bgc fibre cement · fibre cement detail 1:2.5 @ a4 bgc stratum™ and stratum™ duodate (vertical...
TRANSCRIPT
GC
PROFILE
B
DETAIL
Fibre Cement
1:2.5 @ A4
DATE
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
SCALE
DETAIL NO.
Foundation Detail
SV-01
paving or 175m
m m
in to
unprotected ground
15
50
BGC stratum™ (fixed vertically) with
all cut edges sealed before fixing.
Durabarrier™ or aproved breather
type building underlay.
BGC Horizontal
cavity batten.
65 x 2.87mm Roundrive ring
shank nail fixings (typical).
BGC Vermin proof
vent strip or similar.
Finished ground
level.
100m
m m
in to perm
anent
75
Conncrete Slab
or blockwork.
Timber bottom
plate on D.P.C
Timber framing
May 2019
1:2 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Typical Plank Joint Detail
SV-02
GCB Fibre Cement
300mm (plank width)
276 (effective cover)
50 16
12
6mm continuous bead of Bostik
Seal 'N' Flex FC to plank lap
(typical).
Durabarrier™ or approved
breather type building
underlay.
BGC Horizontal
cavity batten
Timber framing
65 x 2.87mm Roundrive
ring shank nail fixings (to
dwang/nog).
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
BGC Horizontal
cavity batten
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
May 2019
GCB Fibre Cement
1:2 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Internal Corner Detail
SV-03
30
45
BGC Horizontal
cavity batten.
Durabarrier™ or approved breather
type building underlay continuous
around corner.
Timber framing
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
65 x 2.87mm Roundrive ring
shank nail fixing.
6mm continuous bead of Bostik
Seal 'N' Flex FC to plank edges.
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing (trimmed edge).
BGC Horizontal
cavity batten
BGC Internal aluminium corner
flashing.
65 x 2.87mm Roundrive ring
shank nail fixing.
Durabarrier™ or approved
breather type building underlay.
Timber framing (as indicated).
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
Lap can be removed prior toinstallation if preferred
May 2019
GCB Fibre Cement
1:2 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
External Corner Detail
SV-04
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
Timber framing
Durabarrier™ or approved breather type
building underlay continuous around corner.
Durabarrier™ or approved
breather type building
underlay.
BGC Horizontal
cavity batten.
45
45
65 x 2.87mm Roundrive ring
shank nail fixing.
6mm continuous bead of
Bostik Seal 'N' Flex FC to both
edges.
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing (trimmed edge).
BGC External aluminium
corner flashing.
65 x 2.87mm
Roundrive ring shank
nail fixing.
BGC Horizontal
cavity batten.
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
Lap can be removed prior toinstallation if preferred
May 2019
1:2 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Window Head Detail
SV-05
GCB Fibre Cement
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
5
g
a
p
Durabarrier™ or approved breather
type building underlay continuous
around corner.
BGC Horizontal cavity
batten.
65 x 2.87mm Roundrive ring
shank nail fixing.
BGC Horizontal cavity
batten
15
10
min.
min.
PC Aluminium head flashing with 15° slope and 20mm
stop ends. Ensure MS Sealant to flange head and head
flashing junction in very high & Extra High Wind Zones
and SD pressure.
PC Aluminium window joinery.
Flashing tape to corners.
Reveal head liner.
Timber framing (as indicated).
Internal wall lining.
Additional layer of flexible
flashing tape or building
underlay lapped over head
flashing.
Air seal over backing rod.
Temporary timber packer
remove after finishing.
7.5m
m m
in
35m
m
flashing
cover
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing (trimmed edge).
BGC Vermin proof vent
strip or similar
May 2019
1:2 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Window Jamb Detail
SV-06
GCB Fibre Cement
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
20 10
10mm min. cover to Stratum™ by
window joinery.
20mm min. overhang of
head flashing.
7.5mm min.
Reveal jamb liner
Air seal over backing rod.
H3.1 timber packer
Flexible flashing tape to corners - to
be continuous along sill, 100mm
min. up each jamb and 50mm into
face of building underlay.
Foam seal tightly finished against
Stratum.™
Line of head flashing above.
Internal wall lining.Timber framing (as
indicated).
BGC Horizontal cavity
batten.
Durabarrier or approved
breather type building underlay.
65 x 2.87mm Roundrive ring
shank nail fixing.
BGC Stratum™ (fixed
vertically) with all cut edges
sealed before fixing.
Note -
Continuous bead of
sealant to junction.
**1
**1
May 2019
Window Sill Detail
1:2 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
B
SV-07
GC Fibre Cement
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
7.5m
m m
in.
PC Aluminium window
joinery.
.
8mm min. cover to Stratum™ by
window joinery.
BGC 'J' Flashing sealed to top
of Stratum.™
Foam seal tightly finished against
'J' Flashing.
65 x 2.87mm Roundrive ring
shank nail fixing.
BGC Horizontal
cavity batten.
BGC Stratum™ (fixed vertically) with all cut
edges sealed before fixing.
Durabarrier™ or approved breather
type building underlay.
Timber framing (as indicated).
Internal wall lining
Flexible flashing tape wrapped around sill
- to be continuous around sill, 100mm
min. up each jamb and 50mm into face
of building underlay.
Reveal sill liner.
Air seal over backing rod.
H3.1 timber packer.
Sill support bar.
May 2019
812
Timber framing
(as indicated).
Polythene bond breaker
tape.
Durasheet™ soffit lining on
H1.2 framing.
Bostik Safe Seal or similar
BRANZ appraised sealand over
bond breaker.
BGC Stratum™ (fixed vertically) with
all cut edges sealed before fixing.
Durabarrier™ or approved
breather type building
underlay.
H3.1 treated timber
packer - continuous.
Nog / dwang - offset to
block airflow into roof
space.
65 x 2.87mm Roundrive ring
shank nail-fixing.
PROFILE
DETAIL
1:2.5 @ A4
DATE
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
SCALE
DETAIL NO.
Soffit Detail
SV-08
GCB Fibre Cement
May 2019
Profiled H3.1 Scotia by others.
(optional)
GCB
PROFILE
Fibre Cement
DETAIL
1:2.5 @ A4
DATE
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
SCALE
DETAIL NO.
Inter-storey Drainage Detail
SV-09
5
15
35
35
12
min cover
min cover
Durabarrier™ or approved
breather type building underlay.
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
BGC Horizontal
cavity batten.
BGC Vermin proof vent strip or
similar (set to provide 15mm min
drop edge to cladding).
Custom made aluminium
inter-storey "z' flashing with
15° slope.
BGC Horizontal
cavity batten.
65 x 2.87mm Roundrive ring
shank nail-fixing.
65 x 2.87mm Roundrive ring
shank nail-fixing.
BGC Stratum™ (fixed vertically) with
all cut edges sealed before fixing.
Durabarrier™ or approved
breather type building underlay.
Flexible flashing tape or building
underlay lapped over flashing
upstand.
Mid floor flooring
- finish 10mm back from
external wall framing.
Timber framing (as indicated).
Timber framing (as indicated).
Mid floor structure
May 2019
BGC Stratum™ (fixed vertically) with
all cut edges sealed before fixing.
Durabarrier™ or approved
breather type building underlay.
Nog / dwang
GCB Fibre Cement
1:2 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Plank Joint Detail (Longitudinal)
SV-10
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
12
12
65 x 2.87mm Roundrive ring
shank nail fixing.
BGC Horizontal
cavity batten
65 x 2.87mm Roundrive ring
shank nail fixing.
BGC Stratum™ (fixed vertically) with
all cut edges sealed before fixing.
20°-45° end cuts, ensure primed or
sealed prior to adhering with Bostik
Seal 'N' Flex FC
May 2019
100m
m m
in
Enclosed deck
structure
15
mem
brane upstand
Floor structure
150m
m
Cavity Batten Note:
Refer to cavity batten layout
for batten sizes, types,
spacing's & fixings.
50m
m m
in
50m
m
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Enclosed Deck Detail
Cavity ConstructionSV-11
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
BGC Horizontal cavity batten.
65 x 2.87mm Roundrive ring
shank nail fixing (typical).
Durabarrier™ or approved
breather type building
underlay.
Timber Bottom plate
on D.P.C (concrete
floor only)
Continuous Vermin proof
BGC vent strip or similar.
Water proof decking
membrane to carry up
behind building wrap past
wall framing bottom plate.
Corner
fillet
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Window Head/Jamb Junction Detail
Cavity ConstructionSV-12
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Note where Durabarrier™ is used
flashing tape must be applied to the
entire opening
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
Fold ends of head flashing
to form stop ends
Flashing tape over wall
underlay fitted around
corner as shown
Durabarrier™ or
approved breather type
Building underlay with
flexible flashing tape to
corners.
BGC Stratum™ (fixed
vertically) with all cut
edges sealed before fixing.
Flashing tape over
flashing (alternatively
use extra layer of wall
underlay)
BGC Horizontal
cavity Batten.
Timber Lintel.
Vermin Proof BGC
20mm Vent strip
Head flashing with 15°
min slope 5mm min gap
below BGC Stratum™
Timber framing.
H3.1 treated
SG8 timber
cavity batten
Cut head flashing to continue
past window opening
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Window Sill/Jamb Junction Detail
Cavity ConstructionSV-13
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
50m
m m
in lap
5
0
m
m
m
i
n
l
a
p
Note where Durabarrier™ is used
flashing tape must be applied to the
entire opening
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
100m
m m
in lap
Flashing tape over
wall underlay full
width of opening.
Sill support bar
BGC Horizontal cavity batten.
BGC Stratum™ (fixed
vertically)with all cut
edges sealed before
fixing.
Durabarrier™ or approved
breather type building
underlay.
H3.1 treated SG8
timber cavity batten.
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Eaves With No Soffit Detail
Cavity ConstructionSV-15
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
50mm
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
Roofing underlay draining into spouting.
Min over hang of roofing beyond fascia.
Eaves flashing as required in accordance
with NZBC Acceptable Solution E2/AS1
Fig 45 by roofer.
Ensure that Stratum™ projects
above top of fascia.
Spouting.
H3.2 timber fascia of width to suit
spouting brackets and falls by others.
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
Durabarrier™ or approved
breather type building
underlay.
Internal linings.
Solid blocking.
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Meter Box Head Detail
Cavity ConstructionSV-16
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
35mm Min upstand
to head flashing
35
10
5
15
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
Note. Where Durabarrier™ is used
flashing tape must be applied to the
entire opening
Timber framing
7.5m
m M
in.
BGC Horizontal cavity batten.
65 x 2.87mm Roundrive ring
shank nail fixing (typical).
Continuous Vermin proof
BGC vent strip or similar.
15mm min overhang.
5mm min gap.
10mm min flashing cover.
Meter box by others.
Colorsteel head flashing
with 15° fall & 20mm stop
ends.
Aluminium angle to be continuous
around meter box. Screw fix and
seal.
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
Durabarrier™ or approved
breather type building
underlay. dressed into
opening with flexible
flashing tape to corners.
Air seal over PEF rod.
H3.1 timber packer.
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Meter Box Jamb Detail
Cavity ConstructionSV-17
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
20
10 min cover
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
Note. Where Durabarrier™ is used
flashing tape must be applied to the
entire opening
7.5mm Min.
Durabarrier™ or approved
breather type building
underlay. dressed into
opening with flexible
flashing tape to corners.
BGC Stratum™ (fixed
vertically) with all cut
edges sealed before
fixing.
Head flashing to extend
20mm min past meter box
angle.
Continuous sealant over
bond breaker to extend to
top of angle.
Optional 40 x 18 H3.2
precut timber scriber.
Meter box by others.
Line of head flashing over.
Aluminium angle to be continuous
around meter box. Screw fix and
seal.
H3.1 timber packer.
Air seal over PEF rod.
Timber framing.
BGC Horizontal cavity batten.
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Meter Box Sill Detail
Cavity ConstructionSV-18
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
10 M
in.
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
Note. Where Durabarrier™ is used
flashing tape must be applied to the
entire opening
7.5m
m M
in.
Durabarrier™ or approved
breather type building
underlay. dressed into
opening with flexible
flashing tape to corners.
Continue wall underlay
around framing.
Meter box by others.
Air seal over PEF rod.
H3.1 timber packer.
Aluminium angle to be continuous
around meter box. Screw fix and
seal.
10mm min cover of Stratum™
to metal angle.
Wall underlay and
flexible flashing tape.
Continuous sealant over
bond breaker.
BGC Horizontal cavity batten.
65 x 2.87mm Roundrive ring
shank nail fixing (typical).
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Enclosed Balustrade-Wall Junction 3D
Cavity ConstructionSV-19
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
1
0
0
m
m
m
i
n
50mm min
5° min
slope
5
0
m
m
m
i
n
SADDLE FLASHING
5° min
slope
FLEXIBLE FLASHING INSTALLATION
Timber framing.
Flexible flashing tape
dressed up and securely
adhered to building
underlay at rear of
cavity.
Flexible flashing tape
dressed min 50mm
down face of battens.
Flashing tape continuous
around corner over building
underlay (100mm wide
each side)
BGC Horizontal cavity
batten.
BGC Stratum™ (fixed
vertically)with all cut
edges sealed before
fixing.
BGC Horizontal cavity
batten
BGC Stratum™ (fixed
vertically) with cut edges
sealed before fixing.
Lower edge of cladding.
Rivet through sealant.
Capping flashing.
Flashing tape to separate
metal capping and treated
timber packer.
Timber framing.
Durabarrier™ or approved
breather type building
underlay.
Timber framing.
Durabarrier™ or approved
breather type building
underlay.
Saddle flashing
behind cladding.
Two lines of sealant to
capping and flashing.
BGC Internal aluminum
corner flashing behind
saddle flashing and
cladding.
Battens behind
saddle flashing
and cladding.
Two lines of
sealant to
capping and
flashing.
H3.1 treated SG8 timber
cavty batten set 40mm
back from corner.
Sloped packer to extend
across cavity at wall
junction.
Durabarrier™ or approved
breather type building
underlay.
6mm continuous bead
of Bostik Seal 'N' Flex
FC to plank edges.
May 2019
BGC Horizontal cavity batten.
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Enclosed Balustrade/Parapet Detail
Cavity ConstructionSV-20
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Z
Z
Note:
Z = Refer to NZBC E2 / AS1 Table 7 for flashing cover requirements
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
BGC Horizontal cavity batten.
65 x 2.87mm Roundrive ring
shank nail fixing (typical).
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
Flashing tape continuous around top of
framing over building underlay.
Sloping H3.1 treated timber
packer to form min 5°
slope.
Metal flashing with 5°
slope on flashing tape or
roof underlay to separate
metal capping and
treated timber packer. Fix
through sides only.
Metal flashing to have birds
beak fold if used as inside
face for enclosed decks.
Durabarrier™ or approved
breather type buidling
underlay.
H3.1 timber framing
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Enclosed Balustrade-Wall Junction Detail
Cavity ConstructionSV-21
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
150mm minimum to face
of window or door jamb stud
40mm min
BGC internal aluminium
corner flashing.
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
BGC horizontal cavity batten.
6mm continuous bead of Bostik
Seal 'N' Flex FC to plank edges
30
45
BGC horizontal cavity batten.
Line of sloping H3.1 treated
packer above show dashed.
Durabarrier™ or approved
breather type building underlay.
Flashing tape continuous
around corner over building
underlay (100mm each
side).
65x2.8mm Roundrive ring shank galv nail.
Timber framing as indicated.
Lap can be removed prior toinstallation if preferred
May 2019
Lap can be removed prior to
installation if preferred
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Gutter to Wall Junction
Cavity ConstructionSV-22
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
f
a
l
l
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
BGC horizontal cavity batten
BGC Verimn proof vent
strip or similar.
Durabarrier™ or approved
breather type building underlay.
BGC Stratum™ (fixed Vertically)
with all cut edges sealed before
fixing.
Flexible flashing tape lapped
over apron flashing upstand.
Parallel apron flashing to
extend over two crests.
Parallel apron flashing
with stop end to deflect
water into gutter.
Transition tray flashing
to underside of roofing
in accordance with
NZBC E2/AS1.
External gutter to
be kept 10mm
clear of cladding.
Fascia with
transition tray
flashing.
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Parallel Apron Flashing Detail
Cavity ConstructionSV-23
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
35
mm
min
110m
m
75m
m
Note:
x = Refer to NZBC E2 / AS1 Table for
flashing cover requirements
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
x
15m
m
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
BGC Horizontal cavity batten.
65 x 2.87mm Roundrive ring
shank nail fixing (typical).
5mm max gap for
notched down turn.
110mm upstand flashing
with 10mm hem & cover
of two crests.
Vermin proof BGC
continuous vent
strip.
Durabarrier™ or approved
breather type building
underlay or flexible
flashing tape lapped over
apron flashing.
Support nog
Timber framing
Underlay carried up face of
framing behind upstand
flashing.
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Transverse Apron Flashing Detail
Cavity ConstructionSV-24
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
x
125m
m
35m
m
min
Note:
x = Refer to NZBC E2 / AS1 Table for
flashing cover requirements
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
15
75m
m
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
BGC Horizontal cavity batten.
65 x 2.87mm Roundrive ring
shank nail fixing (typical).
Vermin proof BGC
continuous vent
strip.
Apron flashing 125mm upstand
flashing with hem.
Selected roofing material with upturn.
Roof framing.
Durabarrier™ or approved
breather type building
underlay or flexible flashing
tape lapped over apron
flashing.
Support nog
Timber framing
Underlay carried up face of
framing behind upstand
flashing.
May 2019
GCB Fibre Cement
1:5 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Pipe Penetration Detail
Cavity ConstructionSV-25
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
Cavity Batten Note:
Refer to cavity batten
layout for batten sizes,
types, spacing's & fixings
Cladding fixing note:
Refer to cladding fixing
layout for all fixing types
& spacing's
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
BGC Stratum™ (fixed vertically)
with all cut edges sealed before
fixing.
BGC Horizontal cavity batten.
65 x 2.87mm Roundrive ring
shank nail fixing (typical).
Flexible flashing tape adhering around pipe
and onto building underlay (100mm lap to
underlay and 25mm to pipe)
Pipe with 5° slope.
Sealant with backing rod.
Flange to protect sealant
from exposure to sunlight.
Durabarrier™ or approved
breather type building
underlay.
Air seal all round
Where possible,
provide outwards fall
to pipework for
water run-off.
Air seal all round
Solid backing around
pipe penetration.
May 2019
GCB Fibre Cement
1:25 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Batten Layout - Elevation
SV-GA1
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
600
600
600
600
Max. nog / dw
ang spacings.
Inter-storey
Door
Window Opening
External
Corner
Typ. Plank Joint
Foundation
Internal
Corner
SoffitSV08
SV03
SV02
SV06
SV05
SV01
SV07
SV04
SV09
(over framing)
GCB Fibre Cement
1:25 @ A4
DATE
SCALE
DETAIL NO.
PROFILE
DETAIL
Plank Layout - Elevation
SV-GA2
BGC Stratum™ and Stratum™ Duo
(Vertical Installation)
Inter-storey
Door
Window Opening
External
Corner
Typ. Plank Joint
Foundation
Internal
Corner
Soffit
Longitudinal
Joint
SV08
SV03
SV02
SV06
SV05
SV01
SV07
SV10
SV04
SV09
(over framing and battens)
May 2019