump management systems to ensure economicalrunning costs.A range of accessories from telescopic arms for large mass extraction to small slotted nozzles, funnels and fish tail stayput assemblies can be used for varied applications.

Typical Applications:• Welding • PCB Cutting and Splitting• Routing• Grinding• Etching• Drilling• Swarf Removal• Lathing

Fabrication & Machine Shop

Many processes in the medical and pharmaceutical industry produce harmful chemical fumes, dust andbacteria that can be removed and retained safely. BOFA produce a wide range of corrosion resistant units forwipe clean or hose down sterile conditions.Our mini pleat HEPA or higher efficiency ULPA filter (99.999 to 0.01 micron) can be supplied with a specificallyformulated anti-bacterial coating to prevent the passage of micro constituents to virus size. Chemical and gas filtermedia’s can be combined to neutralise VOC’s and other chemical sustances.

Typical Applications• Thermal Surgery (Laser or hot tool) • Pill and capsule production• Chemical Formulation• Marking (Date and Batch Coding)• Research and Development• Laboratory Work

Many of our systems are designed for specific applications. In particular the OEM market, so please call our technical helpline forassistance.

A multi-pupose high vacuum system that combinesthe following...• Tip-extraction for soldering irons• Vac pens for collecting debris• Vacuum packagngThis unit has been specificallydesigned for the ‘Open University’for the Beagle 2 Project, where aprobe is being sent to Mars in thepursuit of life forms.

Medical and Pharmaceutical Industry Specialised Products

Options include:• Auto fluid level shut off• Gas/Fluid level alarm• Variable speed/flow control• Dual Voltage and Frequency

OEM Product - Printing InductryA stand alone unit with consumables trolley and tray for the printing cycle on ascreen printing machine.Features include...• 24v Stop-Start interface with printer• Dual voltage/Frequency with voltage selector switch• Filter condition indicator• Vacuum/Flow adjustment• Running light• On/Off stanby mains indicator• Re-settable thermal trip fuses

Compact system designed specifically for applications where fluidsbecome part of the extraction and filtration process.The unit incorporates a cyclone separator matched with a three stagecoalescing pre-filter for containment of all fluids. gasses and particulatesare then separated to Class 100 clean room standard 99.997% DOP.Applications...• Cutting fluid mist• Wet fumes• Substrate retention and fume extraction• Fluid, particulate, gas mixtureOptions...• Auto fluid level shut-off• Gas/Fluid level alarm• Computer interface management system• Variable speed/flow control

OEM Product - Printing InductryA built-in extraction unit for the cleaning cycle onscreen printing machine.

Air filtersBactiguard air filters, used in various grades of pre and micromedias have been proven in independent testing to eradicate a widerange of micro-organisms.A list of the micro-organisms used in testing can be supplied onrequest. Most common types of bacteria referred to are MRSA,Samonella and E.coli. On fungi, the most common referred toaspergillus.

Page 8: Authorised Agent - maxder.it Main cat.pdf · JBC Advanced 2010/2045 JBC1 Iron connectors, ESD silicon tube, fasteners. VOC Monitoring VOC Sensor for detecting volatile organic compounds

12 13

BOFA (UK) Ltd is fast becoming the leading name in laser fume extractionand filtration technology, with a comprehensive range of standard units

designed specifically for the laser industry.

From 70m3h for low power up to 510m3h air flow for more powerful laser applicationsor to extract fumes from multiple heads simultaneously. All systems are available as straight

plug in units or fitted with standard options to interface the extractor with the laser.The full range of ancilliaries offered allows turnkey solutions for all applications.

BOFA installations can be used for more arduous duties such as PET or PVC by usingspecial filter medias and acid resistant contact parts. Safety features available include Particulate,

VOC and HCL gas monitoring options.

FILTERSAll units are fitted as standard with a high capacity bag filter, giving pre-micro filtration

efficiency of 98% down to 1 micron. This gives the laser user long bag filter life and high protectionfor the micro filter.

Our standard particulate/ gas combined filter covers 99.997% capture of particulate down to 0.3microns with activated carbon mixed with potassium permanganate for gas neutralisation. Forheavier or more specialist applications i.e. PET or PVC lasering we have a range of heavy duty

filters to suit specific gas/vapour mixtures and concentrations. For extreme particulate environments, external inline multi-pocket filters are available.

Systems are designed to enable clean and quick filter replacement allowing the user tochange filters within seconds minimising costly down time. This is of particular benefit on high speed production lines.

UNIT OPTIONS• IP56 ENCLOSURE

• 24V INTERFACE STOP-START TO LASER• DUAL VOLTAGE/FREQUENCY

• ADJUSTABLE FLOW (Manual or Automatic)• SIGNAL TO LASER FOR FILTER CHANGE

• SIGNAL TO LASER FOR SYSTEM FAILURE• VOC MONITORING (Either Lamp or Signal)• HCL MONITORING (Either Lamp or signal)

• FILTER CONDITION GAUGE

UNIT SPECIFICATIONS

Flow Rated Noise Duct Bag Filter HEPADimensions Weight Rate Power Output Voltage Level Size/Run Efficiency Efficiency

Unit mm H x D x W Kg M3/HR Unit Kw 1 phase dBA mm/M % @ 1µm % @ 0.3µm

L20 857x330x330 35 70 Side Channel 0.4 110/230 54 50/15 98 99.997Blower

L40 930x370x390 45 160 Side Channel 0.8 110/230 56 50/20 98 99.997Blower

L200 550x260x280 12 85 Centrifrugal 0.05 110/230 61 50/5 98 99.997Fan

L500 1200x500x400 52 310 2 Stage Fan 0.37 110/230 58 75/12 98 99.997

L700 1200x500x400 60 440 2 Stage Fan 0.65 110/230 63 75/15 98 99.997

L800 1200x500x400 65 460 3 Stage Fan I.I 110/230 65 75/30 98 99.997

UNIT OPTIONS24v Laser Laser

Stop/Start Dual Signal SignalIP56 via Voltage Speed Corrosion Filter System VOC HCI Filter

Enclosure Laser Freqency Control Proof Change Failure Monitoring Monitoring Gauge

L20 • • • •• • • • • • ✔

L40 • • • • • • • • • ✔

L200 •• • •• •• •• ✔ •• •• •• •L500 • • •• •• • • • • • ✔

L700 • • •• ✔ • • • • • ✔

L800 • • •• ✔ • • • • • ✔

Optional • Standard ✔ Unavailable ••

Corrosion resistantfilters for PVCapplications