backflow preventers

40
Backflow Preventers

Upload: amina

Post on 30-Jan-2016

73 views

Category:

Documents


0 download

DESCRIPTION

Backflow Preventers. Cross Connection. Direct arrangement of piping which allows the potable water supply to be connected to a line which contains a contamination. Can create a health risk. Types of Backflow. Backpressure Back-siphon age. Backpressure. - PowerPoint PPT Presentation

TRANSCRIPT

Page 1: Backflow Preventers

Backflow Preventers

Page 2: Backflow Preventers

Cross Connection

Direct arrangement of piping which allows the potable water supply to be connected to a line which contains a contamination.

Can create a health risk

Page 3: Backflow Preventers

Types of Backflow

Backpressure

Back-siphon age

Page 4: Backflow Preventers

Backpressure

The reversal of normal flow in a system due to an increase in downstream pressure that is above the supply pressure

Page 5: Backflow Preventers

Backpressure

Normal flow in a system.

Page 6: Backflow Preventers

Backpressure

Increase in downstream pressure changes flow.

Page 7: Backflow Preventers

Backpressure

Customers complained of bitter taste in the soft drinks.

Over 300 people were served during this period.

Page 8: Backflow Preventers

Back-siphon age

The reversal of normal flow in a system caused by a negative pressure or vacuum in the supply piping.

Page 9: Backflow Preventers

Back-siphon age

Normal flow in a system.

Page 10: Backflow Preventers

Back-siphon age

reversal of normal flow in a system caused by a negative pressure

Page 11: Backflow Preventers

Back-siphon age

Exterminator left hose in dilution during service.

Water department repairing a water line.

Page 12: Backflow Preventers

Types of Backflow Preventer

Air Gap Double Check Backflow Preventers Double Check Detector Preventers Reduced Pressure Backflow Preventers Silent Check Valves Hose Bib Vacuum Breakers Anti-siphon Vacuum Breakers

Page 13: Backflow Preventers

Air Gap

Industrial processing applications

Rarely used in plumbing systems

Page 14: Backflow Preventers

Double Check Backflow Prevention Assemblies

FDC Series Used as a protection of all direct

connections through which foreign material might enter the potable system in concentration which would not constitute a health hazard.

1/2” – 10” Devices

Page 15: Backflow Preventers

1/2” – 2” FDCDouble Check Backflow Prevention Assemblies

Bronze Bodies Will also offer Low Lead for California

Market.

Page 16: Backflow Preventers
Page 17: Backflow Preventers

1/2” – 2” FDCCheck Valve Assembly

Page 18: Backflow Preventers

1/2” – 2” FDCCheck Valve Assembly

Page 19: Backflow Preventers

1/2” – 2” FDCCheck Valve Assembly

Page 20: Backflow Preventers

2 1/2” – 10” FDCDouble Check Backflow Prevention Assemblies

Ductile iron bodies with epoxy coating

Page 21: Backflow Preventers
Page 22: Backflow Preventers

2 1/2” – 10” FDCCheck Valve Assembly

Page 23: Backflow Preventers

Double Check Detector Assemblies

DCDA Series Incorporates a meter to detect and

measure leaks and unregulated usage 2 1/2” – 10” sizes

Page 24: Backflow Preventers

Reduced Pressure Backflow Prevention Assemblies

FRP Series Used on all direct connections where

there is the possibility of contamination by a substance that has a potential health hazard

1/2” – 10” Devices

Page 25: Backflow Preventers

1/2” – 2” FRPReduced Pressure Backflow Prevention Assemblies

Bronze Bodies Will also offer Low Lead for California

Market.

Page 26: Backflow Preventers
Page 27: Backflow Preventers

1/2” – 2” FRPRelief Valve Assembly

Page 28: Backflow Preventers

1/2” – 2” FRPRelief Valve Assembly

Page 29: Backflow Preventers

2 1/2” – 10” FRPReduced Pressure Backflow Prevention Assemblies

Ductile iron bodies with epoxy coating

Page 30: Backflow Preventers
Page 31: Backflow Preventers

2 1/2” – 10” FRPCheck Valve Assembly

Page 32: Backflow Preventers

2 1/2” – 10” FRPRelief Valve Assembly

Page 33: Backflow Preventers

2 1/2” – 10” FRPRelief Valve Assembly

Page 34: Backflow Preventers

2 1/2” – 10” FRPCheck Valve Assembly

Page 35: Backflow Preventers

Silent Check Valve

CV Series Low Lead devices Available in Threaded or Sweat

applications

Page 36: Backflow Preventers

Hose Bib Vacuum Breaker

HBVB Series Used wherever there is a possibility of a

hose being attached which could be introduced to a contaminant.

Attach to sill cocks and threaded faucets

Available in Rough Brass or Chrome Plated

Page 37: Backflow Preventers

Anti-siphon Vacuum Breaker

ASVB Series Incorporates an atmospheric vent in

combination with a check valve. Cannot be used under continuous

pressure Attach to sill cocks and

threaded faucets Available in Rough Brass

or Chrome Plated

Page 38: Backflow Preventers

Anti-siphon Vacuum Breaker

ASVB Series Typical installation

Page 39: Backflow Preventers

Pressure Vacuum Breaker

PVB Series Used in systems to protect from cross-

connection where it is not subjected to backpressure

Can be used under continuous pressure

Page 40: Backflow Preventers

Pressure Vacuum Breaker

PVB Series Typical installation