Built-To-Order, 2 Week Shipment Solid State Reduced Voltage Starters 4,160 Volt MVRMX Series 0 to 1,500 HP or 1,501 to 3,000 HP Benshaw has analyzed and value engineered our MV SSRV Engineered-To-Order product options, and developed a modular architecture, to offer those options most ordered on a Built-To-Order program. This has enabled us to offer you a customized product with a reduced lead time. Our goal is to optimize our response to meet your mission critical application needs. The RediStart CFMVRMX series with MX 3 technol- ogy is a fully integrated, programmable family of Class E2 load break/combination solid state start- ers. This integrated design includes control and power electronics, bypass and isolation contactors that reduce maintenance and operating costs when compared to other methods. Key Advantages: Protect machinery from failure and excessive maintenance caused by mechanical shock during starting or stopping. The RediStart MVRMX provides smooth, stepless acceleration and controlled deceleration. Protect electrical systems from disruptive voltage drops and power outages caused by motor locked rotor inrush current. The RediStart MVRMX starter precisely controls the current ramp during start up. Protect mission critical motors from failure or un- scheduled outages caused by machine or electrical system faults. The RediStart MVRMX starter pro- vides complete, high performance, coordinated line monitoring, motor control and protection. Description Specification Starting Method Closed Loop Current Control Ramp Torque Ramp Power Ramp (kW) Voltage Ramp Linear Accel/Tach Feedback Power Ratings Reference Table A (next page) Control Input 120 Vac or Dry Contact, 2 or 3 Wire Standard Insulation Test 2X RATED V + 2,000 V Nominal Voltage Ratings 4.16 kV Ambient Temperature 0 – 40° C to 3,300 ft. Frequency Range 23 to 72 Hz on Control Board Overall Efficiency (W/Bypass) 99.5% Metering Functions 47 Parameters Relay Outputs 24 Functions Over/Under Voltage Protection 10 to 30% Power Loss (W/Bypass) <0.1 Watt/Amp/Phase Transient Protection DV/DT Circuits/Phase PIV Ratings 4 kV: 12,000 V SCR Firing Technique Hard Gate Continuous Block Fiber Optic Firing Basic Impulse Level 45 kV Short Circuit Current Rating 350 MVA UL/CUL Yes POWER SECTION FEATURES:

Upload: doanminh

Post on 04-Jun-2018

214 views

Category:

Documents


0 download

TRANSCRIPT

Page 1: Built-To-Order, 2 Week Shipment Solid State Reduced ...amaral-automation.com/wp-content/uploads/2013/02/MediumVoltage... · Built-To-Order, 2 Week Shipment Solid State Reduced Voltage

Built-To-Order, 2 Week Shipment Solid State Reduced Voltage Starters4,160 Volt MVRMX Series 0 to 1,500 HP or 1,501 to 3,000 HP

Benshaw has analyzed and value engineered our MV SSRV Engineered-To-Order product options, and developed a modular architecture, to offer those options most ordered on a Built-To-Order program. This has enabled us to offer you a customized product with a reduced lead time. Our goal is to optimize our response to meet your mission critical application needs.

The RediStart CFMVRMX series with MX3 technol-ogy is a fully integrated, programmable family of Class E2 load break/combination solid state start-ers. This integrated design includes control and power electronics, bypass and isolation contactors that reduce maintenance and operating costs when compared to other methods.

Key Advantages:

Protect machinery from failure and excessive maintenance caused by mechanical shock during starting or stopping. The RediStart MVRMX provides smooth, stepless acceleration and controlled deceleration.

Protect electrical systems from disruptive voltage drops and power outages caused by motor locked rotor inrush current. The RediStart MVRMX starter precisely controls the current ramp during start up.

Protect mission critical motors from failure or un-scheduled outages caused by machine or electrical system faults. The RediStart MVRMX starter pro-vides complete, high performance, coordinated line monitoring, motor control and protection.

Description SpecificationStarting Method Closed Loop Current Control Ramp

Torque Ramp

Power Ramp (kW)

Voltage Ramp

Linear Accel/Tach Feedback

Power Ratings Reference Table A (next page)

Control Input 120 Vac or Dry Contact, 2 or 3 Wire

Standard Insulation Test 2X RATED V + 2,000 V

Nominal Voltage Ratings 4.16 kV

Ambient Temperature 0 – 40° C to 3,300 ft.

Frequency Range 23 to 72 Hz on Control Board

Overall Efficiency (W/Bypass) 99.5%

Metering Functions 47 Parameters

Relay Outputs 24 Functions

Over/Under Voltage Protection 10 to 30%

Power Loss (W/Bypass) <0.1 Watt/Amp/Phase

Transient Protection DV/DT Circuits/Phase

PIV Ratings 4 kV: 12,000 V

SCR Firing Technique Hard Gate Continuous Block

Fiber Optic Firing

Basic Impulse Level 45 kV

Short Circuit Current Rating 350 MVA

UL/CUL Yes

PoweR Section FeatuReS:

Page 2: Built-To-Order, 2 Week Shipment Solid State Reduced ...amaral-automation.com/wp-content/uploads/2013/02/MediumVoltage... · Built-To-Order, 2 Week Shipment Solid State Reduced Voltage

Exit / Landing Options

Top exit w/landing pad = T

Bottom exit w/landing pad = B

Top or bottom exit landing on bypass contactor = C Enclosure Options

NEMA 12 = 12

NEMA 12 with space heater = SH

NEMA 3R enclosure option = 3R

Service Entrance Rated (for stand-alone single units)

Yes = S

No = N

Bus Splice Options (must match bus option selected)

800 A non-insulated bus splice = 8N

800 A insulated bus splice = 8I

1,200 A non-insulated bus splice = 1N

1,200 A insulated bus splice = 1I

2,000 A non-insulated bus splice = 2N

2,000 A insulated bus splice = 2I

None required = NR

Communications Options (RS-485 Modbus RTU standard)

DeviceNet = D

Ethernet = E

Profibus = P

None = N

RTD Options (100 ohm platinum)

8 channel RTD = 2

16 channel RTD = 4

None = N

Build your customized starter!Only one option can be selected from each group, with the exception of the ‘Control Options’ section.

Add the appropriate code (noted in red), for the options chosen, to the code string in the center of the page.

Control Options Choose an option for each bullet

•ATLoption*= A, None = N

•Greenstartpushbutton&redstop extendedpushbutton*= B, None = N

•Redrunlight&greenstoplight= C, None = N

•Amberfaultlight&blackreset push button = D, None = N

•Local-off-remote3-position switch = E, None = N

•Emergencystoppushbutton= F, None = N

*indicatesATLoptioncomeswithStartandStopPushbuttonsi.e.StartStopPushbuttonscannot be selected.

No selection = keypad control. Recommend ‘E’ stop option be selected.

Choose Core Unit0 to 1,500 HP = MVB41

1,501 to 3,000 HP = MVB43

Bus Options+

800 A non-insulated bus = 8N

800 A insulated bus = 8I

1,200 A non-insulated bus = 1N

1,200 A insulated bus = 1I

2,000 A non-insulated bus = 2N

2,000 A insulated bus = 2I

None required = NR

Motor Current25 A = 025

26 to 45 A = 045

46 to 55 A = 055

56 to 80 A = 080

81 to 90 A = 090

91 to 133 A = 133

134 to 170 A = 170

171 to 225 A = 225

226 to 330 A = 330

331 to 360 A = 360

TABLE A

Motor Amps / HP Starter Rating

<25/200 500% for 30 sec.

<45/350 500% for 30 sec.

<55/400 500% for 30 sec.

<80/600 500% for 30 sec.

<90/700 500% for 30 sec.

<133/1000 500% for 30 sec.

<170/1250 350% for 30 sec.

<225/1700 500% for 30 sec.

<330/2500 350% for 30 sec.

<360/3000 350% for 30 sec.

Core Unit Motor Current Exit / Landing Option

Enclosure Option

Service Entrance Rated

Ground Fault

Bus Option

Bus Splice Option

Communication Option

RTD Option

Control Option(s)

END

START

Option Zero Sequence Ground Fault Ct 2000:1(Residual included)

Yes = G

No = N

Motor currents vs. HP are typical, confirm actual motor current.Service factor not accounted for, adjust if required.

+Bus not required for single stand-alone unit.Bus is required for connection of 2 or more units. Any unit with bus will require additional MLO section. Please contact the factory for pricing and delivery.

NEW Optional Safety Feature: Benshaw’s answer to remote open/close disconnect ability. Please contact factory and reference part number EMO-425D (Electric Motor Operator).

Example: A 3,000 HP (MVB43), 225 A (225) unit with the following options: bottom exit w/landing pad (B), NEMA 12 Enclosure (12),ServiceEntranceRated(S),withGroundFault(G), 1,200 A non-insulated bus (1N), 1,200 A non-insulated bus splice (1N), with DeviceNet (D), 8 channel RTD (2),withoutATLoption(N), with start and stop buttons (B), without run and stop lights (N), without fault and reset lights (N), with a local-off-remote switch (E), with emergency stop push button (F) would build the following code string: MVB43225B12SG1N1ND2NBNNEF

Page 3: Built-To-Order, 2 Week Shipment Solid State Reduced ...amaral-automation.com/wp-content/uploads/2013/02/MediumVoltage... · Built-To-Order, 2 Week Shipment Solid State Reduced Voltage

MKT 125-008

Visit us online at benshaw.cwfc.com and benshawexpress.com, or contact: BENSHAW, Inc.

615 Alpha DrivePittsburgh, PA 15238

Phone: 412.968.0100 Fax: 412.968.5415

BENSHAW Canada

550 Bright Street East Listowel, Ontario N4W 3W3

Phone: 519.291.5112 Fax: 519.291.2595

BENSHAW Pueblo

1 Jetway CourtPueblo, CO 81001

Phone: 719.948.1405Fax: 719.948.1445

BENSHAW China

No. 3 Quanhui RoadWuqing Development AreaTianjin City, China 301700

Phone: +86 22 8216 6100Fax: +86 22 8216 6160

BENSHAW Mexico

Ave. E #571Parque Industrial MartelApodaca, NL, Mexico 66637

Phone: +52 (81) 8244 5360Fax: +52 (81) 8244 5360 x209

Specifications are subject to change without notice.© 2012 Curtiss-Wright Flow Control Corporation.

24/7 Technical SupportBenshaw is dedicated to providing comprehensive 24-hour-a-day, 7-day-a-week phone support. Benshaw provides repair, spare parts, field engineering, retrofit, and training services, when and where you need us. You can count on our experienced team, backed by the latest diagnostics and repair tools and an extensive parts inventory to support your operations. Call 1.800.203.2416

24/7 Hotline Support from our operations in Pittsburgh and Listowel (Canada):

•Technical phone support • Overnight parts shipment • 24-hour service dispatch • Coordination of all service capabilities

RepairsRepairs are made on Benshaw equipment by trained, experienced personnel, using the latest diagnostic and test equipment.

Field Services are performed on-site by skilled technicians, engineers, or complete teams if needed, including:

• Start-up commissioning• Field repairs• Field analysis/data collection• Preventative maintenance

The Benshaw Product LineA wide range of motor controls and drives are available.

• Solid state starters fractional up to 30,000 HP at 15 kV • LV AC drives to 700 HP, MV AC drives to 3,000 HP • Electromechanical controls to 800 A

Benshaw Express is a 24/7 online inventory and order entry system for authorized Benshaw distributors:

• 24/7 shipment• Either air or truck delivery